Atch 10_621-24-103 Drawing part 5 of 6.pdf
PDF 34 MB Posted
- Solicitation number
- 36C24926R0055
About this file
This file contains plumbing and fire suppression design drawings and specifications for the Restoration of Building 35 Historic Theater (Project 621-24-103) at the James H. Quillen VA Medical Center in Mt. Home, Tennessee. The drawings include abbreviations and legends, foundation and basement demolition plans, first and second floor demolition plans, plumbing site plans, foundation and basement new work plans, first and second floor new work plans, enlarged plans, details and schedules, drainage and distribution isometrics, and theater systems symbols and schedules. Key plumbing work includes removal and replacement of domestic water piping and sanitary drain systems, installation of new backflow preventers, pressure reducing valves, thermostatic mixing valves, recirculation pumps, and expansion tanks. The plans specify installation of water closets, urinals, lavatories, sinks, drinking fountains, floor drains, and wall hydrants throughout the building. Storm drainage improvements include new 8-inch storm piping connections and scupper drains. Notable requirements include coordination with mechanical and electrical trades due to limited ceiling space in back-of-house areas, freeze protection for below-floor piping, water detection sensors with alarm systems, hard-wired heat trace controllers, and compliance with VA design manuals and local water safety protocols. Fire suppression systems include dry-pipe and wet-pipe risers, fire department connections and valves, hose stations, and full sprinkler coverage. The drawings are dated July 1, 2025, and represent bid documents for the project, with specifications referencing ASME standards, NFPA codes, and UL-listed equipment.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-BASEMENT
1707' - 6"
02.1-BACK LEVEL 2
1728' - 4"
05-RAFTERS
1772' - 5"
04.2-ATTIC
1756' - 0"
NP-1
FDC
TO BUILDING
TO BACK-OF-HOUSE
TO AUDITORIUM ATTIC
& BELOW CATWALK
EXISTING 6" INCOMING FIRE
SERVICE
S S
MECH/ELEC ROOM
DOUBLE CHECK
DETECTOR ASSEMBLY
DRY-PIPE VALVE
ASSEMBLY
S
AIR PRESSURE SWITCH
WET-PIPE TO SERVE
HOSE STATIONS
AND FDV'S
TO ABOVE STAGE
ATTIC SPRINKLERS
D S
D S
D S
CHECK VALVE
F201
CATWALK
LADDER
TO BELOW STAGE
ATTIC SPRINKLERS
00-BASEMENT
1707' - 6"
02.1-BACK LEVEL 2
1728' - 4"
01.1-STAGE
1717' - 6"
04.2-ATTIC
1756' - 0"
CATWALK
DRY-PIPE RISER.
FDV
FDV
WET STANDPIPE
00-BASEMENT
1707' - 6"
02.1-BACK LEVEL 2
1728' - 4"
01.1-STAGE
1717' - 6"
04.2-ATTIC
1756' - 0"
F201
FDV
TO BACK-OF-HOUSE
TO AUDITORIUM ATTIC
& BELOW CATWALK
TO ABOVE STAGE
ATTIC SPRINKLERS
CATWALK
LADDER
TO BELOW STAGE
ATTIC SPRINKLERS
TO AUDITORIUM ATTIC
FDV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:2
:0
P M
F201
SECTIONS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTSJAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
SCALE: 1/4" = 1'-0"
FIRE SERVICE ENTRANCE DRY-PIPE
SCALE: 1/4" = 1'-0"
WEST CATWALK
PLAN NOTES
1. COORDINATE CLOSELY WITH MECHANICAL EQUIPMENT AND STAIR/ LADDER TO ACCESS CATWALKS.
REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
SCALE: 1/4" = 1'-0"
EAST CATWALK
BID DOCUMENTS 07/01/2025
GENERAL PROJECT NOTES
A ALL NEW PIPING IS AT THE UNDERSIDE OF STRUCTURE IN EXPOSED STRUCTURE
AREAS, UNLESS OTHERWISE NOTED.
ABOVE CEILING UTILITY SPACE IS LIMITED (BACK OF HOUSE).
COORDINATION WITH ALL TRADES IS CRITICAL, (IN ALL AREAS) PRIOR TO
INSTALLATION OF ANY WORK.
B REFER TO SCHEDULES, DETAILS AND DIAGRAMS FOR PIPING, PIPE SIZES AND
PIPELINE DEVICES NOT INDICATED ON THE FLOOR PLAN.
C LOCATIONS AND SIZES OF EXISTING PIPING HAVE BEEN DETERMINED FROM A
REVIEW OF EXISTING DRAWINGS AND/ OR SITE INSPECTION, WHERE POSSIBLE.
FIELD VERIFICATION OF EXACT LOCATIONS, ELEVATIONS, INVERTS, SIZES,
DIRECTION OF FLOW, ETC. SHALL BE REQUIRED PRIOR TO BEGINNING NEW
WORK.
D ALL DOMESTIC WATER PIPING SHOWN TO BE DEMOLISHED SHALL BE REMOVED
BACK TO WITHIN TWO PIPE DIAMETERS OF ACTIVE MAINS AND CAPPED, OR
REMOVED BACK TO POINTS OF CONNECTION OF NEW WORK. INACCESSIBLE
PIPING, WHERE SO NOTED, TO BE ABANDONED SHALL BE DISCONNECTED
FROM ACTIVE MAINS AND CAPPED IN CONCEALED LOCATIONS.
E ABANDONED PIPING DISCOVERED DURING DEMOLITION/ RENOVATION
SHALL BE REMOVED.
F ALL REMOVED MATERIAL AND EQUIPMENT SO DESIGNATED BY THE COR,
SHALL BE TURNED OVER AND PLACED WHERE DIRECTED. ALL MATERIAL AND
EQUIPMENT, WHICH THE OWNER DOES NOT WISH TO RETAIN, SHALL BECOME
THE PROPERTY OF THE CONTRACTOR RESPONSIBLE FOR THE REMOVAL.
G ALL CORE DRILLS AND PIPE EXTENSIONS THRU THE EXISTING STRUCTURAL
FLOOR SLAB OR STRUCTURAL WALL SHALL BE X-RAYED TO DETERMINE THE
EXACT LOCATION OF THE "REBARS" IN THE STRUCTURAL SLAB. DO NOT CUT
THE LOWER (BOTTOM REBARS) IN THE FLOOR SLAB.
H REFER TO ARCHITECTURAL FIRE RATED PARTITION PLAN(S) FOR LOCATIONS
AND FIRE RATINGS OF NEW AND EXISTING WALL ASSEMBLIES. ALL
PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE PROTECTED
AND/ OR FIRE STOPPED AS REQUIRED TO MAINTAIN FIRE RATINGS INDICATED.
COORDINATE WITH ALL TRADES TO ENSURE FIRE RATED PENETRATION
REQUIREMENTS AND DETAILS ARE MET.
I ANNULAR SPACE OF ALL PIPE & OTHER SIMILAR PENETRATIONS OF FIRE RATED
ASSEMBLIES SHALL BE FIRE STOPPED. IN ADDITION, PENETRATIONS THROUGH
0-HOUR RATED WALLS & FLOOR SHALL BE SEALED TO RETARD THE PASSAGE
OF SMOKE.
M DOMESTIC WATER PIPING INSTALLED BY THIS PROJECT SHALL BE DISINFECTED
AND TESTED IN ITS ENTIRETY. DISINFECTION AND TESTING PROCEDURES SHALL
FOLLOW CAMPUS VA WATER SAFETY PLAN, VA DESIGN MANUALS,
VA SPECIFICATIONS, AND LOCAL REQUIREMENTS.
A1
P1 P1OR
A1
OH
P2
B
P2
GENERAL FLOOR PLAN NOTES
RISER OR STACK NUMBER
DETAIL: B = DETAIL DESIGNATION
P2 = SHEET WHERE DETAIL IS LOCATED
FIRE SUPPRESSION HAZARD CLASSIFICATION AND
HAZARD CLASSIFICATION GROUP
SECTION: 1 = SECTION DESIGNATION
P2 = SHEET WHERE DETAIL IS LOCATED
EQUIPMENT REFERENCE. LETTER DESIGNATION
VARIES. REFER TO SCHEDULES.
EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK.
LETTER DESIGNATIONS REFER TO SCHEDULES.
CONNECT TO EXISTING
PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH
IT IS SHOWN UNLESS NOTED OTHERWISE.
DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.
"UP TO" SYMBOL (ITEM ON FLOOR ABOVE)
PIPING DESIGNATIONS
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
EXISTING PIPE TO REMAIN
EXISTING PIPE TO BE REMOVED
HOT WATER PIPE (140 DEGS. F.)
HOT WATER RETURN PIPE (140 DEGS. F.)
HOT WATER RETURN PIPE (180 DEGS. F.)
140R
180R
EXPANSION JOINT
WATER METERM
PIPING SYMBOLS
BOTTOM CONNECTION (45°)
BRANCH TEE CONNECTION (NOTE:
BULLHEAD TEE'S ARE NOT PERMITTED)
DIRECTION OF PITCH
DROP
ELBOW DOWN
ELBOW UP
FLOW DIRECTION DESIGNATION
PUMP
RISE
TOP CONNECTION (45°)
TOP CONNECTION (90°)
BOTTOM CONNECTION (90°)
D
R
PIPE RISER
HOT WATER PIPE (180 DEGS. F.)
COMPRESSED AIR PIPE
GARAGE DRAINAGE PIPE
KITCHEN WASTE PIPE
NON-POTABLE
(OVERFLOW) SECONDARY STORM DRAINAGE PIPE
PUMP DISCHARGE PIPE
PURE WATER PIPE
SANITARY DRAINAGE PIPE
SOFT COLD WATER
STORM DRAINAGE PIPE
TRAP PRIMER DISCHARGE PIPE
TEMPERED WATER PIPE
SANITARY SEWER VENT
WATER SERVICE
CA
GD
IV
IW
NPW
OD
PD
PW
SAN
SCW
STM
TP
TW
V
WS
INDIRECT VENT PIPE
INDIRECT WASTE PIPE
K
ACID VENT PIPEAV
ACID WASTE PIPEAW
BC
TC
COMBINATION FIRE SUPPRESSION &
DOMESTIC WATER SERVICE
CWS
FLEX PIPING
VALVES AND FITTINGS
T
P
FOB
FOT
CONCENTRIC PIPE REDUCER
ECCENTRIC PIPE REDUCER
GAUGE - PRESSURE
GAUGE - TEMPERATURE OR THERMOMETER
UNION
CLEANOUT
STRAINER
STRAINER - WITH A BLOW DOWN VALVE AND HOSE
CONNECTION
VALVE - DRAIN WITH HOSE END CONNECTION
VALVE - PRESSURE REGULATING
VALVE - SAFETY RELIEF. PIPE DISCHARGE AIR
GAPPED TO FLOOR DRAIN UNLESS NOTED
OTHERWISE.
PLUG - PRESSURE AND TEMPERATURE TEST
TRAP PRIMER
GAUGE - VACUUM WITH STOP
CLEANOUT - TO GRADE OR FINISHED FLOOR
END CAP
MIXING FAUCET
PLUG
HOSE BIB
WALL HYDRANT
VALVE - PLUG
VALVE - SHUTOFF AND BOX
VALVE - SHUTOFF ON RISER
V
VB
TP
CO
VALVE - SOLENOID
S
P/T VALVE - PRESSURE AND TEMPERATURE SAFETY
RELIEF. PIPE DISCHARGE AIR GAPPED TO
FLOOR DRAIN UNLESS NOTED OTHERWISE.
VALVE - CHECK
VALVE - SHUTOFF: BALL, GATE, BUTTERFLY VALVE
(REFER TO SPECIFICATIONS FOR REQUIRED TYPE
BASED ON APPLICATIONS)
AUTOMATIC FLOW CONTROLLER WITH P/T PLUG IN
AND OUT
VALVE - COMBINATION SHUTOFF AND
BALANCING (REFER TO SPECIFICATIONS FOR
REQUIRED TYPE BASED ON APPLICATIONS)
ABBREVIATIONS
AAP - AREA ALARM PANEL (MEDICAL GAS)
AC - AIR COMPRESSOR OR AIR CONDITIONER
ACC - ACCESS
ACCU - AIR COOLED CONDENSING UNIT
AD - ACCESS DOOR OR AREA DRAIN
ADB - ACID DILUTION BASIN
ADJ - ADJUSTABLE
AFF - ABOVE FINISHED FLOOR
AFG - ABOVE FINISHED GRADE
ALT - ALTERNATE
AP - ACCESS PANEL
APPROX - APPROXIMATE
AR - AIR RECEIVER OR ARGON
ARCH - ARCHITECT OR ARCHITECTURAL
ASSY - ASSEMBLY
AV - ACID VENT
AW - ACID WASTE
BDD - BACK DRAFT DAMPER
BFP - BACKFLOW PREVENTER
BLDG - BUILDING
BOB - BOTTOM OF BEAM
BOD - BOTTOM OF DUCT
BOE - BOTTOM OF EQUIPMENT
BOF - BOTTOM OF FOOTING
BOG - BOTTOM OF GRILLE
BOP - BOTTOM OF PIPE
BOT - BOTTOM
BT - BATHTUB
BTU - BRITISH THERMAL UNIT
BTUH - BRITISH THERMAL UNIT PER HOUR
BTWN - BETWEEN
CA - COMPRESSED AIR
CB - CATCH BASIN
CBD - COUNTER BALANCED BACKDRAFT DAMPER
CFCI - CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CFM - CUBIC FEET PER MINUTE
CHS - CHILLED WATER SUPPLY
CHR - CHILLED WATER RETURN
CI - CAST IRON
CK - CLINICAL SINK
CLG - CEILING
CMU - CONCRETE MASONRY UNIT
CO - CLEAN OUT
CO2 - MEDICAL CARBON DIOXIDE
CONN - CONNECT OR CONNECTION
CONTR - CONTRACTOR
COR - CONTRACTING OFFICER'S REPRESENTATIVE
CORR - CORRIDOR
CRP - CORROSION RESISTANT PIPE
CRV - CORROSION RESISTENT VENT PIPE
CS - CLINICAL SINK OR COLD SOFT WATER
CTR - CENTER
CU - COPPER
CW - COLD WATER
CWS - COMBINATION WATER SERVICE
OR CONDENSER WATER SUPPLY
CWR - CONDENSER WATER RETURN
D - DEPTH OR DRAIN LINE
DB - DIALYSIS BOX
DD - DECK DRAIN
DET - DETAIL
DF - DRINKING FOUNTAIN OR WATER COOLER
OR DIESEL FUEL
DFU - DRAINAGE FIXTURE UNIT
DI - DEIONIZED WATER
DIA - DIAMETER
DIM - DIMENSION
DN - DOWN
DS - DOWN SPOUT OR SPRINKLER (DRY)
DT - PERFORATED DRAIN TILE
DWG - DRAWING
EA - EACH
EC - ELECTRICAL (DIVISION 26)
EEW - EMERGENCY EYE WASH
EJ - EXPANSION JOINT
ELEC - ELECTRICAL
ELEV - ELEVATOR
EQ - EQUAL
EQUIP - EQUIPMENT
ET - EXPANSION TANK
ETR - EXISTING TO REMAIN
ES - EMERGENCY SHOWER
EQS - EQUIPMENT SUPPLIER
EWC - ELECTRICAL WATER COOLER
EXH - EXHAUST AIR
EXP - EXPANSION
EXT - EXTERIOR
EX - EXISTING
F - FIRE SUPPRESSION (STANDPIPE/SPRINKLER
MAIN)
FCE - FIRE CONTROL EQUIPMENT
FCO - FLOOR CLEANOUT
FD - FLOOR DRAIN
FDC - FIRE DEPARTMENT CONNECTION
FDV - FIRE DEPARTMENT VALVE
FF - FINISHED FLOOR ELEVATION
FHC - FIRE HOSE CABINET
FLR - FLOOR
FM - FORCE MAIN
FOB - FLAT ON BOTTOM
FOF - FUEL OIL FLOW
FOG - FUEL OIL GAUGE
FOR - FUEL OIL RETURN
FOS - FUEL OIL SUPPLY
FOT - FLAT ON TOP
FPM - FEET PER MINUTE
FR - FIRE RISER
FS - FLOOR SINK OR FIRE SERVICE
FSC - FIRE SUPPRESSION (DIVISION 21)
FT - FEET
FTG - FOOTING
G - GAS OR NATURAL GAS
GA - GAUGE
GAL - GALLON
GALV - GALVANIZED
GC - GENERAL TRADES (DIVISION 01)
GD - GARAGE DRAINAGE
GPM - GALLONS PER MINUTE
GS - GAS SERVICE
GW - GREASE WASTE
H2 - HYDROGEN
HB - HOSE BIBB
HC - HVAC (DIVISION 23)
HD - HUB DRAIN
HE - HELIUM
HG - REFRIGERANT HOT GAS
HP - HORSEPOWER OR HIGH POINT
HPC - HIGH PRESSURE CONDENSATE RETURN
HPS - HIGH PRESSURE STEAM SUPPLY
HPW - HIGH PURITY WATER
HPWR - HIGH PURITY WATER RETURN
HR - HOSE REEL
HT - HEAT TRACE
HTR - HEATER
HVAC - HEATING, VENTILATING, AND AIR
CONDITIONING
HW - HOT WATER
HWR - HEATING HOT WATER RETURN
HWS - HEATING HOT WATER SUPPLY
IA - MEDICAL INSTRUMENT AIR
ID - INSIDE DIAMETER
INV - INVERT ELEVATION
IN - INCHES
IV - INDIRECT VENT
IW - INDIRECT WASTE
JS - JANITOR SINK
K - KITCHEN WASTE
KEC - KITCHEN EQUIPMENT
L - LENGTH
LA - LABORATORY COMPRESSED AIR
LAV - LAVATORY
LBS - POUNDS
LCW - LABORATORY COLD WATER
LEC - LABORATORY EQUIPMENT
LHW - LABORATORY HOT WATER
LHWR - LABORATORY HOT WATER RETURN
LPC - LOW PRESSURE CONDENSATE RETURN
LPS - LOW PRESSURE STEAM SUPPLY
LV - LABORATORY VACUUM OR LABORATORY
VENT
LW - LABORATORY WASTE
MA - MEDICAL COMPRESSED AIR
MAP - MASTER ALARM PANEL (MEDICAL GAS)
MAX - MAXIMUM
MB - MOP BASIN
MC - MECHANICAL (DIVISION 23)
MEZZ - MEZZANINE
MFR - MANUFACTURER
MH - MANHOLE
MIN - MINIMUM OR MINUTE
MISC - MISCELLANEOUS
MTD - MOUNTED
MTG - MOUNTING
MPC - MEDIUM PRESSURE CONDENSATE RETURN
MPS - MEDIUM PRESSURE STEAM SUPPLY
MU - WATER MAKE-UP
MV - MEDICAL SURGICAL VACUUM
N2 - MEDICAL NITROGEN
N/C - NORMALLY CLOSED
NG - GASOLINE (NON-LEAD)
NIC - NOT IN CONTRACT
N/O - NORMALLY OPEN
NO - MEDICAL NITROUS OXIDE
NOM - NOMINAL
NPW - NON-POTABLE WATER
NPT - NATIONAL PIPE THREAD
NTS - NOT TO SCALE
O2 - MEDICAL OXYGEN
OA - OUTDOOR AIR
OD - OUTSIDE DIAMETER OR OVERFLOW
DRAIN
OFCI - OWNER FURNISHED CONTRACTOR
INSTALLED
OFOI - OWNER FURNISHED OWNER INSTALLED
P - PROPANE GAS
PC - PLUMBING (DIVISION 22) OR PUMPED
CONDENSATE RETURN
PD - PUMP DISCHARGE OR PARAPET DRAIN
PIV - POST INDICATOR VALVE
PLBG - PLUMBING
PS - PRE-ACTION/DELUGE SPRINKLER
PRESS - PRESSURE
PRV - PRESSURE REGULATING VALVE
PSF - POUNDS PER SQUARE FOOT
PSI - POUNDS PER SQUARE INCH
PSV - PRESSURE SUSTAINING VALVE
PSIG - POUNDS PER SQUARE INCH GAUGE
PW - PURE WATER
RA - RETURN AIR
RAD - RADIUS
RCP - REINFORCED CONCRETE PIPE
RD - ROOF DRAIN
REC - RECESSED
REQD - REQUIRED
RI - ROUGH IN
RL - REFRIGERANT LIQUID
ROS - REVERSE OSMOSIS WATER SUPPLY
ROR - REVERSE OSMOSIS WATER RETURN
RPM - REVOLUTIONS PER MINUTE
RS - REFRIGERANT SUCTION
RV - RELIEF VALVE
S - SPRINKLER (WET)
SA - SHOCK ARRESTOR OR SUPPLY AIR
SAN - SANITARY OR SANITARY DRAIN
SCH - SCHEDULE
SCW - SOFT COLD WATER
SD - SPRINKLER DRAIN OR SUBSOIL DRAIN
SH - SHOWER
SHT - SHEET
SK - SINK
SPEC - SPECIFICATIONS
SQ - SQUARE
SR - SUPPLY RISER
SS - SANITARY STACK (SOIL OR WASTE) OR
STAINLESS STEEL
STD - STANDARD
STM - STORM OR STORM DRAINAGE
STRUC - STRUCTURAL OR STRUCTURE
SUC - SITE UTILITY CONTRACTOR
T - FUEL TANK VENT
TD - TRENCH DRAIN
TEMP - TEMPERATURE
TOB - TOP OF BEAM
TOD - TOP OF DUCT
TOE - TOP OF EQUIPMENT
TOF - TOP OF FOOTING
TOJ - TOP OF JOIST
TOP - TOP OF PIPE
TOS - TOP OF SLAB OR TOP OF STEEL
TF - TRAP FILLER
TP - TRAP PRIMER OR TRAP PRIMER
DISCHARGE
TW - TEMPERED WATER
TYP - TYPICAL
UR - URINAL
UNO - UNLESS NOTED OTHERWISE
V - VENT OR SANITARY SEWER VENT
VAC - VACUUM
VC - VACUUM CLEANING
VCV - VACUUM CLEANING VALVE
VE - VACUUM EXHAUST
VEL - VELOCITY
VIB - VALVE IN BOX
VOL - VOLUME
VP - VACUUM PUMP
VS - VENT STACK
VTR - VENT THROUGH ROOF
VR - VENT RISER
W/ - WITH
W/O - WITHOUT
W - WASTE
WAGD - WASTE ANESTHESIA GAS DISPOSAL
WC - WATER CLOSET
WCO - WALL CLEANOUT
WH - WALL HYDRANT OR WATER HEATER
WIV - WALL INDICATOR VALVE
WS - WATER SERVICE
YCO - YARD CLEANOUT
ZVC - ZONE VALVE CABINET
DEMOLISH TO POINT INDICATED
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:0
P M
P001
ABBREVIATIONS, LEGEND &
GENERAL NOTES
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
DRAWING INDEX
SHEET
NUMBER SHEET NAME
P001 ABBREVIATIONS, LEGEND & GENERAL NOTES
PD101 FOUNDATION AND BASEMENT DEMOLITION PLANS
PD102 FIRST AND SECOND FLOOR DEMOLITION PLANS
PS100 PLUMBING SITE PLAN
PP101 FOUNDATION AND BASEMENT NEW WORK PLANS
PP102 FIRST AND SECOND FLOOR NEW WORK PLANS
P401 ENLARGED PLANS
P601 DETAILS AND SCHEDULES
P901 DRAINAGE ISOMETERIC
P902 DISTRIBUTION ISOMETERIC
BFPBFP
UP4" SAN 1
S A
N
6"
UP2" SAN
SP
UP4" SAN 1
BELOW GRADE
PIPING. TYPICAL.
MECH/ELEC ROOM
MECH/ELEC ROOM
ELECTRICAL ROOM
MECH/ELEC ROOM
SP
WC
UR
WC
LAV
WC2
SK 2
LAV
LAV
2SH2
LAV
LAV
DN4" SAN
CO
CO
UP & DN4" SAN
DN2"
WC
DN2"3
DWH
DCW
D C
W
DCW
LAV
SK 2"
1.5"
TYP.
TYP.
TYP.
TYP.
TYP.
DF 20.5"
1.5" 0.5"
4" 2"
DN4" SAN
UNEXCAVATEDUNEXCAVATED
WH 2
6"
S A
N
FD
DCW
DHW
D C
W
WATER SERVICE ENTRANCE
TYP.
TYP.
D C
W D
H W
S A
N
0.75"
DCW
BELOW FLOOR ACCESS
3"
W S
OPEN WOODEN SUPPORT STRUCTURE
SHEET NOTES
A. REFER TO SHEET P001 FOR ABBREVIATIONS, LEGEND & GENERAL PROJECT NOTES.
B. BELOW GRADE/ UNEXCAVATED SPACE SANITARY PIPING TO BE JETTED AND VISUALLY INSPECTED TO CLEAR
AND IDENTIFY COMPROMISED PIPING. REPORT FINDINGS TO COR.
C. NON-POTABLE WATER PIPING AND BACK FLOW PREVENTERS SERVING MECHANICAL EQUIPMENT TO REMAIN.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:3
P M
PD101
FOUNDATION AND BASEMENT
DEMOLITION PLANS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:3
P M
PD101
FOUNDATION AND BASEMENT
DEMOLITION PLANS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
1/8" = 1'-0"
FOUNDATION DEMOLITION PLAN
1/8" = 1'-0"
BASEMENT DEMOLITION PLAN
PLAN NOTES
1. EXISTING PIPING OR ITEM OF EQUIPMENT (TYPE AS INDICATED) TO REMAIN.
2. REMOVE ALL EXISTING DOMESTIC WATER PIPING AND PIPING LINE DEVICES BACK TO EXISTING DOMESTIC WATER HEATER.
REMOVE EXISTING SANITARY DRAIN AND/ OR VENT PIPING BACK TO POINT OF NEW CONNECTION.
3. REMOVE DOMESTIC WATER BACK FLOW PREVENTERS, EXISTING PRESSURE REDUCING VALVE ARRANGEMENT AND ASSOCIATED PIPING AND PIPELINE DEVICES BACK TO POINT OF NEW CONNECTION. RECORD EXISTING PRESSURE REDUCING VALVE SETTING FOR USE ON NEW INSTALLATION. REFER TO VIEW B/ PD101 AND NEW WORK PLANS.
4. REMOVE EXISTING SANITARY PIPING TO BELOW GRADE AND CAP. REFER TO VIEW C/ PD101.
5. REMOVE EXISTING FLOOR DRAIN PLUG. PLUG DRAIN OUTLET AND FILL DRAIN WITH CONCRETE TO FLUSH WITH EXISTING
FLOOR SLAB. REFER VIEW A/ PD101.
6. PIPING CONTINUED ON CIVIL PLANS.
7. PUMPED DISCHARGE PIPING AND SUMP PUMP TO REMAIN.
8. REMOVE EXISTING SANITARY PIPING BACK TO POINT OF NEW CONNECTION.
NTS
A
ROOM 005 - FLOOR DRAIN
NTS
B
ROOM 001 - DOMESTIC BFP ARRANGEMENT
NTS
C
ROOM 003 - BASEMENT SANITARY
EXISTING BACK FLOW PREVENTER
EXISTING FLOOR DRAIN PLUG
EXISTING PRESSURE REDUCING VALVE
BID DOCUMENTS 07/01/2025BID DOCUMENTS 07/01/2025
UR
SK LAV
WC
WC
LAV
WC
SK
SH
WC
SK
LAV
LAV
LAV
UP & DN4" SAN
LOBBY
AUDITORIUM
STAGE
PROPERTY RM
BATHROOM
KITCHENETTE
TLT RM
DRESSING RM
DRESSING RM
DRESSING RM
EXISTING VENT RISER
EXISTING VENT RISER 1
WH
STAIRS REMOVED
FOR CLARITY
STAIRS REMOVED
FOR CLARITY
WC
LAV
LAV
LAV
LAV
UP & DN4" SAN
DRESSING RM
DRESSING RM
DRESSING RM
DRESSING RM
TLT RM
UP4" V
3"VTR
3"VTR
EXISTING ROOF
HATCH
ERV
ERV
EF
4"
SHEET NOTES
A. REFER TO SHEET P001 FOR ABBREVIATIONS, LEGEND & GENERAL PROJECT NOTES.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:4
P M
PD102
FIRST AND SECOND FLOOR
DEMOLITION PLANS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:4
P M
PD102
FIRST AND SECOND FLOOR
DEMOLITION PLANS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
1/8" = 1'-0"
FIRST FLOOR DEMOLITION PLAN
1/8" = 1'-0"
SECOND FLOOR DEMOLITION PLAN
PLAN NOTES
1. EXISTING PIPING OR ITEM OF EQUIPMENT (TYPE AS INDICATED) TO REMAIN.
2. REMOVE EXISTING FIXTURE OR ITEM OF EQUIPMENT (TYPE AS INDICATED) AND ALL ASSOCIATED DOMESTIC WATER PIPING BACK TO EXISTING DOMESTIC WATER HEATER. REMOVE ALL ASSOCIATED SANITARY DRAIN AND VENT PIPING BACK TO POINT OF
NEW CONNECTION OR BACK TO ACTIVE MAIN AND CAP.
3. REMOVE EXISTING SANITARY AND DCW PIPING FROM PREVIOUSLY REMOVED DRINKING FOUNTAIN.
4. REMOVE EXISTING POINT OF USE WATER HEATER.
5. REMOVE EXISTING SANITARY PIPING THRU ROOF. PATCH ROOF, SEAL WATER TIGHT.
6. BELOW FLOOR ACCESS.
7. EXISTING SCUPPER TO REMAIN. CLEAR OF ALL DEBRIS.
1/8" = 1'-0"
BACK ROOF DEMOLITION PLAN
NTS
A
EXTERIOR WATER HYDRANT
FF 1718.50'
M e m o r ia l A v e n u e
1714.59
1716.91
1714.89
1714.61
1714.60
1714.72 1714.78
1717.17
1716.78
1715.66
1714.58
1713.68
1714.28
1713.62
1713.43
1714.66
1717.45
1717.45
1718.0
1718.7
1718.3
1718.0
1717.9
1717.8
1717.7
1717.7 7 1717.7
1717.7
1717.6
1717.9
1717.9
1717.6
1717.19
1716.9
1716.3
1715.9
1715.5
1715.2
1715.2
1715.14
1713.8 61713.8
1713.8
1713.6
1713.3
1718.4
1717.6
1716.7
1715.8
1715.3
1715.3
1713.9
1713.4
1713.0
1717.3
1717.3
1716.7
1715.8
1715.8
1715.7
1715.7
1715.7
1715.6
1715.5
1715.7
1715.7
1715.5
1715.4
1715.6
1715.7
1715.3
1717.7
1715.4
1714.9
1715.0
1714.6
1717.3
1717.3
1717.3
1717.3
1714.5
1715.0
1714.9
1717.3
1717.3
1717.3
1717.3
1716.9
1717.5
1715.7
1715.7
1715.7
1715.7
1715.7
1715.7
1715.7
1715.7
1715.7
1715.2
1715.2
1718.5
1718.3
1718.0
1713.9
1715.3
1715.2
1715.3
1715.3
1715.2
1715.0
1715.0
1715.0
1713.7
1713.6
1713.7
1713.7
1718.6
1717.8
1716.9
1716.0
1715.0
1714.6
1713.9
1715.0
1714.8
1714.6
1714.9
1714.0
1714.6
1718.0
1717.9
1718.0
1718.3
1718.3
1718.17
1718.0
1718.0
1715.5
1715.3
1717.2
1717.3
1715.9
1717.4
1717.5
1715.2
1715.15
1715.0
1715.7
1715.6
1715.5
1715.5
1715.4
1717.5
1717.4
1715.2
1715.2
1715.19 1715.2
1717.4
1715.13 1715.17
1715.16
1715.14
1715.0
1717.4
1716.8
1716.6
1715.8
1715.0
1714.9
1715.0
1715.0
1715.0
1715.0
1715.16
1714.8
1713.4
1713.19
1713.2
1712.4
1712.7
1713.2
1713.6
1713.5
1713.7
1713.6
1713.7
1716.7
1716.7
1716.6
1716.6
1716.6
1716.7
1715.2
1715.0
1715.15 1715.14
1715.0
1715.0
1714.9
1714.8
1714.9
1714.4
1714.2
1714.2
1713.8
1713.6
1713.0
1713.0
1713.6
1714.2
1714.5
1714.5
1714.5
1714.19
1713.9
1713.7 7 1713.7
1713.7
1713.7
1714.3
1714.7
1714.7
1714.4
1714.5
1714.5
1714.5
1713.9
1714.5
1714.5
1714.4
1714.2
1714.10
1713.8
1713.6
1713.11
1717.8
1718.7
1718.7
1718.3
1717.9
1713.9
1713.9
1713.8
1713.7
1713.7
1713.7
1713.7
1715.6
1715.6
1716.5
1715.9 31716.4
1717.5
1716.8
1718.0
1717.6
1717.5
1717.6
1717.6
1717.5
1717.4
1717.3
1717.4
1717.4
1717.4
1717.4
1717.9
1718.0
1717.2
1716.8
1716.7
1715.9
1715.4
1715.2
1715.0
1715.0
1714.9
1713.8
1713.8
1713.7
1713.3
1712.9
1713.0
1718.3
1717.4
1716.5
1715.5
1715.0
1714.8
1713.4
1713.2
1712.8
1712.6
1712.6
1715.9
1715.16
1715.18
1715.6
1714.8
1715.0
1714.7
1712.7
1713.3
1713.8
1714.5
1714.2
1714.3
1717.8
1715.4
1716.9
1715.8
1715.8
1716.9
1717.5
1712.6
1712.9
1717.0
1716.8
1714.3
1715.5
1717.4
1717.4
1715.2
1717.8
1716.7 81716.7
1716.8
1716.8
1716.9
1716.8
1716.8
1715.2
1715.2
1715.2
1715.4
1711.4
1710.11
1715.19
1716.7
1718.0
1716.9
1717.5
1717.9
1717.4
1717.4
1713.7
1713.7
1712.7
1714.2
1714.8
1714.9
1712.7
1714.3
1714.8
1714.9
1715.0
1715.0
1714.8
1714.8
1714.9
1715.2
1714.0
1714.2
1714.2
1714.0
1714.0
1714.18
1714.2
1713.6
1713.0
1713.0
1712.7 71713.8
1714.0
1714.3
1714.8
1714.9
1717.8
1718.17
1715.2
1714.9
1714.8
1715.0
1715.2
1714.5
1714.9 01715.2
1715.3
1715.8 91716.5
1717.16
1717.6 01717.8
1717.8
1718.5
1719.0
1718.9
1718.0
1718.2
1717.8
1715.7
1715.7
1715.8
1715.8
1715.3
1715.11
1714.6
1718.3
1718.2
1718.0
1717.3
1716.8
1716.5
1716.2
1715.7
1715.6
1715.7
1715.10
1715.0
1715.2
1715.3
1718.2
1715.7
1715.6
1714.5
1714.4
1714.3
1714.2
1714.4
1714.8
1714.7
1714.6
1714.5
1715.7
1715.7
1715.7
1714.9
1714.9
1715.0
1716.2
1716.4
1718.3
1718.3
1718.4
1718.3
1718.3
1718.4
1718.4
1718.3
1718.3
1718.4
1718.4
1718.3
1715.3
1715.3
1715.3
1715.2
7.7
1707.7
1717.3
1717.4
1717.3
1717.4
1714.9
1714.7
1715.0
1715.5
1715.6
1715.6
1715.6
1714.8
1714.6
1714.8
1714.6
1714.3
1714.2
1713.4
1713.6
1713.5
1713.4
1714.4
1714.6
1714.6
1714.6
1714.4
1714.4
1714.5
1714.5
1714.6
1714.6
1714.6
1714.6
1714.4
1714.6
1714.7
1714.7
1713.5
1714.9
1715.0
7.6
1717.5
1715.3
1715.2
1715.2
1715.2
1715.0
1715.0
1715.7
1715.6
1715.7
1715.7
1715.7
1715.7
1715.7
1715.6
1715.7
1715.7
1715.7
1715.7
1717.4
1714.7
1714.8
1717.5
1716.7
1716.7
1715.0
1715.10 1716.7
1716.7
1717.4
1717.4
1717.4
1717.3
1715.0
1713.4
1714.0
1714.0
1713.9
1713.7
1713.4
1714.3
1714.2
1714.2
1714.11
1713.5
1713.4
1714.8
1714.4
1714.2
1714.0
1713.9
1714.0
1714.5
1714.7
1714.2
1714.5
1714.6
1714.18
1714.2
1714.3
1714.6 0 1714.5
1714.4
1714.4
1714.2
1714.19
1714.3
1714.7
1713.5
1713.6
1714.2
1714.5
1713.8
1714.0
1713.5
1713.6
1712.6
1716.8
1716.8
1715.8
1715.8
1716.8
1716.8
1715.0
7.7
7.7
7.7
1713.4
1714.0
1714.0
1713.9
1713.8
1713.6
1714.3
1714.3
1714.2
1714.16
1714.0
1715.0
1713.9
1714.19
1714.7
1713.4
1713.5
1713.7
1715.0
1717.5
1717.5
1715.0
1714.8
1714.8
1714.7
1714.6
1714.5
1714.6
1715.13 1715.12
1715.11 1715.10
1715.14
1715.14
1715.11 1715.0
1715.0
1715.0
1715.12
1715.0
1717.5
1714.7
1714.8
1714.9
1716.7
1716.7
1716.7
1716.7
1714.8
1715.3 2 1715.3
1715.8
1715.8
1715.2
1715.0
1715.3
1716.8
1716.8
1715.0
1715.0
1717.4
1717.5
1716.7
1716.7
1714.9
1714.8
1714.4
1713.6
1713.8
1714.0
1714.0
1713.9
1714.0
1714.2
1714.2 0 1714.0
1714.12
1714.3
1714.7
1714.6
1714.6
1714.8
1714.7
1714.14
1712.8
1713.7
1713.8
1713.9
1713.6
1712.8
1712.17
1711.0
1714.5
1714.2
1713.8
1713.2
8.9
9.5
9.5
8.8
8.3
1713.0
1712.9
1714.4
1714.5
1714.4
1714.0
1713.6
1713.6
1714.8
1714.8
1714.6
1714.6
1714.8
1714.8
1714.0
1713.8
1713.8
1713.6
1714.2
1714.4
1714.4
1711.6
1710.15
1709.7
8.5
1709.10
1710.4
1710.2
9.8
1713.11
1712.6
8.8
1712.6
1712.3
8.3
8.3
1713.5
1714.2
1713.9
1713.2
1712.6
1711.8
1710.7
1714.0
1713.8
1713.3
1712.8
1713.4
1713.6
1713.5
1713.0
1712.3
1713.3
8.8
1709.6
1712.6
1712.4
1711.5
8.8
8.7
8.8
8.8
9.2
7.4
1706.9
6.2
1713.0
8.8
1713.0
1712.9
1713.2
1712.3
1713.0
1714.3
1714.3
1714.3
1714.2
1710.9
8.8
IP/
5/
8"
P K
P K
P K
P K
P K
P K
TRA
V130/
H T
TRA
V131/
H T
TRA
V132/
H T
TRA
V133/
M A G
TRA
V134/
H T
TRA
V135/
M A G
TRA
V136/
H T
TRA
V137/
H T
TRA
V140/
M A G
TRA
V141/
TA
C K
TRA
V142/
TA
C K
30"M A
GN
OLIA
B C
1 FWK
1+
B C
B C
B C 1 P
C
B C
B C
B C
B C
B C
B C 1 P
T B C 1-
B C 1+
B C
B C
B C
B C
B C 1 B C
B C 1 P
C
B C
BC
1-
PT
FW
K1 B
C 11+
PC
BC
B C 11 P
T
BC
BC
B C
B C
B C
B C
B C
PC
B C
B C
B C
PT
B C
BLD
B
LD
B
LD
TO
E
B
LD
B
LD
BLD
EC
B
LD
B
LD
BLD
EC
BLD
EC
B
LD B
LD
BLD
EC
BLD
EC
B
LD
B
LD
B
LD
B
LD
TOE
7 B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LDB
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
TOE
7 E
C B
ST
P
EC
B
STP
TO
E
BW
K
BW
K
GU
T1+
B
W K1-
BW
K 1+
7 EP
22+
7 FW
K1+
B W L+
7/ 12"
B W L/
B W L/
B W L-
7/ 12"
B W L+
7/ 12"
EC
BW
L/12"
B W L/
B W L-
7/ 12"
EP1
BW
L1+7/ 6"
EGR
V 1-
B
W L1/
6"
EP
1 BW
L2 7/
6"
EGR
V 1+
B
W L2
6"
CL
CL
CL
CL
CL
C L C
L1
CL
CL
CL
CL
C L-
C L1
C L C
L1
C
OL
C
OL T
OP
1-
C O L+
C O L-
C O L+
C O L-
C O L T
OP
C
OL
CO
L/12"X12
CO
L/12"X12
C O N
DS DS
DS
GUT1 EC
EP
EC
EC
EC
EP
BLD
EC
BLD
EC
BLD
EC
BLD
EC
BLD
EC
EC
EC
STEP
S TS
TP
TOE
7 E
C B
ST
P
EC EC
EC
B
STP
TO
E
EC
TS
TP-
EC
EC
EC
EC
EC
BW
L/12"
EC
TOE
7 E
C1
EC
EC
EC
1 PC
EC
EC
1 EC
PT
EC
GU
T2
PC
EC
EC
PC
EC
EC
EC
2 P
T
EC
GU
T
P T
EG
RV
EG
RV
EG
RV
EG
RV
EG
RV
EG
RV
EGR
V 1-
B
W L1/
6"
EGR
V 1+
B
W L2
6"
GU
T1 EP+
EP
EP
EP
EP
EP
EP
EC
EP
EP
EP
EP
EC
EP
EP
EP
GU
T1-
PT
EP
EP1
EP1
EP1
EP1
EP1
EP1
EP1
EP1
EP1
EP1
EP1
EP1
EP1
EP1
EP1
BW
L1+7/ 6"
EP1
FWL1+
EP
1 FWL2+
EP
1 BW
L2
7/
6"
EP1
EP
EP
EP
EP
EP
EP
BW
K 1+
7 EP
22+
7 FW
K1+
FE
FE/
GATE
FE/
GATE
FE
FE
FE
FE
FE
UG
W -7
FH
B C
1 FWK
1+
FW
K
FW
K
GU
T1-
F
W K1-
BW
K 1+
7 EP
22+
7 FW
K1+
FW
K
FW
K1 B
C 11+
PC
EP1
FWL1+
FW
L1 TS
TP
EP
1 FWL2+
FW
L2 TS
TP
GND
GND
GND
GND
GND
GND
GND
GUT1
GUT1
GUT1
SG
I
GUT1
GU
T1
P C
GUT1 EC
GUT1
GUT1
GUT1 GUT1
GUT1
GU
T1
P T
GU
T1-
F
W K1-
GU
T1+
B
W K1-
GUT1
GUT1
GU
T1 EP+
GUT1
GUT1
GUT1
GU
T1
P C
GUT1
GU
T1-
PT
EP
GUT11+7
PC
GU
T11
GU
T11 P
T
GU
T11
GU
T11 SG
I
GU
T11
GUT11-
GU
T2
GU
T2
GU
T2
GU
T2
GU
T2
PC
EC
GU
T2
GU
T2
EC
GU
T
P T
GU
T2
GU
T2
SG
I
GU
T2
PAV
PAV
PAV
PAV
PAV
PAV
PAV
PAV
PAV
PAV
PAV
PAV
PAV
RA
IL+
RA
IL-
RA
IL+
RA
IL-
RA
IL+
RA
IL-
GUT1
SG
I
GU
T2
SG
I
GU
T11 SG
I
SGN
SSB
X
SSM
H
STEP
S+
7/ M
ETA
L
STEPS N
E
EC
STEP
S TS
TP
STEP
S
UGS
TM
2 UG
S
TM
1-7
STM
M H
UG
S
TM
2 STM
M H
UG
S
TM
B
LD
TO
E
7TO
E
TO
E
TO
E
TO
E
TO
E
TOE
7 E
C1
TOE
TOE
7 E
C B
ST
P
EC
B
STP
TO
E
TOE
7 B
LD
TOE
TO
E
TOP
TO
P
C O L T
OP
TO
P 1+
TOP
C
OL T
OP
1-
EC
STEP
S TS
TP
EC
TS
TP-
FW
L1 TS
TP
FW
L2 TS
TP
UGC
W
UGC
W
UGC
W
UGC
W 1-
U
GC
W
U
GC
W
U
GC
W
UG
C W 2-
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UG
E1-
UG
S
TM
2 STM
M H
UG
S
TM
UGS
TM
UG
STM
1+
UGS
TM
UGS
TM
UGS
TM
UGS
TM
2 UG
S
TM
1-7
STM
M H
UG
S
TM
2+
UG
STM
UGS
TM
2 UG
S
TM
1-7
STM
M H
UG
STM
UG
STM
2UG
STM
UG
STM
UG
STM
UG
S
TM
2 STM
M H
UG
S
TM
UG
STM
UG
STM
UG
STM
UG
S
TM
2-
UG
W
1 UGW
UG
W W
V
UG
W -7
FH
UG
W
1 UGW
UG
W W
V
UG
W
UG
W
UG
W
UG
W
UGW
UGW
1+
UGW
UG
W
1 UGW
UGW
UGW
UGW
UGW
UG
W
1 UGW
UGW
1 W
V
UGW
UGW
UGW
UGW
UGW
1-
UG
W W
V
UG
W W
V
UGW
1 W
V
B C
B C
B C
B C
B C 2+
7 P C
B C
B C
B C
B C
B
LDB
LD
B
LD
B
LD
B
LD
EC
1-
7 B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD
B
LD-
7 C
LO
TO
E1 BS
TP+
B
STP
B
STP
TO
E1 BS
TP-
FW
L B
STP
B S
TP-
B W L+
7/ 12"
B W L-
7/ 12"
B W L+
7/ 12"
B W L-
7/ 12"
B W L+
7/ 12"
B W L/
B W L/
B W L/
B W L-
7/ 12"
B W L+
7/ 12"
B W L/
B W L/
EP
7 B
W L/12"
B W L-
7/ 12"
TOE
7 B
WL3
8"
EP
BW
L3/
B W L3
7/
CC
CC
CC
CC
7 C
LO
C L1
C L1 C L1
C L1
C L1
C L1
C L1
C L1 C L1
C L1
UG
W 1 C
L1
C L1
C L1
C L1
C L1
C L1-
C
OL/
2X2
CO
L/12"X12
CO
L/12"X12
DR
N /12
DS
TOE
1 E
C
EC
ECEC
EC
EC
TS
TP+
FW
L+
EC
7 EC
EC
EC
EC
7 EC
EC
EC
EC
7 EC
EC
EC
EC
TSTP
EC
TOE
EC
TOE
EC
TS
TP-
EC
EC
TSTP
EC
TSTP
EC
EC
ECEC
EC
EC
1-
7 B
LD
EC
1+
EP2
7 GUT
1+
PC
EC
1+
EC
1 PC
EC
EC
PT
EC
2+
EP2
GUT2
PC
EC
PC
EC
EC
2 P
T
EG
RV
EG
RV
EM
H
EM
P
TY
EP1
EP1
EP2
7 GUT
1+
PC
EC
1+
EP
2 EP
EP
EP
EP
EP
EP
EP
EP
EP2
GUT2
EP
7 B
W L/12"
EP
EP
EP
EP
EP
EP
BW
L3/
FDC
FE
FE
2+
FE2 FE
2/
G
ATE
FE
2/
G
ATE
FE2
FE2
FE2
FH
FW
L+
FW
L TSTP+
TOE
1-
7 FW
L-
TOE
1+
7 FW
L+
FW
L TSTP-
FW
L-
EC
TS
TP+
FW
L+
FW
L B
STP
FW
L
FW
L-
GND
EP2
7 GUT
1+
PC
EC
1+
GUT1
GUT1
GUT1
GUT1
EP2
GUT2
GU
T2
GU
T2
GU
T2
GU
T2
PAV
PAV
PAV
PAV
SG
N /2.5
SG
N /2.5
SGN
STEP
S+
7/ M
ETA
L
STEPS N
E
STEP
S
STEP
S
TOE
TO
E T
OE1+
TO
E
TO
E
TO
E
TO
E
TOE
7 B
WL3
8"
TOE
7 TO
E
TO
E
TOE
TOE
TO
E
TO
E
TOE
TOE
7 TO
E
TOE
TOE
TOE
EC
TOE
EC
TOE
TOE
TOE
7 TO
ETO
E
TOE
TO
E T
OE1+
TOE
1 E
C
TO
E1 BS
TP+
7 TOE
1-
7 FW
L-
TOE
1+
7 FW
L+
TO
E1 BS
TP-
TOE
TOE
1-
FW
L TSTP+
FW
L TSTP-
EC
TS
TP+
FW
L+
TS
TP-
EC
TSTP
EC
TS
TP-
EC
TSTP
EC
TSTP
UGE
5+
UG
E
UG
E
UG
E
W V U
G W
UG
W
1 UGW
UGW
1+
UGW
UG
W
1 UGW
UGW
UGW
UGW
UGW
UGW
UGW
1 U
G W 2+
UG
W 1 C
L1
UGW
UG
W 1-
UGW
1 U
G W 2+
UGW
W V
W V
W V U
G W
B C
B C
B C
B C 1 P
T
B C
B C
B C
B C
B C
B
OL
B
OL
B
OL
B
OL
C B /2
X2
CC
7CC
DEC
K
DEC
K
DEC
K
DEC
K
EC
1-
EC
EC
1+
EC
EC
EC
EC
EC
1-
EC
GU
T
EG
RV
EG
RV
EG
RV
EG
R V1-
EP1-
7 E
P2-
EP1-
7 E
P2-
FE2 FE2
FE2 FE2
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GUT1
GUT1
GU
T1
P T
GUT1
EC
GU
T
GU
T2
GU
T2
GU
T2
O H G
OH
G
OH
G
OH
G C
LO
PAV
PAV
UG
W 2-
7 P
IV
STM
H
TOE
TO
E
TOE
TO
E
TO
E
TO
E
TO
E
TOE
TOE
TOE
TOE
1-
TRA
N S/
X5
UGE
3-
U
GE1-
UG
E
UGE
3-
U
GE1-
UG
E
UG
E
UG
E
UGE
5-
UGS
S 1-
UGT+
UG
T
UG
T
UG
T
UG
T
UG
W 2-
7 P
IV
1 1362
1316 1318
14881489
1380 138
1327 1333
1378 1380
1218 1219
1285 1286
1287 1385
12321233
926 927
936 937
864865
868869
873876
A
18111812
19891990
1817 1818
1889 1890
1 1902
1962 1965
1967178
A
1876 1877
18521853
1888 189
1899 1900
1927 1928
1805 1806
5 233
H
Y D
SM
H
W V
W V
W V
H Y
D W V
W V
W V
C .O
P
IV
WATER HYDRANT
#2-8
WATER HYDRANT
#2-9
POST INDICATOR
VALVE
W W W W
W
W
W W
SAN
SAN
SAN
STM
3" DOMESTIC WATER
SERVICE ENTRANCE
EXISTING 6" SAN
EXISTING 6" SAN
2'x2' CB Rim=1708.39 Inv.=1704.73
STM MH.
Rim=1709.61 Inv.=1703.13(S) Inv.=1700.34
S T
M
4" (86 GPM)
INV.: 1710.76
8" STORM
F201
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:0
P M
PS100
PLUMBING SITE PLAN
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:0
P M
PS100
PLUMBING SITE PLAN
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
1/8" = 1'-0"
SITE PLAN
PLAN NOTES
1. EXISTING PIPING TO REMAIN.
2. NEW 8" STORM PIPING. PROVIDE ADAPTER AND CONNECT TO STUB. REFER TO CIVIL DRAWINGS AND PP101 FOR CONTINUATION.
SHEET NOTES
A. REFER TO SHEET P001 FOR ABBREVIATIONS, LEGEND & GENERAL NOTES.
B. BELOW GRADE/ UNEXCAVATED SPACE SANITARY PIPING TO BE JETTED AND VISUALLY INSPECTED TO CLEAR
AND IDENTIFY COMPROMISED PIPING. REPORT FINDINGS TO COR.
BFPBFP
6"
S A
N
S A
N
6"
SP
UP4" SAN5
2" VR
P-106
P-414
P-604
CO
P-106
FD-C
P-202
2" VR
FD-C
P-105
2" VR
2" VR
P-106
P-106
2" VR
P-414
P-604
S A
N
P-528
P-608
P-502
P-528
P-106
2" VR
P-106
UP4" SAN
P-414(2)
P-528
ELECTRICAL
ROOM
MECH/ELEC ROOM
MECH/ELEC ROOM
FD-E
FD-E
SAN
S A
N
DWH
P-418
CO
UP4" STM
UP4" STM
S T
M
S T
M
4"
INV.: 1710.75
S A
N
SAN
SAN
IT CLOSET
003A
2" VR
2" VR
2" VR
2" VR
S A
N
4" (86 GPM)
4" (86 GPM)
FD-1
FD-1
BELOW FLOOR ACCESS
FD-C
HT
LD
2" VR
3" HD
4 15
UNEXCAVATEDUNEXCAVATED
P-418
2" VR
CO
OPEN WOODEN SUPPORT STRUCTURE
EMERG ELEC ROOM
CO
CO
MECH/ELEC
ROOM
MECH/ELEC
ROOM
ELECTRICAL
ROOM
MECH/ELEC
ROOM
DWH
0.75"
UP0.5"
0.75"
1.25"
1.25"
1.5"1.25"
1.25"
1.25"
1.25"
1.25"
UP0.75" DHWR
UP0.75" DHW
UP0.5" DCW
A
P601
UP0.75"
UP0.5"
UP1"
TYP.
TYP.
UP0.75" DHW
UP1" DCW
UP0.5"
1.25"
1"
0.5"
0.75"
0.75"
0.75" 1.25"
UP0.5"
UP1"
UP0.75"
W S
IT CLOSET
003A
R R
BELOW FLOOR ACCESS
W S
TP
UP0.5"
UNEXCAVATEDUNEXCAVATED
UP0.5" DCW
UP1" DHW
UP0.75" DHW
OPEN WOODEN SUPPORT STRUCTURE
EMERG ELEC ROOM
SHEET NOTES
A. REFER TO SHEET P001 FOR ABBREVIATIONS, LEGEND & GENERAL PROJECT NOTES.
B. LABEL ALL PIPING PER SPECIFICATION 22 05 11 SECTION 1.3.B ASME A13.1 SCHEME FOR IDENTIFICATION OF PIPING SYSTEMS.
C. REFER TO MECHANICAL/ ELECTRICAL DRAWINGS FOR ASSOCIATED EQUIPMENT.
D. RECONNECT NON-POTABLE WATER PIPING & BACKFLOW PREVENTERS SERVING MECHANICAL EQUIPMENT.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:0
:3
P M
PP101
FOUNDATION AND BASEMENT
NEW WORK PLANS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:0
:3
P M
PP101
FOUNDATION AND BASEMENT
NEW WORK PLANS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
PLAN
NORTH
PLAN NOTES
1. EXISTING TO REMAIN.
2. SANITARY PIPING LOCATED BELOW FLOOR SLAB.
3. PIPING CAPPED BELOW GRADE.
4. PROVIDE STAINLESS STEEL DRAIN PAN BELOW DRAINAGE PIPING. RUN 1" DRAIN TO ADJACENT 3" HUB DRAIN IN ROOM 003.
PROVIDE HARD-WIRED WATER DETECTION SENSOR. BASIS OF DESIGN: RDT WATER ALARM SYSTEM #RS-096, 120V-1PH OR EQUAL. MOUNT CONTROLLER ON WALL NEAR WATER HEATER. COORDINATE FINAL LOCATION WITH COR AND DIVISION 26.
CONNECT ALARMS TO BUILDING AUTOMATION SYSTEM.
5. PROVIDE FREEZE PROTECTION ON ALL DOMESTIC WATER PIPING AND SANITARY TRAPS IN BELOW FLOOR SPACE.
EXTEND MIN. 12" INTO WARM SPACE AND TERMINATE. MOUNT HEAT TRACE CONTROLLER ON WALL NEAR WATER HEATER.
BASIS OF DESIGN: RAYCHEM #C910-485, 3XLE1, (1-30A, 2-20A CIRCUITS) 2KW, 120V-1PH OR EQUAL.
COORDINATE FINAL LOCATION WITH COR AND DIVISION 26. CONNECT ALARMS TO BUILDING AUTOMATION SYSTEM.
6. PROVIDE NEW RPZ TYP BACK FLOW PREVENTERS, PRESSURE REDUCING VALVES ARRANGEMENT AND ASSOCIATED PIPING AND
PIPELINE DEVICES. REFER TO DETAIL A/ P601.
7. PROVIDE NEW MIXING VALVE, DHW RECIRC PUMP AND EXPANSION TANK. REFER TO SCHEDULES AND DETAIL A/ P601.
8. FOLLOW ROUTING OF EXISTING DCW PIPING TO FIXTURES IN THE FIRST FLOOR LOBBY. COORDINATE ROUTING WITH
DIVISION 23.
9. AREA IS HEAVILY CONGESTED. COORDINATE NEW WORK CLOSELY WITH DIVISION 23.
10. PIPING CONTINUED ON CIVIL PLANS.
11. SAW CUT AND TRENCH EXISTING FLOOR SLAB TO ACCOMMODATE NEW SANITARY PIPING. PROVIDE BEDDING, BACKFILL AND COMPACTION PER SPECIFICATIONS. PATCH CONCRETE TO FLUSH WITH EXISTING FLOOR SLAB AND RE-SURFACE TO MATCH
ADJACENT FLOOR.
12. TRAP PRIMER TO SERVE HUB DRAIN. REFERENCE PLAN NOTE 17 AND DETAIL J/ P601.
13. NO PIPING SHALL BE INSTALLED ABOVE THIS ROOM. KEEP DOOR OPENING CLEAR OF OBSTRUCTIONS.
14. NO PIPING SHALL BE LOCATED DIRECTLY ABOVE ELECTRICAL EQUIPMENT.
15. PROVIDE HARD-WIRED WATER DETECTION SENSOR ON FLOOR NEAR DOOR. REFERENCE NOTE 4 FOR CONTROLLER
INFORMATION.
16. PROVIDE ADAPTER AND CONNECT TO STUB. REFER TO CIVIL DRAWINGS FOR CONTINUATION.
17. CONNECT TO EXISTING 2" SANITARY AND EXTEND SANITARY PIPING ALONG WALL. PROVIDE 3" HUB DRAIN.
18. SANITARY DRAIN AND DISTRIBUTION PIPING ROUTED IN CASEWORK.
1/8" = 1'-0"
BASEMENT PLAN - DRAINAGE
1/8" = 1'-0"
BASEMENT PLAN - DISTRIBUTION
E. REFER TO DRAINAGE/ DISTRIBUTION ISOMETRICS, SHEETS P901 AND P902 FOR ADDITIONAL INFORMATION.
P-106L
P-202
P-106L
P-414
P-414
P-528
LOBBY
MEN'S
WOMEN'S
STORAGE
CORRIDOR 106
TOILET
TOILET
DRESSING
ROOM
AUDITORIUM
STAGE
P-106
P-106
P-414(2)
111A
TOILET
FD-C
FD-C
V
V
P-418
P-608
P-106R
P-418
UP0.5"
CO
UP0.5"
DN0.75"
UP0.75"
P-528
UP2" V
P-604
P-604
P-801
DN0.75" DHWR
AP
P-502
P-528
DN0.5"UP0.5"
P-528
0.5"
DN1.5" SAN
DN0.5"
P401
P401
P-106R
P-106L
UP1.5" V
V UP
0.75"
AP
P-106L
P-414
P-414
P-106R
AP
JANITOR
DRESSING
ROOMAP
AP
P401
I
P601
I
P601
4" (43 GPM)
UP & DN4" STM
UP & DN4" STM
CO
CO
MECHANICAL
110B
TOILET
110A
MECHANICAL
111B
2" VR
SC1
SC1
FD-1
FD-1
4" (43 GPM)
UP4" OD
STAIRS REMOVED
FOR CLARITY
STAIRS REMOVED
FOR CLARITY
FD-C
DN0.75"
O D
UP4" OD
3" VR
P-528
P-414
P-414
P-528
DRESSING
ROOM
TOILET
TOILET
DRESSING
ROOM
V
1.5" VR
0.75" P-106R
P-106L
AP
RD1
4" (43 GPM)
4" (43 GPM)
OD1
RD1
OD1
4" (43 GPM)
VTR
VTR
CORRIDOR
4" (43 GPM) 5
AP
3" VR
O D
VS
T
M
SHEET NOTES
A. REFER TO SHEET P001 FOR ABBREVIATIONS, LEGEND & GENERAL PROJECT NOTES.
B. LABEL ALL PIPING PER SPECIFICATION 22 05 11 SECTION 1.3.B ASME A13.1 SCHEME FOR IDENTIFICATION OF PIPING SYSTEMS.
C. REFER TO MECHANICAL/ ELECTRICAL DRAWINGS FOR ASSOCIATED EQUIPMENT.
D. RECONNECT NON-POTABLE WATER PIPING & BACKFLOW PREVENTERS SERVING MECHANICAL EQUIPMENT.
DCW
FIBERGLASS. COORDINATE WITH BATT INSULATION.
S L O
P E
S L O
P E
SLOPE
S L O
P E
S L O
P E
SLOPE OD1
OD1
RD1
3"VTR
3"VTR
EXISTING ROOF
HATCH
ERV
ERV
EF
RD1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:0
P M
PP102
FIRST AND SECOND FLOOR NEW
WORK PLANS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:0
P M
PP102
FIRST AND SECOND FLOOR NEW
WORK PLANS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
PLAN NOTES
1. BELOW FLOOR ACCESS.
2. HARD CEILING IN THIS LOCATION (GYPSUM BOARD/ PLASTER/ WOOD). REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL
INFORMATION.
3. PROVIDE ISOLATION VIBRATION INSULATION FOR TOILET ROOMS 110 AND 111 IN WALLS SHARED WITH THE AUDITORIUM. REFER
TO DETAILS A & B THIS SHEET.
