About this file

36C26118R0487 15 - ELECTRICAL.pdf

View the file

Other files

File Type Posted
36C26118R0487-0005000.docx DOCX document
36C26118R0487-0004000.docx DOCX document
36C26118R0487-0003001.pdf PDF
36C26118R0487-0003000.docx DOCX document
36C26118R0487-0002045.pdf PDF
36C26118R0487-0002037.pdf PDF
36C26118R0487-0002042.pdf PDF
36C26118R0487-0002039.pdf PDF
36C26118R0487-0002043.pdf PDF
36C26118R0487-0002040.pdf PDF
36C26118R0487-0002049.pdf PDF
36C26118R0487-0002048.pdf PDF
36C26118R0487-0002050.pdf PDF
36C26118R0487-0002044.pdf PDF
36C26118R0487-0002046.pdf PDF
36C26118R0487-0002041.pdf PDF
36C26118R0487-0002047.pdf PDF
36C26118R0487-0002038.pdf PDF
36C26118R0487-0002036.docx DOCX document
36C26118R0487-0001001.pdf PDF
36C26118R0487-0001000.docx DOCX document
36C26118R0487-0001003.pdf PDF
36C26118R0487-0001002.pdf PDF
36C26118R0487-101.pdf PDF
36C26118R0487-093.pdf PDF
36C26118R0487-096.pdf PDF
36C26118R0487-099.pdf PDF
36C26118R0487-109.pdf PDF
36C26118R0487-107.pdf PDF
36C26118R0487-090.pdf PDF
36C26118R0487-106.pdf PDF
36C26118R0487-094.pdf PDF
36C26118R0487-104.pdf PDF
36C26118R0487-089.docx DOCX document
36C26118R0487-100.pdf PDF
36C26118R0487-102.pdf PDF
36C26118R0487-108.pdf PDF
36C26118R0487-098.pdf PDF
36C26118R0487-105.pdf PDF
36C26118R0487-092.xls XLS spreadsheet
36C26118R0487-091.doc DOC document
36C26118R0487-097.pdf PDF
36C26118R0487-095.pdf PDF
36C26118R0487-103.pdf PDF
36C26118R0487-000.docx DOCX document
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R

EX

A

X a

WALL

CEILING

WALL

CEILING

OS

OS

208Y/120V T1A 75kVA K-4

E4E3

A

DRAWING NUMBER WHERE TAKEN

DRAWING NUMBER WHERE DETAILED

SECTION/ELEVATION LETTER OR DETAIL

NUMBER

A

E4

E4

+44"

DRAWING NUMBER WHERE DETAILED

SECTION/ELEVATION LETTER OR DETAIL

NUMBER

VAV-9

(NOT ALL SYMBOLS APPLY TO THIS PROJECT)

NORTH ARROW OR MATCH ARCHITECT'S

SCALE BAR OR MATCH ARCHITECT'S

SURFACE

WALL

CEILING

ONE-LINE DIAGRAM

SPD

3000/5

CIRCUIT BREAKER; TRIP SETTING/FRAME SIZE OR NO. OF POLES.

SETTINGS AND PROTECTION AS NOTED ON PLANS

DRAWOUT CIRCUIT BREAKER

MEDIUM VOLTAGE DRAWOUT

CIRCUIT BREAKER

POTENTIAL TRANSFORMER.

DISCONNECT SWITCH. "300A"

DENOTES AMPERAGE RATING

FUSE. "300A" DENOTES AMPERAGE

RATING

GROUND CONNECTION

TRANSFER SWITCH. SEE PLANS

FOR TYPE OF SWITCH

SURGE ARRESTOR

SURGE PROTECTIVE DEVICE

KILOWATT METER

ELECTRONIC METER

KIRK KEY INTERLOCK No.1

RELAY No.1

AMMETER SWITCH

AMMETER

VOLTMETER SWITCH

VOLTMETER

DELTA CONNECTED

WYE CONNECTED

LIGHTING

RECESSED MOUNTED LUMINAIRE. SMALL CASE

"a" DENOTES SWITCHING, NUMBER "3" DENOTES

BRANCH CIRCUITING. SYMBOL "A" DENOTES

LUMINAIRE TYPE

WALL MOUNTED LUMINAIRES

STRIP LUMINAIRE

LINEAR DIRECT/INDIRECT LUMINAIRE. CABLE

OR STEM MOUNTED

DOWN LIGHT LUMINAIRE; CEILING MOUNTED

EXIT LUMINAIRE. SHADED SIDE INDICATES

FACE SIDE. PROVIDE DIRECTIONAL ARROW(S)

AS INDICATED ON PLANS

EMERGENCY BATTERY PACK LUMINAIRE

(BUG-EYE/FROG-EYE)

DOUBLE HEAD, POLE MOUNTED LUMINAIRE

TRACK MOUNTED LUMINAIRES

SURFACE

AS

DETAILED

CEILING

EXTERIOR

WALL

DEMOLITION

DASHED SYMBOL INDICATES EXISTING

DEVICE OR EQUIPMENT TO BE REMOVED

SOLID SYMBOL, LIGHTER IN COLOR

INDICATES EXISTING DEVICE OR EQUIPMENT

TO REMAIN

EXISTING CONDUIT TO BE REUSED

REMOVE EXISTING RACEWAY IN ALL ACCESSIBLE

AREAS. CAPPED AND ABANDONED IF IN

UNACCESSIBLE AREA

SYMBOL DEFINITION

REFERENCE TAGS

KEYED NOTE REFERENCE

MECHANICAL EQUIPMENT REFERENCE

DENOTES MOUNTING HEIGHT AFF

KITCHEN EQUIPMENT REFERENCE

MEDICAL EQUIPMENT REFERENCE

GENERAL DRAWING SYMBOLS

TRIP SETTING

FRAME SIZE

VARIES

R E

F E

R T

O L

IG

H

T

IN

G S

C H

E D

U

LE

EMERGENCY, CRITICALEC

EMERGENCY, LIFE SAFETYEL

EMERGENCY, EQUIPMENTEQ

TELEVISIONTV

EXISTING(E)

GROUND FAULT PROTECTIONGFP

SWITCHSW

FEEDERFDR

UNDERGROUND ELECTRICUGE

MANHOLEMH

MIXED MEDIAMM

UNDERGROUNDU/G

POWER MONITORING AND CONTROL SYSTEMPMCS

AUTOMATIC TRANSFER SWITCH CONTROLATSC

TEMPORARYTEMP

SECURITYSEC

DEFINITIONABBREV.

ABBREVIATIONS

A

ADA

AFF

AFG

AWG

ANSI

AIC

C

CCTV

CLF

CO

GFI

GND

HOA

G OR GFCI

FACP

AMPS, AMPERE, AMPERAGE

ABOVE FINISHED GRADE

ABOVE FINISHED FLOOR

AMERICANS WITH DISABILITIES ACT

AVAILABLE INTERRUPTING CURRENT

AMERICAN NATIONAL STANDARDS INSTITUTE

GROUND FAULT CIRCUIT INTERRUPTER

HAND-OFF-AUTOMATIC.

GROUND.

GROUND FAULT INTERRUPTER

CURRENT LIMITING FUSE

AMERICAN WIRE GAUGE

CLOSED CIRCUIT TELEVISION

FIRE ALARM CONTROL PANEL

CONDUIT ONLY

CONDUIT

HP

IEEE

KV

KVA

KW

KWH

MVA

MCC

NEC

NEMA

NIC

NFPA

NM

P

PA

PC

NC

POLE

KILOVOLT AMPS

NATIONAL FIRE PROTECTION ASSOCIATION

PHOTOCELL

PUBLIC ADDRESS

NEW MEXICO

NOT IN CONTRACT

NATIONAL ELECTRICAL CODE

NATIONAL ELECTRICAL MANUFACTURERS

MOTOR CONTROL CENTER

MEGAVOLT AMPS

NORMALLY CLOSED

KILOWATT HOUR.

KILOWATT

HORSEPOWER

KILOVOLT

TVSS

UPS

UON

V

VFD

XFER

XFMR (TRANSF)

VARIABLE FREQUENCY DRIVE

UNINTERRUPTABLE POWER SUPPLY

TRANSIENT VOLTAGE SURGE SUPPRESSER

TRANSFORMER

TRANSFER

UNLESS OTHERWISE NOTED

VOLTS, VOLTAGE

TTB TELEPHONE TERMINAL BOARD

INSTITUTE OF ELECTRICAL AND ELECTRONICS

CEILING MOUNTED OCCUPANCY SENSOR; TYPE

AS INDICATED ON PLANS

DISTRIBUTION POLE FOR OVERHEAD ELECTRICAL OR

COMMUNICATIONS AS INDICATED ON PLAN.

OVERHEAD UTILITY AND OR SYSTEM DISTRIBUTION.X

X

3PH = THREE PHASE

X X

UT UTILITY OR FACILITY TRANSFORMER

S

CC

PAD MOUNTED SWITCH

CONNECTION CABINET (UTILITY

METER MOUNT)

MH

MANHOLE - POWER OR COMMUNICATION

AS INDICATED ON PLANS

HH HAND HOLE - POWER OR COMMUNICATION

AS INDICATED ON PLANS

1PH = SINGLE PHASE

S = ELECTRICAL SECONDARY

P = ELECTRICAL PRIMARY

T = TELECOMMUNICATION

TV = TELEVISION

E = EMERGENCY POWER

ATSC = AUTOMATIC TRANSFER SWITCH CONTROL

PM PRIMARY SITE METER ENCLOSURE

EG ENGINE GENERATOR

TP TELECOMMUNICATION PEDESTAL

TVP TELEVISION PEDESTAL

METER ENCLOSURE. EITHER ON BUILDING OR ON UTILITY

EQUIPMENTME

CT CT ENCLOSURE. EITHER ON BUILDING OR ON UTILITY EQUIPMENT

GENERATOR

a =

2 = 3 = 4 = P = M = K =

WP =

T =

D =

AC ABOVE COUNTER

AL ALUMINUM

ATS AUTOMATIC TRANSFER SWITCH

CKT CIRCUIT

CU COPPER

DL DAY-LIGHTING

DIA DIAMETER

FA FIRE ALARM

KCMIL THOUSAND CIRCULAR MILS

MAX MAXIMUM

MIN MINIMUM

NEUT NEUTRAL

PH PHASE

RSC RIGID STEEL CONDUIT

UC UNDER COUNTER

WP WEATHERPROOF

WALL MOUNTED OCCUPANCY SENSOR; TYPE

AS INDICATED ON PLANS

HATCHING INDICATES EMERGENCY LIGHTING.

HATCH WILL BE MODIFIED FOR EACH

LUMINAIRE TYPE. EMERGENCY LUMINAIRE

DESIGNATED WITH "E" IN TYPE DESIGNATION.

VARIES

SURFACE MOUNTED LUMINAIRE.

LUMINAIRE TYPE AS INDICATED ON PLANS

REFER TO

DEMOLITION

PLANS FOR

ADDITIONAL

INFORMATION

(F) FUTURE

LSIG LONG TIME, SHORT TIME, INSTANTANEOUS,

(N) NEW

W WALL MOUNTED

NL NORMAL

MTS MANUAL TRANSFER SWITCH

UL UNDERWRITERS' LABORATORIES

EMERGENCYE

IG ISOLATED GROUND

KVAR KILOVOLT AMPS REACTIVE

NO NORMALLY OPEN

SURGE PROTECTIVE DEVICESPD

REFER TO LUMINAIRE SCHEDULE FOR ALL LUMINAIRE TYPES WHETHER WALL MOUNTED

OR CEILING MOUNTED.

GROUND FAULT PROTECTION

SHUNT TRIP OPERATOR

TYP. TYPICAL

TRIP SETTING

FRAME SIZE

300A

300A

N/A NOT APPLICABLE

O/H OVERHEAD

GEN GENERATOR

ENGINE GENERATOREG

SYMBOL DESCRIPTION MOUNTING

HT.LOC.

SINGLE HEAD, POLE MOUNTED LUMINAIRE

DOUBLE FACE EXIT LUMINAIRE. SHADED SIDE

INDICATES FACE SIDE. PROVIDE DIRECTIONAL

ARROW(S) AS INDICATED ON PLANS

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION NOTES

ASSOCIATION

AND GROUND FAULT PROTECTION

ENGINEERS

UTILITIES

DESCRIPTIONSYMBOL

NORTH

ELECTRICAL SYMBOL LEGEND

E3 E4

TRANSFORMER. TRANSFORMER NAME, TRANSFORMER kVA RATING, PRIMARY VOLTAGE AND WIRING CONFIGURATION, SECONDARY

VOLTAGE, K RATING (IF APPLICABLE)

G

ST

0 10' 20' 40' 80'

1" = 40'-0"

DEVICE INDICATOR LETTER. "X" EQUALS

DESIGNATION BELOW

(TYPICAL FOR MOST SWITCH TYPES):

SMALL CASE LETTER DENOTES SWITCHING

CONTROL

DOUBLE POLE TOGGLE SWITCH

THREE-WAY TOGGLE SWITCH

FOUR-WAY TOGGLE SWITCH

PILOT LIGHT TOGGLE SWITCH

MOMENTARY CONTACT SWITCH

KEY OPERATED SWITCH

WEATHERPROOF TOGGLE SWITCH

MANUAL MOTOR STARTER SWITCH WITH

THERMAL OVERLOAD PROTECTION

DIMMER SWITCH

KW

M

K1

R1

AS

A

VS

V

VFD CONNECTION

MOTOR CONNECTION

UPS

VFD

J

T

30/3R

0/1

1/30/3R

F

30/1

30/3R

DEVICES

CODE SIZE JUNCTION BOX

WALL MOUNTED CODE SIZE J-BOX

CODE SIZE PULLBOX (OR AS SIZED ON PLAN)

ENCLOSED CIRCUIT BREAKER.

AMPERAGE/NEMA ENCLOSURE RATING, 3 POLE

UON

NON-FUSED DISCONNECT SWITCH.

AMPERAGE/NEMA ENCLOSURE RATING, 3 POLE

UON

FUSED DISCONNECT SWITCH.

AMPERAGE/NEMA ENCLOSURE RATING, 3 POLE

UON

MOTOR STARTER. STARTER SIZE INDICATED

BY NUMBER/NEMA ENCLOSURE RATING,

SINGLE SPEED UON

COMBINATION FUSIBLE DISCONNECT SWITCH

AND MOTOR STARTER. NEMA STARTER

SIZE/AMPERAGE/NEMA ENCLOSURE RATING, 3

POLE UON

MOTOR. NUMBER INDICATES HORSEPOWER

RATING FOR 1HP AND LARGER

THERMOSTAT

PHOTOCELL

LIGHTNING PROTECTION AIR TERMINAL

PUSHBUTTON (EMERGENCY POWER OFF - EPO)

SYMBOL DESCRIPTION MOUNTING

+44"

UON

N/A

VARIES

HT.LOC.

WALL

ROOF

VARIES

N/A

VARIES

MULTI-OULET ASSEMBLY (SURFACE MOUNTED

RACEWAY) VARIES

SEE

PLANS

VARIES

SEE

PLANS

MOTOR. "F" INDICATES FRACTIONAL

HORSEPOWER

VARIES

SEE

PLANS

VARIES

SEE

PLANS

VARIES

DEVICE INDICATOR LETTER. "X" EQUALS DESIGNATION BELOW

(TYPICAL FOR MOST RECEPTACLE TYPES):

BLANK FOR NORMAL POWER

G = GFCI RATED

IG = ISOLATED GROUND

T = TAMPERPROOF

WG = WEATHERPROOF AND GFCI

WP = WEATHERPROOF (IN-USE COVER)

CL = CLOCK

TV = TELEVISION

+18", UON

FLUSH

IN FLOOR DUPLEX RECEPTACLE.

CONFIGURATION AS INDICATED ON PLANS

IN FLOOR DOUBLE DUPLEX (QUADPLEX)

RECEPTACLE. CONFIGURATION AS INDICATED ON

PLANS

CEILING MOUNTED DUPLEX RECEPTACLE

CEILING MOUNTED DOUBLE DUPLEX

(QUADPLEX) RECEPTACLE

SIMPLEX RECEPTACLE

DUPLEX RECEPTACLE

DOUBLE DUPLEX (QUADPLEX) RECEPTACLE

EMERGENCY DOUBLE DUPLEX (QUADPLEX)

RECEPTACLE

SPECIAL PURPOSE RECEPTACLE. NEMA

CONFIGURATION AND AMPERAGE AS NOTED ON

PLANS

COMBINATION POWER/COMMUNICATION POLE.

CONFIGURATION AS NOTED ON PLANS

FLOOR

CEILING

WALL,

UON

IN FLOOR EMERGENCY DUPLEX RECEPTACLE.

CONFIGURATION AS INDICATED ON PLANS

CEILING MOUNTED EMERGENCY DUPLEX

RECEPTACLE

EMERGENCY DUPLEX RECEPTACLE

COMBINATION POWER/COMMUNICATION IN

CEILING OUTLET. CONFIGURATION AS

INDICATED ON PLANS

COMBINATION DUPLEX RECEPTACLE AND

COMMUNICATIONS FLOORBOX. DEVICE

CONFIGURATION AS INDICATED ON PLANS.

X

X

X

X

X

X

X

X

X

X

X

X

X

X

J

P

IN FLOOR EMERGENCY DOUBLE DUPLEX

(QUADPLEX) RECEPTACLE. CONFIGURATION AS

INDICATED ON PLANS

X

A, B, C, = SEQUENCE OF PANELS OF THIS TYPE

1, 2, 3, . . = SUBFED PANEL

1, 2, 3, . . = FLOOR LEVEL

H L

T

BLANK FOR NORMAL POWER

EL

EC

EQ

= EMERGENCY-LIFE SAFETY-BRANCH

= EMERGENCY-CRITICAL-BRANCH

= EMERGENCY-EQUIPMENT-BRANCH

GROUND BAR

MAIN SWITCHBOARD. DASHED LINES INDICATE CLEARANCES.

VARIABLE FREQUENCY DRIVE

SYMBOL

EQUIPMENT

DESCRIPTION

EQUIPMENT NAMING CONVENTION

= HIGH VOLTAGE PANELBOARD (480Y/277V)

= LOW VOLTAGE PANELBOARD (208Y/120V)

= TRANSFORMER

= DISTRIBUTION BOARDDB

= MAIN SWITCH BOARDMSB

MCC= MOTOR CONTROL CENTER

= UNINTERRUPTABLE POWER SUPPLYUPS

= POWER DISTRIBUTION UNIT

ATS = AUTOMATIC TRANSFER SWITCH

PDU

= ISOLATED PANELBOARDI

B = BUSWAY

MSB

FLUSH MOUNTED PANELBOARD. DASHED LINES INDICATE CLEARANCES.

SURFACE MOUNTED PANELBOARD. DASHED LINES INDICATE

CLEARANCES.

H1A

L1A

MCC

MOTOR CONTROL CENTER. DASHED LINES INDICATE CLEARANCES.

T1A

UNINTERRUPTABLE POWER SUPPLY. DASHED LINES INDICATE

CLEARANCES.

AUTOMATIC TRANSFER SWITCH. DASHED LINES INDICATE CLEARANCES.

DRY TYPE TRANSFORMER (15kVA OR ABOVE), WITH EQUIPMENT TAG

(TAG INSIDE OR OUTSIDE, DEPENDING ON SIZE). IN MOST CASES,

ACTUAL SIZE SHOWN ON PLANS (ELECTRICAL ROOMS).

E = EMERGENCY

DISTRIBUTION BOARD. DASHED LINES INDICATE CLEARANCES.

DB

UPS-A

ATS-1

EXAMPLES:

A. SES1 (SERVICE ENTRANCE SECTION #1)

B. 1H1A (SERVED FROM SES#1, 480/277 NORMAL, LEVEL 1, FIRST BOARD)

C. 1EQH1A (SERVED FROM MAIN EMER SWBD #1, 480/277 EQUIP POWER, LEVEL 1,

FIRST BOARD)

SES

G

= GROUND

= HOT/PHASE

= NEUTRAL

= SWITCH LEG

CONDUCTOR IDENTIFICATION SYMBOLS. REFER TO

PLANS FOR COMBINATION USE. CONDUCTOR

IDENTIFICATION MOSTLY USED IN HOMERUN

LOCATION, BUT CAN ALSO BE USED IN BRANCH

CIRCUITING WHERE APPLIED. GROUND

CONDUCTORS WILL BE INSTALLED IN ALL RACEWAYS

WHETHER SHOWN OR NOT.

LA-1

HOMERUN FROM EQUIPMENT LOCATION. THE CIRCUIT

NUMBER ADJACENT TO HOMERUN INDICATES PANEL

SOURCE AND INDIVIDUAL SINGLE POLE CIRCUIT

BREAKER(S). CONDUCTOR IDENTIFICATION SYMBOL

INDICATES NUMBER OF CONDUCTORS IN HOMERUN.

MINIMUM #12 CONDUCTORS AND 3/4" RACEWAY PATH

WILL BE PROVIDED IN HOMERUN UON. ALL HOMERUNS

WILL INCLUDE GROUND CONDUCTOR.

LA-7

HOMERUN FROM EQUIPMENT LOCATION. THE CIRCUIT

NUMBER ADJACENT TO HOMERUN INDICATES PANEL

SOURCE AND INDIVIDUAL TWO OR THREE POLE CIRCUIT

BREAKERS. CONDUCTOR IDENTIFICATION SYMBOL

INDICATES NUMBER OF CONDUCTORS IN HOMERUN.

MINIMUM #12 CONDUCTORS AND 3/4" RACEWAY PATH

WILL BE PROVIDED IN HOMERUN UON. NEUTRAL MAY BE

USED WHERE INDICATED ON PLAN. ALL HOMERUNS WILL

INCLUDE GROUND CONDUCTOR.

LA-13

CONCEALED RACEWAY BETWEEN DEVICES AND OR

EQUIPMENT IN WALLS OR IN CEILING SPACE

UNDERGROUND RACEWAY BETWEEN DEVICES AND

OR EQUIPMENT

EXPOSED RACEWAY BETWEEN DEVICES AND OR

EQUIPMENT ON WALLS OR CEILINGS

CONDUIT TURNS

DOWN UP

B BUSWAY

GROUNDING CONDUCTORG

CABLE TRAY - POWER AND TELECOMMUNICATIONS

T TELECOMMUNICATIONS RACEWAY

D DATA RACEWAY

FA FIRE ALARM RACEWAY

CONDUIT STUBBED AND CAPPED

VOICE/DATA COMBINATION RACEWAYV/D

BRANCH CIRCUIT GENERAL INFORMATION:

BRANCH CIRCUITS FROM OVERCURRENT PROTECTION (20A) TO FURTHEST DEVICE SHALL NOT

EXCEED 75 FEET FOR #12AWG COPPER AND 150 FEET FOR #10AWG COPPER MEASURED ALONG

CONDUCTORS ROUTING PATH. BRANCH CIRCUITS EXCEEDING 150 FEET WILL BE SIZED SO THAT

VOLTAGE DROP DOES NOT EXCEED 5%. 2% FOR FEEDERS AND 3% FOR BRANCH CIRCUITS. REF:

CEC 210.19(A).

LA-1,3

LA-5,7,9

HOMERUN FROM EQUIPMENT LOCATION. THE CIRCUIT

NUMBER ADJACENT TO HOMERUN INDICATES PANEL

SOURCE AND INDIVIDUAL SINGLE POLE CIRCUIT

BREAKER(S). SYMBOL REPRESENTS A MULTI-BRANCH

CIRCUIT. NUMBER OF CONDUCTORS IN HOMERUN WILL

INCLUDE A SEPERATE NEUTRAL FOR EACH CIRCUIT PHASE

CONDUCTOR. MINIMUM #12 CONDUCTORS AND 3/4"

RACEWAY PATH WILL BE PROVIDED IN HOMERUN UON.

ALL HOMERUNS WILL INCLUDE GROUND CONDUCTOR.

RACEWAY & CONDUCTORS

CURRENT TRANFORMER, NUMBER

"3000/5" DENOTES RATIO.

WG WEATHERPROOF AND GFCI

R REMOVED/REMOVAL

RC ROOM CONTROLLER

FAA FIRE ALARM ANNUNCIATOR

FMS FACILITY MANAGEMENT SYSTEM

GROUND FAULT EQUIPMENT PROTECTIONGFEP

CB CIRCUIT BREAKER

D DIMMING

DC DIRECT CURRENT

UPS

NUMBER OR MAIN EMERG SWBD NUMBER

= SERVICE ENTRANCE SECTION

(SB=SUB-BASEMENT, B=BASEMENT, M=MEZZANINE,

P=PENTHOUSE)

CEILING MOUNTED EMERGENCY DOUBLE

DUPLEX (QUADPLEX) RECEPTACLEX

PC

UNDERGROUND UTILITY AND OR SYSTEM DISTRIBUTION.

X

X

N = NEW

EX = EXISTING

DL DAY-LIGHTING SENSOR; TYPE AS INDICATED

ON PLANS

RC ROOM CONTROLLER; TYPE AS INDICATED

ON PLANS

480V

CL CLOCK

CB

FATC FIRE ALARM TERMINAL CABINET

UPDATED: 03/03/2014

A/V AUDIO/VISUAL

DRY TYPE TRANSFORMER (LESS THAN 15kVA), WITH NO EQUIPMENT TAG.

SIZE, TYPE AND LOCATION NOTED ON PLANS.

A/C ALTERNATING CURRENT

DESCRIPTIONSYMBOL

T

VFD

FC FOOTCANDLES

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in ch o ne fo o t o n e-h al f i n ch o n e fo o t th re e-qu ar te rs in ch o ne fo o t

6" o n e in ch o n e fo o t o n e an d o ne -h al f i n ch o ne fo o t th re e in ch es o ne fo o t

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

PROJECT TEAM ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

ISSUED FOR CONSTRUCTION

TRIPLE C - THE A-E GROUP

4401 ATLANTIC AVE. SUITE 200

LONG BEACH, CA 90807

CONTACT: DAVID POTTER

PHONE: 307 460-2054

SUBMISSION

BRIDGERS & PAXTON CONSULTING ENGINEERS, INC.

1839 S. ALMA SCHOOL ROAD, SUITE 300

MESA, AZ 85210

CONTACT: JOHN MONTANO

PHONE: 602 336-5415

UNITED STRUCTURAL DESIGN, LLC

720 W. COMMERCE AVE OR P.O. BOX 33245

GILBERT, AZ 85233 PHOENIX, AZ 85067

CONTACT: DAVID GRAPSAS

PHONE: 480 382-9768

2-2-18

BIM

0:/ /57

0-1 6-3

VA

Fr es no C hil ler

Pl an t P 2 1

6/V

A F res no C hil ler

Pl an t E lec

.rv t

2/5 /20

5:

:43

PM

E-001

ELECTRICAL LEGEND

J. MONTANO R. RIBA02/02/2018

570-16-302PHASE 2 CHILLER

INFRASTRUCTURE ON FRESNO

CAMPUS

100% CONSTRUCTION DOCUMENTS

2615 E Clinton Ave, Fresno, CA 93703

CONTRACTOR IS TO PROVIDE NEW CONTROLS, LIGHTS AND OUTLETS AS IDENTIFIED IN THE

DRAWINGS AND SPECIFICATIONS. ALL LIGHTING TO BE 5-7 FC ALONG WALKWAY. COORDINATE ALL SHUTDOWNS WITH THE COR 30 DAYS IN ADVANCE AND AGAIN 2 DAYS IN ADVANCE TO ENSURE ALL

SAFETY PRECAUTIONS ARE IN PLACE AND OPERATIONAL IMPACTS ARE MINIMIZED. NIGHT AND

WEEKEND WORK WILL BE REQUIRED FOR THIS CONTRACT.

ELECTRICAL SCOPE OF WORK:

GENERAL

CONTRACTOR SHALL INFORM HIMSELF OF ANY ELECTRICAL INFORMATION THAT

MIGHT BE SHOWN IN OTHER DISCIPLINES OF THIS PROJECT AND NOT SHOWN IN

ELECTRICAL DIVISION. COORDINATE ALL WORK DISCREPANCIES WITH ARCHITECT

PRIOR TO BID. SHOULD COORDINATION NOT OCCUR, IT IS UNDERSTOOD THAT THE

CONTRACTOR FOUND NO DISCREPANCIES AND SHALL PROVIDE AND INSTALL

ELECTRICAL RACEWAY, CONDUCTORS, DEVICES, AND EQUIPMENT AT NO

ADDITIONAL COST TO THE OWNER.

THE CONTRACTOR SHALL REFER TO DIVISION 26 SPECIFICATIONS FOR ADDITIONAL

INFORMATION AND REQUIREMENTS. THE SPECIFICATIONS ARE A PART OF THE

CONSTRUCTION DOCUMENT SET AND MAY CONTAIN INFORMATION NOT SHOWN ON

THE DRAWING SET.

THESE DRAWINGS REFLECT INFORMATION ON EXISTING BUILDING SERVICES

GATHERED BY SITE INSPECTION AND PREVIOUS CONSTRUCTION DRAWINGS. THE

EXACT LOCATION, ARRANGEMENT, AND SIZES OF EXISTING DEVICES MAY BE

DIFFERENT FROM THAT SHOWN ON THESE DRAWINGS. ALL BIDDERS ARE

REQUIRED TO INVESTIGATE EXISTING BUILDING CONDITIONS PRIOR TO

SUBMITTING THEIR BIDS AND PROVIDE ALL REQUIRED FILED MEASUREMENTS

PRIOR TO ORDERING OF NEW COMPONENTS AND DEVICES.

THE WORD "PROVIDE" SHALL MEAN TO FURNISH AND INSTALL. EXCEPTIONS SHALL

BE NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS.

DO NOT SCALE THE ELECTRICAL DRAWING TO DETERMINE THE LOCATIONS OF

LUMINAIRIES, OUTLETS, OR EQUIPMENT. REFER TO THE ARCHITECTURAL

DRAWINGS AND FIELD MEASUREMENTS FOR ALL PROJECT DIMENSIONS.

THE CONTRACTOR SHALL COORDINATE THE SHUTDOWN OF EXISTING BUILDING

SERVICES FOR REMOVALS WITH OWNER AUTHORIZED REPRESENTATIVE AND

SHALL CONFORM TO THEIR REQUIREMENTS.

THE CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER DISCIPLINES

PRIOR TO START OF WORK AND INSTALLATION OF EQUIPMENT.

ALL EXPOSED CONDUIT, FITTING, BOXES, HANGERS, CLIPS, SUPPORTS, ETC. IN

FINISHED AREAS SHALL BE PAINTED PER THE ENGINEERS INSTRUCTIONS.

ALL DEVICES, RACEWAY, CONDUCTORS AND LUMINAIRES ARE EXISTING AND SHALL

REMAIN UNLESS INDICATED BOLDLY OR OTHERWISE INDICATED BY KEYED NOTE.

IN THE CASE OF CONFLICTS NOT CLARIFIED PRIOR TO THE BIDDING DEADLINE, USE

THE MOST COSTLY ALTERNATIVE (BETTER QUALITY, GREATER QUANTITY, AND

LARGER SIZE) IN PREPARING THE BID.

CONTRACTORS SHALL VERIFY AND COORDINATE WITH EXACT MOUNTING HEIGHTS

AND LOCATIONS OF ALL DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN. ALL

RACEWAYS FOR RECEPTACLES TO RUN CONCEALED BENEATH COUNTER AS

REQUIRED.

ALL GROUNDING CABLE IN THE WHOLE ELECTRICAL DISTRIBUTION SYSTEM SHALL

SHOW ZERO CURRENT (AFTER THE SYSTEM IS ENERGIZED) - IF ANY CURRENT IS

FOUND IN THE SYSTEM, THEN THE CONTRACTOR IS RESPONSIBLE TO RESOLVE

THE PROBLEM AND REMOVE OBJECTIONABLE CURRENT FROM THE GROUNDING

SYSTEM.

CIRCUITS

REFER TO GROUNDING DIAGRAM FOR GROUNDING INFORMATION.

ALL TERMINATIONS AT EQUIPMENT SHALL BE RATED AT 75 C MINIMUM. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

LIGHTING

THE LUMAIRE DESCRIPTION SHALL TAKE PRECEDENCE OVER A LUMINAIRE

MANUFACTURER MODEL NUMBER SHOULD A CONFLICT OCCUR.

EQUIPMENT

REFER TO MECHANICAL DRAWINGS FOR CONTROL DIAGRAMS AND/OR SEQUENCE

OF OPERATION DESCRIPTIONS.

REFER TO MECHANICAL DRAWINGS FOR EQUIPMENT SCHEDULES.

SWITCHES CONTROLLING MECHANICAL EQUIPMENT SHALL BE LABELED FOR THE

EQUIPMENT SERVED.

SIZE ALL FUSES PER THE EQUIPMENT MANUFACTURERS RECOMMENDATION.

PROVIDE FEEDERS BETWEEN THE VFD AND MECHANICAL EQUIPMENT SIZED PER

THE HOMERUN.

PROVIDE FEEDERS BETWEEN THE STARTERS AND DISCONNECT SWITCHES SIZED

PER THE HOMERUN.

THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL AND

PLUMBING DRAWINGS FOR EXACT LOCATION OF EQUIPMENT CONNECTIONS.

ALL NEW BREAKERS SHALL BE RATED WITH AN AIC RATING OF THE EXISTING

PANELBOARD IN WHICH THEY WILL BE INSTALLED IN ACCORDANCE WITH NEC

110.3(B) AND 110.9.

A

A.01

A.02

A.03

A.04

A.05

A.06

A.07

A.08

A.09

A.10

A.11

A.12

B

B.01

B.02

C

C.01

D

D.01

D.02

D.03

D.04

D.05

D.06

D.07

D.08

GENERAL NOTES

NO REVISIONS DATE

A

B

C

D

E

W

X

7.9

EPP

EP - 26

(E)(E)

BUILDING 22

BUILDING 31

BUILDING 22A

ADD ALTERNATE

SEE SHEET ES101.5B

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C8lE

(E)

EP - 40

ELECTRICAL

ROOM

BLl

C2lE

BLl

BLl BLl

BLl

LCP

BLlBLl

BLl BLl

35 35 BLl BLl BLl BLl

BLlBLlBLlBLlBLlBLl

BLl

35 35 35 35 35 40

403535353535

BLl

BLl

BLl

BLl

BLl

BLl

A

B

C

D

E

W

X

7.9

EPP

(E)

EP - 25

L1Sl

L1Sl

L1Sl L1Sl

L1SlL1Sl

L1Sl

L1Sl

L1SlL1Sl L1SlL1Sl L1Sl

ADD ALTERNATE

SEE SHEET ES101.5A

BUILDING 22

BUILDING 31

BUILDING 22A

L1SlL1SlL1SlL1Sl L1Sl

181818

18 18 18 18

P - 18

L1Sl

ZL

ZL ZL

ZL ZL ZL

ZL ZL

ZL

ZL

ZLZLZLZLZL

ZLZLZLZL

ZL18

L1Sl

ELECTRICAL

ROOM

(E) (E)

LCP

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in ch o ne fo o t o n e-h al f i n ch o n e fo o t th re e-qu ar te rs in ch o ne fo o t

6" o n e in ch o n e fo o t o n e an d o ne -h al f i n ch o ne fo o t th re e in ch es o ne fo o t

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

PROJECT TEAM ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

ISSUED FOR CONSTRUCTION

TRIPLE C - THE A-E GROUP

4401 ATLANTIC AVE. SUITE 200

LONG BEACH, CA 90807

CONTACT: DAVID POTTER

PHONE: 307 460-2054

SUBMISSION

BRIDGERS & PAXTON CONSULTING ENGINEERS, INC.

1839 S. ALMA SCHOOL ROAD, SUITE 300

MESA, AZ 85210

CONTACT: JOHN MONTANO

PHONE: 602 336-5415

UNITED STRUCTURAL DESIGN, LLC

720 W. COMMERCE AVE OR P.O. BOX 33245

GILBERT, AZ 85233 PHOENIX, AZ 85067

CONTACT: DAVID GRAPSAS

PHONE: 480 382-9768

2-2-18

BIM

0:/ /57

0-1 6-3

VA

Fr es no C hil ler

Pl an t P 2 1

6/V

A F res no C hil ler

Pl an t E lec

.rv t

2/5 /20

5:

:54

PM

ES101.1

ELECTRICAL PATHWAY ACCENT AND CANOPY

LIGHTING SITE PLANS - PHASE 1

J. MONTANO R. RIBA02/02/2018

570-16-302PHASE 2 CHILLER

INFRASTRUCTURE ON FRESNO

CAMPUS

100% CONSTRUCTION DOCUMENTS

2615 E Clinton Ave, Fresno, CA 93703

GENERAL SHEET NOTES

KEYNOTES

A. REFER TO SHEET E-001 FOR GENERAL NOTES.

0' 5' 10' 20'

SCALE: 1" = 10'-0"2 ELECTRICAL CANOPY LIGHTING SITE PLAN - PHASE 1

NO

RT

H

FR

ES

NO

S

TR

EE

T

EAST HARVARD AVENUE

NO

RT

H

AN

GU

S

ST

RE

ET

EAST CLINTON AVENUE

TANK

O2

TANK

O2

KEY PLAN

B31

B3 B32

P1 B24

B25

B2

B22A

B1

OPC

B27

B34

B3

B19& B19A

1. PROVIDE RECESSED LINEAR LUMINAIRE WITH FLANGE (N). COORDINATE WITH

ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO SHEET E-701 FOR

ADDITIONAL INFORMATION.

2. PROVIDE RECESSED DOWNLIGHT (N). COORDINATE WITH ARCHITECT FOR EXACT

LOCATION PRIOR TO ROUGH-IN. REFER TO SHEET E-701 FOR ADDITIONAL

INFORMATION.

3. PROVIDE GFCI RATED RECEPTACLE WITH "EXTRA DUTY" IN-USE WEATHERPROOF

METAL COVER (N). COORDINATE WITH ARCHITECT FOR EXACT LOCATION PRIOR TO

ROUGH-IN.

4. REFER TO SHEET EP101 FOR ADDITIONAL INFORMATION IN THIS AREA.

5. PROVIDE LED ROPE LIGHT (N) UNDER COLUMN. COORDINATE WITH ARCHITECT FOR

EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO SHEETS E-701 AND A-502 FOR

ADDITIONAL INFORMATION.

6. PROVIDE LED TAPE LUMINAIRE (N). MOUNT ON MIDDLE HSS STRUCTURAL FRAMING.

COORDINATE WITH ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN. REFER

TO SHEETS E-701, M-501 AND A-501 FOR ADDITIONAL INFORMATION.

7. PROVIDE PUSHBUTTON DOOR SWITCH (N) FOR LED TAPE LUMINAIRE. COORDINATE

WITH ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN.

8. ROUTE CIRCUIT THROUGH NEXT SPARE CONTACT ON LIGHTING CONTROL PANEL

(LCP). SET TO "DUSK TO DAWN" UNLESS REQUIRED OTHERWISE BY OWNER.

(TYP.)

(TYP.)

(TYP.)4

SCALE: 1" = 10'-0"1 ELECTRICAL PATHWAY ACCENT LIGHTING SITE PLAN - PHASE 1 0' 5' 10' 20'

(TYP.)

(TYP. FOR ALL DOORS)

(TYP.)

D

E

W

X

4344454647

Z

W.0

40.9

X.0

42.8

Y

B22.4

3.10

3.11

3.12

7.9

42.1

B22.4

B22.3

B22.2

P H

A S

E

S E

E S

H E

E T

E S

1.

P H

A S

E

S E

E S

H E

E T

E S

1.

BUILDING 3

BUILDING 36

BUILDING 24

C8lE

C8lE

ADD ALTERNATE

SEE SHEET ES101.5B

C8lE

C8lE

C8lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

26 26

26 26

26 26

26262626

26 26

C8lE

C8lE C8lE

C8lE

C8lE

C8lE

C8lE

C8lEC8lEC8lE

C8lE

C8lE

C2lE C2lE

C2lEC2lEC2lEC2lE

C2lE C2lE C2lE

C2lE

28 28 28

C2lE

C2lE

EP - 28

C2lE

C2lE

EP - 37

EP - 39

EP - 5

BLl BLl BLl

BLlBLlBLl

5 5 5

BLl BLl BLl BLl BLl BLl

BLlBLlBLlBLlBLlBLl

39 39 39 39 39 39

393939393939

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

D

E

W

X

4344454647

Z

W.0

40.9

X.0

42.8

Y

B22.4

3.10

3.11

3.12

7.9

42.1

B22.4

B22.3

B22.2

P H

A S

E

S E

E S

H E

E T

E S

1.

P H

A S

E

S E

E S

H E

E T

E S

1.

BUILDING 3

BUILDING 36

BUILDING 24

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl 20

20L1SlL1Sl L1Sl

2020 20

SLl20

20 20 20 20SLl SLl SLl SLl SLl

SLl

ZLZL

ZL ZL

272727

ZL

ZL

ZL

ZL

ZL

ZL

ZLZLZL ZL ZL ZL ZL

L1Sl L1Sl L1Sl L1Sl

L1SlL1Sl

EP - 27

SLl

P - 20

ADD ALTERNATE

SEE SHEET ES101.5A

ZL

ZL

L1Sl

L1Sl

L1Sl

20 SLl

ZL

20 20

TO

CENTRAL

PLANT

TO CLC

TO B27

T-8 B25

T-9 B24

MH-NP1

(MH6)

MH-NP2

(MH7)

EX

EX

EX

EX EX

X

X

X

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in ch o ne fo o t o n e-h al f i n ch o n e fo o t th re e-qu ar te rs in ch o ne fo o t

6" o n e in ch o n e fo o t o n e an d o ne -h al f i n ch o ne fo o t th re e in ch es o ne fo o t

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

PROJECT TEAM ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

ISSUED FOR CONSTRUCTION

TRIPLE C - THE A-E GROUP

4401 ATLANTIC AVE. SUITE 200

LONG BEACH, CA 90807

CONTACT: DAVID POTTER

PHONE: 307 460-2054

SUBMISSION

BRIDGERS & PAXTON CONSULTING ENGINEERS, INC.

1839 S. ALMA SCHOOL ROAD, SUITE 300

MESA, AZ 85210

CONTACT: JOHN MONTANO

PHONE: 602 336-5415

UNITED STRUCTURAL DESIGN, LLC

720 W. COMMERCE AVE OR P.O. BOX 33245

GILBERT, AZ 85233 PHOENIX, AZ 85067

CONTACT: DAVID GRAPSAS

PHONE: 480 382-9768

2-2-18

BIM

0:/ /57

0-1 6-3

VA

Fr es no C hil ler

Pl an t P 2 1

6/V

A F res no C hil ler

Pl an t E lec

.rv t

2/5 /20

5:

:58

PM

ES101.2

ELECTRICAL PATHWAY ACCENT AND CANOPY

LIGHTING SITE PLANS - PHASE 2

J. MONTANO R. RIBA02/02/2018

570-16-302PHASE 2 CHILLER

INFRASTRUCTURE ON FRESNO

CAMPUS

100% CONSTRUCTION DOCUMENTS

2615 E Clinton Ave, Fresno, CA 93703

SCALE: 1" = 10'-0"2 ELECTRICAL CANOPY LIGHTING SITE PLAN - PHASE 2 0' 5' 10' 20'

GENERAL SHEET NOTES

KEYNOTES

A. REFER TO SHEET E-001 FOR GENERAL NOTES.

1. PROVIDE RECESSED STEPLIGHT (N). COORDINATE WITH ARCHITECT FOR

EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO SHEET E-701 FOR

ADDITIONAL INFORMATION.

2. PROVIDE RECESSED LINEAR LUMINAIRE WITH FLANGE (N). COORDINATE

WITH ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO

SHEET E-701 FOR ADDITIONAL INFORMATION.

3. PROVIDE RECESSED DOWNLIGHT (N). COORDINATE WITH ARCHITECT FOR

EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO SHEET E-701 FOR

ADDITIONAL INFORMATION.

4. PROVIDE GFCI RATED RECEPTACLE WITH "EXTRA DUTY" IN-USE

WEATHERPROOF METAL COVER (N). COORDINATE WITH ARCHITECT FOR

EXACT LOCATION PRIOR TO ROUGH-IN.

5. PROVIDE LED ROPE LIGHT (N) UNDER COLUMN. COORDINATE WITH

ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO

SHEETS E-701, A-502, AND A-503 FOR ADDITIONAL INFORMATION.PROVIDE

LED STRIP LINEAR LUMINAIRE (N). COORDINATE WITH ARCHITECT FOR

EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO SHEETS E-701 AND

A-501 FOR ADDITIONAL INFORMATION.

6. PROVIDE LED TAPE LUMINAIRE (N). MOUNT ON MIDDLE HSS STRUCTURAL

FRAMING. COORDINATE WITH ARCHITECT FOR EXACT LOCATION PRIOR TO

ROUGH-IN. REFER TO SHEETS E-701, M-501 AND A-501 FOR ADDITIONAL

INFORMATION.

7. PROVIDE PUSHBUTTON DOOR SWITCH (N) FOR LED TAPE LUMINAIRE.

COORDINATE WITH ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-

IN.

8. ROUTE CIRCUIT THROUGH NEXT SPARE CONTACT ON LIGHTING CONTROL

PANEL IN ELECTRICAL ROOM 102. REFER TO SHEET ES101.1 FOR

ADDITIONAL INFORMATION. SET TO "DUSK TO DAWN" UNLESS REQUIRED

OTHERWISE BY OWNER.

9. FUTURE CONSTRUCTION PHASE. REFER TO SHEET AS111.2 FOR

ADDITIONAL INFORMATION.

10. EXISTING MANHOLE LOCATED SOUTH OF BUILDING 3 TO BE REPAIRED.

11. CORE DRILL EXISTING MANHOLE AND PROVIDE NEW 5" SLEEVES FOR

ROUTING NEW CABLES.

12. PROVIDE NEW 15KV CABLE IN CONCRETE ENCASED DUCTBANK. CABLE

SHALL BE INSTALLED PRIOR TO REMOVING EXISTING CABLE. SIZE TO

MATCH EXISTING.

13. EXISTING 15KV CABLE SHALL BE REMOVED AFTER INSTALLATION OF NEW

CABLE.

14. CORE DRILL EXISTING MANHOLE FOR NEW I5KV BYPASS FEEDER FROM

MH-NP1.

15. MANHOLE TO BE REPAIRED.

16. CONTRACTOR TO FIELD VERIFY EXACT ROUTING OF EXISTING PRIMARY

UNDERGROUND ELECTRICAL FEEDS. LOCATION TO BE VERIFIED WITH

NEW COLUMN LOCATIONS.

17. PRIMARY CABLE FROM SITE SWITCHGEAR.

18. CABLE TO MH-NP2 (MH-7).

19. PROPOSED NEW COREDRILL.

20. CABLE TO MH-NP1 (MH-6).

(TYP.)

NO

RT

H

FR

ES

NO

S

TR

EE

T

EAST HARVARD AVENUE

NO

RT

H

AN

GU

S

ST

RE

ET

EAST CLINTON AVENUE

TANK

O2

TANK

O2

KEY PLAN

P2 B31

B3 B32

B24 B25

B2

B22A

B1

OPC

B27

B34

B3

B19& B19A

(TYP.)

2 (TYP.)

(TYP.)

(TYP.)

(TYP.)

SCALE: 1" = 10'-0"1 ELECTRICAL PATHWAY ACCENT LIGHTING SITE PLAN - PHASE 2 0' 5' 10' 20'

(TYP.)

(TYP.) 7

(TYP. FOR ALL DOORS)

MH-NP1 (MH-6)

NTS

MH-NP2 (MH-7)

NTS

TO CLC

TO B22

TO B27

TO B25

TO B24

Z

AA

BB

FF

HH

CC

GG

Y

58.9

58.1

57.5

57.2

49.9

GG.1

FF.1

HH.1DD

58.5

P H

A S

E

S E

E S

H E

E T

E S

1.

BUILDING 3

BUILDING 24

BUILDING 1

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

BLl

BLl

C2lE

EP - 4

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

BLl

C8lE

Z

AA

BB

FF

HH

CC

GG

Y

58.9

58.1

57.5

57.2

49.9

GG.1

FF.1

HH.1DD

58.5

P H

A S

E

S E

E S

H E

E T

E S

1.

BUILDING 3

BUILDING 24

BUILDING 1

L1Sl

L1Sl

SLl

SLl

SLl

SLl

SLl

SLl

SLl

SLl22

SLl

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl

ZL

ZL

ZL

ZL

ZL

ZL

ZL

ZL

ZL

L1Sl

L1Sl

L1Sl

ZL

ZL

SLl

EP - 29

SLl

L1Sl 22

P - 22

L1Sl

L1Sl

22 ZL

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in ch o ne fo o t o n e-h al f i n ch o n e fo o t th re e-qu ar te rs in ch o ne fo o t

6" o n e in ch o n e fo o t o n e an d o ne -h al f i n ch o ne fo o t th re e in ch es o ne fo o t

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

PROJECT TEAM ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

ISSUED FOR CONSTRUCTION

TRIPLE C - THE A-E GROUP

4401 ATLANTIC AVE. SUITE 200

LONG BEACH, CA 90807

CONTACT: DAVID POTTER

PHONE: 307 460-2054

SUBMISSION

BRIDGERS & PAXTON CONSULTING ENGINEERS, INC.

1839 S. ALMA SCHOOL ROAD, SUITE 300

MESA, AZ 85210

CONTACT: JOHN MONTANO

PHONE: 602 336-5415

UNITED STRUCTURAL DESIGN, LLC

720 W. COMMERCE AVE OR P.O. BOX 33245

GILBERT, AZ 85233 PHOENIX, AZ 85067

CONTACT: DAVID GRAPSAS

PHONE: 480 382-9768

2-2-18

BIM

0:/ /57

0-1 6-3

VA

Fr es no C hil ler

Pl an t P 2 1

6/V

A F res no C hil ler

Pl an t E lec

.rv t

2/5 /20

5:

:02

PM

ES101.3

ELECTRICAL PATHWAY ACCENT AND CANOPY

LIGHTING SITE PLANS - PHASE 3

J. MONTANO R. RIBA02/02/2018

570-16-302PHASE 2 CHILLER

INFRASTRUCTURE ON FRESNO

CAMPUS

100% CONSTRUCTION DOCUMENTS

2615 E Clinton Ave, Fresno, CA 93703

GENERAL SHEET NOTES

KEYNOTES

A. REFER TO SHEET E-001 FOR GENERAL NOTES.

SCALE: 1" = 10'-0"2 ELECTRICAL CANOPY LIGHTING SITE PLAN - PHASE 3 0' 5' 10' 20'

(TYP.)

NO

RT

H

FR

ES

NO

S

TR

EE

T

EAST HARVARD AVENUE

NO

RT

H

AN

GU

S

ST

RE

ET

EAST CLINTON AVENUE

TANK

O2

TANK

O2

KEY PLAN

P3 B31

B3 B32

B24 B25

B2

B22A

B1

OPC

B27

B34

B3

B19& B19A

1. PROVIDE RECESSED STEPLIGHT (N). COORDINATE WITH ARCHITECT FOR EXACT

LOCATION PRIOR TO ROUGH-IN. REFER TO SHEET E-701 FOR ADDITIONAL

INFORMATION.

2. PROVIDE RECESSED LINEAR LUMINAIRE WITH FLANGE (N). COORDINATE WITH

ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO SHEET E-701

FOR ADDITIONAL INFORMATION.

3. PROVIDE RECESSED DOWNLIGHT (N). COORDINATE WITH ARCHITECT FOR EXACT

LOCATION PRIOR TO ROUGH-IN. REFER TO SHEET E-701 FOR ADDITIONAL

INFORMATION.

4. PROVIDE GFCI RATED RECEPTACLE WITH "EXTRA-DUTY" IN-USE WEATHERPROOF

METAL COVER (N). COORDINATE WITH ARCHITECT FOR EXACT LOCATION PRIOR

TO ROUGH-IN.

5. EXISTING CONTROL BOARD TO REMAIN.

6. PROVIDE LED ROPE LIGHT (N) UNDER COLUMN. COORDINATE WITH ARCHITECT

FOR EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO SHEETS E-701 AND A-502

FOR ADDITIONAL INFORMATION.

7. PROVIDE LED TAPE LUMINAIRE (N). MOUNT ON MIDDLE HSS STRUCTURAL

FRAMING. COORDINATE WITH ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-

IN. REFER TO SHEETS E-701, M-501 AND A-501 FOR ADDITIONAL INFORMATION.

8. PROVIDE PUSHBUTTON DOOR SWITCH (N) FOR LED TAPE LUMINAIRE.

COORDINATE WITH ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN.

9. ROUTE CIRCUIT THROUGH NEXT SPARE CONTACT ON LIGHTING CONTROL PANEL IN

ELECTRICAL ROOM 102. REFER TO SHEET ES101.1 FOR ADDITIONAL INFORMATION.

SET TO "DUSK TO DAWN" UNLESS REQUIRED OTHERWISE BY OWNER.

(TYP.)

(TYP.)

(TYP.)

SCALE: 1" = 10'-0"1 ELECTRICAL PATHWAY ACCENT LIGHTING SITE PLAN - PHASE 3 0' 5' 10' 20'

(TYP.)

(TYP.)

(TYP. FOR ALL DOORS)

J J J JJJ

J

J

E

F

G

B31.K

B31.L

H

J

L

M

N

P

S

T

89101112

2425262728

Q

R

W

31U

V

37 35 33

K

3.9

7.9

VV UU

WW

XX

PHASE 1

SEE SHEET ES101.1

PHASE 2

SEE SHEET ES101.2

PHASE 3

SEE SHEET ES101.3

L1Sl

L1Sl

24 24

24 24

24 24

24 24

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl

L1Sl

P - 24

EP - 31

ZLZL

ZL

L1SlL1SlL1SlL1Sl L1Sl

ZLZLZL

ZLZLZLZL ZL

ZL

ZL

ZL ZL

ZL

ZL

ZL

ZL

ZL ZL

ZL

ZL

ZL

L1SlL1SlL1Sl L1Sl

24242424

24 24 24 24 24

ZL

ZL

L1Sl

L1Sl

L1Sl

EP - 33

P - 17

P - 19

ZL

ZL

L1Sl

L1Sl

24 24

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in ch o ne fo o t o n e-h al f i n ch o n e fo o t th re e-qu ar te rs in ch o ne fo o t

6" o n e in ch o n e fo o t o n e an d o ne -h al f i n ch o ne fo o t th re e in ch es o ne fo o t

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

PROJECT TEAM ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

ISSUED FOR CONSTRUCTION

TRIPLE C - THE A-E GROUP

4401 ATLANTIC AVE. SUITE 200

LONG BEACH, CA 90807

CONTACT: DAVID POTTER

PHONE: 307 460-2054

SUBMISSION

BRIDGERS & PAXTON CONSULTING ENGINEERS, INC.

1839 S. ALMA SCHOOL ROAD, SUITE 300

MESA, AZ 85210

CONTACT: JOHN MONTANO

PHONE: 602 336-5415

UNITED STRUCTURAL DESIGN, LLC

720 W. COMMERCE AVE OR P.O. BOX 33245

GILBERT, AZ 85233 PHOENIX, AZ 85067

CONTACT: DAVID GRAPSAS

PHONE: 480 382-9768

2-2-18

BIM

0:/ /57

0-1 6-3

VA

Fr es no C hil ler

Pl an t P 2 1

6/V

A F res no C hil ler

Pl an t E lec

.rv t

2/5 /20

5:

:03

PM

ES101.5A

ELECTRICAL PATHWAY ACCENT AND

RECEPTACLE SITE PLAN - ADD ALTERNATE

J. MONTANO R. RIBA02/02/2018

570-16-302PHASE 2 CHILLER

INFRASTRUCTURE ON FRESNO

CAMPUS

100% CONSTRUCTION DOCUMENTS

2615 E Clinton Ave, Fresno, CA 93703

SCALE: 1" = 10'-0"1 ELECTRICAL ACCENT LIGHTING SITE AND RECEPTACLE PLAN - ADD ALTERNATE

GENERAL SHEET NOTES

KEYNOTES

A. REFER TO SHEET E-001 FOR GENERAL NOTES.

1. PROVIDE RECESSED LINEAR LUMINAIRE WITH FLANGE (F). COORDINATE WITH

ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO SHEET E-701 FOR

ADDITIONAL INFORMATION.

2. PROVIDE GFCI RATED RECEPTACLE WITH "EXTRA DUTY" IN-USE WEATHERPROOF

METAL COVER (F). COORDINATE WITH ARCHITECT FOR EXACT LOCATION PRIOR TO

ROUGH-IN.

3. PROVIDE LED ROPE LIGHT (F) UNDER COLUMN. COORDINATE WITH ARCHITECT FOR

EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO SHEETS E-701 AND A-502 FOR

ADDITIONAL INFORMATION.

4. ROUTE CIRCUIT THROUGH NEXT SPARE CONTACT ON LIGHTING CONTROL PANEL IN

ELECTRICAL ROOM 102. REFER TO SHEET ES101.1 FOR ADDITIONAL INFORMATION.

SET TO "DUSK TO DAWN" UNLESS REQUIRED OTHERWISE BY OWNER.

NO

RT

H

FR

ES

NO

S

TR

EE

T

EAST HARVARD AVENUE

NO

RT

H

AN

GU

S

ST

RE

ET

EAST CLINTON AVENUE

TANK

O2

TANK

O2

KEY PLAN

B31

B3 B32

B24 B25

B2

B22A

B1

OPC

B27

B34

B3

B19& B19A

(TYP.)

(TYP.)

(TYP.)

0' 5' 10' 20'

E

F

G

H

J

L

M

N

P

S

T

89101112

2425262728

Q

R

W

31U

V

37 35 33

K

3.9

7.9

VV UU

WW

XX

PHASE 1

SEE SHEET ES101.1

PHASE 2

SEE SHEET ES101.2

PHASE 3

SEE SHEET ES101.3

EP - 30

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lEC2lEC2lEC2lEC2lE

C2lE C2lEC2lEC2lEC2lEC2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lE

C2lEC2lE

C2lE

C2lE

C2lE

C2lE

C2lE C2lE

C2lE

EP - 32

EP - 34

EP - 36

BLlBLl

BLl BLl

BLlBLl

BLl BLl

BLlBLl

BLl BLl

BLl BLl

BLlBLl

BLl BLl

BLlBLl

BLl BLl

BLlBLl

BLl BLl

BLlBLl

BLl BLl

BLlBLl

BLl BLl

BLl

32 32

32 32

32 32

34 34

34 34

34 34

34 34

36 36

36 36

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in ch o ne fo o t o n e-h al f i n ch o n e fo o t th re e-qu ar te rs in ch o ne fo o t

6" o n e in ch o n e fo o t o n e an d o ne -h al f i n ch o ne fo o t th re e in ch es o ne fo o t

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

PROJECT TEAM ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

ISSUED FOR CONSTRUCTION

TRIPLE C - THE A-E GROUP

4401 ATLANTIC AVE. SUITE 200

LONG BEACH, CA 90807

CONTACT: DAVID POTTER

PHONE: 307 460-2054

SUBMISSION

BRIDGERS & PAXTON CONSULTING ENGINEERS, INC.

1839 S. ALMA SCHOOL ROAD, SUITE 300

MESA, AZ 85210

CONTACT: JOHN MONTANO

PHONE: 602 336-5415

UNITED STRUCTURAL DESIGN, LLC

720 W. COMMERCE AVE OR P.O. BOX 33245

GILBERT, AZ 85233 PHOENIX, AZ 85067

CONTACT: DAVID GRAPSAS

PHONE: 480 382-9768

2-2-18

BIM

0:/ /57

0-1 6-3

VA

Fr es no C hil ler

Pl an t P 2 1

6/V

A F res no C hil ler

Pl an t E lec

.rv t

2/5 /20

5:

:11

PM

ES101.5B

ELECTRICAL CANOPY LIGHTING SITE PLAN -

ADD ALTERNATE

J. MONTANO R. RIBA02/02/2018

570-16-302PHASE 2 CHILLER

INFRASTRUCTURE ON FRESNO

CAMPUS

100% CONSTRUCTION DOCUMENTS

2615 E Clinton Ave, Fresno, CA 93703

SCALE: 1" = 10'-0"1 ELECTRICAL CANOPY LIGHTING SITE PLAN - ADD ALTERNATE

GENERAL SHEET NOTES

KEYNOTES

A. REFER TO SHEET E-001 FOR GENERAL NOTES.

1. PROVIDE RECESSED DOWNLIGHT (N). COORDINATE WITH ARCHITECT FOR EXACT

LOCATION PRIOR TO ROUGH-IN. REFER TO SHEET E-701 FOR ADDITIONAL

INFORMATION.

2. PROVIDE LED TAPE LUMINAIRE (N). MOUNT ON MIDDLE HSS STRUCTURAL FRAMING.

COORDINATE WITH ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN. REFER

TO SHEETS E-701, M-501 AND A-501 FOR ADDITIONAL INFORMATION.

3. PROVIDE PUSHBUTTON DOOR SWITCH (N) FOR LED TAPE LUMINAIRE. COORDINATE

WITH ARCHITECT FOR EXACT LOCATION PRIOR TO ROUGH-IN.

4. ROUTE CIRCUIT THROUGH NEXT SPARE CONTACT ON LIGHTING CONTROL PANEL IN

ELECTRICAL ROOM 102. REFER TO SHEET ES101.1 FOR ADDITIONAL INFORMATION.

SET TO "DUSK TO DAWN" UNLESS REQUIRED OTHERWISE BY OWNER.

NO

RT

H

FR

ES

NO

S

TR

EE

T

EAST HARVARD AVENUE

NO

RT

H

AN

GU

S

ST

RE

ET

EAST CLINTON AVENUE

TANK

O2

TANK

O2

KEY PLAN

B31

B3 B32

B24 B25

B2

B22A

B1

OPC

B27

B34

B3

B19& B19A

(TYP.)

(TYP.)

(TYP. ALL DOORS)

0' 5' 10' 20'

EPP

B22.A

B22.4

B22.3

B22.2

B22.B B22.C

(E)(E)

CHILLER 1 (E)

CHILLER 2 (E)

T (E)(E)

ATS (E)

SN-B22 SWBD

(E)

SN-B22 SWBD

(E)

SN-B22 SWBD

(E)

MCC-7 - 1

MCC1-2B - 1

CHILLER 3 (N)

CHILLER 4 (N)

CHWP-1 (E)

CHWP-2 (E)

CHWP-3 (E)

CHP-1 (E)

CHP-2 (E)

CHP-3 (E)

CHP-4 (E)

ELECTRICAL

ROOM

CHILLER PLANT

BLDG 22A

CHILLER PLANT

BLDG 22A

EQUIPMENT

ROOM

CHILLER ROOM

CHILLERS, BLDG

VFD-CWP-1

(N)

VFD-CWP-2

(N)

VFD-CWP-3

(N)

VFD-CWP-4

(N)

LCP

(E)

SUBSTATION(E)

(E)

E-B22 SWBD

MAIN

BREAKER

MCC-7

MCC-7

MCC-7

MCC-6

MCC-6

MCC-6

MCC-E1

MCC-E1

MCC-E1

(E)

MCC-E1

MCC-E1

STACKED

TRANSFORMERS

"EX", "NX"

MCC-E1

MCC-6

PULL BOX

(E)

MCC1-2B

(E)

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in ch o ne fo o t o n e-h al f i n ch o n e fo o t th re e-qu ar te rs in ch o ne fo o t

6" o n e in ch o n e fo o t o n e an d o ne -h al f i n ch o ne fo o t th re e in ch es o ne fo o t

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

PROJECT TEAM ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

ISSUED FOR CONSTRUCTION

TRIPLE C - THE A-E GROUP

4401 ATLANTIC AVE. SUITE 200

LONG BEACH, CA 90807

CONTACT: DAVID POTTER

PHONE: 307 460-2054

SUBMISSION

BRIDGERS & PAXTON CONSULTING ENGINEERS, INC.

1839 S. ALMA SCHOOL ROAD, SUITE 300

MESA, AZ 85210

CONTACT: JOHN MONTANO

PHONE: 602 336-5415

UNITED STRUCTURAL DESIGN, LLC

720 W. COMMERCE AVE OR P.O. BOX 33245

GILBERT, AZ 85233 PHOENIX, AZ 85067

CONTACT: DAVID GRAPSAS

PHONE: 480 382-9768

2-2-18

BIM

0:/ /57

0-1 6-3

VA

Fr es no C hil ler

Pl an t P 2 1

6/V

A F res no C hil ler

Pl an t E lec

.rv t

2/5 /20

5:

:49

PM

EP101

CENTRAL PLANT ELECTRICAL ROOM FLOOR

PLAN

J. MONTANO R. RIBA02/02/2018

570-16-302PHASE 2 CHILLER

INFRASTRUCTURE ON FRESNO

CAMPUS

100% CONSTRUCTION DOCUMENTS

2615 E Clinton Ave, Fresno, CA 93703

SCALE: 1/4" = 1'-0"A1 CENTRAL PLANT ELECTRICAL ROOM FLOOR PLAN

GENERAL SHEET NOTES

KEYNOTES

1. EXISTING PANEL TO REMAIN. REFER TO SHEET E-701 FOR ADDITIONAL

INFORMATION.

2. REFER TO SHEET E-601 FOR ADDITIONAL INFORMATION.

3. REFER TO SHEET E-601 AND MECHANICAL DRAWINGS FOR ADDITIONAL

INFORMATION.

A. REFER TO SHEET E-001 FOR GENERAL NOTES.

0' 4' 8' 16'

NO

RT

H

FR

ES

NO

S

TR

EE

T

EAST HARVARD AVENUE

NO

RT

H

AN

GU

S

ST

RE

ET

EAST CLINTON AVENUE

TANK

O2

TANK

O2

KEY PLAN

B31

B3 B32

B24 B25

B2

B22A

B1

OPC

TEMP CANOPY

B27

B34

B3

B19& B19A

NOT IN CONTRACT.

BY OTHERS

1 1 1

M

(OFF)

RATED

HP

NEC FULL LOAD

CURRENT AT

480V, 3PH (AMPS)

MOTOR CALCULATED kVA

AT 480V, 3PH

NORMAL MOTORS LOADS

3 4.8 3.8

CHILLER CH-2

40 31.9COOLING TOWER 1 HEATER

PUMP CHWP2

PUMP CHP-2

CHILLER CH-3

FAN COIL FC-2

124 98.8

1 1.8 1.4FAN COIL FC-1

RATED

HP

NEC FULL LOAD

CURRENT AT

480V, 3PH (AMPS)

MOTOR CALCULATED kVA

AT 480V, 3PH

EMERGENCY MOTORS LOADS

TOTAL LOAD CONCEPT C-3

680.7

COOLING TOWER CT-1

30 40 31.9COOLING TOWER CT-2

CHILLER CH-1

PUMP CHWP-1

31.9

PUMP CHP-1

575 460

124 98.8

21 16.715

21 16.715

PUMP CWP-2

PUMP CWP-1 52 41.440

52 41.440

40 31.9COOLING TOWER 2 HEATER

575 460

PUMP CHWP3 124 98.8100

PUMP CHP-3 21 16.715

PUMP CWP-3 52 41.440

PUMP CWP-4 52 41.440

MOTORS LOAD SUMMARY

EXISTING MOTORS LOAD ON MCC1-2B

EMERGENCY MOTOR LOADS

NORMAL MOTOR LOADS

325.4 kVA

680.7 kVA

1,521.2 kVA

TOTAL MOTOR LOADS ON DSB-B22 2,527.3 kVA

L

E

N

MANHOLE MH-22 (E)

PRIMARY FEEDERS "SW-6" (E)

TEMPORARY FEED

PAD MOUNTED OIL

FILLED TRANSFORMER

'T-6' (E)

RELOCATED

TRANSFORMER "T-10"

1500kVA (E)

MANHOLE MH-2 (E)

DISTRIBUTION SWITCHBOARD SECTION

277/ 480V, 3PH, 4W, NEMA 3R, 4000 A, 100,000 AIC (E)

DRY-TYPE SUB-STATION TRANSFORMER SECTION

3000 KVA, NEMA 1, 12.47 KV: 277/480V (E)

MEDIUM VOLTAGE SWITCH SECTION

12.47 KV, 3PH, 3W, 95 KV BIL, NEMA 1, 25 KAIC (E)

(E) MANHOLE "MH-EDP"

(E) PRIMARY FEEDERS

200A

150E

MOTOR CONTROL CENTER MCC-6

1200A, 480V, 3PH, 3W, 65KAIC (E)

MOTOR CONTROL CENTER MCC-7

1200A, 480V, 3PH, 3W, 65KAIC (E)

XFMR "NX"

45KVA,

480-208V/120V

3PH-4W,

DRY-TYPE (E)

1 2 3 4 1 2 3 4 5

SPACE FOR

(2) 800A BREAKERS

MOTOR CONTROL CENTER MCC-E1

1200A, 480V, 3PH, 3W, 65KAIC (E)

1 2 3 4 5

XFMR "EX"

45KVA,

480-208V/120V

3PH-4W,

DRY-TYPE (E)

MANHOLE "MH-NP1" (E) (MH-6)

5 66 6 7

AUTOMATIC TRANSFER SWITCH "ATSE"

AND DISTRIBUTION SWITCHBOARD "SWBD E-B22" (E)

ATS 3-POLE, 2000A, 480V, SWBD TEST BY-PASS SWBD

480V, 3PH, 3W, 2000A, 100,000KAIC (E)

UNITS SUB-STATION "SN-B22" (E)

TO GND. BAR "G2"

TO GND. BAR "G2" TO GND. BAR "G2"

CUSTOMER OWNED METER (E)

8 8

SOLID

SEPARATOR

SSR-2

(15 HP)

TO GND. BAR "G2"

INFORMATION BELOW TAKEN FROM AS-BUILT

DRAWINGS, PROJECT NUMBER 570-13-300,

DATED 4-17-2015

UNLESS OTHERWISE SPECIFIED, ALL

DISTRIBUTION EQUIPMENT, BREAKERS,

DISCONNECTS, SWITCHES AND CONDUIT

ARE EXISTING TO REMAIN.

(E)

PUMP

CHP-3

(15 HP)

PUMP

CHWP3

(100 HP)

PUMP

CWP-3

(40 HP)

PUMP

CWP-4

(40 HP)

FAN

COIL

FC-1

FAN

COIL

FC-2

CHILLER

CH-3

(575 MCA)

SOLID

SEPARATOR

SSR-1

(15 HP)

PUMP

CHP-2

(15 HP)

PUMP

CHWP2

(100 HP)

PUMP

CWP-2

(40 HP)

COOLING

TOWER 1

HEATER

COOLING

TOWER 2

HEATER

SANIPAK

CHILLER

CH-2

(575 MCA)

(E)

CHILLER

CH-4

(213 FLA)

PUMP

CHWP1

(100 HP)

CHILLER

CH-1

(575 MCA)

PUMP

CHP-1

(15 HP)

PUMP

CWP-1

(40 HP)

COOLING

TOWER

CT-2

(30HP)

EXHAUST

FAN

EF-1

(1.5HP)

COOLING

TOWER

CT-1

(30HP)

PUMP 22-P3

(7.5 HP, 10.3 FLA)

RO UNIT

PANEL

"P" (E)

PANEL

"EP"

(E)

225A 225A

(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E)(E)(E)(E)(E)(E)(E)

(E)(E)

(E) (E)

(E)

(E)

(E)

(E)

(E)

(E)

(E) (E) (E) (E)

(E) (E)

(E)

(E)

(E) (E) (E) (E) (E) (E) (E)

(E)

(N) (E) (E) (E) (E) (E) (E)

(E)

(N)

G

(E)

(E)

(E) (E)

(E) (E) (E) (E)

(E)(E)

(N)

(N)

G G G G

M

G G

G

Δ

Y

Δ

Y

(E)

3P

MCP

MOTOR CONTROL CENTER MCC1-2B

1600A, 480V, 3PH, 3W, 65KAIC (E)

TOTAL LOAD CONCEPT C-3 1521.2

VFD VFDVFD

CHILLER CH-4 213 177

VFD VFD(N) (N)VFD (N)VFD (N)

MANHOLE "MH-NP2" (E) (MH-7)

(N)

TO BLDG

TO BLDG

(E) (E)

TO

BOILER

'EDP2'

TO CLC

(E) (E)

PB-2

TO

BLDG 22

(E)

(E)

TO CLC

EXPANSION

TO BLDG

PB-3

(E)

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in ch o ne fo o t o n e-h al f i n ch o n e fo o t th re e-qu ar te rs in ch o ne fo o t

6" o n e in ch o n e fo o t o n e an d o ne -h al f i n ch o ne fo o t th re e in ch es o ne fo o t

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

PROJECT TEAM ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

ISSUED FOR CONSTRUCTION

TRIPLE C - THE A-E GROUP

4401 ATLANTIC AVE. SUITE 200

LONG BEACH, CA 90807

CONTACT: DAVID POTTER

PHONE: 307 460-2054

SUBMISSION

BRIDGERS & PAXTON CONSULTING ENGINEERS, INC.

1839 S. ALMA SCHOOL ROAD, SUITE 300

MESA, AZ 85210

CONTACT: JOHN MONTANO

PHONE: 602 336-5415

UNITED STRUCTURAL DESIGN, LLC

720 W. COMMERCE AVE OR P.O. BOX 33245

GILBERT, AZ 85233 PHOENIX, AZ 85067

CONTACT: DAVID GRAPSAS

PHONE: 480 382-9768

2-2-18

BIM

0:/ /57

0-1 6-3

VA

Fr es no C hil ler

Pl an t P 2 1

6/V

A F res no C hil ler

Pl an t E lec

.rv t

2/5 /20

5:

:45

PM

E-601

ELECTRICAL ONE-LINE DIAGRAM-NEW

J. MONTANO R. RIBA02/02/2018

570-16-302PHASE 2 CHILLER

INFRASTRUCTURE ON FRESNO

CAMPUS

100% CONSTRUCTION DOCUMENTS

2615 E Clinton Ave, Fresno, CA 93703

GENERAL SHEET NOTES

KEYNOTES

1. REMOVE AND REPLACE EXISTING 450A CIRCUIT BREAKER AND STARTER.

PROVIDE (N) 450A/3P CIRCUIT BREAKER AS INDICATED. LOCATE IN MCC1-2B AS

INDICATED AND SPECIFIED BY VA.

2. CONTRACTOR TO PROVIDE LOAD MONITORING OF PANEL AND REPORT FINDINGS

TO ENGINEER PRIOR TO ANY WORK.

3. REMOVE AND REPLACE EXISTING DISCONNECT WITH NEW VFD. RECONNECT TO

EXISTING CIRCUIT. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL

INFORMATION.

4. EXISTING MANHOLE LOCATED SOUTH OF BUILDING 3 TO BE REPAIRED.

5. CORE DRILL EXISTING MANHOLE AND PROVIDE NEW 5" SLEEVES FOR ROUTING

NEW CABLES.

6. PROVIDE NEW 15KV CABLE IN CONCRETE ENCASED DUCTBANK. CABLE SHALL

BE INSTALLED PRIOR TO REMOVING EXISTING CABLE. SIZE TO MATCH EXISTING.

7. EXISTING 15KV CABLE SHALL BE REMOVED AFTER INSTALLATION OF NEW

CABLE.

8. SPLICE CABLE AND RECONNECT WITH EXISTING MANHOLE.

9. CORE DRILL EXISTING MANHOLE FOR NEW I5KV BYPASS FEEDER FROM MH-NP1.

10. MANHOLE TO BE REPAIRED.

A. REFER TO SHEET E-001 FOR GENERAL NOTES.

B. REFER TO SHEET E-701 FOR FEEDER SCHEDULE.

C. 15KV CABLE BYPASS INSTALLATION WILL REQUIRE ELECTRICAL SHUTDOWNS. THE

FOLLOWING BUILDINGS WILL BE AFFECTED:

BLDG 24, BLDG 25, BLDG 22, BLDG 22 BOILER, BLDG 27, CLC.

BUILDING 24 AND BUILDING 25 WILL REQUIRE TEMPORARY GENERATORS DURING

THE OUTAGE. THE OTHER BUILDINGS LISTED HAVE EXISTING GENERATOR BACKUP

TO BE USED.

SCALE: 12" = 1'-0"1 ELECTRICAL ONE LINE DIAGRAM-NEW

3 333

NOT IN CONTRACT.

BY OTHERS

<5'-0"

METER &

BACKFLOW

PREVENTER(S)

METER &

BACKFLOW

PREVENTER(S)

EXISTING

SERVICE

ENTRANCE

EQUIPMENT

GROUND NEUTRAL

GROUND NEUTRAL

MAIN GROUNDING

ELECTRODE

GROUND BAR (E)

BUILDING

STRUCTURAL

STEEL

GROUND NEUTRAL

BUILDING

STRUCTURAL

STEEL (E)

COLD

WATER PIPE

EXISTING

SWITCHBOARD,

DISTRIBUTION

BOARD

OR PANELBOARD

GRADE

GROUND NEUTRAL

EXISTING

OUTDOOR

TRANSFORMER

NOTE: ALL CONDUCTORS ARE COPPER.

SIZE OF LARGEST UNGROUNDED

SERVICE-ENTRANCE CONDUCTOR

OR EQUIVALENT AREA FOR

PARALLEL CONDUCTORS.

(AWG OR kCMIL)

SIZE OF GROUNDING

ELECTRODE

CONDUCTOR (AWG)

<= #2

#1 OR 1/0

2/0 OR 3/0

OVER 3/0

THROUGH 350

OVER 350

THROUGH 600

OVER 600

THROUGH 1100

OVER 1100

1/0

2/0

3/0

NEC TABLE 250.66

(E) (E)

(E)

TO AIR

TERMINALS (E)

AIR

TERMINALS (E)

(E)

(E)

(E)

(E)

(E)

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in ch o ne fo o t o n e-h al f i n ch o n e fo o t th re e-qu ar te rs in ch o ne fo o t

6" o n e in ch o n e fo o t o n e an d o ne -h al f i n ch o ne fo o t th re e in ch es o ne fo o t

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

PROJECT TEAM ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

ISSUED FOR CONSTRUCTION

TRIPLE C - THE A-E GROUP

4401 ATLANTIC AVE. SUITE 200

LONG BEACH, CA 90807

CONTACT: DAVID POTTER

PHONE: 307 460-2054

SUBMISSION

BRIDGERS & PAXTON CONSULTING ENGINEERS, INC.

1839 S. ALMA SCHOOL ROAD, SUITE 300

MESA, AZ 85210

CONTACT: JOHN MONTANO

PHONE: 602 336-5415

UNITED STRUCTURAL DESIGN, LLC

720 W. COMMERCE AVE OR P.O. BOX 33245

GILBERT, AZ 85233 PHOENIX, AZ 85067

CONTACT: DAVID GRAPSAS

PHONE: 480 382-9768

2-2-18

BIM

0:/ /57

0-1 6-3

VA

Fr es no C hil ler

Pl an t P 2 1

6/V

A F res no C hil ler

Pl an t E lec

.rv t

2/5 /20

5:

:45

PM

E-602

GROUNDING DIAGRAM

J. MONTANO R. RIBA02/02/2018

570-16-302PHASE 2 CHILLER

INFRASTRUCTURE ON FRESNO

CAMPUS

100% CONSTRUCTION DOCUMENTS

2615 E Clinton Ave, Fresno, CA 93703

GENERAL SHEET NOTES

KEYNOTES

A. INSTALL GROUNDING CONNECTIONS TO BUILDING STRUCTURE AND WATER PIPES AT

LOCATIONS THAT ARE VISIBLE AND ACCESSIBLE FOR INSPECTION, MAINTENANCE, AND

TESTING.

B. BOND ELECTRICAL EQUIPMENT ENCLOSURES TO GROUND BAR USING SAME SIZE

CONDUCTOR AS FEEDER EQUIPMENT GROUND CONDUCTOR OR FACTORY PROVIDED

GREEN SCREW.

C. CLEAN COATED RE-BAR PRIOR TO PERFORMING ELECTRICAL CONNECTION.

1 EXISTING 1/4" X 4" X 12" "MAIN GROUNDING ELECTRODE GROUND BAR" FOR

SINGLE POINT GROUNDING.

2 EXISTING BONDING JUMPER SIZED PER GROUNDING ELECTRODE

CONDUCTOR SCHEDULE THIS SHEET

3 EXISTING LIGHTNING PROTECTION GROUND ROD.

25Δ

40Δ 35Δ 30Δ

45Δ 50Δ 60Δ 70Δ

90Δ 80Δ

125Δ 100Δ

200Δ 175Δ

225Δ 250Δ

150Δ

300Δ 350Δ

450Δ 400Δ

700Δ 600Δ

800Δ 1000Δ

500Δ

1200Δ 1600Δ

2500Δ 2000Δ

3000Δ

NOTE:

NOTESDESIGNATION

35Y 40Y

30Y

45Y 50Y 60Y 70Y 80Y 90Y

125Y 100Y

175Y 200Y 225Y 250Y

150Y

300Y 350Y

450Y 400Y

600Y 700Y 800Y

1000Y

500Y

1200Y 1600Y 2000Y 2500Y 3000Y

25Y 20Y

20Δ

4000Δ

4000Y 5000Y

CONDUCTORS

4#6

(3) 4-600 KCMIL

(4) 4-600 KCMIL

(5) 4-600 KCMIL

(8) 4-500 KCMIL

(6) 4-600 KCMIL

(10) 4-600 KCMIL

(12) 4-600 KCMIL

(2) 4-250 KCMIL

(2) 4-350 KCMIL

(2) 4-500 KCMIL

(2) 4-600 KCMIL

(3) 4-400 KCMIL

4-250 KCMIL

(2) 4#4/0

4-350 KCMIL

4-500 KCMIL

4-600 KCMIL

4#4 4#4 4#2 4#2

4#1/0 4#2/0 4#3/0 4#4/0

4#1

4#10 4#10 4#12

4#8 4#8 4#8 4#8

GROUND

(3) 3/0

(4) 4/0

(5) 250 KCMIL

(6) 350 KCMIL

(8) 400 KCMIL

(10) 500 KCMIL

(12) 700 KCMIL

(2) 2

(2) 1

(2) 1

(2) 2

(2) 1/0

(3) 2/0

CONDUIT

(3) 4"

(4) 4"

(5) 4"

(6) 4"

(8) 4"

(10) 4"

(12) 4"

3"

(2) 3"

(2) 4"

(2) 4"

(3) 3"

(2) 3"

(2) 2 1/2"

4"

3" 4"

1 1/4" 1 1/4" 1 1/4" 1 1/4"

2 1/2"

1 1/2"

2"

2" 2"

3/4" 3/4" 1"

3/4" 3/4"

3/4"

3/4" 3/4"

(6) 3-600 KCMIL

(8) 3-500 KCMIL

(10) 3-600 KCMIL

(5) 3-600 KCMIL

(2) 3-600 KCMIL

(4) 3-600 KCMIL

(3) 3-600 KCMIL

(3) 3-400 KCMIL

(2) 3-250 KCMIL

(2) 3-500 KCMIL

(2) 3-350 KCMIL

3-600 KCMIL

(2) 3#4/0

3#1 3#2

3#2/0 3#1/0

3#4/0 3#3/0

3-250 KCMIL

3-500 KCMIL

3-350 KCMIL

3#10

3#8 3#10

3#8 3#8

3#6 3#4

3#8

3#2 3#4

3#12

(8)400 KCMIL

(6)350 KCMIL

(10)500 KCMIL

(2) 2

(2) 1

(2) 1

(2) 2

(5)250 KCMIL

(4) 4/0

(3) 3/0

(3) 2/0

(2) 1/0

(6) 4"

(8) 4"

(10) 4"

4"

(2) 4"

(2) 3"

(2) 3"

(3) 3"

(5) 4"

(4) 4"

(3) 4"

(2) 4"

(2) 2 1/2"

1 1/2" 1 1/4"

1 1/2"

2 1/2" 2"

3" 4"

3"

2"

3/4"

1 1/4" 1 1/4" 1 1/4"

1" 3/4"

3/4"

3/4" 3/4"

3/4"

3/4"

ALL CONDUCTORS ARE COPPER, TYPE THWN/THHN UNLESS OTHERWISE NOTED.

100Y-E 150Y-E

225Y-E

350Y-E

500Y-E

400Y-E

3#2, 1#4/0 NEUTRAL

3#2/0, 2#2/0 NEUT.

(2) 2

(2) 2

(2) 2

6 2"

2 1/2"

2"

(2) 3"

(2) 2 1/2"

(2) 2 1/2"

20YS THRU 100YS

125YS THRU 150YS

4175YS THRU 200YS

2225YS THRU 300YS

1/0350YS THRU 500YS

2/0600YS THRU 700YS

GROUNDDESIGNATION

800YS THRU 5000YS 3/0

THREE PHASE THREE WIRE & GROUND FEEDER

COPPER FEEDER SCHEDULE

EQUIPMENT BONDING JUMPER FOR SEPARATELY DERIVED SYSTEMS PER NEC 250.66

(PROVIDE CONDUCTOR GROUND BELOW INSTEAD OF FEEDER GROUND FOR THREE PHASE,

4-WIRE SYSTEMS INDICATED ABOVE)

THREE PHASE FOUR WIRE & GROUND FEEDER

THREE PHASE FOUR WIRE 200% NEUTRAL & GROUND FEEDER

3-250 KCMIL,

2-250 KCMIL NEUT.

(2) 3#3/0,

(2) 2#3/0 NEUT.

(2) 3#4/0,

(2) 2#4/0 NEUT.

(2) 3-350 KCMIL,

(2) 2-350KCMIL NEUT.

TRENCH

GRADE

WARNING TAPE

#4/0 COPPER GROUND

CONDUCTOR

P

12" MINIMUM

6"

COMPACTED

BACKFILL

5" CONDUIT. REFER

TO DRAWINGS FOR

ADDITIONAL

INFORMATION

3"

(TYP)

5"

36" MINIMUM

D

GE R

L

A

CI

RT

CE

L

REENIGNELANOISSEFORP

DERET

S I

CIFITREC .ON

ETA

ATE

S I GNED

A R I Z ON A U . S . A .

E

38934

JOHN M.

MONTANO

EXPIRES 3/31/2018

o n e-ei g h th in ch o n e fo o t o n e-q u ar te r in ch o n e fo o t th re e-ei g ht h in…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.