Attachment 13 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part4.pdf

PDF 12 MB Posted

Attached to
Z2DA--689A4-22-700 EHRM Infrastructure, Newington CONSTRUCTION SOLICITATION (VA-24-00028377)
Solicitation number
36C77624B0015_1
Issued by

View the file

Other files

File Type Posted
Technical Questions Tracking Spreadsheet - 2-13-25 - 36C77624B0015 - Construct EHRM Infrastructure Upgrades Newington CT.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0007.pdf PDF
Attachment 34 - 689A4-22-700.EHRM.Newington.Add3.20250211.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0006.pdf PDF
Attachment 27 - Wage Rates 01.31.25- Hartford.pdf PDF
Bid Opening Details - Newington CT - 36C76624B0015.pdf PDF
Site Visit Sign In Sheet 2.3.25.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0005.pdf PDF
Attachment 33 - Site Visit Instructions - Updated 1.27.25.pdf PDF
Attachment 2 - 689A4-22-700.EHRM.Newington.Spec.Final.20240806.Part1.pdf PDF
Attachment 21 - 689A4-22-700.Newington.EHRM.IFC.B32_33_34.20240703.part2.pdf PDF
Attachment 17 - 689A4-22-700.Newington.EHRM.IFC.B03_42.20240703.part2.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0004.pdf PDF
Attachment 22 - 689A4-22-700.Newington.EHRM.IFC.B65.20240703.part1.pdf PDF
Attachment 32 - 689A4-22-700.EHRM.Newington -.20250114 - Addendum 2.pdf PDF
Attachment 3 - 689A4-22-700.EHRM.Newington.Spec.Final.20240806.Part2.pdf PDF
Attachment 12 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part3.pdf PDF
Attachment 15 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part6.pdf PDF
Attachment 20 - 689A4-22-700.Newington.EHRM.IFC.B32_33_34.20240703.part1.pdf PDF
Attachment 33 - Site Visit Instructions - Updated 1.23.25.pdf PDF
Attachment 18 - 689A4-22-700.Newington.EHRM.IFC.B03_42.20240703.part3.pdf PDF
Attachment 23 - 689A4-22-700.Newington.EHRM.IFC.B65.20240703.part2.pdf PDF
Attachment 19 - 689A4-22-700.Newington.EHRM.IFC.B12.20240703.pdf PDF
Attachment 14 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part5.pdf PDF
Attachment 10 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part1.pdf PDF
Technical Questions Tracking Spreadsheet - 1-23-25 - 36C77624B0015 - Construct EHRM Infrastructure Upgrades Newington CT .pdf PDF
Attachment 16 - 689A4-22-700.Newington.EHRM.IFC.B03_42.20240703.part1.pdf PDF
Attachment 24 - 689A4-22-700.Newington.EHRM.IFC.SITE.20240703.pdf PDF
Attachment 11 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part2.pdf PDF
Attachment 31 - EHRM Newington-Pre Bid Presentation.010725.R02.pdf PDF
Technical Questions Tracking Spreadsheet - 1-6-25 - 36C77624B0015 - Construct EHRM Infrastructure Upgrades Newington CT.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0003.pdf PDF
2025-01-07 Preproposal conference sign in list.pdf PDF
Attachment 30 - Price Schedule - 36C77624B0015 - 689A4-22-700 EHRM Infrastructure Newington.pdf PDF
Attachment 28 - Site Visit Instructions - Updated 1.6.25.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0002.pdf PDF
Attachment 19 - Newington EHRM Drawings - Part 10 of 16 - 12.31.24.pdf PDF
Newington EHRM Infrastructure Upgrades - 36C77624B0015 Amendment - 0001.pdf PDF
Attachment 29 - 689A4-22-700.EHRM.Newington.Add1.20241213.pdf PDF
Attachment 28 - Site Visit Instructions.pdf PDF
Attachment 24 - Newington EHRM Drawings - Part 15 of 16.pdf PDF
Attachment 11 - Newington EHRM Drawings - Part 2 of 16.pdf PDF
Attachment 26 - Newington VAHC campus map.pdf PDF
Attachment 22 - Newington EHRM Drawings - Part 13 of 16.pdf PDF
Attachment 23 - Newington EHRM Drawings - Part 14 of 16.pdf PDF
Attachment 3 - 689A4-22-700.EHRM.Newington.Spec.Final.20240806.Part2.pdf PDF
Attachment 14 - Newington EHRM Drawings - Part 5 of 16.pdf PDF
Attachment 10 - Newington EHRM Drawings - Part 1 of 16.pdf PDF
Attachment 27 - Wage Rates 8.9.24- Hartford.pdf PDF
Attachment 9 - Underground Utility Locating.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B2C-TR2C-2139A

208/120V

125A-PANEL

60A-MCB

B2C-TR2C-2139B

208/120V

125A-PANEL

60A-MCB

B2C-TR2C-3140A

208/120V

125A-PANEL

60A-MCB

B2C-TR2C-3140B

208/120V

125A-PANEL

60A-MCB

B2C-TR2C-1155A

208/120V

125A-PANEL

60A-MCB

B2C-TR2C-1155B

208/120V

125A-PANEL

60A-MCB

B2W-TR2W-121B

208/120V

125A-PANEL

100A-MCB

B2W-TR2W-121A

208/120V

125A-PANEL

100A-MCB

FIRST LEVEL

60A

NON-FUSED

DISCONNECT

THIRD LEVEL

SECOND LEVEL

125A 3P 7 50A

3P 7

ROOM 2C-1155

ROOM 2C-2139

ROOM 2C-3140A

60A 3P

60A 3P

60A 3P

60A 3P

60A 3P

60A 3P

(NEW) EMERGENCY DISTRIBUTION BOARD

B2C-EP-TR, 225A, 208/120V, 3PH, 4W

(NEW) NORMAL DISTRIBUTION BOARD

B2C-NP-TR, 225A, 208/120V, 3PH, 4W

2 2 225A 3P

100A 3P 77

100A 3P

100A 3P

ROOM 2W-121ROOM 2W-121

77777777

9 9

99 9 9

9 9

10 10

125A

NON-FUSED

DISCONNECT

30KVA TRANSFORMER "T-2C-TR-A"

480V-208/120V, 3PH, 4W, 115°C

COPPER WINDINGS

#1/0

112.5KVA TRANSFORMER "T-2C-TR-B"

480V-208/120V, 3PH, 4W, 115°C

COPPER WINDINGS

#1/0

100A

NON-FUSED

DISCONNECT

225A

NON-FUSED

DISCONNECT

(E) 2C-EQDP2C-MB

225A, 480/277V, 3PH, 4W 1 (E) 2C-MDP

1200A, 480/277V, 3PH, 4W 1

FEEDER & BRANCH CIRCUIT SIZING SCHEDULE -

GENERAL PURPOSE

2/0 6 1 1/2" 2" 2"

1 1/2"

2 1/2"

2-2 1/2"

3-2 1/2"

4-2 1/2"

5-2 1/2"

6-2 1/2"

2-500

2-600

3-400

4-350

5-400

6-400

5-4/0

6-250

2-1/0

2-1/0

3-2/0

4-3/0

2-3"

2-3"

3/0

4/0

2-4/0

2-250

2-350

3"3

2-2

2-2

2-1

3 3"

2-2"

2-2"

2"

2"

6-3"

3-3"

4-3"

5-3"

2-3"

2-3"

6-3"

2-3 1/2"

3-3"

4-3"

5-3"

2-4"

3"

2-2 1/2"

4"

2-2"

2-3"

2 1/2"

3"

2"

2"

3 1/2"

2-2 1/2"

2-3"

4"

2-2 1/2"

2 1/2"

3"

2"

2 1/2"

3/4"(1")

3/4"(1")

3/4"

3/4"

3/4"

3/4"

1"(1 1/4")

1 1/4"

1 1/4"

1 1/4"

2 WIRE

8(6)

6(4)

6(4)

4(2)

3(2)

2(1)

1/0

1(1/0)

8 1"

PHASE

& NEUTRAL

WIRE SIZE - AWG OR KCMIL

E.G.

3/4" 3/4"

1 1/4"(1 1/2")1 1/4"(1 1/2")

1 1/2"

1 1/2"

1 1/4"

3/4"(1")

3/4"(1")

3/4"

1"(1 1/4")

2"

1 1/2"(2")

1 1/4"

1"(1 1/4")

1"(1 1/4")

1 1/4"

3/4"(1")

CONDUIT SIZE

3/4"

3/4"

3 WIRE

3/4"

3/4"

4 WIRE

(3PH & 1N) NOTE

1.

2.

3.

4.

CIRCUIT MAXIMUM DISTANCE IS BASED ON

NEC CHAPTER 9, TABLE 8 CONDUCTOR

PROPERTIES FOR COATED COPPER

CONDUCTORS AT 75 DEGREES CELSIUS.

MAXIMUM CIRCUIT LOAD FOR DISTANCE IS

BASED ON NEC 220-10(b)

BASED ON THHN/THWN, 90°., 600V.,

INSULATED, COPPER WIRE APPLIED AT 75°FOR

TERMINATIONS RATED AT 60°C/75°C AND 75°C.

FOR TERMINATIONS RATED AT 60°C PROVIDE

WIRE AND CONDUIT SIZES INDICATED IN

PARENTHESIS.

BASED ON WIRE OUTSIDE DIAMETERS AND

RIGID METALLIC CONDUIT INSIDE DIAMETERS

AS PROVIDED IN THE NEC. DO NOT REDUCE

CONDUIT SIZE FOR NON-RIGID METALLIC

APPLICATION. REFER TO NEC FOR CONDUIT

TYPES MORE RESTRICTIVE THAN RIGID

METALLIC.

NOTES:

(NOTES 1 & 2)

120V. SINGLE PHASE CIRCUIT LENGTH TABLE 208V. THREE PHASE CIRCUIT LENGTH TABLE

LOAD

(VOLT-AMPS)

MAX.

CIRCUIT

17280

14400

11520

(AMPS)

AMPACITY

BREAKER

CURRENT

(AMPS)

MAX.

CIRCUIT

NO.8

MAXIMUM LENGTH IN FEET

- 58

110 174

NO.12

NO.10

73 116

117-

NO.4

NO.6

(AMPS)

BREAKER

AMPACITY

LOAD

(VOLT-AMPS)

CIRCUIT

MAX.

CURRENT

(AMPS)

CIRCUIT

MAX.

234-- --

116-

NO.10

NO.12

233127

294 468

177 281

221 351139

NO.6

NO.4

NO.8

MAXIMUM LENGTH IN FEET

35-40

45-50

80-90

15-20

25-30

OVERCURRENT

DEVICE RATING

(AMPERES)

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:2

02E-601

ELECTRICAL ONE-LINE DIAGRAMS - B2C 689A4-22-700

01_02

07/03/2024 M. Perkins J. Schooley

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

1.

2.

3.

4.

5.

CONTRACTOR SHALL PROVIDE A 30 DAY LOAD MEASUREMENT OF

EQUIPMENT INDICATED AND PROVIDE THE RESULTS TO THE

ELECTRICAL ENGINEER OF RECORD (EEOR) TO VERIFY THE

EQUIPMENT HAS CAPACITY TO SUPPORT ADDITIONAL LOAD.

PROVIDE SPD DEVICE INTEGRATED INTO PANEL BOARD. REQUIRES

THREE PHASES.

PROVIDE SUB-METERING OF NEW DEDICATED TR, IT LOAD ONLY.

CIRCUITS SHALL BE EQUIPPED WITH NEW MONITORED POWER

METER INTEGRATED INTO PANEL. BASIS OF DESIGN: EATON OR

SQUARE D.

PROVIDE SUB-METERING OF NEW DEDICATED ROOM HVAC

SYSTEM(S). CIRCUITS SHALL BE EQUIPPED WITH NEW MONITORED

POWER METER INTEGRATED INTO PANEL. BASIS OF DESIGN: EATON

OR SQUARE D.

PROVIDE 100% RATED CIRCUIT BREAKER

6. PROVIDE NEW FEED BASE ON LOAD INDICATED.

REFER TO SHEET E-701 FOR SIZING.

7. PROVIDE CIRCUIT BREAKER INDICATED IN AVAILABLE SPACE.

8. DISTRIBUTION BOARD BEING REPLACED.

9. NEW PANELBOARD TO HAVE PXR20 SERIES BASIS OF DESIGN OR

SIMILAR ELECTRONIC TRIP CIRCUIT BREAKER AND BE

COORDINATED. COORDINATION STUDY TO BE SUBMITTED PRIOR

TO MAIN BREAKER SELECTION.

10. PROVIDE 100% RATED MAIN BREAKER

ALL NEW FEEDER CONDUCTORS SHALL BE CONTINUOUS WITH NO

SPLICES.

ALL FEEDERS SHALL BE COPPER WITH 90° C. (THHN/THWN)

INSULATION.

NEW CIRCUIT BREAKERS SHALL BE TYPE TO MATCH EXISTING, U.N.O.

PROVIDE ALL REQUIRED MOUNTING HARDWARE, LUGS AND

COVERPLATES FOR A COMPLETE INSTALLATION.

FEEDER VOLTAGE DROP CALCULATIONS ARE INDICATED FOR

FEEDERS EXCEEDING 100'-0".

CONTRACTOR TO PROVIDE SHORT CIRCUIT, OVERCURRENT

PROTECTIVE DEVICE COORDINATION AND ARC FLASH ANALYSIS FOR

ALL NEW PANELS, SWITCHBOARDS AND SWITCHGEAR. STUDY SHALL

INCLUDE EXISTING SYSTEM TO THE EXTENT THAT THE FAULT

CURRENT, COORDINATION AND ARC FLASH PREPARED IN

COMPLIANCE WITH 2018 NFPA 70E FOR THE NEW PANELS CAN BE

CALCULATED. CONTRACTOR IS RESPONSIBLE FOR ALL DATA

COLLECTION REQUIRED TO COMPLETE THE ANALYSIS. REPORT OF

THE ANALYSIS SHALL BE PREPARED SUMMARIZING THE INPUT DATA,

SINGLE-LINE USED IN CALCULATION, AND RESULTS INCLUDING ARC

FLASH LABELS. REPORT SHALL BE STAMPED AND SIGNED BY

PROFESSIONAL ENGINEER UNDER WHOSE DIRECTION THE STUDY

WAS PERFORMED. CONTRACTOR TO INSTALL ARC FLASH LABELS ON

PANELS IN COMPLIANCE WITH 2018 NFPA 70E. ELECTRICAL

EQUIPMENT SUBMITTALS SHALL REFLECT RESULTS OF SHORT

CIRCUIT ANALYSIS. CONTRACTOR SHALL SET ALL ADJUSTABLE

CIRCUIT BREAKERS PER OVERCURRENT PROTECTIVE DEVICE

STUDY. MINIMAL INFORMATION INCLUDED ON ARC FLASH LABELS

INCLUDE:

• NOMINAL SYSTEM VOLTAGE

• ARC FLASH BOUNDARY

• AT LEAST ONE OF THE FOLLOWING:

A. EITHER THE AVAILABLE INCIDENT ENERGY AND THE

CORRESPONDING WORKING DISTANCE, OR THE ARC FLASH

PPE CATEGORY FOR THE EQUIPMENT, BUT NOT BOTH.

B. MINIMUM ARC RATING OF CLOTHING.

C. SITE-SPECIFIC LEVEL OF PPE.

ANALYSIS SHALL BE PREPARED PRIOR TO OR CONCURRENT WITH

ELECTRICAL SWITCHGEAR, SWITCHBOARDS AND PANEL

SUBMITTALS. EQUIPMENT SUBMITTALS WITHOUT ANALYSIS SHALL

BE REJECTED AND NOT REVIEWED.

EEOR CAN NOT BE RESPONSIBLE FOR ANALYSIS UNLESS

SEPARATELY AND SPECIFICALLY CONTRACTED TO DO SO.

CONTRACTOR SHALL PROVIDE A 30 DAY LOAD MEASUREMENT OF

EQUIPMENT INDICATED AND PROVIDE THE RESULTS TO THE

ELECTRICAL ENGINEER OF RECORD (EEOR) TO VERIFY THE

EQUIPMENT HAS CAPACITY TO SUPPORT ADDITIONAL LOAD.

NOTE: NOT ALL KEYNOTES

ARE USED ON EACH SHEET.

Revisions: Date:

B2E-TR2E-1178A

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-1178B

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-2149A

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-2149B

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-B127AA

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-B127AB

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-3113AB

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-3113AA

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-4115BB

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-4115BA

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-5142AA

208/120V

125A-PANEL

60A-MCB

B2E-TR2E-5142AB

208/120V

125A-PANEL

60A-MCB

HVAC-B2E

208/120V

225A-PANEL

225A-MCB

MCR-EP

208/120V

125A-PANEL

60A-MCB

SECOND LEVEL

FIRST LEVEL

BASEMENT LEVEL

2E-EDP2E-MCR

600A, 480/277V, 3PH, 4W 1(E) 2E-MDP-W

2000A, 480/277V, 3PH, 4W1

ROOM 2E-B127A

ROOM 2E-1178

ROOM 2E-2149

60A 3P

60A 3P

60A 3P

60A 3P

60A 3P

60A 3P

(NEW) EMERGENCY DISTRIBUTION BOARD

B2E-EP-TR, 400A, 208/120V, 3PH, 4W

(NEW) EMERGENCY DISTRIBUTION BOARD

B2E-NP-TR, 225A, 208/120V, 3PH, 4W

2 2 400A 3P

225A 3P 77

60A 3P

60A 3P

THIRD LEVEL

ROOM 2E-3113A

FOURTH LEVEL

60A 3P

60A 3P

FIFTH LEVEL

60A 3P

60A 3P

ROOM 2E-4115B

ROOM 2E-5142A

175A 3P 7

150KVA TRANSFORMER "T-2E-TR-B"

480V-208/120V, 3PH, 4W, 115°C

COPPER WINDINGS

125A 3P 7

75KVA TRANSFORMER "T-2E-TR-A"

480V-208/120V, 3PH, 4W, 115°C

COPPER WINDINGS

ROOM 2E-1161B ROOM 2E-1161

225A 3P

7777777777777

#1/0 #1/0

60A 3P

ROOM 1C-148D

9 9

9 9

9 9

9 9 9

9 9 10 10

10 10

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:2

02E-602

ELECTRICAL ONE-LINE DIAGRAMS - B2E 689A4-22-700

01_02

07/03/2024 M. Perkins J. Schooley

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

1.

2.

3.

4.

5.

CONTRACTOR SHALL PROVIDE A 30 DAY LOAD MEASUREMENT OF

EQUIPMENT INDICATED AND PROVIDE THE RESULTS TO THE

ELECTRICAL ENGINEER OF RECORD (EEOR) TO VERIFY THE

EQUIPMENT HAS CAPACITY TO SUPPORT ADDITIONAL LOAD.

PROVIDE SPD DEVICE INTEGRATED INTO PANEL BOARD. REQUIRES

THREE PHASES.

PROVIDE SUB-METERING OF NEW DEDICATED TR, IT LOAD ONLY.

CIRCUITS SHALL BE EQUIPPED WITH NEW MONITORED POWER

METER INTEGRATED INTO PANEL. BASIS OF DESIGN: EATON OR

SQUARE D.

PROVIDE SUB-METERING OF NEW DEDICATED ROOM HVAC

SYSTEM(S). CIRCUITS SHALL BE EQUIPPED WITH NEW MONITORED

POWER METER INTEGRATED INTO PANEL. BASIS OF DESIGN: EATON

OR SQUARE D.

PROVIDE 100% RATED CIRCUIT BREAKER

6. PROVIDE NEW FEED BASE ON LOAD INDICATED.

REFER TO SHEET E-701 FOR SIZING.

7. PROVIDE CIRCUIT BREAKER INDICATED IN AVAILABLE SPACE.

8. DISTRIBUTION BOARD BEING REPLACED.

9. NEW PANELBOARD TO HAVE PXR20 SERIES BASIS OF DESIGN OR

SIMILAR ELECTRONIC TRIP CIRCUIT BREAKER AND BE

COORDINATED. COORDINATION STUDY TO BE SUBMITTED PRIOR

TO MAIN BREAKER SELECTION.

10. PROVIDE 100% RATED MAIN BREAKER

ALL NEW FEEDER CONDUCTORS SHALL BE CONTINUOUS WITH NO

SPLICES.

ALL FEEDERS SHALL BE COPPER WITH 90° C. (THHN/THWN)

INSULATION.

NEW CIRCUIT BREAKERS SHALL BE TYPE TO MATCH EXISTING, U.N.O.

PROVIDE ALL REQUIRED MOUNTING HARDWARE, LUGS AND

COVERPLATES FOR A COMPLETE INSTALLATION.

FEEDER VOLTAGE DROP CALCULATIONS ARE INDICATED FOR

FEEDERS EXCEEDING 100'-0".

CONTRACTOR TO PROVIDE SHORT CIRCUIT, OVERCURRENT

PROTECTIVE DEVICE COORDINATION AND ARC FLASH ANALYSIS FOR

ALL NEW PANELS, SWITCHBOARDS AND SWITCHGEAR. STUDY SHALL

INCLUDE EXISTING SYSTEM TO THE EXTENT THAT THE FAULT

CURRENT, COORDINATION AND ARC FLASH PREPARED IN

COMPLIANCE WITH 2018 NFPA 70E FOR THE NEW PANELS CAN BE

CALCULATED. CONTRACTOR IS RESPONSIBLE FOR ALL DATA

COLLECTION REQUIRED TO COMPLETE THE ANALYSIS. REPORT OF

THE ANALYSIS SHALL BE PREPARED SUMMARIZING THE INPUT DATA,

SINGLE-LINE USED IN CALCULATION, AND RESULTS INCLUDING ARC

FLASH LABELS. REPORT SHALL BE STAMPED AND SIGNED BY

PROFESSIONAL ENGINEER UNDER WHOSE DIRECTION THE STUDY

WAS PERFORMED. CONTRACTOR TO INSTALL ARC FLASH LABELS ON

PANELS IN COMPLIANCE WITH 2018 NFPA 70E. ELECTRICAL

EQUIPMENT SUBMITTALS SHALL REFLECT RESULTS OF SHORT

CIRCUIT ANALYSIS. CONTRACTOR SHALL SET ALL ADJUSTABLE

CIRCUIT BREAKERS PER OVERCURRENT PROTECTIVE DEVICE

STUDY. MINIMAL INFORMATION INCLUDED ON ARC FLASH LABELS

INCLUDE:

• NOMINAL SYSTEM VOLTAGE

• ARC FLASH BOUNDARY

• AT LEAST ONE OF THE FOLLOWING:

A. EITHER THE AVAILABLE INCIDENT ENERGY AND THE

CORRESPONDING WORKING DISTANCE, OR THE ARC FLASH

PPE CATEGORY FOR THE EQUIPMENT, BUT NOT BOTH.

B. MINIMUM ARC RATING OF CLOTHING.

C. SITE-SPECIFIC LEVEL OF PPE.

ANALYSIS SHALL BE PREPARED PRIOR TO OR CONCURRENT WITH

ELECTRICAL SWITCHGEAR, SWITCHBOARDS AND PANEL

SUBMITTALS. EQUIPMENT SUBMITTALS WITHOUT ANALYSIS SHALL

BE REJECTED AND NOT REVIEWED.

EEOR CAN NOT BE RESPONSIBLE FOR ANALYSIS UNLESS

SEPARATELY AND SPECIFICALLY CONTRACTED TO DO SO.

CONTRACTOR SHALL PROVIDE A 30 DAY LOAD MEASUREMENT OF

EQUIPMENT INDICATED AND PROVIDE THE RESULTS TO THE

ELECTRICAL ENGINEER OF RECORD (EEOR) TO VERIFY THE

EQUIPMENT HAS CAPACITY TO SUPPORT ADDITIONAL LOAD.

NOTE: NOT ALL KEYNOTES

ARE USED ON EACH SHEET.

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:2

02E-603

ELECTRICAL ONE-LINE DIAGRAMS 689A4-22-700

01_02

07/03/2024 M. Perkins J. Schooley

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

REFER TO 02E-604

REFER TO 02E-605 REFER TO 02E-605

(NEW)

175A 3P

150KVA T-2E-TR-A

480V-120/208V, 3PH, 4W

225A 3P

B2E-NP-TR

B2E-

TR2E-2149A

B2E-

TR2E-4155A

B2E-TR2E-

B127AA

B2E-

TR2E-3113AA

B2E-TR2E-4115BA

B2E-TR2E-1178A

30KVA T-2C-TR-A

480V-208/120V, 3PH, 4W

50A 3P

225A 3P

Revisions: Date:

B2C-NP-TR

B2C-TR2C-3140A

60A

B2C-TR2C-1155A

60A

B2C-TR2C-2138DA

60A

B2W-TR2W-121A

100A

(NEW)

FROM CBL-2W-ATS-EQ-N

SHEET E3

FROM CBL-2W-ATS-LS-N

SHEET E3

FROM CBL-2W-ATS-EQ-N

SHEET E3

FROM CBL-2C-ATS-LSDP2C-N

SHEET E3

FROM CBL-2C-ATS-CRDP2C-N

SHEET E3

FROM CBL-2C-ATS-EQDP2C-N

SHEET E3

FROM CBL-01-ATS-FP-01-N

SHEET E4

FROM CBL-11-ATS-FP-03-N

SHEET E5

INFO FOR THIS MB COULD

NOT BE OBTAINED.

FROM CBL-2E-ATS-6-N

SHEET E4

FROM CBL-2E-L2EATS-N

SHEET E3

FROM CBL-2E-CR2EATS-N

SHEET E3 FROM CBL-2E-EQ2EATS-N

SHEET E3

INFO FOR THIS MB COULD

NOT BE OBTAINED.

2E-GEN-11

937.5 kVA 480 V

CBL-2E-GEN-11-MB

(4) 350 AWG/kcmil 10 ft Magnetic

2E-GEN-11-MB

1200A Frame 1200A Trip 1200A Plug

CBL-2E-EDP2E

(4) 350 AWG/kcmil 10 ft Magnetic

2E-EDP2E

480V Isc 3P: 7457A Isc SLG:7431A

2E-EDP2E-1

100A Frame 100A Trip

2E-EDP2E-2

600A Frame 600A Trip

2E-EDP2E-3

600A Frame 600A Trip

CBL-2E-LS2EATS-E

(1) 2 AWG/kcmil 35 ft Magnetic

CBL-2E-CR2EATS-E

(2) 350 AWG/kcmil 25 ft Magnetic

CBL-2E-EQ2EATS-E

(3) 500 AWG/kcmil 15 ft Magnetic

E N

2E-LS2EATS

E N

2E-CR2EATS

E N

2E-EQ2EATS

CBL-2E-LS2EATS

(1) 2 AWG/kcmil 35 ft Magnetic

2E-LS2EDP

480V Isc 3P: 10163A Isc SLG:7275A

2E-LS2EDP-1

50A Frame 50A Trip

2E-LS2EDP-2

50A Frame 50A Trip

2E-LS2EDP-3

50A Frame 50A Trip

2E-LS2EDP-4

50A Frame 50A Trip

2E-LS2EDP-5

50A Frame 50A Trip

2E-LS2EDP-6

50A Frame 50A Trip

2E-LS2EDP-7

15A Frame 15A Trip

CBL-2E-EH1A

(1) 4 AWG/kcmil 145 ft Magnetic

2E-EH1A

480V Isc 3P: 3852A Isc SLG:2368A

CBL-2E-EH4C

(1) 2 AWG/kcmil 360 ft Magnetic

2E-EH4C

480V Isc 3P: 2752A Isc SLG:1677A

CBL-2E-EH2A

(1) 4 AWG/kcmil 145 ft Magnetic

2E-EH2A

480V Isc 3P: 3852A Isc SLG:2368A

CBL-2E-EH4A

(1) 4 AWG/kcmil 200 ft Magnetic

2E-EH4A

480V Isc 3P: 3092A Isc SLG:1878A

CBL-2E-EH2C

(1) 4 AWG/kcmil 310 ft Magnetic

2E-EH2C

480V Isc 3P: 2212A Isc SLG:1327A

CBL-2E-TR-EL1N

(1) 12 AWG/kcmil 20 ft Magnetic

2E-EH1A-1

30A Frame 30A Trip

CBL-2E-EHBA

(1) 6 AWG/kcmil 50 ft Magnetic

2E-EHBA

480V Isc 3P: 2857A Isc SLG:1726A

2E-EH4C-1

30A Frame 30A Trip

CBL-2E-EH5C

(1) 6 AWG/kcmil 10 ft Magnetic

2E-EH5C

480V Isc 3P: 2623A Isc SLG:1594A

2E-EH5C-1

15A Frame 15A Trip

CBL-2E-TR-ELPP

(1) 12 AWG/kcmil 90 ft Magnetic

S

P 2E-TR-ELPP

9.0 kVA Pri. 480 V Sec. 208 V

2.96 %Z

CBL-2E-ELPP

(1) 10 AWG/kcmil 6 ft Magnetic

2E-ELPP-MB

40A Frame 40A Trip

2E-ELPP

208V Isc 3P: 666A Isc SLG:702A

2E-EH2A-1

30A Frame 30A Trip

CBL-2E-EH3A

(1) 6 AWG/kcmil 10 ft Magnetic

2E-EH3A

480V Isc 3P: 3603A Isc SLG:2205A

CBL-2E-EH1C

(1) 4 AWG/kcmil 295 ft Magnetic

2E-EH1C

480V Isc 3P: 2302A Isc SLG:1382A

2E-EH1C-1

30A Frame 30A Trip

CBL-2E-EHBC

(1) 6 AWG/kcmil 10 ft Magnetic

2E-EHBC

480V Isc 3P: 2209A Isc SLG:1325A

2E-EH4A-1

30A Frame 30A Trip

CBL-2E-EH5A

(1) 6 AWG/kcmil 10 ft Magnetic

2E-EH5A

480V Isc 3P: 2928A Isc SLG:1773A

2E-EH2C-1

30A Frame 30A Trip

CBL-2E-EH3C

(1) 6 AWG/kcmil 10 ft Magnetic

2E-EH3C

480V Isc 3P: 2126A Isc SLG:1274A

S

P 2E-TR-ELIN

9.0 kVA Pri. 480 V Sec. 208 V

2.96 %Z

CBL-2E-EL1N

(1) 6 AWG/kcmil 6 ft Magnetic

2E-EL1N-MB

80A Frame 80A Trip

2E-EL1N

208V Isc 3P: 790A Isc SLG:798A

CBL-2E-CR2EATS

(2) 350 AWG/kcmil 25 ft Magnetic

2E-CR2EDP

480V Isc 3P: 16399A Isc SLG:15425A

2E-CR2EDP-1

60A Frame 60A Trip

2E-CR2EDP-2

100A Frame 100A Trip

2E-CR2EDP-3

100A Frame 100A Trip

2E-CR2EDP-4

100A Frame 100A Trip

2E-CR2EDP-5

150A Frame 150A Trip

2E-CR2EDP-6

60A Frame 60A Trip

2E-CR2EDP-7

100A Frame 100A Trip

2E-CR2EDP-8

100A Frame 100A Trip

2E-CR2EDP-9

100A Frame 100A Trip

2E-CR2EDP-10

150A Frame 150A Trip

CBL-2E-CH2B

(1) 6 AWG/kcmil 300 ft Magnetic

2E-CH2B

480V Isc 3P: 1714A Isc SLG:1017A

CBL-2E-CH2C

(1) 2 AWG/kcmil 310 ft Magnetic

2E-CH2C

480V Isc 3P: 3676A Isc SLG:2282A

CBL-2E-CH1A

(1) 2 AWG/kcmil 170 ft Magnetic

2E-CH1A

480V Isc 3P: 5917A Isc SLG:3846A

CBL-2E-CH2A

(1) 2 AWG/kcmil 160 ft Magnetic

2E-CH2A

480V Isc 3P: 6180A Isc SLG:4042A

CBL-2E-CH4A

(1) 3/0 AWG/kcmil 195 ft Magnetic

2E-CH4A

480V Isc 3P: 8340A Isc SLG:6054A

CBL-2E-CH1B

(1) 2 AWG/kcmil 220 ft Magnetic

2E-CH1B

480V Isc 3P: 4868A Isc SLG:3092A

CBL-2E-CH1C

(1) 2 AWG/kcmil 320 ft Magnetic

2E-CH1C

480V Isc 3P: 3578A Isc SLG:2217A

CBL-2E-CH4C

(1) 2 AWG/kcmil 390 ft Magnetic

2E-CH4C

480V Isc 3P: 3013A Isc SLG:1849A

CBL-2E-CH3B

(1) 3/0 AWG/kcmil 310 ft Magnetic

2E-CH3B

480V Isc 3P: 6335A Isc SLG:4363A

2E-CH2B-1

30A Frame 30A Trip

CBL-2E-TR-CL2B

(1) 10 AWG/kcmil 6 ft Magnetic

S

P 2E-TR-CL2B

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2E-CL2B

(1) 8 AWG/kcmil 6 ft Magnetic

2E-CL2B-MB

50A Frame 50A Trip

2E-CL2B

208V Isc 3P: 1138A Isc SLG:1204A

2E-CH2C-1

30A Frame 30A Trip

2E-CH2C-2

60A Frame 60A Trip

CBL-2E-TR-CL2C

(1) 10 AWG/kcmil 6 ft Magnetic

CBL-2E-TR-CH3C

(1) 6 AWG/kcmil 10 ft Magnetic

2E-CH3C

480V Isc 3P: 3453A Isc SLG:2132A

S

P 2E-TR-CL2C

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2E-CL2C

(1) 8 AWG/kcmil 6 ft Magnetic

2E-CL2C-MB

50A Frame 50A Trip

2E-CL2C

208V Isc 3P: 1258A Isc SLG:1289A

2E-CH1A-1

50A Frame 50A Trip

2E-CH1A-2

80A Frame 80A Trip

CBL-2E-TR-CL1A

(1) 6 AWG/kcmil 6 ft Magnetic

CBL-2E-TR-CHBA

(1) 2 AWG/kcmil 40 ft Magnetic

2E-CHBA

480V Isc 3P: 5048A Isc SLG:3219A

S

P 2E-TR-CL1A

30.0 kVA Pri. 480 V Sec. 208 V

7.80 %Z

CBL-2E-CL1A

(1) 2 AWG/kcmil 6 ft Magnetic

2E-CL1A-MB

225A Frame 150A Trip

2E-CL1A

208V Isc 3P: 994A Isc SLG:1011A

2E-CH2A-1

50A Frame 50A Trip

2E-CH2A-2

80A Frame 80A Trip

CBL-2E-TR-CL2A

(1) 6 AWG/kcmil 6 ft Magnetic

CBL-2E-TR-CH3A

(1) 2 AWG/kcmil 10 ft Magnetic

2E-CH3A

480V Isc 3P: 5917A Isc SLG:3846A

S

P 2E-TR-CL2A

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2E-CL2A

(1) 8 AWG/kcmil 6 ft Magnetic

2E-CL2A-MB

50A Frame 50A Trip

2E-CL2A

208V Isc 3P: 1322A Isc SLG:1333A

CBL-2E-EQ2EATS

(3) 500 AWG/kcmil 15 ft Magnetic

2E-EQ2EDP

480V Isc 3P: 22187A Isc SLG:19767A

2E-EQ2EDP-1

60A Frame 60A Trip

2E-EQ2EDP-2

100A Frame 100A Trip

2E-EQ2EDP-3

100A Frame 100A Trip

2E-EQ2EDP-4

250A Frame 250A Trip

2E-EQ2EDP-10

300A Frame 300A Trip

2E-EQ2EDP-6

80A Frame 80A Trip

2E-EQ2EDP-7

100A Frame 100A Trip

2E-EQ2EDP-8

100A Frame 100A Trip

2E-EQ2EDP-9

225A Frame 225A Trip

2E-EQ2EDP-5

350A Frame 350A Trip

CBL-2E-QH1N

(1) 6 AWG/kcmil 15 ft Magnetic

2E-QH1N

480V Isc 3P: 16493A Isc SLG:12298A

CBL-2E-QH1C

(1) 2 AWG/kcmil 295 ft Magnetic

2E-QH1C

480V Isc 3P: 4021A Isc SLG:2453A

CBL-2E-QH1A

(1) 2 AWG/kcmil 155 ft Magnetic

2E-QH1A

480V Isc 3P: 6906A Isc SLG:4369A

CBL-2E-QMCC1

(1) 4/0 AWG/kcmil 110 ft Magnetic

2E-QMCC1

480V Isc 3P: 13944A Isc SLG:10439A

CBL-2E-QMCC2

(1) 350 AWG/kcmil 350 ft Magnetic

2E-QMCC2

480V Isc 3P: 8802A Isc SLG:6052A

CBL-2E-QHSW

(1) 2 AWG/kcmil 200 ft Magnetic

2E-QHSW

480V Isc 3P: 5621A Isc SLG:3496A

CBL-2E-QH4C

(1) 2 AWG/kcmil 345 ft Magnetic

2E-QH4C

480V Isc 3P: 3494A Isc SLG:2119A

CBL-2E-QH4A

(1) 2 AWG/kcmil 185 ft Magnetic

2E-QH4A

480V Isc 3P: 5995A Isc SLG:3746A

CBL-2E-ELEV P-1,S-2

(1) 4/0 AWG/kcmil 405 ft Magnetic

2E-BUS-0734

480V Isc 3P: 7012A Isc SLG:4456A

CBL-2E-ELEV P-2, P-3, S-1

(1) 350 AWG/kcmil 405 ft Magnetic

2E-BUS-0733

480V Isc 3P: 8498A Isc SLG:5593A

2E-QH1N-1

30A Frame 30A Trip

CBL-2E-TR-QL1N

(1) 10 AWG/kcmil 6 ft Magnetic

S

P 2E-TR-QL1N

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2E-QL1N

(1) 6 AWG/kcmil 6 ft Magnetic

2E-QL1N-MB

50A Frame 50A Trip

2E-QL1N

208V Isc 3P: 1396A Isc SLG:1398A

2E-QH1C-1

50A Frame 50A Trip

CBL-2E-TR-QLBC

(1) 6 AWG/kcmil 10 ft Magnetic

S

P 2E-TR-QLBC

30.0 kVA Pri. 480 V Sec. 208 V

7.80 %Z

CBL-2E-QLBC

(1) 2 AWG/kcmil 6 ft Magnetic

2E-QLBC-MB

100A Frame 100A Trip

2E-QLBC

208V Isc 3P: 973A Isc SLG:997A

2E-QMCC2-1

80A Frame 80A Trip 2E-AC-2 CBL-2E-QHPP 39.0 hp

(1) 4 AWG/kcmil 20 ft Magnetic

2E-QHPP

480V Isc 3P: 7724A Isc SLG:5129A

2E-QHPP-1

50A Frame 50A Trip

CBL-2E-TR-QLPP

(1) 6 AWG/kcmil 6 ft Magnetic

S

P 2E-TR-QLPP

30.0 kVA Pri. 480 V Sec. 208 V

7.80 %Z

CBL-2E-QLPP

(1) 2 AWG/kcmil 6 ft Magnetic

2E-QLPP-MB

90A Frame 90A Trip

2E-QLPP

208V Isc 3P: 1000A Isc SLG:1015A

2E-QLPP-1

40A Frame 40A Trip

CBL-2E-QLPP1

(1) 6 AWG/kcmil 75 ft Magnetic

2E-QLPP1

208V Isc 3P: 840A Isc SLG:748A

03-GEN-6

218.8 kVA 208 V

CBL-03-G6-MB

(2) 350 AWG/kcmil 20 ft Non-Magnetic

03-G6-MB

600A Frame 600A Trip

CBL-03-ATS-6-E

(2) 350 AWG/kcmil 20 ft Non-Magnetic

E N

03-ATS-6

CBL-03-ATS-6-DISC

(1) 500 AWG/kcmil 10 ft Non-Magnetic

03-DISC-ATS-6

400A Frame

FU-DISC-ATS-6

400A Frame 400A Trip

CBL-03-BPMCC

(1) 500 AWG/kcmil 10 ft Non-Magnetic

03-BPMCC

208V Isc 3P: 8505A Isc SLG:6363A

03-BPMCC-1

250A Frame 175A Trip

03-BPMCC-2

90A Frame 90A Trip

CBL-03-TR-6110-0183

(1) 2/0 AWG/kcmil 20 ft Magnetic

CBL-03-TR-6110-0261-1

(1) 2 AWG/kcmil 40 ft Magnetic

03-6110-0261-MB

03-6110-0261 240V Isc 3P: 727A Isc SLG:761A

S

P 03-TR-6110-0183

75.0 kVA Pri. 208 V Sec. 240 V

4.38 %Z

CBL-03-6110-0188

(1) 2 AWG/kcmil 20 ft Magnetic

CBL-03-DISC-6110-0183

(1) 2 AWG/kcmil 20 ft Magnetic

03-6110-0188-MB

03-6110-0188 240V Isc 3P: 2416A Isc SLG:2660A

03-DISC-6110-0183

400A Frame

FU-DISC-6110-0183

100A Frame 100A Trip

CBL-03-6110-0183

(1) 2 AWG/kcmil 30 ft Magnetic 03-6110-0183 240V Isc 3P: 2242A Isc SLG:2315A

11-GEN-09

625.0 kVA 208 V

BUS-0366

208V Isc 3P: 11551A Isc SLG:11551A

11-FP-01-MB

400A Frame 400A Trip 400A Plug

11-FP-03-MB

400A Frame 400A Trip 400A Plug

CBL-11-ATS-FP-01

(1) 350 AWG/kcmil 480 ft Magnetic

CBL-11-ATS-FP-03

(1) 350 AWG/kcmil 25 ft Magnetic

E N

11-ATS-FP-03

11-FP-03

75.0 hp

E N

01-ATS-FP-01

01-FP-01

75.0 hp

CBL-2E-L2EATS-N

(1) 2 AWG/kcmil 50 ft Magnetic

CBL-2E-CR2EATS-N

(2) 350 AWG/kcmil 75 ft Magnetic

CBL-2E-EQ2EATS-N

(3) 500 AWG/kcmil 75 ft Magnetic

2E-QMCC1-SCH

2E-QMCC2-SCH

2E-QHSW-1

30A Frame 30A Trip

CBL-2E-TR-QLSW

(1) 10 AWG/kcmil 10 ft Magnetic

S

P 2E-TR-QLSW

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2E-QLSW

(1) 8 AWG/kcmil 6 ft Magnetic

2E-QLSW-MB

60A Frame 60A Trip

2E-QLSW

208V Isc 3P: 1305A Isc SLG:1322A

CBL-01-ATS-FP-01-N

(1) 350 AWG/kcmil 240 ft Magnetic

CBL-11-ATS-FP-03-N

(1) 350 AWG/kcmil 230 ft Magnetic

2E-CH4A-1

100A Frame 100A Trip

CBL-2E-CH5A

(1) 2 AWG/kcmil 10 ft Magnetic

2E-CH5A

480V Isc 3P: 7931A Isc SLG:5668A

2E-CH1B-1

30A Frame 30A Trip

2E-CH1B-2

80A Frame 80A Trip

CBL-2E-TR-CL1B

(1) 10 AWG/kcmil 6 ft Magnetic

CBL-2E-TR-CHBB

(1) 4 AWG/kcmil 60 ft Magnetic

2E-CHBB

480V Isc 3P: 3661A Isc SLG:2264A

2E-CHBB-1

30A Frame 30A Trip

CBL-2E-TR-CLBB

(1) 10 AWG/kcmil 6 ft Magnetic

S

P 2E-TR-CLBB

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2E-CLBB

(1) 8 AWG/kcmil 6 ft Magnetic

2E-CLBB-MB

50A Frame 50A Trip

2E-CLBB

208V Isc 3P: 1260A Isc SLG:1290A

S

P 2E-TR-CL1B

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2E-CL1B

(1) 8 AWG/kcmil 6 ft Magnetic

2E-CL1B-MB

50A Frame 50A Trip

2E-CL1B

208V Isc 3P: 1293A Isc SLG:1313A

2E-CH1C-1

30A Frame 30A Trip

2E-CH1C-2

80A Frame 80A Trip

CBL-2E-TR-CL1C

(1) 10 AWG/kcmil 6 ft Magnetic

CBL-2E-CHBC

(1) 4 AWG/kcmil 10 ft Magnetic

2E-CHBC

480V Isc 3P: 3438A Isc SLG:2124A

S

P 2E-TR-CL1C

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2E-CL1C

(1) 6 AWG/kcmil 6 ft Magnetic

2E-CL1C-MB

60A Frame 60A Trip

2E-CL1C

208V Isc 3P: 1267A Isc SLG:1309A

2E-CHBC-1

30A Frame 30A Trip

CBL-2E-TR-CLBC

(1) 10 AWG/kcmil 6 ft Magnetic

S

P 2E-TR-CLBC

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2E-CLBC

(1) 8 AWG/kcmil 6 ft Magnetic

2E-CLBC-MB

50A Frame 50A Trip

2E-CLBC

208V Isc 3P: 1249A Isc SLG:1282A

2E-CH4C-1

100A Frame 100A Trip

CBL-2E-CH5C

(1) 2 AWG/kcmil 10 ft Magnetic

2E-CH5C

480V Isc 3P: 2947A Isc SLG:1806A

2E-CH3B-1

125A Frame 125A Trip

CBL-2E-TR-CL3B

(1) 1 AWG/kcmil 6 ft Magnetic

S

P 2E-TR-CL3B

75.0 kVA Pri. 480 V Sec. 208 V

5.10 %Z

CBL-2E-CL3B

(1) 250 AWG/kcmil 6 ft Magnetic

2E-CL3B-MB

225A Frame 225A Trip

2E-CL3B

208V Isc 3P: 3196A Isc SLG:3414A

03-6110-0310 208V Isc 3P: 5511A Isc SLG:3760A

03-6110-0310-MB

100A Frame 100A Trip

CBL-03-6110-0310

(1) 2 AWG/kcmil 45 ft Magnetic

03-BPMCC-3

100A Frame 100A Trip

CBL-03-ATS-6-N-2

(1) 500 AWG/kcmil 50 ft Non-Magnetic

S

P 03-TR-6110-0261

15.0 kVA Pri. 208 V Sec. 240 V

4.20 %Z

03-SW-TR-6110-0261

CBL-03-TR-6110-0261-2

(1) 2 AWG/kcmil 10 ft Magnetic

CBL-03-6110-0261

(1) 2 AWG/kcmil 10 ft Magnetic

2W-GEN-10

343.8 kVA 480 V

CBL-2W-GEN10-MB

(1) 500 AWG/kcmil 20 ft Magnetic

2W-GEN10-MB

400A Frame 400A Trip 400A Plug

CBL-2W-EDP2W

(2) 3/0 AWG/kcmil 10 ft Magnetic

2W-EDP2W

480V Isc 3P: 2719A Isc SLG:2703A

2W-EDP2W-2

200A Frame 200A Trip

2W-EDP2W-3

100A Frame 100A Trip

2W-EDP2W-4

80A Frame 80A Trip

2W-EDP2W-1

300A Frame 300A Trip

CBL-2W-ATS-QMCC-E

(1) 3/0 AWG/kcmil 6 ft Magnetic

CBL-2W-ATS-EQ-E

(1) 2 AWG/kcmil 80 ft Magnetic

CBL-2W-ATS-LS-E

(1) 4 AWG/kcmil 90 ft Magnetic

CBL-2C-EDP2C

(1) 350 AWG/kcmil 160 ft Magnetic

2C-EDP2C

480V Isc 3P: 2514A Isc SLG:2404A

2C-EDP2C-1

250A Frame 250A Trip

2C-EDP2C-2

100A Frame 100A Trip

2C-EDP2C-3

80A Frame 80A Trip

CBL-2C-ATS-EQDP2C-E

(1) 4/0 AWG/kcmil 10 ft Magnetic

CBL-2C-ATS-CRDP2C-E

(1) 2 AWG/kcmil 15 ft Magnetic

CBL-2C-ATS-LSDP2C-E

(1) 2 AWG/kcmil 15 ft Magnetic

E N

2C-ATS-CR

E N

2C-ATS-LS

CBL-2C-CRDP2C

(1) 2 AWG/kcmil 6 ft Magnetic

2C-CRDP2C

480V Isc 3P: 9203A Isc SLG:8416A

CBL-2C-LSDP2C

(1) 2 AWG/kcmil 6 ft Magnetic

2C-LSDP2C

480V Isc 3P: 9203A Isc SLG:8416A

E N

2C-ATS-EQ

CBL-2C-EQDP2C

(1) 4/0 AWG/kcmil 6 ft Magnetic

2C-EQDP2C-MB

225A Frame 225A Trip

2C-EQDP2C

480V Isc 3P: 9423A Isc SLG:8747A

2C-EQDP2C-2

15A Frame 15A Trip

2C-EQDP2C-3

90A Frame 90A Trip

2C-EQDP2C-4

150A Frame 150A Trip

2C-EQDP2C-5

60A Frame 60A Trip

2C-EQDP2C-1

15A Frame 15A Trip

CBL-2C-TR-QL1F

(1) 8 AWG/kcmil 60 ft Magnetic

CBL-2C-ELEV P6-1

(1) 2 AWG/kcmil 60 ft Magnetic

CBL-2C-ELEV P7-1

(1) 6 AWG/kcmil 190 ft Magnetic

CBL-2C-QHPA

(1) 2 AWG/kcmil 110 ft Magnetic

2C-QHPA

480V Isc 3P: 6014A Isc SLG:4433A

CBL-2C-TR-QLBB

(1) 10 AWG/kcmil 190 ft Magnetic

2C-QHBA-1

50A Frame 50A Trip

CBL-2C-TR-QLPA

(1) 6 AWG/kcmil 6 ft Magnetic

S

P 2C-TR-QLPA

45.0 kVA Pri. 480 V Sec. 208 V

7.80 %Z

CBL-2C-QLPA

(1) 2 AWG/kcmil 10 ft Magnetic

2C-QLPA-MB

100A Frame 100A Trip

2C-QLPA

208V Isc 3P: 1417A Isc SLG:1451A

2C-ELEV P7-MB

60A Frame 60A Trip

CBL-2C-ELEV P7-2

(1) 4 AWG/kcmil 10 ft Magnetic

ELEV P7

50.0 hp

2C-ELEV P6-MB

60A Frame 60A Trip

CBL-2C-ELEV P6-2

(1) 4 AWG/kcmil 10 ft Magnetic

ELEV P6

40.0 hp

S

P 2C-TR-QL1F

9.0 kVA Pri. 480 V Sec. 208 V

2.96 %Z

CBL-2C-QL1F

(1) 10 AWG/kcmil 10 ft Magnetic

2C-QL1F-MB

30A Frame 30A Trip

2C-QL1F

208V Isc 3P: 757A Isc SLG:752A

S

P 2C-TR-QLBB

9.0 kVA Pri. 480 V Sec. 208 V

2.96 %Z

CBL-2C-QLBB

(1) 10 AWG/kcmil 10 ft Magnetic

2C-QLBB-MB

30A Frame 30A Trip

2C-QLBB

208V Isc 3P: 671A Isc SLG:692A

2C-CRDP2C-1

60A Frame 60A Trip

2C-CRDP2C-2

80A Frame 80A Trip

CBL-2C-CH1F

(1) 6 AWG/kcmil 60 ft Magnetic

2C-CH1F

480V Isc 3P: 5292A Isc SLG:3654A

CBL-2C-CH2F

(1) 4 AWG/kcmil 75 ft Magnetic

2C-CH2F

480V Isc 3P: 5794A Isc SLG:4156A

2C-CH1F-1

50A Frame 50A Trip

CBL-2C-TR-CL1F

(1) 6 AWG/kcmil 15 ft Magnetic

2C-CH2F-2

60A Frame 60A Trip

2C-CH2F-1

50A Frame 50A Trip

CBL-2C-CH3F

(1) 6 AWG/kcmil 35 ft Magnetic

2C-CH3F

480V Isc 3P: 4377A Isc SLG:2910A

CBL-2C-TR-CL2F

(1) 6 AWG/kcmil 15 ft Magnetic

2C-CH3F-1

30A Frame 30A Trip

CBL-2C-TR-CL3F

(1) 10 AWG/kcmil 6 ft Magnetic

S

P 2C-TR-CL3F

15.0 kVA Pri. 480 V Sec. 208 V

2.80 %Z

CBL-2C-CL3F

(1) 8 AWG/kcmil 6 ft Magnetic

2C-CL3F-MB

60A Frame 60A Trip

2C-CL3F

208V Isc 3P: 1279A Isc SLG:1306A

S

P 2C-TR-CL2F

30.0 kVA Pri. 480 V Sec. 208 V

7.80 %Z

CBL-2C-CL2F

(1) 2 AWG/kcmil 15 ft Magnetic

2C-CL2F-MB

100A Frame 100A Trip

2C-CL2F

208V Isc 3P: 974A Isc SLG:988A

2C-CL2F-1

40A Frame 40A Trip

CBL-2C-CL2F1

(1) 2 AWG/kcmil 25 ft Magnetic

2C-CL2F1

208V Isc 3P: 947A Isc SLG:944A

2C-LSDP2C-1

40A Frame 40A Trip

2C-LSDP2C-2

60A Frame 60A Trip

2C-EH2F-1

20A Frame 20A Trip

CBL-2C-EH1F

(1) 2 AWG/kcmil 60 ft Magnetic

2C-EH1F

480V Isc 3P: 7105A Isc SLG:5598A

CBL-2C-EH2F

(1) 6 AWG/kcmil 80 ft Magnetic

2C-EH2F

480V Isc 3P: 4509A Isc SLG:2997A

CBL-2C-EH3F

(1) 8 AWG/kcmil 100 ft Magnetic

2C-EH3F

480V Isc 3P: 1997A Isc SLG:1210A

2C-EH1F-1

100A Frame 100A Trip

2C-LSDP2C-3

15A Frame 15A Trip

CBL-2C-TR-ELBB

(1) 6 AWG/kcmil 190 ft Magnetic

CBL-2C-TR-EL1F

(1) 12 AWG/kcmil 50 ft Magnetic

S

P 2C-TR-ELBB

9.0 kVA Pri. 480 V Sec. 208 V

2.96 %Z

CBL-2C-ELBB

(1) 10 AWG/kcmil 10 ft Magnetic

2C-ELBB-MB

30A Frame 30A Trip

2C-ELBB

208V Isc 3P: 720A Isc SLG:727A

S

P 2C-TR-EL1F

9.0 kVA Pri. 480 V Sec. 208 V

2.96 %Z

CBL-2C-EL1F

(1) 10 AWG/kcmil 6 ft Magnetic

2C-EL1F-MB

30A Frame 30A Trip

2C-EL1F

208V Isc 3P: 748A Isc SLG:759A

E N

2W-ATS-QMCC

CBL-2W-QMCC

(1) 3/0 AWG/kcmil 120 ft Magnetic

2W-QMCCW

480V Isc 3P: 12441A Isc SLG:8390A

E N

2W-ATS-EQ

CBL-2W-QHBM

(1) 2 AWG/kcmil 40 ft Magnetic

2W-QHBM-MB

100A Frame 100A Trip

2W-QHBM

480V Isc 3P: 10071A Isc SLG:6345A

2W-QHBM-1

50A Frame 50A Trip

CBL-2W-TR-QLBM

(1) 6 AWG/kcmil 10 ft Magnetic

S

P 2W-TR-QLBM

30.0 kVA Pri. 480 V Sec. 208 V

7.80 %Z

CBL-2W-QLBM

(1) 2 AWG/kcmil 10 ft Magnetic

2W-QLBM-MB

100A Frame 100A Trip

2W-QLBM

208V Isc 3P: 1015A Isc SLG:1021A

E N

2W-ATS-LS

CBL-2W-ATS-LS

(1) 4 AWG/kcmil 90 ft Magnetic

2W-EHBM-MB

80A Frame 80A Trip

2W-EHBM

480V Isc 3P: 4702A Isc SLG:2815A

2W-EHBM-1

15A Frame 15A Trip

CBL-2W-TR-ELBM

(1) 12 AWG/kcmil 10 ft Magnetic

S

P 2W-TR-ELBM

9.0 kVA Pri. 480 V Sec. 208 V

2.96 %Z

CBL-2W-ELBM

(1) 8 AWG/kcmil 10 ft Magnetic

2W-ELBM-MB

50A Frame 50A Trip

2W-ELBM

208V Isc 3P: 769A Isc SLG:770A

CBL-2W-ATS-LS-N

(1) 4 AWG/kcmil 80 ft Magnetic

CBL-2W-ATS-EQ-N

(1) 2 AWG/kcmil 70 ft Magnetic

CBL-2W-ATS-QMCC-N

(1) 3/0 AWG/kcmil 50 ft Magnetic

CBL-2C-ATS-LSDP2C-N

(1) 2 AWG/kcmil 15 ft Magnetic

CBL-2C-ATS-CRDP2C-N

(1) 2 AWG/kcmil 15 ft Magnetic

CBL-2C-ATS-EQDP2C-N

(1) 4/0 AWG/kcmil 25 ft Magnetic

2W-QMCCW-SCH

2C-QLPA-1

80A Frame 80A Trip

CBL-2C-6110-0442

(1) 6 AWG/kcmil 75 ft Magnetic 2C-6110-0442 208V Isc 3P: 1093A Isc SLG:927A

2C-LSDP2C-MB

100A Frame 100A Trip

S

P 2C-TR-CL1F

30.0 kVA Pri. 480 V Sec. 208 V

7.80 %Z

CBL-2C-CL1F

(1) 2 AWG/kcmil 10 ft Magnetic

2C-CL1F-MB

100A Frame 100A Trip

2C-CL1F

208V Isc 3P: 976A Isc SLG:995A

CBL-2C-CH1D

(1) 6 AWG/kcmil 160 ft Magnetic

2C-CH1D

480V Isc 3P: 3070A Isc SLG:1853A

BUS-0834

208V Isc 3P: 4429A Isc SLG:3175A

BUS-0833

208V Isc 3P: 7271A Isc SLG:4281A

REFER TO 02E-603REFER TO 02E-603

E N

L

BREAKER

600A

3P ADJUSTABLE

REFER TO 02E-603

FROM CBL-2E-EQ2EATS-N

REFER TO 02E-603

(NEW)

400AF

225AT

3P

UPS-A

480V 225A

REFER TO UPS ONE LINE

#250 MCM

125A

SPD

3P

CRAC-02

480V 125A

(NEW)

400AF

225AT

3P

UPS-B

480V 225A

REFER TO UPS ONE LINE

#250 MCM

(NEW)

175A 3P

150KVA T-2E-TR-B

480V-120/208V, 3PH, 4W

400A 3P

B2E-EP-TR

MCR-EP

60A

#2/0 CU

B2E-TR2E-1178B

60A

B2E-TR2E-4155B

60A

B2E-TR2E-4115BB

60A

B2E-TR2E-2149B

60A

B2E-TR2E-3113BB

60A

B2E-TR2E-B127AB

60A

125A

SPD

3P

CRAC-01

480V 125A

2E-EDP2E-MCR

600AF

600ATATS-MCR-A

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:2

02E-604

ELECTRICAL ONE-LINE DIAGRAMS 689A4-22-700

01_02

07/03/2024 M. Perkins J. Schooley

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

KEYNOTES:

1.

2.

3.

4.

5.

PROVIDE NEW ATS

PROVIDE NEW UPS TO SERVE MAIN COMPUTER ROOM

EQUIPMENTS

PROVIDE NEW PANEL BOARD TO SERVE TR'S ROOMS

PROVIDE NEW CRAC TO SERVE NEW MAIN COMPUTER ROOM

PROVIDE NEW MAIN DISTRUBTION PANEL BOARD

Revisions: Date:

125A 3P

112.5KVA T-2C-TR-B

480V-120/208V, 3PH, 4W

225A 3P

B2C-EP-TR

B2C-TR2C-3140B

60A

B2C-TR2C-1155B

60A

B2C-TR2C-2138DB

60A

B2W-TR2W-121B

100A

(NEW)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:2

02E-605

ELECTRICAL ONE-LINE DIAGRAMS 689A4-22-700

01_02

07/03/2024 M. Perkins J. Schooley

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

B2E-NP-TR

B2E-TR2E-2149A

60A

(NEW)

125A 3P

75KVA T-2E-TR-A

480V-120/208V, 3PH, 4W

225A 3P

B2E-TR2E-4155A

60A

B2E-TR2E-4115BA

60A

B2E-TR2E-B127AA

60A

B2E-TR2E-3113AA

60A

B2E-TR2E-1178A

60A

FEEDER & BRANCH CIRCUIT SIZING SCHEDULE -

GENERAL PURPOSE

2/0 6 1 1/2" 2" 2"

1 1/2"

2 1/2"

2-2 1/2"

3-2 1/2"

4-2 1/2"

5-2 1/2"

6-2 1/2"

2-500

2-600

3-400

4-350

5-400

6-400

5-4/0

6-250

2-1/0

2-1/0

3-2/0

4-3/0

2-3"

2-3"

3/0

4/0

2-4/0

2-250

2-350

3"3

2-2

2-2

2-1

3 3"

2-2"

2-2"

2"

2"

6-3"

3-3"

4-3"

5-3"

2-3"

2-3"

6-3"

2-3 1/2"

3-3"

4-3"

5-3"

2-4"

3"

2-2 1/2"

4"

2-2"

2-3"

2 1/2"

3"

2"

2"

3 1/2"

2-2 1/2"

2-3"

4"

2-2 1/2"

2 1/2"

3"

2"

2 1/2"

3/4"(1")

3/4"(1")

3/4"

3/4"

3/4"

3/4"

1"(1 1/4")

1 1/4"

1 1/4"

1 1/4"

2 WIRE

8(6)

6(4)

6(4)

4(2)

3(2)

2(1)

1/0

1(1/0)

8 1"

PHASE

& NEUTRAL

WIRE SIZE - AWG OR KCMIL

E.G.

3/4" 3/4"

1 1/4"(1 1/2")1 1/4"(1 1/2")

1 1/2"

1 1/2"

1 1/4"

3/4"(1")

3/4"(1")

3/4"

1"(1 1/4")

2"

1 1/2"(2")

1 1/4"

1"(1 1/4")

1"(1 1/4")

1 1/4"

3/4"(1")

CONDUIT SIZE

3/4"

3/4"

3 WIRE

3/4"

3/4"

4 WIRE

(3PH & 1N) NOTE

1.

2.

3.

4.

CIRCUIT MAXIMUM DISTANCE IS BASED ON

NEC CHAPTER 9, TABLE 8 CONDUCTOR

PROPERTIES FOR COATED COPPER

CONDUCTORS AT 75 DEGREES CELSIUS.

MAXIMUM CIRCUIT LOAD FOR DISTANCE IS

BASED ON NEC 220-10(b)

BASED ON THHN/THWN, 90°., 600V.,

INSULATED, COPPER WIRE APPLIED AT 75°FOR

TERMINATIONS RATED AT 60°C/75°C AND 75°C.

FOR TERMINATIONS RATED AT 60°C PROVIDE

WIRE AND CONDUIT SIZES INDICATED IN

PARENTHESIS.

BASED ON WIRE OUTSIDE DIAMETERS AND

RIGID METALLIC CONDUIT INSIDE DIAMETERS

AS PROVIDED IN THE NEC. DO NOT REDUCE

CONDUIT SIZE FOR NON-RIGID METALLIC

APPLICATION. REFER TO NEC FOR CONDUIT

TYPES MORE RESTRICTIVE THAN RIGID

METALLIC.

NOTES:

(NOTES 1 & 2)

120V. SINGLE PHASE CIRCUIT LENGTH TABLE 208V. THREE PHASE CIRCUIT LENGTH TABLE

LOAD

(VOLT-AMPS)

MAX.

CIRCUIT

17280

14400

11520

(AMPS)

AMPACITY

BREAKER

CURRENT

(AMPS)

MAX.

CIRCUIT

NO.8

MAXIMUM LENGTH IN FEET

- 58

110 174

NO.12

NO.10

73 116

117-

NO.4

NO.6

(AMPS)

BREAKER

AMPACITY

LOAD

(VOLT-AMPS)

CIRCUIT

MAX.

CURRENT

(AMPS)

CIRCUIT

MAX.

234-- --

116-

NO.10

NO.12

233127

294 468

177 281

221 351139

NO.6

NO.4

NO.8

MAXIMUM LENGTH IN FEET

35-40

45-50

80-90

15-20

25-30

OVERCURRENT

DEVICE RATING

(AMPERES)

07/03/2024

07/03/2024

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:3

01E-701

ELECTRICAL SCHEDULES B01 689A4-22-700

01_02

07/03/2024 M. Perkins J. Schooley

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

1.

2.

3.

4.

PROVIDE A 30 DAY LOAD MEASUREMENT OF PANELBOARD

INDICATED. PROVIDE THE REPORT TO THE COR AND AE PRIOR TO

COMMENCEMENT OF PANELBOARD RENOVATION. PANEL DEMAND

IS CALCULATED BY LOADING EACH CIRCUIT BREAKER TO 80%

CAPACITY.

NEW ELECTRICAL PANEL AND CIRCUIT BREAKERS SIZED AS

INDICATED, SEE E-100 SERIES FOR PANEL LOCATION.

RELOCATED EXISTING ELECTRICAL PANEL, CIRCUIT BREAKER AND

FEEDER. CIRCUITS TO BE REPULLED AND TERMINATED.SEE E-600

ONLINE NOTES FOR ADDITIONAL INFORMATION.

PANEL MAINS TO BE 100% RATED BREAKERS

KEYNOTES

NOTE: NOT ALL KEYNOTES ARE USED ON EACH SHEET

LUMINAIRE SCHEDULE

TYPE DESCRIPTION MOUNTING VOLTS LAMPS DRIVER LOAD MANUFACTURER AND MODEL NO.

L1 4'0" LINEAR, WRAP AROUND ACRYLIC LENS, LED STRIP,

PENDANT 6” ABOVE CABLETRAY WITH PENDANT MOUNTING

KIT

PENDANT

9'0" AFF

MVOLT 3500k

85CRI

0-10V

DIMMABLE

42 VA COLUMBIA #LCL SERIES OR APPROVED EQUAL

L1B 4'0" LINEAR (BATTERY BACKED), WRAP AROUND ACRYLIC

LENS, LED STRIP, PENDANT 6” ABOVE CABLE TRAY WITH

PENDANT MOUNTING KIT

PENDANT

9'0" AFF

MVOLT 3500k

85CRI

42 VA COLUMBIA #LCL SERIES OR APPROVED EQUAL

L2 24"X24" SQUARE LUMINAIRE RECESSED

MV

MVOLTS LED 0-10V

DIMMABLE

17 VA TRAYFIT AXIS LIGHTING

L3 2X2 RECESSED, 600 LUMENS, 82 CRI RECESSED MVOLTS LED 120 47 VA 2BLT2 60L 120V EZ1 LP835

1. INSTALL BUS EXTENDER KIT PER MANUFACTURER'S RECOMMENDATIONS FOR TWO NEW 3-POLE PANELBOARD SPACES.

2. PANEL SPACE NUMBERING 25-30 ARE THE EXISTING LARGE BREAKERS. VERIFY CAPACITY FOR THE NEW EP-TR AND HVAC BI BREAKERS.

3. ADD SPD DEVICES INTEGRAL TO ALL NEW TELECOM PANELBOARDS (SQ D OR EQUAL) FOR TYPE 2 PROTECTION.

4. ADD PXR 20 TRIP UNITS FOR ADJUSTING CIRCUIT BREAKERS (EATON OR EQUAL).

Notes:

Total Est. Demand: 98 A ACCESS CONTROLLER 415 VA 100.00% 415 VA Total Conn.: 98 A LTG 840 VA 125.00% 1050 VA Total Est. Demand: 35329 VA NC 12635 VA 100.00% 12635 VA Total Conn. Load: 35129 VA Receptacle 21280 VA 100.00% 21280 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 92 A 105 A 97 A Total Load: 11022 VA 12582 VA 11525 VA

41 SPD 60 A 1 0 VA -- 1 -- SPACE 42

39 SPD 60 A 1 0 VA -- 1 -- SPACE 40

37 SPD 60 A 1 0 VA -- 1 -- SPACE 38

35 SPACE -- 1 -- -- 1 -- SPACE 36

33 SPACE -- 1 -- -- 1 -- SPACE 34

31 SPACE -- 1 -- -- 1 -- SPACE 32

29 1152... -- 1 -- SPACE 30

27 1258... -- 1 -- SPACE 28

B01-EP-TR 150 A 3

1102... -- 1 -- SPACE 26

23 0 VA 0 VA 24

21 0 VA 0 VA 22

1ST FLR EMERGENCY PANEL - 6110-0304 100 A 3

0 VA 0 VA

3 50 A EXISTING CIRCUIT

17 0 VA 0 VA 18

15 0 VA 0 VA 16

EXISTING CIRCUIT 60 A 3

0 VA 0 VA

3 50 A EXISTING CIRCUIT

11 0 VA 0 VA 1 20 A MECH ROOM 12

9 0 VA 0 VA 1 20 A MECH ROOM 10

MECH ROOM COMP 20 A 3

0 VA 0 VA 1 20 A SPARE 8

5 MECH ROOM 20 A 1 0 VA 0 VA 6

3 MECH ROOM 20 A 1 0 VA 0 VA 4

1 SPARE 20 A 1 0 VA 0 VA

3 100 A EXISTING CIRCUIT

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Enclosure: Indoor MCB Rating: 600 A Mounting: Surface Wires: 4 Mains Rating: 800 A

Supply From: Phases: 3 Mains Type: MCB Location: ELECT. 1S-162-0 Volts: 208Y/120 A.I.C. Rating: VIF

Branch Panel: 6110-0386

1. ADD SPD DEVICES INTEGRAL TO ALL NEW TELECOM PANELBOARDS (SQ D OR EQUAL) FOR TYPE 2 PROTECTION.

2. ADD PXR 20 TRIP UNITS FOR ADJUSTING CIRCUIT BREAKERS (EATON OR EQUAL).

Notes:

Total Est. Demand: 76 A Total Conn.: 76 A

Total Est. Demand: 27487 VA Lighting 987 VA 100.00% 987 VA Total Conn. Load: 27487 VA Receptacle 26500 VA 100.00% 26500 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 95 A 84 A 58 A Total Load: 10960 VA 9613 VA 6913 VA

41 SPD 20 A 1 0 VA -- 1 -- SPACE 42

39 SPD 20 A 1 0 VA -- 1 -- SPACE 40

37 SPD 20 A 1 0 VA -- 1 -- SPACE 38

35 SPACE -- 1 -- -- 1 -- SPACE 36

33 SPACE -- 1 -- -- 1 -- SPACE 34

31 SPACE -- 1 -- -- 1 -- SPACE 32

29 SPACE -- 1 -- -- 1 -- SPACE 30

27 SPACE -- 1 -- -- 1 -- SPACE 28

25 SPACE -- 1 -- -- 1 -- SPACE 26

23 SPARE 20 A 1 0 VA -- 1 -- SPACE 24

21 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 22

19 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 20

17 1167... 0 VA 1 20 A SPARE 18

15 2247... 0 VA 1 20 A SPARE 16

B01-TR1C-142A 60 A 3

1887... 0 VA 1 20 A SPARE 14

11 1167... 1167... 12 9 1167... 1887... 10

B01-TR1C-242A 60 A 3

1887... 1347...

3 60 A B01-TR1-324A

5 2247... 1167... 6 3 3147... 1167... 4

B01-TR1-424A 60 A 3

3954... 1887...

3 60 A B01-TR1-524A

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Enclosure: Indoor MCB Rating: 150 A Mounting: Surface Wires: 4 Mains Rating: 150 A

Supply From: Phases: 3 Mains Type: MCB Location: TELECOM ROOM 1C-142 Volts: 208Y/120 A.I.C. Rating: 22kA

Branch Panel: B01-NP-TR

1. ADD SPD DEVICES INTEGRAL TO ALL NEW TELECOM PANELBOARDS (SQ D OR EQUAL) FOR TYPE 2 PROTECTION.

2. ADD PXR 20 TRIP UNITS FOR ADJUSTING CIRCUIT BREAKERS (EATON OR EQUAL).

Notes:

Total Est. Demand: 98 A ACCESS CONTROLLER 415 VA 100.00% 415 VA Total Conn.: 98 A LTG 840 VA 125.00% 1050 VA Total Est. Demand: 35329 VA NC 12635 VA 100.00% 12635 VA Total Conn. Load: 35129 VA Receptacle 21280 VA 100.00% 21280 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 92 A 105 A 97 A Total Load: 11022 VA 12582 VA 11525 VA

41 SPD 20 A 1 0 VA -- 1 -- SPACE 42

39 SPD 20 A 1 0 VA -- 1 -- SPACE 40

37 SPD 20 A 1 0 VA -- 1 -- SPACE 38

35 SPACE -- 1 -- -- 1 -- SPACE 36

33 SPACE -- 1 -- -- 1 -- SPACE 34

31 SPACE -- 1 -- -- 1 -- SPACE 32

29 SPACE -- 1 -- -- 1 -- SPACE 30

27 SPACE -- 1 -- -- 1 -- SPACE 28

25 SPACE -- 1 -- -- 1 -- SPACE 26

23 SPARE 20 A 1 0 VA -- 1 -- SPACE 24

21 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 22

19 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 20

17 5172... 0 VA 1 20 A SPARE 18

15 6030... 0 VA 1 20 A SPARE 16

B01-TR1C-142B 100 A 3

5415... 0 VA 1 20 A SPARE 14

11 1209... 1372... 12 9 1887... 1929... 10

B01-TR1C-242B 60 A 3

1452... 1573...

3 60 A B01-TR1-324B

5 1887... 1887... 6 3 1369... 1369... 4

B01-TR1-424B 60 A 3

1292... 1292...

3 60 A B01-TR1-524B

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Enclosure: Indoor MCB Rating: 150 A Mounting: Surface Wires: 4 Mains Rating: 225 A

Supply From: 6110-0386 Phases: 3 Mains Type: MCB Location: TELECOM ROOM 1C-142 Volts: 208Y/120 A.I.C. Rating: 22kA

Branch Panel: B01-EP-TR

NOT TO SCALE

E1 6110-0386 DISTRIBUTION BOARD

ATS-7-2

01-ATS-7-2-LD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

CONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202

MAT PERKINS

(315) 484-5958

STAMP

Au to de sk

D oc s:

//6

A4

-2 2-

0_

N ew in gt on _V

AM

C

_E H

R M

_I U

-1

2/

9A 4-

-7

.N ew in gt on

.E H

R M

.M

EP

.B

_0 2_

R

.rv t

-1

0-

6:

:3

01E-702

ELECTRICAL SCHEDULES B01 689A4-22-700

01_02

07/03/2024 M. Perkins J. Schooley

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

555 Willard Avenue, Newington, CT 06111

1.

2.

3.

4.

PROVIDE A 30 DAY LOAD MEASUREMENT OF PANELBOARD

INDICATED. PROVIDE THE REPORT TO THE COR AND AE PRIOR TO

COMMENCEMENT OF PANELBOARD RENOVATION. PANEL DEMAND

IS CALCULATED BY LOADING EACH CIRCUIT BREAKER TO 80%

CAPACITY.

NEW ELECTRICAL PANEL AND CIRCUIT BREAKERS SIZED AS

INDICATED, SEE E-100 SERIES FOR PANEL LOCATION.

RELOCATED EXISTING ELECTRICAL PANEL, CIRCUIT BREAKER AND

FEEDER. CIRCUITS TO BE REPULLED AND TERMINATED.SEE E-600

ONLINE NOTES FOR ADDITIONAL INFORMATION.

PANEL MAINS TO BE 100% RATED BREAKERS

KEYNOTES

NOTE: NOT ALL KEYNOTES ARE USED ON EACH SHEET

1. ADD SPD DEVICES INTEGRAL TO ALL NEW TELECOM PANELBOARDS (SQ D OR EQUAL) FOR TYPE 2 PROTECTION.

2. ADD PXR 20 TRIP UNITS FOR ADJUSTING CIRCUIT BREAKERS (EATON OR EQUAL).

Notes:

Total Est. Demand: 15 A Total Conn.: 15 A

Total Est. Demand: 5300 VA Total Conn. Load: 5300 VA

Receptacle 5300 VA 100.00% 5300 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 17 A 20 A 10 A Total Load: 1887 VA 2247 VA 1167 VA

29 SPD 20 A 1 0 VA -- 1 -- SPACE 30

27 SPD 20 A 1 0 VA -- 1 -- SPACE 28

25 SPD 20 A 1 0 VA -- 1 -- SPACE 26

23 SPACE -- 1 -- -- 1 -- SPACE 24

21 SPACE -- 1 -- -- 1 -- SPACE 22

19 SPACE -- 1 -- -- 1 -- SPACE 20

17 SPACE -- 1 -- -- 1 -- SPACE 18

15 SPACE -- 1 -- -- 1 -- SPACE 16

13 SPACE -- 1 -- -- 1 -- SPACE 14

11 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 12

9 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 10

7 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 8

5 SPARE 20 A 1 0 VA 1167... 6

3 MCR RECEPTACLE 20 A 1 1080... 1167... 4

1 TR #1C-143 RECEPTACLE 20 A 1 720 VA 1167...

3 20 A TR #1C-143 RACK RECEPTACLE

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Enclosure: Indoor MCB Rating: 60 A Mounting: Surface Wires: 4 Mains Rating: 125 A

Supply From: B01-NP-TR Phases: 3 Mains Type: MCB Location: TELECOM ROOM 1C-142 Volts: 208Y/120 A.I.C. Rating: 10kA

Branch Panel: B01-TR1C-142A

1. ADD SPD DEVICES INTEGRAL TO ALL NEW TELECOM PANELBOARDS (SQ D OR EQUAL) FOR TYPE 2 PROTECTION.

2. ADD PXR 20 TRIP UNITS FOR ADJUSTING CIRCUIT BREAKERS (EATON OR EQUAL).

Notes:

Total Est. Demand: 46 A ACCESS CONTROLLER 83 VA 100.00% 83 VA Total Conn.: 46 A LTG 168 VA 125.00% 210 VA Total Est. Demand: 16656 VA NC 11973 VA 100.00% 11973 VA Total Conn. Load: 16616 VA Receptacle 4400 VA 100.00% 4400 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 45 A 51 A 43 A Total Load: 5415 VA 6030 VA 5172 VA

29 SPD 20 A 1 0 VA -- 1 -- SPACE 30

27 SPD 20 A 1 0 VA -- 1 -- SPACE 28

25 SPD 20 A 1 0 VA -- 1 -- SPACE 26

23 SPACE -- 1 -- -- 1 -- SPACE 24

21 SPACE -- 1 -- -- 1 -- SPACE 22

19 SPACE -- 1 -- -- 1 -- SPACE 20

17 SPARE 20 A 1 0 VA -- 1 -- SPACE 18

15 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 16

13 3963... 0 VA 1 20 A SPARE 14

11 3963... 0 VA 1 20 A SPARE 12

VFD-CU-01 50 A 3

3963... 1167... 10

7 42 VA 1167... 8

IU-1-01 15 A 2

42 VA 1167...

3 20 A TR #1C-142 RACK RECEPTACLE

3 TR #1C-143 20 A 1 720 VA 180 VA 1 20 A CU-01 VRF UNIT RECEPTACLE 4

1 TR #1C-142 ACCESS CONTROLLER 20 A 1 83 VA 168 VA 1 20 A TR #1C-143 LIGHTING 2

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Enclosure: Indoor MCB Rating: 100 A Mounting: Surface Wires: 4 Mains Rating: 125 A

Supply From: B01-EP-TR Phases: 3 Mains Type: MCB Location: TELECOM ROOM 1C-142 Volts: 208Y/120 A.I.C. Rating: 10kA

Branch Panel: B01-TR1C-142B

1. ADD SPD DEVICES INTEGRAL TO ALL NEW TELECOM PANELBOARDS (SQ D OR EQUAL) FOR TYPE 2 PROTECTION.

2. ADD PXR 20 TRIP UNITS FOR ADJUSTING CIRCUIT BREAKERS (EATON OR EQUAL).

Notes:

Total Est. Demand: 12 A Total Conn.: 12 A

Total Est. Demand: 4220 VA Total Conn. Load: 4220 VA

Receptacle 4220 VA 100.00% 4220 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 16 A 10 A 10 A Total Load: 1887 VA 1167 VA 1167 VA

29 SPD 20 A 1 0 VA -- 1 -- SPACE 30

27 SPD 20 A 1 0 VA -- 1 -- SPACE 28

25 SPD 20 A 1 0 VA -- 1 -- SPACE 26

23 SPACE -- 1 -- -- 1 -- SPACE 24

21 SPACE -- 1 -- -- 1 -- SPACE 22

19 SPACE -- 1 -- -- 1 -- SPACE 20

17 SPACE -- 1 -- -- 1 -- SPACE 18

15 SPACE -- 1 -- -- 1 -- SPACE 16

13 SPACE -- 1 -- -- 1 -- SPACE 14

11 SPACE -- 1 -- 0 VA 1 20 A SPARE 12

9 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 10

7 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 8

5 SPARE 20 A 1 0 VA 1167... 6

3 SPARE 20 A 1 0 VA 1167... 4

1 TR #1C-242 RECEPTACLE 20 A 1 720 VA 1167...

3 20 A TR #1C-242 RACK RECEPTACLE

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Enclosure: Indoor MCB Rating: 60 A Mounting: Surface Wires: 4 Mains Rating: 125 A

Supply From: B01-NP-TR Phases: 3 Mains Type: MCB Location: TELECOM ROOM 1C-242 Volts: 208Y/120 A.I.C. Rating: 10kA

Branch Panel: B01-TR1C-242A

1. ADD SPD DEVICES INTEGRAL TO ALL NEW TELECOM PANELBOARDS (SQ D OR EQUAL) FOR TYPE 2 PROTECTION.

2. ADD PXR 20 TRIP UNITS FOR ADJUSTING CIRCUIT BREAKERS (EATON OR EQUAL).

Notes:

Total Est. Demand: 13 A ACCESS CONTROLLER 83 VA 100.00% 83 VA Total Conn.: 13 A LTG 168 VA 125.00% 210 VA Total Est. Demand: 4587 VA NC 84 VA 100.00% 84 VA Total Conn. Load: 4547 VA Receptacle 4220 VA 100.00% 4220 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 12 A 16 A 10 A Total Load: 1452 VA 1887 VA 1209 VA

29 SPD 20 A 1 0 VA -- 1 -- SPACE 30

27 SPD 20 A 1 0 VA -- 1 -- SPACE 28

25 SPD 20 A 1 0 VA -- 1 -- SPACE 26

23 SPACE -- 1 -- -- 1 -- SPACE 24

21 SPACE -- 1 -- -- 1 -- SPACE 22

19 SPACE -- 1 -- -- 1 -- SPACE 20

17 SPACE -- 1 -- -- 1 -- SPACE 18

15 SPARE 20 A 1 0 VA -- 1 -- SPACE 16

13 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 14

11 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 12

9 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 10

7 42 VA 168 VA 1 20 A TR #1C-242 LIGHTING 8

IU-1-02 15 A 2

42 VA 1167... 6

3 TR #1C-242 RECEPTACLE 20 A 1 720 VA 1167... 4

1 TR #1C-242 ACCESS CONTROLLER 20 A 1 83 VA 1167...

3 20 A TR #1C-242 RACK RECEPTACLE

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Enclosure: Indoor MCB Rating: 60 A Mounting: Surface Wires: 4 Mains Rating: 125 A

Supply From: B01-EP-TR Phases: 3 Mains Type: MCB Location: TELECOM ROOM 1C-242 Volts: 208Y/120 A.I.C. Rating: 10kA

Branch Panel: B01-TR1C-242B

1. ADD SPD DEVICES INTEGRAL TO ALL NEW TELECOM PANELBOARDS (SQ D OR EQUAL) FOR TYPE 2 PROTECTION.

2. ADD PXR 20 TRIP UNITS FOR ADJUSTING CIRCUIT BREAKERS (EATON OR EQUAL).

Notes:

Total Est. Demand: 12 A Total Conn.: 12 A

Total Est. Demand: 4400 VA Total Conn. Load: 4400 VA

Receptacle 4400 VA 100.00% 4400 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 11 A 16 A 10 A Total Load: 1347 VA 1887 VA 1167 VA

29 SPD 20 A 1 0 VA -- 1 -- SPACE 30

27 SPD 20 A 1 0 VA -- 1 -- SPACE 28

25 SPD 20 A 1 0 VA -- 1 -- SPACE 26

23 SPACE -- 1 -- -- 1 -- SPACE 24

21 SPACE -- 1 -- -- 1 -- SPACE 22

19 SPACE -- 1 -- -- 1 -- SPACE 20

17 SPACE -- 1 -- -- 1 -- SPACE 18

15 SPACE -- 1 -- -- 1 -- SPACE 16

13 SPACE -- 1 -- -- 1 -- SPACE 14

11 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 12

9 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 10

7 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 8

5 SPARE 20 A 1 0 VA 1167... 6

3 TR #1-325 RECEPTACLE 20 A 1 720 VA 1167... 4

1 TR #1-325 RECEPTACLE 20 A 1 180 VA 1167...

3 20 A TR #1-325 RACK RECEPTACLE

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Enclosure: Indoor MCB Rating: 60 A Mounting: Surface Wires: 4 Mains Rating: 125 A

Supply From: B01-NP-TR Phases: 3 Mains Type: MCB Location: TELECOM ROOM 1-324 Volts: 208Y/120 A.I.C. Rating: 10kA

Branch Panel: B01-TR1-324A

1. ADD SPD DEVICES INTEGRAL TO ALL NEW TELECOM PANELBOARDS (SQ D OR EQUAL) FOR TYPE 2 PROTECTION.

2. ADD PXR 20 TRIP UNITS FOR ADJUSTING CIRCUIT BREAKERS (EATON OR EQUAL).

Notes:

Total Est. Demand: 14 A ACCESS CONTROLLER 83 VA 100.00% 83 VA Total Conn.: 14 A LTG 168 VA 125.00% 210 VA Total Est. Demand: 4913 VA NC 410 VA 100.00% 410 VA Total Conn. Load: 4873 VA Receptacle 4220 VA 100.00% 4220 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 13 A 16 A 11 A Total Load: 1573 VA 1929 VA 1372 VA

29 SPD 20 A 1 0 VA -- 1 -- SPACE 30

27 SPD 20 A 1 0 VA -- 1 -- SPACE 28

25 SPD 20 A 1 0 VA -- 1 -- SPACE 26

23 SPACE -- 1 -- -- 1 -- SPACE 24

21 SPACE -- 1 -- -- 1 -- SPACE 22

19 SPACE -- 1 -- -- 1 -- SPACE 20

17 SPACE -- 1 -- -- 1 -- SPACE 18

15 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 16

13 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 14

11 42 VA 0 VA 1 20 A SPARE 12

IU-1-03 15 A 2

42 VA 0 VA 1 20 A SPARE 10

7 163 VA 1167... 8

BC-1 BRANCH CONTROLLER 15 A 2

163 VA 1167... 6

3 TR #1-324 RECEPTACLE 20 A 1 720 VA 1167...

3 20 A TR #1-324 RACK RECEPTACLE

1 TR #1-324 ACCESS CONTROLLER 20 A 1 83 VA 168 VA 1 20 A TR #1-324 LIGHTING 2

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Enclosure: Indoor MCB Rating: 60 A Mounting: Surface Wires: 4 Mains Rating: 125 A

Supply From:…

This is the start of the file's text. The full file is on GovTribe.