589A5-21-700_TOPEKA_EHRM_SURVEY LOCATIONS-Markup.pdf

PDF 17 MB Posted

Attached to
Y1DA--589A5-21-700 EHRM INFRASTRUCTURE UPGRADES (VA-24-00076324) Topeka, KS
Solicitation number
36C77624B0026_1
Issued by

About this file

This file contains architectural markup drawings showing telecommunications room locations and hazardous materials survey information for an EHRM (Electronic Health Record Modernization) infrastructure upgrade project at the VA Medical Center in Topeka, KS. The drawings identify areas within multiple buildings (Buildings 1, 2, 3, 4, 5, 6, 9, 20, 21, 22, 23, 24, 25, 40, 41, 42, 43, and 273) where telecommunications rooms (TR) will be installed or modified.

The drawings include floor plans with detailed locations of TRs, demolition notes, construction notes, and hazardous materials survey information indicating areas containing asbestos-containing materials (ACM) and lead-based paint (LBP). The markups use color coding to indicate different conditions: green for areas where ACM/LBP testing is complete, blue for areas not in scope but tested, and red for areas requiring testing. Each building's drawings include specific room numbers, dimensions, and technical requirements for TR installations. The drawings also contain general demolition notes, ceiling removal scopes, floor plan legends, and rated partition legends to guide construction work.

View the file

Other files

File Type Posted
36C77624B0026 0007.docx DOCX document
36C77624B0026 0006.docx DOCX document
Government Answers to Contractor questions.docx DOCX document
Add Spec Section 23 21 13 Attachment A.pdf PDF
Revised Vol3 Drawing_M503.pdf PDF
Revised Spec Section 23 21 13.pdf PDF
36C77624B0026 0005.docx DOCX document
Pages from Addendum1_Vol2_2of2__20241209.pdf PDF
Colmery-ONeil VA Medical Center - Asbestos and Lead Survey Report signed.pdf PDF
Submittal 024 Pipe - Valve- Fittings 8-8-17.pdf PDF
Pages from Addendum1_Vol2_1of2__20241209.pdf PDF
EHRM Contractor Parking and Laydown.pdf PDF
Addendum1_Specifications_20241209.pdf PDF
Addendum1_Vol3_2of3_20241209.pdf PDF
230415-000 Topeka VA Geotech Final Report_S.pdf PDF
Addendum1_Vol3_1of3_20241209.pdf PDF
Addendum1_Vol3_3of3_20241209.pdf PDF
36C77624B0026 0004.docx DOCX document
589A5-21-700_Topeka KS_EHRM_Tech Q1_20241210.docx DOCX document
589A5-21-700_Topeka EHRM_IFB_BOD_Blast.pdf PDF
589A5-21-700_19550421_Steam Distro Plot Plan.pdf PDF
Submittal 023B Perma Pipe Fittings 8-21-17.pdf PDF
589A5-21-700_Topeka KS_EHRM_Tech Q2_20241210.docx DOCX document
Addendum1_Vol1_20241209.pdf PDF
36C77624B0026 0003.docx DOCX document
36C77624B0026 0002.docx DOCX document
S04_Site Visit Sign-in Sheet_Topeka KS.pdf PDF
S06- 36C77624B0026 0001.docx DOCX document
Attachment 1 - 589A5-21-700_Topeka EHRM__SOWV3.docx DOCX document
Attachment 16 - 589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 3_1.pdf PDF
Attachment 15 - 589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 2-8.pdf PDF
Attachment 10 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 91-129.pdf PDF
Attachment 3 - DB Wage Determination Topeka-KS.pdf PDF
Attachment 8 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 3_1-90.pdf PDF
Attachment 4 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 2_118-180.pdf PDF
Attachment 11 -589A5-21-700_Topeka EHRM_IFBR2_Spec-VOL1_032224.pdf PDF
Attachment 5 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 2_181-240.pdf PDF
Attachment 14 - 589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 1_134-204.pdf PDF
Attachment 13 - 589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 1_1-18.pdf PDF
Attachment 9 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 3-2.pdf PDF
Attachment 12 -589A5-21-700_Topeka EHRM_IFBR2_Spec-VOL2_032224.pdf PDF
Attachment 20 -Site Visit Instructions.docx DOCX document
Attachment 19 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 2_111-117.pdf PDF
Attachment 6 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 2_241-281.pdf PDF
Attachment 18 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 2_1-110.pdf PDF
36C77624B0026_1.docx DOCX document
Attachment 2- Limitations on Subcontracting - Construction.docx DOCX document
Attachment 7 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 2-7.pdf PDF
Attachment 17 -589A5-21-700_Topeka EHRM_IFB R2 Drawings_Vol 1_19-133.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T101 T102

GENERAL - SITE ORIENTATION AND STAGING

PLAN

DA JM

GI-201

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

K:

\C

C G

_P R

O

JE

C

TS

\2

1\

-1

T op ek a

EH

R M

C

1R

\4

- D es

D oc s\

2- D ra w in gs

\W O

R

KI

N G

\A ut oC

AD

\G I2

.d w g

/7

/2

4:

:3

PM

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE

UPGRADES

COLMERY O'NEIL VA HEALTH CARE

21-116

Revisions: Date:

www. bancroft-ae.com

3300 Dundee RD.

Northbrook, IL 60062

T: 847.952.9362

35% SCHEMATIC DESIGN SUBMISSION 07-12-22

95% CONSTRUCTION DOCUMENTS SUBMISSION 10-31-23

100% FINAL BID DOCUMENT SUBMISSION

11/28/2023

12-19-23

Bancroft Project No: 21-116

VA REVIEW ONLY - NOT FOR CONSTRUCTION

35% SCHEMATIC DESIGN SUBMISSION R1 09-21-22

35% SUBMITTAL II 06-13-23

65% DESIGN DEVELOPMENT SUBMITTAL 09-12-23

AREAS OF NEW WORK FOR EHRM - HAZORDOUS MATERIALS MARKUP 11.15.2024

ITEMS IN RED: AREAS WITHIN SCOPE OF WORK WHERE ACM & LBP SURVEY AND TESTING YET TO BE PROVIDED AND ASSUMED TO HAVE ASBESTOS CONTAINING MATERIALS (ACM) AND/OR LEAD BASED PAINT (LBP) SIMILIAR TO THE ADJACENT ROOMS ALREADY SURVEYED AND TESTED

ITEMS IN GREEN: AREAS WITHIN SCOPE OF WORK WHERE ACM & LBP SURVEY AND TESTING COMPLETED PER SURVEY REPORT 8/16/2022

ITEMS IN BLUE: AREAS NOT IN SCOPE OF WORK BUT ACM & LBP SURVEY AND TESTING COMPLETED PER SURVEY REPORT 8/16/2022

NEW BUILDING

PLAN MARKUP NOT PROVIDED

FOR THESE BUILDINGS / ROOM

LOCATIONS - SEE ACM/LBM

SURVEY REPORT 8/16/2022

STEAM TUNNEL

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

DN

A

B

C

D

E

F

1 3 4 5 11 13 16 18 19 21 23 25 26 27 286 8 9

11.1

14 15 17

K

L

M

29 30

G

O

Q

S

T

U

V

P

S.2

S.1

Q.1

U.1

V.1

V.2

W.1

X

Y

8.26.36.2 10.19.3 12.111.23.8

Z.4

4.7 6.1 8.1 11.7

Z.3

Z.2

24 31 32

N

7 222010 12

18B 20B 22B 24B 24C

H

I

J

R

W

Z.1

22D

UPUP

UP

B23

B23G

B23A B23B

B23E B23D B23C

C03A

A9E

A9C A9D

B5

C3

A17

A12

A30

A21

A21E

A21A

A13A A13B

A1

A10F

A3B

A3

A3A

A13

A20E

A20

A17F

C7

C7B

C4EC3EC3F

A19D

C7A

C7G

C7C

C7D

A19

C5

C7H

C7I

C6A19B

C1A18

A18A C2

A17A

A5

B1E

A7A8A9

A10E

A10

A4

A7E

A9A

A11

A14

A15

B4

B3

B13E

B22

B14A

B14

A2

A2A

A2B

A2C A2D

A19DC0-1

C8A

C20

C23

C24 C25

C28

C27

C26

C22 C21

C18C19

C17

C8

C9

C12

C14

C8B

C10 C11

C13

C15 C14A

C14B C14C

C16 C16A

C04

A16D

B2 B2B

B2A

B15B16 B17

B1

A16

A16C

A16A

A16E A16B

B22E

B1B

C0-2

C1A

B21

A19C

B1C

B6C

A16G

A9B

B43M B42

B42A B39

B38

C0-5B

C0-5A

C0-3

A9C

C114C

C11A

CB-8

B6D

A0-E3

A0-E1

A0-E2

A0-E4

B42B

B41

B40

B6P

B6 B8A

B7

B13CB13

B12

B9

B10

B11

B11A

B6M

B7M

B8 C0-3E

C0-3C

C0-3B B8C

B13B

B13A

A10G

A10B

A10A

A10C A10D

B20

B23F

C20A A19A

1,2,3&4 A-01-402

1&2

FP-01-401

1,2,3&4 A-01-401

5,6,7&8 A-01-401

3&4 M-01-401

1&2 M-01-402

1&2

FP-01-402

1&2 M-01-401

1&2

FP-01-403

RATED PARTITION LEGEND

CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.

1 HR FIRE BARRIER

2 HR FIRE BARRIER

SMOKE BARRIER

1 HR FIRE BARRIER (EXISTING)

2 HR FIRE BARRIER (EXISTING)

SMOKE BARRIER (EXISTING)

1. REMOVE AND STORE CEILING TILES IN THIS AREA AS REQUIRED FOR MECHANICAL

DUCTWORK, PIPING, ELECTRICAL CONDUIT, TECHNOLOGY EQUIPMENT AND/OR

SECURITY INSTALLATION. REINSTALL TILES AND GRID WHEN WORK IS COMPLETED.

REPLACE ANY DAMAGED TILES AND GRIDS TO MATCH EXISTING. G.C. SHALL

TEMPORARILY ERECT A SUSPENDED PLASTIC BARRIER 6 MIL AROUND AREA OF

CEILING WORK TO BE PERFORMED DURING ONE SHIFT AND G.C. SHALL REMOVE

SUSPENDED PLASTIC BARRIER AT THE END OF SHIFT. G.C. SHALL MOP CLEAN THIS

AREA OF WORK. PRIOR TO TURNING OVER AREA TO VA. AFTER WORK HOURS WILL

REQUIRE ADDITIONAL COORDINATION WITH THE VA.

A. REFER TO TECHNOLOGY AND ELECTRICAL FOR FULL REQUIRED INSTALLATION

AND DEMOLITION WORK

B. ALL EXISTING LIGHTING, CONDUIT, DUCTWORK, MECHANICAL GRILLS, &

SPRINKLER HEADS TO REMAIN IN EXISTING LOCATIONS AND PROTECTED

UNLESS OTHERWISE NOTED.

C. ANY ELECTRICAL FIXTURES AND DEVICES THAT ARE NOT IDENTIFIED ON THESE

DRAWINGS IN THE AREAS OF CEILING DEMOLITION, ARE TO BE CAREFULLY

REMOVED FROM THE CEILING, PROTECTED, TEMPORARILY HUNG AND THEN

REATTACHED IN THE SAME LOCATIONS AS WHICH THEY WERE FOUND PRIOR TO

DEMOLITION.

D. CONTRACTOR TO CAREFULLY REMOVE SECTIONS OF EXISTING CEILING TILE TO

ALLOW FOR THE INSTALLATION OF ALL REQUIRED CONDUIT AND ELECTRICAL

EQUIPMENT PER CONTRACT DRAWINGS. CONTRACTOR SHALL REINSTALL

CEILING IN EXACT LOCATION. CONTRACTOR TO REPLACE ANY CEILING

GRID/TILES DAMAGED DURING CONSTRUCTION, MATCHING EXISTING. REFER TO

ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION.

E. IF A RATED ASSEMBLY IS NOT INSTALLED BY END OF SHIFT IT MUST BE

PROTECTED OVERNIGHT.

GENERAL DEMOLITION NOTES

CEILING DEMOLITION LEGEND

CEILING DEMOLITION KEY NOTESX

1. REPLACE EXISTING A,B&C TYPE FIRE EXTINGUISHER WITH CLEAN AGENT A,B&C

TYPE FIRE EXTINGUISHER.

2. INSTALL CLEAN AGENT A,B&C TYPE FIRE EXTINGUISHER IN SEMI-RECESSED

CABINET SET IN NEW GYP. BD. ON METAL STUD ASSEMBLY (1-HR RATED)

3. INSTALL CLEAN AGENT A,B&C TYPE FIRE EXTINGUISHER IN SEMI-RECESSED

CABINET IN EXISTING WALL WRAP CABINET IN TYPE 'X' GYPSUM BOARD.

FLOOR PLAN KEY NOTESX

KEYNOTE 11

A. ALL WORK ASSOCIATED WITH TEMPORARY CEILING REMOVAL AND INSTALLATION

OF CABLING SHALL BE CONSIDERED AS NO MORE HAZARDOUS THAN NORMAL

OPERATIONS. INFECTION CONTROL REQUIREMENTS FOR THIS WORK SHALL

INCLUDE "VISQUEEN" TYPE BARRIER AROUND WORK AND/OR INFECTION CONTROL

MODULES WITH VA STATION APPROVAL. CONTRACTOR SHALL ALSO ADHEAR TO

"INFECTION CONTROL REQUIREMENTS BY ALL CLASSES" ON SHEET GI101.

B. AT LOCATION OF ALL CORES THROUGH FLOORS INSTALL RE-ENTERABLE FIRESTOP

ASSEMBLIES.

C. AT LOCATION OF CORES THROUGH RATED PARTITIONS INSTALL RE-ENTERABLE

FIRESTOP ASSEMBLIES (TYP.)

D. CONTRACTOR TO LOCATE EXISTING REINFORCING PRIOR TO CORING FOR

CONDUIT. DO NOT CUT REINFORCEMENT. CORES SHALL HAVE 4" CLEAR MINIMUM

BETWEEN THEM. ADJUST CORE LOCATIONS AS NEEDED. AT LOCATIONS WITH

MORE THAN TWO (2) CORES PASSING THROUGH A C.M.U. WALL, SPACE CORES AT

16" MINIMUM.

GENERAL PLAN NOTES

CEILING LEGEND

ARCHITECTURAL - BUILDING 1 -

BASEMENT LEVEL PLAN

DA JM

A-B01-100

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

K:

\C

C G

_P R

O

JE

C

TS

\2

1\

-1

T op ek a

EH

R M

C

1R

\4

- D es

D oc s\

2- D ra w in gs

\W O

R

KI

N G

\A ut oC

AD

\A -B

-1

.d w g

/6

/2

8:

:2

AM

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE

UPGRADES

COLMERY O'NEIL VA HEALTH CARE

21-116

Revisions: Date:

www. bancroft-ae.com

3300 Dundee RD.

Northbrook, IL 60062

T: 847.952.9362

35% SCHEMATIC DESIGN SUBMISSION 07-12-22

95% CONSTRUCTION DOCUMENTS SUBMISSION 10-31-23

100% FINAL BID DOCUMENT SUBMISSION

11/28/2023

12-19-23

Bancroft Project No: 21-116

VA REVIEW ONLY - NOT FOR CONSTRUCTION

35% SCHEMATIC DESIGN SUBMISSION R1 09-21-22

35% SUBMITTAL II 06-13-23

65% DESIGN DEVELOPMENT SUBMITTAL 09-12-23

B3 C20A

A19A

C7B

A13

MATERIAL DESCRIPTION MATERIAL LOCATION

9” x 9” Various Color Floor Tile

C7B, C125, C212, A233A, B325A, A554, A601, A601B, A618A

12” x 12” Brown Floor Tile and Mastic

A234, beneath raised floor

Yellow Sheet Vinyl Flooring

C302

Cement Board Radiator Cabinet Backing

A13, A127A, B119, C125, A232A, A233A, A234, A235, A328, B226A, B325A, C303, A432, B402, C402, A525, C503, A601, A601A, A604, A618

BUILDING 01: ACM & LBP SURVEY

SEE REPORT 8/16/2022 FOR DETAILS

*A19A, B3, C20A*

*ASSUME SIMILAR CONDITIONS AT THESE LOCATIONS

NOTE: FOR ROOM LOCATIONS OR SPCAES REQUIRING

ACM/LBP MITIGATION WITH DEMOLITION OF WALLS FOR

EXPANSION AND/OR A SUB-DIVISION SPACE, ASSUME

ADJACENT AREAS/ROOMS EFFECTED WILL REQUIRE

ACM/LBP MITIGATION TO THE EXTENT THE ADJACENT

ROOM IS EFFECTED BY NEW CONSTRUCTION - TYPICAL

AT ALL BUILDINGS RELATED TO THSI CONSTRUCTION

PROJECTS

Building 01 - LBP Survey

• Metal window frame in room A235 – tan paint

• Metal window sill in room A328 – brown paint

• Glazing on ceramic wall tile in rooms C208A, A601A, A604B and A618B – brown glazing

• Glazing on concrete wall blocks in room C303 – blue glazing

GENERAL NOTES

A. FOR GENERAL NOTES AND LEGENDS REFER TO SHEET A001.

B. FOR GENERAL INFECTION CONTROL NOTES AND DETAILS REFER TO SHEET GI101.

C. FOR FINISH SCHEDULE REFER TO SHEET AF-601.

D. EXISTING IT/TR/OI&T ROOMS TO REMAIN ACTIVE DURING CONSTRUCTION. G.C. TO PROTECT EQUIPMENT DURING CONSTRUCTION WITH VISQUEEN. CONTRACTOR TO ENSURE CONTINUOUS

OPERATION OF EQUIPMENT.

E. NOT ALL KEY NOTES APPLY TO ALL PLAN SHEETS. G.C. TO APPLY ONLY AS INDICATED PER EACH SHEET.

F. MAINTAIN A 4 ' - 0" CLEAR PATH OF TRAVEL IN THE CORRIDORS AT ALL TIMES.

G. ALL WORK TO BE PERFORMED AS PART OF TR MODIFICATION SHALL BE CONSIDERED AS TYPE IV AND FOLLOW "INFECTION CONTROL PRECAUTIONS FOR CLASS IV" ON SHEET GI101.

H. APPLY FIRE RATED SEALANT TO ALL EXISTING AND NEW PENETRATIONS IN EXISTING WALLS TO MAKE EXISTING WALLS A 1 HR ASSEMBLY. BASIS OF DESIGN FOR 1 HR WALL IS UL 419 ASSEMBLY.

I. ALL EXISTING WALLS WITH TR'S ARE TO BE FULLY PATCHED & PREPPED TO A LIKE NEW APPEARANCE BEFORE RECEIVING NEW PLYWOOD PANELS.

J. IN ALL EXISTING OI&T AND IRM ROOMS TO BE CONVERTED TO TR'S - ALL EXISTING PLYWOOD PANELS TO BE REMOVED A WALLS PATCHED AND PREPPED TO RECEIVE PAINT AND NEW PLYWOOD

PANELS.

CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.

RATED PARTITION LEGEND

1. INSTALL TEMPORARY FLAME RESISTANT CONSTRUCTION PANELS WITH DOOR ENTRY. BASIS

OF DESIGN IS EDGE GUARD.

2. SUPPLY AND INSTALL WALK OFF MAT(S). SEE DETAILS ON SHEET GI101.

3. EXISTING HANDRAIL, WALL BASE AND CARPET TO BE MODIFIED TO ACCEPT NEW DOOR.

4. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY. INFILL WALL WITH

METAL STUDS AND DRYWALL. ALIGN WITH EXISTING WALLS, PATCH, LEVEL AND FINISH TO

MATCH EXISTING WALL FINISH.

5. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY FOR INSTALLATION OF

NEW DOOR AND FRAME. PORTIONS OF EXISTING WALL TO BE DEMOLISHED TO RECEIVE NEW

LARGER SIZE DOOR AND FRAME ASSEMBLY. PATCH ADJACENT WALLS TO MATCH ADJACENT

CONDITIONS. RELOCATE ALL WALL MOUNTED ITEMS INCLUDING ROOM SIGNAGE, CHAIR

RAILS, CORNER GUARDS AND WALL MOUNTED ADJACENT TO EXISTING CORRIDOR DOOR AND

REINSTALL AT NEW DOOR LOCATION.

6. REMOVE EXISTING DOOR, FRAME AND HARDWARE. PREPARE WALL CONSTRUCTION AT

OPENING FOR NEW FRAME.

7. REMOVE GLASS FROM WINDOW SYSTEM AT THIS LOCATION. PREPARE WINDOW SYSTEM TO

RECEIVE INFILL AS NOTED IN NEW WORK SCOPE.

8. REMOVE EXISTING BASE AND/OR WALL CABINETS, COUNTERTOP, AND ASSOCIATE

COMPONENTS/EQUIPMENT COMPLETE. CAP ANY ASSOCIATED PLUMBING AT SOURCE, REFER

TO PLUMBING DRAWINGS.

9. REMOVE ALL EXISTING TELECOMMUNICATIONS AND ASSOCIATED ELECTRICAL EQUIPMENT

WITHIN EXISTING DATA CENTER UPON COMPLETION OF INFRASTRUCTURE UPGRADES

OUTLINED WITHIN THESE DOCUMENTS. RETURN ALL EQUIPMENT TO THE VA UNLESS

OTHERWISE NOTED.

10. PROTECT EXISTING EQUIPMENT CONTROLS BOX DURING CONSTRUCTION. RECONFIGURE AS

REQUIRED TO ALLOW FOR NEW WALL OPENING.

11. DEMO EXISTING WALL FOR FIRE EXTINGUISHER CABINET. REFER TO FLOOR PLAN KEYNOTE

#11. MODIFY EXISTING WALL NOUNTED ASSEMBLIES TO ALLOW FOR CABINET INSTALLATION.

12. G.C. TO CAREFULLY REMOVE EXISTING WINDOW TREATMENT AND TURN OVER TO VA.

13. REMOVE EXISTING WALL BASE AND EXISTING FLOORING (I.E. CARPET, LAMINATE FLOORING, VCT) TO EXISTING CONCRETE. SCRAPE CLEAN AND REMOVE ALL ASSOCIATED ADHESIVE.

PREP AND LEVEL EXISTING FLOORING TO RECEIVE NEW FINISH PER MANUFACURES

REQUIRMENT.

14. REMOVE ANY WALL MOUNTED ITEMS, EQUIPMENT, FURNITURE AND ASSOCIATED

COMPONENTS COMPLETE. CONTRACTOR TO ALLOW VA RIGHT OF FIRST REFUSAL OF ANY

REMOVED ITEMS.

DEMOLITION PLAN KEYNOTESX

1. FINISH WALL CORNER TO CORNER AND FLOOR TO CEILING. PRIOR TO PAINTING THE ENTIRE WALL SURFACE WITH (1) FINISH COAT OF PAINT, PROVIDE (1) PRIME COAT AND (2) FINISH

COATS OVER PATCHED/REPAIRED WALL SURFACES.

2. INSTALL NEW HANDRAIL, NEW CRASH RAIL AND WALL BASE TO CREATE LONG CONTINUOUS

RUN. EXTEND HANDRAIL, CRASH RAIL AND WALL BASE TO NEXT ASSEMBLY JOINT. FOR

DETAILS SEE SHEET A-502.

3. EXISTING GLAZING TO REMAIN. BACK-PAINT GLASS ON INSIDE OF GLAZING. PAINT BLACK

UNLESS OTHERWISE NOTED BY VA.

4. PATCH FLOOR AND PROVIDE NEW WALL BASE AS REQUIRED TO MATCH EXISTING CONDITIONS.

5. PROVIDE INSULATED ALUMINUM PANEL WITHIN WINDOW SYSTEM TO REPLACE PREVIOUS

GLASS PANEL. ALUMINUM FINISH SHALL MATCH WINDOW SYSTEM.

6. INSTALL TELECOMMUNICATIONS ENCLOSURE. SEE ELECTRICAL AND TECHNOLOGY DRAWINGS

FOR ADDITIONAL INFORMATION.

7. NEW PARTITION AS NOTED. ALIGN PARTITION WITH EXISTING WINDOW MULLION.

8. PATCH WALLS AS REQUIRED TO MATCH ADJACENT WALLS TO REMAIN AFTER DEMOLITION OF

NOTED COMPONENTS.

9. PATCH AND PAINT ALL WALLS TO LIKE NEW CONDITION. PAINT COLOR SHALL MATCH EXISTING

CONDITIONS.

10. INFILL WALL TO MATCH ADJACENT WALL CONSTRUCTION, INCLUDING FIRE RATING WHERE

REQUIRED.

11. FIRE EXTINGUISHER CABINET & CLEAN AGENT TYPE FIRE EXTINGUISHER MOUNTED 48” A.F.F.

TO CENTERLINE OF HANDLE. SEE DETAIL 1/A502. PATCH SURROUNDING WALLS.

FLOOR PLAN KEYNOTES

CEILING PLAN KEYNOTESX

X

FLOOR PLAN LEGEND

4'X8' AC GRADE 3/4" TRADE SIZE FIRE RATED PLYWOOD BACKBOARD PAINTED HIGH GLOSS WHITE WITH (2) COATS OF FIRE RESISTANT PAINT FOR SERVICE PROVIDER /SECURITY/VIDEO/ETC. AROUND PERIMETER WALLS OF TRS AND ENTRANCE ROOMS AS SHOWN. ENSURE THAT FIRE RATING STAMP IS TO REMAIN UNCOVERED BY PAINT.

DEMO CEILING KEYNOTESX

D1. REMOVE EXISTING CEILING GRID TO EXTENT REQUIRED TO COMPLETE WORK SCOPE AND

ACCOMMODATE INSTALLATION OF NEW PARTITIONS. SUPPORT EXISTING CEILING . SALVAGE

CEILING TILES FOR REINSTALLATION. RETURN UNUSED CEILING TILES TO VA FOR STORAGE.

D2. REMOVE EXISTING GYPSUM BOARD CEILING AND FRAMING ABOVE.

D3. REMOVE EXISTING LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS FOR FULL SCOPE OF

WORK RELATED TO ELECTRICAL DEMOLITION AND REWORK.

C1. INSTALL NEW CEILING GRID AND EDGE ANGLE. INSTALL SALVAGED CEILING TILES TO

MATCH EXISTING ADJACENT CONDITIONS. INSTALL NEW CEILING TILES WHERE SALVAGED

TILES DO NOT MATCH.

C2. INFILL CEILING TO MATCH ADJACENT EXISTING CEILING TO REMAIN.

C3. REPOSITION EXISTING LIGHT FIXTURES CENTERED IN ROOM AND WITHIN CEILING GRID.

C4. EXPOSED CEILING.

A

OFFICE

A19A

TR

A19A

A19D

A-19A

D1

B

B

OFFICE

A19A

TR

A19A

A19D STORAGE

B3

STORAGE

B3A

STORAGE

B20

CORRIDOR

C02

TR

B3

STORAGE

B3A

STORAGE

B20

CORRIDOR

C02

B

B

B

B3

D A

STORAGE

B3

STORAGE

B3A

STORAGE

B20

CORRIDOR

C02

TR

B3

STORAGE

B3A

STORAGE

B20

CORRIDOR

C02

ARCHITECTURAL - BUILDING 1 -

BASEMENT LEVEL - ENLARGED PLANS

DA JM

A-B01-401

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

K:

\C

C G

_P R

O

JE

C

TS

\2

1\

-1

T op ek a

EH

R M

C

1R

\4

- D es

D oc s\

2- D ra w in gs

\W O

R

KI

N G

\A ut oC

AD

\A -B

-4

.d w g

/7

/2

:0 3:

P

M

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE

UPGRADES

COLMERY O'NEIL VA HEALTH CARE

21-116

Revisions: Date:

www. bancroft-ae.com

3300 Dundee RD.

Northbrook, IL 60062

T: 847.952.9362

35% SCHEMATIC DESIGN SUBMISSION 07-12-22

95% CONSTRUCTION DOCUMENTS SUBMISSION 10-31-23

100% FINAL BID DOCUMENT SUBMISSION

11/28/2023

12-19-23

Bancroft Project No: 21-116

VA REVIEW ONLY - NOT FOR CONSTRUCTION

35% SCHEMATIC DESIGN SUBMISSION R1 09-21-22

35% SUBMITTAL II 06-13-23

65% DESIGN DEVELOPMENT SUBMITTAL 09-12-23

B. FOR GENERAL INFECTION CONTROL NOTES AND DETAILS REFER TO SHEET GI101.

C. FOR FINISH SCHEDULE REFER TO SHEET AF-601.

D. EXISTING IT/TR/OI&T ROOMS TO REMAIN ACTIVE DURING CONSTRUCTION. G.C. TO PROTECT EQUIPMENT DURING CONSTRUCTION WITH VISQUEEN. CONTRACTOR TO ENSURE CONTINUOUS

OPERATION OF EQUIPMENT.

E. NOT ALL KEY NOTES APPLY TO ALL PLAN SHEETS. G.C. TO APPLY ONLY AS INDICATED PER EACH SHEET.

F. MAINTAIN A 4 ' - 0" CLEAR PATH OF TRAVEL IN THE CORRIDORS AT ALL TIMES.

G. ALL WORK TO BE PERFORMED AS PART OF TR MODIFICATION SHALL BE CONSIDERED AS TYPE IV AND FOLLOW "INFECTION CONTROL PRECAUTIONS FOR CLASS IV" ON SHEET GI101.

H. APPLY FIRE RATED SEALANT TO ALL EXISTING AND NEW PENETRATIONS IN EXISTING WALLS TO MAKE EXISTING WALLS A 1 HR ASSEMBLY. BASIS OF DESIGN FOR 1 HR WALL IS UL 419 ASSEMBLY.

I. ALL EXISTING WALLS WITH TR'S ARE TO BE FULLY PATCHED & PREPPED TO A LIKE NEW APPEARANCE BEFORE RECEIVING NEW PLYWOOD PANELS.

J. IN ALL EXISTING OI&T AND IRM ROOMS TO BE CONVERTED TO TR'S - ALL EXISTING PLYWOOD PANELS TO BE REMOVED A WALLS PATCHED AND PREPPED TO RECEIVE PAINT AND NEW PLYWOOD

PANELS.

RATED PARTITION LEGEND

1. INSTALL TEMPORARY FLAME RESISTANT CONSTRUCTION PANELS WITH DOOR ENTRY. BASIS

OF DESIGN IS EDGE GUARD.

2. SUPPLY AND INSTALL WALK OFF MAT(S). SEE DETAILS ON SHEET GI101.

3. EXISTING HANDRAIL, WALL BASE AND CARPET TO BE MODIFIED TO ACCEPT NEW DOOR.

4. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY. INFILL WALL WITH

METAL STUDS AND DRYWALL. ALIGN WITH EXISTING WALLS, PATCH, LEVEL AND FINISH TO

MATCH EXISTING WALL FINISH.

5. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY FOR INSTALLATION OF

NEW DOOR AND FRAME. PORTIONS OF EXISTING WALL TO BE DEMOLISHED TO RECEIVE NEW

LARGER SIZE DOOR AND FRAME ASSEMBLY. PATCH ADJACENT WALLS TO MATCH ADJACENT

CONDITIONS. RELOCATE ALL WALL MOUNTED ITEMS INCLUDING ROOM SIGNAGE, CHAIR

RAILS, CORNER GUARDS AND WALL MOUNTED ADJACENT TO EXISTING CORRIDOR DOOR AND

REINSTALL AT NEW DOOR LOCATION.

6. REMOVE EXISTING DOOR, FRAME AND HARDWARE. PREPARE WALL CONSTRUCTION AT

OPENING FOR NEW FRAME.

7. REMOVE GLASS FROM WINDOW SYSTEM AT THIS LOCATION. PREPARE WINDOW SYSTEM TO

RECEIVE INFILL AS NOTED IN NEW WORK SCOPE.

8. REMOVE EXISTING BASE AND/OR WALL CABINETS, COUNTERTOP, AND ASSOCIATE

COMPONENTS/EQUIPMENT COMPLETE. CAP ANY ASSOCIATED PLUMBING AT SOURCE, REFER

TO PLUMBING DRAWINGS.

9. REMOVE ALL EXISTING TELECOMMUNICATIONS AND ASSOCIATED ELECTRICAL EQUIPMENT

WITHIN EXISTING DATA CENTER UPON COMPLETION OF INFRASTRUCTURE UPGRADES

OUTLINED WITHIN THESE DOCUMENTS. RETURN ALL EQUIPMENT TO THE VA UNLESS

OTHERWISE NOTED.

10. PROTECT EXISTING EQUIPMENT CONTROLS BOX DURING CONSTRUCTION. RECONFIGURE AS

REQUIRED TO ALLOW FOR NEW WALL OPENING.

11. DEMO EXISTING WALL FOR FIRE EXTINGUISHER CABINET. REFER TO FLOOR PLAN KEYNOTE

#11. MODIFY EXISTING WALL NOUNTED ASSEMBLIES TO ALLOW FOR CABINET INSTALLATION.

12. G.C. TO CAREFULLY REMOVE EXISTING WINDOW TREATMENT AND TURN OVER TO VA.

13. REMOVE EXISTING WALL BASE AND EXISTING FLOORING (I.E. CARPET, LAMINATE FLOORING, VCT) TO EXISTING CONCRETE. SCRAPE CLEAN AND REMOVE ALL ASSOCIATED ADHESIVE.

PREP AND LEVEL EXISTING FLOORING TO RECEIVE NEW FINISH PER MANUFACURES

REQUIRMENT.

14. REMOVE ANY WALL MOUNTED ITEMS, EQUIPMENT, FURNITURE AND ASSOCIATED

COMPONENTS COMPLETE. CONTRACTOR TO ALLOW VA RIGHT OF FIRST REFUSAL OF ANY

REMOVED ITEMS.

DEMOLITION PLAN KEYNOTESX

1. FINISH WALL CORNER TO CORNER AND FLOOR TO CEILING. PRIOR TO PAINTING THE ENTIRE WALL SURFACE WITH (1) FINISH COAT OF PAINT, PROVIDE (1) PRIME COAT AND (2) FINISH

COATS OVER PATCHED/REPAIRED WALL SURFACES.

2. INSTALL NEW HANDRAIL, NEW CRASH RAIL AND WALL BASE TO CREATE LONG CONTINUOUS

RUN. EXTEND HANDRAIL, CRASH RAIL AND WALL BASE TO NEXT ASSEMBLY JOINT. FOR

DETAILS SEE SHEET A-502.

3. EXISTING GLAZING TO REMAIN. BACK-PAINT GLASS ON INSIDE OF GLAZING. PAINT BLACK

UNLESS OTHERWISE NOTED BY VA.

4. PATCH FLOOR AND PROVIDE NEW WALL BASE AS REQUIRED TO MATCH EXISTING CONDITIONS.

5. PROVIDE INSULATED ALUMINUM PANEL WITHIN WINDOW SYSTEM TO REPLACE PREVIOUS

GLASS PANEL. ALUMINUM FINISH SHALL MATCH WINDOW SYSTEM.

6. INSTALL TELECOMMUNICATIONS ENCLOSURE. SEE ELECTRICAL AND TECHNOLOGY DRAWINGS

FOR ADDITIONAL INFORMATION.

7. NEW PARTITION AS NOTED. ALIGN PARTITION WITH EXISTING WINDOW MULLION.

8. PATCH WALLS AS REQUIRED TO MATCH ADJACENT WALLS TO REMAIN AFTER DEMOLITION OF

NOTED COMPONENTS.

9. PATCH AND PAINT ALL WALLS TO LIKE NEW CONDITION. PAINT COLOR SHALL MATCH EXISTING

CONDITIONS.

10. INFILL WALL TO MATCH ADJACENT WALL CONSTRUCTION, INCLUDING FIRE RATING WHERE

REQUIRED.

11. FIRE EXTINGUISHER CABINET & CLEAN AGENT TYPE FIRE EXTINGUISHER MOUNTED 48” A.F.F.

TO CENTERLINE OF HANDLE. SEE DETAIL 1/A502. PATCH SURROUNDING WALLS.

FLOOR PLAN KEYNOTES

CEILING PLAN KEYNOTESX

X

FLOOR PLAN LEGEND

4'X8' AC GRADE 3/4" TRADE SIZE FIRE RATED PLYWOOD BACKBOARD PAINTED HIGH GLOSS WHITE WITH (2) COATS OF FIRE RESISTANT PAINT FOR SERVICE PROVIDER /SECURITY/VIDEO/ETC. AROUND PERIMETER WALLS OF TRS AND ENTRANCE ROOMS AS SHOWN. ENSURE THAT FIRE RATING STAMP IS TO REMAIN UNCOVERED BY PAINT.

DEMO CEILING KEYNOTESX

D1. REMOVE EXISTING CEILING GRID TO EXTENT REQUIRED TO COMPLETE WORK SCOPE AND

ACCOMMODATE INSTALLATION OF NEW PARTITIONS. SUPPORT EXISTING CEILING . SALVAGE

CEILING TILES FOR REINSTALLATION. RETURN UNUSED CEILING TILES TO VA FOR STORAGE.

D2. REMOVE EXISTING GYPSUM BOARD CEILING AND FRAMING ABOVE.

D3. REMOVE EXISTING LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS FOR FULL SCOPE OF

WORK RELATED TO ELECTRICAL DEMOLITION AND REWORK.

C1. INSTALL NEW CEILING GRID AND EDGE ANGLE. INSTALL SALVAGED CEILING TILES TO

MATCH EXISTING ADJACENT CONDITIONS. INSTALL NEW CEILING TILES WHERE SALVAGED

TILES DO NOT MATCH.

C2. INFILL CEILING TO MATCH ADJACENT EXISTING CEILING TO REMAIN.

C3. REPOSITION EXISTING LIGHT FIXTURES CENTERED IN ROOM AND WITHIN CEILING GRID.

C4. EXPOSED CEILING.

A

MECHANICAL

ROOM/STORAGE

C22

ADMINISTRATIVE

OFFICE

C23

OPEN OFFICE

C20

TR

C20A

MECHANICAL

ROOM/STORAGE

C22

ADMINISTRATIVE

OFFICE

C23

C-20A

D1

B

C-2 2B

D

MECHANICAL

ADMINISTRATIVE

OFFICE

C23

OPEN OFFICE

C20

TR

C20A

MECHANICAL

ROOM/STORAGE

C23

ARCHITECTURAL - BUILDING 1 -

BASEMENT LEVEL - ENLARGED PLAN

DA JM

A-B01-402

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

K:

\C

C G

_P R

O

JE

C

TS

\2

1\

-1

T op ek a

EH

R M

C

1R

\4

- D es

D oc s\

2- D ra w in gs

\W O

R

KI

N G

\A ut oC

AD

\A -B

-4

.d w g

/3

1/

:2 6:

A

M

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE

UPGRADES

COLMERY O'NEIL VA HEALTH CARE

21-116

Revisions: Date:

www. bancroft-ae.com

3300 Dundee RD.

Northbrook, IL 60062

T: 847.952.9362

35% SCHEMATIC DESIGN SUBMISSION 07-12-22

95% CONSTRUCTION DOCUMENTS SUBMISSION 10-31-23

100% FINAL BID DOCUMENT SUBMISSION

11/28/2023

12-19-23

Bancroft Project No: 21-116

VA REVIEW ONLY - NOT FOR CONSTRUCTION

35% SCHEMATIC DESIGN SUBMISSION R1 09-21-22

UP

UP

UP

UP

DN

UP

DN

UP

UPUP

UP

A

B

C

D

E

F

1 3 4 5 11 13 16 18 19 21 23 25 26 27 286 8 9

11.1

14 15

K

L

M

29 30

G

O

Q

S

T

U

V

P

S.2

S.1

Q.1

U.1

V.1

V.2

W.1

X

Y

8.26.36.2 10.19.3 12.111.2

2.1

3.1

4.1

3.8

Z.4

4.7 6.1 8.1 11.7

Z.3

Z.2

24 31 32

N

7 222010 12

18B 20B 22B 24B 24C

H

I

J

R

W

Z.1

22D

AC101A AC130

AC101B

AC101C

AC133

AC128

AC129 AC134 AC135

AC131

AC131

AC101D

AC136

B1-03C

AC119

B113

AC127A

AC127B

C100

AC100

AC101

AC104

A140

A141A128C

A1

B103 B105

C110C109C107 C108

C116F C116A

C116

C116B

C105

C104

C106

C115

A1

A143F

A121AA119A118

A117A

A116B

A116A

A120 A121 A121B

A115

A115H

A115A A115I

A115J

A115BA115C

A115G

A122

A115E

A121E A122F

A102G

A102A

A1

A102BA102C

A102D

A108

A109

AC101J

AC101I

AC101H

AC101G

A127 A127BA127A

C116C

C116D

C119

C120C124

C125

C121

C122

C123

C123BC123A

C126

C127

C1-02

A145

C117 C104F C116E C105E

A143

A102E A101E

C102C101A144 C103

A111

A112

A104A

A104

A106

A105A110

A136

B149B1

B116

B148

B147

B146

AC120A

AC120

A116HA116G

A116E A116F

A116D

A116C

A116

A107

A104B

A115D

AC119AC118AC115

AC112

AC112A

AC114

AC109

A135

B145

B133

B134

B136 B135

B131 B132B130

B138

B129

B139B140

B128

B127

B137

B126

B141

B124B119

B123E

B143 B142

B133AB120

B143E

B120F

AC135

AC110

AC111

AC121

AC116E

AC122

AC122A

AC125

AC106E

AC113

AC124

AC123

AC117

B118

A137

B117A

A134A

C113 C112C111

C114D

C114-E

C114B

C114C

C114C

C114-W

C1-03A103

B123 B125

A1-04 A1-03

A140E

A134

A128B

A128D

A128A

AC105AC106

A1

A

A129

A128H A128G

AC108

AC1-5

B114

B106B107

B108

B113

B109A B109

B111

B1

B115

B104

B116C

B116D B1-03

A1-01

A101

A138

A142A

AC101K

B1-04B1-01

B1-02

A101A

A101G A101C

A113

B101

A101D

A141E

C1-01

C114T

A114

AC147 AC148 AC149 AC150 AC151 AC152 AC153 AC154 AC155 AC156

AC158 AC157

AC165AC164AC161

AC160

AC143 AC143A

AC145AC146

AC144 AC141 AC162 AC163 AC166

AC167

AC

1-

AC

1-

AC

1-

A615P

A6

Q

AC1-2

AC159

A1-02

A1-E1

A1-E2

A1-E3 A1-E4

A101H

A101J

AC134A AC136AAC135A

AC134C B1-03D

B116A

1&2

FP-01-412

3&4 M-01-411

1,2,3&4 A-01-411

5,6,7&8 A-01-411

1,2,3&4 A-01-412

1&2 M-01-412

1&2

FP-01-413

3&4 M-01-411

1&2

FP-01-411

RATED PARTITION LEGEND

CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.

1 HR FIRE BARRIER

2 HR FIRE BARRIER

SMOKE BARRIER

1 HR FIRE BARRIER (EXISTING)

2 HR FIRE BARRIER (EXISTING)

SMOKE BARRIER (EXISTING)

1. REMOVE AND STORE CEILING TILES IN THIS AREA AS REQUIRED FOR MECHANICAL

DUCTWORK, PIPING, ELECTRICAL CONDUIT, TECHNOLOGY EQUIPMENT AND/OR

SECURITY INSTALLATION. REINSTALL TILES AND GRID WHEN WORK IS COMPLETED.

REPLACE ANY DAMAGED TILES AND GRIDS TO MATCH EXISTING. G.C. SHALL

TEMPORARILY ERECT A SUSPENDED PLASTIC BARRIER 6 MIL AROUND AREA OF

CEILING WORK TO BE PERFORMED DURING ONE SHIFT AND G.C. SHALL REMOVE

SUSPENDED PLASTIC BARRIER AT THE END OF SHIFT. G.C. SHALL MOP CLEAN THIS

AREA OF WORK. PRIOR TO TURNING OVER AREA TO VA. AFTER WORK HOURS WILL

REQUIRE ADDITIONAL COORDINATION WITH THE VA.

A. REFER TO TECHNOLOGY AND ELECTRICAL FOR FULL REQUIRED INSTALLATION

AND DEMOLITION WORK

B. ALL EXISTING LIGHTING, CONDUIT, DUCTWORK, MECHANICAL GRILLS, &

SPRINKLER HEADS TO REMAIN IN EXISTING LOCATIONS AND PROTECTED

UNLESS OTHERWISE NOTED.

C. ANY ELECTRICAL FIXTURES AND DEVICES THAT ARE NOT IDENTIFIED ON THESE

DRAWINGS IN THE AREAS OF CEILING DEMOLITION, ARE TO BE CAREFULLY

REMOVED FROM THE CEILING, PROTECTED, TEMPORARILY HUNG AND THEN

REATTACHED IN THE SAME LOCATIONS AS WHICH THEY WERE FOUND PRIOR TO

DEMOLITION.

D. CONTRACTOR TO CAREFULLY REMOVE SECTIONS OF EXISTING CEILING TILE TO

ALLOW FOR THE INSTALLATION OF ALL REQUIRED CONDUIT AND ELECTRICAL

EQUIPMENT PER CONTRACT DRAWINGS. CONTRACTOR SHALL REINSTALL

CEILING IN EXACT LOCATION. CONTRACTOR TO REPLACE ANY CEILING

GRID/TILES DAMAGED DURING CONSTRUCTION, MATCHING EXISTING. REFER TO

ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION.

E. IF A RATED ASSEMBLY IS NOT INSTALLED BY END OF SHIFT IT MUST BE

PROTECTED OVERNIGHT.

GENERAL DEMOLITION NOTES

CEILING DEMOLITION LEGEND

CEILING DEMOLITION KEY NOTESX

1. REPLACE EXISTING A,B&C TYPE FIRE EXTINGUISHER WITH CLEAN AGENT A,B&C

TYPE FIRE EXTINGUISHER.

2. INSTALL CLEAN AGENT A,B&C TYPE FIRE EXTINGUISHER IN SEMI-RECESSED

CABINET SET IN NEW GYP. BD. ON METAL STUD ASSEMBLY (1-HR RATED)

3. INSTALL CLEAN AGENT A,B&C TYPE FIRE EXTINGUISHER IN SEMI-RECESSED

CABINET IN EXISTING WALL WRAP CABINET IN TYPE 'X' GYPSUM BOARD.

FLOOR PLAN KEY NOTESX

KEYNOTE 11

A. ALL WORK ASSOCIATED WITH TEMPORARY CEILING REMOVAL AND INSTALLATION

OF CABLING SHALL BE CONSIDERED AS NO MORE HAZARDOUS THAN NORMAL

OPERATIONS. INFECTION CONTROL REQUIREMENTS FOR THIS WORK SHALL

INCLUDE "VISQUEEN" TYPE BARRIER AROUND WORK AND/OR INFECTION CONTROL

MODULES WITH VA STATION APPROVAL. CONTRACTOR SHALL ALSO ADHEAR TO

"INFECTION CONTROL REQUIREMENTS BY ALL CLASSES" ON SHEET GI101.

B. AT LOCATION OF ALL CORES THROUGH FLOORS INSTALL RE-ENTERABLE FIRESTOP

ASSEMBLIES.

C. AT LOCATION OF CORES THROUGH RATED PARTITIONS INSTALL RE-ENTERABLE

FIRESTOP ASSEMBLIES (TYP.)

D. CONTRACTOR TO LOCATE EXISTING REINFORCING PRIOR TO CORING FOR

CONDUIT. DO NOT CUT REINFORCEMENT. CORES SHALL HAVE 4" CLEAR MINIMUM

BETWEEN THEM. ADJUST CORE LOCATIONS AS NEEDED. AT LOCATIONS WITH

MORE THAN TWO (2) CORES PASSING THROUGH A C.M.U. WALL, SPACE CORES AT

16" MINIMUM.

GENERAL PLAN NOTES

CEILING LEGEND

ARCHITECTURAL - BUILDING 1 - LEVEL 1

PLAN

DA JM

A-B01-101

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

K:

\C

C G

_P R

O

JE

C

TS

\2

1\

-1

T op ek a

EH

R M

C

1R

\4

- D es

D oc s\

2- D ra w in gs

\W O

R

KI

N G

\A ut oC

AD

\A -B

-1

.d w g

/6

/2

9:

:0

AM

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE

UPGRADES

COLMERY O'NEIL VA HEALTH CARE

21-116

Revisions: Date:

www. bancroft-ae.com

3300 Dundee RD.

Northbrook, IL 60062

T: 847.952.9362

35% SCHEMATIC DESIGN SUBMISSION 07-12-22

95% CONSTRUCTION DOCUMENTS SUBMISSION 10-31-23

100% FINAL BID DOCUMENT SUBMISSION

11/28/2023

12-19-23

Bancroft Project No: 21-116

VA REVIEW ONLY - NOT FOR CONSTRUCTION

35% SCHEMATIC DESIGN SUBMISSION R1 09-21-22

35% SUBMITTAL II 06-13-23

65% DESIGN DEVELOPMENT SUBMITTAL 09-12-23

AC160

B116A A144

C125

B119

A127A

MATERIAL DESCRIPTION MATERIAL LOCATION

9” x 9” Various Color Floor Tile

C7B, C125, C212, A233A, B325A, A554, A601, A601B, A618A

12” x 12” Brown Floor Tile and Mastic

A234, beneath raised floor

Yellow Sheet Vinyl Flooring

C302

Cement Board Radiator Cabinet Backing

A13, A127A, B119, C125, A232A, A233A, A234, A235, A328, B226A, B325A, C303, A432, B402, C402, A525, C503, A601, A601A, A604, A618

BUILDING 01: ACM & LBP SURVEY

SEE REPORT 8/16/2022 FOR DETAILS

*A144, B116A, AC160*

*ASSUME SIMILAR CONDITIONS AT THESE LOCATIONS

*A144*

Building 01 - LBP Survey

• Metal window frame in room A235 – tan paint

• Metal window sill in room A328 – brown paint

• Glazing on ceramic wall tile in rooms C208A, A601A, A604B

B. FOR GENERAL INFECTION CONTROL NOTES AND DETAILS REFER TO SHEET GI101.

C. FOR FINISH SCHEDULE REFER TO SHEET AF-601.

D. EXISTING IT/TR/OI&T ROOMS TO REMAIN ACTIVE DURING CONSTRUCTION. G.C. TO PROTECT EQUIPMENT DURING CONSTRUCTION WITH VISQUEEN. CONTRACTOR TO ENSURE CONTINUOUS

OPERATION OF EQUIPMENT.

E. NOT ALL KEY NOTES APPLY TO ALL PLAN SHEETS. G.C. TO APPLY ONLY AS INDICATED PER EACH SHEET.

F. MAINTAIN A 4 ' - 0" CLEAR PATH OF TRAVEL IN THE CORRIDORS AT ALL TIMES.

G. ALL WORK TO BE PERFORMED AS PART OF TR MODIFICATION SHALL BE CONSIDERED AS TYPE IV AND FOLLOW "INFECTION CONTROL PRECAUTIONS FOR CLASS IV" ON SHEET GI101.

H. APPLY FIRE RATED SEALANT TO ALL EXISTING AND NEW PENETRATIONS IN EXISTING WALLS TO MAKE EXISTING WALLS A 1 HR ASSEMBLY. BASIS OF DESIGN FOR 1 HR WALL IS UL 419 ASSEMBLY.

I. ALL EXISTING WALLS WITH TR'S ARE TO BE FULLY PATCHED & PREPPED TO A LIKE NEW APPEARANCE BEFORE RECEIVING NEW PLYWOOD PANELS.

J. IN ALL EXISTING OI&T AND IRM ROOMS TO BE CONVERTED TO TR'S - ALL EXISTING PLYWOOD PANELS TO BE REMOVED A WALLS PATCHED AND PREPPED TO RECEIVE PAINT AND NEW PLYWOOD

PANELS.

1. INSTALL TEMPORARY FLAME RESISTANT CONSTRUCTION PANELS WITH DOOR ENTRY. BASIS

OF DESIGN IS EDGE GUARD.

2. SUPPLY AND INSTALL WALK OFF MAT(S). SEE DETAILS ON SHEET GI101.

3. EXISTING HANDRAIL, WALL BASE AND CARPET TO BE MODIFIED TO ACCEPT NEW DOOR.

4. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY. INFILL WALL WITH

METAL STUDS AND DRYWALL. ALIGN WITH EXISTING WALLS, PATCH, LEVEL AND FINISH TO

MATCH EXISTING WALL FINISH.

5. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY FOR INSTALLATION OF

NEW DOOR AND FRAME. PORTIONS OF EXISTING WALL TO BE DEMOLISHED TO RECEIVE NEW

LARGER SIZE DOOR AND FRAME ASSEMBLY. PATCH ADJACENT WALLS TO MATCH ADJACENT

CONDITIONS. RELOCATE ALL WALL MOUNTED ITEMS INCLUDING ROOM SIGNAGE, CHAIR

RAILS, CORNER GUARDS AND WALL MOUNTED ADJACENT TO EXISTING CORRIDOR DOOR AND

REINSTALL AT NEW DOOR LOCATION.

6. REMOVE EXISTING DOOR, FRAME AND HARDWARE. PREPARE WALL CONSTRUCTION AT

OPENING FOR NEW FRAME.

7. REMOVE GLASS FROM WINDOW SYSTEM AT THIS LOCATION. PREPARE WINDOW SYSTEM TO

RECEIVE INFILL AS NOTED IN NEW WORK SCOPE.

8. REMOVE EXISTING BASE AND/OR WALL CABINETS, COUNTERTOP, AND ASSOCIATE

COMPONENTS/EQUIPMENT COMPLETE. CAP ANY ASSOCIATED PLUMBING AT SOURCE, REFER

TO PLUMBING DRAWINGS.

9. REMOVE ALL EXISTING TELECOMMUNICATIONS AND ASSOCIATED ELECTRICAL EQUIPMENT

WITHIN EXISTING DATA CENTER UPON COMPLETION OF INFRASTRUCTURE UPGRADES

OUTLINED WITHIN THESE DOCUMENTS. RETURN ALL EQUIPMENT TO THE VA UNLESS

OTHERWISE NOTED.

10. PROTECT EXISTING EQUIPMENT CONTROLS BOX DURING CONSTRUCTION. RECONFIGURE AS

REQUIRED TO ALLOW FOR NEW WALL OPENING.

11. DEMO EXISTING WALL FOR FIRE EXTINGUISHER CABINET. REFER TO FLOOR PLAN KEYNOTE

#11. MODIFY EXISTING WALL NOUNTED ASSEMBLIES TO ALLOW FOR CABINET INSTALLATION.

12. G.C. TO CAREFULLY REMOVE EXISTING WINDOW TREATMENT AND TURN OVER TO VA.

13. REMOVE EXISTING WALL BASE AND EXISTING FLOORING (I.E. CARPET, LAMINATE FLOORING, VCT) TO EXISTING CONCRETE. SCRAPE CLEAN AND REMOVE ALL ASSOCIATED ADHESIVE.

PREP AND LEVEL EXISTING FLOORING TO RECEIVE NEW FINISH PER MANUFACURES

REQUIRMENT.

14. REMOVE ANY WALL MOUNTED ITEMS, EQUIPMENT, FURNITURE AND ASSOCIATED

COMPONENTS COMPLETE. CONTRACTOR TO ALLOW VA RIGHT OF FIRST REFUSAL OF ANY

REMOVED ITEMS.

DEMOLITION PLAN KEYNOTESX

1. FINISH WALL CORNER TO CORNER AND FLOOR TO CEILING. PRIOR TO PAINTING THE ENTIRE WALL SURFACE WITH (1) FINISH COAT OF PAINT, PROVIDE (1) PRIME COAT AND (2) FINISH

COATS OVER PATCHED/REPAIRED WALL SURFACES.

2. INSTALL NEW HANDRAIL, NEW CRASH RAIL AND WALL BASE TO CREATE LONG CONTINUOUS

RUN. EXTEND HANDRAIL, CRASH RAIL AND WALL BASE TO NEXT ASSEMBLY JOINT. FOR

DETAILS SEE SHEET A-502.

3. EXISTING GLAZING TO REMAIN. BACK-PAINT GLASS ON INSIDE OF GLAZING. PAINT BLACK

UNLESS OTHERWISE NOTED BY VA.

4. PATCH FLOOR AND PROVIDE NEW WALL BASE AS REQUIRED TO MATCH EXISTING CONDITIONS.

5. PROVIDE INSULATED ALUMINUM PANEL WITHIN WINDOW SYSTEM TO REPLACE PREVIOUS

GLASS PANEL. ALUMINUM FINISH SHALL MATCH WINDOW SYSTEM.

6. INSTALL TELECOMMUNICATIONS ENCLOSURE. SEE ELECTRICAL AND TECHNOLOGY DRAWINGS

FOR ADDITIONAL INFORMATION.

7. NEW PARTITION AS NOTED. ALIGN PARTITION WITH EXISTING WINDOW MULLION.

8. PATCH WALLS AS REQUIRED TO MATCH ADJACENT WALLS TO REMAIN AFTER DEMOLITION OF

NOTED COMPONENTS.

9. PATCH AND PAINT ALL WALLS TO LIKE NEW CONDITION. PAINT COLOR SHALL MATCH EXISTING

CONDITIONS.

10. INFILL WALL TO MATCH ADJACENT WALL CONSTRUCTION, INCLUDING FIRE RATING WHERE

REQUIRED.

11. FIRE EXTINGUISHER CABINET & CLEAN AGENT TYPE FIRE EXTINGUISHER MOUNTED 48” A.F.F.

TO CENTERLINE OF HANDLE. SEE DETAIL 1/A502. PATCH SURROUNDING WALLS.

FLOOR PLAN KEYNOTES

CEILING PLAN KEYNOTESX

X

FLOOR PLAN LEGEND

4'X8' AC GRADE 3/4" TRADE SIZE FIRE RATED PLYWOOD BACKBOARD PAINTED HIGH GLOSS WHITE WITH (2) COATS OF FIRE RESISTANT PAINT FOR SERVICE PROVIDER /SECURITY/VIDEO/ETC. AROUND PERIMETER WALLS OF TRS AND ENTRANCE ROOMS AS SHOWN. ENSURE THAT FIRE RATING STAMP IS TO REMAIN UNCOVERED BY PAINT.

DEMO CEILING KEYNOTESX

D1. REMOVE EXISTING CEILING GRID TO EXTENT REQUIRED TO COMPLETE WORK SCOPE AND

ACCOMMODATE INSTALLATION OF NEW PARTITIONS. SUPPORT EXISTING CEILING . SALVAGE

CEILING TILES FOR REINSTALLATION. RETURN UNUSED CEILING TILES TO VA FOR STORAGE.

D2. REMOVE EXISTING GYPSUM BOARD CEILING AND FRAMING ABOVE.

D3. REMOVE EXISTING LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS FOR FULL SCOPE OF

WORK RELATED TO ELECTRICAL DEMOLITION AND REWORK.

C1. INSTALL NEW CEILING GRID AND EDGE ANGLE. INSTALL SALVAGED CEILING TILES TO

MATCH EXISTING ADJACENT CONDITIONS. INSTALL NEW CEILING TILES WHERE SALVAGED

TILES DO NOT MATCH.

C2. INFILL CEILING TO MATCH ADJACENT EXISTING CEILING TO REMAIN.

C3. REPOSITION EXISTING LIGHT FIXTURES CENTERED IN ROOM AND WITHIN CEILING GRID.

C4. EXPOSED CEILING.

A

TELE/DATA

AC160

EXAM

AC162

EXAM

AC141

STATION

AC159

TR

AC160

EXAM

AC162

EXAM

AC141

STATION

AC159

AC-160

B

D1

B

D1

D

TELE/DATA

AC160

EXAMEXAM

STATION

AC159

TR

AC160

EXAM

AC162

EXAM

AC141

NURSE

STATION

AC159

CORRIDOR

B103

AC131

EXAM # 19

AC119

CLEAN

UTILITY

B116C CORRIDOR

B103

EXAM # 19

TR

B116A

CLEAN

UTILITY

B116C

B

B

D1

TR

B116A

CLEAN

UTILITY

B116C

CLEAN

UTILITY

B116C

ARCHITECTURAL - BUILDING 1 - LEVEL 1

- ENLARGED PLANS

DA JM

A-B01-411

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

K:

\C

C G

_P R

O

JE

C

TS

\2

1\

-1

T op ek a

EH

R M

C

1R

\4

- D es

D oc s\

2- D ra w in gs

\W O

R

KI

N G

\A ut oC

AD

\A -B

-4

.d w g

/3

1/

:3 9:

A

M

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE

UPGRADES

COLMERY O'NEIL VA HEALTH CARE

21-116

Revisions: Date:

www. bancroft-ae.com

3300 Dundee RD.

Northbrook, IL 60062

T: 847.952.9362

35% SCHEMATIC DESIGN SUBMISSION 07-12-22

95% CONSTRUCTION DOCUMENTS SUBMISSION 10-31-23

100% FINAL BID DOCUMENT SUBMISSION

11/28/2023

12-19-23

Bancroft Project No: 21-116

VA REVIEW ONLY - NOT FOR CONSTRUCTION

35% SCHEMATIC DESIGN SUBMISSION R1 09-21-22

B. FOR GENERAL INFECTION CONTROL NOTES AND DETAILS REFER TO SHEET GI101.

C. FOR FINISH SCHEDULE REFER TO SHEET AF-601.

D. EXISTING IT/TR/OI&T ROOMS TO REMAIN ACTIVE DURING CONSTRUCTION. G.C. TO PROTECT EQUIPMENT DURING CONSTRUCTION WITH VISQUEEN. CONTRACTOR TO ENSURE CONTINUOUS

OPERATION OF EQUIPMENT.

E. NOT ALL KEY NOTES APPLY TO ALL PLAN SHEETS. G.C. TO APPLY ONLY AS INDICATED PER EACH SHEET.

F. MAINTAIN A 4 ' - 0" CLEAR PATH OF TRAVEL IN THE CORRIDORS AT ALL TIMES.

G. ALL WORK TO BE PERFORMED AS PART OF TR MODIFICATION SHALL BE CONSIDERED AS TYPE IV AND FOLLOW "INFECTION CONTROL PRECAUTIONS FOR CLASS IV" ON SHEET GI101.

H. APPLY FIRE RATED SEALANT TO ALL EXISTING AND NEW PENETRATIONS IN EXISTING WALLS TO MAKE EXISTING WALLS A 1 HR ASSEMBLY. BASIS OF DESIGN FOR 1 HR WALL IS UL 419 ASSEMBLY.

I. ALL EXISTING WALLS WITH TR'S ARE TO BE FULLY PATCHED & PREPPED TO A LIKE NEW APPEARANCE BEFORE RECEIVING NEW PLYWOOD PANELS.

J. IN ALL EXISTING OI&T AND IRM ROOMS TO BE CONVERTED TO TR'S - ALL EXISTING PLYWOOD PANELS TO BE REMOVED A WALLS PATCHED AND PREPPED TO RECEIVE PAINT AND NEW PLYWOOD

PANELS.

1. INSTALL TEMPORARY FLAME RESISTANT CONSTRUCTION PANELS WITH DOOR ENTRY. BASIS

OF DESIGN IS EDGE GUARD.

2. SUPPLY AND INSTALL WALK OFF MAT(S). SEE DETAILS ON SHEET GI101.

3. EXISTING HANDRAIL, WALL BASE AND CARPET TO BE MODIFIED TO ACCEPT NEW DOOR.

4. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY. INFILL WALL WITH

METAL STUDS AND DRYWALL. ALIGN WITH EXISTING WALLS, PATCH, LEVEL AND FINISH TO

MATCH EXISTING WALL FINISH.

5. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY FOR INSTALLATION OF

NEW DOOR AND FRAME. PORTIONS OF EXISTING WALL TO BE DEMOLISHED TO RECEIVE NEW

LARGER SIZE DOOR AND FRAME ASSEMBLY. PATCH ADJACENT WALLS TO MATCH ADJACENT

CONDITIONS. RELOCATE ALL WALL MOUNTED ITEMS INCLUDING ROOM SIGNAGE, CHAIR

RAILS, CORNER GUARDS AND WALL MOUNTED ADJACENT TO EXISTING CORRIDOR DOOR AND

REINSTALL AT NEW DOOR LOCATION.

6. REMOVE EXISTING DOOR, FRAME AND HARDWARE. PREPARE WALL CONSTRUCTION AT

OPENING FOR NEW FRAME.

7. REMOVE GLASS FROM WINDOW SYSTEM AT THIS LOCATION. PREPARE WINDOW SYSTEM TO

RECEIVE INFILL AS NOTED IN NEW WORK SCOPE.

8. REMOVE EXISTING BASE AND/OR WALL CABINETS, COUNTERTOP, AND ASSOCIATE

COMPONENTS/EQUIPMENT COMPLETE. CAP ANY ASSOCIATED PLUMBING AT SOURCE, REFER

TO PLUMBING DRAWINGS.

9. REMOVE ALL EXISTING TELECOMMUNICATIONS AND ASSOCIATED ELECTRICAL EQUIPMENT

WITHIN EXISTING DATA CENTER UPON COMPLETION OF INFRASTRUCTURE UPGRADES

OUTLINED WITHIN THESE DOCUMENTS. RETURN ALL EQUIPMENT TO THE VA UNLESS

OTHERWISE NOTED.

10. PROTECT EXISTING EQUIPMENT CONTROLS BOX DURING CONSTRUCTION. RECONFIGURE AS

REQUIRED TO ALLOW FOR NEW WALL OPENING.

11. DEMO EXISTING WALL FOR FIRE EXTINGUISHER CABINET. REFER TO FLOOR PLAN KEYNOTE

#11. MODIFY EXISTING WALL NOUNTED ASSEMBLIES TO ALLOW FOR CABINET INSTALLATION.

12. G.C. TO CAREFULLY REMOVE EXISTING WINDOW TREATMENT AND TURN OVER TO VA.

13. REMOVE EXISTING WALL BASE AND EXISTING FLOORING (I.E. CARPET, LAMINATE FLOORING, VCT) TO EXISTING CONCRETE. SCRAPE CLEAN AND REMOVE ALL ASSOCIATED ADHESIVE.

PREP AND LEVEL EXISTING FLOORING TO RECEIVE NEW FINISH PER MANUFACURES

REQUIRMENT.

14. REMOVE ANY WALL MOUNTED ITEMS, EQUIPMENT, FURNITURE AND ASSOCIATED

COMPONENTS COMPLETE. CONTRACTOR TO ALLOW VA RIGHT OF FIRST REFUSAL OF ANY

REMOVED ITEMS.

DEMOLITION PLAN KEYNOTESX

1. FINISH WALL CORNER TO CORNER AND FLOOR TO CEILING. PRIOR TO PAINTING THE ENTIRE WALL SURFACE WITH (1) FINISH COAT OF PAINT, PROVIDE (1) PRIME COAT AND (2) FINISH

COATS OVER PATCHED/REPAIRED WALL SURFACES.

2. INSTALL NEW HANDRAIL, NEW CRASH RAIL AND WALL BASE TO CREATE LONG CONTINUOUS

RUN. EXTEND HANDRAIL, CRASH RAIL AND WALL BASE TO NEXT ASSEMBLY JOINT. FOR

DETAILS SEE SHEET A-502.

3. EXISTING GLAZING TO REMAIN. BACK-PAINT GLASS ON INSIDE OF GLAZING. PAINT BLACK

UNLESS OTHERWISE NOTED BY VA.

4. PATCH FLOOR AND PROVIDE NEW WALL BASE AS REQUIRED TO MATCH EXISTING CONDITIONS.

5. PROVIDE INSULATED ALUMINUM PANEL WITHIN WINDOW SYSTEM TO REPLACE PREVIOUS

GLASS PANEL. ALUMINUM FINISH SHALL MATCH WINDOW SYSTEM.

6. INSTALL TELECOMMUNICATIONS ENCLOSURE. SEE ELECTRICAL AND TECHNOLOGY DRAWINGS

FOR ADDITIONAL INFORMATION.

7. NEW PARTITION AS NOTED. ALIGN PARTITION WITH EXISTING WINDOW MULLION.

8. PATCH WALLS AS REQUIRED TO MATCH ADJACENT WALLS TO REMAIN AFTER DEMOLITION OF

NOTED COMPONENTS.

9. PATCH AND PAINT ALL WALLS TO LIKE NEW CONDITION. PAINT COLOR SHALL MATCH EXISTING

CONDITIONS.

10. INFILL WALL TO MATCH ADJACENT WALL CONSTRUCTION, INCLUDING FIRE RATING WHERE

REQUIRED.

11. FIRE EXTINGUISHER CABINET & CLEAN AGENT TYPE FIRE EXTINGUISHER MOUNTED 48” A.F.F.

TO CENTERLINE OF HANDLE. SEE DETAIL 1/A502. PATCH SURROUNDING WALLS.

FLOOR PLAN KEYNOTES

CEILING PLAN KEYNOTESX

X

FLOOR PLAN LEGEND

4'X8' AC GRADE 3/4" TRADE SIZE FIRE RATED PLYWOOD BACKBOARD PAINTED HIGH GLOSS WHITE WITH (2) COATS OF FIRE RESISTANT PAINT FOR SERVICE PROVIDER /SECURITY/VIDEO/ETC. AROUND PERIMETER WALLS OF TRS AND ENTRANCE ROOMS AS SHOWN. ENSURE THAT FIRE RATING STAMP IS TO REMAIN UNCOVERED BY PAINT.

DEMO CEILING KEYNOTESX

D1. REMOVE EXISTING CEILING GRID TO EXTENT REQUIRED TO COMPLETE WORK SCOPE AND

ACCOMMODATE INSTALLATION OF NEW PARTITIONS. SUPPORT EXISTING CEILING . SALVAGE

CEILING TILES FOR REINSTALLATION. RETURN UNUSED CEILING TILES TO VA FOR STORAGE.

D2. REMOVE EXISTING GYPSUM BOARD CEILING AND FRAMING ABOVE.

D3. REMOVE EXISTING LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS FOR FULL SCOPE OF

WORK RELATED TO ELECTRICAL DEMOLITION AND REWORK.

C1. INSTALL NEW CEILING GRID AND EDGE ANGLE. INSTALL SALVAGED CEILING TILES TO

MATCH EXISTING ADJACENT CONDITIONS. INSTALL NEW CEILING TILES WHERE SALVAGED

TILES DO NOT MATCH.

C2. INFILL CEILING TO MATCH ADJACENT EXISTING CEILING TO REMAIN.

C3. REPOSITION EXISTING LIGHT FIXTURES CENTERED IN ROOM AND WITHIN CEILING GRID.

C4. EXPOSED CEILING.

A

OFFICE

A143

OFFICE

C101

OFFICE

A144

OFFICE

A143

OFFICE

C101

TR

A144

D1 B

D

OFFICE

A143

TR

A144

OFFICE

A143

OFFICE

A144

ARCHITECTURAL - BUILDING 1 - LEVEL 1

- ENLARGED PLANS

DA JM

A-B01-412

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

K:

\C

C G

_P R

O

JE

C

TS

\2

1\

-1

T op ek a

EH

R M

C

1R

\4

- D es

D oc s\

2- D ra w in gs

\W O

R

KI

N G

\A ut oC

AD

\A -B

-4

.d w g

/3

1/

:3 9:

A

M

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE

UPGRADES

COLMERY O'NEIL VA HEALTH CARE

21-116

Revisions: Date:

www. bancroft-ae.com

3300 Dundee RD.

Northbrook, IL 60062

T: 847.952.9362

35% SCHEMATIC DESIGN SUBMISSION 07-12-22

95% CONSTRUCTION DOCUMENTS SUBMISSION 10-31-23

100% FINAL BID DOCUMENT SUBMISSION

11/28/2023

12-19-23

Bancroft Project No: 21-116

VA REVIEW ONLY - NOT FOR CONSTRUCTION

35% SCHEMATIC DESIGN SUBMISSION R1 09-21-22

A213 A212

A221A A220

A214

A219

A217 A215

A2-03 A221E A212EA216A A218

A218A A218B A221 DNDN DN

DN UPDNUP

UP

UP UP

A

B

C

D

E

F

1 2 3 4 5 11 13 16 18 19 21 23 25 26 27 286 8 9

11.1

14 15 17

K

L

M

29 30

G

O

Q

S

T

U

V

P

S.2

S.1

Q.1

U.1

V.1

V.2

W.1

X

Y

8.26.36.2 10.19.3 12.111.2

2.1

3.1

4.1

3.8

Z.4

4.7 6.1 8.1 11.7

Z.3

Z.2

24 31 32

N

7 222010 12

18B 20B 22B 24B 24C

H

I

J

R

W

Z.1

A229C

A226

A222FA212A

A222

A211

A203E

A204

A202E

A202A A202A203

A223

A229B

A229E

A225

A226E

A227

B201

A230A A230F

A2

B202

B226E

B211M B230

A2-04

A2-01

A2-05

A2-02

B2-01

B2-02

B211

A228

B216E

B223A B223

B223B

B220B

B2

B218A

B217

B224A

B224

B219

B225

B221A B222

B226

B221B

B221

B231

B231C

B2

A

B231B

B230A

B213

B214

B231D

B2

G

A229

A229A

B212

B215

B210

B210A

B204 B204C

B205

B206 B206F

B208A

B208

B2

B

B208C B209AB209

B2

B

B2

B2

B B204A

B203

C208A

C208B

C208M

C208

C203E

C211E C201F

C204 C207C206

C210 C210A

C211

C203

C212

C213

C214

C202

C2-01 C209

C215

C201A

C201

C201B A232A231 A233

C2-02

A234

A235A

A236

A201

A201A

B216

B2-04

B2-03 B218B215F

A2-E1

A2-E2

A2-E3 A2-E4

A223

A206F

A207 A206D

A206E A206C

A208

A209A

A209

A210

A210A A2-04

A206 A206B

A206A

B226A

A223A

5,6,7&8 A-B01-421

3&4 M-B01-421

1&2

FP-B01-422

A-01-422

1,2,3&4 A-B01-421

1&2

FP-B01-421

1&2 M-B01-421

RATED PARTITION LEGEND

CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.

1 HR FIRE BARRIER

2 HR FIRE BARRIER

SMOKE BARRIER

1 HR FIRE BARRIER (EXISTING)

2 HR FIRE BARRIER (EXISTING)

SMOKE BARRIER (EXISTING)

1. REMOVE AND STORE CEILING TILES IN THIS AREA AS REQUIRED FOR MECHANICAL

DUCTWORK, PIPING, ELECTRICAL CONDUIT, TECHNOLOGY EQUIPMENT AND/OR

SECURITY INSTALLATION. REINSTALL TILES AND GRID WHEN WORK IS COMPLETED.

REPLACE ANY DAMAGED TILES AND GRIDS TO MATCH EXISTING. G.C. SHALL

TEMPORARILY ERECT A SUSPENDED PLASTIC BARRIER 6 MIL AROUND AREA OF

CEILING WORK TO BE PERFORMED DURING ONE SHIFT AND G.C. SHALL REMOVE

SUSPENDED PLASTIC BARRIER AT THE END OF SHIFT. G.C. SHALL MOP CLEAN THIS

AREA OF WORK. PRIOR TO TURNING OVER AREA TO VA. AFTER WORK HOURS WILL

REQUIRE ADDITIONAL COORDINATION WITH THE VA.

A. REFER TO TECHNOLOGY AND ELECTRICAL FOR FULL REQUIRED INSTALLATION

AND DEMOLITION WORK

B. ALL EXISTING LIGHTING, CONDUIT, DUCTWORK, MECHANICAL GRILLS, &

SPRINKLER HEADS TO REMAIN IN EXISTING LOCATIONS AND PROTECTED

UNLESS OTHERWISE NOTED.

C. ANY ELECTRICAL FIXTURES AND DEVICES THAT ARE NOT IDENTIFIED ON THESE

DRAWINGS IN THE AREAS OF CEILING DEMOLITION, ARE TO BE CAREFULLY

REMOVED FROM THE CEILING, PROTECTED, TEMPORARILY HUNG AND THEN

REATTACHED IN THE SAME LOCATIONS AS WHICH THEY WERE FOUND PRIOR TO

DEMOLITION.

D. CONTRACTOR TO CAREFULLY REMOVE SECTIONS OF EXISTING CEILING TILE TO

ALLOW FOR THE INSTALLATION OF ALL REQUIRED CONDUIT AND ELECTRICAL

EQUIPMENT PER CONTRACT DRAWINGS. CONTRACTOR SHALL REINSTALL

CEILING IN EXACT LOCATION. CONTRACTOR TO REPLACE ANY CEILING

GRID/TILES DAMAGED DURING CONSTRUCTION, MATCHING EXISTING. REFER TO

ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION.

E. IF A RATED ASSEMBLY IS NOT INSTALLED BY END OF SHIFT IT MUST BE

PROTECTED OVERNIGHT.

GENERAL DEMOLITION NOTES

CEILING DEMOLITION LEGEND

CEILING DEMOLITION KEY NOTESX

1. REPLACE EXISTING A,B&C TYPE FIRE EXTINGUISHER WITH CLEAN AGENT A,B&C

TYPE FIRE EXTINGUISHER.

2. INSTALL CLEAN AGENT A,B&C TYPE FIRE EXTINGUISHER IN SEMI-RECESSED

CABINET SET IN NEW GYP. BD. ON METAL STUD ASSEMBLY (1-HR RATED)

3. INSTALL CLEAN AGENT A,B&C TYPE FIRE EXTINGUISHER IN SEMI-RECESSED

CABINET IN EXISTING WALL WRAP CABINET IN TYPE 'X' GYPSUM BOARD.

FLOOR PLAN KEY NOTESX

KEYNOTE 11

A. ALL WORK ASSOCIATED WITH TEMPORARY CEILING REMOVAL AND INSTALLATION

OF CABLING SHALL BE CONSIDERED AS NO MORE HAZARDOUS THAN NORMAL

OPERATIONS. INFECTION CONTROL REQUIREMENTS FOR THIS WORK SHALL

INCLUDE "VISQUEEN" TYPE BARRIER AROUND WORK AND/OR INFECTION CONTROL

MODULES WITH VA STATION APPROVAL. CONTRACTOR SHALL ALSO ADHEAR TO

"INFECTION CONTROL REQUIREMENTS BY ALL CLASSES" ON SHEET GI101.

B. AT LOCATION OF ALL CORES THROUGH FLOORS INSTALL RE-ENTERABLE FIRESTOP

ASSEMBLIES.

C. AT LOCATION OF CORES THROUGH RATED PARTITIONS INSTALL RE-ENTERABLE

FIRESTOP ASSEMBLIES (TYP.)

D. CONTRACTOR TO LOCATE EXISTING REINFORCING PRIOR TO CORING FOR

CONDUIT. DO NOT CUT REINFORCEMENT. CORES SHALL HAVE 4" CLEAR MINIMUM

BETWEEN THEM. ADJUST CORE LOCATIONS AS NEEDED. AT LOCATIONS WITH

MORE THAN TWO (2) CORES PASSING THROUGH A C.M.U. WALL, SPACE CORES AT

16" MINIMUM.

GENERAL PLAN NOTES

CEILING LEGEND

ARCHITECTURAL - BUILDING 1 - LEVEL 2

PLAN

DA JM

A-B01-102

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

K:

\C

C G

_P R

O

JE

C

TS

\2

1\

-1

T op ek a

EH

R M

C

1R

\4

- D es

D oc s\

2- D ra w in gs

\W O

R

KI

N G

\A ut oC

AD

\A -B

-1

.d w g

/6

/2

9:

:1

AM

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE

UPGRADES

COLMERY O'NEIL VA HEALTH CARE

21-116

Revisions: Date:

www. bancroft-ae.com

3300 Dundee RD.

Northbrook, IL 60062

T: 847.952.9362

35% SCHEMATIC DESIGN SUBMISSION 07-12-22

95% CONSTRUCTION DOCUMENTS SUBMISSION 10-31-23

100% FINAL BID DOCUMENT SUBMISSION

11/28/2023

12-19-23

Bancroft Project No: 21-116

VA REVIEW ONLY - NOT FOR CONSTRUCTION

35% SCHEMATIC DESIGN SUBMISSION R1 09-21-22

35% SUBMITTAL II 06-13-23

65% DESIGN DEVELOPMENT SUBMITTAL 09-12-23

A223A A233

C212

A234

B226A

A235

C208A

MATERIAL DESCRIPTION MATERIAL LOCATION

9” x 9” Various Color Floor Tile

C7B, C125, C212, A233A, B325A, A554, A601, A601B, A618A

12” x 12” Brown Floor Tile and Mastic

A234, beneath raised floor

Yellow Sheet Vinyl Flooring

C302

Cement Board Radiator Cabinet Backing

A13, A127A, B119, C125, A232A, A233A, A234, A235, A328, B226A, B325A, C303, A432, B402, C402, A525, C503, A601, A601A, A604, A618

BUILDING 01: ACM & LBP SURVEY

SEE REPORT 8/16/2022 FOR DETAILS

*A233*

*ASSUME SIMILAR CONDITIONS AT THESE LOCATIONS

*A233*

Building 01 - LBP Survey

• Metal window frame in room A235 – tan paint

• Metal window sill in room A328 – brown paint

• Glazing on ceramic wall tile in rooms C208A, A601A, A604B

B. FOR GENERAL INFECTION CONTROL NOTES AND DETAILS REFER TO SHEET GI101.

C. FOR FINISH SCHEDULE REFER TO SHEET AF-601.

D. EXISTING IT/TR/OI&T ROOMS TO REMAIN ACTIVE DURING CONSTRUCTION. G.C. TO PROTECT EQUIPMENT DURING CONSTRUCTION WITH VISQUEEN. CONTRACTOR TO ENSURE CONTINUOUS

OPERATION OF EQUIPMENT.

E. NOT ALL KEY NOTES APPLY TO ALL PLAN SHEETS. G.C. TO APPLY ONLY AS INDICATED PER EACH SHEET.

F. MAINTAIN A 4 ' - 0" CLEAR PATH OF TRAVEL IN THE CORRIDORS AT ALL TIMES.

G. ALL WORK TO BE PERFORMED AS PART OF TR MODIFICATION SHALL BE CONSIDERED AS TYPE IV AND FOLLOW "INFECTION CONTROL PRECAUTIONS FOR CLASS IV" ON SHEET GI101.

H. APPLY FIRE RATED SEALANT TO ALL EXISTING AND NEW PENETRATIONS IN EXISTING WALLS TO MAKE EXISTING WALLS A 1 HR ASSEMBLY. BASIS OF DESIGN FOR 1 HR WALL IS UL 419 ASSEMBLY.

I. ALL EXISTING WALLS WITH TR'S ARE TO BE FULLY PATCHED & PREPPED TO A LIKE NEW APPEARANCE BEFORE RECEIVING NEW PLYWOOD PANELS.

J. IN ALL EXISTING OI&T AND IRM ROOMS TO BE CONVERTED TO TR'S - ALL EXISTING PLYWOOD PANELS TO BE REMOVED A WALLS PATCHED AND PREPPED TO RECEIVE PAINT AND NEW PLYWOOD

PANELS.

RATED PARTITION LEGEND

1. INSTALL TEMPORARY FLAME RESISTANT CONSTRUCTION PANELS WITH DOOR ENTRY. BASIS

OF DESIGN IS EDGE GUARD.

2. SUPPLY AND INSTALL WALK OFF MAT(S). SEE DETAILS ON SHEET GI101.

3. EXISTING HANDRAIL, WALL BASE AND CARPET TO BE MODIFIED TO ACCEPT NEW DOOR.

4. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY. INFILL WALL WITH

METAL STUDS AND DRYWALL. ALIGN WITH EXISTING WALLS, PATCH, LEVEL AND FINISH TO

MATCH EXISTING WALL FINISH.

5. REMOVE EXISTING DOOR, FRAME AND HARDWARE IN ITS ENTIRETY FOR INSTALLATION OF

NEW DOOR AND FRAME. PORTIONS OF EXISTING WALL TO BE DEMOLISHED TO RECEIVE NEW

LARGER SIZE DOOR AND FRAME ASSEMBLY. PATCH ADJACENT WALLS TO MATCH ADJACENT

CONDITIONS. RELOCATE ALL WALL MOUNTED ITEMS INCLUDING ROOM SIGNAGE, CHAIR

RAILS, CORNER GUARDS AND WALL MOUNTED ADJACENT TO EXISTING CORRIDOR DOOR AND

REINSTALL AT NEW DOOR LOCATION.

6. REMOVE EXISTING DOOR, FRAME AND HARDWARE. PREPARE WALL CONSTRUCTION AT

OPENING FOR NEW FRAME.

7. REMOVE GLASS FROM WINDOW SYSTEM AT THIS LOCATION. PREPARE WINDOW SYSTEM TO

RECEIVE INFILL AS NOTED IN NEW WORK SCOPE.

8. REMOVE EXISTING BASE AND/OR WALL CABINETS, COUNTERTOP, AND…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .