Attachment 01d - Addendum R1-001EP400Ga_041EP101_041EP702-Door Schedule-EHRM-689-22-700.pdf
PDF 5 MB Posted
- Attached to
- Z2DA--689-22-700 EHRM IU West Haven VAMC This ONLY for the PCAC VISN 1 Construction MATOC Pool
- Solicitation number
- 36C77626R0106
About this file
This is a set of electrical construction drawings for a federal facility renovation project managed by the U.S. Department of Veterans Affairs. The documents include demolition electrical plans, electrical power plans, lighting and receptacle plans, and electrical panel schedules for Buildings 41 and 42, Level 01, and Room G192.
The scope of work requires the contractor to demolish existing electrical equipment, conductors, and raceways associated with walls being removed and equipment upgrades, then install new electrical infrastructure including power panelboards, lighting fixtures, receptacles, access control panels, door hardware power supplies, and emergency generator connections. Key requirements include field verification of all existing power and circuitry; coordination of electrical system shutdowns with VA personnel to maintain power to essential equipment during construction; provision of backup emergency power with tie-in plans conforming to VA standards; sealing of wall and ceiling penetrations to match fire ratings; updated circuit panel directories for all affected panels; pull boxes for feeder runs exceeding 250 feet or having more than 270 degrees of total bend; and equipment mounted outside rated NEMA 3R. The contractor must coordinate with the architect, mechanical trades, and VA on pull box locations, power supply locations for electrified door hardware, and telecommunications bonding requirements. Panel schedules indicate both existing circuits (shown in gray text) and new revised circuits (shown in black text) with specified amperage ratings and load requirements across multiple distribution panels.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
J
B
B
B
AAAAAAA
A
A
A
A
A
A
EP502
B
B
B
B
B
B
B
B
AAAAAAA
AAAA
Mo
A A
B B
A A
B B
K
H
TYP.
EXISTING FAN
COIL UNIT
K
H
001-G192A
001-G192B
001-FC-04-G192
P-TR-2A
EP504
001-FC-03-G192
TR
G192
98 SF
1-P-18 1-P-19
TO SHEET 001EP100SG
P-TR-2B
001-G192A-23
DD
001-G192A-10,12
001-G192A-16,18
LOCKER
G192C
45 SF
OFFICE
G192A
87 SF
2-DOOR
ACCESS
CONTROL
PANEL
001-G192A-23
EXISTING FAN
COIL UNIT
TYP.
FROM SHEET
001EP100SG
1-P-5
FROM SHEET
001EP100SG
1-P-7 1-P-12 1-P-21
001-G192A-23
K
H
TYP.
7 7
K
H
L2
001-G192B
DATA RACK,
TYP.
TR
G192
98 SF
LOCKER
G192C
45 SF
L2
001-G192A
001-G192A-4
L2L2
EP508 TYP.
EP508TYP.
OFFICE
G192A
87 SF
G192
STORAGE
GENERAL
G192
109 SF
STORAGE
GENERAL
G192B
87 SF
STORAGE
GENERAL
G192A
88 SF
STORAGE
GENERAL
G192
109 SF
STORAGE
GENERAL
G192B
87 SF
STORAGE
GENERAL
G192A
88 SF
AREA SHOWN
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER
FEEDERS. REFERENCE GENERAL SYMBOL LEGEND FOR
ADDITIONAL INFORMATION.
LEGEND
'A' SIDE POWER, CONCEALED WHERE POSSIBLE
'B' SIDE POWER, CONCEALED WHERE POSSIBLE
'A' SIDE POWER, UNDERGROUND /UNDERFLOOR
'B' SIDE POWER, UNDERGROUND /UNDERFLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
7/
/2
2:
:1
AM
Au to de sk
D oc s:
//6
-2
2-
VA
C T
W es t H av en E
H R
M
IU
/V
AW
H _0
1_
EL
_S D
B.
rv t
001EP400Ga
BLDG 001 - LEVEL 0G - ENLARGED
ELECTRICAL PLANS
DCW/MMM RTS/JGD
100% CONSTRUCTION
DOCUMENTS
04/20/2026
689-22-700EHRM INFRASTRUCTURE
UPGRADES - WEST HAVEN
VA CT WEST HAVEN
950 CAMPBELL AVENUE, WEST HAVEN, CT 06516
3/8" = 1'-0"001EP100G
1 RM G192 - DEMOLITION ELECTRICAL PLAN
3/8" = 1'-0"001EP100G
2 RM G192 - ELECTRICAL PLAN
3/8" = 1'-0"001EP100G
3 RM G192 - DEMOLITION LIGHTING PLAN
3/8" = 1'-0"001EP100G
4 RM G192 - LIGHTING AND RECEPTACLE PLAN
2'0 4' 6'
PROJECT
NORTH
2'0 4' 6'
PROJECT
NORTH
2'0 4' 6'
PROJECT
NORTH
GENERAL NOTES
KEY PLAN
PROJECT
NORTH
2'0 4' 6'
PROJECT
NORTH
1.
2.
3.
4.
5.
6.
7.
8.
DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED.
ALL RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE
DEMOLISHED SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS OTHERWISE
NOTED
CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL REMAIN
ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL CONFORM WITH
VA STANDARDS.
SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING, IF REQUIRED. COORDINATE WITH ARCHITECTURAL
DRAWINGS AS REQUIRED.
REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER
RUNS EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL BOX
PLACEMENT AND SIZING BY CONTRACTOR. COORDINATE PULL BOX LOCATIONS WITH
ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
KEY NOTES
1 EXISTING EQUIPMENT SHALL BE DEMOLISHED. ASSOCIATED CONDUIT AND WIRE
SHALL BE DEMOLISHED BACK TO SOURCE.
SOURCE A POWER PANELBOARD "001-G192A".
SOURCE B POWER PANELBOARD "001-G192B".
PROVIDE SECONDARY BONDING BUSBAR. REFERENCE TELECOMMUNICATIONS
BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL INFORMATION.
OVERHEAD TR RACK SOURCE A AND SOURCE B POWER RECEPTACLE.
FURNISH AND INSTALL POWER SUPPLY WITHIN JUNCTION BOX AS INDICATED ABOVE
ACCESSIBLE CEILINGS. VERIFY LOCATIONS WITH ARCHITECT. PROVIDE (1) POWER
SUPPLY FOR EACH DOOR OPENING. PROVIDE 120V POWER TO ADEQUATELY SERVE
DOORS WITH ELECTRIFIED DOOR HARDWARE AND MAKE CONNECTIONS AS
REQUIRED. SEE REQUIREMENTS IN "08 71 00 - DOOR HARDWARE". COORDINATE WITH
ARCHITECT AND DOOR INSTALLER.
EXISTING SWITCH SHALL BE RELOCATED.
RELOCATED SWITCH. EXTEND CONDUIT AND WIRE AS REQUIRED.
CIRCUIT LIGHT TO EXISTING LIGHTS IN OFFICE G192A.
EXISTING MECHANICAL UNIT SHALL BE DEMOLISHED. ASSOCIATED CONDUIT AND
WIRE SHALL BE DEMOLISHED BACK TO SOURCE. REFERENCE MECHANICAL PLANS
FOR ADDITIONAL INFORMATION.
PROVIDE MOTOR RATED SNAP-SWITCH DISCONNECT FOR MECHANICAL UNIT AS
SHOWN. COORDINATE WITH MECHANICAL CONTRACTOR AS REQUIRED.
EXISTING EQUIPMENT SHALL BE DEMOLISHED. ASSOCIATED RACEWAYS AND
CONDUCTORS SHALL BE DEMOLISHED BACK TO SOURCE. PROVIDE ANY ADDITIONAL
CIRCUITING AS REQUIRED TO MAINTAIN REMAINING ROOM LIGHTING POWER AND
CONTROLS.
PROVIDE TBB AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
PROVIDE SBC AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
Revisions: Date:
07-28-2026ADDENDUM PRE-BID RFI 1
A A
B B
A A
B B
J
J
J
J
A A A A A A
BBBBBB
A A A A A A A A A A A A A A
BBBBBBBBBBBBBB
E
E J
J
J
J
A
A
A
A
A
A
A
A
A
A
AAAAAAA
AAAAAA
AAAAAAA
AAAAAAA
A
A
A
A
A
A
A
A A A A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A A A A A A A A A A A A A A A A A A A
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBBBBBB
BBBBBBB
BBBBBBB
BBBBBBB
BB
B
B
B
B
B
B
B
B
AA BB
B B
BB
A
A B
B
B
B
AA
AA
AAAAAAAAAAA
TYP.
EP506
EP507
EP507
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A A A BBBB
AAAAAAAAAAAAAAAAAAAAAAAAAAA
A A A A
B B B
AA
AAAAAAAAA
A A
AAAAAAA
BBBBBBBBBB
BBBBBBB
A
A
A
A
A A A A A A A A A
B B B
B
B
B
B
B
B
B
B
B
B
B
BBBBBBBBBBBBBBBBBBBBBBBBBBB
BBBBBBB
B
B
B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B
B
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A A A
B B B
AAAAAAA
B
B
B
B
B
AAAAAAA
AA
AAAAAAA
A
A
A
A
A
A
A
A
A
AAAAAAA
AAAAAAAAAAAAAA
AAAAAAA
AAAAAAAAAAA
A
A
A
A
A
A
AAAAAAA
A
A
A
B
B
AAAAAAA
BBBBBBB
B
B
B
BBBB
B
B
B
B
B
B
B
BBBB
A
A
A
A
A
A
A
A
A
AAAAA
AA
AAAAAAA
BB
A
A
A
A
BBBBBBBBBBBBBBBBBB
B
B
BBBBBBB
B B B B B B B B B B B B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBBBBBBBBBB
A A A A A
A
A
BBBBBBB
B B
BBBBBBB
B B
AAAAAAA
AAAAAAA
AAAAAAA
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER
FEEDERS. REFERENCE GENERAL SYMBOL LEGEND FOR
ADDITIONAL INFORMATION.
LEGEND
'A' SIDE POWER, CONCEALED WHERE POSSIBLE
'B' SIDE POWER, CONCEALED WHERE POSSIBLE
'A' SIDE POWER, UNDERGROUND /UNDERFLOOR
'B' SIDE POWER, UNDERGROUND /UNDERFLOOR
V
V
1 3 4
C
B
A
DATA CENTER
1190 SF
ENTRANCE
ROOM #1
189 SF
ENTRANCE
ROOM #2
106 SF
MECH
275 SF
ELEC
99 SF
SECURE
STORAGE
116 SF
FIRE RISER
45 SF
CORRIDOR
561 SF
GENERATOR
ENCLOSURE
955 SF
ROOF
ACCESS
44 SF
041-107B
041-107A
DATA RACK, TYP.
041-105B
041-105A
DATA RACK, TYP.
P-TR-2A
P-TR-2B
P-TR-2B
P-TR-2A
HOUSE KEEPING PAD
041-PNL-A
TRANSFORMER "041-TX-PNL-A" (ABOVE)
TRANSFORMER "041-TX-UPS-A" (BELOW)
041-DP-A
041-ATS-A
041-PNL-E
041-MTS
TRANSFORMER "041-TX-PNL-B" (ABOVE)
TRANSFORMER "041-TX-UPS-B" (BELOW) 041-DP-B
041-ATS-B
041-PNL-N
041-PNL-B
GENERATOR CONNECTION ENCLOSURE
"041-GCE-E"
041-P-36
041-P-37041-P-46
041-P-38
041-P-52
1.1
A.1
B.1
3-P-01B
041-P-05
041-P-09
041-P-08
041-P-13
041-P-16
2.1
EP509 TYP.
EP502
EP502
041-P-03
041-P-02
STORAGE
364 SF
ELECTRICAL
140A
60 SF
TREATMENT
ROOM
1,136 SF
ANIMAL
ROOM 2
196 SF
192 SF
ANTE ROOM
135 SF
MOTOR STARTER
"041-MS-SF"
MOTOR STARTER
"041-MS-EF"
041-PNL-B2
041-P-07
041-PNL-HA
041-PNL-A2
041-PNL-LS
EPO-P1 3
EP506
EP506
ACCESS
CONTROL PANEL
041-FPS-01-121
041-FP-01-121
041-C-26
041-CP-HT
042-PNL-LS
041-042-ATS-LS
GENERATOR
041-P-74 041-P-73
041-L-02 041-L-01
ATS "3-4-5-ATS-A"
3-P-01A
TO SHEET
003EP101
3-P-01C
GRINDER PUMP
CONTROL PANEL041-PNL-A2-17
41-FT-01-121
041-C-18
041-C-01 041-C-02 041-C-03
041-C-07 041-C-11
041-C-04 041-C-08
041-C-25
041-C-24
041-C-10 041-C-06
041-C-27
041-C-31
041-C-19
041-C-32 041-C-21
041-C-16
041-C-13
041-C-17
041-C-12
041-C-14 041-C-15
041-C-33
041-C-22
041-C-29
041-C-09 041-C-05
041-C-28
041-C-20
041-C-30
041-P-76
041-C-23
DD
DD
041-PNL-A2-21
041-107A-29
041-PNL-A2-15
041-105A-23
041-P-04
GRINDER PUMP
041-P-20 041-P-21 041-P-22
041-P-47
041-P-75
041-P-34
041-P-50 041-P-39
041-P-51
041-P-19
041-P-35
041-ECB-TIE
041-P-15 041-P-14
041-P-48 041-P-27
041-P-28
041-P-49
041-P-10 041-P-01F
041-P-23
042-CP-HT
EPO-P23
TO SHEET
003EP101
5-P-02A
041-P-06
041-UPS-B1
041-UPS-A1
VLT-041-5
041-P-01E
VLT-041-47
041-P-01D
FIRE ALARM
CONTROL PANEL
041-PNL-A-2
041-PNL-A-2
041-PNL-A-2
041-PNL-A2-15
ACCESS CONTROL
PANEL, 8-DOOR
041-105A-23
041-PNL-A-2
AREA SHOWN
BLDG 41
BLDG 42
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
7/
/2
3:
:1
AM
Au to de sk
D oc s:
//6
-2
2-
VA
C T
W es t H av en E
H R
M
IU
/V
AW
H _D
AT
A
C
EN
TE
R
_E L_
SD
B.
rv t
041EP101
BLDG 41 AND 42 - POWER PLAN - LEVEL 01
DCW/MMM RTS/JGD
100% CONSTRUCTION
DOCUMENTS
04/20/2026
689-22-700EHRM INFRASTRUCTURE
UPGRADES - WEST HAVEN
VA CT WEST HAVEN
950 CAMPBELL AVENUE, WEST HAVEN, CT 06516
3/16" = 1'-0"041EP201
1 BLDG 41 AND 42 - POWER PLAN - LEVEL 01
1 FURNISH AND INSTALL POWER SUPPLY WITHIN JUNCTION
BOX AS INDICATED ABOVE ACCESSIBLE CEILINGS. VERIFY
LOCATIONS WITH ARCHITECT. PROVIDE (1) POWER SUPPLY
FOR EACH DOOR OPENING. PROVIDE 120V POWER TO
ADEQUATELY SERVE DOORS WITH ELECTRIFIED DOOR
HARDWARE AND MAKE CONNECTIONS AS REQUIRED. SEE
REQUIREMENTS IN "08 71 00 - DOOR HARDWARE".
COORDINATE WITH ARCHITECT AND DOOR INSTALLER.
OVERHEAD TR RACK SOURCE A AND SOURCE B POWER
RECEPTACLE.
GENERATOR EMERGENCY POWER OFF SWITCH. ONCE
INITIATED, SWITCH SHALL DE-ENERGIZE THE GENERATOR.
CONTRACTORS SHALL COORDINATE WITH GENERATOR
MANUFACTURER AND PROVIDE CONDUIT AND WIRE AS
REQUIRED.
BMS NETWORK EXPANSION SWITCH LOCATED IN
TELECOMMUNICATIONS RACK. COORDINATE FINAL
PLACEMENT WITH VA. REFERENCE DETAIL '1' ON SHEET
EP510 FOR ADDITIONAL INFORMATION.
ALL EXISTING UNDERGROUND CONDITIONS, INCLUDING
PIPING, RACEWAYS, ETC., MAY NOT BE SHOWN FOR
CLARITY. REFERENCE CIVIL, MECHANICAL, AND
TELECOMMUNICATIONS DRAWINGS FOR ADDITIONAL
INFORMATION.
PROVIDE CONDUIT AND WIRING FROM PUMP CONTROL
PANEL AS REQUIRED FOR ALL POWER AND CONTROL
DEVICES INCLUDING FLOATS AND PUMPS PER
MANUFACTURER'S REQUIREMENTS. REFERENCE CIVIL
SHEET CU200 FOR ADDITIONAL INFORMATION.
REFERENCE "ELECTRICAL VAULT / HANDHOLE SCHEDULE"
ON SHEET EP701 FOR ADDITIONAL INFORMATION.
GENERAL NOTES
KEY PLAN
1.
2.
3.
4.
5.
6.
7.
8.
ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR
CLARITY. CONTRACTOR SHALL FIELD VERIFY ALL POWER,
LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED. ALL
RACEWAYS AND CONDUCTORS ASSOCIATED WITH
EQUIPMENT TO BE DEMOLISHED SHALL BE DEMOLISHED
BACK TO THEIR SOURCE, UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL REMOVE ALL ELECTRICAL EQUIPMENT,
CONDUCTORS AND RACEWAYS ASSOCIATED WITH WALLS
BEING REMOVED, AND IN ALL LOCATIONS WHERE JUNCTION
BOXES WILL NOT REMAIN ACCESSIBLE AFTER
INSTALLATION, UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL
ELECTRICAL SYSTEM SHUTDOWNS AND PHASING WITH THE
VA PRIOR TO PERFORMING REQUIRED EQUIPMENT
UPGRADES. CONTRACTOR TO PROVIDE BACKUP
EMERGENCY POWER AND DETERMINE TIE-IN/CONNECTION
PLAN WITH EXISTING EQUIPMENT. POWER TO ALL EXISTING
ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND
SHALL REMAIN ACTIVE DURING CONSTRUCTION. BACKUP
POWER AND TIE-IN SHALL CONFORM WITH VA STANDARDS.
SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO
MATCH EXISTING FIRE RATING OR NEW FIRE RATING, IF
REQUIRED. COORDINATE WITH ARCHITECTURAL DRAWINGS
AS REQUIRED.
REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR
ADDITIONAL INFORMATION.
CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL
DIRECTORIES FOR ALL PANELS THAT CONTAIN CIRCUITS
IMPACTED BY THIS PROJECT.
CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL
FEEDERS WHERE FEEDER RUNS EXCEED 250FT OR HAVE
MORE THAN 270 DEGREES OF TOTAL BEND. PULL BOX
PLACEMENT AND SIZING BY CONTRACTOR. COORDINATE
PULL BOX LOCATIONS WITH ALL OBSTRUCTIONS, TRADES,
AND VA AS REQUIRED.
ALL ELECTRICAL EQUIPMENT MOUNTED OUTSIDE SHALL BE
RATED NEMA 3R.
KEY NOTES
TRUE
NORTH
PROJECT
NORTH
4'0 8' 12'
Revisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
7/
/2
3:
:0
AM
Au to de sk
D oc s:
//6
-2
2-
VA
C T
W es t H av en E
H R
M
IU
/V
AW
H _G
EN
ER
AL
SH
EE
TS
_E L_
SD
B.
rv t
041EP702
BLDG 041 - ELECTRICAL PANEL SCHEDULES
DCW/MMM RTS/JGD
100% CONSTRUCTION
DOCUMENTS
04/20/2026
689-22-700EHRM INFRASTRUCTURE
UPGRADES - WEST HAVEN
VA CT WEST HAVEN
950 CAMPBELL AVENUE, WEST HAVEN, CT 06516
GENERAL NOTES
1.
2.
3.
4.
CONTRACTOR SHALL UPDATE ALL PANEL CIRCUIT
DIRECTORIES TO INDICATE IN ANY AND ALL CHANGES; ALL
REVISED CIRCUIT DIRECTORIES SHALL BE TYPEWRITTEN.
FOR ALL "REVISED" PANEL SCHEDULES REFERENCE
ASSOCIATED EQUIPMENT LOAD SCHEDULE FOR OVERALL
PANEL LOAD. "REVISED" PANEL SCHEDULES ON THIS SHEET
ARE SHOWN FOR ADDED BRANCH CIRCUIT SIZING ONLY.
ALL DIGITAL POWER METERS (DPM) AND SURGE
PROTECTIVE DEVICES (SPD) ARE INTEGRAL TO ELECTRICAL
DISTRIBUTION EQUIPMENT, UNLESS OTHERWISE NOTED.
SCHEDULES WITH GRAY TEXT INDICATE EXISTING
PANELBOARD RATINGS, CIRCUITS, AND LOADS. BLACK TEXT
INDICATES REVISED CIRCUITS, PROVIDED EQUIPMENT, AND
ADDITIONAL LOAD.
Revisions: Date:
| 001EP400Ga |
| 041EP101 |
| 041EP702 |
| 041TN101 |
| 001TN400Ga |
File details come from the government source that posted it. Updated .