Atch 7_621-24-103 drawing part 2 of 6.pdf
PDF 17 MB Posted
- Solicitation number
- 36C24926R0055
About this file
This document is a set of architectural bid drawings and schedules for the restoration of Building 35 (Theater) at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. The drawings are dated July 1, 2025, and were prepared by FFE (consultant) and Heapy (architect/engineer of record).
The project scope includes extensive interior restoration and renovation work across multiple levels of the theater building. Key construction elements include: new concrete and metal ramps with specific slope requirements (1:12); new metal and concrete stairs with detailed tread and riser dimensions; new wheelchair lift installations; platform construction at various levels with specific elevation callouts; new restroom facilities with porcelain tile finishes (Del Conca Faeteno hexagon mosaic in ivory, Item #104-977); hardwood floor refinishing and installation with stain matching (Miniwax Ebony MW 2718 and Fallen Cypress MW 425); dressing room and storage renovations; and stage apron restoration with solid oak wood finishing. The drawings specify extensive door and window restoration work, with detailed schedules for hardware finishes (satin brass clear coated and satin stainless steel), glazing specifications (1" IGU with UV-resistant and blackout films), and curtain installations (Fred Krieger Fabrics including IFR Epic Velour for auditorium and IFR Odyssey Velour for backstage). Paint finishes are specified as PPG Type 1 (Oatmeal), Type 2 (matching existing), and Type 3 (Starless Sky PPG0995-7). Solid surface countertops use Cambria Signature Series (Hermitage Polished) and Corian (Deep Nocturne). The project involves work across basement, stage level, first floor, back level 2, balcony level, projection booth, attic, and rafter areas, with comprehensive interior elevations, sections, and detail specifications for all finishes and fixtures.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ALIGN
S L O
P E
:1
S L O
P E
:1
AE322
AE322
CLEAR
3' - 6"
CLEAR
4' - 0"
RAMP
5' - 0"
RAMP
5' - 0"
R A
M P
R A
M P
L A
N D
IN
G
AE322
(4) TREADS AT 1' - 0" ±
4' - 0"
DN
3.063.06
3.05
3.05
3.04
5.14
5.14
1' - 0"
5.14
5.14
C.J.
C.J.
C.J.
E.J.
E.J. E.J.
C.J.
C.J.
E.J.
E.J.
5.32
01.1-STAGE
1717' - 6"
3.15
3.16
7.12
32.03
TYP
3.17
5.14
3.153.16
32.03
5.14
3.05
3.04
3.05
3.11
3.06
/4
"6
" 3
TYP
3.19
26.12
01.1-STAGE
1717' - 6"
32.03
3.16
3.15
3.17
3.11
5.14
3.11
7.10
TYP
3.19
01.1-STAGE
1717' - 6"
5.14
1' - 0"
(5
/2
R
IS
E R
S
32.03
3.15
3.16
3.17
(4) 1' - 0" TREADS ±
3.04
3.05
26.12
AE322
C L E
A R
/2
/2
(8) TREADS AT 11"
7' - 4"
LANDING
3' - 1 3/4"
CLEAR
2' - 7 1/2"
1' - 0"
5.185.19
TYP
5.25
5.26
01.1-STAGE
1717' - 6"
04.2-ATTIC
1756' - 0"
R
IS
E R
11" TREAD
5.19
5.18
(9
R
IS
E R
S A
T
(8) TREADS AT 11"
7' - 4" 1' - 0"
5.10
5.12
5.11
.0
3 3/4"
E Q
E Q
6.18
5.12
5.11
.0
5.10
9.41
9.41
AE322
5.10
5.11
5.127
TYP
27.01
6.21
4.16
5.24
5.12
5' - 0" 7' - 0"
7' - 0" 6' - 6"
5.10
4' - 0"3" ±
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:4
P M
AE322
ENLARGED RAMP AND STAIR PLAN
AND SECTION DETAILS
05/30/2025 SS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
1/2" = 1'-0"
ENLARGED PLAN AT NEW RAMP
1/4" = 1'-0"
SECTION DETAIL AT CONCRETE RAMP
1/4" = 1'-0"
SECTION DETAIL AT CONCRETE RAMP
1/4" = 1'-0"
SECTION DETAIL AT CONCRETE STAIR
1/2" = 1'-0"
ENLARGED PLAN AT NEW METAL STAIR
1/4" = 1'-0"
SECTION AT NEW METAL STAIR
DRAWING NOTES:
3.04 CONCRETE STAIR - SEE CIVIL DRAWINGS
3.05 CONCRETE SLAB OVER AGGREGATE BASE - SEE CIVIL DRAWINGS
3.06 CONCRETE RAMP - SEE CIVIL DRAWINGS
3.11 CONCRETE RAMP OVER AGGREGATE BASE - SEE CIVIL DRAWINGS
3.15 CONCRETE FOUNDATION WALL - COORDINATE WITH CIVIL AND STRUCTURAL DRAWINGS
3.16 CONCRETE FOOTING - COORDINATE WITH STRUCTURAL AND CIVIL DRAWINGS
3.17 CONCRETE FOUNDATIONS BEYOND
3.19 3/4" CONCRETE CHAMFER CORNER - TYPICAL ALL EXTERIOR CONCRETE WALL AND EXPOSED SLAB EDGES
4.16 TOOTH-IN BRICK AS NECESSARY AT NEW OPENING FOR MECHANICAL DUCTWORK - PROVIDE NEW STEEL LINTEL ABOVE
OPENING - SEE MECHANICAL DRAWINGS
5.10 PRE-ENGINEERED STEEL SHIPS LADDER. PAINT P-3. SECURE TO EXISTING AND NEW STRUCTURE - SEE FINISH LEGEND
AND STRUCTURAL DRAWINGS
5.11 METAL CATWALK - PAINT P-3 - SEE FINISH LEGEND
5.12 PRE ENGINEERED METAL GUARD RAIL AT 42" AFF. PAINT P-3 - SEE FINISH LEGEND
5.14 PREFINISHED BLACK GUARD WITH INTEGRAL HANDRAIL - HANDRAIL TO BE STAINLESS STEEL - SECURE TO NEW
CONCRETE RAMP / STAIR
5.18 PRE ENGINEERED METAL GRATE STAIR WITH INTEGRATED GUARD AND HANDRAIL. PAINT P-3 - SEE FINISH LEGEND AND
STRUCTURAL DRAWINGS
5.19 1 1/2" DIA. STEEL GUARD AT 42" AFF. WITH 1 1/2" DIA. STAINLESS STEEL HANDRAIL AT 36" AFF. - RAILING TO BE WELDED
TO TOP OF STEEL STAIR STRINGER. PAINT P-3 - SEE FINISH LEGEND
5.24 WALL LADDER - SECURE TO EXISTING STRUCTURE
5.25 METAL FRAMING FOR PRE ENGINEERED STAIR - SEE STRUCTURAL DRAWINGS
5.26 METAL SAFETY CHAIN WITH LOCK - ATTACH TO RAILING
5.32 1 1/2" DIA. STAINLESS STEEL HANDRAIL AT 36" A.F.F. - SECURE TO EXISTING MASONRY WALL
6.18 INFILL FLOOR TO MATCH EXISTING ADJACENT
6.21 INFILL FLOOR TO MATCH EXISTING ADJACENT BELOW
7.10 PERFORATED 4" DRAIN TILE WITH FABRIC SLEEVE - SEE CIVIL DRAWINGS
7.12 PERFORATED 4" DRAIN TILE WITH FABRIC SLEEVE BEYOND - SEE CIVIL DRAWINGS
9.41 PAINT MECHANICAL DUCTWORK P-3. TYPICAL ALL DUCTWORK AT STAGE - SEE FINISH LEGEND
26.12 EXTERIOR LIGHT FIXTURE - INSTALL IN SAME LOCATION AS DEMOLISHED FIXTURE - SEE ELECTRICAL DRAWINGS
27.01 RIGGING - SEE TECHNOLOGY DRAWINGS
32.03 EXTERIOR CONCRETE DRIVE. PHASE WORK IN COORDINATION WITH VA COR AND ACCESS REQUIREMENTS TO BUILDING
16 - SEE CIVIL DRAWINGS
1/4" = 1'-0"
ATTIC & CATWALK ENLARGED PLAN
BID DOCUMENTS 07/01/2025
125 SF
MEN'S
31 SF
TOILET
110A
110A
A4995
/2
C L
22.07
ALIGN
ALIGN
/4
/2
6' - 6" ±
T2
AE4101
2 SIM.
SIM.
P2
F1
F2
P2P1
AE411
MECHANICAL
110B
5' - 0"14' - 0" ±
5' - 0"
AE404
SIM.
3' - 6"
CL1' - 3"
T1 T1 P2
3' - 10 1/2"6" ±
22.11
T1 002
9.14
1' - 0"
/4
22.05
101A
AE410
SIM
AE410 5
9.05
9.05
9.05
C L
4" MIN.
23.01
CL
2' - 6"
22.12
23.03
22.15
C L C L
5.08
6.09
5.08
AE404
AE404
AE404
SIM.
SIM.
SIM.
1.04
1.05
1.06
F2000
A5075
A5082
22.16
22.06
AE501
7 SIM.
22.15
9.62
FE-A
CL
TOILET
TOILET
DRESSING ROOM
CL
T1
A5109
A5109
P1
AE410
AE410
AE410
1' - 6"
SIM
P1
P1 P2
P2
P5
P2
6.02
004 004
A5200
A5090
A5090
A5200
8' - 8 1/4" ±4' - 6"
6.14
6.14
6.14
ALIGN
ALIGN
JANITOR
S1 P1
3' - 6" ±
3' - 7 1/4" ±
22.08
P1
6.28
6.30
6.30
6.29
6.29
(4
T R
E A
D S
A T
(2
W
IN
D E
R S
/2
1' - 0"
3' - 11"
6.31
3' - 10 1/4"
AE403
AE403
AE403
AE311
AE311
/4
AE311
SIM.
6.14
(2) WINDERS
3' - 11"
1.05
1.03
1.05
1.03
A5075
A5075
A5082
A5082
F2000
F2000
22.16
22.16
22.11
1' - 8"
1.06
1.04
1.04
1.06
1.03
22.06
22.06
9.35
F4
F4
P2 1" ±
13' - 7" ±
9.05
9.05
9.05
ALIGN
F1
FE-B
125 SF
WOMEN'S
30 SF
TOILET
111A
A4995
111A
P2
P2
T1
P2
P2
/4
/4
ALIGN FACE OF TRIM
ALIGN
C L
AE4101
F1
F2
AE404
2' - 6"
CL
22.13
AE411
MECHANICAL
111B
T1
CL
3' - 6"
1' - 0"
/2
14' - 0" ±
101D
5' - 0"
5.08 6.11
AE404
8.08
6.09
AE404
AE404
AE404
/2
1' - 3"
C L
5' - 0"
T1
3' - 10 1/2"
A5200
A5090A5200 A5109
22.11
9.14
AE410
T2
22.06
A5090
10.08
P1
9.05
9.05
9.05
6" ±
23.01
4" MIN.
C L
23.03
C L
5.08
AE501
1.05
1.04
1.06
A5075
F2000
A5082 22.16
9 3/4"
22.07
6' - 6" ±
22.15
1.02
22.07
22.15
9.62
FE-A
GENERAL NOTES
A. REFER TO GI003/GI004 FOR ACCESSIBLE INSTALLATION REQUIREMENTS.
B. PROVIDE ADEQUATE SUPPORT BACKING (ANCHORING HARDWARE AND BLOCKING) FOR ALL WALL MOUNTED ITEMS
INCLUDING ITEMS PROVIDED AND OR INSTALLED BY THE VA.
C. PROVIDE UNDER SINK PIPE DRAIN INSULATION AT EXPOSED PLUMBING.
D. PROVIDE 1/2" RADIUS ON ALL COUNTERTOP EDGES AND CORNERS.
E. WALL FINISHINGS INCLUDING TILE CONTINUE BEHIND EQUIPMENT/ ACCESSORIES SHOWN IN ELEVATION.
F. TOILET PARTITIONS TO BE POWDER COATED FINISH.
G. ALL DIMENSIONS ARE TAKEN TO FINISHED FACE OF WALLS AND FINISHED FACE OF EXISTING STRUCTURE.
H. THE EDGE OF ALL DOOR JAMBS AT STRIKE SIDE, UNLESS INDICATED OTHERWISE, ARE TO BE 18" MINIMUM FROM THE
FACE OF INTERSECTING WALLS.
I. REFER TO M/E/P SHEETS FOR ALL MECHANICAL, ELECTRICAL AND PLUMBING RELATED WORK.
J. REFER TO STRUCTURAL SHEETS FOR ALL STRUCTURAL RELATED WORK.
K. ALL WOOD BLOCKING TO BE PRESSURE TREATED AT EXTERIOR LOCATIONS.
L. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED.
M. PROVIDE CONTROL JOINTS IN GYPSUM BOARD PER INDUSTRY STANDARDS AND STANDARD PRACTICES FOR GYPSUM
BOARD INSTALLATION.
N. ALL GYPSUM BOARD WALLS SHALL RECEIVE A LEVEL 4 FINISH, UNLESS NOTES OTHERWISE.
O. ALL EXPOSED GYPSUM BOARD IN RESTROOMS AND MECHANICAL ROOMS TO BE MOISTURE RESISTANCE.
P. SEE ROOM FINISH SCHEDULE FOR ALL WALL FINISHES.
Q. PATCH, REPAIR, AND CLEAN ALL EXISTING WALL SURFACES AND FLOOR STRUCTURES - PREPARE SURFACE TO
RECEIVE NEW PAINT.
LEGEND
X1000 ACCESSORY TAG - SEE ACCESSORY SCHEDULE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:5
P M
AE401
ENLARGED PLANS
05/30/2025 SS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
RESPONSIBILITY DEFINITIONS:
CV = CONTRACTOR PROVIDE / VA INSTALL
CC = CONTRACTOR PROVIDE / CONTRACTOR INSTALL
VV = VA PROVIDE / VA INSTALL
VC = VA PROVIDE / CONTRACTOR INSTALL
1/2" = 1'-0"
ENLARGED PLAN AT MEN'S RESTROOM
1/2" = 1'-0"
ENLARGED PLAN AT STAGE LEVEL RESTROOMS AND DRESSING ROOM
1/2" = 1'-0"
ENLARGED PLAN AT WOMEN'S RESTROOM
ACCESSORY SCHEDULE
TYPE MARK NAME VV VC CV CC COUNT
001 24" x 36" FRAMED MIRROR X 7
002 36" x 42" FRAMED MIRROR X 2
003 36" x 54" FRAMED MIRROR X 1
004 COUNTER HEIGHT STOOL X 2
005 DISPENSER, PAPER TOWEL, RECESSED WITH TRASH BOX X 2
A4995 TABLE, DIAPER CHANGING, WALL MOUNTED X 2
A5075 DISPENSER, SOAP X 4
A5082 DISPENSER, PAPER TOWEL, SENSOR, HANDS FREE X 4
A5090 DISPOSAL, SANITARY NAPKIN, SS, SURFACE MOUNTED X 5
A5109 GRAB BAR, 1-1/4" DIA., SS, W/C ACCESSIBLE (1'-6", 2'-0" & 3'-0") X 4
A5200 DISPENSER, TOILET TISSUE, SS, 2-ROLL, SURFACE MNTD X 5
F2000 BASKET, WASTEPAPER X 4
DRAWING NOTES:
1.02 REQUIRED 30" X 48" CLEAR FLOOR SPACE AT WATER FOUNTAIN
1.03 REQUIRED 30" X 48" CLEAR FLOOR SPACE BEYOND ARC OF DOOR SWING
1.04 REQUIRED 30" X 48" CLEAR FLOOR SPACE AT SINK
1.05 REQUIRED 54" X 60" CLEAR FLOOR SPACE AT WATER CLOSET
1.06 REQUIRED 60" TURNING RADIUS CLEAR FLOOR SPACE
5.08 1 1/2" DIA. BRASS HANDRAIL AT 36" AFF. - RAIL STYLE AND MOUNTINGS TO MATCH EXISTING BRASS RAILING
6.02 SOLID SURFACE COUNTERTOP WITH SIDE AND BACKSPLASH.
6.09 WOOD STAIR - STAIR TREADS AND RISERS TO BE CARPETED WITH CPT-1 - SEE FINISH LEGEND
6.11 RAISED FLOOR PLATFORM
6.14 WOOD SILL. PAINT TO MATCH NEW WINDOWS
6.28 NEW WOOD RAILING AT 42" A.F.F. TO MATCH ORIGINAL. TOP RAIL TO RECEIVE ST-1. BALUSTERS TO BE PAINTED P-1 - SEE
FINISH LEGEND
6.29 NEW WOOD HANDRAIL AT 36" A.F.F. STAIN ST-1 - SEE FINISH LEGEND
6.30 NEWEL POST TO MATCH HISTORIC ORIGINAL. STAIN TOP CAP ST-1 TO MATCH TOP RAILING. PAINT THE REST OF THE
POST P-1
6.31 WOOD STAIRS WITH WINDERS - NEW STAIR TREAD PROFILE NOSING, RISER BOARD, AND ALL ASSOCIATED TRIM TO
MATCH EXISTING - SEE FINISH PLAN FOR FINISH INFORMATION
8.08 EXISTING EXTERIOR WOOD DOORS TO REMAIN.
9.05 EXISTING SURFACES TO RECEIVE NEW SKIM COAT FINISH TO MATCH NEW LEVEL 4 FINISH TYPE - PAINT P-1 - SEE FINISH
LEGEND
9.14 SOLID SURFACE COUNTERTOP WITH PLASTIC LAMINATE APRON
9.35 REFINISH EXISTING CASED OPENING - REMOVE EXISTING LEAD BASED PAINT AND REPAINT TO MATCH EXISTING COLOR
AND SHEEN
9.62 NEW 3/4" PLYWOOD SUBFLOOR IN ENTIRE MECHANICAL ROOM - SEE ROOM FINISH SCHEDULE FOR NEW EPOXY
FLOORING AT THIS ROOM
10.08 1" CEILING HUNG COMPACT GRADE LAMINATE TOILET PARTITIONS TOILET PARTITIONS - SECURE TO CEILING AND WALL
STRUCTURE, PROVIDE BLOCKING AS NEEDED - SEE FINISH LEGEND
22.05 WALL MOUNTED URINAL - SEE PLUMBING DRAWINGS
22.06 FLOOR MOUNTED ACCESSIBLE WATER CLOSET - SEE PLUMBING DRAWINGS
22.07 FLOOR MOUNTED WATER CLOSET - SEE PLUMBING DRAWINGS
22.08 FLOOR MOUNTED MOP SINK WITH WALL SPLASH PANELS ON TWO SIDES UP TO 42" - SEE PLUMBING DRAWINGS
22.11 SINK - INTEGRAL TO COUNTERTOP - FINISH TO MATCH SS-1 - SEE FINISH LEGEND AND PLUMBING DRAWINGS
22.12 WALL MOUNTED DRINKING FOUNTAIN AT EXISTING PLASTERED WALL. COORDINATE MOUNTING PLATE WITH EXISTING
WALL REVEALS - SEE PLUMBING AND ELECTRICAL DRAWINGS
22.13 ACCESSIBLE DRINKING FOUNTAIN - SEE PLUMBING DRAWINGS
22.15 FLOOR DRAIN - SEE PLUMBING DRAWINGS
22.16 WALL MOUNTED SINK - ALL EXPOSED PLUMBING BELOW SINK TO RECEIVE INSULATED WRAP AROUND PIPES AND
FITTINGS - SEE PLUMBING DRAWINGS
23.01 MECHANICAL LOUVER IN EXISTING OPENING - SEE MECHANICAL DRAWINGS
23.03 RECESSED RETURN GRILLE / ACCESS PANEL. COORDINATE NEW OPENING AND GRILLE WITH EXISTING WALL REVEALS.
REBUILD / REPAIR HEAD, JAMB, AND SILL TO MATCH EXISTING WALL. FINISH COLOR TO MATCH P-1 - SEE FINISH LEGEND
AND MECHANICAL DRAWINGS
F1
P2
<varies>
AE41011
6.14
6.14
6.14
P1
P1
004001
3' - 8" 9' - 6 1/4" ±
6.18
6.28 6.29
6.29
6.30
6.30
2.84
6.35
(5
T R
E A
D S
A T
(2
W
IN
D E
R S
(2) WINDERS
3' - 6"
(2) WINDERS
3' - 7"
(2
W
IN
D E
R S
/2
(3) TREADS AT 11"
2' - 9"
45°
4' - 6"
/2
AE403
AE403
AE403
6.31
S1
P2
P2
P2
P1
AE311
AE311
AE311
SIM.
22.17
6.02
226 SF
DRESSING ROOM
251 SF
CORRIDOR
F4
P1
3' - 6"
9.05
F4
6.14
P4
FE-B
TOILET
TOILET
DRESSING ROOM
1' - 8"
CL
CL
1' - 6"
A5200
A5090
004 004
A5090
A5200AE410
4' - 6" 8' - 8 1/4" ±
P2
P1
P4 P2
T1
P2 P1
P1
AE410
8 SIM
AE410
7 SIM
ALIGN
ALIGN
6.14
6.14
6.14
AE403
AE403
AE311
AE311
AE311
SIM.
A5082
F2000
A5075
A5082
A5075
F2000
22.16
22.16
22.17 6.02
22.07
22.07
001001 001
6.14
1" ±
F4
9.05
9.05
6.14
AE410
P1
P2
P1
DRESSING ROOM
STORAGE
9' - 6" ±
6.02
22.14
CL
EQ
6.14
6.14
6.02
004 004
/4
P2
P1
001 001001
AE403
AE403
AE311
22.11
9.35
9.43
AE501
2.92
6.62
1.191.19
13' - 6" ±
9.05
9.05
9.05
P5
FE-C
AE405
14.01
9.13 P1
P2
ALIGN
ALIGN
102B
9.39
26.09
27.055.01
9.33
9.25
BOOTH
101D
CORRIDOR
101C
STAGE
AE405
12.01
6.61
6.61
4.17
4.17
4.19
AE404
6.11
AE404
SIM.
6.11
TYP
5.09
TYP
5.09
10.02
10.02
6.11
C L O
F A
IS
LE
GENERAL NOTES
A. REFER TO GI003/GI004 FOR ACCESSIBLE INSTALLATION REQUIREMENTS.
B. PROVIDE ADEQUATE SUPPORT BACKING (ANCHORING HARDWARE AND BLOCKING) FOR ALL WALL MOUNTED ITEMS
INCLUDING ITEMS PROVIDED AND OR INSTALLED BY THE VA.
C. PROVIDE UNDER SINK PIPE DRAIN INSULATION AT EXPOSED PLUMBING.
D. PROVIDE 1/2" RADIUS ON ALL COUNTERTOP EDGES AND CORNERS.
E. WALL FINISHINGS INCLUDING TILE CONTINUE BEHIND EQUIPMENT/ ACCESSORIES SHOWN IN ELEVATION.
F. TOILET PARTITIONS TO BE POWDER COATED FINISH.
G. ALL DIMENSIONS ARE TAKEN TO FINISHED FACE OF WALLS AND FINISHED FACE OF EXISTING STRUCTURE.
H. THE EDGE OF ALL DOOR JAMBS AT STRIKE SIDE, UNLESS INDICATED OTHERWISE, ARE TO BE 18" MINIMUM FROM THE
FACE OF INTERSECTING WALLS.
I. REFER TO M/E/P SHEETS FOR ALL MECHANICAL, ELECTRICAL AND PLUMBING RELATED WORK.
J. REFER TO STRUCTURAL SHEETS FOR ALL STRUCTURAL RELATED WORK.
K. ALL WOOD BLOCKING TO BE PRESSURE TREATED AT EXTERIOR LOCATIONS.
L. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED.
M. PROVIDE CONTROL JOINTS IN GYPSUM BOARD PER INDUSTRY STANDARDS AND STANDARD PRACTICES FOR GYPSUM
BOARD INSTALLATION.
N. ALL GYPSUM BOARD WALLS SHALL RECEIVE A LEVEL 4 FINISH, UNLESS NOTES OTHERWISE.
O. ALL EXPOSED GYPSUM BOARD IN RESTROOMS AND MECHANICAL ROOMS TO BE MOISTURE RESISTANCE.
P. SEE ROOM FINISH SCHEDULE FOR ALL WALL FINISHES.
Q. PATCH, REPAIR, AND CLEAN ALL EXISTING WALL SURFACES AND FLOOR STRUCTURES - PREPARE SURFACE TO
RECEIVE NEW PAINT.LEGEND
X1000 ACCESSORY TAG - SEE ACCESSORY SCHEDULE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:1
P M
AE402
ENLARGED PLANS
05/30/2025 SS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
1/2" = 1'-0"
ENLARGED PLAN AT BACK LEVEL 2 DRESSING ROOMS
1/2" = 1'-0"
ENLARGED PLAN AT BACK LEVEL 2 RESTROOMS AND DRESSING ROOM
1/2" = 1'-0"
ENLARGED PLAN AT DRESSING ROOM AND STORAGE
1/2" = 1'-0"
ENLARGED PLAN AT WHEELCHAIR LIFT AND BOOTH
1/2" = 1'-0"
ENLARGED PLAN AT WHEELCHAIR SEATING
RESPONSIBILITY DEFINITIONS:
CV = CONTRACTOR PROVIDE / VA INSTALL
CC = CONTRACTOR PROVIDE / CONTRACTOR INSTALL
VV = VA PROVIDE / VA INSTALL
VC = VA PROVIDE / CONTRACTOR INSTALL
ACCESSORY SCHEDULE
TYPE MARK NAME VV VC CV CC COUNT
001 24" x 36" FRAMED MIRROR X 13
003 36" x 54" FRAMED MIRROR X 1
004 COUNTER HEIGHT STOOL X 9
A5075 DISPENSER, SOAP X 2
A5082 DISPENSER, PAPER TOWEL, SENSOR, HANDS FREE X 2
A5090 DISPOSAL, SANITARY NAPKIN, SS, SURFACE MOUNTED X 2
A5200 DISPENSER, TOILET TISSUE, SS, 2-ROLL, SURFACE MNTD X 2
F2000 BASKET, WASTEPAPER X 2
DRAWING NOTES:
1.19 LINE INDICATES WHERE THE CONCRETE FLOOR STRUCTURE MEETS THE WOOD JOIST FLOOR
2.84 EXISTING DOOR TO REMAIN - PERMANENTLY SEAL SHUT
2.92 EXISTING CONCRETE SLAB TO REMAIN
4.17 TOOTH -IN NEW BRICK TO MATCH EXISTING ADJACENT AT EXISTING WALL
4.19 BRICK WALL INFILL - REUSE SALVAGED BRICK AND MATCH EXISTING ADJACENT
5.01 REMOVE EXISTING BRASS RAILING, CLEAN AND POLISH BACK TO ORIGINAL FINISH - REINSTALL IN EXISTING LOCATION
5.09 6" X 6" BRASS ADA SPOT LOCATION INDICATOR PLATE - SECURE TO FLOOR - TOP OF PLATE TO BE FLUSH WITH NEW
CARPET
6.02 SOLID SURFACE COUNTERTOP WITH SIDE AND BACKSPLASH.
6.11 RAISED FLOOR PLATFORM
6.14 WOOD SILL. PAINT TO MATCH NEW WINDOWS
6.18 INFILL FLOOR TO MATCH EXISTING ADJACENT
6.28 NEW WOOD RAILING AT 42" A.F.F. TO MATCH ORIGINAL. TOP RAIL TO RECEIVE ST-1. BALUSTERS TO BE PAINTED P-1 - SEE
FINISH LEGEND
6.29 NEW WOOD HANDRAIL AT 36" A.F.F. STAIN ST-1 - SEE FINISH LEGEND
6.30 NEWEL POST TO MATCH HISTORIC ORIGINAL. STAIN TOP CAP ST-1 TO MATCH TOP RAILING. PAINT THE REST OF THE
POST P-1
6.31 WOOD STAIRS WITH WINDERS - NEW STAIR TREAD PROFILE NOSING, RISER BOARD, AND ALL ASSOCIATED TRIM TO
MATCH EXISTING - SEE FINISH PLAN FOR FINISH INFORMATION
6.35 INFILL EXISTING CASED OPENING - EXTERIOR HEADER AND CASING TO REMAIN
6.61 REINSTALL EXISTING TRIM AND NEW CASED OPENING TO MATCH EXISTING - INSTALL EXISTING BASE AND NEW BASE AS
NEEDED - ALL NEW BASE TO MATCH EXISTING STYLE, COLOR, AND FINISH.
6.62 WHERE HARDWOOD IS INSTALLED OVER CONCRETE AREA, FLOOR TO FLOAT OVER CONCRETE - GLUE T/G SECTIONS TO
EACH OTHER
9.05 EXISTING SURFACES TO RECEIVE NEW SKIM COAT FINISH TO MATCH NEW LEVEL 4 FINISH TYPE - PAINT P-1 - SEE FINISH
LEGEND
9.13 CURTAIN (CRT-1) AT OPENING - INSTALL PER MANUFACTURER DETAILS - SEE FINISH LEGEND
9.25 REFINISH EXISTING WOOD BEAD BOARD AND TOP CAP - PATCH / REPAIR AREAS OF DAMAGE AS NEEDED TO ACHIEVE
ORIGINAL DESIGN - STAIN TO MATCH EXISTING COLOR AND FINISH
9.33 REMOVE EXISTING FINISH FROM ALL STAINED WOOD. PATCH / REPAIR AREAS OF DAMAGE AS NEEDED TO ACHIEVE
ORIGINAL DESIGN - STAIN ST-1 - SEE FINISH LEGEND
9.35 REFINISH EXISTING CASED OPENING - REMOVE EXISTING LEAD BASED PAINT AND REPAINT TO MATCH EXISTING COLOR
AND SHEEN
9.39 MAIN STAGE CURTAIN. FABRIC TO BE CRT-1 - SEE FINISH LEGEND AND AV DRAWINGS
9.43 CURTAIN (CRT-2) AT OPENING - INSTALL PER MANUFACTURER DETAILS - SEE FINISH LEGEND
10.02 (2) 33" X 48" SPECIFIED AREA FOR WHEELCHAIRS - SEE AV AND ELECTRICAL DRAWINGS FOR ACCESSIBILITY POWER AND
ASSISTED HEARING DEVICES
12.01 REFURBISH EXISTING THEATER SEATING. REUPHOLSTER CHAIR BACKS AND SEAT CUSHIONS (FAB-1). STRIP AND CLEAN EXISTING PAINT AND REPAINT METAL COMPONENTS OF SEATING (TBD). STRIP AND CLEAN WOOD COMPONENTS OF SEATING PRIOR TO RE-STAINING AND RE-INSTALLATION(TBD). REINSTALL REFURBISHED SEATS BACK TO ORIGINAL LOCATION IN CORRECT SEQUENTIAL ORDER IF REMOVED AS PART OF NEW WORK. PROVIDE NEW FUNCTIONAL SEAT HARDWARE TO RESTORE TYPICAL OPERATION TO ALL SEATS. AISLE SEATS CONTAIN INTEGRAL FOOTLIGHTING.
COORDINATE WITH ELECTRICAL DRAWINGS FOR NEW WIRING AND FIXTURE TYPE. ASSUME 25% OF AISLE SEAT
INTERIOR LIGHT COVERS ARE MISSING AND WILL BE REPLACED.
14.01 WHEELCHAIR LIFT TO STAGE - SECURE TO NEW CONCRETE PAD - COORDINATE ACCESS CONTROLS WITH HARDWARE
SPECIFICATIONS AND ELECTRICAL/ TECH. DRAWINGS
22.07 FLOOR MOUNTED WATER CLOSET - SEE PLUMBING DRAWINGS
22.11 SINK - INTEGRAL TO COUNTERTOP - FINISH TO MATCH SS-1 - SEE FINISH LEGEND AND PLUMBING DRAWINGS
22.14 ACCESSIBLE DRINKING FOUNTAIN WITH BOTTLE FILLER - SEE PLUMBING DRAWINGS
22.16 WALL MOUNTED SINK - ALL EXPOSED PLUMBING BELOW SINK TO RECEIVE INSULATED WRAP AROUND PIPES AND
FITTINGS - SEE PLUMBING DRAWINGS
22.17 SINK - INTEGRAL TO COUNTERTOP - FINISH TO MATCH SS-1 - ALL EXPOSED PLUMBING BELOW SINK TO RECEIVE INSULATED WRAP AROUND PIPES AND FITTINGS - SEE FINISH LEGEND AND PLUMBING DRAWINGS
26.09 (2) WALL MOUNTED LIGHT FIXTURES TO MATCH EXISTING DEMOLISHED - SEE STAGE INTERIOR ELEVATIONS AND
ELECTRICAL DRAWINGS
27.05 LOUDSPEAKER - SEE AUDIO-VISUAL AND TECHNOLOGY DRAWINGS
02.1-BACK LEVEL 2
1728' - 4"
01.1-STAGE
1717' - 6"
02.3 BOH T.O. ROOF
1737' - 4"
AE403
AE403
JANITOR
6.28
6.30
6.29
6.31
22.08
AE501
11SIM. 26.12
02.1-BACK LEVEL 2
1728' - 4"
01.1-STAGE
1717' - 6"
02.3 BOH T.O. ROOF
1737' - 4"
AE403
CORRIDOR
6.30 6.28
6.29
6.29
AE501
6.29
6.30
6.31
22.08
6.13
6.13
6.13
02.1-BACK LEVEL 2
1728' - 4"
01.1-STAGE
1717' - 6"
02.3 BOH T.O. ROOF
1737' - 4"
AE403
JANITOR
CORRIDOR
DRESSING ROOM
D
6.29
6.31
22.08
6.13
6.13
E
6.14
6.14
AE311
E
00-BASEMENT
1707' - 6"
02.1-BACK LEVEL 2
1728' - 4"
01.1-STAGE
1717' - 6"
00.1-ORCHESTRA PIT
1711' - 11"
02.3 BOH T.O. ROOF
1737' - 4"
MECH/ELEC ROOM
TOILET
TOILET
CORRIDOR
SLOPE SLOPE
AE311
CORRIDOR
MECH/ELEC ROOM
STAGE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:2
P M
AE403
ENLARGED SECTIONS
05/30/2025 SS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
DRAWING NOTES:
6.13 2X BRIDGING BOARDS AT 12" O.C. AT WALLS THAT FALL PARALLEL BETWEEN JOISTS / RAFTERS -
6.14 WOOD SILL. PAINT TO MATCH NEW WINDOWS
6.28 NEW WOOD RAILING AT 42" A.F.F. TO MATCH ORIGINAL. TOP RAIL TO RECEIVE ST-1. BALUSTERS TO BE PAINTED P-1 - SEE
FINISH LEGEND
6.29 NEW WOOD HANDRAIL AT 36" A.F.F. STAIN ST-1 - SEE FINISH LEGEND
6.30 NEWEL POST TO MATCH HISTORIC ORIGINAL. STAIN TOP CAP ST-1 TO MATCH TOP RAILING. PAINT THE REST OF THE
POST P-1
6.31 WOOD STAIRS WITH WINDERS - NEW STAIR TREAD PROFILE NOSING, RISER BOARD, AND ALL ASSOCIATED TRIM TO
MATCH EXISTING - SEE FINISH PLAN FOR FINISH INFORMATION
22.08 FLOOR MOUNTED MOP SINK WITH WALL SPLASH PANELS ON TWO SIDES UP TO 42" - SEE PLUMBING DRAWINGS
26.12 EXTERIOR LIGHT FIXTURE - INSTALL IN SAME LOCATION AS DEMOLISHED FIXTURE - SEE ELECTRICAL DRAWINGS
1/4" = 1'-0"
SECTION AT NEW STAIR
1/4" = 1'-0"
SECTION AT NEW STAIR
1/4" = 1'-0"
SECTION AT NEW STAIR
1/4" = 1'-0"
BUILDING SECTION AT BACK OF HOUSE
01.2-FIRST FLOOR
1718' - 6"
5.08
1' - 0"
(3
R
IS
E R
S A
T
/2
V
.I .F
H A
N D
R A
IL
5' - 0"
8.08
6.11
6.09
AE404
(2) TREADS AT 11"
1' - 10"
" 01.2-FIRST FLOOR
1718' - 6"
AE404
8.08
5.08
2.55
6.27
6.23
7.11
6.24
6.25
6.20
01.2-FIRST FLOOR
1718' - 6"
AE404
4" ±
5.08
2.55
2.57
2.56
6.24
6.25
6.27
6.23
7.11
6.26
2.57
2.56
AE501
6.20
6.27
10.08
01.2-FIRST FLOOR
1718' - 6"
AE404
V .I
.F
/2
5.08
26.05
2.55
TYP
12.02
6.206.23 7.116.256.24
AE501
SIM.
6.27
2.57
2.56
01.2-FIRST FLOOR
1718' - 6"
AE404
5.08
TYP
12.02
6.27
6.23
01.2-FIRST FLOOR
1718' - 6"
6.19
TYP
12.02
1' - 3"
9.38
2.55
5.21
6.38
AE501
01.1-STAGE
1717' - 6"
00.1-ORCHESTRA PIT
1711' - 11"
(4
E Q
R
IS
E R
S A
T
/4
9.36
5.08
(3) TREADS AT 11"
2' - 9"
C L
E A
R
C L
E Q
E Q
O F
S T
A G
E
5.08
6.22
5.08
9.36
AE404
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:2
P M
AE404
ENLARGED PLANS AND SECTION
DETAILS
05/30/2025 SS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
1/2" = 1'-0"
SECTION AT NEW STAIR
1/2" = 1'-0"
SECTION DETAIL AT NEW PLATFORM AND EXISTING DOOR
1/2" = 1'-0"
SECTION DETAIL AT NEW RESTROOM FLOOR PLATFORM
1/2" = 1'-0"
SECTION DETAIL AT NEW PLATFORM
1/2" = 1'-0"
SECTION DETAIL AT NEW PLATFORM
DRAWING NOTES:
2.55 EXISTING FLOOR JOIST STRUCTURE AND FLOORING TO REMAIN
2.56 EXISTING FLOOR BEAM TO REMAIN
2.57 EXISTING FLOOR FOUNDATION TO REMAIN
5.08 1 1/2" DIA. BRASS HANDRAIL AT 36" AFF. - RAIL STYLE AND MOUNTINGS TO MATCH EXISTING BRASS RAILING
5.21 6" X 6" BRASS ADA SPOT LOCATION INDICATOR PLATE - SECURE TO FLOOR
6.09 WOOD STAIR - STAIR TREADS AND RISERS TO BE CARPETED WITH CPT-1 - SEE FINISH LEGEND
6.11 RAISED FLOOR PLATFORM
6.19 2X LEDGER BOARD
6.20 2X6 LEDGER BOARD
6.22 WOOD STAIR FROM ORCHESTRA PIT TO AUDITORIUM FLOOR. CENTER ON STAGE - STAIN ST-2 TO MATCH REFINISHED
HARDWOOD FLOORING - SEE FINISH PLAN AND LEGEND
6.23 2X6 JOISTS AT 12" O.C.
6.24 3/4" PLYWOOD SUBFLOOR, ALIGN FLUSH TO EXISTING SUBFLOOR
6.25 T/G HARDWOOD FLOORING - ALIGN TO EXISTING PATTERN AND RUN
6.26 BASEBOARD - STYLE, PROFILE, AND FINISH TO MATCH EXISTING
6.27 2X4 STUD WALL AT 16" O.C.
6.38 OAK WOOD FLOOR STOP RAILING WITH INTEGRAL LED LIGHTING - SEE DETAIL 4/AE501
7.11 5 1/2" CLOSED CELL SPRAY FOAM INSULATION WITH INTEGRATED INTUMESCENT PROTECTION.
8.08 EXISTING EXTERIOR WOOD DOORS TO REMAIN.
9.36 VELCRO AT EDGE OF CURTAIN (CRT-1) FOR OPENING TO NEW ORCHESTRA PIT STAIR - SEE FINISH LEGEND
9.38 CARPET (CPT-1) - SEE FINISH PLANS AND LEGEND
10.08 1" CEILING HUNG COMPACT GRADE LAMINATE TOILET PARTITIONS TOILET PARTITIONS - SECURE TO CEILING AND WALL
STRUCTURE, PROVIDE BLOCKING AS NEEDED - SEE FINISH LEGEND
12.02 AUDITORIUM CHAIRS - SEE NEW WORK PLANS
26.05 NEW CUSTOM CEILING HUNG CHANDELIER - INSTALL IN SAME LOCATION AS DEMOLISHED FIXTURE - SEE ELECTRICAL
DRAWINGS
1/2" = 1'-0"
SECTION DETAIL AT NEW WHEELCHAIR AREA
1/2" = 1'-0"
SECTION AT ORCHESTRA PIT STAIR
1/2" = 1'-0"
ENLARGED PLAN AT ORCHESTRA PIT STAIR
00-BASEMENT
1707' - 6"
01.1-STAGE
1717' - 6"
00.1-ORCHESTRA PIT
1711' - 11"
6' - 11" ±3' - 0" CLR9" ±
14.01
8.09
3.124
EXIST.
5.16
AE405
G R
A D
E V
A R
IE
S
7.63
6.61
00-BASEMENT
1707' - 6"
01.1-STAGE
1717' - 6"
AE405
14.01
2.51
7.09
7.07
7.08
G R
A D
E V
A R
IE
S
7.63
5.29
5.30
6.67
9.47
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:3
P M
AE405
ENLARGED SECTION DETAILS
05/30/2025 SS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
1/2" = 1'-0"
SECTION AT NEW WHEELCHAIR LIFT
1/2" = 1'-0"
SECTION AT NEW WHEELCHAIR LIFT
DRAWING NOTES:
2.51 EXISTING FOUNDATION WALL
3.12 CONCRETE SILL AT NEW OPENING - SECURE TO EXISTING BRICK - TOP TO BE FLUSH WITH EXISTING WOOD STAGE
FLOOR
5.16 STEEL LINTEL ABOVE NEW OPENING AT EXISTING BRICK WALL - SEE STRUCTURAL DRAWINGS
5.29 NEW STEEL LIFT SUPPORT BRACKET SECURED TO EXISTING WALL STRUCTURE - REMOVE PORTION OF FLOOR AT
BRACKET ONLY - TOP PLATE OF BRACKET TO BE LEVEL TO FINISHED FLOOR - SEE STRUCTURAL DRAWINGS AND
COORDINATE WITH LIFT MANUFACTURE ON FASTENING
5.30 SECURE LIFT MOTOR TO WALL STRUCTURE - SEE STRUCTURAL DRAWINGS AND COORDINATE WITH LIFT MANUFACTURE
ON FASTENING
6.61 REINSTALL EXISTING TRIM AND NEW CASED OPENING TO MATCH EXISTING - INSTALL EXISTING BASE AND NEW BASE AS
NEEDED - ALL NEW BASE TO MATCH EXISTING STYLE, COLOR, AND FINISH.
6.67 INSTALL NEW FLOOR JOIST FRAMING AROUND NEW STEEL SUPPORT BRACKET - SECURE TO EXITING FLOOR JOIST
FRAMING
7.07 FLUID APPLIED MOISTURE BARRIER WITH DRAIN BOARD AT EXISTING FOUNDATION WALLS - EXTEND FROM TOP OF
GRADE DOWN TO EXISTING TOP OF FOOTING
7.08 6" SLOTTED SOLID WALL DRAIN TILE WITH FABRIC SLEEVE - SEE CIVIL DRAWINGS
7.09 WASHED GRAVEL AT NEW DRAIN BOARD
7.63 CONTINUOUS 15MILL VAPOR BARRIER OVER EXISTING EXPOSED GRADE AT ENTIRE CRAWL SPACE - TURN UP ALL WALLS
TO 3"MIN BELOW FLOOR JOISTS - TURN UP AND WRAP ALL CONCRETE PIERS
8.09 ARCHED OPENING TO BOOTH
9.47 TOOTH IN NEW HARDWOOD FLOORING WITH EXISTING - MATCH EXISTING SIZE AND SPECIES.
14.01 WHEELCHAIR LIFT TO STAGE - SECURE TO NEW CONCRETE PAD - COORDINATE ACCESS CONTROLS WITH HARDWARE
SPECIFICATIONS AND ELECTRICAL/ TECH. DRAWINGS
PT-1
F2000
A5082
A5075
22.16
26.07
A4995
P-1
CTB-1
22.07
A5109
PT-1
A5200
A5090
A5082
A5075
F2000
22.16
26.07
22.06 6.02
004 004
001 001 001
SS-1
P-1
P-1
WB-1
TYP
5.05
22.17
TYP
26.02
A5200
A5090
PT-1
A5082
A5075
F2000
26.07
22.16
22.07
001 001 001
004004004
SS-1
P-1
WB-1
001 001
6.02
TYP
26.02
22.17
TYP
5.05
002005
22.11
9.14
SS-1
PL-1
P-1 PT-1
10.08
CTB-1
/2
26.08
PT-1
A5109
A5090
A5200
10.08
22.07
8.04
22.06
PT-1
22.05A5109
A5200 A5090
10.08
22.06
8.04
LEGEND
X1000
X-X
ACCESSORY TAG - SEE ACCESSORY SCHEDULE
MATERIAL TAG - SEE INTERIOR FINISH SCHEDULE
GENERAL NOTES
A. REFER TO GI003/GI004 FOR ACCESSIBLE INSTALLATION REQUIREMENTS.
B. PROVIDE ADEQUATE SUPPORT BACKING (ANCHORING HARDWARE AND BLOCKING) FOR ALL WALL MOUNTED ITEMS
INCLUDING ITEMS PROVIDED AND OR INSTALLED BY THE VA.
C. PROVIDE UNDER SINK PIPE DRAIN INSULATION AT EXPOSED PLUMBING.
D. PROVIDE 1/2" RADIUS ON ALL COUNTERTOP EDGES AND CORNERS.
E. WALL FINISHINGS INCLUDING TILE CONTINUE BEHIND EQUIPMENT/ ACCESSORIES SHOWN IN ELEVATION.
F. TOILET PARTITIONS TO BE POWDER COATED FINISH.
G. ALL DIMENSIONS ARE TAKEN TO FINISHED FACE OF WALLS AND FINISHED FACE OF EXISTING STRUCTURE.
H. THE EDGE OF ALL DOOR JAMBS AT STRIKE SIDE, UNLESS INDICATED OTHERWISE, ARE TO BE 18" MINIMUM FROM THE
FACE OF INTERSECTING WALLS.
I. REFER TO M/E/P SHEETS FOR ALL MECHANICAL, ELECTRICAL AND PLUMBING RELATED WORK.
J. REFER TO STRUCTURAL SHEETS FOR ALL STRUCTURAL RELATED WORK.
K. ALL WOOD BLOCKING TO BE PRESSURE TREATED AT EXTERIOR LOCATIONS.
L. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED.
M. PROVIDE CONTROL JOINTS IN GYPSUM BOARD PER INDUSTRY STANDARDS AND STANDARD PRACTICES FOR GYPSUM
BOARD INSTALLATION.
N. ALL GYPSUM BOARD WALLS SHALL RECEIVE A LEVEL 4 FINISH, UNLESS NOTES OTHERWISE.
O. ALL EXPOSED GYPSUM BOARD IN RESTROOMS AND MECHANICAL ROOMS TO BE MOISTURE RESISTANCE.
P. SEE ROOM FINISH SCHEDULE FOR ALL WALL FINISHES.
Q. PATCH, REPAIR, AND CLEAN ALL EXISTING WALL SURFACES AND FLOOR STRUCTURES - PREPARE SURFACE TO
RECEIVE NEW PAINT.
001 001 001
SS-1
WB-1
004 004 004
6.10
TYP
5.05
TYP
26.02
P-1
1" FILLER3' - 0"1' - 9"
PL-1
SS-1
P-1
22.11
6.02
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:4
P M
AE410
INTERIOR ELEVATIONS
05/30/2025 SPS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
RESPONSIBILITY DEFINITIONS:
CV = CONTRACTOR PROVIDE / VA INSTALL
CC = CONTRACTOR PROVIDE / CONTRACTOR INSTALL
VV = VA PROVIDE / VA INSTALL
VC = VA PROVIDE / CONTRACTOR INSTALL
1/2" = 1'-0"
INTERIOR ELEVATION AT RESTROOM
1/2" = 1'-0"
INTERIOR ELEVATION AT RESTROOM
1/2" = 1'-0"
INTERIOR ELEVATION AT ACCESSIBLE UNISEX RESTROOM
1/2" = 1'-0"
INTERIOR ELEVATION AT DRESSING ROOMS
1/2" = 1'-0"
INTERIOR ELEVATION AT UNISEX RESTROOM
1/2" = 1'-0"
INTERIOR ELEVATION AT DRESSING ROOM 207
1/2" = 1'-0"
INTERIOR ELEVATION AT RESTROOMS
1/2" = 1'-0"
INTERIOR ELEVATION AT WOMEN'S RESTROOM
1/2" = 1'-0"
INTERIOR ELEVATION AT MEN'S RESTROOM
ACCESSORY SCHEDULE - TOTALS
TYPE MARK NAME VV VC CV CC COUNT
001 24" x 36" FRAMED MIRROR X 20
002 36" x 42" FRAMED MIRROR X 2
003 36" x 54" FRAMED MIRROR X 1
004 COUNTER HEIGHT STOOL X 11
005 DISPENSER, PAPER TOWEL, RECESSED WITH TRASH BOX X 2
A4995 TABLE, DIAPER CHANGING, WALL MOUNTED X 2
A5075 DISPENSER, SOAP X 6
A5082 DISPENSER, PAPER TOWEL, SENSOR, HANDS FREE X 6
A5090 DISPOSAL, SANITARY NAPKIN, SS, SURFACE MOUNTED X 7
A5109 GRAB BAR, 1-1/4" DIA., SS, W/C ACCESSIBLE (1'-6", 2'-0" & 3'-0") X 4
A5200 DISPENSER, TOILET TISSUE, SS, 2-ROLL, SURFACE MNTD X 7
F2000 BASKET, WASTEPAPER X 6
DRAWING NOTES:
5.05 CONCEALED MOUNTING BRACKET AT 16" O.C. STARTING IN CENTER OF COUNTERTOP RUN
6.02 SOLID SURFACE COUNTERTOP WITH SIDE AND BACKSPLASH.
6.10 SOLID SURFACE COUNTERTOP WITH BACKSPLASH
8.04 12 X 12 ACCESS PANEL WITH LOCK - PAINT TO MATCH WALL TILE COLOR - SEE PLUMBING DRAWINGS FOR LOCATION
COORDINATION.
9.14 SOLID SURFACE COUNTERTOP WITH PLASTIC LAMINATE APRON
10.08 1" CEILING HUNG COMPACT GRADE LAMINATE TOILET PARTITIONS TOILET PARTITIONS - SECURE TO CEILING AND WALL
STRUCTURE, PROVIDE BLOCKING AS NEEDED - SEE FINISH LEGEND
22.05 WALL MOUNTED URINAL - SEE PLUMBING DRAWINGS
22.06 FLOOR MOUNTED ACCESSIBLE WATER CLOSET - SEE PLUMBING DRAWINGS
22.07 FLOOR MOUNTED WATER CLOSET - SEE PLUMBING DRAWINGS
22.11 SINK - INTEGRAL TO COUNTERTOP - FINISH TO MATCH SS-1 - SEE FINISH LEGEND AND PLUMBING DRAWINGS
22.16 WALL MOUNTED SINK - ALL EXPOSED PLUMBING BELOW SINK TO RECEIVE INSULATED WRAP AROUND PIPES AND
FITTINGS - SEE PLUMBING DRAWINGS
22.17 SINK - INTEGRAL TO COUNTERTOP - FINISH TO MATCH SS-1 - ALL EXPOSED PLUMBING BELOW SINK TO RECEIVE INSULATED WRAP AROUND PIPES AND FITTINGS - SEE FINISH LEGEND AND PLUMBING DRAWINGS
26.02 SURFACE MOUNTED 6" DIAMETER SCONCE - SEE ELECTRICAL DRAWINGS
26.07 WALL MOUNTED 3 BULB LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
26.08 WALL MOUNTED 5 BULB LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
1/2" = 1'-0"
INTERIOR ELEVATION AT DRESSING ROOM 108
1/2" = 1'-0"
INTERIOR ELEVATION AT DRESSING ROOM 108
6.03
6.04
9.01
6.05
6.089.02
TYP
6.08
9.06
P29 P29
P28
P29
P26
TYP
6.06 P29
P27 P27
M A
X
22.13 23.03
23.04
6.03
TYP
6.08
6.05
6.04
6.08 9.02
9.01
9.06
P29 P29
P28
P29
P26
P27 P27
TYP
6.05P29
8.10
22.1223.03
23.04
9.03 P25
A
9.01
9.03
6.04
P30
P28
6.15
A
9.01
6.04P28
P30
6.15
AE411
AE411
LOBBY
LOBBY
LOBBY
MECH/ELEC
AE422
__________ 1
AE423
PROJECTOR BOOTH
100D 100E 100F
TYP
6.06
TYP
6.06
9.32 9.32
TYP
6.08
TYP
6.08
9.019.01
TYP
9.01
9.28
9.06
9.119.11
9.06
P31 P31
928P28
P26
P27
P29P29
P28
P31 P31
P27
P30 P30
TYP
6.15
AE501
9.27 P28
9.28 P28
9.27P28
ATTIC
GG
2.61 2.61
MECHANICAL
111B
MECHANICAL
110B
C7
C8C8
C7 C7
LEGEND
X EXISTING CONDITION PHOTO NUMBER - SEE SHEETS AE700, AE701 & AE702
X
WINDOW TYPE - SEE SHEET AE603 - TYPICAL WINDOW ELEVATIONS FOR RESTORATION SCOPE
DOOR NUMBER - SEE SHEET AE602 - TYPICAL DOOR ELEVATIONS FOR RESTORATION SCOPE
CX CURTAIN TYPE - SEE SHEET AE605 - TYPICAL CURTAIN ELEVATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:0
P M
AE411
INTERIOR SECTIONS &
ELEVATIONS - LOBBY
05/30/2025 SPS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
DRAWING NOTES:
2.61 EXISTING WALL MOUNT LIGHT FIXTURE TO REMAIN. CLEAN AND REPAIR - ALL FIXTURES TO BE RELAMPED - SEE
ELECTRICAL DRAWINGS
6.03 REINSTALL TRIM TO MATCH EXISTING
6.04 CLEAN AND REFINISH WOOD HANDRAILS. STAIN ST-1 - SEE FINISH LEGEND
6.05 REFINISH WOOD NEWEL POST. STAIN ST-1 SEE FINISH LEGEND
6.06 PAINT EXISTING WOOD BALUSTERS P-1 - SEE FINISH LEGEND
6.08 PAINT EXISTING WOOD TRIM P-1 - SEE FINISH LEGEND
6.15 CLEAN AND POLISH EXISTING WOOD TRIM
8.10 18" X 24" INSULATED ACCESS PANEL DOOR WITH LOCKING HANDLE. FACE OF PANEL TO MATCH EXISTING WALL - PAINT
P-1
9.01 REMOVE ALL EXISTING CHIPPED, BLISTERED, ETC. DAMAGED WALL SURFACE. ALL EXISTING SURFACES TO RECEIVE
NEW SKIM COAT FINISH. PAINT P-1 - SEE FINISH LEGEND
9.02 CLEAN EXISTING MARBLE TRIM
9.03 REPAIR PLASTER WALL. PAINT P-1 - SEE FINISH LEGEND
9.06 REPLACE CARPET AND REFINISH WOOD STAIRS. CARPET TO BE CPT-1. STAIN WOOD ST-1 - SEE FINISH PLANS AND
LEGEND
9.11 REPLACE CARPET AT STAIRS. CARPET TO BE CPT-1 - SEE FINISH PLANS AND LEGEND
9.27 REFINISH EXISTING WOOD HANDRAIL - REMOVE EXISTING STAIN FINISH AND PATCH / REPAIR ANY PORTIONS AS NEEDED
TO REPAIR BACK TO ORIGINAL - STAIN ST-1 - SEE FINISH LEGEND
9.28 REFINISH EXISTING WOOD RAILING - REMOVE EXISTING STAIN AND PAINT FINISH AND PATCH / REPAIR ANY PORTIONS AS
NEEDED TO REPAIR BACK TO ORIGINAL - TOP RAIL TO RECEIVE ST-1 AND BALUSTERS TO RECEIVE P-1 - SEE FINISH
LEGEND
9.32 REFINISH EXISTING WOOD HANDRAIL AND BALUSTERS - REMOVE EXISTING STAIN FINISH AND PATCH / REPAIR ANY
PORTIONS AS NEEDED TO REPAIR BACK TO ORIGINAL - STAIN ST-1 - SEE FINISH LEGEND
22.12 WALL MOUNTED DRINKING FOUNTAIN AT EXISTING PLASTERED WALL. COORDINATE MOUNTING PLATE WITH EXISTING
WALL REVEALS - SEE PLUMBING AND ELECTRICAL DRAWINGS
22.13 ACCESSIBLE DRINKING FOUNTAIN - SEE PLUMBING DRAWINGS
23.03 RECESSED RETURN GRILLE / ACCESS PANEL. COORDINATE NEW OPENING AND GRILLE WITH EXISTING WALL REVEALS.
REBUILD / REPAIR HEAD, JAMB, AND SILL TO MATCH EXISTING WALL. FINISH COLOR TO MATCH P-1 - SEE FINISH LEGEND
AND MECHANICAL DRAWINGS
23.04 SUPPLY GRILLE - SEE MECHANICAL DRAWINGS
1/4" = 1'-0"
INTERIOR ELEVATION AT GRAND STAIR
1/4" = 1'-0"
INTERIOR ELEVATION AT GRAND STAIR 1/4" = 1'-0"
SECTION AT GRAND STAIR
1/4" = 1'-0"
SECTION AT GRAND STAIR
1/4" = 1'-0"
SECTION AT LOBBY
QUANTIFIED KEYNOTES - TOTALS
# KEYNOTE
≈ LINEAR
FEET
≈ SQUARE
FEET
TOTAL
LOCATIONS
9.03 REPAIR PLASTER WALL. PAINT P-1 0 18 0
NOTE: GREYED OUT CELLS REPRESENT INVALID METHOD OF QUANTIFICATION PER KEYNOTE.
AE411
AE411
LOBBY
LOBBY
LOBBY
MECH/ELEC
PROJECTOR BOOTH
100C 100B 100A
200A200C
9.06
TYP
6.08
6.04
6.04
6.05
TYP
6.06
6.04
6.04
6.05
TYP
6.06
9.06
TYP
6.08
TYP
9.02
P26
P28
P29
P29
P27P29 P27 P29
P29
P29
P28
ATTIC
2.612.61
MECHANICAL
111B
MECHANICAL
110B
26.0526.05 26.05
LOBBY
200B200C 200A 6.04
6.06
6.04
6.06
9.01 9.01
P28
P28
P28
P28
P30 P30
TYP
6.15
TYP
2.61
9.63
C1
LEGEND
X EXISTING CONDITION PHOTO NUMBER - SEE SHEETS AE700, AE701 & AE702
X
WINDOW TYPE - SEE SHEET AE603 - TYPICAL WINDOW ELEVATIONS FOR RESTORATION SCOPE
DOOR NUMBER - SEE SHEET AE602 - TYPICAL DOOR ELEVATIONS FOR RESTORATION SCOPE
CX CURTAIN TYPE - SEE SHEET AE605 - TYPICAL CURTAIN ELEVATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:1
P M
AE412
INTERIOR SECTIONS & ELEVATIONS
- LOBBY & BASEMENT
05/30/2025 SPS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
DRAWING NOTES:
2.61 EXISTING WALL MOUNT LIGHT FIXTURE TO REMAIN. CLEAN AND REPAIR - ALL FIXTURES TO BE RELAMPED - SEE
ELECTRICAL DRAWINGS
6.04 CLEAN AND REFINISH WOOD HANDRAILS. STAIN ST-1 - SEE FINISH LEGEND
6.05 REFINISH WOOD NEWEL POST. STAIN ST-1 SEE FINISH LEGEND
6.06 PAINT EXISTING WOOD BALUSTERS P-1 - SEE FINISH LEGEND
6.08 PAINT EXISTING WOOD TRIM P-1 - SEE FINISH LEGEND
6.15 CLEAN AND POLISH EXISTING WOOD TRIM
9.01 REMOVE ALL EXISTING CHIPPED, BLISTERED, ETC. DAMAGED WALL SURFACE. ALL EXISTING SURFACES TO RECEIVE
NEW SKIM COAT FINISH. PAINT P-1 - SEE FINISH LEGEND
9.02 CLEAN EXISTING MARBLE TRIM
9.06 REPLACE CARPET AND REFINISH WOOD STAIRS. CARPET TO BE CPT-1. STAIN WOOD ST-1 - SEE FINISH PLANS AND
LEGEND
9.63 PARTITION INFILL AT EXISTING MASONRY OPENING - ORCHESTRA FINISHED SIDE TO RECEIVE T/G WOOD WALL BOARD TO
MATCH EXISTING - PROVIDE SOUND BATTS IN WALL CAVITY AND SEAL ALL EDGES.
26.05 NEW CUSTOM CEILING HUNG CHANDELIER - INSTALL IN SAME LOCATION AS DEMOLISHED FIXTURE - SEE ELECTRICAL
DRAWINGS
1/4" = 1'-0"
SECTION AT LOBBY
1/4" = 1'-0"
INTERIOR ELEVATION AT LOBBY
1/4" = 1'-0"
INTERIOR ELEVATION - BASEMENT
QUANTIFIED KEYNOTES - TOTALS
# KEYNOTE
≈ LINEAR
FEET
≈ SQUARE
FEET
TOTAL
LOCATIONS
01.1-STAGE
1717' - 6"
04.2-ATTIC
1756' - 0"
B B B
5.10
5.12
5.11
5.19
5.18
5.07
TYP
27.01
TYP
27.02
5.10
5.24
5.11
5.12
TYP
9.41
TYP
9.41
01.1-STAGE
1717' - 6"
04.2-ATTIC
1756' - 0"
5.16
5.11
5.12
TYP
27.01
102B 102A
TYP
9.41
TYP
9.41
26.13 26.13
4.17
4' - 0" ± 6' - 4" ±
4.19
5' - 4"
LEGEND
X EXISTING CONDITION PHOTO NUMBER - SEE SHEETS AE700, AE701 & AE702
X
WINDOW TYPE - SEE SHEET AE603 - TYPICAL WINDOW ELEVATIONS FOR RESTORATION SCOPE
DOOR NUMBER - SEE SHEET AE602 - TYPICAL DOOR ELEVATIONS FOR RESTORATION SCOPE
CX CURTAIN TYPE - SEE SHEET AE605 - TYPICAL CURTAIN ELEVATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:3
P M
AE413
INTERIOR ELEVATIONS - STAGE
05/30/2025 SPS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
DRAWING NOTES:
4.17 TOOTH -IN NEW BRICK TO MATCH EXISTING ADJACENT AT EXISTING WALL
4.19 BRICK WALL INFILL - REUSE SALVAGED BRICK AND MATCH EXISTING ADJACENT
5.07 METAL FRAMING FOR RIGGING - SEE STRUCTURAL DRAWINGS
5.10 PRE-ENGINEERED STEEL SHIPS LADDER. PAINT P-3. SECURE TO EXISTING AND NEW STRUCTURE - SEE FINISH LEGEND
AND STRUCTURAL DRAWINGS
5.11 METAL CATWALK - PAINT P-3 - SEE FINISH LEGEND
5.12 PRE ENGINEERED METAL GUARD RAIL AT 42" AFF. PAINT P-3 - SEE FINISH LEGEND
5.16 STEEL LINTEL ABOVE NEW OPENING AT EXISTING BRICK WALL - SEE STRUCTURAL DRAWINGS
5.18 PRE ENGINEERED METAL GRATE STAIR WITH INTEGRATED GUARD AND HANDRAIL. PAINT P-3 - SEE FINISH LEGEND AND
STRUCTURAL DRAWINGS
5.19 1 1/2" DIA. STEEL GUARD AT 42" AFF. WITH 1 1/2" DIA. STAINLESS STEEL HANDRAIL AT 36" AFF. - RAILING TO BE WELDED
TO TOP OF STEEL STAIR STRINGER. PAINT P-3 - SEE FINISH LEGEND
5.24 WALL LADDER - SECURE TO EXISTING STRUCTURE
9.41 PAINT MECHANICAL DUCTWORK P-3. TYPICAL ALL DUCTWORK AT STAGE - SEE FINISH LEGEND
26.13 WALL MOUNTED LIGHT FIXTURE TO MATCH EXISTING DEMOLISHED. INSTALL IN SAME LOCATION AS DEMOLISHED
FIXTURE - SEE ELECTRICAL DRAWINGS
27.01 RIGGING - SEE TECHNOLOGY DRAWINGS
27.02 LOFT BLOCKS - SEE TECHNOLOGY DRAWINGS
1/4" = 1'-0"
INTERIOR ELEVATION AT STAGE
1/4" = 1'-0"
INTERIOR ELEVATION AT STAGE
QUANTIFIED KEYNOTES - TOTALS
# KEYNOTE
≈ LINEAR
FEET
≈ SQUARE
FEET
TOTAL
LOCATIONS
01.1-STAGE
1717' - 6"
04.2-ATTIC
1756' - 0"
TYP
5.18
TYP
5.19
5.07
27.0227.02
TYP
27.01
2.84
5.23
5.24
5.12
5.10
/2
5.07
TYP
9.41
TYP
9.41
01.1-STAGE
1717' - 6"
04.2-ATTIC
1756' - 0"
102C
B B B
TYP
27.01
5.07
TYP
27.02
5.23
TYP
9.41
TYP
9.41
LEGEND
X EXISTING CONDITION PHOTO NUMBER - SEE SHEETS AE700, AE701 & AE702
X
WINDOW TYPE - SEE SHEET AE603 - TYPICAL WINDOW ELEVATIONS FOR RESTORATION SCOPE
DOOR NUMBER - SEE SHEET AE602 - TYPICAL DOOR ELEVATIONS FOR RESTORATION SCOPE
CX CURTAIN TYPE - SEE SHEET AE605 - TYPICAL CURTAIN ELEVATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:4
P M
AE414
INTERIOR ELEVATIONS - STAGE
05/30/2025 SPS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
DRAWING NOTES:
2.84 EXISTING DOOR TO REMAIN - PERMANENTLY SEAL SHUT
5.07 METAL FRAMING FOR RIGGING - SEE STRUCTURAL DRAWINGS
5.10 PRE-ENGINEERED STEEL SHIPS LADDER. PAINT P-3. SECURE TO EXISTING AND NEW STRUCTURE - SEE FINISH LEGEND
AND STRUCTURAL DRAWINGS
5.12 PRE ENGINEERED METAL GUARD RAIL AT 42" AFF. PAINT P-3 - SEE FINISH LEGEND
5.18 PRE ENGINEERED METAL GRATE STAIR WITH INTEGRATED GUARD AND HANDRAIL. PAINT P-3 - SEE FINISH LEGEND AND
STRUCTURAL DRAWINGS
5.19 1 1/2" DIA. STEEL GUARD AT 42" AFF. WITH 1 1/2" DIA. STAINLESS STEEL HANDRAIL AT 36" AFF. - RAILING TO BE WELDED
TO TOP OF STEEL STAIR STRINGER. PAINT P-3 - SEE FINISH LEGEND
5.23 WALL MOUNTED LADDER WITH FALL ARREST SYSTEM AND SECURITY DOOR
5.24 WALL LADDER - SECURE TO EXISTING STRUCTURE
9.41 PAINT MECHANICAL DUCTWORK P-3. TYPICAL ALL DUCTWORK AT STAGE - SEE FINISH LEGEND
27.01 RIGGING - SEE TECHNOLOGY DRAWINGS
27.02 LOFT BLOCKS - SEE TECHNOLOGY DRAWINGS
1/4" = 1'-0"
INTERIOR ELEVATION AT STAGE 1/4" = 1'-0"
INTERIOR ELEVATION AT STAGE
QUANTIFIED KEYNOTES - TOTALS
# KEYNOTE
≈ LINEAR
FEET
≈ SQUARE
FEET
TOTAL
LOCATIONS
04.3-T.O. ROOF
1768' - 10 1/4"
02.1-BACK LEVEL 2
1728' - 4"
01.1-STAGE
1717' - 6"
05-RAFTERS
1772' - 5"
00.1-ORCHESTRA PIT
1711' - 11"
04.2-ATTIC
1756' - 0"
9.08
9.09P35
P36
TYP
5.01
TYP
5.01
9.09 P35
TYP
9.07P32
TYP
9.07
P35
P34
TYP
9.07P34
9.01
P33
9.10 P32
9.10P32
9.01
P33
P35
9.08P36
TYP
9.07 P40
TYP
9.07P40
02.3 BOH T.O. ROOF
1737' - 4"
265 L.F. ±
265 L.F. ±
265 L.F. ±
55 L.F. ±
55 L.F. ±
9.07
50 S.F. ±
50 S.F. ±
9.10
5.13
TYP
12.01
TYP
12.01
AUDITORIUM
BALCONY
27.05
27.05 27.05
27.05 27.05
P435.01 5.17 P435.019.23 P429.249.219.23 P42 P42 P42 9.33 P439.33 P43
TYP
9.25 P45
TYP
9.25P45
AE501
ATTIC
9.39
26.02 26.02
9.36
AE501
C4 C4
C10
23.0223.02
LEGEND
X EXISTING CONDITION PHOTO NUMBER - SEE SHEETS AE700, AE701 & AE702
X
WINDOW TYPE - SEE SHEET AE603 - TYPICAL WINDOW ELEVATIONS FOR RESTORATION SCOPE
DOOR NUMBER - SEE SHEET AE602 - TYPICAL DOOR ELEVATIONS FOR RESTORATION SCOPE
CX CURTAIN TYPE - SEE SHEET AE605 - TYPICAL CURTAIN ELEVATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:0
P M
AE420
BUILDING SECTION - AUDITORIUM
05/30/2025 SPS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
DRAWING NOTES:
5.01 REMOVE EXISTING BRASS RAILING, CLEAN AND POLISH BACK TO ORIGINAL FINISH - REINSTALL IN EXISTING LOCATION
5.13 GALVANIZED METAL ACCESS LADDER - SECURE TO EXISTING WALL AND FLOOR STRUCTURE
5.17 1 1/2" DIA. BRASS RAILING AT 36" A.F.F. AT ORCHESTRA PIT - INSTALL IN ORIGINAL LOCATION
9.01 REMOVE ALL EXISTING CHIPPED, BLISTERED, ETC. DAMAGED WALL SURFACE. ALL EXISTING SURFACES TO RECEIVE
NEW SKIM COAT FINISH. PAINT P-1 - SEE FINISH LEGEND
9.07 REMOVE ALL BLISTERED AND PEELING PAINT. REPAIR DAMAGES TO PLASTER TRIM IN PLACE. PAINT P-2 - SEE FINISH
LEGEND
9.08 CLEAN PLASTER ORNAMENTATION AT STAGE OPENING PER MATERIAL STANDARD REQUIREMENT'S.
9.09 CLEAN PLASTER BALCONY ORNAMENTATION
9.10 REMOVE ALL BLISTERED AND PEELING PAINT. REPAIR DAMAGES TO PLASTER WALL SURFACE IN PLACE. PAINT P-2 - SEE
FINISH LEGEND
9.21 REMOVE EXISTING FINISH FROM ALL WHITE BEAD BOARD WALLS / COVE - PATCH / REPAIR AREAS OF DAMAGE AS NEEDED TO ACHIEVE ORIGINAL DESIGN - PAINT P-1 - SEE FINISH LEGEND - SEE ELECTRICAL DRAWINGS FOR POWER
REPLACEMENT IN THIS AREA
9.23 REMOVE EXISTING FINISH FROM LOUVER - PAINT TO MATCH EXISTING COLOR AND FINISH - SEE MECHANICAL DRAWINGS
9.24 REMOVE EXISTING FINISH FROM ALL STAINED WOOD AND TRIM AT FRONT STAGE LIP- PATCH / REPAIR AREAS OF DAMAGE AS NEED TO ACHIEVE ORIGINAL DESIGN - STAIN TO MATCH EXISTING COLOR AND FINISH
9.25 REFINISH EXISTING WOOD BEAD BOARD AND TOP CAP - PATCH / REPAIR AREAS OF DAMAGE AS NEEDED TO ACHIEVE
ORIGINAL DESIGN - STAIN TO MATCH EXISTING COLOR AND FINISH
9.33 REMOVE EXISTING FINISH FROM ALL STAINED WOOD. PATCH / REPAIR AREAS OF DAMAGE AS NEEDED TO ACHIEVE
ORIGINAL DESIGN - STAIN ST-1 - SEE FINISH LEGEND
9.36 VELCRO AT EDGE OF CURTAIN (CRT-1) FOR OPENING TO NEW ORCHESTRA PIT STAIR - SEE FINISH LEGEND
9.39 MAIN STAGE CURTAIN. FABRIC TO BE CRT-1 - SEE FINISH LEGEND AND AV DRAWINGS
12.01 REFURBISH EXISTING THEATER SEATING. REUPHOLSTER CHAIR BACKS AND SEAT CUSHIONS (FAB-1). STRIP AND CLEAN EXISTING PAINT AND REPAINT METAL COMPONENTS OF SEATING (TBD). STRIP AND CLEAN WOOD COMPONENTS OF SEATING PRIOR TO RE-STAINING AND RE-INSTALLATION(TBD). REINSTALL REFURBISHED SEATS BACK TO ORIGINAL LOCATION IN CORRECT SEQUENTIAL ORDER IF REMOVED AS PART OF NEW WORK. PROVIDE NEW FUNCTIONAL SEAT HARDWARE TO RESTORE TYPICAL OPERATION TO ALL SEATS. AISLE SEATS CONTAIN INTEGRAL FOOTLIGHTING.
COORDINATE WITH ELECTRICAL DRAWINGS FOR NEW WIRING AND FIXTURE TYPE. ASSUME 25% OF AISLE SEAT
INTERIOR LIGHT COVERS ARE MISSING AND WILL BE REPLACED.
23.02 DIFFUSER - SEE MECHANICAL DRAWINGS
26.02 SURFACE MOUNTED 6" DIAMETER SCONCE - SEE ELECTRICAL DRAWINGS
27.05 LOUDSPEAKER - SEE AUDIO-VISUAL AND TECHNOLOGY DRAWINGS
1/4" = 1'-0"
BUILDING SECTION AT AUDITORIUM
QUANTIFIED KEYNOTES - TOTALS
# KEYNOTE
≈ LINEAR
FEET
≈ SQUARE
FEET
TOTAL
LOCATIONS
9.07 REMOVE ALL BLISTERED AND PEELING PAINT. REPAIR DAMAGES TO PLASTER
TRIM IN PLACE. PAINT P-2 - SEE FINISH LEGEND
1195 0 0
9.10 REMOVE ALL BLISTERED AND PEELING PAINT. REPAIR DAMAGES TO PLASTER
WALL SURFACE IN PLACE. PAINT P-2 - SEE FINISH LEGEND
0 320 0
02.2-BALCONY
1733' - 6"
04.3-T.O. ROOF
1768' - 10 1/4"
02.1-BACK LEVEL 2
1728' - 4"
01.1-STAGE
1717' - 6"
05-RAFTERS
1772' - 5"
00.1-ORCHESTRA PIT
1711' - 11"
03-BOOTH
1740' - 9"
04.2-ATTIC
1756' - 0"
6.09 6.09
9.07
TYP
9.09
P39
P35
TYP
9.07 P32
TYP
9.07 P34
TYP
9.07P34
5.01
P35 5.01
P35
9.01
P33
P37
9.01
P37
9.10 P32 9.10P32
TYP
9.07
P40
TYP
9.07
P40
02.3 BOH T.O. ROOF
1737' - 4"
9.07
30 L.F. ±30 L.F. ±
265 L.F. ±
265 L.F. ±
265 L.F. ±
30 S.F. ±30 S.F. ± 9.10
TYP
12.01
TYP
12.01
BALCONY
AUDITORIUM
27.03
TYP
27.04
100E100F 100D
TYP
27.05
TYP
27.04
5.08
5.08
9.33P449.33P44
TYP
9.25
P45
TYP
9.25
P45
ATTIC
2.88
2.88
8.03
6.36
TYP
26.11
TYP
26.11TYP
26.11
TYP
26.11
9.01
TYP
26.11
TYP
26.11
TYP
27.04
C8 C8
LEGEND
X EXISTING CONDITION PHOTO NUMBER - SEE SHEETS AE700, AE701 & AE702
X
WINDOW TYPE - SEE SHEET AE603 - TYPICAL WINDOW ELEVATIONS FOR RESTORATION SCOPE
DOOR NUMBER - SEE SHEET AE602 - TYPICAL DOOR ELEVATIONS FOR RESTORATION SCOPE
CX CURTAIN TYPE - SEE SHEET AE605 - TYPICAL CURTAIN ELEVATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/ F
F E
M t H o m e
T h e a te r_ B
A
R C
H rv t
/1
/2
:1
:5
P M
AE421
BUILDING SECTION - AUDITORIUM
05/30/2025 SPS CD
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: Owner
DRAWING NOTES:
2.88 EXISTING SIDELIGHT BOOM TO REMAIN - PAINT P-3 - SEE FINISH LEGEND
5.01 REMOVE EXISTING BRASS RAILING, CLEAN AND POLISH BACK TO ORIGINAL FINISH - REINSTALL IN EXISTING LOCATION
5.08 1 1/2" DIA. BRASS HANDRAIL AT 36" AFF. - RAIL STYLE AND MOUNTINGS TO MATCH EXISTING BRASS RAILING
6.09 WOOD STAIR - STAIR TREADS AND RISERS TO BE CARPETED WITH CPT-1 - SEE FINISH LEGEND
6.36 INFILL EXISTING OPENING AND REMOVE BOXED OUT TRIM ON AUDITORIUM SIDE - FINISH OUTSIDE SURFACE FLUSH TO
EXISTING WALL SURFACE - FINISH TO MATCH EXISTING COLOR AND SHEEN
8.03 CASEMENT WINDOW - SIZE TO MATCH EXISTING OPENING
9.01 REMOVE ALL EXISTING CHIPPED, BLISTERED, ETC. DAMAGED WALL SURFACE. ALL EXISTING SURFACES TO RECEIVE
NEW SKIM COAT FINISH. PAINT P-1 - SEE FINISH LEGEND
9.07 REMOVE ALL BLISTERED AND PEELING PAINT. REPAIR DAMAGES TO PLASTER TRIM IN PLACE. PAINT P-2 - SEE FINISH
LEGEND
9.09 CLEAN PLASTER BALCONY ORNAMENTATION
9.10 REMOVE ALL BLISTERED AND PEELING PAINT. REPAIR DAMAGES TO PLASTER WALL SURFACE IN PLACE. PAINT P-2 - SEE
FINISH LEGEND
9.25 REFINISH EXISTING WOOD BEAD BOARD AND TOP CAP - PATCH / REPAIR AREAS OF DAMAGE AS NEEDED TO ACHIEVE
ORIGINAL DESIGN - STAIN TO MATCH EXISTING COLOR AND FINISH
9.33 REMOVE EXISTING FINISH FROM ALL STAINED WOOD. PATCH / REPAIR AREAS OF DAMAGE AS NEEDED TO ACHIEVE
ORIGINAL DESIGN - STAIN ST-1 - SEE FINISH LEGEND
12.01 REFURBISH EXISTING THEATER SEATING. REUPHOLSTER CHAIR BACKS AND SEAT CUSHIONS (FAB-1).
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .