This document set includes construction drawings and specifications for infrastructure upgrades at the Bonham VA Medical Center in Bonham, Texas. The project involves renovations and repairs to buildings 1, 2, 3, 4, 8, 9, 10, 11, 12, 24, 29, and 34. Work includes upgrades to mechanical, electrical, plumbing, fire protection, and telecommunications systems. Infection control protocols are specified, requiring barriers and negative air containment for dust-generating activities. Drawings depict demolition plans, site utilities, structural details, architectural floor plans, and schematics for fire alarms, sprinklers and HVAC, electrical, telecom, and security systems. Consultants include Olsson for civil engineering and Spur Design for architectural/engineering services. The construction manager is ES2. The estimated award date is July 2023.
View the file
Other files
Show 40 more
Latest 50 of 70 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
CONSULTANTS:
U.S. DEPARTMENT OF VETERANS AFFAIRS
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC ENGINEER
SPUR DESIGN
2519 MADISON AVE., STE. 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TECH ENGINEER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STRUCT ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2023
ENGR REG. NO. F-17591 EXP. 02/29/2024
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
STAMP:
Drawing Number
Building Number
BUILDING 34 NOT SPRINKLERED. ALL OTHER BUILDINGS FULLY SPRINKLERED.
COMMISSIONING
ES2
13401 N. SANTA FE AVE
OKLAHOMA CITY, OK 73114
(405) 528-4500
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
C U
I)
/5
/2
:1
:0
A
M
100% BID DOCUMENTS
BONHAM EHRM INFRASTRUCTURE
UPGRADES
VA PROJECT NUMBER: 549A4-21-700
BONHAM VA MEDICAL CENTER
1201 E. 9TH STREET
BONHAM, TX 75418
100% BID DOCUMENTS
COVER SHEET
NSM 1 OF 229AJS
BONHAM EHRM
INFRASTRUCTURE
UPGRADES
07/07/2023
549A4-21-700
BONHAM VA MEDICAL CENTER
1201 E. 9TH STREET
BONHAM, TX 75418
GI000
SPUR #: 2216
NN
LOCATION
PLAN
AREA
PLAN
PROJECT LOCATION
B1
B29
B24
B2 B3
B4
B12
B11 B8
B34
B9B10
E 9TH ST
L Y
N N
S T
L
IP
S C
O M
B B
L V
D
E 8TH ST
E 7TH ST
E 10TH ST
E 11TH ST
E E
L M
S T
L Y
N N
S T
E 9TH ST
V E
TE
R
A N
S B
LV
D
SEVEN OAKS RD
1, 2, 3, 4, 8, 9, 10, 11, 12, 24, 29, & 34
No. REVISION DESCRIPTION DATE th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
CONSULTANTS:
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC ENGINEER
SPUR DESIGN
2519 MADISON AVE., STE. 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TECH ENGINEER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STRUCT ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2023
ENGR REG. NO. F-17591 EXP. 02/29/2024
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
STAMP:
Drawing Number
Building Number
BUILDING 34 NOT SPRINKLERED. ALL OTHER BUILDINGS FULLY SPRINKLERED.
COMMISSIONING
ES2
13401 N. SANTA FE AVE
OKLAHOMA CITY, OK 73114
(405) 528-4500
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
C U
I)
/5
/2
:1
:0
A
M
100% BID DOCUMENTS
SHEET INDEX
NSM 2 OF 229AJS
BONHAM EHRM
INFRASTRUCTURE
UPGRADES
07/07/2023
549A4-21-700
BONHAM VA MEDICAL CENTER
1201 E. 9TH STREET
BONHAM, TX 75418
GI001
SPUR #: 2216
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[01] GENERAL
1 GI000 COVER SHEET
2 GI001 SHEET INDEX
3 GI002 GENERAL INFORMATION
4 GI003 ICRA CONSTRUCTION DETAILS
[02] HAZARDOUS MATERIALS
5 HA010 BUILDING 1 - BASEMENT - ENVIRONMENTAL HAZARDS
6 HA011 BUILDING 1 - FLOOR 1 - ENVIRONMENTAL HAZARDS
7 HA012 BUILDING 1 - FLOOR 2 - ENVIRONMENTAL HAZARDS
8 HA013 BUILDING 1 - FLOOR 3 - ENVIRONMENTAL HAZARDS
9 HA014 BUILDING 1 - FLOOR 4 - ENVIRONMENTAL HAZARDS
10 HA015 BUILDING 1 - FLOOR 5 - ENVIRONMENTAL HAZARDS
11 HA021 BUILDING 2 - FLOOR 1 - ENVIRONMENTAL HAZARDS
12 HA022 BUILDING 2 - FLOOR 2 - ENVIRONMENTAL HAZARDS
13 HA023 BUILDING 2 - FLOOR 3 - ENVIRONMENTAL HAZARDS
14 HA024 BUILDING 2 - FLOOR 4 - ENVIRONMENTAL HAZARDS
15 HA031 BUILDING 3 - FLOOR 1 - ENVIRONMENTAL HAZARDS
16 HA032 BUILDING 3 - FLOOR 2 - ENVIRONMENTAL HAZARDS
17 HA041 BUILDING 4 - ENVIRONMENTAL HAZARDS
18 HA081 BUILDING 8 - ENVIRONMENTAL HAZARDS
19 HA091 BUILDING 9 - ENVIRONMENTAL HAZARDS
20 HA101 BUILDING 10 - FLOOR 1 - ENVIRONMENTAL HAZARDS
21 HA111 BUILDING 11 - FLOOR 1 - ENVIRONMENTAL HAZARDS
22 HA121 BUILDING 12 - FLOOR 1 - ENVIRONMENTAL HAZARDS
23 HA122 BUILDING 12 - FLOOR 2 - ENVIRONMENTAL HAZARDS
24 HA123 BUILDING 12 - ROOF - ENVIRONMENTAL HAZARDS
25 HA241 BUILDING 24 - ROOF - ENVIRONMENTAL HAZARDS
26 HA291 BUILDING 29 - ENVIRONMENTAL HAZARDS
27 HA340 BUILDING 34 - FLOOR 1 - ENVIRONMENTAL HAZARDS
[03] CIVIL
28 GS001 GENERAL LAYOUT PLAN
29 GS002 OVERALL SITE AND DEMOLITION PLAN
30 GS003 SITE AND DEMOLITION PLAN 1
31 GS004 SITE AND DEMOLITION PLAN 2
32 GS005 SITE AND DEMOLITION PLAN 3
33 GS006 SITE AND DEMOLITION PLAN 4
34 GS007 GRADING PLAN 1
35 GS008 GRADING PLAN 2
36 GS009 GRADING PLAN 3
37 GS010 GRADING PLAN 4
38 GS011 UTILITY PLAN 1
39 GS012 UTILITY PLAN 2
40 GS013 UTILITY PLAN 3
41 GS014 UTILITY PLAN 4
42 GS015 EROSION CONTROL PLAN 1
43 GS016 EROSION CONTROL PLAN 2
44 GS017 EROSION CONTROL PLAN 3
45 GS018 EROSION CONTROL PLAN 4
46 GS019 EROSION CONTROL DETAILS
47 GS020 DETAILS
[04] STRUCTURAL
48 S-001 STRUCTURAL GENERAL NOTES
49 S-201 BUILDING 1 ROOF PLAN
50 S-202 BUILDINGS 2 & 3 ROOF PLANS
51 S-203 BUILDINGS 4, 9, 10 & 12 ROOF PLANS
52 S-204 BUILDING 24 ROOF PLAN
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[05] ARCHITECTURAL
53 A-101 BUILDING 1 - REFERENCE PLANS
54 A-102 BUILDING 1 - REFERENCE PLANS
55 A-103 BUILDING 2 - REFERENCE PLANS
56 A-104 BUILDING 2 - REFERENCE PLANS
57 A-105 BUILDINGS 3, 4, 8, & 9 - REFERENCE PLANS
58 A-106 BUILDINGS 10, 11, & 12 - REFERENCE PLANS
59 A-107 BUILDING 24 - REFERENCE PLAN
60 A-108 BUILDING 24 - REFERENCE PLAN
61 A-109 BUILDING 29 - REFERENCE PLAN
62 AE101 BLDG 1 - BASEMENT - ENLARGED PLANS
63 AE102 BLDG 1 - LEVEL ONE - ENLARGED PLANS
64 AE103 BLDG 1 - LEVEL TWO, LEVEL THREE, & LEVEL FOUR - ENLARGED PLANS
65 AE104 BLDG 1 - LEVEL FIVE - ENLARGED PLANS
66 AE105 BLDG 2 - LEVEL ONE & LEVEL TWO - ENLARGED PLANS
67 AE106 BLDG 2 - LEVEL TWO, LEVEL THREE, & LEVEL FOUR - ENLARGED PLANS
68 AE107 BLDG 2 - LEVEL FOUR, BLDG 3 - ENLARGED PLANS
69 AE108 BLDG 4 & 8 - ENLARGED PLANS
70 AE109 BLDG 9 & 10 - ENLARGED PLANS
71 AE110 BLDG 11 & 12 - ENLARGED PLANS
72 AE111 BLDG 24 - LEVEL ONE - ENLARGED PLANS
73 AE112 BLDG 24 - LEVEL TWO - ENLARGED PLANS
74 AE113 BLDG 29 - ENLARGED PLANS
75 AE601 DOOR SCHEDULE & DETAILS
76 AF711 PARTITION, FINISH SCHEDULES & DETAILS
[06] FIRE PROTECTION
77 FA001 FIRE ALARM NOTES MATRIX AND RISER DIAGRAM
78 FA101 BUILDING 1 - REFERENCE PLANS
79 FA102 BUILDING 1 - REFERENCE PLANS
80 FA103 BUILDING 2 - REFERENCE PLANS
81 FA104 BUILDING 2 - REFERENCE PLANS
82 FA105 BUILDINGS 3, 4, 8, & 9 - REFERENCE PLANS
83 FA106 BUILDINGS 10, 11, 12, & 34 - REFERENCE PLANS
84 FA107 BUILDING 24 - REFERENCE PLAN
85 FA108 BUILDING 24 - REFERENCE PLAN
86 FA109 BUILDING 29 - REFERENCE PLAN
87 FA401 BLDG 1 - BASEMENT - ENLARGED PLANS
88 FA402 BLDG 1 - ENLARGED PLANS
89 FA403 BLDG 2 & 3 - ENLARGED PLANS
90 FA404 BLDG 4 & 8 - ENLARGED PLANS
91 FA405 BLDG 9 & 10 - ENLARGED PLANS
92 FA406 BLDG 24 - ENLARGED PLANS
93 FA407 BLDG 29 - ENLARGED PLANS
94 FA500 FIRE ALARM DETAILS
95 FX001 FIRE SPRINKLER NOTES
96 FX101 BUILDING 1 - REFERENCE PLANS
97 FX102 BUILDING 1 - REFERENCE PLANS
98 FX103 BUILDING 2 - REFERENCE PLANS
99 FX104 BUILDING 2 - REFERENCE PLANS
100 FX105 BUILDINGS 3, 4, 8, & 9 - REFERENCE PLANS
101 FX106 BUILDINGS 10, 11, 12, & 34 - REFERENCE PLANS
102 FX107 BUILDING 24 - REFERENCE PLAN
103 FX108 BUILDING 24 - REFERENCE PLAN
104 FX109 BUILDING 29 - REFERENCE PLAN
105 FX401 BLDG 1 - BASEMENT - ENLARGED PLANS
106 FX402 BLDG 1 - ENLARGED PLANS
107 FX403 BLDG 2 & 3 - ENLARGED PLANS
108 FX404 BLDG 4 & 8 - ENLARGED PLANS
109 FX405 BLDG 9 & 10 - ENLARGED PLANS
110 FX406 BLDG 24 - ENLARGED PLANS
111 FX407 BLDG 29 - ENLARGED PLANS
112 FX500 FIRE SPRINKLER DETAILS
BONHAM EHRM INFRASTRUCTURE
UPGRADES
VA PROJECT NUMBER: 549A4-21-700
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[07] MECHANICAL
113 M-000 LEGEND AND ABBREVIATIONS
114 M-101 BUILDING 1 HVAC REFERENCE PLANS
