Location Description
RP Unique
ID
Primary Category Code
Primary Category Code Description
Height Scope Street Address City State (Site) Latitude Longitude Picture
CAMS TOWER (RX) 15255 132-04 Guyed Communication Tower (100 ft to 299 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Install proper grounding at pole 2 of element 2, anchor B, and anchor CC.
d. Install ice clips at preforms of anchor A
e. Properly serve ends of all guy wires
f. Inspection and Maintenance Report
17000 SIR FRANCIS
DRAKE BLVD
Inverness CA 38.103136 -122.937651
CAMS TOWER (RX
MULTIMODE
SPIRAL)
15259 132-04 Guyed Communication Tower (100 ft to 299 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Replace ground leads on anchors 2 and 4
d. Replace all preforms to allow for turnbuckle adjustment
e. Repair damage to compound fence
f. Trim excessively grown vegetation
g. Install nut locking devices on turnbuckles
h. Inspection and Maintenance Report
17000 SIR FRANCIS
DRAKE BLVD
Inverness CA 38.102104 -122.936127
CAMS TOWER (RX
OMNI)
15261 132-04 Guyed Communication Tower (100 ft to 299 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Provide cost estimate to replace (6) wooden support poles
d. Clean and galvanize guy hardware at top of wooden support poles (manlift required)
e. Replace broken ground leads at base of the tower.
f. Replace preforms and re-tension (3) guy wires
g. Trim excessively grown vegetation within compound.
h. Inspection and Maintenance Report
17000 SIR FRANCIS
DRAKE BLVD
Inverness CA 38.106346 -122.93504
CAMS TOWER (TCI
VOBA #3)
15290 132-03 Guyed Communication Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Install nut locking devices on all flange/bracing bolts.
d. Install thimbles at elevation 30’ and at all anchors.
e. Install ice clips at all bottom wire connection preforms.
f. Install wire rope clips at each of the safety wire location.
g. Install wire servings at all bottom wire connection preforms.
h. Replace the preform associated with the inner guy wire at 340 degrees with a new preform with the same lay as the wire. Install new preforms at the outer turnbuckle at 340 degrees.
i. Properly install/replace the wire clip associated with inner guy wire at 340 degrees. Apply cold galvanizing compound to all the corroded areas. Install locking devices on the ground shackles.
j. Inspection and Maintenance Report
525 Mesa Road Bolinas CA 37.92611 -122.731682
CAMS TOWER (TCI
VOBA #7)
15297 132-03 Guyed Communication Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Prep, clean, and paint the tower IAW Section 3.2.1.1.
d. Replace bent ground plate and broken ground leads.
e. Install nut locking devices on all turnbuckle bolts.
f. Replace safety wires at all turnbuckles and install wire rope clips on safety wires.
g. Install thimbles and ice clips on all preforms
h. Serve dead ends of guy wires at all ground preforms.
i. Install thimbles to all outer guy wires
j. Replace pal nuts on all guy lugs
k. Inspection and Maintenance Report
525 Mesa Road Bolinas CA 37.923308 -122.732665
RP Unique
ID
Primary Category Code
Primary Category Code Description
Height Scope Street Address City State (Site) Latitude Longitude Picture
CAMS TOWER (API
VOBA #3)
15301 132-03 Guyed Communication Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Replace (6) safety climb cable systems on 40’ wooden poles
d. Replace 5/8” dia. X 12” threaded rods on (4) collar mounts on on wooden poles 1, 2, 5, and 6.
e. Replace (30) broken ground leads
f. Replace safety wires at all turnbuckles and install wire rope clips on safety wires.
g. Replace bent 3/4" x 12" turnbuckle at outer guy wire # 6
h. Replace bent thimbles at outside guy anchors 1 and 5.
i. Properly serve wire ends at inside anchor 1, and outside anbchors 2, 3, 5, and 8.
j. Guy wire tension high due to fully extended turnbuckle
k. Exposed geofabric observed on site. Lay down 1 CY of gravel over fabric.
l. Earth cracking around guy anchors – Provide engineering analysis with remediation.
m. Inspection and Maintenance Report
525 MESA RD Bolinas CA 37.92399 -122.729178
TOWER 55' (GT) 17283 132-03 Guyed Communication Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Prep, clean, and paint the tower IAW Section 3.2.1.1.
d. Replace 1.3” Ø x 36” horizontal member at 20’
e. Replace safety climb system with 3/8" safety cable climb.
f. Replace (2) missing 5/8” Ø x 4” top connection bracing bolts
g. Due to corrosion, replace the follwing: 5/8”Ø x 4” L flange bolts at elevation 6’ and 40’ on C leg, 1/2”Ø x 4” L diagonal bolts at elevation 20’, 3/8”Ø thimbles for guy connections at the top of the tower, top connection bolts at the top of the tower, and 1/4" thick plate at the top of the tower.
h. Trim excessive grown vegetation around all 3 guy anchors.
i. Inspection and Maintenance Report
1 CG PRESERVATION RD Trinidad CA 41.054395 -124.150752
VTS TOWER - 40'
(SST) - (MARE
ISLAND)
18923 132-03 Guyed Communication Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
Jennings Road Vallejo CA 38.06955 -122.25136
MICROWAVE
TOWER #2
21206 132-03 Guyed Communication Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Perform a corrosion inspection and determine if the tower is strucutrually sound to be prepared, cleaned and painted.
d. Install lightning rod so that it is the tallest appurtenance on the structure.
e. Repair/replace 50 LF of the compound fence in locations that have failed and are failing.
f. Remove excessive vegetative growth within the compound
g. Inspection and Maintenance Report
27000 Sir Francis Drake Blvd
Inverness CA 37.99706 -123.0132
CMD CEN TOWER
#1 (A), BASE LA/LB
NORTH
25042 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
1001 S. Seaside Avenue San Pedro CA 33.727047 -118.269198
RP Unique
ID
Primary Category Code
Primary Category Code Description
Height Scope Street Address City State (Site) Latitude Longitude Picture
CMD CEN TOWER
SECTOR SAN DIEGO
NORTH
27219 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
2710 North Harbor Dr.
92101-1028
San Diego CA 32.726509 -117.183225
CMD CEN TOWER
BASE ALAMEDA
WEST
69892 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
COAST GUARD ISLAND
94501-5101
Alameda CA 37.784321 -122.250329
CAMS TOWER (TX
#25)
70118 132-03 Guyed Communication Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Provide cost estimate to replace all wooden support poles
d. Replace safety wires at all turnbuckles and install wire rope clips on safety wires.
e. Install ice clips on all anchor preforms.
f. Replace shackles on support poles (Manlift required)
g. Repair cracks on wood pole anchor #1 in concrete with grout.
h. Repair effected areas of concrete with grout on wood pole anchor # 2.
i. Inspection and Maintenance Report
525 MESA RD Bolinas CA 37.92435 -122.7338
MICROWAVE
TOWER (ON B001)
70119 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
17000 Sir Francis Drake Blvd.
Inverness CA 38.104068 -122.936535
MICROWAVE
TOWER (Located at loading dock)
70120 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
26450 Sir Francis Drake Blvd
Inverness CA 38.103498 -122.936107
RP Unique
ID
Primary Category Code
Primary Category Code Description
Height Scope Street Address City State (Site) Latitude Longitude Picture
R21 TOWER SAN
ONOFRE PEAK
813509 132-02 Self-Supporting Communication Tower (100 ft to 299
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Replace bent ste peg on the A leg at 88'
c. Inspection and Maintenance Report
San Onofre Peak 92055-0001
Camp Pendleton
CA 33.362289 -117.496114
R21 TOWER
CAMBRIA
813531 132-02 Self-Supporting Communication Tower (100 ft to 299
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
222 Monte Cristo Place 93428-5006
Cambria CA 35.518528 -121.059944
R21 TOWER - 80'
(SST) - (MT.
UMUNHUM)
813540 132-01 Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
Loma Almaden Road Los Gatos CA 37.159583 -121.90925
R21 TOWER 813559 132-01
Self-Supporting Communications Tower (up to 99 ft)
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
14500 Meyers Grade Rd Jenner CA 38.495872 -123.184522
ET CLIMBING
TOWER TRAINER
814044 179-23 Miscellaneous Training Facility
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Inspection and Maintenance Report
599 TOMALES RD Petaluma CA 38.250388 -122.79983
RP Unique
ID
Primary Category Code
Primary Category Code Description
Height Scope Street Address City State (Site) Latitude Longitude Picture
TOWER- 65' (SST) -
MULTIPLE RAISED
PLATFORMS
847597 132-09 Raised Tower Platform 40
a. General Inspection per section 3.1
b. General Maintenance per Section 3.2
c. Contractor shall have tower leg reinforcments fabricated and installed on all 4 tower legs IAC with design drawings.
c. Inspection and Maintenance Report
94952-5002 Walnut Creek CA 37.879751 -121.919617 \\D07MS-ZCEU\ Public\BMBSPublic\
CEU_Public\