4. INTERCEPT AND CONNECT TO EXISTING VENT STACK.
5. ROUTE PIPING EXPOSED TIGHT TO CEILING. COORDINATE WITH LIGHT FIXTURES.
6. EXISTING ROOF SCUPPER TO REMAIN. CLEAR OF ALL DEBRIS.
7. COORDINATE FLOOR DRAIN LOCATION WITH DIVISION 23. REFER TO MECHANICAL DRAWING FOR EQUIPMENT.
1/8" = 1'-0"
FIRST FLOOR PLAN
1/8" = 1'-0"
SECOND FLOOR PLAN
NTS
A
PARTITION VIBRATION ISOLATION
NTS
B
PIPE VIBRATION ISOLATION INSULATION
1/8" = 1'-0"
BACK ROOF PLAN
P-106R
P-414
P-604
AP
V
V UP
WOMEN'S
MECHANICAL
111B
P-106R
P-106L
FD-C
AP
P-418
V
V
V TOILET ROOM
111A
LOBBY
STAIRS NOT SHOWN FOR CLARITY
2" VR
2" VR
2" VR
DN0.75" DCW
DN0.5" DHW
0.75"0.5"
0.5"
0.75"
0.5"
FD-1
B
PP102
P-106R
DN3" SAN UP2" V
P-106L
P-414
P-414
AP
TOILET
TOILET
UP0.75" DCW
UP0.5" DHW
DN0.75" DHW
P-106
P-106
P-414(2) 0.5"
2" VR
P-801
CO
P-106L
P-414
P-604
P-106L
P-202
FD-C
2" VR
AP
P-418
MECHANICAL
110B
MEN'S
TOILET ROOM
110A
AP
STAIR NOT SHOWN FOR CLARITY
V
V
V
V
EXISTING VENT
RISER
0.75"
1"0.5"
2" VR
CRAWL SPACE
ACCESS
LOBBY
DN1" DCW
DN0.5" DHW
0.75"
0.5"
DN0.5" DHW
DN1" DCW
2" VR
FD-1
B
PP102
SHEET NOTES
A. REFER TO SHEET P001 FOR ABBREVIATIONS, LEGEND & GENERAL PROJECT NOTES.
B. LABEL ALL PIPING PER SPECIFICATION 22 05 11 SECTION 1.3.B ASME A13.1 SCHEME FOR IDENTIFICATION OF PIPING SYSTEMS.
C. REFER TO MECHANICAL/ ELECTRICAL DRAWINGS FOR ASSOCIATED EQUIPMENT.
D. RECONNECT NON-POTABLE WATER PIPING & BACKFLOW PREVENTERS SERVING MECHANICAL EQUIPMENT.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:1
P M
P401
ENLARGED PLANS
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
1/2" = 1'-0"
TOILET ROOMS - WOMENS 111 & 111A
1/2" = 1'-0"
BACK OF HOUSE BACK-TO-BACK TOILET ROOMS - TYPICAL
1/2" = 1'-0"
TOILET ROOMS - MEN'S 110 & 110A
PLAN
NORTH
1. COORDINATE FLOOR DRAIN LOCATION WITH DIVISION 23.
2. REFER TO P902 FOR DOMESTIC WATER ISOMETRIC FOR ADDITIONAL INFORMATION.
3. MECHANICAL ROOM ACCESS.
PLAN NOTES
OFFSET WASTE
TRAP PARALLEL
TO WALL
FINISHED FLOOR
ESCUTCHEON
LOOSE KEY
/STOP
TEMPERATURE
LIMITING DEVICE
FAUCET: REFER TO SPECIFICATIONS. NON-AERATED FLOW CONTROL DEVICE.
SINK: SOLID SURFACE WITH INTEGRAL BOWL.
TEMPERATURE
LIMITING DEVICE
OFFSET WASTE
TRAP PARALLEL
TO WALL
PROVIDE LAV SHIELD
ENCLOSURE.
LOOSE KEY STOP
ESCUTCHEON
FINISHED FLOOR
FAUCET: REFER TO SPECIFICATIONS. NON-AERATED FLOW CONTROL DEVICE.
LAVATORY: WALL HUNG.
CONCRETE FILL
TILE FLOOR
CEMENT BED
LOOSE GRAVEL AT
WEEP HOLES 3mm TO 6mm SIZE
NICKEL BRONZE
ADJUSTABLE STRAINER
(FLUSH WITH FINISHED
FLOOR)
CLAMP WATERPROOF
MEMBRANE INSIDE OF
DRAIN BODY
WATERPROOF
MEMBRANE
STRUCTURAL SLAB
FLASHING CLAMP WITH
WEEP HOLES
THREADED, CAULKED
OR NO-HUB
CONNECTION
PROVIDE A METAL SUPPORT
PLATE WHEN DRAIN IS
INSTALLED IN AN EXISTING
FLOOR - CAULK AROUND DRAIN
PRIOR TO RE-GROUTING
NOTE:
SLOPE MEMBRANE LINER 2% TO DRAIN.
[1 m m
1" [2
5m m
[1 m m
INSULATE
PIPE OR DUCT
PIPE SLEEVE
WHERE SPECIFIED
FLOOR
WELD
1/4" [6.4mm]
ANCHOR ROD FOR
NEW CONSTRUCTION
FIRESTOP MATERIAL
3/4" [19mm]
APPROVED FIRESTOP
INSULATION WITH
VAPOR BARRIER
3/4" [19mm] APPROVED
FIRESTOP INSULATION WITH
VAPOR BARRIER 6"
[150mm]
MASONRY
PARTITION INSULATED
PIPE OR
DUCT
6" [150mm]
FIRESTOP
MATERIAL
DRYWALL PARTITION
PARTITION SUPPORT
FLOOR OR DECK PENETRATION
6" [150mm]
6" [150mm]
PARTITION OR CHASE PENETRATION
NOTE:
1. APPLICABLE TO PENETRATIONS OF ALL FIRE RATED MEMBRANES,IN ACCORDANCE WITH NFPA 101.
REFER TO SPECIFICATIONS SECTION 07 84 00, FIRE STOPPING SYSTEMS.
2. REFER TO ARCHITECTURAL DRAWINGS FOR RATED WALLS.
OFFSET WASTE
TRAP PARALLEL
TO WALL
FINISHED FLOOR
ESCUTCHEON
LOOSE KEY
/STOP
TEMPERATURE
LIMITING DEVICE
FAUCET: REFER TO SPECIFICATIONS. NON-AERATED FLOW CONTROL DEVICE.
SINK: SOLID SURFACE WITH INTEGRAL BOWL.
PROVIDE COVER FOR EXPOSED
HANGER ROD
INSULATION (VAPOR
BARRIER TYPE IS
REQUIRED FOR LOW
TEMPERATURE PIPE)
PROVIDE HIGH COMPRESSIVE
STRENGTH INSULATION (9 PSF MIN.
DENSITY) UNDER INSULATION SHIELD
INSULATION SHIELD
AT HANGER
WELD
SADDLE
ADJUSTABLE CLEVIS HANGER TYPE 1 -
SEE SPECIFICATIONS
ADJUSTABLE CLEVIS HANGER TYPE 43 -
SEE SPECIFICATIONS
PROVIDE INSULATION SHIELD
& INSERT FOR ALL PIPING
(200mm [8"] MIN.)
15mm [½"] DIA.
HANGER RODS WITH
900mm [36"] MAX.
SPACING ON EACH
CHANNEL
BAND
43mm [1-⅝"] 12 GAUGE CHANNEL OR 50x50x6.4mm [2"x2"x¼"] ANGLE m m [1
M
A X
SIDE VIEW TRAPEZE HANGER FOR UP TO
453KG [1000lb.] UNIFORM LOAD
[1]
[1¼]
THRU 20
[THRU ¾]
[1½]
[2½]
[2]
[3]
[4]
[5]
[6]
[10]
[10]
[12]
[14]
[16]
[18]
[20]
[24]NOM. SIZE
[7]
[7]
[7]
[9]
[11]
[10]
[12]
[14]
[16]
[17]
[19]
[22]
[23]
[25]
[27]
[28]
[30]
[32]PIPE
[6]
[7]
[5]
[8]
[9]
[8]
[10]
[12]
[13]
[14]
[16]
-TUBING
mm
[IN]
mm
[FT]
mm
[FT]
NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.
MAXIMUM PIPE/TUBING SUPPORT SPACING
NOTE:
SEE SPECIFER FOR DETAILED HANGER REQUIREMENTS
EXTERIOR WALL SYSTEM
THREADED
GALVANIZED
PIPE
NICKEL BRONZE WITH
STAINLESS STEEL SCREEN
CAULK UNDER AND AROUND
SCUPPER DRAIN PRIOR TO
INSTALLATION
OVERFLOW
STORM PIPE
WITH INSULATION
EXTRA HEAVY DUTY
NO-HUB COUPLING
NOTE: COORDINATE EXACT LOCATIONS AND
ELEVATIONS WITH ARCHITECT.
1. AIR GAP OVER FLOOR DRAIN
2. NEW COMBINATION TEMPERATURE-PRESSURE RELIEF VALVE.
3. NEW VACUUM RELIEF VALVE.
4. RECIRCULATION PUMP CONTROL AQUASTAT.
5. AIR GAP OVER FLOOR.
6. EXISTING WATER HEATER. FLUSH WATER HEATER PER MANUFACTURE'S INSTRUCTIONS. PROVIDE DRAIN PAN.
7. MINIMUM 27" HEAT TRAP.
8. EXISTING PIPING.
9. NEW FLOW THROUGH EXPANSION TANK.
10. NEW THERMOSTATIC MIXING VALVE.
11. NEW RECIRC PUMP.
12. AIR GAP BFP DRAINS OVER SUMP PUMP.
2 EXT
RCP
DWH
T
PT
T
NOTES
P/T
1.25"0.75"
T
T
TMV
FROM BUILDING
TO BUILDING
1.25"
FROM WATER SERVICE ENTRANCE
P P
3"
TO
BUILDING
FIXTURES
BFP
8 8
3"
3"
2.5"TYP
1.5"TYP1.5"TYP
2.5"TYP
3"
3"
BFP
P P
TO MECHANICAL
EQUIPMENT
1.5"TYP1.5"TYP
2.5" 2.5"
TO MECHANICAL
EQUIPMENT
2"
2 9/16"
MIN. W / COVER
(COVER NOT SHOWN)
1" MAX.
8 3/8" [ 213 ]
5" x 5"
2 9/16"
MIN.
TRAP PRIMER, WITH DISTRIBUTION
UNIT WHEN SERVING MULTIPLE
DRAINS.
0.5''
SUPPLY SHALL BE
OFF TOP OF MAIN
COLD WATER MAIN
T P
TP
WALL
HUB DRAIN
FLOOR
TP
INSTALL PIPING TIGHT TO WALL
SURFACE IN UNFINISHED AREAS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:1
P M
P601
DETAILS AND SCHEDULES
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
FIXTURE SCHEDULE
MARK Count
MOUNTING
HEIGHT DESCRIPTION
FLOW WASTE & VENT SUPPLY FIXTURE UNITS WRIST
BLADE
HANDLES SENSOR REMARKSGPM GPF
OUTLET VENT COLD HOT TEPID
DRAINS
WATER
IN MM IN MM IN MM IN MM IN MM COLD HOT
P-106L 5 FS, NOTE 4 WATER CLOSET/ TANK/ ADA - 1.28 3 76.2 2 50.8 0.5 12.7 3 2.2 0 N/A LEFT HAND TRIP LEVER
P-106R 4 FS, NOTE 4 WATER CLOSET/ TANK/ ADA - 1.28 3 76.2 2 50.8 0.5 12.7 3 2.2 0 N/A RIGHT HAND TRIP LEVER
P-202 1 NOTE 1 URINAL/ ADA - 0.5 2 50.8 2 50.8 0.75 19.05 2 5 0 NO FLUSH VALVE: MANUAL
P-414 6 NOTES 1, 3
& 5
LAVATORY/ WH/ ADA 0.5 - 1.25 31.75 1.5 38.1 0.5 12.7 0.5 12.7 2 1 1 N/A NO FAUCET: STANDARD SPOUT/ SINGLE LEVER/
TEMPERATURE LIMITING DEVICE
P-418 2 NOTES 3 & 5 LAVATORY/ SOLID SURFACE WITH INTEGRAL BOWL 0.5 - 1.25 31.75 1.5 38.1 0.5 12.7 0.5 12.7 2 1 1 N/A NO FAUCET: STANDARD SPOUT/ SINGLE LEVER/
TEMPERATURE LIMITING DEVICE
P-502 1 FS SERVICE SINK/ FLOOR SET/ CORNER 28"x28"x12" 2.5 - 3 76.2 0.5 12.7 0.5 12.7 3 2.25 2.25 N/A NO FAUCET: PAIL HOOK/ VACUUM BREAKER/ CROSS
HANDLES/ INTEGRAL CHECK STOPS/ HOSE
P-528 4 NOTES 3 & 5 SINK/ SOLID SURFACE WITH INTEGRAL BOWL 0.5 - 1.5 38.1 1.5 38.1 0.5 12.7 0.5 12.7 2 2.5 2.5 YES FAUCET: GOOSENECK SPOUT/ WRIST BLADES/
TEMPERATURE LIMITING DEVICE
P-604 2 SET
BUBBLER AT
36" AFF
ELECTRIC WATER COOLER/ RECESSED/ BOTTLE FILLER/ ADA 1.25 31.75 0.375 9.525 0.5 0.5 0 PROVIDE FILTER 51300C
P-608 1 SET
BUBBLER AT
36" AFF
ELECTRIC WATER COOLER/ WALL MOUNTED/ BOTTLE FILLER/ ADA - - 1.25 31.75 1.5 38.1 0.5 12.7 0.5 0.5 0 PROVIDE FILTER 51300C
P-801 1 EXISTING
LOCATION
WALL HYDRANT/ EXTERIOR/ FREEZE PROOF 0.75 19.05 0 3 0
DRAIN SCHEDULE
SYMBOL Count DESCRIPTION
BODY STRAINER / GRATE TOP FINISH
C.I. S.S. C.R. BRASS ADJUST. FLAT RECESS DOME
NICKLE
BRONZE C.I. C.R. S.S.
FD-1 2 2" MEDIUM DUTY/ TYPE S/ DECK PLATE ● ● ●
FD-C 3 3" MEDIUM DUTY/ VANDAL RESISTANT/ TYPE C ● ● ●
FD-E 2 4" MEDIUM DUTY/ VANDAL RESISTANT/ TYPE -E ● ● ●
OD1 2 4" FLANGED WITH ADJUSTABLE DRAINAGE COLLAR/ SUMP RECIEVER/ BEARING PAN/ DECK CLAMP/DOME STAINER ● ● ● ●
RD1 2 4" FLANGED WITH ADJUSTABLE DRAINAGE COLLAR/ SUMP RECIEVER/ BEARING PAN/ DECK CLAMP/DOME STAINER ● ● ● ●
SC1 2 SCUPPER WITH REMOVEABLE SCREEN (NO HUB) ●
FIXTURE SCHEDULE NOTES:
1. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS FOR EXACT LOCATION AND MOUNTING HEIGHT
2. SUPPLY SIZES ARE FIXTURE CONNECTION SIZES. DOMESTIC COLD WATER SUPPLY SIZES SERVING FLUSH VALVES SHALL BE MINIMUM ONE PIPE SIZE LARGER THAN THE INDICATED CONNECTION SIZE, OR SIZES AS SHOWN ON THE FLOOR PLANS.
3. PROVIDE NON-AERATED FLOW CONTROL DEVICE ON LAVATORY AND SINK FAUCETS. DO NOT USE AERATORS.
4. INSTALL TRIP LEVER ON WIDE SIDE OF STALL PER ADA GUIDELINES.
5. TEMPERATURE LIMITING DEVICE SHALL BE UNDERCOUNTER ASSE 1070 COMPLIANT THERMOSTATIC MIXING VALVE.
DRAIN SCHEDULE NOTES:
1. PROVIDE TRAP SEAL/ GUARD FOR FD-1, FD-C & FD-E DRAINS. TRAP GUARD TO BE ASSE 1072 APPROVED.
2 PROVIDE THREADED PLUG FOR ALL TRAP PRIMER CONNECTIONS NOT USED.
NTS
C
P-418 LAVATORY/ SOLID SURFACE WITH INTEGRAL BOWL
NTS
B
P-414 LAVATORY/ WALL HUNG
NTS
E
FD-C TYPE "C" FLOOR DRAIN
NTS
G
PIPE/ DUCT PENETRATION OF SMOKE/ FIRE BARRIERS
NTS
D
P-528 SINK/ SOLID SURFACE WITH INTEGRAL BOWL
NTS
H
PIPE HANGERS
EXPANSION TANKS
MARK DESCRIPTION
BASIS OF DESIGN
A S
M E
R A
T E
D
VOLUME
B L A
D D
E R
D
IA
P H
R A
G M
F L O
W T
H R
O U
G H
CONNECTION
SIZE(S)
APPROX.
DIMENSIONS
CONCRETE
PAD
SEISMIC
RESTRAINTS
SEE NOTEMANUFACTURER MODEL T
O
T A
L
A C
C E
P T
A N
C E
WIDTH /
DIAMETER L
E N
G T
H
H E
IG
H
T
R E
Q U
IR
E
D
IMPORTANCE
FACTOR
EXT EXPANSION TANK/ FLOW-THROUGH WESSELS COMPANY TTA-5-Rx-FF ● 3.5 2.5 - - ● 0.75" 10" 14" - - -
PUMPS
MARK DESCRIPTION
BASIS OF DESIGN TYPE
C A
P A
C
IT
Y
P R
E S
S U
R E
H E
A D
INPUT
V O
L T
A G
E
P H
A S
E
FLUID
CONNECTIONS
APPROX.
DIMENSIONS
C O
N C
R E
T E
P A
D
SEISMIC
RESTRAINTS
S E
E N
O T
E
MANUFACTURER MODEL B
O
O S
T E
R
R E
C
IR
C U
L A
T
IO
N
S E
W A
G E
E J E
C T
O R
S U
M P
F U
E L
W A
T T
S
Q
T Y
H
P
I N
O U
T
W
ID
T H
D
IA
M
E T
E R
L E
N G
T H
H E
IG
H
T
R E
Q U
IR
E
D
I M
P O
R T
A N
C E
F A
C T
O R
RCP DOMESTIC HOT WATER RETURN PUMP/ AQUASTAT BELL & GOSSETT PL-30 - ● - - - 2.5 GPM
18 FT HD
12 1/12 120V-1
PH
0.75" 0.75" 4.5" 9" 6" - - -
WATER TEMPERATURE MIXING VALVES
MARK DESCRIPTION
BASIS OF DESIGN TYPE
V O
L T
A G
E
P H
A S
E
R A
T E
D F
L O
W A
T
P
S
ID
U
T L
E T
T E
M P
E R
A T
U R
E
°F
A S
S O
C
IA
T E
P U
M P
T A
G
CONNECTIONS
APPROX.
DIMENSIONS
SEISMIC
RESTRAINTS
S E
E N
O T
E
MANUFACTURER MODEL M
A
N U
A L
E L
E C
T R
IC
D C
W
D H
W
T E
M P
E R
E D
D H
W R
R
W
ID
T H
D
IA
M
E T
E R
L E
N G
T H
H E
IG
H
T
R E
Q U
IR
E
D
I M
P O
R T
A N
C E
F A
C T
R
TMV THERMOSTATIC MIXING VALVE WATTS LFMMVM1-UT ● - - 5 GPM 135 - 0.75" 0.75" 1.25" 0.75" - 8.563" 3.313" 6.688" - -
NTS
I
SECONDARY ROOF DRAIN SCUPPER
NTS
A
DOMESTIC WATER HEATER - SCHEMATIC
NTS
F
FD-1 FLOOR DRAIN
EQUIPMENT NOTES:
1. PROVIDE BASIS OF DESIGN OR EQUAL.
NTS
J
TRAP PRIMER
add hose bibb
P-604
P-414
P-106L
2"
2"
2"
3" 2"1.5"
CO
3"
2"
P-418
P-106L 2"
P-202
FD-C
2"
1ST FLR
2"
3" 3"
3" 3"
2"
1ST FLR
3"
3"
3" P-106R
FD-C
P-106L
P-418 2"
2"
3"
3"
1ST FLR P-106R
P-414
P-604
2"
2"
2"
2"
2"
4"
6"
1ST FLR
1.5"
2"
2"
2"
2"
2"
EXISTING VENT RISER
EXISTING VENT RISER
V
V
V
V
SAN
SAN
SAN
SAN
SAN
V
V
V
SAN
SAN
V
V
V
SAN
2"
1.5"
1ST FLR
1ST FLR
FD-1
3"
2"
FD-1
4"
P-528
2ND FLR
2"
P-528
2"
1ST FLR
2"
4"
BSMT
4"
4"4"
2"
4"
2" 3"
P-414
P-414
2ND FLR
P-106L
P-106R
2"
3"
3" 2ND FLR
3"
P-414
P-414
2"1ST FLR
P-106R
P-106L
3"
4"
4"
P-502
P-528
1.5"
3"
3"
1.5" 4"
FD-E
4"
4"
6"
1.5"
1.5"
1.5"
1.5"
1ST FLR
1ST FLR
P-608
P-528
1ST FLR
2ND FLR
2ND FLR
1.5"
1.5"
3"VTR
3"
2"
2"
1.5"
3"VTR
3"
BSMT
3"
BSMT
2"
4"
2"
2"
2"
BSMT
2"
2"
3"
PLUGGED FLOOR DRAIN
SAN
SAN
SAN
SAN
SAN
FD-E
4"
4"
3" HD
2"2"
2ND FLR
3"
CAP
CO
2"
CO
2"
4"
CO
4"
RD1
OD1
2ND FLR
1ST FLR
4"
4"
4"
4" 4"
4"
4"
EXTERIOR WALL
1ST FLR
CO
CO
4"
4"
2ND FLR
4"
OD1
4"
CO
4"
4"
SC1
SC1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/1 /2
:3
:2
P M
P901
DRAINAGE ISOMETERIC
07/01/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
BID DOCUMENTSJAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
SCALE: NONE
DRAINAGE ISOMETRIC - LOBBY
PLAN NOTES
1. CAPPED AT GRADE.
SCA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .