Attachment 12 - 689A4-22-700.Newington.EHRM.IFC.B01_02.20241008.part3.pdf
PDF 13 MB Posted
- Attached to
- Z2DA--689A4-22-700 EHRM Infrastructure, Newington CONSTRUCTION SOLICITATION (VA-24-00028377)
- Solicitation number
- 36C77624B0015_1
View the file
Other files
Show 40 more
Latest 50 of 68 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELECTRICAL ABBREVIATIONS
J J
M
V
SP
R
GB
VFD
LCP
LRP
AFB
NCC
MS
1P
2P
E
DS
SS
B
MO
FBX
ET
M
M
C
DTDT
A-1
PH
D
P
K a
L
OS
R
B
CB
MD
MD
SP
VP
TV
XX
DC
C
DM
R/D
DGP
RX
ELM
DO
AC
KAC
E
K
ATS
TBB
T
TMH
EMH
EHH
X
PSD
EMU
FB
UG
GB
G
PB
SR-X
6-30R
UPS
CT
DOOR CONTACT SWITCH
ACCESS FLOOR BOX ("X" DENOTES TYPE AS SPECIFIED)
FLOOR BOX ("X" DENOTES TYPE AS SPECIFIED)
CONTACTOR
VARIABLE FREQUENCY DRIVE/VARIABLE FREQUENCY MOTOR CONTROLLER
MANUAL MOTOR STARTER WITH PILOT LIGHT AS INDICATED.
PUSHBUTTON STATION
CCTV SURVEILLANCE CAMERA OUTLET - WALL MTD, UON
DOOR MONITOR SWITCH
RECEIVER/DRIVER UNIT
NURSE CALL CONTROL EQUIPMENT PANEL (RECESSED/SURFACE)
NURSE CALL EMERGENCY STATION - PULL CORD TYPE IN
TOILETS & SHOWERS, PUSH-BUTTON TYPE IN ALL OTHER
PLACES
NURSE CALL BEDSIDE STATION, DOUBLE PATIENT
NURSE CALL BEDSIDE STATION, SINGLE PATIENT
NURSE CALL MASTER STATION
GLASS BREAK DETECTOR
NURSE CALL DOME LIGHT
PATIENT MONITORING OUTLET
CODE BLUE CALL STATION
NURSE CALL STAFF STATION
NURSE CALL DUTY STATION
LIGHTING FIXTURE TYPE DESIGNATION - "XX" INDICATES SPECIFIC TYPE
EXIT LIGHT - WALL/CEILING MOUNTED - DIRECTIONAL
ARROWS AS INDICATED SHADING INDICATES ILLUMINATED
FACE
LIGHTING TRACK - "X" DENOTES TYPE
UTILITY LIGHTING FIXTURE - TYPE AS INDICATED
WALL MOUNTED LIGHTING FIXTURE- TYPE AS INDICATED
SITE LIGHTING FIXTURE TYPE AS INDICATED
LIGHTING FIXTURE - TYPE AS INDICATED (SUBSCRIPT INDICATES SWITCH CONTROL)
JUNCTION BOX - CEILING OR WALL MOUNTED - INDICATED IN POWER, LIGHTING & FIRE
ALARM SYSTEMS PLANS.
DIRECT CONNECTION TO EQUIPMENT
SINGLE POLE SWITCH (SUBSCRIPT INDICATES FIXTURES CONTROLLED)
DIMMER SWITCH
SINGLE OR DOUBLE, REMOTE EMERGENCY LIGHTING FIXTURE
THREE-WAY SWITCH (S3P-THREE-WAY SWITCH WITH PILOT LIGHT)
KEY OPERATED SWITCH
SINGLE POLE SWITCH WITH PILOT LIGHT
FOUR - WAY SWITCH
FUSED SWITCH
DELTA CONNECTION
CPT
PASSIVE INFRARED/ULTRASONIC OCCUPANCY SENSOR (WALL/CEILING)
ELECTRIC INTERLOCK SYSTEM
CONTROL POWER TRANSFORMER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
PHOTO CELL
KEY INTERLOCKING SYSTEM
WYE CONNECTION - SOLID GROUND
SWITCH - SINGLE THROW
TELECOMMUNICATIONS BACKBOARD
MOTOR CONTROL CENTER
TELEPHONE MANHOLE
ELECTRIC MANHOLE
FUSE
BUS DUCT PLUG-IN UNIT
GROUND
AUTOMATIC TRANSFER SWITCH
DRAWOUT TYPE, CIRCUIT BREAKER
STATIONARY CIRCUIT BREAKER
DISCONNECT SWITCH, FUSED.
PROVIDE SWITCH AND FUSE AMACITY EQUAL TO OR GREATER THAN FEEDER AMPACITY,
UON
GROUND ROD
DISCONNECT SWITCH, NON-FUSED
PROVIDE SWITCH AMPACITY EQUAL TO OR GREATER THAN FEEDER AMPACITY, UON
TELECOMMUNICATIONS COMBINATION VOICE/DATA OUTLET, FLOOR MTD SERVICE FITTING,
SURFACE TYPE ("F" DENOTES FLUSH TYPE, "P" DENOTES POKE THRU TYPE)
TELECOMMUNICATIONS COMBINATION VOICE/DATA OUTLET, WALL MTD.
(SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)
TRANSFORMER - TYPE AND RATING AS INDICATED
COMBINATION MOTOR STARTER WITH DISCONNECT SWITCH.
PROVIDE SWITCH AND FUSE AMACITY EQUAL TO OR GREATER THAN FEEDER
AMPACITY, UON
PANELBOARD - (FLUSH/SURFACE)
DISTRIBUTION PANELBOARD
ELECTRIC HANDHOLE
LIGHTING CONTROL PANEL, SURFACE MTD. UON.
LOW VOLTAGE LIGHTING RELAY PANEL, SURFACE MTD. UON
UNINTERRUPTIBLE POWER SUPPLY
SHADING INDICATES FIXTURE [CONNECTED TO CRITICAL BRANCH]
[CONNECTED TO GENERATOR CIRCUIT (SWITCHED)]
[W/FLUORESCENT BATTERY/INVERTER UNIT (SWITCHED)]
SHADING INDICATES FIXTURE [CONNECTED TO LIFE SAFETY BRANCH
(UNSWITCHED)] [W/FLUORESCENT BATTERY/INVERTER UNIT (UNSWITCHED)]
a
LOW VOLTAGE SWITCH
JUNCTION BOX - CEILING MOUNTED - 60A 3P - NORMAL
TELECOMMUNICATIONS COMBINATION VOICE/DATA OUTLET, CEILING MTD SERVICE
FITTING,
SURFACE TYPE ("F" DENOTES FLUSH TYPE)
MOTOR AND CONNECTION
EMERGENCY POWER OFF
REQUEST-FOR-EXIT SENSOR
ELECTRIC LOCKING/LATCHING AND MONITORING HARDWARE
ACCESS CONTROL STATION - KEYPAD TYPE
ACCESS CONTROL STATION - CARD TYPE
DOOR OPERATING EQUIPMENT
DATA GATHERING PANEL
NURSE CALL DOME LIGHT CEILING MTD
("Z" SUBSCRIPT DENOTES ZONE DOME LIGHT)
CODE BLUE WITH RED PHONE, WALL MTD, MOUNTED 48" AFF
CODE BLUE WITH BLUE LIGHT, WALL MTD, MOUNTED 48" AFF
MOTION DETECTOR - CEILING MTD
MOTION DETECTOR - WALL MTD
POWER SUPPLY FOR DOOR(S) WITH ELECTRICAL HARDWARE
OVERHEAD EMERGENCY DUPLEX RECEPTACLE NEMA L21-20, 20A, 125V, 3P, 4W.
SPECIAL PURPOSE RECEPTACLE. TYPE AS INDICATED ON DRAWINGS.
COORDINATE RECEPTACLE TYPE WITH ACTUAL EQUIPMENT PRIOR TO INSTALLATION.
SWITCHED DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W.
EMERGENCY DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W.
FLOOR MOUNTED QUADRUPLEX ISOLATED GROUND RECEPTACLE, (2)20A, 125V,
2P, 3W, DUPLEX ISOLATED GROUND RECEPTACLES WITH A COMMON
FACEPLATE.
FLOOR MOUNTED QUADRUPLEX RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX
RECEPTACLES WITH A COMMON FACEPLATE.
FLOOR MOUNTED DUPLEX ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.
FLOOR MOUNTED DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. PROVIDE CORE
DRILL PACKAGE TO MAINTAIN FIRE RATING OF FLOOR. EXTEND CONDUIT
AND WIRING IN CEILING SPACE OF FLOOR BELOW TO ELECTRICAL CLOSET
OR PANELBOARD.
FLOOR MOUNTED SINGLE ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.
CEILING MOUNTED QUADRUPLEX ISOLATED GROUND RECEPTACLE, (2)20A, 125V,
2P, 3W, DUPLEX ISOLATED GROUND RECEPTACLES WITH A COMMON FACEPLATE.
FLOOR MOUNTED SINGLE RECEPTACLE, 20A, 125V, 2P, 3W.
CEILING MOUNTED DUPLEX ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.
CEILING MOUNTED SINGLE ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.
CEILING MOUNTED SINGLE RECEPTACLE, 20A, 125V, 2P, 3W.
SINGLE ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P,
3W. (SLASH INDICATES MOUNTING ABOVE FINISH
COUNTER)
QUADRUPLEX ISOLATED GROUND RECEPTACLE, (2)20A, 125V, 2P, 3W,
DUPLEX ISOLATED GROUND RECEPTACLES WITH A COMMON
FACEPLATE. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)
DUPLEX ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.
(SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)
DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)
SINGLE RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)
RECEPTACLES MOUNTED ABOVE THE CEILING.
QUADRUPLEX RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX RECEPTACLES
WITH A COMMON FACEPLATE. (SLASH INDICATES MOUNTING ABOVE FINISH
COUNTER)
CEILING MOUNTED QUADRUPLEX RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX
RECEPTACLES WITH A COMMON FACEPLATE.
GFI, DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)
ELECTRONIC METERING UNIT
GROUND BUS
GROUND CABLE, SIZE AS INDICATED
PLUG-IN BUSWAY
FEEDER BUSWAY
UNDERGROUND CONDUIT/DUCTBANK
CABLE TRAY
CONDUIT TURNED DOWN
CONDUIT TURNED UP
CONDUIT CAST IN CONCRETE OR BELOW SLAB
CONDUIT RUN CONCEALED IN FINISHED AREAS, EXPOSED IN UNFINISHED
AREAS OR BELOW ACCESS FLOORS
HOMERUN TO PANEL WITH CIRCUIT NUMBER(S) AS INDICATED
TELECOMMUNICATIONS DATA OUTLET ABOVE CEILING
COMBINATION TV OUTLET AND DUPLEX RECEPTACLE ON SINGLE
FACEPLATE
SPEAKER - WALL MTD
PA VOLUME CONTROL
MICROPHONE OUTLET - CEILING MTD
MICROPHONE OUTLET - WALL MTD
MICROPHONE OUTLET - FLOOR MTD
SPEAKER - CEILING MTD
RECORDING OUTLET
COMBINATION VIDEO PROJECTOR OUTLET AND DUPLEX RECEPTACLE
CLOCK OUTLET, W/RECPT AND HANGER
CLOCK OUTLET, MASTER CLOCK
CLOCK OUTLET, ELAPSED TIME
GENERATORG
SURFACE RACEWAY ("X" DENOTES TYPE AS SPECIFIED)
WALLWASH LIGHT FIXTURE,
DEMOLITION WORK
OCCUPANCY SENSOR WALL SWITCH
M
HC ADA PUSH BUTTON.
ELECTRICAL LIGHTING SYMBOLS ELECTRICAL POWER SYMBOLS GENERAL NOTES
A INTERCOMMUNICATION SYSTEM ( AI PHONE)
A B C A B C
P P
PD PD
D D
POWER SERVICE FITTING (FLOOR/WALL) MOUNTED FOR CONNECTION TO FURNITURE
SYSTEM AS SPECIFIED.
COMBINATION POWER AND TELECOMMUNICATIONS FLOOR OR WALL MOUNTED BOX FOR
POWER AND DATA CONNECTION - INDICATED IN POWER & SPECIAL SYSTEMS PLANS.
JUNCTION BOX FLOOR OR WALL MOUNTED FOR CONNECTION TO FURNITURE SYSTEM
ELTD EMERGENCY LIGHTING TRANSFER DEVICE
SECURITY SYSTEM SYMBOLS
TELECOMMUNICATION SYMBOLS
NURSE CALL SYSTEM SYMBOLS
MOUNTING HEIGHTS
ELECTRICAL EQUIPMENT SYMBOLS
ELECTRICAL WIRING SYMBOLS
DISTRIBUTION AND DIAGRAM SYMBOLS
REFERENCE SYMBOLS
SECTION NUMBER
DETAIL NUMBER
DRAWING NUMBER WHERE DRAWN
DRAWING NUMBER WHERE DRAWN
E1-1.0 KEY NOTE
1 DEMO KEY NOTE
SPECIAL SYSTEM OUTLET SYMBOLS
CB
E1-1.0
*REFER TO DETAIL ON E-501
x
WAP WIRELESS ACCESS POINT, CEILING MOUNTED
NOTE: NOT ALL ABBREVIATIONS AND
SYMBOLS APPLY TO THIS PROJECT.
SPST
SWBD
SYM
STD
SW
SPEC(S)
SPDT
SPKR
SF
SEC
SINGLE POLE SINGLE THROW
SINGLE POLE DOUBLE THROW
SYMMETRICAL
SWITCHBOARD
STANDARD
SWITCH
SECONDARY
SQUARE FOOT
SPECIFICATION(S)
SPEAKER
PRI
RCLP
RM
SCH, SCHED
RP
REF
RCPT
RSC
RLA
RF
R, RE
QTY
PWR
PT
PVC
PA
PH, ∅
PF
PNL
PE
PB
P
OPP
OHE/T
OH
OFOI
OFCI
NO., NUM, #
OC
NTS
AMERICAN WIRE GAUGE
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AUTOMATIC TRANSFER SWITCH
AMPERE INTERRUPTING CAPACITY
ALTERNATING CURRENT
ABOVE FINISHED COUNTER
AWG
BLDG
BRKR, BKR
BUILDING
BREAKER
AUTO
AUX
ARCH
AT
ATS
ALT
AFG
AIC
AFC
AFF
AC
AF
AUXILIARY
ALTERNATE
ARCHITECT
AUTOMATIC
AMPERES TRIP
AMPERE FRAME (BREAKER RATING)
MTG
NC
NEMA
NO
NIC
NEC
N
MV
MH
MOCP
MTD
MLO
MIN
MISC
MECH
MCC
MFR
MCA
MCB
RIGID STEEL CONDUIT
RATED (RUNNING) LOAD AMPS
RECEPTACLE PANELBOARD
ROOM
SCHEDULE
RADIO FREQUENCY
RECEPTACLE
REFRIGERATOR
RELOCATE AS SHOWN
POTENTIAL TRANSFORMER
POLYVINYL CHLORIDE
REMOTE CONTROL LIGHTING PANEL
QUANTITY
POWER
PUBLIC ADDRESS
PANEL
PRIMARY
PULL BOX
POWER FACTOR
PHOTO ELECTRIC
PHASE
POLE
OPPOSITE
OWNER FURNISHED, CONTRACTOR INSTALLED
OWNER FURNISHED, OWNER INSTALLED
OVERHEAD ELECTRIC/TELEPHONE
OVERHEAD
ON CENTER
NOT TO SCALE
NUMBER
MOUNTING
NATIONAL ELECTRICAL CODE
MEDIUM VOLTAGE (OVER 600V LESS THAN 35KV)
NORMALLY CLOSED
NORMALLY OPEN
NOT IN CONTRACT
NEUTRAL
MINIMUM CIRCUIT AMPACITY
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MAXIMUM OVERCURRENT PROTECTION
MOUNTED
MISCELLANEOUS
MAIN LUGS ONLY
MINIMUM
MANHOLE
MANUFACTURER
MECHANICAL
SWGR SWITCHGEAR
AIR HANDLING UNITAHU
MTS MANUAL TRANSFER SWITCH
PDP POWER DISTRIBUTION PANEL
AMPERESAMP
OCPD OVERCURRENT PROTECTION DEVICE
A M
B N
O
P
Q
R
S
T
SPD SURGE PROTECTIVE DEVICE
OD OUTLET DESIGNATOR
LOW VOLTAGE (BELOW 50 VOLTS)
L-L L-N
LTG
LV
LIGHTING
LINE TO LINE
LINE TO NEUTRAL
1000 CIRCULAR mils
KILOVOLTS (THOUSAND VOLTS)
KILOWATTS (THOUSAND WATTS)
LIGHTNING ARRESTOR
LOCAL AREA NETWORK
KILOVOLTS-AMPERES (THOUSAND VOLT-AMPS)
ISOLATED GROUND
KWH
LAN
LA
KW
KVA
Kcmil
KV
KILOWATT-HOURS
INCAND
KEY INTERLOCK
JUNCTION BOX
INCH/INCHES (")
INCANDESCENT
GROUND FAULT INTERRUPTER
HAND-OFF-AUTOMATIC
HIGH PRESSURE SODIUM
HEATING VENTILATION AND AIR CONDITIONING
HERTZ
HVAC
HZ
HTR
HR
HT
HPS
HOA
HP
HEATER
HEIGHT
HORSEPOWER
HOUR
GFI
G, GND, GRD
GEN
FLUOR
FL, FLR
GROUND
GENERATOR
FOOT/FEET (')
FLUORESCENT
FLOOR
CATV
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
FIRE ALARM ANNUNCIATOR PANEL
ELECTRIC, ELECTRICAL
ELECTRIC METALLIC CONDUIT
EQUIPMENT GROUND
EWC
FAAP
FLA
FDR
EWH
FA
FULL LOAD AMPS
FEEDER
FIRE ALARM
FUSE
ELEC
EQ, EQUIP
EM, EMERG
EMT
ELEV
ENCL
EG
EQUIPMENT
ELEVATOR
EMERGENCY
ENCLOSURE
DISTRIBUTION PANEL
DOUBLE POLE SINGLE THROW
DOUBLE POLE DOUBLE THROW
CONTROL POWER TRANSFORMER
CURRENT TRANSFORMER
DPDT
DWG
DPST
DIST
DISC
DC
DP
DN
DRAWING
DISTRIBUTION
DIRECT CURRENT
DISCONNECT
DOWN
CPT
CU
CT
COM, COMM
CKT
CLG
COPPER
COMMUNICATIONS
CIRCUIT
CEILING
CABLE TELEVISION
CB CIRCUIT BREAKER
CONDUIT
FIRE ALARM CONTROL PANELFACP
FIRE ALARM EXTENDER PANELFAEP
CCTV CLOSED CIRCUIT TELEVISION
CP CONTROL PANEL
FLEX FLEXIBLE
HAND HOLEHH
LIGHTING CONTROL PANELLC, LCP
LIGHTING PANEL
L-G LINE TO GROUND
C
F
EXISTINGE, EX, EXIST
FT
IN
IG
JB, JBOX
K
LP
FOOT CANDLEFC
DIV DIVISION
C
D
E
F
G
H
I
J
K
L
HORIZONTAL MOUNTINGH
COR CONTRACTING OFFICER'S REPRESENTATIVE
X
XFMR
WP
WHM
W/ W/O
W
VFD
VA
V
UPS
UL
UON
UG
UGS
UGT
UGP
TYP
TV
TP
TEL,TELE
TELECOM
TC
TRANSFORMER
REMOVE DEVICE
WATT HOUR METER
WEATHERPROOF
VOLTS
VARIABLE FREQUENCY DRIVE/
VARIABLE FREQUENCY MOTOR
CONTROLLER
WITHOUT
WITH
WIRE
VOLT-AMPERES
UNDERGROUND PRIMARY
UNDERGROUND SECONDARY
UNDERGROUND TELEPHONE
UNDERWRITER'S LABORATORY
UNLESS OTHERWISE NOTED
UNINTERRUPTIBLE POWER SUPPLY
UNDERGROUND
TELECOMMUNICATIONS
TYPICAL
TELEVISION
TAMPERPROOF
TIME CLOCK
TELEPHONE
TB TERMINAL BLOCK
TBB TELEPHONE BACKBOARD
U
V
W
X
Z
TPST TRIPLE POLE SINGLE THROW
FDS FORWARD DEPLOYED SERVICES
JOINT SECURITY ARCHITECTUREJSA
PIV PERSONAL IDENTITY VERIFICATION
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
PROVIDE 1#12 + 1#12N + 1#12G FOR 20A BRANCH CIRCUITING, UON; MAXIMUM OF THREE
CIRCUITS PER CONDUIT; MINIMUM CONDUIT SIZE OF 3/4" C, UON.
PROVIDE A DEDICATED NEUTRAL WIRE FOR EACH BRANCH CIRCUIT. IF AN EXISTING
CIRCUIT DOES NOT HAVE A DEDICATED NEUTRAL, CONTRACTOR SHALL PROVIDE A
NEW BRANCH CIRCUIT WITH DEDICATED NEUTRAL CONDUCTOR. COORDINATE DEVICE
LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTURAL DRAWINGS PRIOR TO
ROUGH-IN.
PROVIDE FIRE STOPPING FOR CONDUITS AND ELECTRICAL EQUIPMENT FOR FLOOR
SLABS, WALLS AND CEILINGS TO MAINTAIN FIRE RATING.
INSTALL ELECTRICAL WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE
AND LOCAL BUILDING AND FIRE CODES, IN A NEAT AND WORKMANLIKE MANNER.
LIMIT VOLTAGE DROP TO 2% FOR FEEDERS AND 2% FOR BRANCH CIRCUITS. INCLUDE
DERATING FACTOR FOR ROOF-MOUNTED CONDUITS PER 310.15(B)(2). FOR ANY
INCREASE IN UNGROUNDED CONDUCTOR SIZE, INCREASE GROUNDED CONDUCTOR
PROPORTIONALLY PER NEC.
REFER TO ARCH. REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING
MOUNTED DEVICES AND LIGHT FIXTURES, UNLESS OTHERWISE INDICATED.
WHERE MULTIPLE SWITCHES, RECEPTACLES, AND OTHER OUTLETS (EXCEPT WALL
PHONES) ARE INDICATED PROVIDE MULTI-GANG BACK BOXES WITH GANG BARRIERS
AND A COMMON FACEPLATE.
WHERE DIFFERENT RECESSED ELECTRICAL DEVICES WITH THE SAME MOUNTING
HEIGHTS ARE INDICATED SIDE-BY-SIDE, MOUNT THE DEVICES SO THAT THERE IS FOUR
INCHES BETWEEN ADJACENT VERTICAL EDGES OF THE FACEPLATES, UON.
WHERE TECHNOLOGY DEVICES (LOW VOLTAGE/SIGNAL) ARE LOCATED IN THE SAME
AREA ALIGN DEVICES VERTICALLY THROUGH THEIR CENTERLINES, UON.
WHERE EXIT SIGNS ARE INDICATED ABOVE DOOR MOUNT AS FOLLOWS, CENTER THE
EXIT SIGN BETWEEN TOP OF DOOR FRAME AND CEILING IF DISTANCE BETWEEN TOP OF
DOOR FRAME AND CEILING IS 24 INCHES OR LESS; OTHERWISE MOUNT BOTTOM OF EXIT
SIGN 6 INCHES FROM TOP OF DOOR FRAME, MOUNT OTHER WALL MOUNTED EXIT SIGNS
IN THE SAME AREA AT THE SAME HEIGHT. COORDINATE WITH ARCHITECTURAL DETAILS.
PROVIDE TYPE "L1" FIXTURE IN SCHEDULE, UON.
PROVIDE SEPARATE NEUTRALS FOR DIMMING CIRCUITS.
PROVIDE FEEDERS AND BRANCH CIRCUITS WHICH HAVE AN AMPACITY EQUAL TO OR
GREATER THAN THE CIRCUIT OVERCURRENT PROTECTIVE DEVICE RATING, U.O.N.
FURNITURE LAYOUTS ARE FOR REFERENCE ONLY. COORDINATE THE FINAL LOCATION
OF ELECTRICAL DEVICES AND OUTLETS WITH ARCHITECT, OWNER AND FINAL
FURNITURE PLANS PRIOR TO INSTALLATION.
MOUNT DEVICES FLUSH WITH CONCEALED CONDUIT, EXCEPT AS NOTED ON THE
DRAWINGS AND IN MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS.
THE DRAWINGS REPRESENT ELECTRICAL DESIGN INTENT. THEY ARE DIAGRAMMATIC.
PROVIDE ALL COMPONENTS NECESSARY FOR COMPLETE OPERATING ELECTRICAL
SYSTEMS.
WHEN MORE THAN ONE 20A., 1P., 120 VOLT CIRCUIT FEEDS A SURFACE RACEWAY
CONNECT RECEPTACLES TO ALTERNATE CIRCUITS AS FOLLOWS - U.O.N.
ES ELECTRIC STRIKE
JUNCTION BOX - CEILING MOUNTED - 60A 3P - EMERGENCY
CR CARD READER
OVERHEAD DUPLEX RECEPTACLE NEMA L21-20, 20A, 125V, 3P, 4W.
OVERHEAD DUPLEX RECEPTACLE NEMA L21-30, 30A, 125V, 3P, 4W.
OVERHEAD EMERGENCY DUPLEX RECEPTACLE NEMA L21-30, 30A, 125V, 3P, 4W.
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NFDS NON-FUSED DISCONNECT SWITCH
07/03/2024
07/03/2024
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
CONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202
MAT PERKINS
(315) 484-5958
STAMP
01_02
Au to de sk
D oc s:
//6
A4
-2 2-
0_
N ew in gt on _V
AM
C
_E H
R M
_I U
-1
2/
9A 4-
-7
.N ew in gt on
.E H
R M
.M
EP
.G en er al
.S he et s.
rv t
-1
0-
6:
:3
01E-001
ELECTRICAL ABBREVIATIONS AND SYMBOLS 689A4-22-700
07/03/2024 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
555 Willard Avenue, Newington, CT 06111
Revisions: Date:
UP
WALL SYMBOL LEGEND
EXISTING CONSTRUCTION TO REMAIN
SMOKE AND 1-HR RATED FIRE
BARRIER AND OPENINGS
SMOKE AND 2-HR RATED FIRE BARRIER
AND OPENINGS
SMOKE BARRIER AND OPENINGS
1 HR RATED FIRE BARRIER AND
OPENINGS
2 HR RATED FIRE BARRIER AND OPENINGS
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES
ELEV MACH RM
2C-B00
ELEV #S3
E8
STAIR #7
CS007
SVC LOBBY
CB-25
CANTEEN STORAGE
CB-24A
CORRIDOR
CB-24
CANTEEN OFFICE
B-103HAC
B-102
RETAIL STOCK RM
B-101
RETAIL STORAGE
B-112
AREAWAY EXTERIOR
OF BLDG.
CANTEEN OFFICE
E10
ELECT.
B-162
LA
B P R
ES
C R P
IC
K U P
2E -B 6B
LAB ENTRY AND MAIL
2E-B118
LAB
2E-B15A
LAB
2E-B119
AREAWAY EXTERIOR
OF BLDG.
LAB OFFICE
2E-B124E
LAB OFFICE
2E-B124F
LAB STORAGE
2E-B124D
STAIR #1
B001
DRIVE DOWN
CONCRETE PAVEMENT
OFFICE LAB
2E-B124C
HAC
2E-B123
LAB OFFICE
2E-B124
LAB EQUIP. RM
2E-B124B
STORAGE LAB
2E-B124A
CORRIDOR
B033
CORRIDOR
B032
CORRIDOR
B030
C O R R
ID
O R
B
CORRIDOR
B117
LAB EMPLOYEE
LOUNGE
2E-B131
LAB STAFF LOCKER
2E-B130
TOILET
2E-B131A
TOILET
2E-B130A
LAB BREAK RM
2E-B129
REF. STORAGE
2E-B128 MEDICAL RECORDS
2E-B127
TELECOM ROOM
2E-B140
ST
A
FF
T O
IL
ET
2E -B 5B
STAFF TOILET
2E-B135A
STAIR #2
B002
C O M M U N
IC
A
TI
O N
2E -B
WAITING
2E-B042
ELECTRICAL
2E-B139
C O R R
ID
O R
B
CONFERENCE RM
2E-B137A
HIMS SPVSP
2E-B137B
HIMS SUPV OFFICE
2E-B137C
OFFICE
2E-B140G
WORK RM
2E-B137
MECH EQUIP.
2E-B133
ELEV #P3
2E-B013
ELEV #P2
2E-B012
ELEV. #P1
2E-B011
ELEV #S2
2E-B015
ELEV #S1
2E-B014
C O M M U N
IC
A
TI
O N
C
LO
SE
T
2E -B
LI
N
EN
2E -B
TR
A
SH
2E -B
B U
IL
D
IN
G S
TO
R A G E
2E -B
EL
EC
TR
IC
A L
2E -B
STAIR #3
B003
CORRIDOR
B056
PATIENT ELEVATOR
LOBBY
B021
CORRIDOR
B022
FE
M A
LE
S
TA
FF
LO
C K
ER
2E -B
STAFF LOUNGE
2E-B154
TOILET
2E-B155A
TOILET
2E-B153A
AREA
B050
HAC
2E-B149
CORRIDOR
B048
DISPATCH
2E-B049
CLEAN RECEIVING AND
BREAKOUT
2E-B148
BULK STORAGE
2E-B148A
WORK RM
2E-B147
CHIEF SPD
2E-B146A
SPD CLERKS
2E-B146
SU
M P R M
2E -B
C O R R
ID
O R
B
CORRIDOR
B043
MALE STAFF LOCKER
2E-B153
MECH. EQUIP.
2E-B157B
SOILED RECEIVING/
DECONTAM
2E-B156
STERILE
2E-B157A
PREP. ASSEMBLY AND
STERILIZATION
2E-B157
HAC
2E-B152
MANUAL EQUIP. WASH
2E-B150
AUTO CART WASH
2E-B151
STERILE/ NON-
STERILE STORAGE
2E-B144
CORRIDOR
B052
ETO
2E-B158
ETO
2E-B158A
HOLDING RM
2E-B144A
WOMEN'S TOILET
B-108
MENS TOILET
B-109
ENTRY/ EXIT
B-118
FOOD PREP
B-107
STORAGE
B-106
SERVING
B-105
CASHIER
B-110
FOOD COURT
B-111
DINING RM
B-115
CORRIDOR
B-119
PREP.
B-100
DISH WASHING
B-104
GENERATOR ROOM
ROOM
ROOM
ROOM
ROOM
STAIRS
VESTIBULE
TELECOM ROOM
2E-B127A
EMERGENCY
GENERATOR
2E-1161B
ELECTRICAL SWITCH
GEAR
2E-1161
02E-404 F4
02E-403 F102E-401
D7
02E-401 F7
07/03/2024
07/03/2024
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
CONSULTANT
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
2W
TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202
MAT PERKINS
(315) 484-5958
2C 2E
STAMP
Au to de sk
D oc s:
//6
A4
-2 2-
0_
N ew in gt on _V
AM
C
_E H
R M
_I U
-1
2/
9A 4-
-7
.N ew in gt on
.E H
R M
.M
EP
.B
_0 2_
R
.rv t
-1
0-
6:
:3
01E-100
ELECTRICAL PLAN - OVERALL BUILDING FLOOR
PLAN - BASEMENT
689A4-22-700
01_02
07/03/2024 M. Perkins J. Schooley
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
555 Willard Avenue, Newington, CT 06111
SCALE: 1/16" = 1'-0"F1
ELECTRICAL PLAN - OVERALL
BUILDING FLOOR PLAN - BASEMENT
LEVEL
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING
WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL
PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION
WHERE FEASIBLE. CONSTRUCTION AREA CONDITIONS MAY DIFFER FROM
THOSE INDICATED.
MINIMUM BRANCH CIRCUIT SIZE SHALL BE 2#12, 1#12G., 3/4"C.
CONTRACTOR SHALL COORDINATE FINAL POINT OF CONNECTIONS
WITH VA COR PRIOR TO ROUGH-IN.
PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT INSTALLED
OUTDOORS
SIZE BRANCH CIRCUITS AND FEEDERS TO EQUIPMENT PER PANEL
SCHEDULE AND FEEDER AND BRANCH CIRCUIT SIZING TABLE ON E-701.
COORDINATE FINAL EQUIPMENT CONNECTIONS AT EQUIPMENT WITH
EQUIPMENT SUPPLIER, PRIOR TO ROUGH-IN.
LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL LISTING
PANEL AND CIRCUIT FEEDING THE WIRING DEVICE.
UPDATE PANEL SCHEDULES AFFECTED BY RENOVATION.
NEW CIRCUIT BREAKERS PROVIDED SHALL MATCH THE EXISTING TYPE
AND AIC RATING OF CIRCUIT BREAKERS IN PANEL BEING RENOVATED.
CONTRACTOR SHALL FIELD COORDINATE CABLE TRAY LAYOUT WITH
EXISTING UTILITIES ROUTED THROUGH THE RENOVATED SPACE.
CONTRACTOR SHALL COMPLY WITH NEC 300.22 FOR CONDUIT ROUTED IN
PLENUM SPACES.
REFER TO E-901 FOR CUTSHEETS.
COMPLY WITH NEC 220.87 FOR ALL 30-DAY LOAD MEASUREMENTS OF
PANELBOARDS.
LOCATE DISCONNECT SWITCHES TO MAINTAIN WORKING CLEARANCES
PER NEC 110.26.
CONTRACTOR SHALL LABEL ALL JUNCTION BOX COVERS WITH THE CIRCUITS
CONTAINED AND SOURCE PANEL IDENTIFIED.
EXISTING CONSTRUCTION TO REMAIN
SMOKE AND 1-HR RATED FIRE
BARRIER AND OPENINGS
SMOKE AND 2-HR RATED FIRE BARRIER
AND OPENINGS
SMOKE BARRIER AND OPENINGS
1 HR RATED FIRE BARRIER AND
OPENINGS
2 HR RATED FIRE BARRIER AND OPENINGS
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES
TELECOM ROOM
2C-1155
EXAM RM
2C-1158
ANTI COAGULATION
CLINIC EXAM RM
2C-1154
EXAM RM
2C-1159
IT
2C-1156
O
FF
IC
E
2C -1
MECH. EQUIP.
2E-1160
SMALL STATION
2E-1169
SMALL STATION
2E-1170
SMALL STATION
2E-1171
LARGE STATION
2E-1172
ELECT
2E-1166
STAIR #2
COMMUNICATION
2E-1165
SOILED UTILITY
2E-1163
HAC
2E-1162
CHASE
MEDS
2E-1168
CLEAN UTILITY
2E-1164
EXAM RM
2E-1159
EXAM RM
2E-1158
STAFF TOILET
2E-1180
ST
A
FF
L O C K
ER
2E -1
EXAM RM
2E-1157
PHARMACY OFFICE
2E-1182
C O R R
ID
O R
EXAM RM
2E-1184
EXAM RM
2E-1185
NURSE OFFICE
2E-1183
CLINICAL PHARMACIST
OFFICE
2E-1156
EXAM RM
2E-1186
ELECTRICAL
2E-1187
TOILET
2E-1190
HAC
2E-1200
EXAM RM (TB)
2E-1191
EXAM RM
2E-1192
EXAM RM
2E-1193
EXAM RM
2E-1194
ECG RM
2E-1195 C H
EC
K
- I N W A
LK
-IN
2E -1
TELECOM ROOM
2E-1178
URGENT CARE
STATION
2E-1050
SMALL STATION
2E-1173
LIFE SUPPORT
2E-1174
LIFE SUPPORT
2E-1175
STRETCHER STORAGE
2E-1197
TOILET
2E-1176
TRIAGE RM
2E-1177
VESTIBULE
2E-1053
CHASE
WAITING RM
2E-1198FEMALE TOILET
2E-1198A
MALE TOILET
2E-1198B
DIR. OFFICE
2E-1199A
OFFICE
2E-1199B
PR
IM
A R Y M
EN
TA
L
H
EA
LT
H C A R E O
FF
IC
E
2E -1
SHAFT
LINEN CHUTE
LINEN CHUTE
TRASH
2E-1203
LINEN
2E-1202
EL
EC
T
2E -1
STAIR #3
ELEV. #S1
2E-1014
ELEV #S2
2E-1015
EXAM RM
2E-1189
EXAM RM
2E-1188
ELEV #P3
2E-1013
ELEV #P2
2E-1012
ELEV #P1
2E-1011
C O M M U N
IC
A
TI
O N
C
LO
SE
T
2E -1
SVC ELEV LOBBY
2E-1064 PSYCHIATRIC
INITIATIVE
2E-1063
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
C O R R
ID
O R
C 1-
CORRIDOR
CORRIDOR
C O R R
ID
O R
CORRIDOR
CONFERENCE RM
2E-1147
EXAM RM
2E-1146
EXAM RM
2E-1140
EXAM RM
2E-1145
EXAM RM
2E-1144
TOILET
2E-1139
CORRIDOR
C O R R
ID
O R
TELEPHONE
EXAM RM (TB)
2E-1143
EXAM RM
2E-1142
POLICE STORAGE
2E-1149A
PO
LI
C E
LO
C K
ER
2E -1
MALE TOILET
2E-1103
FEMALE TOILET
2E-1104
MALE TOILET
2E-1105
FEMALE TOILET
2E-1111
CORRIDOR
EXAM RM
2E-1117
ST
A
FF
T O
IL
ET
2E -1
MALE TOILET
2E-1112
EXAM RM
2E-1115
EXAM RM
2E-1116 TO
IL
ET
2E -1 6A
EXAM RM
2E-1123
TO
IL
ET
2E -1 3A
EXAM RM
2E-1124
EXAM RM
2E-1125
CORRIDOR
C O R R
ID
O R
CLEAN UTILITY
2E-1133
INTAKE
2E-1132
STAFF TOILET
2E-1109A
MEDS
2E-1109B
TRIAGE 2
2E-1138
TRIANGE 1
2E-1109
WORK RM
2E-1109
WORK RM
2E-1109
EXAM RM
2E-1135
FIRM MGR
2E-1136
EXAM RM
2E-1137
N U R
SE
M G R O
FF
IC
E
2E -1
EXAM RM (TB)
2E-1119
EXAM RM
2E-1120
EXAM RM
2E-1121
EXAM RM
2E-1122
EXAM RM
2E-1131
EXAM RM
2E-1130
EXAM RM
2E-1129
EXAM RM
2E-1128
EXAM RM
2E-1141
EXAM RM
2E-1154
SHAFT
PATIENT ELEVATOR
LOBBY
EXAM RM
2E-1155
INFO BOOTH
2E-1031
VET ID CARD OFFICE
2E-1151
REGISTRATION
2E-1150
CORRIDOR
WAITING
2E-1026
C O R R
ID
O R
VA POLICE
2E-1027
FIRM 2 ADMIN.
2E-1101
REGISTRATION
2E-1030
WAITING
2E-1029
CORRIDOR
CORRIDOR
WAITING
2E-1041
CHECK-IN 1ST FLOOR
PRIMARY CARE
2E-1036
C O R R
ID
O R
CORRIDOR
C1-2
2E-1023
OFFICE
2C-1136
ELECT
2C-1135
ROOM
2E-1028
PATIENT ADVOCATE
OFFICE
2C-1130
OFFICE
2C-1129
COMP AND PAN
2C-1128
AUDIOLOGY
CONFERENCE RM
2C-1127
COMP AND PAN RM
2C-1126
EYE CLINIC
2C-1125
EXAM TELEHEALTH
2C-1124
TELEHEALTH
STORAGE
2C-1123
TELEHEALTH OFFICE
2C-1140
ROOM
2E-1043
COMP AND PAN OFFICE
2C-1138
AUDIOLOGY OFFICE
2C-1137
MECH BELOW
C O R R
ID
O R
2C -C 1-
WAITING
2C-1141
CHASE
ELEV #S3
STAIR #7
SVC LOBBY
2C-C1-9
TOILET
2C-1119B
STORAGE
2C-1119A
CASHIER
2C-1120
COMMUNICATION
2C-1121
COMMUNICATION CTR
2C-1119
C O R R
ID
O R
2C -1
ELECTRICAL
2C-1122
CASE MGR OFFICE
2C-1116
RN OFFICE
2C-1115
WAITING
2C-1029
OFFICE
2C-1117
SOCIAL WORKER
2C-1118
STAIR #6
DAV TRANSPORTATION
2C-1108B
TOILET
2C-1108C
DRIVERS OFFICE
2C-1108A
FIRMI ADMIN. OFFICE
2C-1101
STORAGE FOR
PRIMARY CARE
2C-1100
BLOOD DRAW
2C-1111
STAIR #5
PR
O
ST
H
ET
IC
S
2C -1
CORRIDOR
2C-C1-3
OFFICE
2C-1112
HAC
2C-1113
PROSTHETICS
2C-1114
HR/ PIV OFFICE
2C-1131
MALE TOILET
2C-1132
FEMALE TOILET
2C-1133
CORRIDOR
2C-1031
CORRIDOR
2C-1032
CORRIDOR
2C-1027
DAV TRANSPORTATION
2C-1108
ACCENT OFFICE
2C-1107
DAV TRANSPORTATION
OFFICE
2C-1108D
TOILET
2C-1106
TOILET
2C-1105
VENDING RM
2C-1104
ST
O R A G E
M A
LE
T O
IL
ET
2C -1
COUMADIN
2C-1153
ANTI COAGULATION
CLINIC
2C-1160
STAIR #4
COMP AND PEN CLINIC
EXAM RM
2C-1152
COMP AND PEN CLINIC
2C-1151
ANTI COAGULATION
CLINIC
2C-1162
ELEV MACH RM
2C-1163
TOILET
2C-1161
C O R R
ID
O R
2C -C 1-
ELEV
PA
TI
EN
T
EL
EV
L O B B Y
2C -C 1-
EXAM
2W-114
FEMALE PATIENT
TOILET
2W-116
TE
LE
C O M R O O M
2W -1
EXAM
2W-123
CHASE
OPEN OFFICE
2W-117
EXAM
2W-118
EXAM
2W-120
EXAM
2W-119
CORRIDOR
2W-1C4
SOILED UTILITY
2W-122
A N
TE
2W -1
WOMEN ISO/ PROC
2W-125
WAITING
2C-C1-11 WAITING
2C-C1-15
CORRIDOR
2C-C1-17
ELECTRICAL SWITCH
GEAR
2E-1161
EMERGENCY
GENERATOR
2E-1161B
CORRIDOR
NURSE MGR OFFICE
2E-1113
CONFERENCE RM
2E-1114
EXAM RM
2E-1127
HAC
2E-1126
C1-1
C1-2
C O R R
ID
O R
2E -C 1-
FE
M A
LE
T O
IL
ET
2C -1
TOILET
2C-1145
TRIAGE
2C-1144
TOILET
2C-1143
CORRIDOR
2C-C1-1041
RECEPTION
2C-1146
STAIR #8
2C-S8
VESTIBULE
2W-215
ELECTRICAL
2C-1164
OPEN OFFICE
2C-1165
EXAM
2C-1168
EXAM
2C-1167
EXAM
2C-1166
C O R R
2C -C 2-
EXAM
2C-1173
EXAM
2C-1172
EXAM
2C-1171
PCMH
2C-1170
SM
A
LL
M
ED
2C -1
C O R R
2C -C 2-
EXAM
2C-1174
EXAM
2C-1175
EXAM
2C-1176
EXAM
2C-1177
EXAM
2C-1179
EXAM
2C-1180
OPEN OFFICE
2C-1178
HSS
2C-1182
LINEN
2C-1181
OPEN OFFICE
2W-102
EXAM
2W-105A
EXAM
2W-105B
CONFERENCE ROOM
2W-107A
EXAM
2W-107B
EXAM
2W-108A
EXAM
2W-109A
EXAM
2W-112
TOILET
2W-106
TOILET
2W-104
EXAM
2W-101
NURSE MANAGER
2W-100
CORRIDOR
1C1-02W
CORRIDOR
2W-1C2
PHARM D
2W-132B
OIT COMM
2W-132A
EXAM
2W-130B
EXAM
2W-130A
EXAM
2W-103B
C
LE
A N S
TO
R A G E
2W -1 A
C H A
SE -
EXAM
2W-108B
EQUIP
2W-109B
TOILET
2W-110
TO
IL
ET
2W -1
13 CHASE
ELEC
2W-129
H A C
2W -1 A
CLEAN UTIL
2W-131B
MED
2W-131C
FM
S C O M M
2W -1
ST
A
IR
2W -S
EXAM
2W-127
TOILET
2W-126
C O R R
ID
O R
2W -1 C
C O R R
ID
O R
2W -1 C
TRNG BATH
1N-101A
TRNG KITCHEN
1N-101
OCCUPATIONAL
THERAPY
1N-109
STORAGE
1N-109B
OCCUPATIONAL
THERAPY
1N-109A
COMMUNICATION
ELECTRICAL
1N-110
1N-112
1N-115
C O R R
ID
O R
1N -C 1-
1N-114
1N-116
PROSTHETIC STORAGE
RM
1C-146
1-146A
ELEV
ELEV
STAIR #2
OFFICE EXAM
OFFICE EXAM
172 OFFICE EXAM
CONTROL RM
174A
EXAM RM
174B
1S-175A
WAITING ARA
1S-168
1S-170A
TOILET
1S-169
1S-170C
ISOTOPIC ST
1S-175
OFFICE
1S-177
ELECTRICAL RM
1S-179
CORRIDOR
1S-C1-4
MECH
1S-176
ISOTOPIC ST
1S-178
PUMP RM
1S-180
RECEPTION
1S-171A
C O R R
ID
O R
1S -C 1-
TELEPHONE RM
1S-164
MECH RM
1S-167
TELEPHONE RM
1C-143
TELECOM ROOM
1C-142
1C-141
C O R R
ID
O R
1C -C 1-
CORRIDOR
1C-C1-7
LOCK SMITH
1C-145
STAIR #1
HOSPITAL WHEEL
CHAIR STORAGE
1C-147
TOILET
1C-148G
CORRIDOR
1C-C1-8
ELECT.
1S-162-0
H O T W A
TE
R H
EA
TE
R S
1S -1 -0
MECH
1S-165
TOILET
1S-166
COMM-ELEC
WALK IN COOLER
1S-170B
CONTROL RM
174C
CONTROL RM
174F
EXAM RM
174D
EXAM RM
174E
AUDIOLOGY TEST
BOOTH
1N-117
1N-117A
C O R R
ID
O R
1N -C 1-
COMPUTER RM
1C-148D
MSA
WAITING
STAFF
STAFF TLT
CORRIDOR
STORAGE
SOILED UTILITY
STRETCHER AREA
PIPE CHASE
106A
CONTROL
CORRIDOR
109 CT
INJECTION
CHANGING ROOM
TOILET
HSA
TOILET
READING
CORRIDOR
1N-C1-3
ELECTRICAL SERVICE
ROOM
02E-401 F4
01E-402 F3
01E-400 F1
01E-400 F6
01E-400 F3
01E-400 D7
01E-404 F2
01E-400 C1
02E-405 C7
02E-405 F7
02E-401 D4
02E-406 F5
02E-406 C7
02E-406 F7
MALE TOILET
2W-115
07/03/2024
07/03/2024
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
CONSULTANT
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
2W
TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202
MAT PERKINS
(315) 484-5958
2C 2E
STAMP
Au to de sk
D oc s:
//6
A4
-2 2-
0_
N ew in gt on _V
AM
C
_E H
R M
_I U
-1
2/
9A 4-
-7
.N ew in gt on
.E H
R M
.M
EP
.B
_0 2_
R
.rv t
-1
0-
6:
:3
E-101
ELECTRICAL PLAN - OVERALL BUILDING FLOOR
PLAN - FIRST LEVEL
689A4-22-700
01_02
07/03/2024 M. Perkins J. Schooley
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
555 Willard Avenue, Newington, CT 06111
SCALE: 1" = 20'-0"F2
ELECTRICAL PLAN - OVERALL
BUILDING FLOOR PLAN - FIRST LEVEL
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING
WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL
PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION
WHERE FEASIBLE. CONSTRUCTION AREA CONDITIONS MAY DIFFER FROM
THOSE INDICATED.
MINIMUM BRANCH CIRCUIT SIZE SHALL BE 2#12, 1#12G., 3/4"C.
CONTRACTOR SHALL COORDINATE FINAL POINT OF CONNECTIONS
WITH VA COR PRIOR TO ROUGH-IN.
PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT INSTALLED
OUTDOORS
SIZE BRANCH CIRCUITS AND FEEDERS TO EQUIPMENT PER PANEL
SCHEDULE AND FEEDER AND BRANCH CIRCUIT SIZING TABLE ON E-701.
COORDINATE FINAL EQUIPMENT CONNECTIONS AT EQUIPMENT WITH
EQUIPMENT SUPPLIER, PRIOR TO ROUGH-IN.
LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL LISTING
PANEL AND CIRCUIT FEEDING THE WIRING DEVICE.
UPDATE PANEL SCHEDULES AFFECTED BY RENOVATION.
NEW CIRCUIT BREAKERS PROVIDED SHALL MATCH THE EXISTING TYPE
AND AIC RATING OF CIRCUIT BREAKERS IN PANEL BEING RENOVATED.
CONTRACTOR SHALL FIELD COORDINATE CABLE TRAY LAYOUT WITH
EXISTING UTILITIES ROUTED THROUGH THE RENOVATED SPACE.
CONTRACTOR SHALL COMPLY WITH NEC 300.22 FOR CONDUIT ROUTED IN
PLENUM SPACES.
REFER TO E-901 FOR CUTSHEETS.
COMPLY WITH NEC 220.87 FOR ALL 30-DAY LOAD MEASUREMENTS OF
PANELBOARDS.
LOCATE DISCONNECT SWITCHES TO MAINTAIN WORKING CLEARANCES
PER NEC 110.26.
CONTRACTOR SHALL LABEL ALL JUNCTION BOX COVERS WITH THE CIRCUITS
UPUP
EXISTING CONSTRUCTION TO REMAIN
SMOKE AND 1-HR RATED FIRE
BARRIER AND OPENINGS
SMOKE AND 2-HR RATED FIRE BARRIER
AND OPENINGS
SMOKE BARRIER AND OPENINGS
1 HR RATED FIRE BARRIER AND
OPENINGS
2 HR RATED FIRE BARRIER AND OPENINGS
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES
ACTIVE STORAGE
2C-207
DISPENSING
2C-206
FILING ASSEMBLY
2C-205
MAIL OUT
2C-205A
REPACK/PREPACK
2C-209A
PHARMACY OFFICE
2C-2128
VAULT
2C-2126A
INVEST DRUGS WORK
STORAGE SECURED
DISP FLAM
2C-2126
CORRIDOR
2C-C2-9
HAC
2C-2130
STAIR#8
STAFF TOILET
2C-2125
ELECT
2C-2124
ADMIXTURE STORAGE
2C-2123
STERILE FLUIDS OR
ADMIXTURE STORAGE
2C-214
PREP AREA
2C-215
PHARMACY STORAGE
2C-2121
DRUG PROCUREMENT
RECEIVING
2C-2120
BREAK ROOM
2C-2117
CHIEF OFFICE
2C-2118
STAIR #6
C O R R
ID
O R
2C -C 2-
STAIR#4
CORRIDOR
2C-C2-3
TELECOM ROOM
2C-2139
SECY OR WAITING
2C-2138
TO
IL
ET
2C -2
DRUG INFO OR OFFICE
2C-2138C
OFFICE
2C-2138B
TO
IL
ET
2C -2
CONSULT
2C-204
PHARMACY WAITING
2C-C2-7
PRESCRIPTION
RECEIVING
2C-204A
PHARMACY
RECEPTION
2C-223
RECEPTION
2C-222
SUPV
2C-2114
C O R R
ID
O R
2C -C 2-
ELECT
2C-2115
C O
PI
ER
A R
EA
2C -2
C O R R
ID
O R
2C -C 2-
DOCTOR OFFICE
2C2101
WAITING
2C-C2-6
ELEV
LOBBY
2C-C2-5
C O R R
ID
O R
2C -C 2-
EXAM RM
2C-2101
EXAM RM
2C-2112
EXAM RM
2C-2110
STAIR#5
EXAM RM
2C-2109
RECEPTION
2C-2103
WAITING AREA
2C-2108
SUPPLY CLOSET
CORRIDOR
2C-C2-10
A C C U M U
LA
TI
O N R M
2C -2
SUPPLY CLO
2C-2111
HAC
2C-2102B
ACCUMULATION
2C-2102A
DENTAL X-RAY
2C-2102
EXAM RM
2C-2105
DENTAL LAB
2C-2106
EXAM RM
2C-2107
EXAM RM
2C-2107A
STORAGE
2C-2106A
EXAM RM
2E-2105
READING
2E-2108 EXAM RM
2E-2109
EXAM RM
2E-2110
EXAM RM
2E-2111
NEUROLOGY CLINIC
2E-2112
STORAGE
2E-2167
EYE CLINIC OFFICE
2E-2166A
EY
E C
LI
N
IC
E
XA
M R M
2E -2
EY
E C
LI
N
IC
E
XA
M R M
2E -2
U R O
LO
G Y
EX
A M R M
2E -2
SOILED UTILITY
2E-2163
GU CLINIC EXAM RM
2E-2160
WAITING UROLOGY
2E-2162
STAFF LOCKER
2E-2159
CORRIDOR
2E-2051
C O R R
ID
O R
2E -2
CAST RM
2E-2153
CORRIDOR
2E-2048
PODIATRY EXAM RM
2E-2158
PODIATRY EXAM RM
2E-2152
PODIATRY EXAM RM
2E-2151
STAFF TOILET
2E-2157
EXAM RM
2E-2103
EXAM RM
2E-2104
TOILET
2E-2113
CORRIDOR
2E-2030
EXAM RM
2E-2115
SP
C
LI
N
IC
O
FF
IC
E
2E -2
EXAM RM
2E-2144
EXAM RM
2E-2145
PATIENTS TOILET
2E-2150
SUPPLY
2E-2146
DERMATOLOGY
OFFICE
2E-2143
SHOWER
2E-2144A
EXAM RM
2E-2136E
EXAM RM
2E-2136D
ST
O R A G E
2E -2
6CWORK AREA
CORRIDOR
2E-2045
TOILET
2E-2136B
C O R R
ID
O R
DERMATOLOGY
2E-2136
EXAM RM
2E-2136A
STAIR#2
CORRIDOR
2E-2043
C O R R
ID
O R
2E -2
CONFERENCE RM
2E-2134
EXAM RM
2E-2133
EXAM RM
2E-2132
EXAM RM
2E-2131
EXAM RM
2E-2139
C O M M U N
IC
A
TI
O N
2E -2
WAITING
2E-2040
CORRIDOR
2E-2038
WAITING
2E-2037
C O R R
ID
O R
2E -2
WAITING
2E-2128
BREAK RM
2E-2148 OFFICE
2E-2147
SP CLINIC EXAM RM
2E-2140
SP CLINIC EXAM RM
2E-2141
EXAM RM
2E-2142
EL
EC
TR
IC
A L
2E -2
CORRIDOR
2E-2052
CORRIDOR
2E-2046
C O R R
ID
O R
2E -2
PATIENTS TOILET
2E-2156
PATIENTS TOILET
2E-2155
ST
A
FF
T O
IL
ET
2E -2
OFFICE
2E-2149
N MGR OFFICE
2E-2126
WAITING
2E-2035
RECEPTION
2E-2036
CLINIC
2E-2130
EXAM RM
2E-2129
ROOM
2E-2169
VASCULAR LAB
2E-2168
GU/NURSING CLINIC
EXAM RM
2E-2161
C O R R
ID
O R
2E -2
GU/UROLOGY
CYSTOSCOPY RM
2E-2170
CHASE
G A S
ST
O R A G E
2E -2
EXAM RM
2E-2116
CHEST CLINIC
2E-2117
CHEST CLINIC
2E-2118
CLINICAL CO ORDR
OFFICE
2E-2121
NUTRITION CLINIC
2E-2122WAITING
2E-2033
C O R R
ID
O R
2E -2
C O R R
ID
O R
2E -2
COMMUNICATION
CLOSET
2E-2176
ELEV #S1
2E-2014
ELEV #S2
2E-2015
ELEV #P1
2E-2011
ELEV #P2
2E-2012
ELEV #P3
2E-2013
CORRIDOR
2E-2034
PATIENT ELEV LOBBY
2E-2021
SVC ELEV LOBBY
2E-2056
EL
EC
TR
IC
A L
2E -2
ST
A
IR
#3
LINEN
2E-2174
STORAGE
2E-2173
CHUTE
CHUTE
R
ES
P
ST
O R A G E
2E -2
SHAFT
C O R R
ID
O R
2E -2
CHECK-IN
2E-2100
WORK RM
2E-2100A
CHECK-IN
2E-2022
CARDIOLOGY
CONFERENCE RM
2E-2101
EXAM RM
2E-2102
CHIROPRACTOR
2E-2107
EXAM RM
2E-2107A
EXAM RM
2E-2106 CORRIDOR
2E-2032
C O R R
ID
O R
2E -2
ATU
2E-2119A
ATU
2E-2119
ATU
2E-2120
ATU SUPPLY RM
2E-2120A
ELECTRICAL
2E-2123
HAC
2E-2124
C O R R
ID
O R
2E -2
CORRIDOR
2E-2028
CORRIDOR
2E-2024
CORRIDOR
2E-2025
CORRIDOR
2E-2026
W A
IT
IN
G
2E -2
CORRIDOR
2C-C2-1
STAIR#7
MECH EQUIP
2C-277
MECH EQUIP
2E-2135
EYE EXAM
1S-280
EYE EXAM
1S-279
EYE EXAM
1S-277
OPTHALMOLOGIST
OFFICE
1S-278
HAC
1S-276
SPD
1S-270
OCULAR
PHOTOGRAPHY
1S-271
SHOWER
1S-272
EXAM RM
1S-273
EXAM RM
1S-274EYE EXAM
1S-274B
REGISTRATION
1S-268
OFFICE
1S-266
OPTOMETRY EXAM RM
1S-275A
OPTOMETRY EXAM
RMS
1S-275B
PATIENT TOILET
1S-269
EXAM OPTOMETRY
1S-267
PATIENT WAITING RM
1S-264
UTILITY
1S-265
TOILET
1S-2618
EM
PL
O
YE
E
TO
IL
ET
1S -2
EXAM OPTOMETRY
1S-261 OPTOMETRY EXAM
1S-262
TELECOM ROOM
1C-242
LOBBY
1C-241
CORRIDOR
1C-C2-1
ELEV
ELEV
MAIL RM
1C-243
OPTOMETRY OFFICE
1C-246
MECH
MAIL RM OFFICE
1C-245
REPRODUCTION RM
1C-244
C O R R
ID
O R
1S -C 2-
OPTOMETRY OFFICE
SHOP
1S-266A
RECEPT OFFICE
1N-224A
FI
LM
L A B O R A
TO
R Y
1N -2
TOILET FEMALE
1N-225
TOILET MALE
1N-227
BATH RM
PI
PE
C H A
SE
1N -2
OFFICE RADIOLOGIST
RADIOLOGIST
1N-221
OFFICE
1N-219
OFFICE RADIOLOGIST
RADIOLOGIST
1N-217
OFFICE
1N-215
ELECTRICAL
1N-206
EXAM RM
1N-222
TELEPHONE RM
1N-220A
PA
SS
A G E
1N -2
X-RAY RM CHEST RM
1N-209
ST
O R A G E R M
1N -2
MECH
1N-211
X-RAY RM
1N-213
CONTROL RM
IN-213A
TOILET
TOILET
CT SCANNER RM
1N-207
CT SCANNER RM
1N-205
EQUIP CLOSET
1N-208A
PATIENTS TOILET
1N-203
1N-201
X-RAY RM
1N-214
CONTROL RM
1N-216A
FE
M A
LE
L O C K
ER
1N -2
CONFERENCE RM
1N-212A
EMPLOYEE LOUNGE
1N-212
CORRIDOR
1N-C2-5
M A
LE
L O C K
ER
S
1N -2
DARK RM
1N-206
C O R R
ID
O R
1N -C 2-
D R
ES
SI
N G R M
1N -2
ULTRASOUND RM
1N-202
STAIR#2
EXAM RM
1S-281
STAIR #1
TELECOM ROOM
2E-2149
ELEV
#S3
LOBBY
2C-C2-13
CORRIDOR
C2-14
01E-401 C7
01E-401 F7
02E-405 C3
02E-405 F3
02E-401 D1
02E-401 F1
07/03/2024
07/03/2024
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
CONSULTANT
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
2W
TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202
MAT PERKINS
(315) 484-5958
2C 2E
STAMP
Au to de sk
D oc s:
//6
A4
-2 2-
0_
N ew in gt on _V
AM
C
_E H
R M
_I U
-1
2/
9A 4-
-7
.N ew in gt on
.E H
R M
.M
EP
.B
_0 2_
R
.rv t
-1
0-
6:
:3
E-102
ELECTRICAL PLAN - OVERALL BUILDING FLOOR
PLAN - SECOND LEVEL
689A4-22-700
01_02
07/03/2024 M. Perkins J. Schooley
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
555 Willard Avenue, Newington, CT 06111
SCALE: 1" = 20'-0"F3
ELECTRICAL PLAN - OVERALL
BUILDING FLOOR PLAN - SECOND
LEVEL
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING
WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL
PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION
WHERE FEASIBLE. CONSTRUCTION AREA CONDITIONS MAY DIFFER FROM
THOSE INDICATED.
MINIMUM BRANCH CIRCUIT SIZE SHALL BE 2#12, 1#12G., 3/4"C.
CONTRACTOR SHALL COORDINATE FINAL POINT OF CONNECTIONS
WITH VA COR PRIOR TO ROUGH-IN.
PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT INSTALLED
OUTDOORS
SIZE BRANCH CIRCUITS AND FEEDERS TO EQUIPMENT PER PANEL
SCHEDULE AND FEEDER AND BRANCH CIRCUIT SIZING TABLE ON E-701.
COORDINATE FINAL EQUIPMENT CONNECTIONS AT EQUIPMENT WITH
EQUIPMENT SUPPLIER, PRIOR TO ROUGH-IN.
LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL LISTING
PANEL AND CIRCUIT FEEDING THE WIRING DEVICE.
UPDATE PANEL SCHEDULES AFFECTED BY RENOVATION.
NEW CIRCUIT BREAKERS PROVIDED SHALL MATCH THE EXISTING TYPE
AND AIC RATING OF CIRCUIT BREAKERS IN PANEL BEING RENOVATED.
CONTRACTOR SHALL FIELD COORDINATE CABLE TRAY LAYOUT WITH
EXISTING UTILITIES ROUTED THROUGH THE RENOVATED SPACE.
CONTRACTOR SHALL COMPLY WITH NEC 300.22 FOR CONDUIT ROUTED IN
PLENUM SPACES.
REFER TO E-901 FOR CUTSHEETS.
COMPLY WITH NEC 220.87 FOR ALL 30-DAY LOAD MEASUREMENTS OF
PANELBOARDS.
LOCATE DISCONNECT SWITCHES TO MAINTAIN WORKING CLEARANCES
PER NEC 110.26.
CONTRACTOR SHALL LABEL ALL JUNCTION BOX COVERS WITH THE CIRCUITS
EXISTING CONSTRUCTION TO REMAIN
SMOKE AND 1-HR RATED FIRE
BARRIER AND OPENINGS
SMOKE AND 2-HR RATED FIRE BARRIER
AND OPENINGS
SMOKE BARRIER AND OPENINGS
1 HR RATED FIRE BARRIER AND
OPENINGS
2 HR RATED FIRE BARRIER AND OPENINGS
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES
MECH
1-345
MENTAL HEALTH
OFFICE
1-343
DIRECTOR OF HEARING
AND RECOVERY PGM
1-344
MENTAL HEALTH
OFFICE
1-342
MENTAL HEALTH
GROUP RM
1-337
MENTAL HEALTH OT
1-337A
MENTAL HEALTH
THERAPIST
1-336
MENTAL HEALTH
OFFICE
1-335
M
EN
TA
L H
EA
LT
H
N U R
SE
C A
SE
M A N A G E
1-
MENTAL HEALTH
OFFICE
1-333
MENTAL HEALTH
GROUP RM
1-339
STAIR#2
CHASE
TOILET
1-338
TOILET
1-34
ELECTRICAL
1-341
CORRIDOR
1S-C3-12
CORRIDOR
1S-C3-10
WAITING
1-C3-11
CORRIDOR
1S-C3-9
C O R R
ID
O R
1S -C 3-
W/D
1-327A
MENTAL HEALTH
OFFICE
1-327
MENTAL HEALTH DAY
RM AND DINING
1-322
ELEV LOBBY
1C-C3-6
MENTAL HEALTH
OFFICE
1-323
ELEV
ELEV
TELECOM ROOM
1-324
STAIR#1
MENTAL HEALTH
OFFICE
1-321
TOILET
1-320A
MENTAL HEALTH
OFFICE
1-326
MENTAL HEALTH
OFFICE
1-328
MENTAL HEALTH
OFFICE
1-329
MENTAL HEALTH
OFFICE
1-331
MENTAL HEALTH
OFFICE
1-330
MENTAL HEALTH
OFFICE
1-332
MENTAL HEALTH
OFFICE
1-319
MENTAL HEALTH
OFFICE
1-320
MENTAL HEALTH
OFFICE
1-318
MENTAL HEALTH
OFFICE
1-315
MENTAL HEALTH
OFFICE
1-313
MENTAL HEALTH
OFFICE
1-309
MENTAL HEALTH
OFFICE
1-310
MENTAL HEALTH
OFFICE
1-312
STORAGE
1-314
MENTAL HEALTH EXAM
RM
1-316
HAC
1-317
TO
IL
ET
1-
ELECTRICAL
1-310A
COMMUNICATION
1-304A
GROUP RM-B
1-304
RECEPTION MENTAL
HEALTH
1-C3-5
C O R R
ID
O R
1N -C 3-
WAITING RM
1-302
DR OFFICES
1-300
MENTAL HEALTH
OFFICE
1-301
GROUP RM-A
1-303
CHASE
CHASE
ROOM
1N-C3-3
CORRIDOR
1N-C3-4
TOILET RM
1-305
CHASE
DIRECTOR MENTAL
HEALTH
1-306
TOILET
1-306A
COPY RM
1-308
STORAGE RM
1-307A
MENTAL HEALTH
OFFICE
1-307
OFFICE
2C-3132
M
IR
EC
C R
ES
EA
R C H
O
FF
IC
E
2C -3
OFFICE
2C-3134
PS
Y N P R A C
TI
TI
O N
ER
O
FF
IC
E
2C -3
5 OFFICE
2C-3136
STORAGE
2C-3137
O
FF
IC
E
2C -3
PATIENTS TOILET
2C-3138A
STAFF TOILET
2C-3139A
CORRIDOR
2C-C3-8C H A
SE -
PSYCHOLOGY FELLOW
OFFICE
2C-3131
R
EC
R
EA
TI
O N
TH
ER
A
PI
ST
O
FF
IC
E
2C -3
0 OFFICE
2C-3129
STAIR #8
OFFICE
2C-3128
PATIENTS TOILET
2C-3127
OFFICE
2C-3126
EXAMINATION
2C-3125
ELECT
2C-3124
OFFICE
2C-3122
EVALUATION
C3-7
OFFICE
2C-3121
HAC
2C-3120
PSY INTERN OFFICE
2C-3119
GROUP RM-A
2C-3117
TOILET
2C-3117A
TOILET
2C-3116A
SUPPLY
2C-3118
GROUP RM -B
2C-3116
CORRIDOR
2C-3115
PSY RESIDENT
2C-3114
C O
PY
R M
2C -3
DOCTORS CHART
2C-3112
PNEUMATIC TUBE
NURSES STATION
C3-3024
O
FF
IC
E
2C -3 1B
TOILET
2C-3111A
ANTE RM
2C-3111
GROUP RM -C
2C-3110 O
FF
IC
E
2C -3
SOCIAL WORKER
2C-3108
INTERN OFFICE
2C-3107
OFFICE
2C-3106
WOMENS TOILET
2C-3100
PATIENTS TOILET
2C-3101
CLOTHING RM
2C-3102
PSY OFFICE
2C-3103
TOILET
2C-3104
MED DIRECTOR OFFICE
2C-3105
STAIR
C3-2
PATIENT ELEV LOBBY
C3-3022
LOBBY
2C-3021
ELEV
ADMIN OFFICE
2C-3147
OFFICE
2C-3139A
C O R R
ID
O R
2C -C 3-
STAFF LOCKERS AND
LOUNGE
2C-3139
STORAGE
2C-3140
OFFICE
2C-3146A
CONFERENCE RM
2C-3139
COMMUNICATION
2C-3143
STAIR#4
C O R R
ID
O R
2C -C 3-
CLOSET
CORRIDOR
2C-C3-3
ROOM
C O R R
ID
O R
2E -3
C O M M U N
IC
A
TI
O N
C
LO
SE
T
2E -3
ELEV #P1
2E-3011
ELEV #P2
2E-3012
ELEV #P3
2E-3013
ELEV #S1
2E-3014
ELEV #S2
2E-3015
STAIR#3
EL
EC
T
2E -3
CHUTE
CHUTE
STORAGE
2E-3155
VBA OFFICE
2E-3154
CHASE
COMPUTER TRAINING
RM
2E-3137
M
IL
IT
A R Y O R D
ER
O F
PU
R
PL
E H
EA
R T O
FF
IC
E
2E -3
OFFICE
2E-3136A
NATIONAL SVC
OFFICER
2E-3133A
MENS RM
2E-3135
WOMENS RM
2E-3134
SECY/WAITING
2E-3133
AMERICAN LEGION
OFFICE
2E-3132
OFFICE
2E-3132A
OFFICE
2E-3132B
UNION OFFICE
2E-3129A
UNION OFFICE
2E-3129
SECY AREA
2E-3128
NATIONAL SVC
OFFICER
2E-3128A
N A
TI
O N A L
SV
C
O
FF
IC
ER
2E -3 7A
BREAK RM
2E-3126
CT DVA OFFICE
2E-3127
SHAFT
CORRIDOR
2E-3029
LOCATING RM
2E-3125
FIRM 3 SHARED TOILET
2E-3124A
MHICM RANGE PGM
SUPV OFFICE
2E-3124
MHICM RANGE PGM
TEAM OFFICE
2E-3120
STORAGE/TOILET
2E-3119A
VOLUNTARY OFFICE
2E-3119
VO
LU
N
TA
R Y
ST
O R A G E
2E -3
A
SS
T C H
IE
F
VO
LU
N
TA
R Y O
FF
IC
E
2E -3
STORAGE
2E-3117A
COPY RM VOLUNTARY
2E-3116
TOILET
2E-3115A
VOLUNTARY OFFICE
(SECRETARY)
2E-3115
K
IT
C H
EN
V O
LU
N
TA
R Y
2E -3
H A C
2E -3
ROOM
2E-3102A
PT
2E-3102B
SVC ELEV LOBBY
2E-3039
CORRIDOR
2E-3037 SHAFT
H A C
2E -3
STORAGE
2E-3110
UNION OFFICE
2E-3111
C O R R
ID
O R
2E -3
COMPUTER TRAINING
RM
2E-3112
TELECOM ROOM
2E-3113A
CHASE
STORAGE
2E-3114
RESTROOM
2E-3122
OFFFICE
2E-3131
C O M M
2E -3
ELECT
2E-3130
STAIR#2
C O R R
ID
O R
2E -3
CORRIDOR
2E-3027
CORRIDOR
2E-3026
C O R R
ID
O R
2E -3
PT
S
TO
R A G E
2E -3 5C
ELECT
2E-3106
PT TREATMENT RM
2E-3101B
WAITING
2E-3105
PT TREATMENT RM
2E-3105A
MULTIPURPOSE
CENTER
2E-3101
REHAB MEDICINE
2E-3102
OT SKILLS
2E-3101
PT OFFICE
2E-3101D
PT OFFICE
2E-3101C
CONFERENCE RM
2E-3100
PATIENT ELEV LOBBY
2E-3021
C O R R
ID
O R
2E -3
MENS TOILET
2E-3103
WOMENS TOILET
2E-3104
RECEPTION
2E-3100A
C O R R
ID
O R
2E -3
STAIR#6
CORRIDOR
2E-3032
CORRIDOR
2E-3035
TOILET
2E-3107
OFFICE
2E-3128B
ELEV
NATIONAL SVC
OFFICER
2E-3127B
TELECOM ROOM
2C-3140A
01E-401 C5
01E-401 F5
02E-405 C1
02E-405 F1
02E-402 C7
02E-402 F7
07/03/2024
07/03/2024
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
CONSULTANT
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
2W
TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202
MAT PERKINS
(315) 484-5958
2C 2E
STAMP
Au to de sk
D oc s:
//6
A4
-2 2-
0_
N ew in gt on _V
AM
C
_E H
R M
_I U
-1
2/
9A 4-
-7
.N ew in gt on
.E H
R M
.M
EP
.B
_0 2_
R
.rv t
-1
0-
6:
:4
E-103
ELECTRICAL PLAN - OVERALL BUILDING FLOOR
PLAN - THIRD LEVEL
689A4-22-700
01_02
07/03/2024 M. Perkins J. Schooley
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
555 Willard Avenue, Newington, CT 06111
SCALE: 1" = 20'-0"F4
ELECTRICAL PLAN - OVERALL
BUILDING FLOOR PLAN - THIRD LEVEL
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING
WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL
PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION
WHERE FEASIBLE. CONSTRUCTION AREA CONDITIONS MAY DIFFER FROM
THOSE INDICATED.
MINIMUM BRANCH CIRCUIT SIZE SHALL BE 2#12, 1#12G., 3/4"C.
CONTRACTOR SHALL COORDINATE FINAL POINT OF CONNECTIONS
WITH VA COR PRIOR TO ROUGH-IN.
PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT INSTALLED
OUTDOORS
SIZE BRANCH CIRCUITS AND FEEDERS TO EQUIPMENT PER PANEL
SCHEDULE AND FEEDER AND BRANCH CIRCUIT SIZING TABLE ON E-701.
COORDINATE FINAL EQUIPMENT CONNECTIONS AT EQUIPMENT WITH
EQUIPMENT SUPPLIER, PRIOR TO ROUGH-IN.
LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL LISTING
PANEL AND CIRCUIT FEEDING THE WIRING DEVICE.
UPDATE PANEL SCHEDULES AFFECTED BY RENOVATION.
NEW CIRCUIT BREAKERS PROVIDED SHALL MATCH THE EXISTING TYPE
AND AIC RATING OF CIRCUIT BREAKERS IN PANEL BEING RENOVATED.
CONTRACTOR SHALL FIELD COORDINATE CABLE TRAY LAYOUT WITH
EXISTING UTILITIES ROUTED THROUGH THE RENOVATED SPACE.
CONTRACTOR SHALL COMPLY WITH NEC 300.22 FOR CONDUIT ROUTED IN
PLENUM SPACES.
REFER TO E-901 FOR CUTSHEETS.
COMPLY WITH NEC 220.87 FOR ALL 30-DAY LOAD MEASUREMENTS OF
PANELBOARDS.
LOCATE DISCONNECT SWITCHES TO MAINTAIN WORKING CLEARANCES
PER NEC 110.26.
CONTRACTOR SHALL LABEL ALL JUNCTION BOX COVERS WITH THE CIRCUITS
EXISTING CONSTRUCTION TO REMAIN
SMOKE AND 1-HR RATED FIRE
BARRIER AND OPENINGS
SMOKE AND 2-HR RATED FIRE BARRIER
AND OPENINGS
SMOKE BARRIER AND OPENINGS
1 HR RATED FIRE BARRIER AND
OPENINGS
2 HR RATED FIRE BARRIER AND OPENINGS
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES
ROOM
E43
VBA STORAGE
1-401
VBA STORAGE
1-403
HAC
1-404
OPEN OFFICE
1-405
1-406
COMMUNICATION
1-407
PO
LI
C E
ST
O R A G E
1-
EQUIP STORAGE
1-409
UTILITY
1-410
VBA STORAGE
1-411
C
LE
A N / S
TE
R
IL
E
SU
PP
LI
ES
1-
ELECTRICAL
1-413
POLICE LOCKER
1-414
VBA STORAGE
1-415
POLICE LOCKER
1-416
ROOM
1-417
TOILET
1-416A
ACUPUNCTURE CLINIC
1-419
ROOM
1-420
ELEV LOBBY
1C-C4-7
STAIR #1
4-ST-1
HOME BASE HEALTH
CARE
1-423
MENS TOILET
1-425
ROOM
1-426
FEMALE TOILET
1-427
SUICIDE PREVENTION
1-429
VISUAL IMPAIRMENT
SVC
1-428
ROOM
1-430 C O R R
ID
O R
1C -C 4- A
STAIR #2
4-ST-2
C O R R
ID
O R
1C -C 4-
STORAGE
1-434
CONFERENCE ROOM
1-438
MECH
1-446
CONFERENCE
1-445
ELECTRICAL
1-444
TOILET
1-414A
SCRUB
1-411D
WOMEN SHOWER
1-411BFEMALE SHOWER
1-410A
CORRIDOR
1N-C4-4
CORRIDOR
1N-C4-3
ELEV
E1
ELEV
E2
C H A
SE -
CHASE
INTERVIEW
2E-4102
PUBLIC CONTACT
2E-4106D
PUBLIC CONTACT
2E-4106E
PUBLIC CONTACT
2E-4106F
PUBLIC CONTACT
2E-4106A
PUBLIC CONTACT
2E-4106B
PUBLIC CONTACT
2E-4106C
FILE RM
2E-4105
FSER
2E-4107E
FSER
2E-4107D
FSER
2E-4107F
FSER
2E-4107G
FSER
2E-4107H
FSER
2E-4107C
FSER
2E-4107B
FSER
2E-4107A
APPEALIS
2E-4108B
APPEALIS
2E-4108A
APPEALIS
2E-4108DA
PP
EA
LI
S
2E -4
COACH OFFICE
2E-4109
COACH OFFICE
2E-4110
CHASE
LOCKED FILES RM
2E-4114
WORK RM
2E-4128
C O N
FE
R
EN
C E R M
2E -4
LOUNGE
2E-4111
C O
PI
ER
A R
EA
2E -4
STAIR #3
4-ST-3
RATING TEAM
2E-4123E
RATING TEAM
2E-4123A
RATING TEAM
2E-4123F
RATING TEAM
2E-4123B
RATING TEAM
2E-4123G
RATING TEAM
2E-4123C
RATING TEAM
2E-4123H
RATING TEAM
2E-4123D
RATING TEAM
2E-4122D
RATING TEAM
2E-4122A
RATING TEAM
2E-4122B
RATING TEAM
2E-4122E
RATING TEAM
2E-4122F
RATING TEAM
2E-4122C
PD TEAM
2E-4121A
PD TEAM
2E-4121B
PD TEAM
2E-4121C
PD TEAM
2E-4121D
PD TEAM
2E-4121H
PD TEAM
2E-4121G
PD TEAM
2E-4121F
PD TEAM
2E-4121E
TFCT
2E-412OE
TFCT
2E-4120A
TFCT
2E-4120F
TFCT
2E-4120B
TFCT
2E-4120G
TFCT
2E-4120C
TFCT
E95
TFCT
2E-4120H
OFFICE
2E-4147
CHASE
E96
STORAGE
2E-4148
CHUTE
CHUTE
ELECTRICAL
2E-4150
C O M M U N
IC
A
TI
O N
C
LO
SE
T
2E -4
ELEV #S1
2E-4014
ELEV #S2
2E-4015
ELEV #P1
2E-4011
ELEV #P2
2E-4012
ELEV #P13
2E-4013
CORRIDOR
2E-4035
JA
N
IT
O R C
LO
SE
T
2E -4
SECURITY
2E-4100D
CHASE
C H A
SE -
INTERVIEW
2E-4103
M A
LE
T O
IL
ET
2E -4 5A
CORRIDOR
2E-4025
WAITING AREA
2E-4100
RECEPTION AREA
E101
ENTRY
2E-4100
WOMENS TOILET
2E-4100C
MENS TOILET
2E-4100B
ANTE RM
2E-4100A
CLOSET
2E-4104
FILE AREA
2E-4115
C H A
SE -
MENS TOILET
2E-4114
COMMUNICATION
2E-4113
WOMENS TOILET
2E-4130
ELECTRICAL
2E-4129
PD TEAM
2E-4124E
PD TEAM
2E-4124A
PD TEAM
2E-4124F
PD TEAM
2E-4124B
PD TEAM
2E-4124C
PD TEAM
2E-4124G
PD TEAM
2E-4124H
PD TEAM
2E-4124D
PD TEAM
2E-4124
RATING TEAM
2E-4123
CHASE
OFFICE
2E-4115
MALE TOILET
2E-4108A
READING RM
2E-4151
C O R R
ID
O R
2E -4
PATIENT ELEVATOR
LOBBY CORRIDOR
2E-4021
SVC ELEVATOR LOBBY
CORRIDOR
2E-4036
CHASE
ST
A
IR
4-
ST
-4
FILE SECTION AND
EDUCATION REP
2E-4107
CORRIDOR
2E-4026
PU
B
LI
C C O N
TA
C T
2E -4
COACH OFFICE
2E-4125
MGR
2E-4126
CORRIDOR
2E-4031
TF
C T
2E -4
C H A
SE -
RATING TEAM
2E-4122
CORRIDOR
2E-4028
MECH
2E-446 C O R R
ID
O R
2E -4
APPEALIS
2E-4108C
APPEALIS
2E-4108E
TELECOM ROOM
2E-4115B
02E-402 C4
02E-402 F4
TELECOM ROOM
1-424
OFFICE
1-401
OFFICE
1-400
01E-401 F3
01E-401 C3
07/03/2024
07/03/2024
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
CONSULTANT
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
2W
TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202
MAT PERKINS
(315) 484-5958
2C 2E
STAMP
Au to de sk
D oc s:
//6
A4
-2 2-
0_
N ew in gt on _V
AM
C
_E H
R M
_I U
-1
2/
9A 4-
-7
.N ew in gt on
.E H
R M
.M
EP
.B
_0 2_
R
.rv t
-1
0-
6:
:4
E-104
ELECTRICAL PLAN - OVERALL BUILDING FLOOR
PLAN - FOURTH LEVEL
689A4-22-700
01_02
07/03/2024 M. Perkins J. Schooley
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
555 Willard Avenue, Newington, CT 06111
SCALE: 1" = 20'-0"F4
ELECTRICAL PLAN - OVERALL
BUILDING FLOOR PLAN - FOURTH
LEVEL
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING
WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL
PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION
WHERE FEASIBLE. CONSTRUCTION AREA CONDITIONS MAY DIFFER FROM
THOSE INDICATED.
MINIMUM BRANCH CIRCUIT SIZE SHALL BE 2#12, 1#12G., 3/4"C.
CONTRACTOR SHALL COORDINATE FINAL POINT OF CONNECTIONS
WITH VA COR PRIOR TO ROUGH-IN.
PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT INSTALLED
OUTDOORS
SIZE BRANCH CIRCUITS AND FEEDERS TO EQUIPMENT PER PANEL
SCHEDULE AND FEEDER AND BRANCH CIRCUIT SIZING TABLE ON E-701.
COORDINATE FINAL EQUIPMENT CONNECTIONS AT EQUIPMENT WITH
EQUIPMENT SUPPLIER, PRIOR TO ROUGH-IN.
LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL LISTING
PANEL AND CIRCUIT FEEDING THE WIRING DEVICE.
UPDATE PANEL SCHEDULES AFFECTED BY RENOVATION.
NEW CIRCUIT BREAKERS PROVIDED SHALL MATCH THE EXISTING TYPE
AND AIC RATING OF CIRCUIT BREAKERS IN PANEL BEING RENOVATED.
CONTRACTOR SHALL FIELD COORDINATE CABLE TRAY LAYOUT WITH
EXISTING UTILITIES ROUTED THROUGH THE RENOVATED SPACE.
CONTRACTOR SHALL COMPLY WITH NEC 300.22 FOR CONDUIT ROUTED IN
PLENUM SPACES.
REFER TO E-901 FOR CUTSHEETS.
COMPLY WITH NEC 220.87 FOR ALL 30-DAY LOAD MEASUREMENTS OF
PANELBOARDS.
LOCATE DISCONNECT SWITCHES TO MAINTAIN WORKING CLEARANCES
PER NEC 110.26.
CONTRACTOR SHALL LABEL ALL JUNCTION BOX COVERS WITH THE CIRCUITS
EXISTING CONSTRUCTION TO REMAIN
SMOKE AND 1-HR RATED FIRE
BARRIER AND OPENINGS
SMOKE AND 2-HR RATED FIRE BARRIER
AND OPENINGS
SMOKE BARRIER AND OPENINGS
1 HR RATED FIRE BARRIER AND
OPENINGS
2 HR RATED FIRE BARRIER AND OPENINGS
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES
UTILITY RM
2E-5152
HR SPECIALIST
1-500
BUSINESS OFFICE
1-501
HUMAN RESOURCES
1-502
STORAGE/ BREAK
ROOM
1-503
TELEMENTAL HEALTH
PSYCHOLOGIST
1-504
TELEMENTAL HEALTH
PSYCHOLOGIST
1-505
CALL CENTER
1-506
CALL CENTER
1-507
W O M
EN
S
TO
IL
ET
1-
MENS TOILET
1-509
ROOM
1-510
C O R R
ID
O R
1N -C 5-
ELECTRICAL
1-512
CALL CENTER
1-513
NURSE MANAGER
1-514
OFFICE
1-515
OFFICE
1-516
QUALITY MGMT
1-517
OFFICE
1-518
OFFICE
1-519
FILE ROOM
1-520
REGIONAL COUNCIL
1-521
BREAK ROOM
1-522
EDUCATION
1-523
TELECOM ROOM
1-524
SWING SPACE
1-525
OFFICE
1-526
TOM COORD INFECT
CONT
1-527
ADMIN. ASST
1-528
WOMENS TOILET
1-529
MENS TOILET
1-530
CONFERENCE ROOM
1-531
SITE MGR
1-532
DIRECTOR
1-533
EXECUTIVE
ADMINISTATION
OFFICE
1-534
ELECTRICAL
1-535
KITCHEN
1-506
OFFICE
1-537
OFFICE
1-538
OFFICE
1-539
MECH
1-540
C O R R
ID
O R
1S -C 5-
C O R R
ID
O R
1S -C 5-
KITCHENETTE
1S-C5-10
SECY/ WAITING
1S-C5-8
CORRIDOR
1S-C5-9
C O R R
ID
O R
1S -C 5-
ELEV LOBBY
1C-C5-4
OPEN OFFICE
1C-C5-5
SECY/ WAITING
1C-C5-6
STAIR #1
5ST-1
CALL CENTER
1-513B
WAITING
1N-C5-2
CALL CENTER LEAD
MGR
1-512
CALL CENTER NURSE
1-513A
ELEV
EL
EV -
STAIR #3
5-ST-3
CLOSET
1-C5-12A
TOILET
1-532
C O M M U N
IC
A
TI
O N
C
LO
SE
T
2E -5
ELEV #S1
2E-5014
ELEV #S2
2E-5015
ELEV#P3
2E-5013
ELEV#P2
2E-5012
ELEV#P1
2E-5011
LOBBY
2E-5036
C O R R
ID
O R
2E -5
EL
EC
T
2E -5
STORAGE
2E-5148
CHUTE
CHUTE
OFFICE
2E-5147
CHASE
OFFICE
2E-5135
WORK RM
2E-5135A
W O R K
ST
A
TI
O N
2E -5
3 SPECIAL PROJECTS
RM
2E-5132
LOCKER
2E-5139A
WOMENS TOILET
2E-5139
MENS TOILET
2E-5140
CORRIDOR
2E-5033
CHASE
E174
JANITOR CLOSET
2E-5145
MAIL RM
2E-5137
COMPUTER RM
2E-5138
C O R R
ID
O R
2E -5
COMPUTER RM
2E-5141
PRE-ACTION CLOSET
2E-5154
FILE RM
2E…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .