Appendix A_Seed Project_USCG District 11 Towers.pdf

PDF 934 KB Posted

Attached to
Nationwide Tower/Antenna Multiple Award Construction IDIQ Contract (TMACC)
Solicitation number
70Z08822RESDV0001
Issued by

View the file

Other files

File Type Posted
70118 Final Report FY19 PMV080.pdf PDF
Amendment 0004.pdf PDF
15261 Final Report FY19 PMV080.pdf PDF
Amendment 0003.pdf PDF
44217 Final Report FY19 PMV080.pdf PDF
A001 12 847597 TOWER- 65 SST MULTIPLE RAISED PLATFORMS.pdf PDF
Amendment 0002.pdf PDF
65 SS TOWER - MT. DIABLO - STAMPED STRUCTURAL ANALYSIS.pdf PDF
70118_Final Report_FY19_PMV080.pdf PDF
15261_Final Report_FY19_PMV080.pdf PDF
21206_Final Report_FY19_PMV080.pdf PDF
17283_Final Report_FY19_PMV080.pdf PDF
15290_Final Report_FY19_PMV080.pdf PDF
17908_Final Report_FY19_PMV080.pdf PDF
813509 R21 Tower San Onofre Peak Maintenance Report.pdf PDF
44217_Final Report_FY19_PMV080.pdf PDF
15301_Final Report_FY19_PMV080.pdf PDF
813531_R21 Tower Cambria_FY16.pdf PDF
15297_Final Report_FY19_PMV080.pdf PDF
15255_Final Report_FY19_PMV080.pdf PDF
Amendment 0001- R1.pdf PDF
15259_Final Report_FY19_PMV080.pdf PDF
TOWER 65 SST MULTIPLE RAISED PLATFORMS.pdf PDF
813559_R21 Tower Mt Jenner_FY16.pdf PDF
J.3_PAST PERFORMANCE QUESTIONAIRE.docx DOCX document
Request for Proposal_70Z08822RESDV0001.pdf PDF
J.8_U.S. Tower Manual_COMDTINST M11000.4.pdf PDF
J.2_EXPERIENCE INFORMATION FORM.docx DOCX document
J.5_USCG District Map.pdf PDF
CONTRACTOR REQUEST FOR CLARIFICATION.pdf PDF
J.7_U.S. Coast Guard Safety and Environmental Health Manual_COMDTINST M5100.47.pdf PDF
Appendix A_Seed Project_USCG District 13 Towers.pdf PDF
Finalized_Source Selection Plan_TMACC.pdf PDF
Enclosure 3- Appendix D_20130812_EIS Standard Protection Measures_final.pdf PDF
1.1.3_Final Specification SEED Project for National Tower Maintenance and Inspection IDIQ Contract_FY22.pdf PDF
1.10.1_DBA_Wage Determination_Seed Project.zip ZIP file
J.6_U.S. Coast Guard Asbestos Exposure Control Manual_COMDTINST M6260-16.pdf PDF
J.1_EXPERIENCE OVERVIEW SHEET.docx DOCX document
Enclosure 3- Appendix C_GTPermittingGuidelines.pdf PDF
Enclosure 3- Appendix F_Sea Turtle and Small Tooth Sawfish Construction Conditions.pdf PDF
Enclosure 3- Appendix E_Standard Manatee Conditions for In-Water Work.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Location Description

RP Unique

ID

Primary Category Code

Primary Category Code Description

Height Scope Street Address City State (Site) Latitude Longitude Picture

CAMS TOWER (RX) 15255 132-04 Guyed Communication Tower (100 ft to 299 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Install proper grounding at pole 2 of element 2, anchor B, and anchor CC.

d. Install ice clips at preforms of anchor A

e. Properly serve ends of all guy wires

f. Inspection and Maintenance Report

17000 SIR FRANCIS

DRAKE BLVD

Inverness CA 38.103136 -122.937651

CAMS TOWER (RX

MULTIMODE

SPIRAL)

15259 132-04 Guyed Communication Tower (100 ft to 299 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Replace ground leads on anchors 2 and 4

d. Replace all preforms to allow for turnbuckle adjustment

e. Repair damage to compound fence

f. Trim excessively grown vegetation

g. Install nut locking devices on turnbuckles

h. Inspection and Maintenance Report

17000 SIR FRANCIS

DRAKE BLVD

Inverness CA 38.102104 -122.936127

CAMS TOWER (RX

OMNI)

15261 132-04 Guyed Communication Tower (100 ft to 299 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Provide cost estimate to replace (6) wooden support poles

d. Clean and galvanize guy hardware at top of wooden support poles (manlift required)

e. Replace broken ground leads at base of the tower.

f. Replace preforms and re-tension (3) guy wires

g. Trim excessively grown vegetation within compound.

h. Inspection and Maintenance Report

17000 SIR FRANCIS

DRAKE BLVD

Inverness CA 38.106346 -122.93504

CAMS TOWER (TCI

VOBA #3)

15290 132-03 Guyed Communication Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Install nut locking devices on all flange/bracing bolts.

d. Install thimbles at elevation 30’ and at all anchors.

e. Install ice clips at all bottom wire connection preforms.

f. Install wire rope clips at each of the safety wire location.

g. Install wire servings at all bottom wire connection preforms.

h. Replace the preform associated with the inner guy wire at 340 degrees with a new preform with the same lay as the wire. Install new preforms at the outer turnbuckle at 340 degrees.

i. Properly install/replace the wire clip associated with inner guy wire at 340 degrees. Apply cold galvanizing compound to all the corroded areas. Install locking devices on the ground shackles.

j. Inspection and Maintenance Report

525 Mesa Road Bolinas CA 37.92611 -122.731682

CAMS TOWER (TCI

VOBA #7)

15297 132-03 Guyed Communication Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Prep, clean, and paint the tower IAW Section 3.2.1.1.

d. Replace bent ground plate and broken ground leads.

e. Install nut locking devices on all turnbuckle bolts.

f. Replace safety wires at all turnbuckles and install wire rope clips on safety wires.

g. Install thimbles and ice clips on all preforms

h. Serve dead ends of guy wires at all ground preforms.

i. Install thimbles to all outer guy wires

j. Replace pal nuts on all guy lugs

k. Inspection and Maintenance Report

525 Mesa Road Bolinas CA 37.923308 -122.732665

RP Unique

ID

Primary Category Code

Primary Category Code Description

Height Scope Street Address City State (Site) Latitude Longitude Picture

CAMS TOWER (API

VOBA #3)

15301 132-03 Guyed Communication Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Replace (6) safety climb cable systems on 40’ wooden poles

d. Replace 5/8” dia. X 12” threaded rods on (4) collar mounts on on wooden poles 1, 2, 5, and 6.

e. Replace (30) broken ground leads

f. Replace safety wires at all turnbuckles and install wire rope clips on safety wires.

g. Replace bent 3/4" x 12" turnbuckle at outer guy wire # 6

h. Replace bent thimbles at outside guy anchors 1 and 5.

i. Properly serve wire ends at inside anchor 1, and outside anbchors 2, 3, 5, and 8.

j. Guy wire tension high due to fully extended turnbuckle

k. Exposed geofabric observed on site. Lay down 1 CY of gravel over fabric.

l. Earth cracking around guy anchors – Provide engineering analysis with remediation.

m. Inspection and Maintenance Report

525 MESA RD Bolinas CA 37.92399 -122.729178

TOWER 55' (GT) 17283 132-03 Guyed Communication Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Prep, clean, and paint the tower IAW Section 3.2.1.1.

d. Replace 1.3” Ø x 36” horizontal member at 20’

e. Replace safety climb system with 3/8" safety cable climb.

f. Replace (2) missing 5/8” Ø x 4” top connection bracing bolts

g. Due to corrosion, replace the follwing: 5/8”Ø x 4” L flange bolts at elevation 6’ and 40’ on C leg, 1/2”Ø x 4” L diagonal bolts at elevation 20’, 3/8”Ø thimbles for guy connections at the top of the tower, top connection bolts at the top of the tower, and 1/4" thick plate at the top of the tower.

h. Trim excessive grown vegetation around all 3 guy anchors.

i. Inspection and Maintenance Report

1 CG PRESERVATION RD Trinidad CA 41.054395 -124.150752

VTS TOWER - 40'

(SST) - (MARE

ISLAND)

18923 132-03 Guyed Communication Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

Jennings Road Vallejo CA 38.06955 -122.25136

MICROWAVE

TOWER #2

21206 132-03 Guyed Communication Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Perform a corrosion inspection and determine if the tower is strucutrually sound to be prepared, cleaned and painted.

d. Install lightning rod so that it is the tallest appurtenance on the structure.

e. Repair/replace 50 LF of the compound fence in locations that have failed and are failing.

f. Remove excessive vegetative growth within the compound

g. Inspection and Maintenance Report

27000 Sir Francis Drake Blvd

Inverness CA 37.99706 -123.0132

CMD CEN TOWER

#1 (A), BASE LA/LB

NORTH

25042 132-01 Self-Supporting Communications Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

1001 S. Seaside Avenue San Pedro CA 33.727047 -118.269198

RP Unique

ID

Primary Category Code

Primary Category Code Description

Height Scope Street Address City State (Site) Latitude Longitude Picture

CMD CEN TOWER

SECTOR SAN DIEGO

NORTH

27219 132-01 Self-Supporting Communications Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

2710 North Harbor Dr.

92101-1028

San Diego CA 32.726509 -117.183225

CMD CEN TOWER

BASE ALAMEDA

WEST

69892 132-01 Self-Supporting Communications Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

COAST GUARD ISLAND

94501-5101

Alameda CA 37.784321 -122.250329

CAMS TOWER (TX

#25)

70118 132-03 Guyed Communication Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Provide cost estimate to replace all wooden support poles

d. Replace safety wires at all turnbuckles and install wire rope clips on safety wires.

e. Install ice clips on all anchor preforms.

f. Replace shackles on support poles (Manlift required)

g. Repair cracks on wood pole anchor #1 in concrete with grout.

h. Repair effected areas of concrete with grout on wood pole anchor # 2.

i. Inspection and Maintenance Report

525 MESA RD Bolinas CA 37.92435 -122.7338

MICROWAVE

TOWER (ON B001)

70119 132-01 Self-Supporting Communications Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

17000 Sir Francis Drake Blvd.

Inverness CA 38.104068 -122.936535

MICROWAVE

TOWER (Located at loading dock)

70120 132-01 Self-Supporting Communications Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

26450 Sir Francis Drake Blvd

Inverness CA 38.103498 -122.936107

RP Unique

ID

Primary Category Code

Primary Category Code Description

Height Scope Street Address City State (Site) Latitude Longitude Picture

R21 TOWER SAN

ONOFRE PEAK

813509 132-02 Self-Supporting Communication Tower (100 ft to 299

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Replace bent ste peg on the A leg at 88'

c. Inspection and Maintenance Report

San Onofre Peak 92055-0001

Camp Pendleton

CA 33.362289 -117.496114

R21 TOWER

CAMBRIA

813531 132-02 Self-Supporting Communication Tower (100 ft to 299

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

222 Monte Cristo Place 93428-5006

Cambria CA 35.518528 -121.059944

R21 TOWER - 80'

(SST) - (MT.

UMUNHUM)

813540 132-01 Self-Supporting Communications Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

Loma Almaden Road Los Gatos CA 37.159583 -121.90925

R21 TOWER 813559 132-01

Self-Supporting Communications Tower (up to 99 ft)

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

14500 Meyers Grade Rd Jenner CA 38.495872 -123.184522

ET CLIMBING

TOWER TRAINER

814044 179-23 Miscellaneous Training Facility

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Inspection and Maintenance Report

599 TOMALES RD Petaluma CA 38.250388 -122.79983

RP Unique

ID

Primary Category Code

Primary Category Code Description

Height Scope Street Address City State (Site) Latitude Longitude Picture

TOWER- 65' (SST) -

MULTIPLE RAISED

PLATFORMS

847597 132-09 Raised Tower Platform 40

a. General Inspection per section 3.1

b. General Maintenance per Section 3.2

c. Contractor shall have tower leg reinforcments fabricated and installed on all 4 tower legs IAC with design drawings.

c. Inspection and Maintenance Report

94952-5002 Walnut Creek CA 37.879751 -121.919617 \\D07MS-ZCEU\ Public\BMBSPublic\

CEU_Public\