Attachment 14 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part5.pdf

PDF 19 MB Posted

Attached to
Z2DA--689A4-22-700 EHRM Infrastructure, Newington CONSTRUCTION SOLICITATION (VA-24-00028377)
Solicitation number
36C77624B0015_1
Issued by

About this file

This appears to be a construction drawing/specifications file, labeled as Part 5 of the Infrastructure Facility Component (IFC) documentation for the Electronic Health Record Modernization (EHRM) project at the VA Medical Center in Newington. However, without being able to view the actual contents of the PDF file, I cannot provide specific details about what this particular part contains in terms of technical specifications, drawings, or requirements. The file is related to solicitation number 36C77624B0015_1 for a construction project that will upgrade IT and communications infrastructure across multiple buildings (1C, 2E, 2C, 2W, 3, 12, 32, 33, 34, 42, 65) at the Newington VAMC to support the national Cerner electronic health record implementation.

View the file

Other files

File Type Posted
Technical Questions Tracking Spreadsheet - 2-13-25 - 36C77624B0015 - Construct EHRM Infrastructure Upgrades Newington CT.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0007.pdf PDF
Attachment 34 - 689A4-22-700.EHRM.Newington.Add3.20250211.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0006.pdf PDF
Attachment 27 - Wage Rates 01.31.25- Hartford.pdf PDF
Bid Opening Details - Newington CT - 36C76624B0015.pdf PDF
Site Visit Sign In Sheet 2.3.25.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0005.pdf PDF
Attachment 33 - Site Visit Instructions - Updated 1.27.25.pdf PDF
Attachment 2 - 689A4-22-700.EHRM.Newington.Spec.Final.20240806.Part1.pdf PDF
Attachment 21 - 689A4-22-700.Newington.EHRM.IFC.B32_33_34.20240703.part2.pdf PDF
Attachment 13 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part4.pdf PDF
Attachment 17 - 689A4-22-700.Newington.EHRM.IFC.B03_42.20240703.part2.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0004.pdf PDF
Attachment 22 - 689A4-22-700.Newington.EHRM.IFC.B65.20240703.part1.pdf PDF
Attachment 32 - 689A4-22-700.EHRM.Newington -.20250114 - Addendum 2.pdf PDF
Attachment 3 - 689A4-22-700.EHRM.Newington.Spec.Final.20240806.Part2.pdf PDF
Attachment 12 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part3.pdf PDF
Attachment 15 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part6.pdf PDF
Attachment 20 - 689A4-22-700.Newington.EHRM.IFC.B32_33_34.20240703.part1.pdf PDF
Attachment 33 - Site Visit Instructions - Updated 1.23.25.pdf PDF
Attachment 18 - 689A4-22-700.Newington.EHRM.IFC.B03_42.20240703.part3.pdf PDF
Attachment 23 - 689A4-22-700.Newington.EHRM.IFC.B65.20240703.part2.pdf PDF
Attachment 19 - 689A4-22-700.Newington.EHRM.IFC.B12.20240703.pdf PDF
Attachment 10 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part1.pdf PDF
Technical Questions Tracking Spreadsheet - 1-23-25 - 36C77624B0015 - Construct EHRM Infrastructure Upgrades Newington CT .pdf PDF
Attachment 16 - 689A4-22-700.Newington.EHRM.IFC.B03_42.20240703.part1.pdf PDF
Attachment 24 - 689A4-22-700.Newington.EHRM.IFC.SITE.20240703.pdf PDF
Attachment 11 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part2.pdf PDF
Attachment 31 - EHRM Newington-Pre Bid Presentation.010725.R02.pdf PDF
Technical Questions Tracking Spreadsheet - 1-6-25 - 36C77624B0015 - Construct EHRM Infrastructure Upgrades Newington CT.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0003.pdf PDF
2025-01-07 Preproposal conference sign in list.pdf PDF
Attachment 30 - Price Schedule - 36C77624B0015 - 689A4-22-700 EHRM Infrastructure Newington.pdf PDF
Attachment 28 - Site Visit Instructions - Updated 1.6.25.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0002.pdf PDF
Attachment 19 - Newington EHRM Drawings - Part 10 of 16 - 12.31.24.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0001.pdf PDF
Attachment 29 - 689A4-22-700.EHRM.Newington.Add1.20241213.pdf PDF
Attachment 28 - Site Visit Instructions.pdf PDF
Attachment 24 - Newington EHRM Drawings - Part 15 of 16.pdf PDF
Attachment 11 - Newington EHRM Drawings - Part 2 of 16.pdf PDF
Attachment 26 - Newington VAHC campus map.pdf PDF
Attachment 22 - Newington EHRM Drawings - Part 13 of 16.pdf PDF
Attachment 23 - Newington EHRM Drawings - Part 14 of 16.pdf PDF
Attachment 3 - 689A4-22-700.EHRM.Newington.Spec.Final.20240806.Part2.pdf PDF
Attachment 14 - Newington EHRM Drawings - Part 5 of 16.pdf PDF
Attachment 10 - Newington EHRM Drawings - Part 1 of 16.pdf PDF
Attachment 27 - Wage Rates 8.9.24- Hartford.pdf PDF
Attachment 9 - Underground Utility Locating.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WAPWAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

F2

T-

1C

OPEN

OFFICE

2W-102

TOILET

2W-104

TOILET

2W-106

CORRIDOR

2W-1C3

EXAM

2W-105A

EXAM

2W-101

NURSE

MANAGER

2W-100

CHASE

CORRIDOR

1C1-02W

CORRIDOR

2W-1C2

CLEAN

STORAGE

2W-103A

EXAM

2W-103B

EXAM

2W-108A

EXAM

2W-109A

EXAM

2W-112

EXAM

2W-114

MALE

TOILET

2W-115

FEMALE

PATIENT

TOILET

2W-116

TELECOM

ROOM

2W-121

EXAM

2W-123

STAIR #9

2W-S9

CHASE

ELEC

2W-129

TOILET

2W-113

CHASE

TOILET

2W-110

EQUIP

2W-109B

EXAM

2W-108B

EXAM

2W-130A

EXAM

2W-127

TOILET

2W-126

CORRIDOR

2W-1C5

FMS

COMM

2W-128

OPEN

OFFICE

2W-117

CORRIDOR

2W-1C4

MED

2W-131C

PHARM D

2W-132B

OIT COMM

2W-132A

CONFERENCE

ROOM

2W-107A

VESTIBULE

2W-215

CHASE

EXAM

2W-105B

EXAM

2W-107B

EXAM

2W-130B

CLEAN

UTIL

2W-131B

HAC

2W-131A

EXAM

2W-118

EXAM

2W-120

EXAM

2W-119

SOILED

UTILITY

2W-122

ANTE

2W-124

WOMEN

ISO/ PROC

2W-125

2W -1

-B

2W -1

-C

2W -1

-D

2W-117-E

2W-117-F

2W-117-G

2W-117-H

2W-117-J

2W-117-K

2W-118-A

2W-118-B

2W-119-A

2W-119-B

2W-120-A

2W-120-B 2W-122-A

2W-125-D

2W-125-C

2W-125-A

2W -1

-B

2W-127-A

2W-127-B

2W-130A-A

2W-130A-B

2W-130B-A

2W-130B-B

2W-132B-A

2W-132B-B

2W-132B-C

2W-132B-D

2W-121-A

2W-121-B 2W-123-B

2W-123-A

2W-131C-C 2W-131C-B

2W-131C-A

2W-114-C

2W-114-B

2W-114-A

2W-112-C

2W-112-B

2W-112-A

2W-109A-C

2W-109A-B

2W-109A-A

2W-108A-C

2W-108A-B

2W-108A-A

2W-107A-B

2W-107A-A

2W-108B-A

2W-108B-B

2W-103B-A

2W-103B-B

2W-103A-A

2W-100-A

2W-100-B

2W-101-A

2W-101-B

2W-102-A 2W-102-W2W-102-V

2W-102-B

2W-102-C

2W-102-D

2W-102-E2W-102-M2W-102-T

2W-102-U

2W-105A-A

2W-105A-B

2W-105B-B

2W-105B-A

2W-107A-B

2W-107A-A

2W-107A-C

2W-102-Q

2W-102-R

2W-102-S

2W-102-P

2W-102-O

2W-102-N

2W-102-J

2W-102-K

2W-102-L

2W-102-H

2W-102-G

2W-102-F

2W-117-A

2W-CAM-01

2W-CAM-02

2W -1

C 5-

A

2W -1

C 5-

C 2W

-1 C

5- B

2W-215-A 2W-215-CAM-01

TYP.

2W-102-AP-A2W-107A-AP-A

2W -1

C 3-

AP

-A

2W-112-AP-A

2W-117-AP-A 2W-125-AP-A

2W-1C4-AP-A

2W-108B-AP-A

2W-130B-AP-A

2W-215-AP-A

02T-101W F4

TYP.

F2

T-

1C

2W-121-CAM-01

TELECOM

ROOM

2W-121

115 SF

CORRIDOR

2W-1C4

CORRIDOR

2W-1C3

EXAM

2W-123

STAIR #9

2W-S9

TYP.

2W-121-CAM-01

2W-121-A

2W-121-BTYP.

3'

- 0

3' - 0"

3' - 3"

7'

- 1

TYP.

FIBER PATH A

FIBER PATH B

FIBER PATH LEGEND

SERVICE PROVIDER A

SERVICE PROVIDER B

07/03/2024

07/03/2024

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

2W

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

2C 2E

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:2

02T-101W

TELECOMMUNICATION PLAN - FIRST LEVEL -

B2W

689A4-22-700

01_02

07/03/2024 M. Perkins K.

MCDERMOTT

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

SCALE: 1/8" = 1'-0"F6

TELECOMMUNICATION PLAN - FIRST

LEVEL - B2W

SCALE: 3/8" = 1'-0"F4

TELECOMMUNICATION ENLARGED

PLAN - FIRST LEVEL - RM 2W-121

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

ALL NEW CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL

THIN WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE

NOTED. UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL.

IF EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A

CABLE TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR

SHALL PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO

REPLACE EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

REFER TO R-900 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

O. FOR EXISTING SECURITY CAMERAS BEING RE-CABLED, MAINTAIN EXISTING

CAMERA ANGLE AND PROTECT IN PLACE.

P. ALL EXISTING PENETRATIONS NO LONGER BEING USED WILL BE FILLED WITH

RATED ASSEMBLY.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS.

PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE CAREFULLY

PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING RACK SHALL BE

TRANSFERRED TO THE NEW RACK. CONTRACTOR SHALL PROVIDE SHOP

DRAWINGS SHOWING THE PROPOSED NEW RACK ELEVATION AND PROVIDE A

PHASING PLAN FOR TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE

NEW RACKS.

PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK. SEE

T-500 SERIES SHEETS FOR ADDITIONAL REQUIREMENTS. COORDINATE LIGHT

FIXTURES WITH OVERHEAD CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%.

PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. MOUNT AT 8 ’ – 6” A.F.F. TO

TOP OF WALL BRACKET. INTEGRATE CAMERA INTO EXISTING VMS.

PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

NEW 4” SPEED CONDUIT SLEEVE THROUGH WALL ABOVE CEILING GRID FOR

HORIZONTAL VOICE/DATA CABLING OR FIBER WITH PLASTIC BUSHINGS ON BOTH

ENDS TO PROTECT CABLES,CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%. FIRE CAULK PENETRATION PER SPECIFICATIONS.

EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

DEMOLISH EXISTING FIBER ONCE NEW FIBER IS OPERATIONAL. CONTRACTOR

SHALL PROVIDE A PHASING PLAN FOR TRANSFERRING FIBER.

ALL EXISTING ANALOG PHONE CABLE DEVICES AND TERMINATIONS ETC. SHALL

REMAIN OPERATIONAL AT ALL TIMES AND SHALL BE RETAINED AND REUSED.

PROTECT IN PLACE.

VERTICAL ROUTE FOR TELECOM RISER. SEAL ALL FLOOR PENETRATIONS TO

MAINTAIN FIRE RATING.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

EXISTING PACS AND EQUIPMENT RACKS TO REMAIN, PROTECT IN PLACE.

NEW INDOOR UNITS.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

NOTE: NOT ALL KEYNOTES

ARE USED ON EACH SHEET

Revisions: Date:

TELEPHONE

RM

1C-143

150 SF

TELECOM

ROOM

1C-142

156 SF

CORRIDOR

1C-C1-6

TELEPHONE

RM

1S-164 -

1C-141

MECH

1S-176

121 SF

CONTROL

RM

174F

CORRIDOR

1S-C1-5

CORRIDOR

1S-C1-4

1S-176-C

1S-176-B

1S-176-A

TYP.

5 7 11 18

I555

NWNTCTVAH01

FIBRE

DEMARCATION

POINT

TELEPHONE

RM

1S-164

530 SF

CORRIDOR

1S-C1-5

TELEPHONE

RM

1C-143

MECH RM

1S-167

5 7 11 18

TELEPHONE

RM

1C-143

150 SF

TELECOM

ROOM

1C-142

156 SF

CORRIDOR

1C-C1-6

1C-141

1C-C1-6-CAM-1

3 4

MAIN INCOMING

WAN FIBER FROM

SERVICE PROVIDER A

TERMINATE IN 1C-142

3'

- 0

FIBRE PATH A

(1) 24F OS2 CABLE

BLDG 2E (1) OS2 CABLE

FIBRE PATH A

(1) 24F OS2 CABLE

BLDG 2E (1) OS2 CABLE

TYP.

4' - 10 1/2" 3' - 0"

6'

- 1

1/

2"

1C-142-A

1C-142-B

1C-142-C

1C-142-D 1

WALL SYMBOL LEGEND

EXISTING CONSTRUCTION TO REMAIN

SMOKE AND 1-HR RATED FIRE

BARRIER AND OPENINGS

SMOKE AND 2-HR RATED FIRE BARRIER

AND OPENINGS

SMOKE BARRIER AND OPENINGS

1 HR RATED FIRE BARRIER AND

OPENINGS

2 HR RATED FIRE BARRIER AND OPENINGS

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

FIBER PATH A

FIBER PATH B

FIBER PATH LEGEND

SERVICE PROVIDER A

SERVICE PROVIDER B

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:2

01T-401

TELECOMMUNICATION ENLARGED PLANS- B1 689A4-22-700

01_02

07/03/2024 M. Perkins N. Wicklund

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

SCALE: 1/2" = 1'-0"F6

TELECOMMUNICATION ENLARGED

PLAN - FIRST LEVEL - RM 1C-142 / RM

1C-143 - DEMO

SCALE: 1/2" = 1'-0"F1

TELECOMMUNICATION ENLARGED

PLAN - FIRST LEVEL - RM 1S-176 -

EXISTING

SCALE: 1/2" = 1'-0"C1

TELECOMMUNICATION ENLARGED

PLAN - FIRST LEVEL - RM 1S-164 -

EXISTING

SCALE: 1/2" = 1'-0"F3

TELECOMMUNICATION ENLARGED

PLAN - FIRST LEVEL - RM 1C-142 / RM

1C-143 - NEW

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

ALL NEW CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL

THIN WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE

NOTED. UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL.

IF EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A

CABLE TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR

SHALL PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO

REPLACE EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

REFER TO R-900 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

O. FOR EXISTING SECURITY CAMERAS BEING RE-CABLED, MAINTAIN EXISTING

CAMERA ANGLE AND PROTECT IN PLACE.

P. ALL EXISTING PENETRATIONS NO LONGER BEING USED WILL BE FILLED WITH

RATED ASSEMBLY.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS.

PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE CAREFULLY

PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING RACK SHALL BE

TRANSFERRED TO THE NEW RACK. CONTRACTOR SHALL PROVIDE SHOP

DRAWINGS SHOWING THE PROPOSED NEW RACK ELEVATION AND PROVIDE A

PHASING PLAN FOR TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE

NEW RACKS.

PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK. SEE

T-500 SERIES SHEETS FOR ADDITIONAL REQUIREMENTS. COORDINATE LIGHT

FIXTURES WITH OVERHEAD CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%.

PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. MOUNT AT 8 ’ – 6” A.F.F. TO

TOP OF WALL BRACKET. INTEGRATE CAMERA INTO EXISTING VMS.

PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

NEW 4” SPEED CONDUIT SLEEVE THROUGH WALL ABOVE CEILING GRID FOR

HORIZONTAL VOICE/DATA CABLING OR FIBER WITH PLASTIC BUSHINGS ON BOTH

ENDS TO PROTECT CABLES,CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%. FIRE CAULK PENETRATION PER SPECIFICATIONS.

EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

DEMOLISH EXISTING FIBER ONCE NEW FIBER IS OPERATIONAL. CONTRACTOR

SHALL PROVIDE A PHASING PLAN FOR TRANSFERRING FIBER.

ALL EXISTING ANALOG PHONE CABLE DEVICES AND TERMINATIONS ETC. SHALL

REMAIN OPERATIONAL AT ALL TIMES AND SHALL BE RETAINED AND REUSED.

PROTECT IN PLACE.

VERTICAL ROUTE FOR TELECOM RISER. SEAL ALL FLOOR PENETRATIONS TO

MAINTAIN FIRE RATING.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

EXISTING PACS AND EQUIPMENT RACKS TO REMAIN, PROTECT IN PLACE.

NEW INDOOR UNITS.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

NOTE: NOT ALL KEYNOTES

DC

COMPUTER

RM

1C-148D

1372 SF

TOILET

1C-148G

RK

G5

RK

H5

RK

I5

RK

J5

RK

F5

ST

O

R

AG

E R

AC

K-

ST

O R

AG

E

R

AC

K-

STORAGE RACK-3STORAGE RACK -4

TE

LE

PH

O

N E

PA

TC

H

PA

N

EL

TE

LE

PH

O

N E

PA

TC

H

PA

N

EL

TELECOM

ROOM

1C-242

163 SF

OPTOMETRY

EXAM

1S-262

LOBBY

1C-241

LOBBY

1C-241

TELECOM

ROOM

1C-242

163 SF

OPTOMETRY

EXAM

1S-262

LOBBY

1C-241

LOBBY

1C-241

1C-242-CAM-1

3 4

TYP.

9 TYP.

3'

- 0

3' - 0"

5' - 2"

7'

- 8

/2

1C-242-C

1C-242-D

1C-242-A

1C-242-B

COMPUTER

RM

1C-148D

1372 SF

TOILET

1C-148G

CORRIDOR

1C-C1-8

307 SF

C R

AC

-1

C R

AC

-2

1C-C1-8-AP-A

1C-148F-B

1C-148E-C

1C-148F-A

1C-148D-CAM-03

1C-148D-CAM-02

1C-148D-CAM-01

1C-147-A

1C-148E-A1C-148E-B19

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

1C-148A-C1C-148A-B1C-148A-D

1C-148A-E

1C-148B-A

1C-148B-B

UPS A

UPS B

HDA A

MAIN DISTRIBUTION AREA - A SIDE

MAIN DISTRIBUTION AREA - B SIDE

1C-148A-A

BLDG 3

ENTRANCE

BLDG 3

COMPUTER

RM

1C-148D

MAIN INCOMING

WAN FIBER FROM

SERVICE PROVIDER B

TERMINATE IN MCR

24F OM4/12F OS1

FIBER PATH B

24F OM4/12F OS1

FIBER PATH A

FIBER PATH B

(6) 24F OM4/12F OS1 CABLE

BLDG 42 (6) 24F OM4/12F OS1

FIBER PATH A

(11) 24F OM4/12F OS1 CABLE

BLDG 2C (4) 24F OM4/12F OS1 CABLE

BLDG 2W (1) 24F OM4/12F OS1 CABLE

BLDG 3 (5) 24F OM4/12F OS1 CABLE

BLDG 32 (1) 24F 0M4/12F OS1 CABLE

FIBER PATH B

(2) 24F OS2 CABLE

BLDG 2W (1) OS2 CABLE

BLDG 42 (1) OS2 CABLE

FIBRE PATH A

(1) 24F OS2 CABLE

BLDG 2E (1) OS2 CABLE

FIBRE PATH B

(1) 24F OS2 CABLE

BLDG 2E (1) OS2 CABLE

FIBER PATH A

(2) 24F OS2 CABLE

BLDG 3 (2) 24F OS2 CABLE MDA B

HDA B

MDA A

IRM

OFFICE

1C-148B

127 SF

OFFICE

TECHNICIAN

1C-148A

186 SF

VESTIBULE

1C-148

55 SF

ELEC

PANEL

22 SF

OFFICE

SECY

1C-148F

125 SF

OFFICE

CHIEF

1C-148E

143 SF

CORRIDOR

307 SF

WALL SYMBOL LEGEND

EXISTING CONSTRUCTION TO REMAIN

SMOKE AND 1-HR RATED FIRE

BARRIER AND OPENINGS

SMOKE AND 2-HR RATED FIRE BARRIER

AND OPENINGS

SMOKE BARRIER AND OPENINGS

1 HR RATED FIRE BARRIER AND

OPENINGS

2 HR RATED FIRE BARRIER AND OPENINGS

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

FIBER PATH A

FIBER PATH B

FIBER PATH LEGEND

SERVICE PROVIDER A

SERVICE PROVIDER B

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:2

01T-402

TELECOMMUNICATION ENLARGED PLANS- B1 689A4-22-700

01_02

07/03/2024 M. Perkins N. Wicklund

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

SCALE: 1/4" = 1'-0"F5

TELECOMMUNICATION PLAN - FIRST

LEVEL - 1C-148D - DEMO

SCALE: 1/2" = 1'-0"F2

TELECOMMUNICATION PLAN -

SECOND LEVEL - ROOM NO 1C-242 -

DEMO

SCALE: 1/2" = 1'-0"C2

TELECOMMUNICATION PLAN -

SECOND LEVEL - ROOM NO 1C-242 -

NEW

SCALE: 1/4" = 1'-0"C5

TELECOMMUNICATION PLAN - FIRST

LEVEL - 1C-148D - NEW

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

ALL NEW CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL

THIN WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE

NOTED. UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL.

IF EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A

CABLE TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR

SHALL PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO

REPLACE EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

REFER TO R-900 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

O. FOR EXISTING SECURITY CAMERAS BEING RE-CABLED, MAINTAIN EXISTING

CAMERA ANGLE AND PROTECT IN PLACE.

P. ALL EXISTING PENETRATIONS NO LONGER BEING USED WILL BE FILLED WITH

RATED ASSEMBLY.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS.

PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE CAREFULLY

PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING RACK SHALL BE

TRANSFERRED TO THE NEW RACK. CONTRACTOR SHALL PROVIDE SHOP

DRAWINGS SHOWING THE PROPOSED NEW RACK ELEVATION AND PROVIDE A

PHASING PLAN FOR TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE

NEW RACKS.

PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK. SEE

T-500 SERIES SHEETS FOR ADDITIONAL REQUIREMENTS. COORDINATE LIGHT

FIXTURES WITH OVERHEAD CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%.

PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. MOUNT AT 8 ’ – 6” A.F.F. TO

TOP OF WALL BRACKET. INTEGRATE CAMERA INTO EXISTING VMS.

PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

NEW 4” SPEED CONDUIT SLEEVE THROUGH WALL ABOVE CEILING GRID FOR

HORIZONTAL VOICE/DATA CABLING OR FIBER WITH PLASTIC BUSHINGS ON BOTH

ENDS TO PROTECT CABLES,CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%. FIRE CAULK PENETRATION PER SPECIFICATIONS.

EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

DEMOLISH EXISTING FIBER ONCE NEW FIBER IS OPERATIONAL. CONTRACTOR

SHALL PROVIDE A PHASING PLAN FOR TRANSFERRING FIBER.

ALL EXISTING ANALOG PHONE CABLE DEVICES AND TERMINATIONS ETC. SHALL

REMAIN OPERATIONAL AT ALL TIMES AND SHALL BE RETAINED AND REUSED.

PROTECT IN PLACE.

VERTICAL ROUTE FOR TELECOM RISER. SEAL ALL FLOOR PENETRATIONS TO

MAINTAIN FIRE RATING.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

EXISTING PACS AND EQUIPMENT RACKS TO REMAIN, PROTECT IN PLACE.

NEW INDOOR UNITS.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

NOTE: NOT ALL KEYNOTES

ROOM

1-426

ROOM

1-420

CORRIDOR

1C-C4-5

1-424-A

1C-C4-5-CAM-1

TYP.

3'

- 0

TELECOM

ROOM

1-424

114 SF

3' - 0"

1-424-D

1-424-B

1-424-C

1' - 9 1/2"

6'

- 9

/2

TELECOM

ROOM

1-524

132 SF

1-524-A

1-524-B

EDUCATION

1-523

OFFICE

1-526

CORRIDOR

1N-C5-1

TYP.

1N-C5-1-CAM-1

7 6

3' - 0"

3'

- 0

3'

- 5

/2

6' - 9"

1-524-B

1-524-C

ROOM

1-426

ROOM

1-420

CORRIDOR

1C-C4-5

1-

4- A

M O

VE

D

T O

A D

JA

C

EN

T

W

AL

L

TELECOM

ROOM

1-524

132 SF

MOVED TO ADJACENT WALL

1-524-A

EDUCATION

1-523

CORRIDOR

1N-C5-1

OFFICE

1-526

COMMUNICATION

1-325

TELECOM

ROOM

1-324

156 SF

CORRIDOR

1S-C3-7

CORRIDOR

1N-C3-2

MENTAL

HEALTH

OFFICE

1-326

TELECOM

ROOM

1-324

156 SF

CORRIDOR

1S-C3-7

MENTAL

HEALTH

OFFICE

1-321

CORRIDOR

1N-C3-21N-C3-2-CAM-1

7'

- 8

3' - 0"

3'

- 0

3' - 0"

TYP.

1-324-A

1-324-C

1-324-D

1-324-B

4 3

PASSAGE

1N-220

38 SF

TELEPHONE

RM

1N-220A

17 SF

X-RAY RM

CHEST RM

1N-209

EXAM RM

1N-222

CORRIDOR

1N-C2-4

WALL SYMBOL LEGEND

EXISTING CONSTRUCTION TO REMAIN

SMOKE AND 1-HR RATED FIRE

BARRIER AND OPENINGS

SMOKE AND 2-HR RATED FIRE BARRIER

AND OPENINGS

SMOKE BARRIER AND OPENINGS

1 HR RATED FIRE BARRIER AND

OPENINGS

2 HR RATED FIRE BARRIER AND OPENINGS

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

FIBER PATH A

FIBER PATH B

FIBER PATH LEGEND

SERVICE PROVIDER A

SERVICE PROVIDER B

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:3

01T-403

TELECOMMUNICATION ENLARGED PLANS - B1 689A4-22-700

01_02

07/03/2024 M. Perkins N. Wicklund

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

SCALE: 1/2" = 1'-0"C3

TELECOMMUNICATION PLAN -

FOURTH LEVEL - 1-424 - NEW

SCALE: 1/2" = 1'-0"C1

TELECOMMUNICATION PLAN - FIFTH

LEVEL - 1-524 - NEW

SCALE: 1/2" = 1'-0"F3

TELECOMMUNICATION PLAN -

FOURTH LEVEL - 1-424 - DEMO

SCALE: 1/2" = 1'-0"F1

TELECOMMUNICATION PLAN - FIFTH

LEVEL - 1-524 - DEMO

SCALE: 1/2" = 1'-0"F5

TELECOMMUNICATION PLAN - THIRD

LEVEL - 1-324 - EXISTING

SCALE: 1/2" = 1'-0"C6

TELECOMMUNICATION PLAN - THIRD

LEVEL - 1-325 - NEW

SCALE: 1/2" = 1'-0"F8

TELECOMMUNICATION PLAN -

SECOND LEVEL - ROOM NO 1N-220 /

1N-220A - EXISTING

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

ALL NEW CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL

THIN WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE

NOTED. UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL.

IF EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A

CABLE TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR

SHALL PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO

REPLACE EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

REFER TO R-900 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

O. FOR EXISTING SECURITY CAMERAS BEING RE-CABLED, MAINTAIN EXISTING

CAMERA ANGLE AND PROTECT IN PLACE.

P. ALL EXISTING PENETRATIONS NO LONGER BEING USED WILL BE FILLED WITH

RATED ASSEMBLY.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS.

PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE CAREFULLY

PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING RACK SHALL BE

TRANSFERRED TO THE NEW RACK. CONTRACTOR SHALL PROVIDE SHOP

DRAWINGS SHOWING THE PROPOSED NEW RACK ELEVATION AND PROVIDE A

PHASING PLAN FOR TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE

NEW RACKS.

PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK. SEE

T-500 SERIES SHEETS FOR ADDITIONAL REQUIREMENTS. COORDINATE LIGHT

FIXTURES WITH OVERHEAD CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%.

PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. MOUNT AT 8 ’ – 6” A.F.F. TO

TOP OF WALL BRACKET. INTEGRATE CAMERA INTO EXISTING VMS.

PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

NEW 4” SPEED CONDUIT SLEEVE THROUGH WALL ABOVE CEILING GRID FOR

HORIZONTAL VOICE/DATA CABLING OR FIBER WITH PLASTIC BUSHINGS ON BOTH

ENDS TO PROTECT CABLES,CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%. FIRE CAULK PENETRATION PER SPECIFICATIONS.

EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

DEMOLISH EXISTING FIBER ONCE NEW FIBER IS OPERATIONAL. CONTRACTOR

SHALL PROVIDE A PHASING PLAN FOR TRANSFERRING FIBER.

ALL EXISTING ANALOG PHONE CABLE DEVICES AND TERMINATIONS ETC. SHALL

REMAIN OPERATIONAL AT ALL TIMES AND SHALL BE RETAINED AND REUSED.

PROTECT IN PLACE.

VERTICAL ROUTE FOR TELECOM RISER. SEAL ALL FLOOR PENETRATIONS TO

MAINTAIN FIRE RATING.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

EXISTING PACS AND EQUIPMENT RACKS TO REMAIN, PROTECT IN PLACE.

NEW INDOOR UNITS.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

NOTE: NOT ALL KEYNOTES

TYP.

TELECOM

ROOM

2C-1155

131 SF

ANTI

COAGULATION

CLINIC

EXAM RM

2C-1154

OPEN

OFFICE

2C-1165

CORRIDOR

2C-C1-14

IT

2C-1156

2C-1155-A

2C -1

5-

C

AM

-0

2C-1155-B

TYP.

FIBRE PATH B

(1) 24F OS2 CABLE

BLDG 2E (1) OS2 CABLE

FIBRE PATH A

(2) 24F OS2 CABLE

BLDG 2C (1) OS2 CABLE

BLDG 2W (1) OS2 CABLE

2'

- 0

/2

3' - 0"

3'

- 0

8' - 0 1/2"

TYP.

TELECOM

ROOM

2C-2139

198 SF

SECY OR

WAITING

2C-2138

DRUG

INFO OR

OFFICE

2C-2138C

2C-2138D-CAM-01

TELECOM

ROOM

2C-2139

3'

- 0

3' - 0"

4'

- 4

/2

8' - 2 1/2"

STORAGE

2C-3140

COMMUNICATION

2C-3143

TELECOM

ROOM

2C-3140A

181 SF

2C-3140A-AP-A

2C -3

0A

-C

AM

-0

2C-3140A-A

TYP.

3' - 0"

TYP.

3'

- 0

9' - 6"

5'

- 5

/2

TELECOM

ROOM

2C-1155

131 SF

ANTI

COAGULATION

CLINIC

EXAM RM

2C-1154

OPEN

OFFICE

2C-1165

CORRIDOR

2C-C1-14

IT

2C-1156

TELECOM

ROOM

2C-2139

198 SF

SECY OR

WAITING

2C-2138

SECY OR

WAITING

2C-2138

DRUG

INFO OR

OFFICE

2C-2138C

WALL SYMBOL LEGEND

EXISTING CONSTRUCTION TO REMAIN

SMOKE AND 1-HR RATED FIRE

BARRIER AND OPENINGS

SMOKE AND 2-HR RATED FIRE BARRIER

AND OPENINGS

SMOKE BARRIER AND OPENINGS

1 HR RATED FIRE BARRIER AND

OPENINGS

2 HR RATED FIRE BARRIER AND OPENINGS

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

FIBER PATH A

FIBER PATH B

FIBER PATH LEGEND

SERVICE PROVIDER A

SERVICE PROVIDER B

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:3

02T-401

TELECOMMUNICATION ENLARGED PLANS- B2C 689A4-22-700

01_02

07/03/2024 M. Perkins N. Wicklund

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

SCALE: 1/2" = 1'-0"F7

TELECOMMUNICATION ENLARGED

PLAN - FIRST LEVEL- RM 2C-1155 -

NEW

SCALE: 1/2" = 1'-0"F4

TELECOMMUNICATION ENLARGED

PLAN - SECOND LEVEL- RM 2C-2139 -

NEW

SCALE: 1/2" = 1'-0"F1

TELECOMMUNICATION ENLARGED

PLAN - THIRD LEVEL- RM 2C-3140A -

NEW

SCALE: 1/2" = 1'-0"C7

TELECOMMUNICATION ENLARGED

PLAN - FIRST LEVEL- RM 2C-1155 -

DEMO

SCALE: 1/2" = 1'-0"C4

TELECOMMUNICATION ENLARGED

PLAN - SECOND LEVEL- RM 2C-2138D

- DEMO

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

ALL NEW CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL

THIN WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE

NOTED. UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL.

IF EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A

CABLE TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR

SHALL PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO

REPLACE EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

REFER TO R-900 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

O. FOR EXISTING SECURITY CAMERAS BEING RE-CABLED, MAINTAIN EXISTING

CAMERA ANGLE AND PROTECT IN PLACE.

P. ALL EXISTING PENETRATIONS NO LONGER BEING USED WILL BE FILLED WITH

RATED ASSEMBLY.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS.

PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE CAREFULLY

PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING RACK SHALL BE

TRANSFERRED TO THE NEW RACK. CONTRACTOR SHALL PROVIDE SHOP

DRAWINGS SHOWING THE PROPOSED NEW RACK ELEVATION AND PROVIDE A

PHASING PLAN FOR TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE

NEW RACKS.

PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK. SEE

T-500 SERIES SHEETS FOR ADDITIONAL REQUIREMENTS. COORDINATE LIGHT

FIXTURES WITH OVERHEAD CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%.

PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. MOUNT AT 8 ’ – 6” A.F.F. TO

TOP OF WALL BRACKET. INTEGRATE CAMERA INTO EXISTING VMS.

PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

NEW 4” SPEED CONDUIT SLEEVE THROUGH WALL ABOVE CEILING GRID FOR

HORIZONTAL VOICE/DATA CABLING OR FIBER WITH PLASTIC BUSHINGS ON BOTH

ENDS TO PROTECT CABLES,CABLE TRAY AND SPEED SLEEVE FILL SHALL NOT

EXCEED 40%. FIRE CAULK PENETRATION PER SPECIFICATIONS.

EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

DEMOLISH EXISTING FIBER ONCE NEW FIBER IS OPERATIONAL. CONTRACTOR

SHALL PROVIDE A PHASING PLAN FOR TRANSFERRING FIBER.

ALL EXISTING ANALOG PHONE CABLE DEVICES AND TERMINATIONS ETC. SHALL

REMAIN OPERATIONAL AT ALL TIMES AND SHALL BE RETAINED AND REUSED.

PROTECT IN PLACE.

VERTICAL ROUTE FOR TELECOM RISER. SEAL ALL FLOOR PENETRATIONS TO

MAINTAIN FIRE RATING.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

EXISTING PACS AND EQUIPMENT RACKS TO REMAIN, PROTECT IN PLACE.

NEW INDOOR UNITS.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

NOTE: NOT ALL KEYNOTES

COMMUNICATION

2C-1121

52 SF

CASHIER

2C-1120

COMMUNICATION

CTR

2C-1119

STORAGE

2C-1119A

ELECTRICAL

2C-1122

CORRIDOR

2C-1032

5 11 14 17

IT

2C-1156

36 SF

CORRIDOR

2C-C1-14

STAIR #4

TELECOM

ROOM

2C-1155

5 11 14 17

STAIR#4

CORRIDOR

2C-C2-3

SECY OR

WAITING

2C-2138

TELECOM

ROOM

2C-2139

5 11 14 17 TELECOM

ROOM

2C-2139

198 SF

COMMUNICATION

2C-3143

85 SF

STAIR#4

CONFERENCE

RM

2C-3139

STAIR#4

5 11 14 17

WALL SYMBOL LEGEND

EXISTING CONSTRUCTION TO REMAIN

SMOKE AND 1-HR RATED FIRE

BARRIER AND OPENINGS

SMOKE AND 2-HR RATED FIRE BARRIER

AND OPENINGS

SMOKE BARRIER AND OPENINGS

1 HR RATED FIRE BARRIER AND

OPENINGS

2 HR RATED FIRE BARRIER AND OPENINGS

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

FIBER PATH A

FIBER PATH B

FIBER PATH LEGEND

SERVICE PROVIDER A

SERVICE PROVIDER B

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:3

02T-402

TELECOMMUNICATION ENLARGED PLANS- B2C 689A4-22-700

01_02

07/03/2024 M. Perkins N. Wicklund

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTED SOLUTION FOR THE CABLING.

ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN

WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.

UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF

EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE

TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL

PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE

EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

REFER TO R-900 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

O. FOR EXISTING SECURITY CAMERAS BEING RE-CABLED, MAINTAIN EXISTING

CAMERA ANGLE AND PROTECT IN PLACE.

P. ALL EXISTING PENETRATIONS NO LONGER BEING USED WILL BE FILLED WITH

RATED ASSEMBLY.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS. PHASE TO PROVIDE NEW RACK IN A TEMPORARY LOCATION

AND TRANSFER DATA CIRCUITS FROM THE EXISTING RACK TO THE NEW RACK.

PROVIDE TEMPORARY EXTRA LENGTH JUMPER CABLES TO EXISTING SWITCHES

AND OTHER DEVICES TO ENSURE UNINTERRUPTED SERVICE. ONCE ALL EXISTING

DATA CIRCUITS ARE RELOCATED TO NEW PATCH PANELS ON THE NEW RACK AND

ALL EXISTING DEVICES TO REMAIN ARE TRANSFERRED TO THE NEW RACK,

REMOVE THE EXISTING RACK AND INSTALL THE NEW RACKS IN THE FINAL

PERMANENT POSITION.

PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE CAREFULLY

PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING RACK SHALL BE

TRANSFERRED TO THE NEW SECOND LEVEL LOCATION ON THE NEW RACK.

CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING THE PROPOSED NEW

RACK ELEVATION AND PROVIDE A PHASING PLAN FOR TRANSFERRING ALL

EXISTING DEVICES TO REMAIN TO THE NEW RACKS.

PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK.

COORDINATE FIXTURES WITH OVERHEAD TRAY. SEE T-500 SERIES SHEETS FOR

ADDITIONAL REQUIREMENTS. COORDINATE LIGHT FIXTURES WITH OVERHEAD

CABLE TRAY.

PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. BASIS OF DESIGN WISENET

XNP-6320. MOUNT AT 8’ – 6” A.F.F. TO TOP OF WALL BRACKET. INTEGRATE

CAMERA INTO EXISTING VMS. PROVIDE CONTROLLABILITY THROUGH EXISTING IT

NETWORK.

PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

NEW 4” SPEED CONDUIT SLEEVE THROUGH WALL ABOVE CEILING GRID FOR

HORIZONTAL VOICE/DATA CABLING OR FIBER WITH PLASTIC BUSHINGS ON BOTH

ENDS TO PROTECT CABLES. FIRE CAULK PENETRATION PER SPECIFICATIONS.

EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

EXISTING WALL MOUNTED FIBER SPLICE WITH MULTI-MODE OPTICAL CABLE TO

BE PROTECTED IN PLACE UNTIL NEW SPEED FIBER IS INSTALLED. DEMOLISH

EXISTING FIBER SPLICE ONCE NEW SPEED CONDUIT SLEEVE AND FIBER ARE

OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN FOR

TRANSFERRING FIBER.

PROVIDE NEW iSTAR EDGE (ESTAR002) ACCESS CONTROL SYSTEM. INSTALL PER

MANUFACTURERS RECOMMENDATIONS.

ALL EXISTING ANALOG PHONE CABLE DEVICES AND TERMINATIONS ETC. SHALL

REMAIN OPERATIONAL AT ALL TIMES AND SHALL BE RETAINED AND REUSED.

PROTECT IN PLACE.

HORIZONTAL CABLE LENGTH LIMITATIONS PER STANDARD 3.1.

VERTICAL ROUTE FOR TELECOM RISER. SEAL ALL FLOOR PENETRATIONS TO

MAINTAIN FIRE RATING.

CONTRACTOR SHALL FIELD VERIFY EXISTING TELECOMMUNICATIONS EQUIPMENT

TO BE DEMOLISHED PRIOR TO COMMENCING WORK.

BATTERY AND UPS CABINET ENCLOSURE, SEE SHEET 01E-601 FOR ADDITIONAL

INFORMATION.

PROVIDE NEW 20" X 4" BONDING BAR, SET OF INSULATORS STAND-OFF

BRACKETS, AND STAINLESS STEEL SCREWS. PROVIDE ALL GROUNDING CABLE

AND CONNECTORS AND INSTALL PER TYPICAL DETAIL ON T-500 SERIES SHEETS.

PROVIDE INDOOR COMPUTER ROOM AIR CONDITIONER (CRAC) UNIT. NEW CRAC

UNITS SHALL BE INTEGRATED WITH FACILITY AUTOMATED LOGIC CONTROLS

BUILDING MANAGEMENT SYSTEM. COORDINATE FINAL LOCATION AND CRAC

DESIGNATION WITH COR.

PROVIDE NEW 16" X 4" BONDING BAR, SET OF INSULATORS STAND-OFF

BRACKETS, AND STAINLESS STEEL SCREWS. PROVIDE ALL GROUNDING CABLE

AND CONNECTORS AND INSTALL PER TYPICAL DETAIL ON T-500 SERIES SHEETS.

EXISTING PACS AND EQUIPMENT RACKS

FUTURE PACS/FMS HEAD-END EQUIPMENT

NEW INDOOR UNIT

NOTE: NOT ALL KEYNOTES

ARE USED ON EACH SHEET

SCALE: 1/2" = 1'-0"F8

TELECOMMUNICATION ENLARGED

PLAN - FIRST LEVEL - 2C-1121 -

EXISTING

SCALE: 1/2" = 1'-0"F6

TELECOMMUNICATION ENLARGED

PLAN - FIRST LEVEL - 2C-1156 -

EXISTING

SCALE: 1/2" = 1'-0"F4

TELECOMMUNICATION ENLARGED

PLAN - SECOND LEVEL - 2C-2139 -

EXISTING

SCALE: 1/2" = 1'-0"F1

TELECOMMUNICATION ENLARGED

PLAN - THIRD LEVEL - 2C-3143 -

EXISTING

MEDICAL

RECORDS

2E-B127

CORRIDOR

B043

TELECOM

ROOM

2E-B127A

161 SF

2E-B127A-CAM-1

FIBRE PATH A

(1) 24F OS2 CABLE

BLDG 2E (1) OS2 CABLE

FIBRE PATH B

(1) 24F OS2 CABLE

BLDG 65 (1) OS2 CABLE

3'

- 0

3' - 0"

TYP.

4'

- 9

3' - 6 1/2"

2E-B127A-B

2E-B127A-A

2E-B127A-D

2E-B127A-C

EXAM RM

2E-1159

TELECOM

ROOM

2E-1178

266 SF

CLEAN

UTILITY

2E-1164

MEDS

2E-1168

CORRIDOR

C1-34

STAFF

TOILET

2E-1180

TYP.

9 15

2E-1178-D

2E-1178-CAM-01

2E-1178-E

TYP.

FIBRE PATH B

(1) 24F OS2 CABLE

BLDG 65 (1) OS2 CABLE

FIBRE PATH A

(1) 24F OS2 CABLE

BLDG 2E (1) OS2 CABLE

3'

- 0

3' - 0"

6' - 8"

1/

2"

2E-1178-F

2E-1178-A

2E-1178-B

2E-1178-C

WAITING

2E-2128

220 SF

EXAM RM

2E-2142

N MGR

OFFICE

2E-2126

TELECOM

ROOM

2E-2149

141 SF

2E-2149-CAM-01

3'

- 8

3' - 0" 7' - 4 1/2"

3'

- 0

TYP.

3 3

2E-2149-A

2E-2149-B

2E-2149-C

2E-2149-D

TYP.

TYP.

CORRIDOR

2E-3027

COMPUTER

TRAINING

RM

2E-3112

TYP.

TELECOM

ROOM

2E-3113A

98 SF

HEARING

ROOM

2E-3113

17 3' - 0"

3' - 6 1/2"

2E-3113A-CAM-17

TYP.

2E-3113A-A

2E-3113A-B

2E-3113A-C

2E-3113A-D

1 3'

- 0

4'

- 1 1"

9'

- 1

1/

2"

8' - 11"

CORRIDOR

2E-4026

TYP.

TELECOM ROOM

2E-4115B

167 SF

2E-4115B-CAM-01

TYP.

3'

- 0

6' - 8" 3' - 0"

TYP.

2E-4115B-A

2E-4115B-B

2E-4115B-C

2E-4115B-C

TYP.

7'

- 7

/2

13' - 0 1/2"

7"

COMPUTER

RM

2E-5141

TELECOM

ROOM

2E-5142A

111 SF

2E-5142A-CAM-1

TYP.

17 3'

- 0

3' - 0" 3' - 0 1/2"

TYP.

6'

- 9

72E-5142A-A

2E-5142A-B

2E-5142A-C

2E-5142A-C

TYP.

TYP.

9' - 3 1/2"

8"

WALL SYMBOL LEGEND

EXISTING CONSTRUCTION TO REMAIN

SMOKE AND 1-HR RATED FIRE

BARRIER AND OPENINGS

SMOKE AND 2-HR RATED FIRE BARRIER

AND OPENINGS

SMOKE BARRIER AND OPENINGS

1 HR RATED FIRE BARRIER AND

OPENINGS

2 HR RATED FIRE BARRIER AND OPENINGS

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

FIBER PATH A

FIBER PATH B

FIBER PATH LEGEND

SERVICE PROVIDER A

SERVICE PROVIDER B

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:4

02T-403

TELECOMMUNICATION ENLARGED PLANS- B2E 689A4-22-700

01_02

07/03/2024 M. Perkins N. Wicklund

ISSUED FOR

CONSTRUCTION

EHRM…