Site Master Inc. Proprietary & Confidential
Page | 2
II – Table of Contents
Section Page Title Page
I Title Page 1
II Table of Contents 2
III Executive Summary 3
IV Recommended Maintenance 5
V Chronological Narrative 5
Appendices Page
A Tower Inspection Photographs 6
B Tower Height Verification Form 17
C Tower Condition Assessment Form 18
D Repair Estimate(s) Sheet 19
Site Master Inc. Proprietary & Confidential
Page | 3
III - Executive Summary
i. Inspection Summary
The R21 Cambria tower located in Cambria, CA was inspected on July 28, 2016 by SiteMaster, Inc. crew members. The structure is a 100’ self supporting tower. The overall condition of the tower structure was found to be fair-to-satisfactory with a few maintenance items noted. Unrelated to the tower’s condition: there are some equipment items in the compound (generator and electrical box on shelter) which have a heavy amount of rust.
ii. Structural Members
The structural members of the tower were in good condition. There was no rust present on the tower steel. However, tower leg A’s foundation—the same leg as the safety climb—is covered in rust due to run-off from the rusty safety climb and will need to be scraped and cold galvanized. All hardware was tight and none was found to be missing.
The structural steel of the tower was free of deviations and in good condition. All hardware throughout the tower was either anchor nut or double nut secured. The tower foundations appeared to be in good condition (apart from the aforementioned rust on tower leg A’s foundation) and showed no signs of cracking. The tower galvanization is still in good condition.
iii. Alignment and Twist
A visual inspection of the tower showed that it appeared to be plumb.
iv. FAA Obstruction Lighting System
Not applicable on this tower.
v. Guy System and Guy Hardware
Not applicable on this tower.
vi. Guy Anchors and Foundation
Not applicable on this tower.
vii. Insulator Systems
Not applicable on this tower.
viii. Grounding Systems
There were no noted deficiencies in the grounding system. A lightning rod is installed at the top of the tower.
Site Master Inc. Proprietary & Confidential
Page | 4
ix. OSHA Standards
The tower is equipped with climbing pegs and a safety climb cable system. The cable is rusted and will need to be replaced. There is a bent peg at 28’ needing to be replaced.
x. Maintenance Accomplished
No on-site minor maintenance was needed.
Site Master Inc. Proprietary & Confidential
Page | 5
IV – Recommendations
Within 1 Year:
1. Replace the rusted safety climb cable system.
2. Scrape the rusted tower foundation and apply cold galvanization compound.
3. Replace the bent foot peg at 28’.
V – Chronological Narrative
Date: 7/28/16
Weather Conditions: Sunny Wind: 2MPH
Time Work Performed
0800-0830 Arrived on site; safety meeting
0830-0945 Performed tower and ground inspection
0945 Left site
Site Master Inc. Proprietary & Confidential
Page | 6
Appendix A Tower Inspection Photographs
Overall View of Tower
Site Master Inc. Proprietary & Confidential
Page | 7
No. Description Photograph
1 Tower ID; written as no tag present
2 View looking up the tower; rusted safety climb
3 Tower foundation and grounding
Site Master Inc. Proprietary & Confidential
Page | 8
4 Tower foundation and grounding
5 Tower foundation and grounding
6 Overall base of tower
Site Master Inc. Proprietary & Confidential
Page | 9
7 Coax routing from shelter to tower
8 Coax routing into shelter
9 Laser reading for height verification
Site Master Inc. Proprietary & Confidential
Page | 10
10 Equipment shelter
11 Equipment shelter
12 Bent foot peg at 28’
Site Master Inc. Proprietary & Confidential
Page | 11
13 Top of tower
14 Typical good condition of tower bolt hardware
15 Typical good condition of tower bolt hardware
Site Master Inc. Proprietary & Confidential
Page | 12
16 Typical good condition of tower steel
17 R21 antenna at top of tower
18 Omni mount at 83’
Site Master Inc. Proprietary & Confidential
Page | 13
19 Omni and dipole at 83’
20 Dipole at 63’
View looking down the tower; rusted safety climb cable
Site Master Inc. Proprietary & Confidential
Page | 14
22 Coax routing on the tower
23 Rusted generator in compound
24 Rusted electrical box on shelter
Site Master Inc. Proprietary & Confidential
Page | 15
25 H-frame in compound
26 H-frame in compound
27 Overall compound
Site Master Inc. Proprietary & Confidential
Page | 16
28 Interior view of compound
29 Interior view of compound
30 Interior view of compound
Site Master Inc. Proprietary & Confidential
Page | 17
Appendix B
Site Master Inc. Proprietary & Confidential
Page | 18
Appendix C