115 M-102 BUILDING 1 HVAC REFERENCE PLANS
116 M-103 BUILDING 2 HVAC REFERENCE PLANS
117 M-104 BUILDING 2 HVAC REFERENCE PLANS
118 M-105 BUILDING 3 HVAC REFERENCE PLANS
119 M-106 BUILDING 4, 8, 9, 10, 11, 12, & 34 HVAC REFERENCE PLANS
120 M-107 BUILDING 24 HVAC REFERENCE PLANS
121 M-108 BUILDING 24 HVAC REFERENCE PLANS
122 M-109 BUILDING 29 HVAC REFERENCE PLANS
123 M-201 BUILDING 1 HVAC ROOF PLAN
124 M-202 BUILDING 2 & 3 HVAC ROOF PLANS
125 M-203 BUILDING 4, 9, 10, & 12 HVAC ROOF PLANS
126 M-204 BUILDING 24 HVAC ROOF PLAN
127 M-401 BUILDING 1 HVAC ENLARGED PLANS
128 M-402 BUILDING 1 HVAC ENLARGED PLANS CONTINUED
129 M-403 BUILDING 2 HVAC ENLARGED PLANS
130 M-404 BUILDING 2, 3, & 4 HVAC ENLARGED PLANS CONTINUED
131 M-405 BUILDING 8, 9, 10, 11, & 12 HVAC ENLARGED PLANS
132 M-406 BUILDING 24 HVAC ENLARGED PLANS
133 M-407 BUILDING 29 HVAC ENLARGED PLANS
134 M-501 MECHANICAL DETAILS
135 M-502 MECHANICAL DETAILS
136 M-601 MECHANICAL SCHEDULES
137 M-701 MECHANICAL CONTROLS
[08] ELECTRICAL
138 E-001 ELECTRICAL LEGEND AND ABBREVIATIONS
139 E-101 BUILDING 1 - REFERENCE PLANS
140 E-102 BUILDING 1 - REFERENCE PLANS
141 E-103 BUILDING 2 - REFERENCE PLAN
142 E-104 BUILDING 2 - REFERENCE PLAN
143 E-105 BUILDINGS 3, 4, 8, & 9 - REFERENCE PLANS
144 E-106 BUILDINGS 10, 11, 12, & 34 - REFERENCE PLANS
145 E-107 BUILDING 24 - REFERENCE PLAN
146 E-108 BUILDING 24 - REFERENCE PLAN
147 E-109 BUILDING 29 - REFERENCE PLAN
148 E-201 BUILDING 1 - ROOF PLANS
149 E-202 BUILDINGS 2 & 3 - ROOF PLANS
150 E-203 BUILDINGS 4, 8, 9, 10, & 12 - ROOF PLANS
151 E-204 BUILDING 24 - ROOF PLANS
152 E-401 BLDG 1 - BASEMENT ELECTRICAL ROOM - ENLARGED PLANS
153 E-402 BLDG 1 - BASEMENT - ENLARGED PLANS
154 E-403 BLDG 1 - LEVEL ONE - ENLARGED PLANS
155 E-404 BLDG 1 - LEVELS TWO, THREE, AND FOUR - ENLARGED PLANS
156 E-405 BLDG 1 - LEVEL FIVE - ENLARGED PLAN
157 E-406 BLDG 2 - LEVELS ONE AND TWO - ENLARGED PLANS
158 E-407 BLDG 2 - LEVELS TWO, THREE, AND FOUR - ENLARGED PLANS
159 E-408 BLDG 3 - LEVEL FOUR - ENLARGED PLANS
160 E-409 BLDG 4 & 8 - ENLARGED PLANS
161 E-410 BLDG 9 & 10 - ENLARGED PLANS
162 E-411 BLDG 11 & 12 - ENLARGED PLANS
163 E-412 BLDG 24 - LEVEL ONE - ENLARGED PLANS
164 E-413 BLDG 24 - LEVEL TWO - ENLARGED PLANS
165 E-414 BLDG 29 - ENLARGED PLANS
166 E-415 BLDG 1, 2, & 3 - ENLARGED MECHANICAL POWER PLANS
167 E-416 BLDG 4, 8, 9, 10, 12, & 24 - ENLARGED MECHANICAL POWER PLANS
168 E-501 ELECTRICAL DETAILS
169 E-502 ELECTRICAL DETAILS
170 E-503 ELECTRICAL DETAILS
171 E-504 ELECTRICAL DETAILS
172 E-601 BUILDING 1 - ELECTRICAL ONE-LINE DIAGRAM
173 E-602 BUILDING 2 - ELECTRICAL ONE-LINE DIAGRAM
174 E-603 BUILDING 3 & 4 - ELECTRICAL ONE-LINE DIAGRAM
175 E-604 BUILDING 8 - ELECTRICAL ONE-LINE DIAGRAM
176 E-605 BUILDING 9, 10, 11, & 12 - ELECTRICAL ONE-LINE DIAGRAM
177 E-606 BUILDING 24 - ELECTRICAL ONE-LINE DIAGRAM
178 E-607 BUILDING 29 - ELECTRICAL ONE-LINE DIAGRAM
179 E-701 BUILDING 1 & 2 - PANEL SCHEDULES
180 E-702 BUILDING 2, 3 & 4- PANEL SCHEDULES
181 E-703 BUILDING 9, 10, 12, & 24 - PANEL SCHEDULES
182 E-704 BUILDING 29 - PANEL SCHEDULES
183 E-705 ELECTRICAL SCHEDULES
1, 2, 3, 4, 8, 9, 10, 11, 12, 24, 29, & 34
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[09] TELECOMMUNICATION
184 T-000 TELECOM SYMBOLS & ABBREVIATIONS
185 T-100 BUILDING 1 - TELECOM PLANS
186 T-101 BUILDING 1 - TELECOM PLANS
187 T-102 BUILDING 2 - TELECOM PLANS
188 T-103 BUILDING 2 - TELECOM PLANS
189 T-104 BUILDING 3, 4, 8 & 9 - TELECOM PLANS
190 T-105 BUILDING 10, 11, 12 & 34 - TELECOM PLANS
191 T-106 BUILDING 24 - TELECOM PLANS
192 T-107 BUILDING 24 - TELECOM PLANS
193 T-108 BUILDING 29 - TELECOM PLANS
194 T-200 TELECOM SITE PLANS
195 T-201 TELECOM BACKBONE PATHWAYS - BLDG 2, 3, 10, 24 & 4
196 T-202 TELECOM BACKBONE PATHWAYS - BLDG 8, 9, 11, 12 & 29
197 T-203 RISER DIAGRAM - BUILDING 1 FIBER OPTIC BACKBONE
198 T-204 RISER DIAGRAM - CAMPUS FIBER BACKBONE 'A' & 'B'
199 T-300 BUILDING 1 - TELECOM ENLARGED PLANS
200 T-301 BUILDING 1 - TELECOM ENLARGED PLANS
201 T-302 BUILDING 1 - TELECOM ENLARGED PLANS
202 T-303 BUILDING 2 - TELECOM ENLARGED PLANS
203 T-304 BUILDING 2, 3, 4 & 8 - TELECOM ENLARGED PLANS
204 T-305 BUILDING 9, 10, 11 & 12 - TELECOM ENLARGED PLANS
205 T-306 BUILDING 24 - TELECOM ENLARGED PLANS
206 T-307 BUILDING 29 - TELECOM ENLARGED PLANS
207 T-400 TELECOM DETAILS
208 T-401 TELECOM TR DETAILS
209 T-402 TELECOM MCR DETAILS
[10] SECURITY
210 TY000 ABBREVIATIONS, SYMBOLS, LEGENDS & NOTES
211 TY101 BUILDING 1 - REFERENCE PLANS
212 TY102 BUILDING 1 - REFERENCE PLANS
213 TY103 BUILDING 2 - REFERENCE PLAN
214 TY104 BUILDING 2 - REFERENCE PLAN
215 TY105 BUILDINGS 3, 4, 8, & 9 - REFERENCE PLANS
216 TY106 BUILDINGS 10, 11, & 12 - REFERENCE PLANS
217 TY107 BUILDING 24 - REFERENCE PLAN
218 TY108 BUILDING 24 - REFERENCE PLAN
219 TY109 BUILDING 29 - REFERENCE PLAN
220 TY400 BLDG 1 - SECURITY ENLARGED PLANS
221 TY401 BLDG 1 - SECURITY ENLARGED PLANS
222 TY402 BLDG 1 - SECURITY ENLARGED PLANS
223 TY403 BLDG 2 - SECURITY ENLARGED PLANS
224 TY404 BLDG 3, 4, 8 - SECURITY ENLARGED PLANS
225 TY405 BLDG 9, 10, 11, 12 - SECURITY ENLARGED PLANS
226 TY406 BLDG 24 - SECURITY ENLARGED PLANS
227 TY407 BLDG 29 - SECURITY ENLARGED PLANS
228 TY500 SECURITY DETAILS
229 TY600 SECURITY RISERS AND DIAGRAMS
TOTAL SHEETS: 229
100% BID DOCUMENTS
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
4' -0
M
A X
4' -0
M
A X
2' -1
0" M
A X
2' -3
M
IN
1'-6" MIN
1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS @ 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
VA TOILET ROOM
TURNING RADIUS
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4' -0
"M A
X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4' -0
M
A X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3' -4
"M A
X
17 MIN
2' -3
M
IN
3' -0
M
A X
1'-6" MIN
WALL
2' -9
" 4' -0
M
IN
2'-0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1' -5
M
A X
1'-6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5'-6"
CLEAR FLOOR
6'-0"
3'-0" MIN
2' -9
3' -0
1'-0" MIN
3'-6" MIN 1'-0"MAX
4'-6" MIN
1' -5
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2' -9
'-0
WALL
WALL
4' -0
M
A X
WALL HOOK
7' -0
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
4' -0
"M A
X
4' -0
M
A X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
CLEAR FLOOR SPACE
@ WATER CLOSET
5'-6"
2'-6"
4' -0
2'-6"
4' -0
HANDRAILS AND
BUMPER GUARDS
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN48
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN
*4 8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS
SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2021 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)
• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2021 NATIONAL FIRE CODES (NFPA)
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2020 VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• 2021 INTERNATIONAL MECHANICAL CODE
• 2020 NATIONAL ELECTRICAL CODE (NEC), NFPA 70
• 2021 INTERNATIONAL PLUMBING CODE (IPC)
• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2017 ANSI ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND
NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT
NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.
DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES
EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
ASHRAE 90.1 - 2019 EDITION
BUILDING LOCATION: BONHAM, TEXAS
CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 3A
INTERIOR DESIGN CONDITIONS:
THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM
AND MINIMUM VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.
BUILDING ENVELOPE REQUIREMENTS (5.5 )
BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)
ROOFS REQUIRED DESIGNED
INSULATION: R-30 c.i. EXISTING METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls EXISTING
ATTIC AND OTHER: R-49 EXISTING
WALLS, ABOVE GRADE
MASS: R-9.5 c.i. EXISTING METAL BUILDING: R-0 + R-15.8 c.i. EXISTING STEEL-FRAMED: R-13 + R-7.5 c.i. EXISTING WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 EXISTING
WALL, BELOW GRADE
BELOW-GRADE WALL: R-7.5 c.i. EXISTING
FLOORS
MASS: R-14.6 c.i. EXISTING
STEEL-FRAMED: R-30 EXISTING
WOOD-FRAMED AND OTHER: R-30 EXISTING
SLAB-ON-GRADE FLOORS
UNHEATED SLABS: R-15 for 24 in. EXISTING HEATED SLABS: R-20 for 24 in. EXISTING
OPAQUE DOORS
SWINGING: U-0.370 EXISTING
NONSWINGING: U-0.310 EXISTING
FENESTRATION (TABLE 5.5-4):
VERTICAL FENESTRATION, U-FACTOR
FIXED: U-0.36 EXISTING
OPERABLE: U-0.45 EXISTING
ENTRANCE DOOR: U-0.63 EXISTING
DEFINITIONS
c.i = CONTINUOUS INSULATION Ls = LINEAR SYSTEM
NR = NO (INSULATION) REQUIREMENT
ENERGY REQUIREMENTS
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL
CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE
ENTIRE DOCUMENT SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY
WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY
ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT
CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE
CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK
AREAS FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN
PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED
OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE
OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT
PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE
ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER
DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A
WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE
AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND
ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS,
BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL
DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE
OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION
DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND
OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND
SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL
SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE
DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO
THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH
SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN
ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,
EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR
INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60
CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS
DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER
MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE
THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS
REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED,
IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME
SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF
THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY
OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE
INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN
ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY
AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING
THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR
DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING
BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE
DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION
DOCUMENTS.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
A
00.0
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00" 4B
3A
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
CLEAN UTILITY
000A
150 SF / 100 SF
/1 A101
X0000
6"
3' -0
M
A X
ROOM TAG
TOTAL SQUARE FEET/
REQUIRED MIN. SQUARE FEET
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
A
ACB ACOUSTIC CEILING BAFFLE
ACP ACOUSTIC CEILING PANEL
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM (TRIM)
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AT ACOUSTIC CEILING TILE
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CBB CONCRETE BACKER BOARD
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CH BD CHALK BOARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CP/CI CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CPT CARPET/CARPET TILE
CS CONCRETE SEALED
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DIMENSIONAL WALL PANEL
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPY EPOXY FLOORING
EQ EQUAL
ETR EXISTING TO REMAIN
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FAB FABRIC
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FP FIRE PROTECTION
FR FIRE RESISTANT
FT FEET
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G
GDR GUARDRAIL
GL GLASS/GLAZING
GRAN GRANITE
GR FL GROUND FLOOR
GT GROUT
GSM GALVANIZED SHEET METAL
GYP BD GYPSUM BOARD
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LN LINOLEUM
LOC LOCATION
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAT CARPET MAT / WALK-OFF MAT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P
P PAINT
PA PUBLIC ADDRESS
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRB PROFILE BASE
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'- 0"
5'- 6"
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE @ ADA
DRINKING FOUNTAIN
4"
6"
3"
6" 1'
-6
6" MAX
7" - 9" 11" MIN
17" - 25"
M
IN
6' -0
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3' -6
M
A X
5' -0
M
A X
R
RAF RESILIENT ATHETIC FLOORING
RB RUBBER BASE/RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RES RESINOUS FLOORING
RES-W RESINOUS / EPOXY WALL / CEILING
RF RUBBER FLOORING
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RSF RESILIENT SHEET FLOORING
RV ROOF VENT
RWC RIGID VINYL WALLCOVERING
S
SC SPECIALTY COATING
SD STATIC DISSIPATIVE FLOORING/TILE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SOLID SURFACE
ST STONE
STD STANDARD
STOR STORAGE
SV SHEET VINYL (ROLLED OR TILE)
T
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
VC VA PROVIDED / CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL FACED ACOUSTICAL TILE
VP VENEERED PLASTER
VT VINYL TILE
VV VA PROVIDED / VA INSTALLED
VWC VINYL WALLCOVERING
VWF VINYL WALL FABRIC
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WD WOOD
WFAB WALL FABRIC
WPM WATERPROOF MEMBRANE
WSF WELDED SHEET FLOOR
X
X BRACE CROSS BRACE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
CONSULTANTS:
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC ENGINEER
SPUR DESIGN
2519 MADISON AVE., STE. 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TECH ENGINEER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STRUCT ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2023
ENGR REG. NO. F-17591 EXP. 02/29/2024
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
STAMP:
Drawing Number
Building Number
BUILDING 34 NOT SPRINKLERED. ALL OTHER BUILDINGS FULLY SPRINKLERED.
COMMISSIONING
ES2
13401 N. SANTA FE AVE
OKLAHOMA CITY, OK 73114
(405) 528-4500
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
C U
I)
/5
/2
:1
:0
A
M
100% BID DOCUMENTS
GENERAL INFORMATION
NSM 3 OF 229AJS
BONHAM EHRM
INFRASTRUCTURE
UPGRADES
07/07/2023
549A4-21-700
BONHAM VA MEDICAL CENTER
1201 E. 9TH STREET
BONHAM, TX 75418
GI002
SPUR #: 2216
OUTSIDE OF BUILDING
WEEKLY CHANGED HEPA FILTER
HEPA NEGATIVE AIR UNIT
WEEKLY CHANGED (OR
MORE AS NEEDED) PRE-
FILTER
FIRE RATED PLYWOOD
F
LE
X D
U C
T
SUPPLY DUCTS EITHER KEEP
RUNNING OR COVER WHEN
RUNNING TO KEEP DUST OUT.
TAPE ALL SERVICES
TO PROTECT AGAINST
CONTAMINATION A
O
VFIRE EXTINGUISHER ON PORTABLE
FLOOR BRACKET (ILSM MAY
REQUIRE MORE THAN ONE)
SUSPENDED PLASTIC
ZIPPER WALL CURTAIN
BARRIER 6 MIL PLASTIC
TEMPORARY DIGITAL MANOMETER FOR NEGATIVE PRESSURE
MONITORING OUTSIDE OF ICRA BARRIER FOR VA'S INSPECTION.
INDICATOR SHALL BE AT -0.01 OR GREATER (VERIFY DAILY). IF NOT,
VERIFY ALL OPENINGS, SUCH AS DOOR CLOSED, AND/OR CHANGE OUT
NEGATIVE AIR PRE-FILTER.
PROVIDE STICKY MAT, DRY MAT, WET MAT (CHANGED END OF
SHIFT OR MORE IF NECESSARY TO MAINTAIN CLEANLINESS)
PROVIDE WIPES AND SPRAY FOR WET MAT
POST ICRA ILSM FIRE
INSPECTION SHEETS
CONTAINER VISIBLE TO PUBLIC
COVER ALL RETURNS AT THE
GRATE/DIFFUSERS
OPTIONAL EXHAUST DUCTS
(COVER THE GRATES AND THE DIFFUSERS)
E
DOOR OPENING
VENT TO OUTSIDE ROUTE
TO BE APPROVED BY COR.
FIRE PULL STATION WITH
AUDIO/ VISUAL
ILSM SIGNAGE
ICRA BARRIER, SEE PLANS FOR TYPE AND LOCATION
GI003
GI003
PLASTIC WINDOW
SWIVEL CASTERS
WITH TWO LOCKING
BRAKES
MOBILE CART
A D
JU
S
T A
B
LE
H E
IG
H
T
HEPA NEGATIVE AIR
UNIT
EXISTING WALL
EXISTING CEILING
FLEX DUCT
HEATED DETECTOR CUT-OFF
BASIS OF DESIGN: HEPA NEGATIVE AIR
UNIT INTEGRAL WITH EDGEGUARD
BARRIER SYSTEM.
FIRE RATED PLYWOOD (TEMP.
REMOVE GLASS PANEL)
EXISTING WINDOW FRAME
TYPE A OR C ICRA BARRIER, SEE
PLANS FOR TYPE AND LOCATION
TYPE B OR D ICRA
BARRIER, SEE PLANS FOR
TYPE AND LOCATION
EXISTING CEILING
EXISTING CONCRETE SLAB FLOORING
FINISHED FLOORING TO BE KEPT
CLEAN. FLOORS NOT BEING
REPLACED MUST BE PROTECTED.
COVER WITH ROSIN PAPER/ FIRE
RATED PLYWOOD.
WHEN WORKING ABOVE CEILING
WITH BARRIERS THAT
TERMINATE AT CEILING,
PROVIDE PLASTIC ENCLOSURE
IN PLENUM SPACE.
AREA UNDER CONSTRUCTION
PERSONNEL ENTERING MUST HAVE: HARD HAT,
SAFETY GLASSES AND PROPER I.D.
--DESCRIPTION ON NEWLY PROPOSED OCCUPANCY--
COMING SOON!!!
XXXXXX
XXXXXX
XXXXXX
POST ICRA, ILSM, FIRE
INSPECTION SHEETS VISIBLE
TO THE PUBLIC
SUSPENDED PLASTIC ZIPPER
WALL CURTAIN BARRIER
INDICATOR MUST MAINTAIN -0.01 INCHES OR MORE
NEGATIVE (VERIFY DAILY), IF NOT VERIFY ALL
OPENINGS SUCH AS DOORS ARE CLOSED AND/OR
CHNAGE OUT NEGATIVE AIR PRE-FILTER.
4' -0
"A .F
.F
ICRA, ISLM, FIRE
WATCH, MISC. FORMS
PAPER CADDY
INDICATOR (REFER TO PLAN
AND ELEVATION) FRAMED PICTURE
OF C.O.R. WITH
CONTACT
INFORMATION
CONSTRUCTION SUPERVISOR
NAME AND CELL PHONE
XXXXX
BOILER/CHILLER PLANT AFTER
HOURS CONTACT PHONE XXXXX
FIRE EMERGENCY DIAL 911
THIS IS A RESTRICTED AREA
3 5/8" INSULATED WALL WITH 16
GAUGE METAL STUDS @ 16" O.C.
(2) LAYERS 5/8" GYPSUM BOARD
EACH SIDE. WALL TO EXTEND TO
UNDERSIDE OF DECK
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
EXISTING CEILING SYSTEM
BASE - TO MATCH EXISTING
AREA
EXISTING FLOOR
UNDERSIDE OF EXISTING DECK
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L D
V E
R
IF
Y
W A
L L
H E
IG
H
T V
A R
IE
S
F
IE
L D
V E
R
IF
Y
6 1/8"
D
FIRE RESISTANT SEALANT, BOTH
SIDES
2-HR RATED AND SMOKE
RATED
U.L. DESIGN NO. U404A
PLASTIC SHEET BARRIER
NON RATED
PLASTIC SHEET
BARRIER
EXISTING WALL
ASSEMBLY
EXISTING
CEILING
BOTTOM SEALING RUNNER
TOP SEALING
RUNNER
SUPPORT POLES,
QUANTITY PER MANUF.
RECOMMENDATIONS
REQU.
AS
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
EXISTING CEILING SYSTEM
BASE - TO MATCH EXISTING
AREA
EXISTING FLOOR
UNDERSIDE OF EXISTING DECK
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L D
V E
R
IF
Y
/2
4 7/8"
3 5/8" 16 GAUGE METAL STUDS @
16" O.C. WALL TO EXTEND TO
UNDERSIDE OF DECK
B
FIRE RESISTANT SEALANT, BOTH
SIDES
SMOKE RATED
3 5/8" INSULATED WALL WITH 16
GAUGE METAL STUDS @ 16" O.C.
WALL TO EXTEND TO UNDERSIDE
OF DECK
5/8" FIRE RESISTANT GYPSUM
BOARD - BOTH SIDES
EXISTING CEILING SYSTEM
BASE - TO MATCH EXISTING
AREA
EXISTING FLOOR
UNDERSIDE OF EXISTING DECK
C E
IL
IN
G H
E
IG
H T
V A
R
IE
S F
IE
L D
V E
R
IF
Y
W A
L L
H E
IG
H
T V
A R
IE
S
F
IE
L D
V E
R
IF
Y
4 7/8"
C
FIRE RESISTANT SEALANT, BOTH
SIDES
1-HR RATED AND SMOKE RATED
U.L. DESIGN NO. U404
MATRIX OF PRECAUTIONS FOR CONSTRUCTION & RENOVATION
INSPECTION AND NON-INVASIVE ACTIVITIES
INCLUDES BUT NOT LIMITED TO:
• REMOVAL OF CEILING TILES FOR VISUAL INSPECTION LIMITED TO 1 TILE PER 50 SQUARE FEET.
• PAINTING (BUT NOT SANDING).
• WALL COVERING, ELECTRICAL TRIM, MINOR PLUMBING AND ACTIVITIES WHICH DO NOT GENERATE DUST OR
REQUIRE CUTTING OF WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL INSPECTION.
TYPE A
SMALL SCALE, SHORT DURATION ACTIVITIES WHICH CREATES MINIMAL DUST
INCLUDES BUT NOT LIMITED TO:
• INSTALLATION OF TELEPHONE AND COMPUTER CABLING.
• ACCESS TO CHASE SPACES.
• CUTTING OF WALLS OR CEILING WHERE DUST MIGRATION CAN BE CONTROLLED.
TYPE B
WORK THAT GENERATES A MODERATE TO HIGH LEVEL OF DUST OR REQUIRES DEMOLITION OR REMOVAL OF
ANY FIXED BUILDING COMPONENTS OR ASSEMBLIES
INCLUDES BUT NOT LIMITED TO:
• SANDING OF WALLS FOR PAINTING OR WALL COVERING.
• REMOVAL OF FLOOR COVERINGS, CEILING TILES OR CASEWORK.
• NEW WALL CONSTRUCTION.
• MINOR DUCT WORK OR ELECTRICAL WORK ABOVE CEILINGS.
• MAJOR CABLING ACTIVITIES.
• ANY ACTIVITY WHICH CANNOT BE COMPLETED WITHIN A SINGLE WORK SHIFT.
TYPE C
MAJOR DEMOLITION AND CONSTRUCTION PROJECTS
INCLUDES BUT NOT LIMITED TO:
• ACTIVITIES WHICH REQUIRE CONSECUTIVE WORK SHIFTS.
• REQUIRES HEAVY DEMOLITION OR REMOVAL OF A COMPLETE CABLING SYSTEM.
• NEW CONSTRUCTION.
TYPE D
PATIENT RISK GROUPS
LOW RISK MEDIUM RISK HIGH RISK HIGHEST RISK
• OFFICE AREAS • CARDIOLOGY
• ECHOCARDIOGRAPHY
• ENDOSCOPY
• NUCLEAR MEDICINE
• PHYSICAL THERAPY
• RADIOLOGY/MRI
• RESPIRATORY THERAPY
• CCU
• EMERGENCY ROOM
• LABOR & DELIVERY
• LABORATORY (SPECIMEN)
• NEWBORN NURSERY
• OUTPATIENT SURGERY
• PEDIATRICS
• PHARMACY
• POST ANESTHESIA CARE UNIT
• SURGICAL UNITS
• ANY AREA FOR IMMUNOCOMPROMISED PATIENTS
• BURN UNIT
• CARDIAC CATH LAB
• CENTRAL STERILE SUPPLY
• INTENSIVE CARE UNITS
• MEDICAL UNIT
• NEGATIVE PRESSURE ISOLATION ROOMS
• ONCOLOGY
• OPERATING ROOMS INCLUDING
• C-SECTION ROOMS
IC MATRIX - CLASS OF PRECAUTIONS:
CONSTRUCTION PROJECT BY PATIENT RISK
NOTE:
INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISK LEVEL INDICATE THAT CLASS III OR CLASS IV
CONTROL PROCEDURES ARE NECESSARY.
RISK RELATED GROUP
LOW RISK GROUP
MEDIUM RISK GROUP
HIGH RISK GROUP
HIGHEST RISK GROUP
TYPE A TYPE B TYPE C TYPE D
I
I
I
II III/IV IV
IV
IV
II
II
II
II
III
III/IV
III/IV
III/IV
INFECTION CONTROL RISK ASSESSMENT (ICRA)
CONSTRUCTION PROJECT TYPE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
CONSULTANTS:
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC ENGINEER
SPUR DESIGN
2519 MADISON AVE., STE. 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TECH ENGINEER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STRUCT ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2023
ENGR REG. NO. F-17591 EXP. 02/29/2024
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
STAMP:
Drawing Number
Building Number
BUILDING 34 NOT SPRINKLERED. ALL OTHER BUILDINGS FULLY SPRINKLERED.
COMMISSIONING
ES2
13401 N. SANTA FE AVE
OKLAHOMA CITY, OK 73114
(405) 528-4500
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C O
N T
R O
L L E
D U
N C
L A
S S
IF
IE
D I
N F
O R
M A
T
IO
N
C U
I)
/5
/2
:1
:0
A
M
100% BID DOCUMENTS
ICRA CONSTRUCTION DETAILS
NSM 4 OF 229AJS
BONHAM EHRM
INFRASTRUCTURE
UPGRADES
07/07/2023
549A4-21-700
BONHAM VA MEDICAL CENTER
1201 E. 9TH STREET
BONHAM, TX 75418
GI003
SPUR #: 2216
1/2" = 1'-0"
GENERAL ICRA CONSTRUCTION PLAN LAYOUT13/8" = 1'-0"
ICRA MOBILE CONTAINMENT CART23/8" = 1'-0"
SECTION AT ICRA CONSTRUCTION PLAN3
3/8" = 1'-0"
ICRA ELEVATION4
3/4" = 1'-0"
ICRA BARRIER WALL TYPES5
| Sheets |
| GI000 - COVER SHEET |
| GI001 - SHEET INDEX |
| GI002 - GENERAL INFORMATION |
| GI003 - ICRA CONSTRUCTION DETAILS |