Atch 30 AMEND_3 _ 10.08_FX102 - BALCONY 2nd FLOOR - CEILING.pdf
PDF 774 KB Posted
- Solicitation number
- 36C24926R0055
About this file
This is an architectural drawing set for the U.S. Department of Veterans Affairs James H. Quillen VA Medical Center. The document consists of three detailed mechanical, electrical, and plumbing (MEP) plans for the restoration of Building 35 Theater at the Mountain Home, Tennessee facility.
The drawings include: (1) a Balcony and Second Floor Plan at 1/8" = 1'-0" scale showing lobby, mech/elec room, balcony, dressing rooms, toilets, corridors, and projector booth with fire suppression systems including FDV standpipes and dry-pipe risers serving various zones; (2) a Projector Booth Plan at the same scale detailing mechanical and electrical infrastructure in that space; and (3) a Ceiling and Catwalk New Work Plan showing overhead distribution systems and support infrastructure. The plans are marked "NOT FOR CONSTRUCTION" and labeled as 100% Construction Documents dated 05/30/2025, representing the final phase of a multi-stage design process that began with 25% Schematic Design on 10/31/2024. The project is designated VAMC 2024-05141, with the consulting firm being FFE and the architect/engineer of record being Heapy. All plans are fully sprinklered and show comprehensive fire suppression system routing throughout the theater spaces and support areas.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOBBY
MECH/ELEC
BALCONY
DRESSING
ROOM
TOILET
TOILET
CORRIDOR
DRESSING
ROOM
OH
OH
OH
4 1
OPEN TO ABOVE & BELOWOPEN TO AUDITORIUM BELOW
FDV STANDPIPE UP.
SERVES FDV
ABOVE CATWALK.
DRY-PIPE RISER.
SERVES AUDITORIUM
ATTIC SPACE.
FDV STANDPIPE UP.
SERVES FDV
ABOVE CATWALK.
DS DN
F201
F201
DRY-PIPE RISER .
SERVES SPRINKLERS
BELOW CATWALK
DRY-PIPE RISER.
SERVES BELOW CATWALK,
AUDITORIUM ATTIC SPACE,
BELOW STAGE ATTIC AND
STAGE ATTIC.
GENERAL NOTES
A. REFER TO SHEET F001 FOR ABBREVIATIONS, LEGEND & DESIGN NOTES.
B. UTILIZE EXISTING SPRINKLER LOCATIONS WHERE POSSIBLE IN AUDITORIUM AND LOBBY CEILINGS.
C. FOLLOW EXISTING EXPOSED BRANCH AND MAIN PIPE ROUTING IN AUDITORIUM AND LOBBY.
D. EXPOSED PIPING SHALL MATCH ADJACENT PAINTED SURFACES.
E. SPRINKLER PIPING TO BE ROUTED IN CEILING WHERE CEILING SPACE ALLOWS. ( ROOMS 110, 110A, 111, 111A,104, 105, 106, 108 & 109.)
F. UTILIZE EXISTING TEST LOCATIONS AND DRAIN ROUTING.
PROJECTOR
BOOTH
OH
LOBBY
DN
DN
DN
DN
DN
OPEN TO ABOVE & BELOW
FDV STANDPIPE
FDV STANDPIPE
FDV
FDV
CATWALK
CATWALK
UP
DNUP
DRY-PIPE RISER UP.
SERVES AUDITORIUM
ATTIC SPACE.
F201
F201
DRY-PIPE RISER.
SERVES BELOW STAGE ATTIC
AND STAGE ATTIC SPACE.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT F
OR C
ONSTRUCTIO
N
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/2
/2
:0
:4
P
M
FX102
BALCONY, SECOND FLOOR AND
CEILING NEW WORK PLANS
05/30/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
100% CONSTRUCTION
DOCUMENTS 35
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT F
OR C
ONSTRUCTIO
N
Date:Revisions:No.
PROJECT NO.
A u to d e s k D o c s /M t H o m e V
A
R e s to ra ti o n o f B
T h e a te r/
-0
-M
E P
-C e n tr a l.
rv t
/2
/2
:0
:4
P
M
FX102
BALCONY, SECOND FLOOR AND
CEILING NEW WORK PLANS
05/30/2025 EWL RLC
RESTORATION OF BUILDING 35
HISTORIC THEATER
621-24-103
MT. HOME, TENNESSEE
100% CONSTRUCTION
DOCUMENTS 35
JAMES H.
QUILLEN VA
MEDICAL
CENTER
Approved: VAMC
2024-05141
SCALE: 1/8" = 1'-0"
BALCONY AND SECOND FLOOR PLAN
PLAN NOTES
SCALE: 1/8" = 1'-0"
PROJECTOR BOOTH PLAN
1. PROVIDE NEW DRY-PIPE SPRINKLER SYSTEM (SIZED PER HYDRAULIC CALCULATIONS) COMBINED WITH WET-STANDPIPE SYSTEM
(STAGE AREA ONLY) TO SERVE BUILDING.
2. ONLY SPRINKLER PIPING SERVING ROOM'S SPRINKLER(S) SHALL BE EXTEND ABOVE THIS ROOM. PIPING
SHALL NOT BE LOCATED DIRECTLY OVER ELECTRICAL EQUIPMENT.
3. HARD CEILING IN THIS LOCATION (GYPSUM BOARD/ PLASTER/ WOOD). REFER TO ARCHITECTURAL
DRAWINGS FOR ADDITIONAL INFORMATION.
4. PROVIDE FACTORY COLORED SPRINKLERS IN LOBBY AND AUDITORIUM (SHOP OR FIELD PAINTING IS NOT PERMITTED.). MATCH ADJACENT PAINTED SURFACES. NON-COLORED SPRINKLERS PERMITTED IN ATTIC, RAFTERS, STAGE, BACK OF HOUSE, MECHANICAL, ELECTRICAL, CRAWLS SPACE AND PROJECTION ROOMS.
5. RE-USE AS MANY EXISTING SPRINKLER LOCATIONS IN AUDITORIUM AND LOBBY AS POSSIBLE. RUN PIPING EXPOSED UTILIZING THE EXISTING ROUTING WHERE POSSIBLE. RE-USE EXISTING FDV STANDPIPE LOCATIONS UNLESS OTHERWISE NOTED.
6. RE-USE EXISTING FDV STANDPIPE LOCATIONS UNLESS OTHERWISE NOTED.
7. ROUTE SPRINKLER PIPE EXPOSED.
8. PROJECTION BOOTH ABOVE. REFER 2/FX102.
SCALE: 1/8" = 1'-0"
CEILING AND CATWALK NEW WORK PLAN
25% SCHEMATIC DESIGN 10/31/2024
75% DESIGN DEVELOPMENT 01/29/2025
95% CONSTRUCTION DOCUMENTS 03/31/2024
100% CONSTRUCTION DOCUMENTS 05/30/2025
25% SCHEMATIC DESIGN 10/31/2024
75% DESIGN DEVELOPMENT 01/29/2025
95% CONSTRUCTION DOCUMENTS 03/31/2024
100% CONSTRUCTION DOCUMENTS 05/30/2025
| Sheets |
| FX102 - BALCONY, SECOND FLOOR AND CEILING NEW WORK PLANS |
File details come from the government source that posted it. Updated .