36C25518Q0169-00003006.pdf

PDF 6 MB Posted

Attached to
657-18-1-1582-0008 Asbestos Lead Survey - STL
Solicitation number
36C25518Q0169
Issued by

About this file

36C25518Q0169 00003 08-14529 JC Bldg 07 Report.pdf

View the file

Other files

File Type Posted
36C25518C0113-000.docx DOCX document
36C25518Q0169-00003004.pdf PDF
36C25518Q0169-00003005.pdf PDF
36C25518Q0169-00003007.pdf PDF
36C25518Q0169-00003010.pdf PDF
36C25518Q0169-00003008.pdf PDF
36C25518Q0169-00003000.docx DOCX document
36C25518Q0169-00003002.pdf PDF
36C25518Q0169-00003003.pdf PDF
36C25518Q0169-00003001.pdf PDF
36C25518Q0169-00003009.pdf PDF
36C25518Q0169-00002033.pdf PDF
36C25518Q0169-00002050.pdf PDF
36C25518Q0169-00002031.pdf PDF
36C25518Q0169-00002055.pdf PDF
36C25518Q0169-00002047.pdf PDF
36C25518Q0169-00002053.pdf PDF
36C25518Q0169-00002038.pdf PDF
36C25518Q0169-00002045.pdf PDF
36C25518Q0169-00002039.pdf PDF
36C25518Q0169-00002052.pdf PDF
36C25518Q0169-00002037.pdf PDF
36C25518Q0169-00002032.pdf PDF
36C25518Q0169-00002036.pdf PDF
36C25518Q0169-00002040.pdf PDF
36C25518Q0169-00002043.pdf PDF
36C25518Q0169-00002042.pdf PDF
36C25518Q0169-00002048.pdf PDF
36C25518Q0169-00002028.docx DOCX document
36C25518Q0169-00002054.pdf PDF
36C25518Q0169-00002035.pdf PDF
36C25518Q0169-00002041.pdf PDF
36C25518Q0169-00002058.pdf PDF
36C25518Q0169-00002030.pdf PDF
36C25518Q0169-00002049.pdf PDF
36C25518Q0169-00002046.pdf PDF
36C25518Q0169-00002044.pdf PDF
36C25518Q0169-00002057.pdf PDF
36C25518Q0169-00002029.pdf PDF
36C25518Q0169-00002051.pdf PDF
36C25518Q0169-00002034.pdf PDF
36C25518Q0169-00002056.pdf PDF
36C25518Q0169-00001000.docx DOCX document
36C25518Q0169-004.pdf PDF
36C25518Q0169-002.pdf PDF
36C25518Q0169-001.docx DOCX document
36C25518Q0169-003.pdf PDF
36C25518Q0169-000.docx DOCX document
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS ASSESSMENT

ASBESTOS REINSPECTION REPORT

John Cochran Division 915 North Grand Boulevard

St. Louis, Missouri

Building 7

Prepared for:

St. Louis V. A. Medical Center 915 North Grand Boulevard

St. Louis, Missouri

Prepared by:

1421 Clarkview Road, Suite 100 P. O. Box 17867 Baltimore, MD 21209 Shreveport, Louisiana 71138-0867

(888) 776-0670 (318) 687-3771

INTRODUCTION

2008 ASBESTOS REINSPECTION REPORT

ST. LOUIS V. A. MEDICAL CENTER

JOHN COCHRAN AND JEFFERSON BARRACKS DIVISIONS

SCOPE OF WORK

1. The Inspector and Management Planner reviewed prior inspections and Management Plan information on file and compared this information with existing conditions for each facility.

2. This asbestos reinspection complies with the requirements of Asbestos Hazard Emergency Response Act (AHERA).

3. Each facility inspection was performed by an accredited inspector.

4. For each facility, the inspector performed the following tasks:

a. Visually reinspected and reassessed the condition of all friable known or assumed

ACBM.

b. Visually inspected material that was previously considered non-friable Asbestos- Containing Building Material (ACBM) and touched the material to determine whether it has become friable since the last inspection.

c. Identified any homogeneous areas with material that has become friable since the last inspection or reinspection.

d. The inspector collected bulk samples for analysis of newly friable material that is already assumed (not sampled) to be ACBM or collected additional bulk samples to fully assess the suspect materials.

e. Visually inspected, sampled, analyzed, and assessed the conditions of building materials that have been added to the facility since the last inspection or reinspection.

f. Assessed the condition of the newly friable material in areas where samples were collected and of newly friable material in areas assumed to be ACBM.

g. Reassessed the condition of friable known or assumed ACBM previously identified.

h. Recorded above information on field inspection forms for each facility.

5. A Management Planner reviewed the above information and performed the following required functions:

a. Reviewed each Management Plan for compliance with AHERA and verified that the plan reflects current conditions.

b. Reviewed the results of each reinspection and assessment.

c. Recommended in writing, the appropriate response actions.

d. Signed and dated the review documents, included the accreditation number of inspectors and planners, and submitted a copy to the Designated Person.

6. The following information was submitted to the Designated Person under AHERA, for inclusion in the Management Plan for each facility and, optionally, at a central office location.

a. The date of the inspection, the name and signature of the person making the inspection, state of accreditation, his or her accreditation number, and any changes in the condition of known or assumed ACBM.

b. If samples were collected, the exact locations where samples are collected during the inspection, a description of the manner used to choose sampling locations, the name and signature of each accredited inspector who collected the samples, state of accreditation, and his or her accreditation number.

c. Any assessments or reassessments made of friable material, the name and signature of the accredited inspector making the assessments, state of accreditation, and his or her accreditation number.

MANAGEMENT PLAN RECOMMENDATIONS

The following general notes are for all facilities inspected during the Asbestos Reinspection.

These notes reference any deficiencies found in prior inspections, reinspections, and the current Management Plan.

1. Removal Priorities were developed for each homogeneous area. The Removal Priorities are an indicator of priorities for future repair work or abatement work to be scheduled as financial budgets allow. Please see the 2008 Reinspection Condition and Removal Priority Table for further detail.

2. The current condition of material was listed for each homogeneous area. The condition, location, and potential for disturbance factors are used for the hazard ranking. Please see the 2008 Reinspection Condition and Removal Priority Table for the condition summaries.

3. Records for custodial, janitorial, and maintenance staff who have received two-hour awareness training should be filed in the Management Plan.

4. Any new custodial, janitorial, or maintenance staff that have the potential to come in contact with asbestos-containing materials (ACM) are required to attend a two-hour awareness training class. Records of training for new employees should be filed in the Management Plan.

5. The Designated Person is required to inform workers and building occupants at least once a year about the Management Plan. This includes information about inspections, response actions, and post-response action activities that are planned or in progress.

Provide a copy of the notification to each facility and include a copy in the Management Plan.

6. Maintenance areas (boiler rooms, janitor closets, etc.) are required to have warning labels where ACM are located. Install warning labels in these areas as needed. Some older labels may have come loose and are no longer visible. Post the labels in a prominent location.

7. Review the enclosed 2008 Reinspection Condition and Removal Priority Table for maintenance actions that may be required and to establish priorities and budgets for future repair and abatement work.

8. Periodic “Surveillance Inspections” are required every six (6) months. This inspection should indicate the condition of the material and provide recommendations for repair or potential removal. Consistency of inspections is desired and, therefore, should be performed by the same individual(s) for all facilities. An accredited inspector is not required, but is recommended. Records of Surveillance Inspections should be filed in both the administrative and facility Management Plans.

9. ”Reinspections” are required every three (3) years. Updated information should be added to the Management Plan.

10. The existing Management Plan (original) is updated by this Three-Year Reinspection.

All procedures and methods listed in the Plan are still in effect and should be followed unless specifically updated or omitted by this inspection. This includes maintenance procedures, repairs to damaged material, response actions, record keeping, surveillance inspections, and training.

11. An accredited “Supervisor” should be on staff or available on a contract basis per AHERA guidelines. Certification paperwork should be filed in the training section of the Management Plan.

12. ACBM should only be removed by licensed and accredited contractors in the State of Missouri. Response actions related to abatement activity should be filed in the Management Plan. Removal of limited amounts of asbestos is within the scope of the Management Plan by the accredited Supervisor and trained individuals.

13. Notification should be provided to “outside contractors” about ACM within the facility.

This should include such trades or services as telephone, electrical, plumbing, air conditioning, and other construction work. A form should be created for this purpose and placed in the Management Plan.

14. New building construction and portable buildings added to a facility are required to be inspected and sampled for ACM. In lieu of this, a letter from the architect, engineer, or manufacturer can be obtained that states “no ACM were specified or used in the facility”.

A copy of this letter is to be filed with the Management Plan at the facility. This letter will cancel the requirement for sampling.

15. Abatement Costs were developed for each homogeneous area and per facility. The estimated abatement cost is for budget purposes only. The cost is based on the area of material and estimated abatement costs for this material. The cost is for abatement only and does not include abatement design, air monitoring, or project observation costs.

REPORT SECTION

This report includes the following sections:

ACM Homogeneous Areas Summary Table and Drawings

This section provides a quick table reference to all asbestos-containing homogeneous areas found during the reinspection and drawings with the asbestos-containing homogeneous areas found during the 2008 asbestos reinspection.

Condition and Removal Priority Table

This section provides a table with the current condition, potential for disturbance, and removal priority for each homogeneous area.

Master Summary Table – Asbestos Bulk Samples

This table provides a listing of all asbestos bulk samples taken to date.

Asbestos-Containing Bulk Samples

This table provides a listing of all asbestos-containing bulk samples.

2008 Reinspection – Inspection Logs

This section provides the field inspection logs for samples taken during the 2008 asbestos reinspection.

Bulk Sample Location Drawings

This section provides drawings with sample locations for all asbestos bulk samples.

2008 Reinspection – Photographs

This section provides photographs of all asbestos bulk samples taken during the 2008 asbestos reinspection.

2008 Reinspection – Laboratory Reports

This section provides all laboratory analytical results.

Certifications

This section provides certifications for all Inspectors, the Management Planner who reviewed this Management Plan, and the laboratory that performed the bulk sample analysis.

Periodic Surveillance Forms

This section includes the forms completed during the periodic surveillance inspections required every six (6) months.

Management Plan Updates

This section includes the records of any asbestos abatement activities that are completed at the subject site. Notifications, daily notes, drawings, etc., should be placed in this section. This would also include air-monitoring data from asbestos abatement projects.

Response Actions

This section includes the records of any internal asbestos abatement or operation and maintenance activities that may be completed by V. A. employees. This would include any drawings, field notes, and air monitoring that was completed.

Training Documents

This section includes the records of training for the Designated Person and accredited Supervisor, as well as the two-hour awareness training for the custodial, janitorial, and maintenance staff.

Annual Notification Letters

This section includes copies of the annual Notification Letters provided to employees to inform them of the availability of the Management Plan.

Initial Inspection

This section contains the original asbestos inspection that was completed in 1994. This information was used to develop the 2008 Asbestos Reinspection.

CONTRACTORS

This 2008 Asbestos Reinspection was provided by:

Contractor: Subcontractor:

FINBACK 670, Inc. ALTEC Environmental Consultants, Inc.

1421 Clarkview Road, Suite 100 10100 Woolworth Road Baltimore, MD 21209 Keithville, LA 71047

(888) 776-0670 (Office) (318) 687-3771 (Office)

(877) 776-0670 (Fax) (318) 687-9923 (Fax)

INSPECTORS:

Brandon Odom Donald R. Joiner LA Certificate No. 9I01392 LA Certificate No. 8I01348 LA Certificate No. 9I01348

Eric Clipps Joshua Anders LA Certificate No. 9I01588 LA Certificate No. 9I01589

Justin L. Holcomb LA Certificate No. 9I00306

MANAGEMENT PLANNER:

Roy W. Dowling LA Certificate No. 9I00213 – Inspector LA Certificate No. 9P00072 – Management Planner

Accreditation Agency: Louisiana Department of Environmental Quality

ACM Homogeneous Areas Summary Table and Drawings

JOHN COCHRAN DIVISION

2008 THREE-YEAR ASBESTOS REINSPECTION

ACM HOMOGENEOUS AREAS SUMMARY TABLE

Floor Flooring Materials Surfacing Materials TSI Materials Miscellaneous Materials

Basement No ACM No ACM HMA-02 Pipe Insulation & Fittings HMA-06 Tank Insulation No ACM

Floor Flooring Materials Surfacing Materials TSI Materials Miscellaneous Materials

1 HMA-01 12x12 Floor Tile & Adhesive No ACM No ACM HMA-03 Black Pegboard

HAM-04 Transite Vent Hoods HMA-05 Lab Countertops

Building 7 - Basement

Building - 1st Floor

BASEMENT

ST. LOUIS V.A. MEDICAL CENTER

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 1 magnesia pipe lagging 226 lf 0 4.00 1 magnesia pipe lagging 3 lf 0 8.00 1 magnesia pipe lagging 3 lf 0 10.00 1 magnesia pipe lagging 20 lf 0 12.00 1 magnesia pipe lagging 3 lf 0 14.00 1 mudded joint fitting on mag pipe la 0 ea 12 12.00 1 mudded joint fitting on paperwrap l 0 ea 3 6.00 1 paper wrap pipe lagging 3 lf 0 6.00 1 tank insulation 0 sf 0 2.00 1 tank insulation 22 sf 0 2.00

001A magnesia pipe lagging 42 lf 0 4.00 001A magnesia pipe lagging 26 lf 0 12.00 001A mudded joint fitting on mag pipe la 0 ea 8 4.00 001A mudded joint fitting on mag pipe la 0 ea 4 12.00

2 magnesia pipe lagging 782 lf 0 4.00 2 magnesia pipe lagging 85 lf 0 6.00 2 mudded joint fitting on mag pipe la 0 ea 165 4.00 2 mudded joint fitting on mag pipe la 0 ea 13 6.00

1215 205

Building 7 - Basement

TOTALS

1st FLOOR

Condition and Removal Priority Table

Qualitative Ranking Numerical Rating

Good 8, 9, 10

Fair 4, 5, 6, 7

Poor 1, 2, 3

Physical Disturbance Environmental Disturbance

Low 1, 2, 3

Medium 4, 5, 6, 7

High 8, 9, 10

Qualitative Ranking Numerical Rating High 1, 2, 3

Medium 4, 5, 6, 7

Low 8, 9, 10

1 Qualitative Rankings and Quantitative (Numerical) Ratings for Current Condition

2 Qualitative Rankings and Quantitative (Numerical) Ratings for Potential for Disturbance

Assessment FactorsQualitative Ranking Numerical Rating

Description of Current Condition Surfacing material has no visible damage or small amounts of damage; covering on thermal system insulation is intact or has small amounts of damage; miscellaneous materials intact; no visible debris or small amounts of debris.

Address with on-going maintenance procedures

Maintain in good condition

Surfacing material has moderate but not extensive amounts of visible damage; covering on thermal system insulation is cut or torn, exposing moderate but not extensive amounts of insulation; moderate but not extensive damage to miscellaneous materials such as floor tile; moderate but not extensive amounts of visible dust and debris..

3 Qualitative Rankings and Quantitative (Numerical) Ratings for Removal Priority

Description of Current Condition Address short-term

Extensive damage to surfacing material; covering on thermal system insulation is cut or torn extensively and insulation itself is damage; miscellaneous materials such as floor tile extensively damaged and underlying mastic exposed; extensive amounts of dust and debris.

Accessibility: accessibility during normal operations

Activities: activities that people do and how often they do them

Vibration: vibration from operating machinery, HVAC equipment, and so forth

Air/Dust: air currents strong enough to dislodge loose ACM; airborne dust that can erode material

Corrosive: corrosive atmosphere or liquids that can erode the covering or matrix

Water Damage: water damage from leaking roof, pipe or other source

2008 THREE-YEAR ASBESTOS REINSPECTION

CONDITION AND REMOVAL PRIORITY TABLE

Rating Based On Rating Based On

HMA-02 7 Basement Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-06 7 Basement Tank Insulation Yes No 7 Damage 2 Maintenance 6

HMA-01 7 1 12x12 Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-03 7 1 Black Pegboard No No 9 Minor Penetrations 2 Access 9

HAM-04 7 1 Transite Vent Hoods No No 10 Intact 1 Access 9

HMA-05 7 1 Lab Countertops No Yes 10 Intact 1 Maintenance 10

Building 7 - 1st Floor

Current Condition 1

Building 7 - Basement

Friable Yes/No

Accessibility Yes/No

Restricted

Potential for Disturbance 2

Homogeneous Area No. Bldg Floor Material Description

Removal Priority 3

Master Summary Table Asbestos Bulk Samples

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

JC07 00 001 JC-07-00-T-001-02 Tank insulation JC07 00 002 JC-07-00-T-002-08 Magnesia pipe lagging JC07 00 002 JC-07-00-T-002-07 Mudded joint fitting on magnesia pipe lagging

JC07 1 107 JC-7-01-F-107-001A White 12x12 floor tile, black mastic JC07 1 107 JC-7-01-M-107-002A Transite vent hood JC07 1 107 JC-7-01-M-107-003A Black lab countertop JC07 1 106 JC-7-01-F-106-004A White 12x12 floor tile, black mastic JC07 1 106 JC-7-01-M-106-005A Brown baseboard, adhesive JC07 1 103 JC-7-01-F-103-006A White 12x12 floor tile, black mastic JC07 1 103 JC-7-01-M-103-007A Brown baseboard, adhesive JC07 1 102 JC-7-01-M-102-008A Brown baseboard, adhesive JC07 1 21 JC-7-01-F-21-009A Green 12x12 floor tile, black mastic JC07 1 10 JC-7-01-F-10-010A Gray 12x12 floor tile, black mastic JC07 1 21 JC-7-01-M-21-011A 2x2 ceiling tile JC07 1 7A JC-7-01-M-7A-012A Gray baseboard, adhesive JC07 1 7A JC-7-01-F-7A-013A Gray 12x12 floor tile, black mastic JC07 1 10 JC-7-01-M-10-014A Black lab countertop JC07 1 10 JC-7-01-M-10-015A Black peg board JC07 1 21 JC-7-01-T-21-016A 3" elbow - white wrap, white block insulation JC07 1 21 JC-7-01-T-21-017A 3" horizontal - white wrap, yellow insulation JC07 1 6 JC-7-01-M-6-018A Black lab countertop JC07 1 6 JC-7-01-M-6-019A Transite vent hood JC07 1 6 JC-7-01-F-6-020A Gray 12x12 floor tile, black mastic JC07 1 102 JC-7-01-M-102-021A 2x4 ceiling tile JC07 1 108 JC-7-01-M-108-022A 2x4 ceiling tile JC07 1 108 JC-7-01-M-108-023A 2x4 ceiling tile JC07 1 16 JC-7-01-M-16-024A Gray baseboard, adhesive JC07 1 22 JC-7-01-F-22-025A Green 12x12 floor tile, black mastic JC07 1 22 JC-7-01-M-22-026A 2x2 ceiling tile JC07 1 23 JC-7-01-M-23-027A 2x2 ceiling tile JC07 1 22 JC-7-01-F-22-028A Green 12x12 floor tile, black mastic JC07 1 23 JC-7-01-M-23-029A Gray baseboard, adhesive JC07 1 1A JC-7-01-M-1A-030A Sheetrock mud JC07 1 1 JC-7-01-M-1-031A Black peg board JC07 1 2 JC-7-01-M-2-032A Black peg board JC07 1 2 JC-7-01-M-2-033A Sheetrock mud JC07 1 19 JC-7-01-M-19-034A Sheetrock mud JC07 1 Attic JC-7-01-T-AT-035A 4" T - white wrap, white block insulation JC07 1 Attic JC-7-01-T-AT-036A 4" horizontal - white wrap, yellow insulation

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

1994 Initial Asbestos Inspection

2008 Asbestos Reinspection

Asbestos-Containing Bulk Samples

2008 THREE-YEAR ASBESTOS REINSPECTION

LIST OF ASBESTOS-CONTAINING SAMPLES

Building Floor Room Sample ID Material Description

JC07 00 001 JC-07-00-T-001-02 Tank insulation JC07 00 002 JC-07-00-T-002-08 Magnesia pipe lagging JC07 00 002 JC-07-00-T-002-07 Mudded joint fitting on magnesia pipe lagging

JC07 1 21 JC-7-01-F-21-009A Green 12x12 floor tile, black mastic JC07 1 10 JC-7-01-F-10-010A Gray 12x12 floor tile, black mastic JC07 1 7A JC-7-01-F-7A-013A Gray 12x12 floor tile, black mastic JC07 1 10 JC-7-01-M-10-014A Black lab countertop JC07 1 10 JC-7-01-M-10-015A Black peg board JC07 1 6 JC-7-01-M-6-019A Transite vent hood JC07 1 6 JC-7-01-F-6-020A Gray 12x12 floor tile, black mastic JC07 1 22 JC-7-01-F-22-025A Green 12x12 floor tile, black mastic JC07 1 22 JC-7-01-F-22-028A Green 12x12 floor tile, black mastic JC07 1 1 JC-7-01-M-1-031A Black peg board JC07 1 2 JC-7-01-M-2-032A Black peg board

1994 Initial Asbestos Inspection

2008 Asbestos Reinspection

2008 Reinspection Inspection Logs

Client: Date: September 17, 2008 Location: Inspector(s): Brandon Odom and Eric Clipps Address: 915 North Grand Boulevard, St. Louis, Missouri

Note:

Sample ID Material Description Floor Room Location

JC-7-01-F-107-001A White 12x12 floor tile, black mastic 1 107 Northeast corner of room 107

JC-7-01-M-107-002A Transite vent hood 1 107 Southwest corner of room 107

JC-7-01-M-107-003A Black lab countertop 1 107 Northwest corner of room107

JC-7-01-F-106-004A White 12x12 floor tile, black mastic 1 106 Northwest corner of room 106

JC-7-01-M-106-005A Brown baseboard, adhesive 1 106 Southwest corner of room 106

JC-7-01-F-103-006A White 12x12 floor tile, black mastic 1 103 Southwest quadrant of room 103

JC-7-01-M-103-007A Brown baseboard, adhesive 1 103 Northwest quadrant of room 103

JC-7-01-M-102-008A Brown baseboard, adhesive 1 102 North side of room 102

JC-7-01-F-21-009A Green 12x12 floor tile, black mastic 1 21 Southeast quadrant of room 21

JC-7-01-F-10-010A Gray 12x12 floor tile, black mastic 1 10 North side of room 10

JC-7-01-M-21-011A 2x2 ceiling tile 1 21 Center of room 21

JC-7-01-M-7A-012A Gray baseboard, adhesive 1 7A North side of room 7A

JC-7-01-F-7A-013A Gray 12x12 floor tile, black mastic 1 7A Northwest quadrant of room 7A

JC-7-01-M-10-014A Black lab countertop 1 10 Southeast quadrant of room 10

JC-7-01-M-10-015A Black pegboard 1 10 East side of room 10

ASBESTOS INSPECTION LOG

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Green = Non ACM (determined by Point Count analysis)

John Cochran Division - Building 7 St. Louis V. A. Medical Center

Address: 915 North Grand Boulevard, St. Louis, Missouri

Note:

Sample ID Material Description Floor Room Location

ASBESTOS INSPECTION LOG

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Green = Non ACM (determined by Point Count analysis)

John Cochran Division - Building 7 St. Louis V. A. Medical Center

JC-7-01-T-21-016A 3" elbow - white wrap, white block insulation 1 21 Center of room 21

JC-7-01-T-21-017A 3" horizontal - white wrap, yellow insulation 1 21 Center of room 21

JC-7-01-M-6-018A Black lab countertop 1 6 Northwest corner of room 6

JC-7-01-M-6-019A Transite vent hood 1 6 Northwest corner of room 6

JC-7-01-F-6-020A Gray 12x12 floor tile, black mastic 1 6 Northwest corner of room 6

JC-7-01-M-102-021A 2x4 ceiling tile 1 102 West side of room 102

JC-7-01-M-108-022A 2x4 ceiling tile 1 108 North side of room 108

JC-7-01-M-108-023A 2x4 ceiling tile 1 108 South side of room 108

JC-7-01-M-16-024A Gray baseboard, adhesive 1 16 Northeast corner of room 16

JC-7-01-F-22-025A Green 12x12 floor tile, black mastic 1 22 At threshold to room 16 in room 22

JC-7-01-M-22-026A 2x2 ceiling tile 1 22 Center of room 22

JC-7-01-M-23-027A 2x2 ceiling tile 1 23 Center of room 23

JC-7-01-F-22-028A Green 12x12 floor tile, black mastic 1 22 South side of room 22

JC-7-01-M-23-029A Gray baseboard, adhesive 1 23 South side of room 23

JC-7-01-M-1A-030A Sheetrock mud 1 1A North side of room 1A

Address: 915 North Grand Boulevard, St. Louis, Missouri

Note:

Sample ID Material Description Floor Room Location

ASBESTOS INSPECTION LOG

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Green = Non ACM (determined by Point Count analysis)

John Cochran Division - Building 7 St. Louis V. A. Medical Center

JC-7-01-M-1-031A Black pegboard 1 1 Center of room 1

JC-7-01-M-2-032A Black pegboard 1 2 West side of room 2

JC-7-01-M-2-033A Sheetrock mud 1 2 North side of room 2

JC-7-01-M-19-034A Sheetrock mud 1 19 Southeast corner of room 19

JC-7-01-T-AT-035A 4" T - white wrap, white block insulation 1 Attic In attic above room 4

JC-7-01-T-AT-036A 4" horizontal - white wrap, yellow insulation 1 Attic In attic above room 4

GOOD = Surfacing material has no visible damage or small amounts of damage; covering on thermal system insulation is intact or has small amounts of damage; miscellaneous materials intact; no visible debris or small amounts of debris. FAIR = Surfacing material has moderate but not extensive amounts of visible damage; covering on thermal system insulation is cut or torn, exposing moderate but not extensive amounts of insulation; moderate but not extensive damage to miscellaneous materials such as floor tile; moderate but not extensive amounts of visible dust and debris. POOR = Extensive damage to surfacing material; covering on thermal system insulation is cut or torn extensively and insulation itself is damaged; miscellaneous materials such as floor tile extensively damaged and underlying mastic exposed; extensive amounts of dust and debris.

Material Category: F = Flooring S = Surfacing T = TSI M = Miscellaneous Friability: F=Friable NF=Non-Friable Condition: Good = 8, 9, 10 Fair = 4, 5, 6, 7 Poor = 1, 2, 3

Red = Asbestos-Containing Material Blue = Non Asbestos-Containing MaterialPlease use the following guidelines when reading this report:

Bulk Sample Location Drawings

BASEMENT

1st FLOOR

2008 Reinspection Photographs

BUILDING 7

sample does not contain asbestos

JC-7-01-F-107-001A JC-7-01-M-107-002A

JC-7-01-M-107-003A JC-7-01-F-106-004A

sample contains asbestos

JC-7-01-M-106-005A JC-7-01-F-103-006A

JC-7-01-M-103-007A JC-7-01-M-102-008A

JC-7-01-F-21-009A JC-7-01-F-10-010A

JC-7-01-M-21-011A JC-7-01-M-7A-012A

JC-7-01-F-7A-013A JC-7-01-M-10-014A

JC-7-01-M-10-015A JC-7-01-T-21-016A and JC-7-01-T-21-017A

JC-7-01-M-6-018A, JC-7-01-M-6-019A, and JC-7-01-F-6-020A JC-7-01-M-102-021A

JC-7-01-M-108-022A JC-7-01-M-108-023A

JC-7-01-M-16-024A JC-7-01-F-22-025A

JC-7-01-M-22-026A JC-7-01-M-23-027A

JC-7-01-F-22-028A JC-7-01-M-23-029A

JC-7-01-M-1A-030A JC-7-01-M-1-031A

JC-7-01-M-2-032A JC-7-01-M-2-033A

JC-7-01-M-19-034A JC-7-01-T-AT-035A and JC-7-01-T-AT-036A

2008 Reinspection Laboratory Reports

Sample Location Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804605

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/18/08 4:50 PM

08-14529 VAMC Reinspection JC Building 7

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/18/2008Analysis Date:

Report Date: 9/19/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-7-01-F-107-

001A floortile 390804605-0001

WHT 12X12 FT

W/BLK MASTIC

White None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-7-01-F-107-

001A adhesive 390804605-0001A

WHT 12X12 FT

W/BLK MASTIC

Black None Detected

Non-Fibrous

Heterogeneous

Cellulose9% Non-fibrous (other)91%

JC-7-01-M-107-

002A 390804605-0002

TRANSITE VENT

HOOD

Gray None Detected

Non-Fibrous

Heterogeneous

Cellulose10% Wollastonite9%

Non-fibrous (other)81%

JC-7-01-M-107-

003A 390804605-0003

BLK LAB

COUNTERTOP

Black None Detected

Non-Fibrous

Heterogeneous

Cellulose10% Wollastonite9%

Non-fibrous (other)81%

JC-7-01-F-106-

004A floortile 390804605-0004

WHT 12X12 FT

W/BLK MASTIC

White None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-7-01-F-106-

004A adhesive 390804605-0004A

WHT 12X12 FT

W/BLK MASTIC

Black None Detected

Non-Fibrous

Heterogeneous

Cellulose9% Non-fibrous (other)91%

JC-7-01-M-106-

005A covebase 390804605-0005

BRN

BASEBOARD

AND ADHESIVE

Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

Sue Ferrario (51) mailto:saintlouislab@emsl.com

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804605

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/18/08 4:50 PM

08-14529 VAMC Reinspection JC Building 7

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/18/2008Analysis Date:

Report Date: 9/19/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-7-01-M-106-

005A adhesive 390804605-0005A

BRN

BASEBOARD

AND ADHESIVE

Yellow None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-7-01-F-103-

006A floortile 390804605-0006

WHT 12X12 FT

W/BLK MASTIC

White None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-7-01-F-103-

006A adhesive 390804605-0006A

WHT 12X12 FT

W/BLK MASTIC

Black None Detected

Non-Fibrous

Heterogeneous

Cellulose9% Non-fibrous (other)91%

JC-7-01-M-103-

007A covebase 390804605-0007

BRN

BASEBOARD

AND ADHESIVE

Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-7-01-M-103-

007A adhesive 390804605-0007A

BRN

BASEBOARD

AND ADHESIVE

Yellow None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-7-01-M-102-

008A covebase 390804605-0008

BRN

BASEBOARD

AND ADHESIVE

Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-7-01-M-102-

008A adhesive 390804605-0008A

BRN

BASEBOARD

AND ADHESIVE

Yellow None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804605

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/18/08 4:50 PM

08-14529 VAMC Reinspection JC Building 7

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/18/2008Analysis Date:

Report Date: 9/19/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-7-01-F-21-009A

floortile 390804605-0009

GRN 12X12 FT

W/BLK MASTIC

Green Non-Fibrous

Heterogeneous

Chrysotile6%Non-fibrous (other)94%

JC-7-01-F-21-009A

adhesive 390804605-0009A

GRN 12X12 FT

W/BLK MASTIC

Black Non-Fibrous

Heterogeneous

Chrysotile9%Non-fibrous (other)89% Quartz2%

JC-7-01-F-10-010A

floortile 390804605-0010

GREY 12X12 FT

W/BLK MASTIC

Gray Non-Fibrous

Heterogeneous

Chrysotile9%Non-fibrous (other)91%

JC-7-01-F-10-010A

adhesive 390804605-0010A

GREY 12X12 FT

W/BLK MASTIC

Black Non-Fibrous

Heterogeneous

Chrysotile12%Non-fibrous (other)86% Quartz2%

JC-7-01-M-21-011A

390804605-0011

2X2 CT Various None Detected

Fibrous Heterogeneous

Cellulose28% Min. Wool37%

Non-fibrous (other)7% Perlite28%

JC-7-01-M-7A-

012A covebase 390804605-0012

GREY

BASEBOARD

AND ADHESIVE

Gray None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-7-01-M-7A-

012A adhesive 390804605-0012A

GREY

BASEBOARD

AND ADHESIVE

Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)98% Quartz2%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804605

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/18/08 4:50 PM

08-14529 VAMC Reinspection JC Building 7

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/18/2008Analysis Date:

Report Date: 9/19/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-7-01-F-7A-013A

floortile 390804605-0013

GREY 12X12 FT

W/BLK MASTIC

Gray Non-Fibrous

Heterogeneous

Chrysotile9%Non-fibrous (other)91%

JC-7-01-F-7A-013A

adhesive 390804605-0013A

GREY 12X12 FT

W/BLK MASTIC

Black Non-Fibrous

Heterogeneous

Chrysotile9%Non-fibrous (other)89% Quartz2%

JC-7-01-M-10-014A

390804605-0014

BLK LAB

COUNTERTOP

Black Non-Fibrous Heterogeneous

Amosite<1% Chrysotile19%

Non-fibrous (other)81%

JC-7-01-M-10-015A

390804605-0015

BLK PEG BOARD Black Non-Fibrous Heterogeneous

Chrysotile29%Non-fibrous (other)71%

JC-7-01-T-21-016A

390804605-0016

3" ELBOW, WHT

WRAP, WHT

BLOCK INS

White None Detected

Non-Fibrous Heterogeneous

Fibrous (other)18% Min. Wool27%

Non-fibrous (other)55%

JC-7-01-T-21-017A

390804605-0017

3" HZ, WHT

WRAP, YLW INS

Various None Detected

Fibrous Heterogeneous

Cellulose4% Glass2% Min. Wool86%

Non-fibrous (other)8%

JC-7-01-M-6-018A

390804605-0018

BLK LAB

COUNTERTOP

Black None Detected

Non-Fibrous Heterogeneous

Non-fibrous (other)81% Quartz19%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804605

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/18/08 4:50 PM

08-14529 VAMC Reinspection JC Building 7

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/18/2008Analysis Date:

Report Date: 9/19/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-7-01-M-6-019A

390804605-0019

TRANSITE VENT

HOOD

Gray Non-Fibrous Heterogeneous

Chrysotile19%Non-fibrous (other)81%

JC-7-01-F-6-020A

floortile 390804605-0020

GREY 12X12 FT

W/BLK MASTIC

Gray Non-Fibrous

Heterogeneous

Chrysotile12%Non-fibrous (other)88%

JC-7-01-F-6-020A

adhesive 390804605-0020A

GREY 12X12 FT

W/BLK MASTIC

Black Non-Fibrous

Heterogeneous

Chrysotile12%Non-fibrous (other)88%

JC-7-01-M-102-

021A 390804605-0021

2X4 CT Various None Detected

Fibrous

Heterogeneous

Cellulose28% Min. Wool37%

Non-fibrous (other)7% Perlite28%

JC-7-01-M-108-

022A 390804605-0022

2X4 CT Various None Detected

Fibrous

Heterogeneous

Cellulose28% Min. Wool37%

Non-fibrous (other)7% Perlite28%

JC-7-01-M-108-

023A 390804605-0023

2X4 CT Various None Detected

Fibrous

Heterogeneous

Cellulose28% Min. Wool37%

Non-fibrous (other)7% Perlite28%

JC-7-01-M-16-024A

covebase 390804605-0024

GREY

BASEBOARD

AND ADHESIVE

Gray None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804605

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/18/08 4:50 PM

08-14529 VAMC Reinspection JC Building 7

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/18/2008Analysis Date:

Report Date: 9/19/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-7-01-M-16-024A

adhesive 390804605-0024A

GREY

BASEBOARD

AND ADHESIVE

Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)98% Quartz2%

JC-7-01-F-22-025A

floortile 390804605-0025

GRN 12X12 FT

W/BLK MASTIC

Green Non-Fibrous

Heterogeneous

Chrysotile6%Non-fibrous (other)94%

JC-7-01-F-22-025A

adhesive 390804605-0025A

GRN 12X12 FT

W/BLK MASTIC

Black Non-Fibrous

Heterogeneous

Chrysotile19%Non-fibrous (other)79% Quartz2%

JC-7-01-M-22-026A

390804605-0026

2X2 CT Various None Detected

Fibrous Heterogeneous

Cellulose28% Min. Wool37%

Non-fibrous (other)7% Perlite28%

JC-7-01-M-23-027A

390804605-0027

2X2 CT Various None Detected

Fibrous Heterogeneous

Cellulose28% Min. Wool37%

Non-fibrous (other)7% Perlite28%

JC-7-01-F-22-028A

floortile 390804605-0028

GRN 12X12 FT

W/BLK MASTIC

Green Non-Fibrous

Heterogeneous

Chrysotile6%Non-fibrous (other)94%

JC-7-01-F-22-028A

adhesive 390804605-0028A

GRN 12X12 FT

W/BLK MASTIC

Black Non-Fibrous

Heterogeneous

Chrysotile12%Non-fibrous (other)86% Quartz2%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804605

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/18/08 4:50 PM

08-14529 VAMC Reinspection JC Building 7

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/18/2008Analysis Date:

Report Date: 9/19/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-7-01-M-23-029A

covebase 390804605-0029

GREY

BASEBOARD

AND ADHESIVE

Gray None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-7-01-M-23-029A

adhesive 390804605-0029A

GREY

BASEBOARD

AND ADHESIVE

Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)94% Quartz6%

JC-7-01-M-1A-030A

390804605-0030

SHEETROCK

MUD

White None Detected

Non-Fibrous Heterogeneous

Mica4% Non-fibrous (other)96%

JC-7-01-M-1-031A

390804605-0031

BLK PEG BOARD Black Non-Fibrous Heterogeneous

Amosite<1% Chrysotile19%

Non-fibrous (other)81%

JC-7-01-M-2-032A

390804605-0032

BLK PEG BOARD Black Non-Fibrous Heterogeneous

Amosite<1% Chrysotile19%

Non-fibrous (other)81%

JC-7-01-M-2-033A

390804605-0033

SHEETROCK

MUD

White Non-Fibrous Heterogeneous

Chrysotile<1%Mica4% Non-fibrous (other)96%

JC-7-01-M-19-034A

390804605-0034

SHEETROCK

MUD

White Non-Fibrous Heterogeneous

Chrysotile<1%Mica4% Non-fibrous (other)96%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804605

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/18/08 4:50 PM

08-14529 VAMC Reinspection JC Building 7

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/18/2008Analysis Date:

Report Date: 9/19/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-7-01-T-AT-035A

390804605-0035

4" T, WHT

WRAP, WHT

BLOCK INS

White None Detected

Non-Fibrous Heterogeneous

Fibrous (other)18% Min. Wool27%

Non-fibrous (other)55%

JC-7-01-T-AT-036A

390804605-0036

4" HZ, WHT

WRAP, YLW INS

Various None Detected

Fibrous Heterogeneous

Cellulose4% Glass2% Min. Wool86%

Non-fibrous (other)8%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

THIS IS THE LAST PAGE OF THE REPORT.

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

Certifications