Text version
Location Description RP Unique ID Primary Category Code
Primary Category Code Description
Height Scope Street Address City State (Site)
Latitude Longitude Picture
TOWER - 30' (GT) -
(ELLIS LOOKOUT)
18028 132-03 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
Burnt Mountain Rd Beaver WA 48.129789 -124.305958
RADIO BEACON TOWER
- 120' (GT) - (CAPE
FLATTERY LIGHT)
18046 132-04
Guyed Communication Tower (100 ft to 299 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
TATOOSH ISLAND Neah Bay WA 48.392004 -124.736871
CAMS TOWER - 35'
(GT) - (HAMMOND
NAVTEX)
44217 132-03 Guyed Communication Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Remove vegetation contacting guy wires
d. Replace all three wood support poles with climbing pegs and safety climb systems.
d. Install ice clips Immediate QTY. (36)
e. Remove excessively grown vegetation within tower compound and at the guy anchors.
f. Inspection and Maintenance Report
320 Lake Dr Hammond OR 46.203975 -123.956162
74603-74819 Oregon Coast Hwy
Reedsport OR 43.657421 -124.187737
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Replace bent shackle bolts on guy wires A and B
d. Replace rigid rail safety climb system
e. Replace 5/8” Ø x 1-3/4” bolts assemblies and include nut locking devices on mount at 101’
f. Tighten fasteners of mount hardware
g. Prep, clean, and paint the tower IAW Section 3.2.1.1.
h. Clean and galvanize surface corrosion, replace hardware where section loss is present
i. Replace all cotter pins at guy level 1
j. Replace waterfall grounding at anchor B
k. Remove unused and cut mounts on A leg and the CD face of the tower at elevations 33’ and 45’.
l. Replace mount pipe on leg A at 99'
m. Remove cut coax at elevations 5’, 35', and 98'. Remove unused coax clips and replace corroded coax clips still in use.
n. Replace cable clamps at anchor B.
p. Provide engineering analysis on the current condition of the tower base.
q. Remove overgrown vegetation around all guy anchors
r. Reinforce bent acnhor rod A
s. Clean and coat all anchor rods
t. Inspection and Maintenance Report
TOWER - 128' (GT) -
(WINCHESTER HILL)
17908 132-04
Guyed Communication
Tower (100 ft to 299 ft)
Category Code
Primary Category Code Description
Height Scope Street Address City State (Site)
Latitude Longitude Picture
TOWER - 50' (SST) 46051 132-03
Guyed Communication Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
SMITH ISLAND Oak Harbor WA 48.318484 -122.843639
VTS TOWER - 90' 46052 132-01
Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
Smith Island Oak Harbor WA 48.319727 -122.842351
TOWER - 30' (SST) -
(NORTH BEND EAST)
69951 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
91100 Cape Blanco Rd Sixes OR 42.836616 -124.563214
CMD CEN TOWER
STATION QUILLAYUTE
RIVER WEST
70069 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
350 MAIN ST. La Push WA 47.913338 -124.634193
Category Code
Primary Category Code Description
Height Scope Street Address City State (Site)
Latitude Longitude Picture
CMD CEN TOWER
(LOCAL MCX)
70067 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
350 MAIN ST. La Push WA 47.913153 -124.634183
CMD CEN TOWER
AIRSTA PORT ANGELES
(NDB)
70098 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
1 EDIZ HOOK RD
98362-2201
Port Angeles WA 48.139903 -123.4023
CMD CEN TOWER
STATION BELLINGHAM
810120 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
28 BELLWETHER WAY Bellingham WA 48.755155 -122.493453
CMD CEN TOWER 840562 132-01
Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
240 Coast Guard Dr.
97341-1922
Depoe Bay OR 44.809905 -124.058897
Category Code
Primary Category Code Description
Height Scope Street Address City State (Site)
Latitude Longitude Picture
CMD CEN TOWER
STATION COOS BAY
WEST
840634 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
390 1st Street SW Bandon OR 43.120215 -124.418005
ATON TRAINING
TOWER
852031 179-23 Miscellaneous Training Facility
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
434 Clover Island Drive Kennewick WA 46.21682 -119.109797