Seed 2_557-20-101 -HME_DR_GM85_Datasheet_v42_230209_FDA.pdf

PDF 1 MB Posted

Attached to
VISN 7 CONSTRUCTION MATOC 36C24726R0026 - SOLICITATION
Solicitation number
36C24726R0026
Issued by

About this file

This document is a technical datasheet for the Samsung GM85 premium digital radiography system. The GM85 is a mobile X-ray system featuring a collapsible column design with dimensions of 1,258 mm length, 555 mm width, and a height range of 1,396 mm to 2,152 mm, weighing 349 kg. The system is available in two high-voltage generator (HVG) configurations: Type A (32 kW) and Type B (40 kW), both supporting kVp settings from 40 to 150 in 1 kV increments and mA ranges from 10 to 500, with exposure times from 1 ms to 10 seconds.

The GM85 includes multiple portable wireless detector options: the S4335-AW and F4335-AW (3,040 × 2,466 pixels), S4343-AW (3,040 × 3,036 pixels), and S3025-AW (2,536 × 2,024 pixels), all featuring Amorphous Silicon TFT with Cesium Iodide scintillators and 16-bit A/D conversion. The system incorporates advanced features including a 4-axis auto blade collimator with LED illumination, S-Vue image processing with protocol-adaptive multi-scale processing and noise reduction, auto cropping, and support for multiple software packages such as SimGrid, bone suppression, auto lung nodule detection, and S-DAP dose tracking. Additional options include wireless hand switches, barcode scanners, RFID readers, and integration capabilities with RIS/HIS/PACS systems. The workstation utilizes an Intel Core i3 processor with 8-16 GB RAM, 1 TB SSD storage, and Microsoft Windows 10, supporting multiple languages and DICOM/JPG export formats.

View the file

Other files

File Type Posted
36C24726R0026 0013.pdf PDF
RFI LOG AMENDMENT 0013_ SEED 1 AND 2.pdf PDF
Seed 2_Project 557-20-101_27 13 23_Comm Optical Fiber Backbone Cabling.pdf PDF
RFI LOG AMENDMENT 0012_ SEED 3.pdf PDF
Seed 2_Project 557-20-101_27 10 00_Update Structured Cabling.pdf PDF
RFI LOG AMENDMENT 0011_ SEED 2 REVISED.pdf PDF
36C24726R0026 0012.pdf PDF
RFI LOG AMENDMENT 0011_ SEED 2.pdf PDF
36C24726R0026 0011.pdf PDF
36C24726R0026 0010.pdf PDF
SEED 1_PROJECT 534-23-910 INFECTION CONTROL RISK ASSESSMENT.pdf PDF
36C24726R0026 0009.pdf PDF
RFI LOG AMENDMENT 0009_SEED 1_ SEED 2_ MATOC RFP.pdf PDF
SEED 1_PROJECT 534-23-910 INFECTION CONTROL DETAILS.pdf PDF
ATTACHMENT 18 - SEED 3 WAGE DETERMINATION TUSKEGEE AL20260078 5 18 2026.pdf PDF
36C24726R0026 0008.pdf PDF
ATTACHMENT 14 - SEED 2_WAGE DETERMINATION GA20260095 05 18 2026.pdf PDF
RFI LOG AMENDMENT 0007_Seed 3 - 619A4-25-102.pdf PDF
36C24726R0026 0007.pdf PDF
Seed 3_ 619A4-25-102 - Correct Egress Door Deficiencies Final Drawings.pdf PDF
RFI LOG AMENDMENT 0006_SEED 2 - Revised.pdf PDF
ATTACHMENT 11 - SEED 1_WAGE DETERMINATION SC20260023 05 18 2026.pdf PDF
Seed 2_557-20-101 - Project Bldg 5 As-Builts.pdf PDF
Seed 2_557-20-101 - Photos_RFI 262 263.docx DOCX document
Seed 3_619A4-25-102 Wage Rates AL20260078 01 02 2026.pdf PDF
Seed 1_534-23-910 SOW Rev1 - Final.pdf PDF
Seed 2_557-20-101 -Typical - Symbia Intevo Bold.pdf PDF
Seed 2_557-20-101 - 2024-06-19_SD Rpt_ GC85A_Physicist Rp.pdf PDF
Seed 2_557-20-101 -GEHC-SP_SIGNA-VOYAGER_8-278F.pdf PDF
Seed 2_557-20-101 -5418654-1EN Rev 22.pdf PDF
Seed 2_557-20-101- CT_GE Revolution Apex spec sheet_brosh.pdf PDF
Seed 2_557-20-101 -HME_DR_GC85A_Datasheet_v43_230316_FDA.pdf PDF
RFI LOG AMENDMENT 0006_SEED 2-557-20-101.pdf PDF
36C24726R0026 0006.pdf PDF
Seed 2_557-20-101 -gehealthcare-brochure_idxa_pdf.pdf PDF
Seed 2_557-20-101 - Zone Valve.jpg JPG image
Seed 2_557-20-101 - Monitors.jpg JPG image
Seed 2_557-20-101 Ultrasound_RS85PrestigeTechSpecv2051RS85145rev01.pdf PDF
Seed 2_557-20-101 -GEHC-SP_REVAPEX_6-120F.pdf PDF
Seed 2_557-20-101 -Cardiac_D-Spect Specs.pdf PDF
Seed 2_557-20-101 -Zone Valve A133-5.jpg JPG image
Seed 2_557-20-101 - Persona RF PREMIUM Brochure Fuji.pdf PDF
Seed 2_557.20-101 - REVIT and CAD Screenshot.docx DOCX document
Seed 2_557-20-101 -GC85A Site planning - Samsung Healthcare.pdf PDF
Seed 2_557-20-101 -Signa Voyager 1_5 MRI.pdf PDF
Seed 2_557-20-101 - VA Radiology - CD100 Final Bid Documents - Combined Set - SIGNED.pdf PDF
Seed 2_557-20-101 -Probe Cabinet specs.pdf PDF
Seed 2_557-20-101 - Med Gas Master Alarm Panel.jpg JPG image
RFI LOG AMENDMENT 0006_MATOC RFP.pdf PDF
RFI LOG AMENDMENT 0005_Seed 1.pdf PDF
Show 40 more

Latest 50 of 92 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PREMIUM DIGITAL RADIOGRAPHY

ACCELERATING

EXPERIENCE

GM85

The New

GM85 Technical Data 3GM85 Technical Data2

Type A Type B

Power (kW) 32 40 kVp 40 ~ 150 (1 kV step) 40 ~ 150 (1 kV step) mA 10 ~ 500 10 ~ 500 mAs 0.1 ~ 500 0.1 ~ 500

Exposure time range From 1 ms to 10 seconds From 1ms to 10 seconds Exposure Parameter Setting @Max. Power Rating

49 kV 400 mA 64 kV 500 mA 80 kV 400 mA 100 kV 320 mA 128 kV 250 mA 150 kV 200 mA

49 kV 400 mA 80 kV 500 mA 100 kV 400 mA 125 kV 320 mA 150 kV 250 mA

Generator frequency* 30 kHz / 50 kHz 30 kHz / 50 kHz

Collimator

Type 4-axis auto blade Light LED Additional Filter 0.1, 0.2, 0.3 mmCu (Auto)

Illuminance > 160 lux Inherent Filteration Over 1.4 mmAl @75kVp Rotation Angle -90 ~ 180° (Total 270°)

ETC Measuring Tape DAP Integration*

* Optional

Speed Max. 5.6 km/h

Soft Driving* Provided

Slope Max. 7 deg

Bumper sensor Provided

Emergency Brake Release Provided

Driving

* The adaptive driving control with sensing the force of user.

* Depending on the HVG type

GM85 GM85

Mechanic

HVG

Column Type Collapsible

Column Height Min. 1,396 mm / Max 2,152 mm

SIZE (W (cm) x L (cm) x H (cm)) 55.5 x 125.8 x 139.6

Weight (kg) 349 Tube Reach (cm) 79.3 ~ 135.5

(Center of column to Focal spot) Focal Spot Range (cm) 55 ~ 203

Column Rotation ±315°

Tube Rotation (arm axis) ±180°

Tube Rotation (tube axis) +90° ~ -30°

Tube

Heat Capacity (kHU) 300

Anode Angle 14°

Focal Spot (mm) 0.6 / 1.2

Anode speed min. 3,200/min (60 Hz)

X-ray heat storage capacity of tube 1,056 kHU (750 kJ)

Battery

Display

Type Li-ion Battery

Input Outlet Free Voltage (100-240VAC, 50/60Hz) Charge Time* Approx. 4 hours

- 200-240VAC < 3 hours

- 100-127VAC < 4 hours

Type Main Sub(THU)

Size 21.5” 7”

Resolution 1,920 x 1,080 (FHD) 800 x 480

Touch Provided Provided

* Depends on capacity of outlet

GM85 Technical Data 5

Description

Wireless Hand Switch Bluetooth or Infrared type

Bar Code Scanner Minimum resolution : typical 3 mil

H-DAP Quality Equivalent Filteration : 0.2mmAL @70kVp

Portable Grid for 4335* SID : 130 cm, 6:1, 85 lp/cm

Portable Grid for 4343* SID : 130 cm, 6:1, 85 lp/cm

Attachable Tether Cable (7M) For Charging & Transferring image from detector to system

LAN Cable (3M) For Transferring image to PACS

Pediatric Cover Design Refer to the design in the brochure RFID Reader RFID badge scan for login (Support 125kHz, 13.56MHz)

(Recommend card type : HID Prox / iCLASS ID) In-bin charging Integrated charging cable for S3025-AW/AWM

AC/DC Adaptor Charging Adaptor for S3025-AW/AWM

Hardware

CPU Intel Core i3

RAM 8G or 16G Storage SSD 1TB

- Image storage capacity S4343-AW : ~ 12,000 images F4335-AW / S4335-AW : ~ 14,000 images S3025-AW : ~ 30,000 images -Hard drive encryption

OS Microsoft Windows 10

Software Image acquisition times* (X-ray exposure to image)

S4343-AW(Tethered) : Preview < 2 sec, Final < 5 sec S4343-AW(Wireless) : Preview < 2 sec, Final < 6 sec F4335-AW / S4335-AW(Tethered) : Preview < 2 sec, Final < 4 sec F4335-AW / S4335-AW(Wireless) : Preview < 2 sec, Final < 5 sec S3025-AW(Wireless) : Preview < 3.5 sec, Final < 6 sec

* It depends on the image processing parameters and wireless condition

Post processing

S-VueTM

- Protocol(Body part) adaptive multi scale image processing

- Advanced noise reduction processing

- Excess contrast reduction processing for minimizing metal artifact

Display functions Window level control, Zoom / Magnifier. Flip / Rotate, Invert, Shutter (Fixed / Auto / Manual) Annotations (Marker / Free text / Arrow / Line / Length / Angle / Cobbs angle / Rectangle / Ellipse) Layout (1×1, 1×2, 2×1, 2×2)

Auto cropping Auto shutter

Auto APR* matching X-ray conditions, Image processing parameters, Marker etc Multi-language English, French, German, Italian, Spanish, Russian, Simplified Chinese, Portuguese, Turkish, Finnish, Swedish, Czech, Polish Dose Report List patient dose information�

Send dose information to a PACS Export to DVD/USB through JPG/DICOM format

GM85

Workstation H/W Optional Items

GM85

* Portable Grid for F4335-AW, S4335-AW, S4343-AW requires additional service parts for combining together

Features

Description

SID Guide Intuitive laser guide helps to align SID

Quick Positioning Moving System forword/backward or rotation CW/CCW by THU button

Pediatric Exposure Management Providing subdivided exposure conditions of child and baby S-AlignTM* Improving alignment of detector and tube by providing the angles of detector and tube Detector charging Charging detector automatically in the cabinet

System status indicating LED Indicating x-ray exposure ready/shot and emergency status

Keyless access Accessing to system with pin code on THU display

Quick Link Easy access to existing RIS/HIS/PACS system in the S-Station

Plug-in exposure Battery system that allows irradiation while being charged

* This feature is only for F4335-AW, S4335-AW, S4343-AW detector

* Anatomical Programmed Radiography

1) There are restrictions on sharing between detectors, please refer to separate guide.

S/W Optional Items

Description SimGridTM Enhancing the visibility of image without physical grid by compensating the decrease in contrast caused by scatter radiation Bone Suppression Improving the clarity of soft tissues by suppressing the appearance of bones in chest images

Auto Lung Nodule Detection ALND helps users find lung nodules on x-ray Chest PA images.

S-Enhance Enhancing visibility of foreign body in chest, abdomen and l-spine images

Remote View Transferring configured image through a web browser using the IP address

Manual Stitching Allow manual stitching of multiple images

QAP Package Quality Assurance Program and Al Filter/Phantom

S-DAP Software DAP(Dose Area Product)

S-ShareTM1 Sharing detectors between GM85 and Samsung DR system WBS Activation Support verified wireless barcode scanner

- Refer to the verified scanner list

- Interface(Host/Wireless Scanner) : USB Serial/Bluetooth(2.4GHz-2.5GHz, ISM)

Value-up Package Image Auto Rotation / Additional Patient Information / Prior Exam Review / S-Align™ Info.

To DICOM / Detector Connection Alarm / Bariatric Exposure Management / Easy Protocol Management / Smart Crop Management

Mirror View Provide secured screen sharing of S-Station to the display device using Wi-Fi CERTIFIED Miracast™

GM85 Technical Data 7GM85 Technical Data6

GM85

AccE Detector AccE Detector

GM85

Wireless Portable Detector

Detector model S4335-AW

Detector type Amorphous Silicon TFT / Cesium Iodide scintillator (CsI)

Dimensions 460 x 384 x 15 mm

Active detector matrix (Effective Pixel matrix) 3,040 × 2,466 pixels

Effective area 425.60 mm × 345.24 mm

Pixel pitch 140 ㎛

A/D conversion (Pixel depth) 16 bits

Spatial resolution 3.57 lp/mm

Detective Quantum Efficiency (DQE) 76% (0.0 lp/mm, Typical)

Modulation Transfer Function (MTF) 86% (0.5 lp/mm, Typical)

Installation Wireless / Tethered

Image Acquisition Tethered / Wireless (802.11 a/b/g/n & ac) @2.4/5 GHz

AED Available, v3.0

Weight Approx. 3 kg Max.load capacity 400 kg for uniform load, 200 kg for local load (40 mm in diameter disk at the center) Max.bend capacity > 200 kg @ 3-point bending condition

Dust/Water-resistance IP54

Self diagnosis Automatic detection & alarming of line artifact

Shock logging Real-time detection, logging and alarming of shock level

Battery charging time Typ. 6 hrs. (tethered), Typ. 3 hrs. (battery charger) Battery Operation Time 500 images for 4 hrs.

Waiting for more than 10 hrs under deep sleep mode

Wireless Portable Detector

Detector model S3025-AW

Detector type Amorphous Silicon TFT / Cesium Iodide scintillator (CsI)

Dimensions 350 x 287 x 15 mm

Active detector matrix 2536 x 2024 pixels (W x H)

Effective area 314.5 mm × 251.0 mm (W x H)

Pixel pitch 124 ㎛

A/D conversion (Pixel depth) 16 bits

Spatial resolution 4.0 lp/mm

Detective Quantum Efficiency (DQE) 75% (0 lp/mm, Typical)

Modulation Transfer Function (MTF) 87% (0.5 lp/mm, Typical)

Installation Wireless only

Image Acquisition Wireless (802.11 n/ac) @2.4/5 GHz

AED N/A

Weight 2.1 kg (Typical)

Max.load capacity 400 kg for uniform load, 200 kg for local load (40 mm in diameter disk at the center)

Dust/Water-resistance IP67

Self diagnosis Automatic detection & alarming of line artifact Shock logging Real-time detection, logging and pop-up alarming Battery charging time 2 hrs. (AC-DC adaptor)

Battery Operation Time 270 images for 7.5 hrs

Wireless Portable Detector

Detector model F4335-AW

Detector type Amorphous Silicon TFT / Cesium Iodide scintillator (CsI)

Dimensions 460 x 384 x 15 mm

Active detector matrix (Effective Pixel matrix) 3,040 × 2,466 pixels

Effective area 425.60 mm × 345.24 mm

Pixel pitch 140 ㎛

A/D conversion (Pixel depth) 16 bits

Spatial resolution 3.57 lp/mm

Detective Quantum Efficiency (DQE) 76% (0.0 lp/mm, Typical)

Modulation Transfer Function (MTF) 86% (0.5 lp/mm, Typical)

Installation Wireless / Tethered

Image Acquisition Tethered / Wireless (802.11 a/b/g/n & ac) @2.4/5 GHz

AED Available, v3.0

Weight Approx. 2kg (w/o Battery Set*) Max.load capacity 400 kg for uniform load, 200 kg for local load (40 mm in diameter disk at the center) Dust/Water-resistance IP54

Self diagnosis Automatic detection & alarming of line artifact

Shock logging Real-time detection, logging and alarming of shock level

Battery charging time Typ. 6 hrs. (tethered), Typ. 3 hrs. (battery charger) Battery Operation Time 500 images for 4 hrs.

Waiting for more than 10 hrs under deep sleep mode

*The Battery Set includes the battery and the battery cover

Wireless Portable Detector

Detector model S4343-AW

Detector type Amorphous Silicon TFT / Cesium Iodide scintillator (CsI)

Dimensions 460 x 460 x 15 mm

Active detector matrix (Effective Pixel matrix) 3,040 × 3,036 pixels

Effective area 425.60 mm × 425.04 mm

Pixel pitch 140 ㎛

A/D conversion (Pixel depth) 16 bits

Spatial resolution 3.57 lp/mm

Detective Quantum Efficiency (DQE) 76% (0.0 lp/mm, Typical)

Modulation Transfer Function (MTF) 86% (0.5 lp/mm, Typical)

Installation Wireless / Tethered

Image Acquisition Tethered / Wireless (802.11 a/b/g/n & ac) @2.4/5 GHz

AED Available, v3.0

Weight Approx. 3.6 kg Max.load capacity 400 kg for uniform load, 200 kg for local load (40 mm in diameter disk at the center) Max.bend capacity > 200 kg @ 3-point bending condition

Dust/Water-resistance IP54

Self diagnosis Automatic detection & alarming of line artifact

Shock logging Real-time detection, logging and alarming of shock level

Battery charging time Typ. 6 hrs. (tethered), Typ. 3 hrs. (battery charger) Battery Operation Time 500 images for 4 hrs.

Waiting for more than 10 hrs under deep sleep mode

GM85 Technical Data 9GM85 Technical Data8

Mechanical Specifications Collapsible column type

GM85

Length Width Height Weight

1,258 mm 555 mm Minimum 1,396 mm Maximum 2,152 mm 349 kg

Samsung Electronics Co., Ltd. inspires the world and shapes the future with transformative ideas and technologies, redefining the worlds of TVs, smartphones, wearable devices, tablets, cameras, digital appliances, printers, medical equipment, network systems, and semiconductor and LED solutions. We are also leading in the Internet of Things space through, among others, our Smart Home and Digital Health initiatives.

We employ 307,000 people across 84 countries with annual sales of US $196 billion. To discover more, please visit our official website at www.

samsung.com and our official blog at global.samsungtomorrow.com

GM85 Datasheet v4.2-230209-EN

ⓒ 2022 Samsung Electronics All rights reserved.Samsung Electronics reserves the right to modify the design, packaging,specifications, and features shown herein, without prior notice or obligation.

File details come from the government source that posted it. Updated .