This document provides details for a federal contract solicitation to construct balance of work at the Veterans Affairs Medical Center in Manhattan, New York. The solicitation number is 36C10F24R50018 and is being issued by the Department of Veterans Affairs Office of Construction and Facilities Management. The work involves completing the Manhattan Hurricane Sandy Recovery Program at the VAMC Manhattan campus and constructing remaining facilities damaged by the hurricane. Responses are due by the date listed on the solicitation. The selected contractor will be awarded a contract to perform the construction services at a price to be negotiated with the agency.

View the file

Other files

File Type Posted
SolicitationCancellation.pdf PDF
SolicitationAmendment0006.pdf PDF
Manhattan VA Asbestos Survey Report 05-2021final (5-24-21).pdf PDF
Manhattan VA Revised Asbestos Survey Report 05-2021Final (Appendix H - First Half).pdf PDF
QA - Balance of Work - 05.08.2024.pdf PDF
Manhattan VA Revised Asbestos Survey Report 05-2021Final (Appendix H - 2nd half).pdf PDF
QA - Balance of Work - 05.02.2024.pdf PDF
SolicitationAmendment0005.pdf PDF
SolicitationAmendment0004.pdf PDF
QA - Balance of Work - 04.16.2024.pdf PDF
C-Mechanical- Part 2.pdf PDF
C-Electrical- Part 5.pdf PDF
B-Mechanical-Part 1.pdf PDF
P03_CDR- Sole Source JA - Access Controls - 11-16-22.pdf PDF
B-Civil.pdf PDF
C-Plumbing- Part 2.pdf PDF
P03_CDR - Sole Source JA - Public Announcement System - 11-16-22.pdf PDF
C-Electrical- Part 4.pdf PDF
A-Architecture-Part 3.pdf PDF
A-ICRA.pdf PDF
C-Architecture- Part 5.pdf PDF
A-Fire Protection-Part 2.pdf PDF
C-Electrical- Part 10.pdf PDF
P03_CDR - Sole Source JA - Triplex Pump 11-16-22.pdf PDF
C-Life Safety.pdf PDF
A-Electrical-Part 1.pdf PDF
VHA Directive 1028_D_2020-02-24.pdf PDF
B-Electrical-Part 2.pdf PDF
B-Architecture-Part 4.pdf PDF
C-Electrical- Part 12.pdf PDF
A-Electrical-Part 3.pdf PDF
C-Electrical- Part 7.pdf PDF
C-Electrical- Part 8.pdf PDF
A-Civil.pdf PDF
A-Structural.pdf PDF
A-General.pdf PDF
QSE 36C10F24R50018.pdf PDF
Amendment 0001 - Missing and Replacement Documents.pdf PDF
B-Electrical-Part 1.pdf PDF
C-Fire Protection- Part 2.pdf PDF
C-Electrical- Part 11.pdf PDF
C-Telecom.pdf PDF
A-Plumbing-Part 2.pdf PDF
C-Architecture- Part 6.pdf PDF
B-Electrical-Part 3.pdf PDF
VAMC CD Refresh IFC Vol 1 Specifications REV 2_ 9-19-23 (Part 3).pdf PDF
C-Mechanical- Part 3.pdf PDF
Shutdown Request Form.pdf PDF
B-Architecture-Part 2.pdf PDF
P03_CD Refresh - Sole Source JA - Fire Alarm System - 11-16-22.pdf PDF
Show 40 more

Latest 50 of 281 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

Key Plan

Balance of Work

9/12/2022 TM KS

A-P001

PLUMBING SYMBOLS ABBREVIATIONS

AND GENERAL NOTES

AutoCAD SHX Text

GENERAL PLUMBING NOTES

AutoCAD SHX Text

BACK FLOW PREVENTOR

AutoCAD SHX Text

PRESSURE & TEMPERATURE RELIEF VALVE

AutoCAD SHX Text

PRESSURE RELIEF VALVE

AutoCAD SHX Text

BACK FLOW PREVENTOR ASSEMBLY

AutoCAD SHX Text

PRV

AutoCAD SHX Text

P&T RV

AutoCAD SHX Text

BFP

AutoCAD SHX Text

HEAT TRACE

AutoCAD SHX Text

OUTSIDE SCREW & YOKE VALVE

AutoCAD SHX Text

OS&Y

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

PIPE ELBOW UP, 90%%D OR 45%%D

AutoCAD SHX Text

PIPE ELBOW DOWN, 90%%D OR 45%%D

AutoCAD SHX Text

PIPE TEE UP

AutoCAD SHX Text

PIPE TEE DOWN

AutoCAD SHX Text

AUTOMATIC THREE-WAY CONTROL VALVE

AutoCAD SHX Text

CHECK VALVE (ARROW INDICATES DIRECTION OF FLOW)

AutoCAD SHX Text

ANGLE GATE VALVE

AutoCAD SHX Text

BALANCING VALVE

AutoCAD SHX Text

BACKWATER VALVE

AutoCAD SHX Text

BALL VALVE

AutoCAD SHX Text

AUTOMATIC TWO-WAY CONTROL VALVE

AutoCAD SHX Text

GLOBE VALVE

AutoCAD SHX Text

SHUT-OFF VALVE

AutoCAD SHX Text

BALANCING VALVE

AutoCAD SHX Text

GATE VALVE

AutoCAD SHX Text

MOTORIZED SHUT-OFF VALVE

AutoCAD SHX Text M

AutoCAD SHX Text

PLUMBING SYMBOLS (NOT ALL SYMBOLS USED)

AutoCAD SHX Text

HWR

AutoCAD SHX Text

HW

AutoCAD SHX Text

PIPE/EQUIPMENT TO BE REMOVED

AutoCAD SHX Text

HOT WATER

AutoCAD SHX Text

HOT WATER CIRCULATING

AutoCAD SHX Text

SANITARY DRAIN PIPE (ABOVE FLOOR)

AutoCAD SHX Text

SANITARY DRAIN PIPE (BELOW FLOOR/GRADE)

AutoCAD SHX Text

SANITARY VENT PIPE

AutoCAD SHX Text

SOLENOID VALVE

AutoCAD SHX Text S

AutoCAD SHX Text

PRESSURE REDUCING VALVE

AutoCAD SHX Text

ARROW INDICATES DIRECTION OF FLOW

AutoCAD SHX Text

SAN

AutoCAD SHX Text

SAN

AutoCAD SHX Text

RPBP

AutoCAD SHX Text

AW

AutoCAD SHX Text

ACID WASTE PIPING (BELOW FLOOR/GRADE)

AutoCAD SHX Text

AW

AutoCAD SHX Text

BV

AutoCAD SHX Text

STORM DRAIN PIPE (ABOVE FLOOR)

AutoCAD SHX Text

STORM DRAIN PIPE (BELOW FLOOR/GRADE)

AutoCAD SHX Text

ST

AutoCAD SHX Text

ST

AutoCAD SHX Text

OXYGEN

AutoCAD SHX Text O

AutoCAD SHX Text

MEDICAL VACUUM

AutoCAD SHX Text

MV

AutoCAD SHX Text

MEDICAL AIR

AutoCAD SHX Text

MA

AutoCAD SHX Text

CW

AutoCAD SHX Text

COLD WATER

AutoCAD SHX Text

ABBREV.

AutoCAD SHX Text

ABBREVIATION

AutoCAD SHX Text

MBH

AutoCAD SHX Text

THOUSAND BTU'S PER HOUR

AutoCAD SHX Text

AFF

AutoCAD SHX Text

ABOVE FINISHED FLOOR

AutoCAD SHX Text N/A

AutoCAD SHX Text

NOT APPLICABLE

AutoCAD SHX Text

AP

AutoCAD SHX Text

ACCESS PANEL

AutoCAD SHX Text

ASSE

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

BLDG

AutoCAD SHX Text

BUILDING

AutoCAD SHX Text

PD

AutoCAD SHX Text

PUMP DISCHARGE

AutoCAD SHX Text

BOP

AutoCAD SHX Text

BOTTOM OF PIPE

AutoCAD SHX Text

BTUH

AutoCAD SHX Text

BRITISH THERMAL UNIT PER HOUR

AutoCAD SHX Text

CA

AutoCAD SHX Text

COMPRESSED AIR

AutoCAD SHX Text

CFM

AutoCAD SHX Text

CUBIC FEET PER MINUTE

AutoCAD SHX Text

SAN OR S

AutoCAD SHX Text

SANITARY

AutoCAD SHX Text

CLG

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

CW

AutoCAD SHX Text

COLD WATER

AutoCAD SHX Text

TP W/DU

AutoCAD SHX Text

TRAP PRIMER VALVE DISTRIBUTION UNIT

AutoCAD SHX Text

DIA

AutoCAD SHX Text

DIAMETER

AutoCAD SHX Text U.N.O.

AutoCAD SHX Text

UNLESS NOTED OTHERWISE

AutoCAD SHX Text

DF

AutoCAD SHX Text

DRINKING FOUNTAIN

AutoCAD SHX Text V

AutoCAD SHX Text

VENT

AutoCAD SHX Text

DN

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

VTR

AutoCAD SHX Text

VENT THRU ROOF

AutoCAD SHX Text W

AutoCAD SHX Text

WASTE

AutoCAD SHX Text

EA

AutoCAD SHX Text

EACH

AutoCAD SHX Text

WH

AutoCAD SHX Text

WATER HEATER

AutoCAD SHX Text

ET

AutoCAD SHX Text

EXPANSION TANK

AutoCAD SHX Text

EJ

AutoCAD SHX Text

EJECTOR

AutoCAD SHX Text

FD

AutoCAD SHX Text

FLOOR DRAIN

AutoCAD SHX Text

GPM

AutoCAD SHX Text

GALLONS PER MINUTE

AutoCAD SHX Text

HB

AutoCAD SHX Text

HOSE BIB

AutoCAD SHX Text

HC

AutoCAD SHX Text

HANDICAPPED

AutoCAD SHX Text

HP

AutoCAD SHX Text

HORSE POWER

AutoCAD SHX Text

HW

AutoCAD SHX Text

HOT WATER

AutoCAD SHX Text

HWR

AutoCAD SHX Text

HOT WATER CIRCULATING

AutoCAD SHX Text

IN.

AutoCAD SHX Text

INCH

AutoCAD SHX Text

IW

AutoCAD SHX Text

INDIRECT WASTE

AutoCAD SHX Text

DFU

AutoCAD SHX Text

DRAINAGE FIXTURE UNITS

AutoCAD SHX Text

WSFU

AutoCAD SHX Text

WATER SUPPLY FIXTURE UNITS

AutoCAD SHX Text

INV. ELEV.

AutoCAD SHX Text

INVERT ELEVATION

AutoCAD SHX Text

NO.

AutoCAD SHX Text

NUMBER

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

MECH

AutoCAD SHX Text

DWG

AutoCAD SHX Text

DRAWING

AutoCAD SHX Text

FCO

AutoCAD SHX Text

FLOOR CLEAN OUT

AutoCAD SHX Text

CONT

AutoCAD SHX Text

CONTINUATION

AutoCAD SHX Text

AMERICAN SOCIETY OF SANITARY ENGINEERS

AutoCAD SHX Text

CD

AutoCAD SHX Text

CONDENSATE DRAIN

AutoCAD SHX Text

CB

AutoCAD SHX Text

CATCH BASIN

AutoCAD SHX Text

GD

AutoCAD SHX Text

GUTTER DRAIN

AutoCAD SHX Text

PLUMBING ABBREVIATIONS (NOT ALL SYMBOLS USED)

AutoCAD SHX Text

WCO

AutoCAD SHX Text

WALL CLEAN OUT

AutoCAD SHX Text

SHT

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

RD

AutoCAD SHX Text

ROOF DRAIN

AutoCAD SHX Text

WC

AutoCAD SHX Text

WATER CLOSET

AutoCAD SHX Text

WHA

AutoCAD SHX Text

WATER HAMMER ARRESTOR

AutoCAD SHX Text

ETP

AutoCAD SHX Text

ELECTRONIC TRAP PRIMER

AutoCAD SHX Text

OSD

AutoCAD SHX Text

OPEN SITE DRAIN

AutoCAD SHX Text

TMV

AutoCAD SHX Text

THERMOSTATIC MIXING VALVE

AutoCAD SHX Text

ECO

AutoCAD SHX Text

EXTERIOR CLEAN OUT

AutoCAD SHX Text

ST

AutoCAD SHX Text

STORM

AutoCAD SHX Text (E)

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

MPETP

AutoCAD SHX Text

MINI-PRIME ELECTRONIC TRAP PRIMER

AutoCAD SHX Text

AREA/FLOOR/ROOF DRAIN

AutoCAD SHX Text

AD/FD/RD

AutoCAD SHX Text

VALVE IN RISER

AutoCAD SHX Text

PRESSURE GAUGE

AutoCAD SHX Text

CONCENTRIC REDUCER

AutoCAD SHX Text

ECCENTRIC REDUCER

AutoCAD SHX Text

PIPE CAPPED

AutoCAD SHX Text

PIPE UNION

AutoCAD SHX Text

FCO

AutoCAD SHX Text

CO

AutoCAD SHX Text

WCO

AutoCAD SHX Text

CLEAN OUT AT FLOOR

AutoCAD SHX Text

CLEAN OUT

AutoCAD SHX Text

WALL CLEAN OUT

AutoCAD SHX Text

FCO

AutoCAD SHX Text

CO

AutoCAD SHX Text

WCO

AutoCAD SHX Text

AD/FD/RD

AutoCAD SHX Text

DIA

AutoCAD SHX Text

DIAMETER

AutoCAD SHX Text %%C

AutoCAD SHX Text

WHA

AutoCAD SHX Text

WATER HAMMER ARRESTOR, 'A' DENOTES PDI SIZE

AutoCAD SHX Text 'A'

AutoCAD SHX Text

CO

AutoCAD SHX Text

CO

AutoCAD SHX Text

CLEAN OUT AT BASE OF STACK

AutoCAD SHX Text

SF

AutoCAD SHX Text

SQUARE FOOT

AutoCAD SHX Text

TYP

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

POINT OF CONNECTION (NEW TO OLD)

AutoCAD SHX Text

POINT OF DISCONNECTION

AutoCAD SHX Text

SS

AutoCAD SHX Text

STAINLESS STEEL

AutoCAD SHX Text

AD

AutoCAD SHX Text

AREA DRAIN

AutoCAD SHX Text

ABBREV.

AutoCAD SHX Text

ABBREVIATION

AutoCAD SHX Text

ABA

AutoCAD SHX Text

ARCHITECTURAL BARRIERS ACT

AutoCAD SHX Text

1. ALL PLUMBING AND MEDICAL GAS WORK SHALL CLOSELY FOLLOW THE VA DESIGN MANUALS, PHYSICAL ALL PLUMBING AND MEDICAL GAS WORK SHALL CLOSELY FOLLOW THE VA DESIGN MANUALS, PHYSICAL SECURITY DESIGN MANUAL FOR VA FACILITIES, AND ALL CURRENT APPLICABLE CODES. 2. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL MATERIALS NECESSARY TO COMPLETE SCOPE OF THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL MATERIALS NECESSARY TO COMPLETE SCOPE OF WORK UNLESS OTHERWISE SPECIFIED. 3. INSTALLATION OF PLUMBING PIPING SHALL BE COORDINATED WITH OTHER TRADES WORKS TO AVOID INSTALLATION OF PLUMBING PIPING SHALL BE COORDINATED WITH OTHER TRADES WORKS TO AVOID CONFLICTS. 4. CONTRACTOR SHALL NOT ORDER EQUIPMENT OR BEGIN FABRICATION OF PARTS PRIOR TO SHOP CONTRACTOR SHALL NOT ORDER EQUIPMENT OR BEGIN FABRICATION OF PARTS PRIOR TO SHOP DRAWING APPROVAL. 5. ALL NEW PIPING (WATER, SANITARY, VENT, STORM, MEDICAL GASES, ETC) SHALL MATCH EXISTING SIZES ALL NEW PIPING (WATER, SANITARY, VENT, STORM, MEDICAL GASES, ETC) SHALL MATCH EXISTING SIZES AND TYPES. 6. FIELD VERIFY CONDITIONS BEFORE STARTING CONSTRUCTION AND NOTIFY THE ARCHITECT/ENGINEER FIELD VERIFY CONDITIONS BEFORE STARTING CONSTRUCTION AND NOTIFY THE ARCHITECT/ENGINEER OF DISCREPANCIES WITH THE CONSTRUCTION DOCUMENTS AND/OR POTENTIAL PROBLEMS OBSERVED BEFORE COMMENCING WORK IN AFFECTED AREAS. 7. PIPE PENETRATIONS THROUGH FIRE OR SMOKE PARTITIONS, WALLS, AND/OR FLOORS SHALL BE MADE PIPE PENETRATIONS THROUGH FIRE OR SMOKE PARTITIONS, WALLS, AND/OR FLOORS SHALL BE MADE FIRE AND SMOKE TIGHT. MAINTAIN FIRE RATING OF FLOOR AND WALL ASSEMBLIES IN ACCORDANCE WITH UL SYSTEMS. INSTALL PIPE PENETRATION ASSEMBLIES IN ACCORDANCE WITH UL LISTED MANUFACTURER'S RECOMMENDATIONS. 8. PROVIDE ALL NECESSARY HANGERS FOR SUPPORT OF HORIZONTAL AND VERTICAL PIPING IN PROVIDE ALL NECESSARY HANGERS FOR SUPPORT OF HORIZONTAL AND VERTICAL PIPING IN ACCORDANCE WITH GOOD PRACTICE AND MANUFACTURER'S RECOMMENDATIONS. PROVIDE SLEEVES AND ESCUTCHEONS FOR ALL PIPING PASSING THRU WALLS AND FLOORS. 9. COMPLETE LAYOUT DRAWINGS SHALL BE REQUIRED BY PARAGRAPH, SUBMITTAL. CONSTRUCTION WORK COMPLETE LAYOUT DRAWINGS SHALL BE REQUIRED BY PARAGRAPH, SUBMITTAL. CONSTRUCTION WORK SHALL NOT START ON ANY SYSTEM UNTIL THE LAYOUT DRAWING HAVE BEEN APPROVED BY VA. 10. TEST, BALANCE, STERILIZE AND FLUSH PIPING SYSTEMS. CLEAN ALL EQUIPMENT AND FIXTURES AT TEST, BALANCE, STERILIZE AND FLUSH PIPING SYSTEMS. CLEAN ALL EQUIPMENT AND FIXTURES AT THE COMPLETION OF THE PROJECT. KEEP PREMISES CLEAN DURING CONSTRUCTION. 11. PROVIDE ACCESS DOORS/PANELS AT LOCATION OF VALVES AND OTHER COMPONENTS WHERE PROVIDE ACCESS DOORS/PANELS AT LOCATION OF VALVES AND OTHER COMPONENTS WHERE LOCATED ABOVE HARD CEILINGS OR INSIDE WALLS. 12. ALL SLOPES AND INVERT ELEVATIONS SHALL BE VERIFIED BEFORE ANY PIPING IS INSTALLED IN ALL SLOPES AND INVERT ELEVATIONS SHALL BE VERIFIED BEFORE ANY PIPING IS INSTALLED IN ORDER TO INSURE THAT PROPER SLOPES ARE MAINTAINED. 13. ALL WATER LINES SHALL HAVE SHUT-OFF VALVES AT CONNECTIONS OF FIXTURES AND EQUIPMENT. ALL WATER LINES SHALL HAVE SHUT-OFF VALVES AT CONNECTIONS OF FIXTURES AND EQUIPMENT. PROVIDE DRAIN VALVES AT PIPING LOW POINTS. 14. ALL FIELD OBSERVATION BY CONTRACTOR INCLUDING BUT NOT LIMITED TO ALL FIELD OBSERVATION BY CONTRACTOR INCLUDING BUT NOT LIMITED TO DEAD LEGS AND ABANDONED PIPING TO BE DEMOLISHED AND REMOVED FROM SITE. 15. PROVIDE ALL NECESSARY HANGERS FOR SUPPORT OF HORIZONTAL AND VERTICAL PIPING IN PROVIDE ALL NECESSARY HANGERS FOR SUPPORT OF HORIZONTAL AND VERTICAL PIPING IN ACCORDANCE WITH GOOD PRACTICE AND MANUFACTURER'S RECOMMENDATIONS. PROVIDE SLEEVES AND ESCUTCHEONS FOR ALL PIPING PASSING THRU WALLS AND FLOORS. 16. IN GENERAL, ALL PIPING SHALL BE RUN CONCEALED IN SUSPENDED CEILING AND PIPE SPACES IN GENERAL, ALL PIPING SHALL BE RUN CONCEALED IN SUSPENDED CEILING AND PIPE SPACES PROVIDED UNLESS NOTED OR INDICATED OTHERWISE. 17. REMOVE TRASH AND DEBRIS FROM THE WORK AREA ON A DAILY BASIS. REFER TO SPECIFICATIONS REMOVE TRASH AND DEBRIS FROM THE WORK AREA ON A DAILY BASIS. REFER TO SPECIFICATIONS FOR SPECIFIC REMOVAL AND DISPOSAL REQUIREMENTS. 18. DEAD ENDS SHALL BE PROHIBITED IN THE INSTALLATION OF ANY PART OF THE DRAINAGE SYSTEM DEAD ENDS SHALL BE PROHIBITED IN THE INSTALLATION OF ANY PART OF THE DRAINAGE SYSTEM (EXCEPT FUTURE PROVISIONS SHALL BE CAPPED). 19. PROVIDE MANUFACTURED EXPANSION DEVICE OR FABRICATED EXPANSION LOOP ON ALL PIPING PROVIDE MANUFACTURED EXPANSION DEVICE OR FABRICATED EXPANSION LOOP ON ALL PIPING SYSTEMS CROSSING BUILDING EXPANSION JOINTS. 20. SEE DRAWING SHEET A-001 FOR ADDITIONAL INFORMATION.SEE DRAWING SHEET A-001 FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text

BFF

AutoCAD SHX Text

BELOW FINISHED FLOOR

AutoCAD SHX Text

ETR

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text

INST

AutoCAD SHX Text

INSTALLATION

AutoCAD SHX Text

LDR

AutoCAD SHX Text

LEADER

AutoCAD SHX Text

BFG

AutoCAD SHX Text

BELOW FINISHED GRADE

AutoCAD SHX Text

FM

AutoCAD SHX Text

FORCED MAIN

AutoCAD SHX Text

TW

AutoCAD SHX Text

TEMPERED WATER

AutoCAD SHX Text

BWV

AutoCAD SHX Text

BACKWATER VALVE

AutoCAD SHX Text

PDI

AutoCAD SHX Text

PLUMBING AND DRAINAGE INSTITUTE

A-PD101U

A-PD102U

A-

PD

1U

A-

PD

3U

R

S

U

T

V

W

X

U

2 3 4 5 7 9

CC

DD

Z

AA

BB

Y

EE

HH

12 323028

23 24 2611

EX EX EX EX

EX EX

BB

DD

EE

BB

AA

DD

EX

EX

EX

DD

BB

EX

EX

EX

AA

EX

Z

33 35

Y

V

W

X

Z

AA

U

R

T

S

R

S

U

R

T

DN

RAMP

E

A

S

T t h

R

RAMP DN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

Key Plan

Balance of Work

9/12/2022

SCALE: 1/16" = 1'-0"

8'40 16'

D1

PLAN

NORTH

PARTIAL UNDERGROUND FLOOR

DEMOLITION REFERENCE PLAN

TM KS

PARTIAL UNDERGROUND FLOOR DEMOLITION REFERENCE PLAN

A-PD100U

NOTE:

THE GROUND FLOOR PLAN HAS BEEN SUPERIMPOSED OVER THE

UNDERGROUND FLOOR PLAN FOR SPACIAL REFERENCE

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text Open

AutoCAD SHX Text to Above

AutoCAD SHX Text to Above

AutoCAD SHX Text Open

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

RAMP DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

RAMP UP

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

BLDG 6

SHEET NOTES:

GENERAL NOTES:

DN

RAMP

(E)4"SAN

FROM ABOVE

(E)1" CW UP, BOTTOM

CAP IN CRAWL SPACE

REMOVE ALL ASSOCIATED

CW PIPING UP THROUGH

GROUND FLOOR AND CAP

(NO DEAD LEGS)

(E)4" SAN

(E)4" SAN

(E) 4" SAN

FROM ABOVE

(E)CO

(E)6" SAN PIPE

FROM (E) TRENCH

DRAIN ABOVE

(E)6" SAN

PIPE FROM

(E) TRENCH

DRAIN ABOVE

(E)4" SAN FROM

REST ROOM IN SUPPLY

0213F

(E)2" SAN FROM

SINK ABOVE

(E)4" SAN

FROM WC

(E)4" SAN FROM

SHOWER ABOVE

(E)4" SAN FROM

FD IN EMPTY

GAS CYLINDERS

0210E

(E)2" V UP

4"CAP

TEMPORARILY CAP,

PREPARE FOR NEW

WORK CONNECTION

(E)2" SAN FROM

EWC ABOVE

(E)6" SAN

PIPE FROM

(E)8" SAN

(E)6" SAN

PIPE FROM

CUT PORTION

OF (E) PIPE

AND PREPARE PIPING

FOR NEW CONNECTION

A-PD101U

A-PD102U

A-

PD

1U

A-

PD

3U

(E)4" SAN

PIPE FROM FD

ABOVE

(E)CO

(E)4" SAN

REPLACE DAMAGED PIPE

& BROKEN HANGERS THIS

AREA IN KIND

(E)3"SAN FROM

(E) AREA DRAIN

ABOVE

(E)2" SAN

(E)4" ST PIPE

FROM ABOVE

AA

EX

Z

U

EX

AA

EX

12 323028

22 23 24 2611

EX EX EX EX

EX EX

Y

V

W

X

Z

AA

U

U

V

W

X

U

TM KS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

Key Plan

Balance of Work

9/12/2022

PLAN

NORTH

D1

A-PD101U

PARTIAL UNDERGROUND FLOOR

DEMO PLAN - PART A

PARTIAL UNDERGROUND FLOOR DEMO PLAN - PART A

NOTE:

THE GROUND FLOOR PLAN HAS BEEN SUPERIMPOSED OVER THE

UNDERGROUND FLOOR PLAN FOR SPACIAL REFERENCE

AutoCAD SHX Text

1. SEE SHEET P001 FOR SYMBOLS AND ABBREVIATIONS. SEE SHEET P001 FOR SYMBOLS AND ABBREVIATIONS. 2. SEE P501 SERIES FOR PLUMBING DETAILS. SEE P501 SERIES FOR PLUMBING DETAILS. 3. SEE P700 SERIES FOR PLUMBING SCHEDULES. SEE P700 SERIES FOR PLUMBING SCHEDULES. 4. ALL DAMAGE TO FLOOR SURFACES AS A RESULT OF THIS WORK, TO BE PATCHED TO MATCH ADJACENT SURFACES. ALL DAMAGE TO FLOOR SURFACES AS A RESULT OF THIS WORK, TO BE PATCHED TO MATCH ADJACENT SURFACES. 5. WHERE APPLICABLE, REFER TO DRAWING LS-001 FOR FIRE AND SMOKE BARRIER WALL LEGEND. WHERE APPLICABLE, REFER TO DRAWING LS-001 FOR FIRE AND SMOKE BARRIER WALL LEGEND. 6. REFER TO ARCHITECTURAL SHEET A-AD101 & A-AD102 FOR LOCATIONS OF FLOOR SAW CUTTING. REFER TO REFER TO ARCHITECTURAL SHEET A-AD101 & A-AD102 FOR LOCATIONS OF FLOOR SAW CUTTING. REFER TO DETAIL A7 ON SHEET A-AE503 UNDERSLAB PIPING DETAIL. DETAIL A7 ON SHEET A-AE503 UNDERSLAB PIPING DETAIL.

AutoCAD SHX Text

1. AS-BUILT DRAWINGS ARE NOT AVAILABLE TO POSITIVELY IDENTIFY ALL EXISTING CONDITIONS. CONTRACTOR MUST AS-BUILT DRAWINGS ARE NOT AVAILABLE TO POSITIVELY IDENTIFY ALL EXISTING CONDITIONS. CONTRACTOR MUST FIELD VERIFY ALL PIPING LOCATED ABOVE CEILINGS, IN WALL CAVITIES AND BELOW FINISHED FLOORS AS PER SCOPE OF WORK WITH DUCTWORK, ELECTRICAL CONDUITS ETC., IN EVERY ROOM WITHIN THE SCOPE OF WORK AND IDENTIFY ACTIVE VERSUS INACTIVE COMPONENTS. CONTRACTOR IS RESPONSIBLE FOR COMPLETE DEMO OF PIPING, FIXTURES, CARRIERS AND ASSOCIATED APPURTENANCES, OR RELOCATION AS REQUIRED TO ACCOMMODATE WITH OTHER DISCIPLINES ASSOCIATED WITH THIS PROJECT. 2. PIPING TO BE DEMOLISHED MUST BE REMOVED COMPLETELY (INCLUDING ASSOCIATED APPURTENANCES BACK TO PIPING TO BE DEMOLISHED MUST BE REMOVED COMPLETELY (INCLUDING ASSOCIATED APPURTENANCES BACK TO IT'S SOURCE AS CLOSE AS POSSIBLE TO AVOID DEAD LEGS AND CAPPED HW/CW, PLUGGED SANITARY AND VENT TO BE PLUGGED OR CAPPED AS CLOSE AS POSSIBLE TO MAIN OR BRANCH PIPE. 3. GROUND FLOOR WALLS AND ROOM NAMES ARE SHOWN FOR SPACIAL ORIENTATION AND ARE FOR REFERENCE GROUND FLOOR WALLS AND ROOM NAMES ARE SHOWN FOR SPACIAL ORIENTATION AND ARE FOR REFERENCE ONLY. ALL WORK SHOWN ON THE UNDERGROUND FLOOR PLAN IS LOCATED BELOW THE GROUND FLOOR LEVEL. 4. CONTRACTOR SHALL PROVIDE A TEMPORARY MEANS OF STORM DRAINAGE DURING RENOVATION.CONTRACTOR SHALL PROVIDE A TEMPORARY MEANS OF STORM DRAINAGE DURING RENOVATION.

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text (E)10"

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text (E)5"

AutoCAD SHX Text (E)4"

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

(E)4"SAN FROM ABOVE

AutoCAD SHX Text

(E)4"SAN

AutoCAD SHX Text

(E)3"SAN FROM (E)FD ABOVEFD ABOVE ABOVE

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

(E)4"SAN

AutoCAD SHX Text

(E)4"SAN FROM ABOVE

AutoCAD SHX Text

(E)4"SAN

AutoCAD SHX Text

CO

AutoCAD SHX Text

(E)6"SAN

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

(E)5"SAN

AutoCAD SHX Text

(E)8"SAN

AutoCAD SHX Text

(E)5" SAN PIPE FROM ABOVE

AutoCAD SHX Text

(E)SUMP PUMP

AutoCAD SHX Text

(E)2"CAP

AutoCAD SHX Text

(E)4"SAN

AutoCAD SHX Text

(E)4"SAN FROM ABOVE

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text Z/28

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text Z/30

AutoCAD SHX Text

(E)4" PIPE UP

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

UP TO 4"FDFD

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)8"SAN

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text Z/26

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text Z/28

AutoCAD SHX Text

AA/28

AutoCAD SHX Text

AA/30

AutoCAD SHX Text

AA/24

AutoCAD SHX Text (E)4"

AutoCAD SHX Text (E)2"

AutoCAD SHX Text

(E) 5"SAN FROM ABOVE

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text (E)6"

AutoCAD SHX Text 6"

AutoCAD SHX Text (E)4"

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text (E)4"

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

TUNNEL WALL BFF

AutoCAD SHX Text

(E)4"SAN

AutoCAD SHX Text

(E)3"SAN UP TO (E)FDFD

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text (E)10"

AutoCAD SHX Text

WCO

AutoCAD SHX Text

SAN

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text 4"

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text (E)4"

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text (E)5"

AutoCAD SHX Text (E)6"

AutoCAD SHX Text

(E) PIPE

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)5" PIPE UP

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)3" PIPE UP

AutoCAD SHX Text

(E)2" PIPE UP

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text (E)2"

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text (E)6"

AutoCAD SHX Text (E)4"

AutoCAD SHX Text (E)5"

AutoCAD SHX Text

(E)5"SAN

AutoCAD SHX Text

(E)4" SAN PIPE FROM ABOVE

AutoCAD SHX Text

(E)4"SAN

AutoCAD SHX Text

(E)4"SAN

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E) PIPE

AutoCAD SHX Text

(E)3"SAN

AutoCAD SHX Text

(E)4"SAN

AutoCAD SHX Text

(E)4"SAN FROM ABOVE

AutoCAD SHX Text

(E)4"PD

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

FORMER GENERATOR RM

AutoCAD SHX Text 0272N

AutoCAD SHX Text

SPS RECEIVING

AutoCAD SHX Text 0263N

AutoCAD SHX Text

SPS

AutoCAD SHX Text 0264N

AutoCAD SHX Text

SUPPLY STORAGE

AutoCAD SHX Text 0253N

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 0253E

AutoCAD SHX Text

EQUIPMENT STOR

AutoCAD SHX Text 0252E

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0271N

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text 0270N

AutoCAD SHX Text

FANS

AutoCAD SHX Text 0269N

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 0262N

AutoCAD SHX Text

EMS SUPER

AutoCAD SHX Text 0255N

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text 0244N

AutoCAD SHX Text

ELEC RM

AutoCAD SHX Text 0247N

AutoCAD SHX Text

LINEN CHUTE RM

AutoCAD SHX Text 0253E

AutoCAD SHX Text

MAIN ELECTRIC-BUILDING 1

AutoCAD SHX Text 0242N

AutoCAD SHX Text

ELEC CL

AutoCAD SHX Text

MATERIAL OFFICE

AutoCAD SHX Text 0215E

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0243N

AutoCAD SHX Text

IT ROOM

AutoCAD SHX Text 0211E

AutoCAD SHX Text

EMPTY GAS CYLINDERS

AutoCAD SHX Text 0210E

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 0212E

AutoCAD SHX Text

SERVICE ENTRY

AutoCAD SHX Text 0211E

AutoCAD SHX Text

COMP GAS

AutoCAD SHX Text

AutoCAD SHX Text

NON FLAM GAS

AutoCAD SHX Text

AutoCAD SHX Text

EQUIPMENT STORAGE

AutoCAD SHX Text 0203E

AutoCAD SHX Text

S P D WAREHOUSE

AutoCAD SHX Text 0250E

AutoCAD SHX Text

EMS EQUIPMENT RM

AutoCAD SHX Text 0251E

AutoCAD SHX Text

LOADING DOCK

AutoCAD SHX Text

AutoCAD SHX Text

GOOD RECEIVING

AutoCAD SHX Text 0214E

AutoCAD SHX Text

SUPPLY

AutoCAD SHX Text 0213E

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0242N

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0241N

AutoCAD SHX Text

STAIRWELL

AutoCAD SHX Text 0254N

AutoCAD SHX Text

EQUIPMENT HOLDING

AutoCAD SHX Text

0230AE

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text G245N

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

0264AN

AutoCAD SHX Text

(E)4"SAN FROM ABOVE

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text (E)4"

AutoCAD SHX Text

CRAWL SPACE WALL BFF

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

AutoCAD SHX Text

BLDG 6

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

16'

DEMOLITION NOTES:

RAMP DN

3"

(E)CO

(E)10" SAN

3" SAN PIPE UP

TO BATHROOM IN

FOOD RECEIVING 0218E

SAN PIPE UP TO

SINK IN INGREDIENT

CONTROL 022116E

(E)3" SAN

FROM FD

(E)3" SAN

(E)3" SAN

PIPE UP

(E)2" ST PIPE

FROM RD ABOVE

TEMPORARILY CAP,

PREPARE FOR NEW

WORK CONNECTION

COORDINATE WITH LIMIT

OF WORK PACKAGE "C"

FOR WORK IN THIS AREA

SAN PIPE FROM

3-COMP SINK

DRAIN ABOVE

SAN PIPE

FROM FD

ABOVE

SAN PIPE

FROM FD

ABOVE

SAN PIPE

FROM FD ABOVE

(E)SAN

(E)SAN

(E)3"

(E)3" SAN

(E)6" SAN

PIPE FROM

ABOVE

TEMPORARILY CAP,

PREPARE FOR NEW

WORK CONNECTION

(E)6" SAN

PIPE FROM

ABOVE

CAP PIPE

TEMPORARILY

CAP PIPE

TEMPORARILY

A-PD101U

A-PD102U

12 323028

22 23 24 2611

EX EX

EX EX

EX EX

BB

DD

EX

EX

EX

BB

DD

EE

33 35

EE

DD

BB

EX

EX

EX

AA

EX

CC

DD

AA

BB

EE

HH

TM KS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

Key Plan

Balance of Work

9/12/2022

PLAN

NORTH

D1

A-PD102U

PARTIAL UNDERGROUND FLOOR

DEMO PLAN - PART B

PARTIAL UNDERGROUND FLOOR DEMO PLAN - PART B

NOTE:

THE GROUND FLOOR PLAN HAS BEEN SUPERIMPOSED OVER THE

UNDERGROUND FLOOR PLAN FOR SPACIAL REFERENCE

AutoCAD SHX Text

1. SEE SHEET P001 FOR SYMBOLS AND ABBREVIATIONS. SEE SHEET P001 FOR SYMBOLS AND ABBREVIATIONS. 2. SEE P501 SERIES FOR PLUMBING DETAILS. SEE P501 SERIES FOR PLUMBING DETAILS. 3. SEE P700 SERIES FOR PLUMBING SCHEDULES. SEE P700 SERIES FOR PLUMBING SCHEDULES. 4. ALL DAMAGE TO FLOOR SURFACES AS A RESULT OF THIS WORK, TO BE PATCHED TO MATCH ADJACENT SURFACES. ALL DAMAGE TO FLOOR SURFACES AS A RESULT OF THIS WORK, TO BE PATCHED TO MATCH ADJACENT SURFACES. 5. WHERE APPLICABLE, REFER TO DRAWING LS-001 FOR FIRE AND SMOKE BARRIER WALL LEGEND. WHERE APPLICABLE, REFER TO DRAWING LS-001 FOR FIRE AND SMOKE BARRIER WALL LEGEND. 6. REFER TO ARCHITECTURAL SHEET A-AD101 & A-AD102 FOR LOCATIONS OF FLOOR SAW CUTTING. REFER TO REFER TO ARCHITECTURAL SHEET A-AD101 & A-AD102 FOR LOCATIONS OF FLOOR SAW CUTTING. REFER TO DETAIL A7 ON SHEET A-AE503 UNDERSLAB PIPING DETAIL. DETAIL A7 ON SHEET A-AE503 UNDERSLAB PIPING DETAIL.

AutoCAD SHX Text

1. AS-BUILT DRAWINGS ARE NOT AVAILABLE TO POSITIVELY IDENTIFY ALL EXISTING CONDITIONS. CONTRACTOR MUST AS-BUILT DRAWINGS ARE NOT AVAILABLE TO POSITIVELY IDENTIFY ALL EXISTING CONDITIONS. CONTRACTOR MUST FIELD VERIFY ALL PIPING LOCATED ABOVE CEILINGS, IN WALL CAVITIES AND BELOW FINISHED FLOORS AS PER SCOPE OF WORK WITH DUCTWORK, ELECTRICAL CONDUITS ETC., IN EVERY ROOM WITHIN THE SCOPE OF WORK AND IDENTIFY ACTIVE VERSUS INACTIVE COMPONENTS. CONTRACTOR IS RESPONSIBLE FOR COMPLETE DEMO OF PIPING, FIXTURES, CARRIERS AND ASSOCIATED APPURTENANCES, OR RELOCATION AS REQUIRED TO ACCOMMODATE WITH OTHER DISCIPLINES ASSOCIATED WITH THIS PROJECT. 2. PIPING TO BE DEMOLISHED MUST BE REMOVED COMPLETELY (INCLUDING ASSOCIATED APPURTENANCES BACK TO PIPING TO BE DEMOLISHED MUST BE REMOVED COMPLETELY (INCLUDING ASSOCIATED APPURTENANCES BACK TO IT'S SOURCE AS CLOSE AS POSSIBLE TO AVOID DEAD LEGS AND CAPPED HW/CW, PLUGGED SANITARY AND VENT TO BE PLUGGED OR CAPPED AS CLOSE AS POSSIBLE TO MAIN OR BRANCH PIPE. 3. GROUND FLOOR WALLS AND ROOM NAMES ARE SHOWN FOR SPACIAL ORIENTATION AND ARE FOR REFERENCE GROUND FLOOR WALLS AND ROOM NAMES ARE SHOWN FOR SPACIAL ORIENTATION AND ARE FOR REFERENCE ONLY. ALL WORK SHOWN ON THE UNDERGROUND FLOOR PLAN IS LOCATED BELOW THE GROUND FLOOR LEVEL. 4. CONTRACTOR SHALL PROVIDE A TEMPORARY MEANS OF STORM DRAINAGE DURING RENOVATION.CONTRACTOR SHALL PROVIDE A TEMPORARY MEANS OF STORM DRAINAGE DURING RENOVATION.

AutoCAD SHX Text

STAIR

AutoCAD SHX Text 1-1

AutoCAD SHX Text

SE #13

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

DOCK LEVELER

AutoCAD SHX Text #2

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

DOCK LEVELER

AutoCAD SHX Text #3

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

RAMP UP

AutoCAD SHX Text

ST

AutoCAD SHX Text

AutoCAD SHX Text

IE+4.41

AutoCAD SHX Text

IE+4.16

AutoCAD SHX Text

IE+4.31

AutoCAD SHX Text

IE+4.06

AutoCAD SHX Text

(E)HOUSE TRAP

AutoCAD SHX Text

(E)HOUSE TRAP

AutoCAD SHX Text (E)12"

AutoCAD SHX Text (E)10"

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text (E)10"

AutoCAD SHX Text (E)6"

AutoCAD SHX Text (E)6"

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text (E)10"

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)4" ST UP

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

AA/28

AutoCAD SHX Text

AA/30

AutoCAD SHX Text

AB/30

AutoCAD SHX Text

AB/32

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

(E)5" UP

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text

CO

AutoCAD SHX Text

CO

AutoCAD SHX Text (E)4"

AutoCAD SHX Text 10"

AutoCAD SHX Text

(E)2"ST

AutoCAD SHX Text

(E)2"ST

AutoCAD SHX Text

(E)CO

AutoCAD SHX Text 6"

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)6"

AutoCAD SHX Text (E)10"

AutoCAD SHX Text

RISER

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

WCO

AutoCAD SHX Text

(E)3" SAN PIPE FROM FDFD

AutoCAD SHX Text

CO

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text (E)3"

AutoCAD SHX Text

(E)3"SAN

AutoCAD SHX Text

(E)4" ST PIPE FROM ABOVE

AutoCAD SHX Text

(E)ST

AutoCAD SHX Text

(E)4"ST

AutoCAD SHX Text

(E)6" ST UP

AutoCAD SHX Text (E)6"

AutoCAD SHX Text (E)5"

AutoCAD SHX Text

(E)5" ST UP

AutoCAD SHX Text

(E)4" ST UP

AutoCAD SHX Text

(E)4"ST

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text (E)10"

AutoCAD SHX Text

(E) PIPE

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text (E)5"

AutoCAD SHX Text (E)4"

AutoCAD SHX Text

(E) PIPE

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E) PIPE

AutoCAD SHX Text

(E) PIPE

AutoCAD SHX Text

(E) PIPE

AutoCAD SHX Text

(E) PIPE

AutoCAD SHX Text

(E) PIPE

AutoCAD SHX Text

(E)2"ST

AutoCAD SHX Text 3"

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

CANTEEN STORAGE

AutoCAD SHX Text

0252EA

AutoCAD SHX Text

VAULT 2

AutoCAD SHX Text 0253E

AutoCAD SHX Text

PHARMACY DRUG CACHE

AutoCAD SHX Text 0255E

AutoCAD SHX Text

VAULT 2

AutoCAD SHX Text 0253E

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0257E

AutoCAD SHX Text

REFRIGERATOR

AutoCAD SHX Text 0253F

AutoCAD SHX Text

KITCHEN

AutoCAD SHX Text 0233E

AutoCAD SHX Text

FOOD RECEIVING

AutoCAD SHX Text 0218E

AutoCAD SHX Text

INGREDIENT CONTROL

AutoCAD SHX Text 0216E

AutoCAD SHX Text

IRM STORAGE

AutoCAD SHX Text

0252EB

AutoCAD SHX Text

(E)HOUSE TRAP

AutoCAD SHX Text

(E)4" SAN PIPE FROM ABOVE

AutoCAD SHX Text 4"

AutoCAD SHX Text

TUNNEL WALL BFF

AutoCAD SHX Text

TUNNEL WALL BFF

AutoCAD SHX Text

CRAWL SPACE WALL BFF

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

AutoCAD SHX Text

BLDG 6

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

DEMOLITION NOTES:

(E)1-1/2" SAN UP

TO SINK

(E)2" SAN FROM

DEMOLISHED SINK IN

RADIOACTIVE RM. G206S

(E)2" SAN

CUT PORTION OF (E) PIPE

AND PREPARE PIPING FOR

NEW CONNECTION

A-

PD

1U

A-

PD

3U

U

V

W

X

U

2 3 4 5 7 9

Z

Y

TM KS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

Key Plan

Balance of Work

9/12/2022

PLAN

NORTH

PARTIAL UNDERGROUND FLOOR DEMO PLAN - PART C

D3

A-PD103U

PARTIAL UNDERGROUND FLOOR

DEMO PLAN - PART C

NOTE:

THE GROUND FLOOR PLAN HAS BEEN SUPERIMPOSED OVER THE

UNDERGROUND FLOOR PLAN FOR SPACIAL REFERENCE

AutoCAD SHX Text

1. SEE SHEET P001 FOR SYMBOLS AND ABBREVIATIONS. SEE SHEET P001 FOR SYMBOLS AND ABBREVIATIONS. 2. SEE P501 SERIES FOR PLUMBING DETAILS. SEE P501 SERIES FOR PLUMBING DETAILS. 3. SEE P700 SERIES FOR PLUMBING SCHEDULES. SEE P700 SERIES FOR PLUMBING SCHEDULES. 4. ALL DAMAGE TO FLOOR SURFACES AS A RESULT OF THIS WORK, TO BE PATCHED TO MATCH ADJACENT SURFACES. ALL DAMAGE TO FLOOR SURFACES AS A RESULT OF THIS WORK, TO BE PATCHED TO MATCH ADJACENT SURFACES. 5. WHERE APPLICABLE, REFER TO DRAWING LS-001 FOR FIRE AND SMOKE BARRIER WALL LEGEND. WHERE APPLICABLE, REFER TO DRAWING LS-001 FOR FIRE AND SMOKE BARRIER WALL LEGEND. 6. REFER TO ARCHITECTURAL SHEET A-AD101 & A-AD102 FOR LOCATIONS OF FLOOR SAW CUTTING. REFER TO REFER TO ARCHITECTURAL SHEET A-AD101 & A-AD102 FOR LOCATIONS OF FLOOR SAW CUTTING. REFER TO DETAIL A7 ON SHEET A-AE503 UNDERSLAB PIPING DETAIL. DETAIL A7 ON SHEET A-AE503 UNDERSLAB PIPING DETAIL.

AutoCAD SHX Text

1. AS-BUILT DRAWINGS ARE NOT AVAILABLE TO POSITIVELY IDENTIFY ALL EXISTING CONDITIONS. CONTRACTOR MUST AS-BUILT DRAWINGS ARE NOT AVAILABLE TO POSITIVELY IDENTIFY ALL EXISTING CONDITIONS. CONTRACTOR MUST FIELD VERIFY ALL PIPING LOCATED ABOVE CEILINGS, IN WALL CAVITIES AND BELOW FINISHED FLOORS AS PER SCOPE OF WORK WITH DUCTWORK, ELECTRICAL CONDUITS ETC., IN EVERY ROOM WITHIN THE SCOPE OF WORK AND IDENTIFY ACTIVE VERSUS INACTIVE COMPONENTS. CONTRACTOR IS RESPONSIBLE FOR COMPLETE DEMO OF PIPING, FIXTURES, CARRIERS AND ASSOCIATED APPURTENANCES, OR RELOCATION AS REQUIRED TO ACCOMMODATE WITH OTHER DISCIPLINES ASSOCIATED WITH THIS PROJECT. 2. PIPING TO BE DEMOLISHED MUST BE REMOVED COMPLETELY (INCLUDING ASSOCIATED APPURTENANCES BACK TO PIPING TO BE DEMOLISHED MUST BE REMOVED COMPLETELY (INCLUDING ASSOCIATED APPURTENANCES BACK TO IT'S SOURCE AS CLOSE AS POSSIBLE TO AVOID DEAD LEGS AND CAPPED HW/CW, PLUGGED SANITARY AND VENT TO BE PLUGGED OR CAPPED AS CLOSE AS POSSIBLE TO MAIN OR BRANCH PIPE. 3. GROUND FLOOR WALLS AND ROOM NAMES ARE SHOWN FOR SPACIAL ORIENTATION AND ARE FOR REFERENCE GROUND FLOOR WALLS AND ROOM NAMES ARE SHOWN FOR SPACIAL ORIENTATION AND ARE FOR REFERENCE ONLY. ALL WORK SHOWN ON THE UNDERGROUND FLOOR PLAN IS LOCATED BELOW THE GROUND FLOOR LEVEL. 4. CONTRACTOR SHALL PROVIDE A TEMPORARY MEANS OF STORM DRAINAGE DURING RENOVATION.CONTRACTOR SHALL PROVIDE A TEMPORARY MEANS OF STORM DRAINAGE DURING RENOVATION.

AutoCAD SHX Text

ELEC

AutoCAD SHX Text 0165S

AutoCAD SHX Text

LOCKERS

AutoCAD SHX Text 0168S

AutoCAD SHX Text

ELEC

AutoCAD SHX Text 0167S

AutoCAD SHX Text G191S

AutoCAD SHX Text

SECURITY RM.

AutoCAD SHX Text 0202S

AutoCAD SHX Text

SPECIMEN STORAGE

AutoCAD SHX Text 0171S

AutoCAD SHX Text 0169S

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text 0166S

AutoCAD SHX Text

SHR

AutoCAD SHX Text G193S

AutoCAD SHX Text

TOILET

AutoCAD SHX Text G190S

AutoCAD SHX Text

VEST

AutoCAD SHX Text 0199S

AutoCAD SHX Text

ELEV.MACH. RM.

AutoCAD SHX Text

0203AS

AutoCAD SHX Text

STAFF TOILET

AutoCAD SHX Text

0202BS

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0202S

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

0202AS

AutoCAD SHX Text

IT (TR-D)

AutoCAD SHX Text

0209SA

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text 0184S

AutoCAD SHX Text

PUMPS

AutoCAD SHX Text 0166S

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

STAIRS #3

AutoCAD SHX Text G2189S

AutoCAD SHX Text Open

AutoCAD SHX Text to Above

AutoCAD SHX Text to Above

AutoCAD SHX Text Open

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

RAMP DN

AutoCAD SHX Text

SECURITY CONTROL

AutoCAD SHX Text

RM. (POST 7)

AutoCAD SHX Text 0200S

AutoCAD SHX Text

CO

AutoCAD SHX Text

(E)2" SAN

AutoCAD SHX Text

UP TO PAINT SHOP SINK

AutoCAD SHX Text (E)4"

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)4" SAN

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

(E)SAN

AutoCAD SHX Text

RAD WASTE

AutoCAD SHX Text 0253G

AutoCAD SHX Text

STAFF CLOTHING RM

AutoCAD SHX Text G201S

AutoCAD SHX Text

LOCKER RM

AutoCAD SHX Text

G204BS

AutoCAD SHX Text

REGULATED MEDICAL WASTE

AutoCAD SHX Text G204S

AutoCAD SHX Text

INTERIM STORAGE

AutoCAD SHX Text G205S

AutoCAD SHX Text

RADIOACTIVE GAS METER

AutoCAD SHX Text

G204AS

AutoCAD SHX Text

PAINT SHOP

AutoCAD SHX Text 0203S

AutoCAD SHX Text

PAINT SHOP

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text 0203S

AutoCAD SHX Text

RADIOACTIVE RM

AutoCAD SHX Text G206S

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

AutoCAD SHX Text

BLDG 6

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

DN

BUILDING 1

RAMP DN

B

U

I

L

D

I

N

G o

S

U

T

V

W

X

U

2 3 4 5 7 9

CC

DD

Z

AA

BB

Y

EE

HH

12 323028

22 23 24 2611

EX EX EX EX

EX EX

BB

DD

EE

BB

AA

DD

EX

EX

EX

DD

BB

EX

EX

EX

AA

EX

Z

33 35

Y

V

W

X

Z

AA

U

R

T

S

R

S

U

R

T

A-PD101

A-PD102

A-

PD

A-

PD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

Key Plan

Balance of Work

9/12/2022

SCALE: 1/16" = 1'-0"

8'4'0 16'

D1

PLAN

NORTH

A-PD100

PARTIAL GROUND FLOOR

DEMOLITION REFERENCE PLAN

TM KS

PARTIAL GROUND FLOOR DEMOLITION REFERENCE PLAN

AutoCAD SHX Text

CSSSD

AutoCAD SHX Text G580

AutoCAD SHX Text

ELEC

AutoCAD SHX Text 0165S

AutoCAD SHX Text

LOCKERS

AutoCAD SHX Text 0168S

AutoCAD SHX Text

CHAPLAIN STORAGE

AutoCAD SHX Text 0173S

AutoCAD SHX Text

ELEC

AutoCAD SHX Text 0167S

AutoCAD SHX Text G191S

AutoCAD SHX Text

0148AS

AutoCAD SHX Text

SECURITY RM.

AutoCAD SHX Text 0202S

AutoCAD SHX Text

CLOSET

AutoCAD SHX Text 0147S

AutoCAD SHX Text

NAVE

AutoCAD SHX Text 0153S

AutoCAD SHX Text

SPECIMEN CLOS

AutoCAD SHX Text 0170S

AutoCAD SHX Text

SPECIMEN STORAGE

AutoCAD SHX Text 0171S

AutoCAD SHX Text

AUTOPSY

AutoCAD SHX Text 0169S

AutoCAD SHX Text

REFR. MORTUARY

AutoCAD SHX Text 0168S

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

VEST

AutoCAD SHX Text 0166S

AutoCAD SHX Text

SHR

AutoCAD SHX Text G193S

AutoCAD SHX Text

TOILET

AutoCAD SHX Text G190S

AutoCAD SHX Text

VEST

AutoCAD SHX Text 0199S

AutoCAD SHX Text

CLERGY

AutoCAD SHX Text 0163S

AutoCAD SHX Text

ALTAR

AutoCAD SHX Text 0162S

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 0161S

AutoCAD SHX Text

ELEV.MACH. RM.

AutoCAD SHX Text

0203AS

AutoCAD SHX Text

STAFF TOILET

AutoCAD SHX Text

0202BS

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0202S

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

0202AS

AutoCAD SHX Text

CANTEEN STORAGE

AutoCAD SHX Text

0252EA

AutoCAD SHX Text

IRM STORAGE

AutoCAD SHX Text

0252EB

AutoCAD SHX Text

VAULT 2

AutoCAD SHX Text 0253E

AutoCAD SHX Text

PHARMACY DRUG CACHE

AutoCAD SHX Text 0255E

AutoCAD SHX Text

VAULT 2

AutoCAD SHX Text 0253E

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0257E

AutoCAD SHX Text

FORMER GENERATOR RM

AutoCAD SHX Text 0272N

AutoCAD SHX Text

SPS RECEIVING

AutoCAD SHX Text 0263N

AutoCAD SHX Text

SPS

AutoCAD SHX Text 0264N

AutoCAD SHX Text

SUPPLY STORAGE

AutoCAD SHX Text 0253N

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 0253E

AutoCAD SHX Text

EQUIPMENT STOR

AutoCAD SHX Text 0252E

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0271N

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text 0270N

AutoCAD SHX Text

FANS

AutoCAD SHX Text 0269N

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 0262N

AutoCAD SHX Text

STAIR

AutoCAD SHX Text 1-2

AutoCAD SHX Text

EMS SUPER

AutoCAD SHX Text 0255N

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text 0244N

AutoCAD SHX Text

ELEC RM

AutoCAD SHX Text 0247N

AutoCAD SHX Text

LINEN CHUTE RM

AutoCAD SHX Text 0253E

AutoCAD SHX Text

MAIN ELECTRIC-BUILDING 1

AutoCAD SHX Text 0242N

AutoCAD SHX Text

ELEC CL

AutoCAD SHX Text

REFRIGERATOR

AutoCAD SHX Text 0253F

AutoCAD SHX Text

KITCHEN

AutoCAD SHX Text 0233E

AutoCAD SHX Text

FOOD RECEIVING

AutoCAD SHX Text 0218E

AutoCAD SHX Text

INGREDIENT CONTROL

AutoCAD SHX Text 0216E

AutoCAD SHX Text

MATERIAL OFFICE

AutoCAD SHX Text 0215E

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0243N

AutoCAD SHX Text

IT ROOM

AutoCAD SHX Text 0211E

AutoCAD SHX Text

EMPTY GAS CYLINDERS

AutoCAD SHX Text 0210E

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 0212E

AutoCAD SHX Text

SERVICE ENTRY

AutoCAD SHX Text 0211E

AutoCAD SHX Text

COMP GAS

AutoCAD SHX Text

AutoCAD SHX Text

NON FLAM GAS

AutoCAD SHX Text

AutoCAD SHX Text

EQUIPMENT STORAGE

AutoCAD SHX Text 0203E

AutoCAD SHX Text

S P D WAREHOUSE

AutoCAD SHX Text 0250E

AutoCAD SHX Text

EMS EQUIPMENT RM

AutoCAD SHX Text 0251E

AutoCAD SHX Text

LOADING DOCK

AutoCAD SHX Text

AutoCAD SHX Text

GOOD RECEIVING

AutoCAD SHX Text 0214E

AutoCAD SHX Text

SUPPLY

AutoCAD SHX Text 0213E

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0242N

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 0241N

AutoCAD SHX Text

STAIRWELL

AutoCAD SHX Text 0254N

AutoCAD SHX Text G587

AutoCAD SHX Text G588

AutoCAD SHX Text

PLUMBING EQUIP RM

AutoCAD SHX Text G583

AutoCAD SHX Text

SECURE STORAGE

AutoCAD SHX Text G586

AutoCAD SHX Text

CSSSD STAFF AREA

AutoCAD SHX Text G582

AutoCAD SHX Text G596

AutoCAD SHX Text

VENDOR LOANER

AutoCAD SHX Text G589

AutoCAD SHX Text

BREAKDOWN

AutoCAD SHX Text G590

AutoCAD SHX Text

EQUIP HOLDING / DISPATCH

AutoCAD SHX Text G595

AutoCAD SHX Text

SOILED RECEIVING

AutoCAD SHX Text G591

AutoCAD SHX Text

MECH RM

AutoCAD SHX Text G703

AutoCAD SHX Text

JAN.

AutoCAD SHX Text G598

AutoCAD SHX Text

KITCHENETTE

AutoCAD SHX Text 0142C

AutoCAD SHX Text G001W

AutoCAD SHX Text

MALE TOILET

AutoCAD SHX Text G382

AutoCAD SHX Text

SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

ELEV LOBBY

AutoCAD SHX Text G001

AutoCAD SHX Text G003

AutoCAD SHX Text

CLOSET

AutoCAD SHX Text G004

AutoCAD SHX Text

IT (TR-D)

AutoCAD SHX Text

0209SA

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text 0209S

AutoCAD SHX Text

RADIOACTIVE RM

AutoCAD SHX Text G206S

AutoCAD SHX Text

RAD WASTE

AutoCAD SHX Text 0253G

AutoCAD SHX Text

STAFF CLOTHING RM

AutoCAD SHX Text G201S

AutoCAD SHX Text

LOCKER RM

AutoCAD SHX Text

G204BS

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text 0184S

AutoCAD SHX Text

REGULATED MEDICAL WASTE

AutoCAD SHX Text G204S

AutoCAD SHX Text

INTERIM STORAGE

AutoCAD SHX Text G205S

AutoCAD SHX Text

RADIOACTIVE GAS METER

AutoCAD SHX Text

G204AS

AutoCAD SHX Text

PAINT SHOP

AutoCAD SHX Text 0203S

AutoCAD SHX Text

PAINT SHOP

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text 0203S

AutoCAD SHX Text

PUMPS

AutoCAD SHX Text 0166S

AutoCAD SHX Text

PUMP ROOM

AutoCAD SHX Text 0175S

AutoCAD SHX Text

FIRE COMMAND / ATS SWITCH

AutoCAD SHX Text 0273N

AutoCAD SHX Text

EQUIPMENT HOLDING

AutoCAD SHX Text

0230AE

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text G245N

AutoCAD SHX Text

STAIR

AutoCAD SHX Text 1-1

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

PE #1

AutoCAD SHX Text

PE #2

AutoCAD SHX Text

PE #3

AutoCAD SHX Text

PE #4

AutoCAD SHX Text

PE #5

AutoCAD SHX Text

PE #6

AutoCAD SHX Text

PE #7

AutoCAD SHX Text

PE #8

AutoCAD SHX Text

SE #12

AutoCAD SHX Text

SE #11

AutoCAD SHX Text

SE #10

AutoCAD SHX Text

SE #9

AutoCAD SHX Text

SE #13

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

STAIRS #3

AutoCAD SHX Text G2189S

AutoCAD SHX Text Open

AutoCAD SHX Text to Above

AutoCAD SHX Text to Above

AutoCAD SHX Text Open

AutoCAD SHX Text

DN

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

DOCK LEVELER

AutoCAD SHX Text #1

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

DOCK LEVELER

AutoCAD SHX Text #2

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

DOCK LEVELER

AutoCAD SHX Text #3

AutoCAD SHX Text

DN

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

0264AN

AutoCAD SHX Text

CLOSET

AutoCAD SHX Text

0163SA

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 0166S

AutoCAD SHX Text

EMBALMING

AutoCAD SHX Text 0167S

AutoCAD SHX Text

UP

AutoCAD SHX Text

RAMP DN

AutoCAD SHX Text

SECURITY CONTROL

AutoCAD SHX Text

RM. (POST 7)

AutoCAD SHX Text 0200S

AutoCAD SHX Text

REST RM

AutoCAD SHX Text 0213F

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

RAMP UP

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

1. DISCONNECT AND REMOVE PLUMBING FIXTURE AND ALL ASSOCIATED PIPING. REMOVE AND CAP EACH HOT AND

COLD WATER PIPE AT ITS MAIN OR BRANCH WITH NO DEAD LEGS ABOVE CEILING OR BELOW FINISHED FLOOR.

2. DISCONNECT AND REMOVE WASTE AND VENT PIPING BACK TO THEIR RESPECTIVE MAIN OR BRANCH ABOVE CEILING

OR BFF, AND PLUG OR ADD CLEAN OUT AIR TIGHT. REMOVE FIXTURE, FIXTURE SUPPORTS AND TRIM.

3. REMOVE (E)FD AND CAP PIPE WASTE AIR TIGHT BFF. PATCH ADJACENT FLOOR SURFACES TO MATCH (E) SURFACES.

4. DISCONNECT AND REMOVE INCLUDING HOT AND COLD WATER, ASSOCIATED WASTE AND VENT SYSTEMS, ABOVE

CEILING AND BFF FROM THE (E) FIXTURE TO BE REMOVED. REMOVE AND CAP ALL ASSOCIATED PIPING AS SHOWN

ON FLOOR PLAN. NO DEAD LEGS OR ABANDONED PIPING.

5. DISCONNECT AND REMOVE (E) PLUMBING FIXTURE. DISCONNECT AND REMOVE (E)HW, CW, SAN AND V PIPING

SERVING (E) PLUMBING FIXTURE. CAP EACH ASSOCIATED PIPE TEMPORARILY UNTIL RECONNECTION DURING

NEW CONSTRUCTION.

6. REMOVE (E)FD AND CAP SAN PIPE BFF. PATCH ADJACENT FLOOR SURFACES TO MATCH (E) SURFACES.

7. REMOVE SECTION OF HW PIPE TO BE DEMOLISHED AND REPLACED IN KIND WITH NEW. REFER TO NEW WORK

DRAWINGS AND COORDINATE.

8. DISCONNECT AND REMOVE (AS SHOWN) ASSOCIATED PIPING CONNECTED TO THE (E)EEW/SH. REMOVE AND CAP

ALL ASSOCIATED PIPING AS SHOWN ON FLOOR PLAN. NO DEAD LEGS OR ABANDONED PIPING.

9. (E)FCO TO BE RAISED IN ORDER TO ALIGN WITH THE SCHEDULED NEW FLOOR.

10. DISCONNECT AND REMOVE PURIFICATION SYSTEM IN ITS ENTIRETY INCLUDING ALL ASSOCIATED APPURTENANCES

AND HAND OVER TO CFM.

11. DISCONNECT AND REMOVE EXPOSED AND CAPPED WASTE PIPING DOWN THROUGH FLOOR AND CAP IN CRAWL

SPACE AS SHOWN ON THE BELOW GROUND FLOOR PLANS.

12. REMOVE (E)1/2" PIPE CUT EVEN WITH THE TOP OF SHAFT AND IS ABANDONED. REMOVE ALL ASSOCIATED

ABANDONED PLUMBING PIPES ABOVE CEILING.

13. REMOVE PORTION OF EXISTING CW PIPE. PREPARE PIPING FOR FOR NEW WORK CONNECTION.

AS-BUILT DRAWINGS ARE NOT AVAILABLE TO POSITIVELY IDENTIFY ALL EXISTING CONDITIONS. CONTRACTOR MUST FIELD

VERIFY ALL PIPING LOCATED ABOVE CEILINGS, IN WALL CAVITIES AND BFF AS PER SOW, DUCTWORK, ELECTRICAL

CONDUITS, ETC. IN EVERY ROOM WITHIN THE SCOPE OF WORK AND IDENTIFY ACTIVE VERSUS INACTIVE COMPONENTS.

CONTRACTOR IS RESPONSIBLE FOR COMPLETE DEMO OF PIPING, FIXTURES, CARRIERS AND ASSOCIATED

APPURTENANCES, OR RELOCATION AS REQUIRED TO ACCOMMODATE NEW MECHANICAL AND ELECTRICAL WORK

ASSOCIATED WITH THIS PROJECT.

PIPING THAT IS TO BE DEMOLISHED MUST BE REMOVED COMPLETELY (INCLUDING ASSOCIATED APPURTENANCES) BACK

TO THE SOURCE AS CLOSE AS POSSIBLE TO AVOID DEAD LEGS AND CAPPED (HW,CW). PLUGGED (SAN,VENT) TO BE

PLUGGED AS CLOSE AS POSSIBLE TO MAIN OR BRANCH PIPE.

PLUMBING DEMOLITION KEYNOTES: SHEET NOTES:

1. SEE SHEET P001 FOR SYMBOLS AND ABBREVIATIONS.

2. SEE P501 SERIES FOR PLUMBING DETAILS.

3. SEE P700 SERIES FOR PLUMBING SCHEDULES.

4. ALL DAMAGE TO FLOOR SURFACES AS A RESULT OF THIS WORK, TO BE PATCHED TO MATCH ADJACENT SURFACES.

5. WHERE APPLICABLE, REFER TO DRAWING LS-001 FOR FIRE AND SMOKE BARRIER WALL LEGEND.

6. REFER TO ARCHITECTURAL SHEET A-AD101 & A-AD102 FOR LOCATIONS OF FLOOR SAW CUTTING. REFER TO DETAIL A7

ON SHEET A-AE503 UNDERSLAB PIPING DETAILS.

PLUMBING DEMOLITION KEYNOTES (CONTINUED)

14. CONTRACTOR SHALL CONTRACT WITH VAMC MEDICAL AIR SYSTEMS VENDOR (CARDINAL AIR : CONTACT CARMINE YEVOLI; (516) 352-0011)

TO REMOVE AND RELOCATE THE NON-FLAM NITROGEN AND NITROUS OXIDE GAS SYSTEMS FROM THE EXISTING GROUND FLOOR NON FLAM

GAS RM. 0216 TO THE FIRST FLOOR SECONDARY MANIFOLD ROOM 1091S.

THE CONTRACTOR SHALL FOLLOW OUTAGE NOTIFICATION TIME FRAMES LISTED IN SPECIFICATIONS.

THE ACTUAL RELOCATION OF MANIFOLDS, CONTROL PANELS, HEADERS, ETC. WORK SHALL OCCUR OVER A LIMITED CONTINUOUS SHORT TIME

DURATION (ONE WEEKEND MAXIMUM). INSTALLATION OF TEMPORARY MEDICAL AIR PIPING TO EXISTING RISERS; POWER AND MECHANICAL

VENTILATION SHALL BE PRE- INSTALLED IN PREPARATION OF A QUICK CHANGE-OVER. VAMC WILL RELY ON THE EXISTING SECONDARY MANIFOLD

SYSTEM FOR NITROGEN AND NITROUS OXIDE NEEDS DURING THE CHANGE-OVER. NITROGEN AND NITROUS OXIDE SUPPLY TO THE VAMC SYSTEM

SHALL REMAIN CONSTANT WITHOUT NO INTERRUPTION IN SERVICE.

SCOPE OF WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING:

· SWITCH VAMC SUPPLY OF NITROGEN AND NITROUS OXIDE GAS SUPPLY OVER TO SECONDARY MANIFOLD SYSTEM AT FIRST FLOOR

· DISCONNECT AND RELOCATE EXISTING MANIFOLDS , HEADERS, CONTROLS, GAS BOTTLES AND ALL ASSOCIATED APPURTENANCES (NITROGEN &

NITROUS OXIDE) SYSTEMS TO THE FIRST FLOOR SECONDARY MANIFOLD ROOM 1091S.

· CAP EXISTING HEADER PIPING AT RISER.

· SHUT-VALVES FOR EACH RESPECTIVE RISER TO BE TEMPORARILY CLOSED.

· PROVIDE TIE-IN CONNECTION FROM FIRST FLOOR SECONDARY MANIFOLD ROOM 1091S TO GROUND FLOOR EXISTING RISERS AS SHOWN ON

PLANS SHOWN.

· COMMSION, TEST AND CERTIFY SYSTEM

· CHANGE-OVER NITROGEN AND NITROUS OXIDE SUPPLY FROM SECONDARY MANIFOLD SYSTEM TO TEMPORARY SYSTEM

15. CONTRACTOR TO REMOVE AND DISPOSE OF THE NON OPERATIONAL MANIFOLD AND HEADER AND ASSOCIATED

APPURTENANCES, WHICH IS ORIGINAL TO THE BUILDING. ALL EMPTY GAS BOTTLES ARE TO BE TURNED OVER TO VAMC MEDICAL AIR SUPPLIER.

16. EXISTING COMP GAS ROOM 0215: COORDINATE REMOVAL OF GAS BOTTLES WITH VAMC. REMOVAL / RELOCATION OF GAS BOTTLES SHALL BE

BY VAMC AND/OR VAMC MEDICAL AIR SUPPLIER.

17. REMOVE PORTION OF EXISTING HW PIPE. PREPARE PIPING FOR FOR NEW WORK CONNECTION.

18. CONTRACTOR TO RE-ROUTE UNKNOWN PIPES AS REQUIRED TO BE OUTSIDE OF ROOM 0216, DURING RENOVATION OF THIS ROOM. ONE (1) 2"

COPPER PIPE AND TWO (2) 1/2" INSULATED COPPER PIPES. CONTRACTOR SHALL FIELD VERIFY THE ROUTING OF THIS PIPE. DURING THE FIELD

SURVEY THIS PIPE WAS INACCESSIBLE DUE TO MISC. ITEMS BEING STORED IN THIS ROOM.

PLUMBING EXISTING KEYNOTES:

1. PROTECT (E) STAINLES STEEL 3 WAY CONTROL BOXES LOCATED JUST BELOW THE CEILING DURING CONSTRUCTION.

2. (E) NITROGEN AND NITROUS OXIDE RISERS TO REMAIN.

3. (E) NITROUS OXIDE PIPE TO REMAIN FIELD VERIFY FOR CONT.

4. (E) VALVE TO REMAIN CLOSE.

DN

RAMP

SK

EWC

UR

LAV

(E)WC

REMOVE (E)12X12 PIT. CAP

WASTE PIPE BFF - PATCH

ADJACENT FLOOR SURFACES

TO MATCH NEW SURFACE

REMOVE (E) 6" SAN

PIPE DOWN TO

CRAWL SPACE

REMOVE (E) TRENCH

DRAIN AND PAN - PATCH

FLOOR TO MATCH

ADJACENT SURFACES

(E)SH

(E)4" SAN

DN.

REMOVE

(E)1-1/2" V UP

DISCONNECT AND REMOVE (E)4" ST FROM

APROX. 12" ABOVE CEILING (EXISTING RD

ABOVE TO REMAIN), DN TO BFF FOR

RECONNECTION DURING NEW CONSTRUCTION

D1

D1

D5

D7

D17

(E)1/2" HW

(E)1/2" CW

1-1/2" VENT PIPE UP

& 2" SAN DN FIELD VERIFY

FOR CONT.

(E)LAV

REMOVE

INSULATION

ON (E)PIPE

(E)3/4" CW EXPOSED

ON WALL

(E)3" V DN DEMOLISH

RISER FOR NEW WORK

(E)3"SAN

(E)3"CO

REMOVE (E)1/2"CW

& (E)HW DN

(E)3" V

(E)2" V

(E)2"V CRIMPED

CLOSED (ABANDONED)

(E)2" DRAIN SPILLS

ABOVE (E)FD

(E)3" SAN DN DEMOLISH

VERTICAL RISER FOR NEW WORK

REMOVE (E)1"

ABANDONED

PIPING - STOPS

ABOVE SHAFT

PATCH WALL PIPE

PENATRATION TO

MATCH ADJACENT

SURFACES

REMOVE (E)4" THICK

CONCRETE PAD

REMOVE

INSULATION

ON (E)8" PIPE

(E)2" D

D9

(E)1-1/2" V

EEW/SH

D15

ABANDONED

D14

(E)1-1/2" V

(E)1" HW

(E)1-1/2" V UP

(E)1-1/2" CW

(E)1/2" HW

(E)2"CW

REMOVE (E)HEAT TRACE

SYSTEM AND PIPE INSULATION

REMOVE (E)HEAT

TRACE SYSTEM

(E)1-1/4" CW

D3

D8

(E) 2" DN

FROM CEILING

D18

D16

(E)1/2"

REMOVE AND CAP DRAIN

BFF AND AND PATCH PIPE

OPENING TO MATCH

ADJACENT SURFACES

(E)1-1/2" CW

(E)3/4" HW

(E)FD

A-PD101

A-PD102

A-

PD

A-

PD

3 (E)1" HW

(E)1" CW

(E)FCO (E)FCO

D13

(E) PIPE DN

CAP BFF

D3 (E)FD

D4

D4

D1

D1

D13

D3 (E)FD

D9D9

AA

EX

Z

U

EX

AA

EX

12 323028

22 23 24 2611

EX EX

EX EX

EX EX

Y

V

W

X

Z

AA

U

U

V

W

X

U

TM KS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSU…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .