36C25518Q0169-00003003.pdf

PDF 7 MB Posted

Attached to
657-18-1-1582-0008 Asbestos Lead Survey - STL
Solicitation number
36C25518Q0169
Issued by

About this file

36C25518Q0169 00003 08-14529 JC Bldg 3 Report.pdf

View the file

Other files

File Type Posted
36C25518C0113-000.docx DOCX document
36C25518Q0169-00003004.pdf PDF
36C25518Q0169-00003005.pdf PDF
36C25518Q0169-00003007.pdf PDF
36C25518Q0169-00003010.pdf PDF
36C25518Q0169-00003008.pdf PDF
36C25518Q0169-00003000.docx DOCX document
36C25518Q0169-00003002.pdf PDF
36C25518Q0169-00003001.pdf PDF
36C25518Q0169-00003009.pdf PDF
36C25518Q0169-00003006.pdf PDF
36C25518Q0169-00002033.pdf PDF
36C25518Q0169-00002050.pdf PDF
36C25518Q0169-00002031.pdf PDF
36C25518Q0169-00002055.pdf PDF
36C25518Q0169-00002047.pdf PDF
36C25518Q0169-00002053.pdf PDF
36C25518Q0169-00002038.pdf PDF
36C25518Q0169-00002045.pdf PDF
36C25518Q0169-00002039.pdf PDF
36C25518Q0169-00002052.pdf PDF
36C25518Q0169-00002037.pdf PDF
36C25518Q0169-00002032.pdf PDF
36C25518Q0169-00002036.pdf PDF
36C25518Q0169-00002040.pdf PDF
36C25518Q0169-00002043.pdf PDF
36C25518Q0169-00002042.pdf PDF
36C25518Q0169-00002048.pdf PDF
36C25518Q0169-00002028.docx DOCX document
36C25518Q0169-00002054.pdf PDF
36C25518Q0169-00002035.pdf PDF
36C25518Q0169-00002041.pdf PDF
36C25518Q0169-00002058.pdf PDF
36C25518Q0169-00002030.pdf PDF
36C25518Q0169-00002049.pdf PDF
36C25518Q0169-00002046.pdf PDF
36C25518Q0169-00002044.pdf PDF
36C25518Q0169-00002057.pdf PDF
36C25518Q0169-00002029.pdf PDF
36C25518Q0169-00002051.pdf PDF
36C25518Q0169-00002034.pdf PDF
36C25518Q0169-00002056.pdf PDF
36C25518Q0169-00001000.docx DOCX document
36C25518Q0169-004.pdf PDF
36C25518Q0169-002.pdf PDF
36C25518Q0169-001.docx DOCX document
36C25518Q0169-003.pdf PDF
36C25518Q0169-000.docx DOCX document
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS ASSESSMENT

ASBESTOS REINSPECTION REPORT

John Cochran Division 915 North Grand Boulevard

St. Louis, Missouri

Building 3

Prepared for:

St. Louis V. A. Medical Center 915 North Grand Boulevard

St. Louis, Missouri

Prepared by:

1421 Clarkview Road, Suite 100 P. O. Box 17867 Baltimore, MD 21209 Shreveport, Louisiana 71138-0867

(888) 776-0670 (318) 687-3771

INTRODUCTION

2008 ASBESTOS REINSPECTION REPORT

ST. LOUIS V. A. MEDICAL CENTER

JOHN COCHRAN AND JEFFERSON BARRACKS DIVISIONS

SCOPE OF WORK

1. The Inspector and Management Planner reviewed prior inspections and Management Plan information on file and compared this information with existing conditions for each facility.

2. This asbestos reinspection complies with the requirements of Asbestos Hazard Emergency Response Act (AHERA).

3. Each facility inspection was performed by an accredited inspector.

4. For each facility, the inspector performed the following tasks:

a. Visually reinspected and reassessed the condition of all friable known or assumed

ACBM.

b. Visually inspected material that was previously considered non-friable Asbestos- Containing Building Material (ACBM) and touched the material to determine whether it has become friable since the last inspection.

c. Identified any homogeneous areas with material that has become friable since the last inspection or reinspection.

d. The inspector collected bulk samples for analysis of newly friable material that is already assumed (not sampled) to be ACBM or collected additional bulk samples to fully assess the suspect materials.

e. Visually inspected, sampled, analyzed, and assessed the conditions of building materials that have been added to the facility since the last inspection or reinspection.

f. Assessed the condition of the newly friable material in areas where samples were collected and of newly friable material in areas assumed to be ACBM.

g. Reassessed the condition of friable known or assumed ACBM previously identified.

h. Recorded above information on field inspection forms for each facility.

5. A Management Planner reviewed the above information and performed the following required functions:

a. Reviewed each Management Plan for compliance with AHERA and verified that the plan reflects current conditions.

b. Reviewed the results of each reinspection and assessment.

c. Recommended in writing, the appropriate response actions.

d. Signed and dated the review documents, included the accreditation number of inspectors and planners, and submitted a copy to the Designated Person.

6. The following information was submitted to the Designated Person under AHERA, for inclusion in the Management Plan for each facility and, optionally, at a central office location.

a. The date of the inspection, the name and signature of the person making the inspection, state of accreditation, his or her accreditation number, and any changes in the condition of known or assumed ACBM.

b. If samples were collected, the exact locations where samples are collected during the inspection, a description of the manner used to choose sampling locations, the name and signature of each accredited inspector who collected the samples, state of accreditation, and his or her accreditation number.

c. Any assessments or reassessments made of friable material, the name and signature of the accredited inspector making the assessments, state of accreditation, and his or her accreditation number.

MANAGEMENT PLAN RECOMMENDATIONS

The following general notes are for all facilities inspected during the Asbestos Reinspection.

These notes reference any deficiencies found in prior inspections, reinspections, and the current Management Plan.

1. Removal Priorities were developed for each homogeneous area. The Removal Priorities are an indicator of priorities for future repair work or abatement work to be scheduled as financial budgets allow. Please see the 2008 Reinspection Condition and Removal Priority Table for further detail.

2. The current condition of material was listed for each homogeneous area. The condition, location, and potential for disturbance factors are used for the hazard ranking. Please see the 2008 Reinspection Condition and Removal Priority Table for the condition summaries.

3. Records for custodial, janitorial, and maintenance staff who have received two-hour awareness training should be filed in the Management Plan.

4. Any new custodial, janitorial, or maintenance staff that have the potential to come in contact with asbestos-containing materials (ACM) are required to attend a two-hour awareness training class. Records of training for new employees should be filed in the Management Plan.

5. The Designated Person is required to inform workers and building occupants at least once a year about the Management Plan. This includes information about inspections, response actions, and post-response action activities that are planned or in progress.

Provide a copy of the notification to each facility and include a copy in the Management Plan.

6. Maintenance areas (boiler rooms, janitor closets, etc.) are required to have warning labels where ACM are located. Install warning labels in these areas as needed. Some older labels may have come loose and are no longer visible. Post the labels in a prominent location.

7. Review the enclosed 2008 Reinspection Condition and Removal Priority Table for maintenance actions that may be required and to establish priorities and budgets for future repair and abatement work.

8. Periodic “Surveillance Inspections” are required every six (6) months. This inspection should indicate the condition of the material and provide recommendations for repair or potential removal. Consistency of inspections is desired and, therefore, should be performed by the same individual(s) for all facilities. An accredited inspector is not required, but is recommended. Records of Surveillance Inspections should be filed in both the administrative and facility Management Plans.

9. ”Reinspections” are required every three (3) years. Updated information should be added to the Management Plan.

10. The existing Management Plan (original) is updated by this Three-Year Reinspection.

All procedures and methods listed in the Plan are still in effect and should be followed unless specifically updated or omitted by this inspection. This includes maintenance procedures, repairs to damaged material, response actions, record keeping, surveillance inspections, and training.

11. An accredited “Supervisor” should be on staff or available on a contract basis per AHERA guidelines. Certification paperwork should be filed in the training section of the Management Plan.

12. ACBM should only be removed by licensed and accredited contractors in the State of Missouri. Response actions related to abatement activity should be filed in the Management Plan. Removal of limited amounts of asbestos is within the scope of the Management Plan by the accredited Supervisor and trained individuals.

13. Notification should be provided to “outside contractors” about ACM within the facility.

This should include such trades or services as telephone, electrical, plumbing, air conditioning, and other construction work. A form should be created for this purpose and placed in the Management Plan.

14. New building construction and portable buildings added to a facility are required to be inspected and sampled for ACM. In lieu of this, a letter from the architect, engineer, or manufacturer can be obtained that states “no ACM were specified or used in the facility”.

A copy of this letter is to be filed with the Management Plan at the facility. This letter will cancel the requirement for sampling.

15. Abatement Costs were developed for each homogeneous area and per facility. The estimated abatement cost is for budget purposes only. The cost is based on the area of material and estimated abatement costs for this material. The cost is for abatement only and does not include abatement design, air monitoring, or project observation costs.

REPORT SECTION

This report includes the following sections:

ACM Homogeneous Areas Summary Table and Drawings

This section provides a quick table reference to all asbestos-containing homogeneous areas found during the reinspection and drawings with the asbestos-containing homogeneous areas found during the 2008 asbestos reinspection.

Condition and Removal Priority Table

This section provides a table with the current condition, potential for disturbance, and removal priority for each homogeneous area.

Master Summary Table – Asbestos Bulk Samples

This table provides a listing of all asbestos bulk samples taken to date.

Asbestos-Containing Bulk Samples

This table provides a listing of all asbestos-containing bulk samples.

2008 Reinspection – Inspection Logs

This section provides the field inspection logs for samples taken during the 2008 asbestos reinspection.

Bulk Sample Location Drawings

This section provides drawings with sample locations for all asbestos bulk samples.

2008 Reinspection – Photographs

This section provides photographs of all asbestos bulk samples taken during the 2008 asbestos reinspection.

2008 Reinspection – Laboratory Reports

This section provides all laboratory analytical results.

Certifications

This section provides certifications for all Inspectors, the Management Planner who reviewed this Management Plan, and the laboratory that performed the bulk sample analysis.

Periodic Surveillance Forms

This section includes the forms completed during the periodic surveillance inspections required every six (6) months.

Management Plan Updates

This section includes the records of any asbestos abatement activities that are completed at the subject site. Notifications, daily notes, drawings, etc., should be placed in this section. This would also include air-monitoring data from asbestos abatement projects.

Response Actions

This section includes the records of any internal asbestos abatement or operation and maintenance activities that may be completed by V. A. employees. This would include any drawings, field notes, and air monitoring that was completed.

Training Documents

This section includes the records of training for the Designated Person and accredited Supervisor, as well as the two-hour awareness training for the custodial, janitorial, and maintenance staff.

Annual Notification Letters

This section includes copies of the annual Notification Letters provided to employees to inform them of the availability of the Management Plan.

Initial Inspection

This section contains the original asbestos inspection that was completed in 1994. This information was used to develop the 2008 Asbestos Reinspection.

CONTRACTORS

This 2008 Asbestos Reinspection was provided by:

Contractor: Subcontractor:

FINBACK 670, Inc. ALTEC Environmental Consultants, Inc.

1421 Clarkview Road, Suite 100 10100 Woolworth Road Baltimore, MD 21209 Keithville, LA 71047

(888) 776-0670 (Office) (318) 687-3771 (Office)

(877) 776-0670 (Fax) (318) 687-9923 (Fax)

INSPECTORS:

Brandon Odom Donald R. Joiner LA Certificate No. 9I01392 LA Certificate No. 8I01348 LA Certificate No. 9I01348

Eric Clipps Joshua Anders LA Certificate No. 9I01588 LA Certificate No. 9I01589

Justin L. Holcomb LA Certificate No. 9I00306

MANAGEMENT PLANNER:

Roy W. Dowling LA Certificate No. 9I00213 – Inspector LA Certificate No. 9P00072 – Management Planner

Accreditation Agency: Louisiana Department of Environmental Quality

ACM Homogeneous Areas Summary Table and Drawings

JOHN COCHRAN DIVISION

2008 THREE-YEAR ASBESTOS REINSPECTION

ACM HOMOGENEOUS AREAS SUMMARY TABLE

Floor Flooring Materials Surfacing Materials TSI Materials Miscellaneous Materials

1 HMA-01 12x12 Floor Tile & Adhesive No ACM HMA-03 Pipe Insulation & Fittings No ACM

Floor Flooring Materials Surfacing Materials TSI Materials Miscellaneous Materials

1 HMA-01 12x12 Floor Tile & Adhesive No ACM HMA-03 Pipe Insulation & Fittings HMA-04 Fire Door (Assumed)

Floor Flooring Materials Surfacing Materials TSI Materials Miscellaneous Materials

1 HMA-02 12x12 Floor Tile No ACM No ACM HMA-04 Fire Door (Assumed)

Building 3 - Basement

Building 3 - 1st Floor

Building 3 - 2nd Floor

BASEMENT

ST. LOUIS V.A. MEDICAL CENTER

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI B2 mudded joint fitting on paper wrap 0 5 4.00 B2 paper wrap pipe lagging 18 lf 0 4.00

B3 mudded joint fitting on mag pipe la 0 40 4.00

B5 magnesia pipe lagging 12 lf 0 4.00 B5 mudded joint fitting on mag pipe la 0 2 4.00 B5 mudded joint fitting on paper wrap 0 3 4.00 B5 paper wrap pipe lagging 21 lf 0 4.00

B6 magnesia pipe lagging 175 lf 0 4.00 B6 mudded joint fitting on mag pipe la 0 40 4.00 B6 mudded joint fitting on paper wrap 0 37 4.00 B6 paper wrap pipe lagging 150 lf 0 4.00

376 127

Building 3 - Basement

TOTALS

1ST FLOOR

ST. LOUIS V.A. MEDICAL CENTER

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 103 magnesia pipe lagging 20 lf 0 0.00 103 mudded joint fitting on mag pipe la 0 4 4.00

105E magnesia pipe lagging 20 lf 0 0.00 105E mudded joint fitting on mag pipe la 0 2 4.00

119 mudded joint fitting on paper wrap 0 2 6.00 119 paper wrap pipe lagging 8 lf 0 6.00

132 magnesia pipe lagging 22 lf 0 4.00 132 mudded joint fitting on mag pipe la 0 4 4.00

133 magnesia pipe lagging 20 lf 0 4.00 133 mudded joint fitting on mag pipe la 0 4 4.00

90 16

Building 3 - 1st Floor

TOTALS

2ND FLOOR

Condition and Removal Priority Table

Qualitative Ranking Numerical Rating

Good 8, 9, 10

Fair 4, 5, 6, 7

Poor 1, 2, 3

Physical Disturbance Environmental Disturbance

Low 1, 2, 3

Medium 4, 5, 6, 7

High 8, 9, 10

Qualitative Ranking Numerical Rating High 1, 2, 3

Medium 4, 5, 6, 7

Low 8, 9, 10

1 Qualitative Rankings and Quantitative (Numerical) Ratings for Current Condition

2 Qualitative Rankings and Quantitative (Numerical) Ratings for Potential for Disturbance

Assessment FactorsQualitative Ranking Numerical Rating

Description of Current Condition Surfacing material has no visible damage or small amounts of damage; covering on thermal system insulation is intact or has small amounts of damage; miscellaneous materials intact; no visible debris or small amounts of debris.

Address with on-going maintenance procedures

Maintain in good condition

Surfacing material has moderate but not extensive amounts of visible damage; covering on thermal system insulation is cut or torn, exposing moderate but not extensive amounts of insulation; moderate but not extensive damage to miscellaneous materials such as floor tile; moderate but not extensive amounts of visible dust and debris..

3 Qualitative Rankings and Quantitative (Numerical) Ratings for Removal Priority

Description of Current Condition Address short-term

Extensive damage to surfacing material; covering on thermal system insulation is cut or torn extensively and insulation itself is damage; miscellaneous materials such as floor tile extensively damaged and underlying mastic exposed; extensive amounts of dust and debris.

Accessibility: accessibility during normal operations

Activities: activities that people do and how often they do them

Vibration: vibration from operating machinery, HVAC equipment, and so forth

Air/Dust: air currents strong enough to dislodge loose ACM; airborne dust that can erode material

Corrosive: corrosive atmosphere or liquids that can erode the covering or matrix

Water Damage: water damage from leaking roof, pipe or other source

2008 THREE-YEAR ASBESTOS REINSPECTION

CONDITION AND REMOVAL PRIORITY TABLE

Rating Based On Rating Based On

HMA-01 3 Basement 12x12 Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-03 3 Basement Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-04 3 Basement Fire Door (Assumend) No Restricted 10 Intact 1 Maintenance 10

HMA-01 3 1 12x12 Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-03 3 1 Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-04 3 1 Fire Door (Assumend) No Restricted 10 Intact 1 Maintenance 10

HMA-02 3 2 12x12 Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-04 3 2 Fire Door (Assumend) No Restricted 10 Intact 1 Maintenance 10

Homogeneous Area No. Bldg Floor Material Description

Building 3 - 2nd Floor

Removal Priority 3

Building 3 - 1st Floor

Current Condition 1

Building 3 - Basement

Friable Yes/No

Accessibility Yes/No

Restricted

Potential for Disturbance 2

Master Summary Table Asbestos Bulk Samples

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

JC03 00 B6 JC-03-00-M-B6-01 4" beige cove base JC03 00 B6 JC-03-00-M-B3-02 2x4 white w/small dents & worms ceiling tile JC03 00 B6 JC-03-00-M-B6-03 2x4 white/pinholes & worms ceiling tile JC03 00 B4A JC-03-00-S-B4A-04 Off-white hardwall plaster JC03 00 B4A JC-03-00-S-B4A-05 Off-white plaster JC03 00 B4 JC-03-00-S-B4-06 White plaster JC03 00 B4A JC-03-00-M-B4A-07 Gypsum drywall JC03 00 B5 JC-03-00-M-B5-08 Black rubberized duct connector JC03 00 B5 JC-03-00-T-B3-09 Magnesia pipe lagging JC03 00 B5 JC-03-00-T-B5-10 Off-white TSI JC03 00 B6 JC-03-00-T-B6-11 Off-white TSI JC03 00 B3 JC-03-00-T-B3-12 Mudded joint fitting on magnesia pipe lagging JC03 00 B5 JC-03-00-T-B5-13 Gray TSI JC03 00 B6 JC-03-00-T-B6-14 Gray TSI JC03 00 B3 JC-03-00-T-B3-15 Paper wrap pipe lagging JC03 00 B5 JC-03-00-T-B5-16 Brown/gray TSI JC03 00 B6 JC-03-00-T-B6-17 gray TSI JC03 00 B3 JC-03-00-T-B3-18 Mudded joint fitting on paper wrap JC03 00 B5 JC-03-00-T-B5-19 Gray TSI JC03 00 B6 JC-03-00-T-B6-20 Gray/white TSI JC03 01 118 JC-03-01-M-118-01 2x4 white paper w/gray specks ceiling tile JC03 01 102 JC-03-01-M-102-02 2x4 white w/pinholes & specks ceiling tile JC03 01 102A JC-03-01-S-102A-03 Off-white hardwall plaster JC03 01 128 JC-03-01-M-128-04 2x4 white w/pinhole & dents ceiling tile JC03 01 110 JC-03-01-M-110-05 2x4 white/w/small & large pinholes ceiling tile JC03 01 110 JC-03-01-M-110-06 4" brown cove base JC03 01 105D JC-03-01-M-105D-07 4" black cove base JC03 01 132 JC-03-01-M-105D-08 Gypsum drywall panels JC03 01 132 JC-03-01-M-132-09 Green vinyl covered drywall panels JC03 01 110 JC-03-01-M-110-10 Gypsum drywall JC03 02 209 JC-03-02-M-209-01 Green linoleum JC03 02 203 JC-03-02-M-203-02 1x1 white w/uniform hole ceiling tile JC03 02 203 JC-03-02-M-203-03 Mastic on CT-7 ceiling tile JC03 02 202 JC-03-02-M-202-04 2x4 white w/pinholes & dents ceiling tile JC03 02 TC JC-03-02-M-TC-05 4" black cove base JC03 02 216B JC-03-02-S-216B-06 Hardwall plaster JC03 02 TC JC-03-02-M-TC-07 Gypsum drywall JC03 02 203 JC-03-02-M-203-08 2x4 white w/small & large pinholes ceiling tile

JC03 2 203 JC-3-02-S-203-001A Plaster JC03 2 203 JC-3-02-M-203-002A 12x12 ceiling tile, glue dot JC03 2 209 JC-3-02-F-209-003A Green linoleum JC03 2 209A JC-3-02-F-209A-004A Green linoleum JC03 2 219 JC-3-02-F-219-005A Layer 1 - White 12x12 floor tile

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

1994 Initial Asbestos Inspection

2008 Asbestos Reinspection

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JC03 2 219 JC-3-02-F-219-005A Layer 2 - Yellow mastic JC03 2 219 JC-3-02-F-219-005A Layer 3 - Green linoleum JC03 2 219 JC-3-02-F-219-005A Layer 4 - Yellow mastic JC03 2 203 JC-3-02-S-203-006A Plaster JC03 2 203 JC-3-02-S-203-007A Plaster JC03 Roof Roof JC-3-02-S-220-008A Gray flashing and roofing tar JC03 Roof Roof JC-3-02-S-220-009A Gray flashing and roofing tar JC03 Roof Roof JC-3-02-S-220-010A Gray flashing and roofing tar JC03 2 203 JC-3-02-M-203-011A 12x12 ceiling tile, glue dot JC03 2 203 JC-3-02-M-203-012A 12x12 ceiling tile, glue dot JC03 1 127 JC-3-01-F-127-013A Tan 12x12 floor tile, black mastic JC03 1 102 JC-3-01-M-102-014A Painted mud on sheetrock coating JC03 1 109 JC-3-01-F-109-015A Dark tan 12x12 floor tile, black mastic JC03 1 125 JC-3-01-M-125-016A Mud on sheetrock coating JC03 1 125 JC-3-01-F-125-017A Dark tan 12x12 floor tile, black mastic JC03 1 111 JC-3-01-F-111-018A Gray 12x12 floor tile, yellow mastic JC03 1 111 JC-3-01-F-111-019A Gray 12x12 floor tile, yellow mastic JC03 1 114 JC-3-01-F-114-020A Gray 12x12 floor tile, yellow mastic JC03 0 B7 JC-3-00-M-B7-021A Cork ceiling tile, glue dot JC03 0 B6 JC-3-00-F-B6-022A Green 12x12 floor tile, black mastic

Asbestos-Containing Bulk Samples

2008 THREE-YEAR ASBESTOS REINSPECTION

LIST OF ASBESTOS-CONTAINING SAMPLES

Building Floor Room Sample ID Material Description

JC03 00 B5 JC-03-00-T-B3-09 Magnesia pipe lagging JC03 00 B5 JC-03-00-T-B5-10 Off-white TSI JC03 00 B6 JC-03-00-T-B6-11 Off-white TSI JC03 00 B3 JC-03-00-T-B3-12 Mudded joint fitting on magnesia pipe lagging JC03 00 B5 JC-03-00-T-B5-13 Gray TSI JC03 00 B6 JC-03-00-T-B6-14 Gray TSI JC03 00 B3 JC-03-00-T-B3-15 Paper wrap pipe lagging JC03 00 B5 JC-03-00-T-B5-16 Brown/gray TSI JC03 00 B3 JC-03-00-T-B3-18 Mudded joint fitting on paper wrap JC03 00 B5 JC-03-00-T-B5-19 Gray TSI JC03 00 B6 JC-03-00-T-B6-20 Gray/white TSI

JC03 2 219 JC-3-02-F-219-005A Layer 1 - White 12x12 floor tile JC03 1 127 JC-3-01-F-127-013A Tan 12x12 floor tile, black mastic JC03 0 B6 JC-3-00-F-B6-022A Green 12x12 floor tile, black mastic

1994 Initial Asbestos Inspection

2008 Asbestos Reinspection

2008 Reinspection Inspection Logs

Client: Date: September 15, 2008 Location: Inspector(s): Brandon Odom and Eric Clipps Address: 915 North Grand Boulevard, St. Louis, Missouri

Note:

Sample ID Material Description Floor Room Location

JC-3-02-S-203-001A Plaster 2 203 Center of room 203

JC-3-02-M-203-002A 12x12 ceiling tile, glue dot 2 203 Center of room 203

JC-3-02-F-209-003A Green linoleum 2 209 East side of room 209 near roof door

JC-3-02-F-209A-004A Green linoleum 2 209A Northeast corner of room 209A

JC-3-02-F-219-005A Layer 1 - White 12x12 floor tile 2 219 Northeast corner of room 219

JC-3-02-F-219-005A Layer 2 - Yellow mastic 2 219 Northeast corner of room 219

JC-3-02-F-219-005A Layer 3 - Green linoleum 2 219 Northeast corner of room 219

JC-3-02-F-219-005A Layer 4 - Yellow mastic 2 219 Northeast corner of room 219

JC-3-02-S-203-006A Plaster 2 203 North side of room 203

JC-3-02-S-203-007A Plaster 2 203 Northeast corner of room 203

JC-3-02-S-220-008A Gray flashing and roofing tar Roof Roof South side of roof (room 220)

JC-3-02-S-220-009A Gray flashing and roofing tar Roof Roof North side of roof (room 220)

JC-3-02-S-220-010A Gray flashing and roofing tar Roof Roof Northeast corner of roof (room 220)

JC-3-02-M-203-011A 12x12 ceiling tile, glue dot 2 203 North side of room 203

JC-3-02-M-203-012A 12x12 ceiling tile, glue dot 2 203 Northeast corner of room 203

ASBESTOS INSPECTION LOG

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Green = Non ACM (determined by Point Count analysis)

John Cochran Division - Building 3 St. Louis V. A. Medical Center

Client: Date: September 15, 2008 Location: Inspector(s): Brandon Odom and Eric Clipps Address: 915 North Grand Boulevard, St. Louis, Missouri

Note:

Sample ID Material Description Floor Room Location

ASBESTOS INSPECTION LOG

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Green = Non ACM (determined by Point Count analysis)

John Cochran Division - Building 3 St. Louis V. A. Medical Center

JC-3-01-F-127-013A Tan 12x12 floor tile, black mastic 1 127 Southeast corner of room 127

JC-3-01-M-102-014A Painted mud on sheetrock coating 1 102 Southwest corner of room 102

JC-3-01-F-109-015A Dark tan 12x12 floor tile, black mastic 1 109 North side of room 109

JC-3-01-M-125-016A Mud on sheetrock coating 1 125 Northwest corner of room 125

JC-3-01-F-125-017A Dark tan 12x12 floor tile, black mastic 1 125 West side of room 125

JC-3-01-F-111-018A Gray 12x12 floor tile, yellow mastic 1 111 Northwest corner of room 111

JC-3-01-F-111-019A Gray 12x12 floor tile, yellow mastic 1 111 Northeast corner of room 111

JC-3-01-F-114-020A Gray 12x12 floor tile, yellow mastic 1 114 Southeast corner of room 114

JC-3-00-M-B7-021A Cork ceiling tile, glue dot 0 B7 Northeast corner of room B7

JC-3-00-F-B6-022A Green 12x12 floor tile, black mastic 0 B6 Northeast corner of room B6

GOOD = Surfacing material has no visible damage or small amounts of damage; covering on thermal system insulation is intact or has small amounts of damage; miscellaneous materials intact; no visible debris or small amounts of debris. FAIR = Surfacing material has moderate but not extensive amounts of visible damage; covering on thermal system insulation is cut or torn, exposing moderate but not extensive amounts of insulation; moderate but not extensive damage to miscellaneous materials such as floor tile; moderate but not extensive amounts of visible dust and debris. POOR = Extensive damage to surfacing material; covering on thermal system insulation is cut or torn extensively and insulation itself is damaged; miscellaneous materials such as floor tile extensively damaged and underlying mastic exposed; extensive amounts of dust and debris.

Material Category: F = Flooring S = Surfacing T = TSI M = Miscellaneous Friability: F=Friable NF=Non-Friable Condition: Good = 8, 9, 10 Fair = 4, 5, 6, 7 Poor = 1, 2, 3

Red = Asbestos-Containing Material Blue = Non Asbestos-Containing MaterialPlease use the following guidelines when reading this report:

Bulk Sample Location Drawings

BASEMENT

1ST FLOOR

2ND FLOOR

2008 Reinspection Photographs

BUILDING 3

sample does not contain asbestos

JC-3-02-S-203-001A and JC-3-02-M-203-002A JC-3-02-F-209-003A

JC-3-02-F-209A-004A JC-3-02-F-219-005A

sample contains asbestos

JC-3-02-S-203-006A and JC-3-02-M-203-011A JC-3-02-S-203-007A and JC-3-02-M-203-012A

JC-3-02-S-220-008A JC-3-02-S-220-009A

JC-3-02-S-220-010A JC-3-01-F-127-013A

JC-3-01-M-102-014A JC-3-01-F-109-015A

JC-3-01-M-125-016A JC-3-01-F-125-017A

JC-3-01-F-111-018A JC-3-01-F-111-019A

JC-3-01-F-114-020A JC-3-00-M-B7-021A

JC-3-00-F-B6-022A

2008 Reinspection Laboratory Reports

Sample Location Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804540

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/16/08 5:00 PM

08-14529 VAMC Reinspection - JC - Building 3

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/17/2008Analysis Date:

Report Date: 9/17/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-3-02-S-203-

001A 390804540-0001

PLASTER Various None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)86% Quartz14%

JC-3-02-M-203-

002A Ceiling Tile 390804540-0002

12X12 CEILING

TILE W/GLUE

DOT

Various None Detected

Fibrous

Heterogeneous

Cellulose94% Non-fibrous (other)6%

JC-3-02-M-203-

002A Adhesive 390804540-0002A

12X12 CEILING

TILE W/GLUE

DOT

Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)96% Quartz4%

JC-3-02-F-209-

003A Flooring 390804540-0003

GRN LINOLEUM Green None Detected

Non-Fibrous

Heterogeneous

Cellulose26% Non-fibrous (other)74%

JC-3-02-F-209-

003A Adhesive 390804540-0003A

GRN LINOLEUM Green None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-02-F-209A-

004A Flooring 390804540-0004

GRN LINOLEUM Green None Detected

Non-Fibrous

Heterogeneous

Cellulose26% Non-fibrous (other)74%

JC-3-02-F-209A-

004A Adhesive 390804540-0004A

GRN LINOLEUM Green None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

Sue Ferrario (32) mailto:saintlouislab@emsl.com

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804540

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/16/08 5:00 PM

08-14529 VAMC Reinspection - JC - Building 3

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/17/2008Analysis Date:

Report Date: 9/17/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-3-02-F-219-

005A Floortile 390804540-0005

WHT 12X12 FT

W/YLW MASTIC

ON GRN

LINOLEUM

White Non-Fibrous

Heterogeneous

Chrysotile6%Non-fibrous (other)94%

JC-3-02-F-219-

005A Adhesive 390804540-0005A

WHT 12X12 FT

W/YLW MASTIC

ON GRN

LINOLEUM

Yellow None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-02-F-219-

005A Flooring 390804540-0005B

WHT 12X12 FT

W/YLW MASTIC

ON GRN

LINOLEUM

Green None Detected

Non-Fibrous

Heterogeneous

Cellulose26% Non-fibrous (other)74%

JC-3-02-F-219-

005A Adhesive 390804540-0005C

WHT 12X12 FT

W/YLW MASTIC

ON GRN

LINOLEUM

Yellow None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-02-S-203-

006A Plaster 390804540-0006

PLASTER Various None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)85% Quartz15%

JC-3-02-S-203-

006A Adhesive 390804540-0006A

PLASTER Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)96% Quartz4%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804540

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/16/08 5:00 PM

08-14529 VAMC Reinspection - JC - Building 3

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/17/2008Analysis Date:

Report Date: 9/17/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-3-02-S-203-

007A 390804540-0007

PLASTER Various None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)85% Quartz15%

JC-3-02-S-220-

008A 390804540-0008

GREY FLASHING

AND ROOFING

TAR

Gray None Detected

Non-Fibrous

Heterogeneous

Synthetic2% Non-fibrous (other)98%

JC-3-02-S-220-

009A 390804540-0009

GREY FLASHING

AND ROOFING

TAR

Gray None Detected

Non-Fibrous

Heterogeneous

Synthetic2% Non-fibrous (other)98%

JC-3-02-S-220-

010A 390804540-0010

GREY FLASHING

AND ROOFING

TAR

Gray None Detected

Non-Fibrous

Heterogeneous

Synthetic2% Non-fibrous (other)98%

JC-3-02-M-203-

011A Ceiling Tile 390804540-0011

12X12 CT

W/GLUE DOT

Various None Detected

Fibrous

Heterogeneous

Cellulose94% Non-fibrous (other)6%

JC-3-02-M-203-

011A Adhesive 390804540-0011A

12X12 CT

W/GLUE DOT

Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)96% Quartz4%

JC-3-02-M-203-

012A Ceiling Tile 390804540-0012

12X12 CT

W/GLUE DOT

Various None Detected

Fibrous

Heterogeneous

Cellulose94% Non-fibrous (other)6%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804540

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/16/08 5:00 PM

08-14529 VAMC Reinspection - JC - Building 3

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/17/2008Analysis Date:

Report Date: 9/17/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-3-02-M-203-

012A Adhesive 390804540-0012A

12X12 CT

W/GLUE DOT

Brown None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)96% Quartz4%

JC-3-02-F-127-

013A Floortile 390804540-0013

TAN 12X12 FT

W/BLK MASTIC

Tan Non-Fibrous

Heterogeneous

Chrysotile6%Non-fibrous (other)94%

JC-3-02-F-127-

013A Adhesive 390804540-0013A

TAN 12X12 FT

W/BLK MASTIC

Black Non-Fibrous

Heterogeneous

Chrysotile12%Non-fibrous (other)88%

JC-3-02-M-102-

014A 390804540-0014

PAINTED MUD

ON SHEETROCK

COATING

Insufficient Material no JC/spackle in sample submitted

JC-3-02-F-109-

015A Floortile 390804540-0015

DK TAN 12X12

FT W/YLW

MASTIC

Tan None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-02-F-109-

015A Adhesive 390804540-0015A

DK TAN 12X12

FT W/YLW

MASTIC

Yellow None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)91% Quartz9%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804540

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/16/08 5:00 PM

08-14529 VAMC Reinspection - JC - Building 3

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/17/2008Analysis Date:

Report Date: 9/17/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-3-02-M-125-

016A 390804540-0016

MUD ON

SHEETROCK

COATING

White None Detected

Non-Fibrous

Heterogeneous

Mica4% Non-fibrous (other)96%

JC-3-02-F-125-

017A Floortile 390804540-0017

DK TAN 12X12

FT W/YLW

MASTIC

Tan None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-02-F-125-

017A Adhesive 390804540-0017A

DK TAN 12X12

FT W/YLW

MASTIC

Yellow None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-02-F-111-

018A Floortile 390804540-0018

GREY 12X12 FT

W/YLW MASTIC

Gray None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-02-F-111-

018A Adhesive 390804540-0018A

GREY 12X12 FT

W/YLW MASTIC

Yellow None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-02-F-111-

019A Floortile 390804540-0019

GREY 12X12 FT

W/YLW MASTIC

Gray None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-02-F-111-

019A Adhesive 390804540-0019A

GREY 12X12 FT

W/YLW MASTIC

Yellow None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390805162

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 10/13/08 8:00 AM

VAMC Reinspection 08-14529 VAMC Reinspection JC Building 3

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

10/14/2008Analysis Date:

Report Date: 10/14/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-03-02-M-102-

014A 390805162-0001 painted mud on sheetrock coating

Various None Detected

Non-Fibrous

Heterogeneous

Mica4% Non-fibrous (other)77% Perlite19%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

THIS IS THE LAST PAGE OF THE REPORT.

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

Sue Ferrario (1)

PDF created with pdfFactory trial version www.pdffactory.com mailto:saintlouislab@emsl.com http://www.pdffactory.com http://www.pdffactory.com

% Fibrous % Non-Fibrous

Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy

390804576

Attn: Roy W. Dowling ALTEC Environmental Consultants, Inc.

2920 Truly Lane Shreveport, LA 71138

Customer PO:

Received: 09/17/08 4:50 PM

08-14529 VAMC REINSPECTION - JC - BUILDING 3

Customer ID: ALT50

Fax: (318) 687-9923 Phone: (318) 687-3771 Project:

EMSL Order:

EMSL Proj:

9/18/2008Analysis Date:

Report Date: 9/18/2008

EMSL Analytical, Inc.

11040A Lin-Valle Drive, Saint Louis, MO 63123 Phone: (314) 845-8910 Fax: (314) 845-6459 Email: saintlouislab@emsl.com

JC-3-01-F-114-

020A Floortile 390804576-0001

GREY 12X12 FT

W/YLW MASTIC

Gray None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-01-F-114-

020A Adhesive 390804576-0001A

GREY 12X12 FT

W/YLW MASTIC

Yellow None Detected

Non-Fibrous

Heterogeneous

Cellulose2% Synthetic2%

Non-fibrous (other)96%

JC-3-01-M-B7-

021A Cork 390804576-0002

CORK CT

W/GLUE DOT

Tan None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

JC-3-01-M-B7-

021A Adhesive 390804576-0002A

CORK CT

W/GLUE DOT

Tan None Detected

Non-Fibrous

Heterogeneous

Non-fibrous (other)98% Quartz2%

JC-3-01-F-B6-022A

Floortile 390804576-0003

GRN 12X12 FT

W/BLK MASTIC

Green Non-Fibrous

Heterogeneous

Chrysotile9%Non-fibrous (other)91%

JC-3-01-F-B6-022A

Adhesive 390804576-0003A

GRN 12X12 FT

W/BLK MASTIC

Black Non-Fibrous

Heterogeneous

Chrysotile19%Non-fibrous (other)79% Quartz2%

Jeff Siria, Laboratory Manager or other approved signatory

PLM-1

Analyst(s)

THIS IS THE LAST PAGE OF THE REPORT.

Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The above test report relates only to the items tested and may not be reproduced in any form without the express written approval of EMSL Analytical, Inc. EMSL’s liability is limited to the cost of analysis. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analysis performed by EMSL St. Louis (AIHA #102636, NVLAP # 200742-0, CA ELAP #2668)

Sue Ferrario (6)

Certifications