2.1.1 Attachment 3 - 2BR Cal Wildfire NextGen CAD Drawings HVAC Wall Mounted - FEB-03-2025 PE Sealed.pdf
PDF 7 MB Posted
- Solicitation number
- 70FB8025R00000018
- Issued by
-
Federal Emergency Management Agency
About this file
This file contains detailed technical drawings for a FEMA Manufactured Housing Unit (MHU) NextGen 2 Bedroom Unit with a wall-mounted HVAC packaged system, specifically designed for Wildland-Urban Interface Fire Area Construction. The 14-foot wide housing unit is part of FEMA's emergency housing solution, with comprehensive design specifications covering structural, electrical, HVAC, roofing, and tiedown systems.
The drawings, dated February 3, 2025, include precise technical details such as floor plans, wall framing, roof construction, electrical layouts, and chassis specifications. Key design features include 2x6 nominal SPF wall framing, R-19 insulation, 7/16" OSB sheathing, LP SmartSide paneling, a 1.5-ton HVAC package system, and tiedown systems compliant with Wind Zone 1 requirements. The unit is engineered to meet various building codes, including HUD standards, California Residential Code, and specific wildfire exposure construction methods, making it suitable for emergency housing in fire-prone regions.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MANUFACTURED HOUSING UNIT
FEDERAL EMERGENCY MANAGEMENT AGENCY
NEXT GEN 2 BEDROOM UNIT
(HVAC WALL MOUNTED PACKAGED SYSTEM)
APPENDIX D
Wildland - Urban Interface Fire Area Construction
Designs for NextGen 14' Wide MHU's
February 3, 2025
TITLE:
1/8" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DRAWING NO.DATE:
SCALE:
COMPANY: VERSION:
D-14B2-1.1COVER PAGE 14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
REV 02-03-25. Feb 03, 2025
Attachment 3
APPENDIX D ADDITION/
REPLACEMENT DWG. NO. TITLE
D-14B2-1.1 D-14B2-1.2.1
D-14B2-1.3 GENERAL NOTES
D-14B2-1.4 GENERAL NOTES (CONT)
D-14B2-3 DOOR AND WINDOW SCHEDULE
D-14B2-6
HVAC DESIGN AND OVERHEAD DUCT LAYOUTD-14B2-9
D-14B2-10
FRONT SHEARWALL FRAMING AND EXTERIOR SHEATHING
ROOF SHEATHING LAYOUT
D-14B2-18.1
D-14B2-19 D-14B2-20
ROOF OVERHANG DETAIL
D-14B2-22 D-14B2-23
TRANSIT PROTECTION DETAILSD-14B2-27
COVER PAGE
ADDITION/REPLACEMENT PAGE INDEX
ELECTRICAL PLAN
ELEVATIONS
FRONT DOOR SIDEWALL
BACK DOOR SIDEWALL
ADDITION/REPLACEMENT INDEX
D-14B2-18.2 REAR SHEARWALL FRAMING AND EXTERIOR SHEATHING
D-14B2-2 FLOOR PLAN
D-14B2-11.1 CHASSIS
D-14B2-17.1-17.2 ENDWALL FRAMING AND INTERIOR SHEATHING
ROOF FRAMING LAYOUTD-14B2-21
TIE DOWN SYSTEMD-14B2-29.1
RESERVEDD-14B2-29.2
EXISTING FEMA
DWG. NO.
14B2-1.1
NONE
14B2-1.3
NONE
14B2-3 14B2-6 14B2-9 14B2-10
14B2-18.1
14B2-19 14B2-20
14B2-22 14B2-23 14B2-27
14B2-18.2
14B2-2
14B2-11.1
14B2-17.1-17.2
14B2-21
14B2-29.1
14B2-29.2
APPENDIX D FOR WILDLAND - URBAN INTERFACE FIRE AREA CONSTRUCTION IS A SUPPLEMENT TO FEMA'S
STANDARD DRAWING PACKAGES.
APPENDIX D IS INTENDED TO ADD OR REPLACE EXISTING PAGES IN FEMA'S STANDARD DRAWING PACKAGES. THE ADDITION/REPLACEMENT INDEX BELOW IS TO BE USED IN ADDING AND REPLACING PAGES.
D-14B2-11.1.114B2-11.1.1
D-14B2-29.1.114B2-29.1.1
ALT. CHASSIS (95.5" I-BEAM SPACING)
ALT. TIE DOWN SYSTEM (95.5" I-BEAM SPACING)
TITLE:
1/8" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DRAWING NO.DATE:
SCALE:
COMPANY: VERSION:
D-14B2-1.2.114' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
ADDITION/REPLACEMENT PAGE INDEX
REV 04-30-21
. Feb 03, 2025
MANUFACTURED HOUSING UNIT
FEDERAL EMERGENCY MANAGMENT AGENCY
GENERAL NOTES
CODES AND STANDARDS
Manufactured Home Construction and Safety Standards 24 CFR 3280 Manufactured Home Procedural and Enforcement Regulations 24 CFR 3282 Uniform Federal Accessibility Standards (UFAS) Standard for the Installation of Sprinkler Systems in Manufactured Homes (NFPA 13D) Referenced 2005 National Electrical Code (NFPA 70) Articles as Incorporated in HUD 24 CFR 3280 2019 California Residential Code - Section R337 Materials and Construction Methods for Exterior Wildfire Exposure California Air Resources Board Phase 2 (CARB 2) Compliance
STRUCTURAL LOADS
Floor Live Load 40 PSF Floor Dead Load 10 PSF Roof Live Load 40 PSF Roof Dead Load 10 PSF Comply with Wind Zone 1 Requirements of 24 CFR 3280 Wood Roof Diaphragm Wall Height: 7'-6"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-1.3
DRAWING NO.
GENERAL NOTES 14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-1.4
DRAWING NO.
GENERAL NOTES (CONT) 14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
REV 4-27-20
R
EF
ER
3060-E-SG
SEAT
W/H
30603060
BA
TH
1 BEDROOM #1
TPS
CLOSET
D R
YE
R
W
AS
H
ER
3060-E-SG
PANTRY
KITCHEN
BEDROOM #2
1 2
31 2
91 2
1 2
1 2
1 2
91 2
1 2
1 2 31 2
5'-7"
2" 21'-01
2"
2" 4'-9"
2"
8'-0"
2" 7'-31
2"
8'-2"
2" 21 2"
5'-21 2"
2"
1'-101 2"
42'-31 2" 7'-91
2"
43'-91 4"
37'-01 2" 31'-43
4" 26'-83 4" 17'-61
4"
36'-41 4" 18'-83
4" 4'-03 4"
2'-41 2"
2"
84.34 SF
85.00 SF
50'-8"
DINING & LIVING
ROOM
16'-0"21'-01 2"42'-31
2"48'-1"
DESIGNATES A 2X4 WALL
SHEARWALLS - WIND ZONE 1
PLFLENGTHNO.
130"1
SIDEWALL HEIGHT = 90"
162" 180
TRUSS HEEL HEIGHT = 9-15/16"
LIGHT AND VENT SCHEDULE
REQUIRED VENTREQUIRED LIGHTROOM TITLE AREA
6.40 S.F.12.80 S.F.LIVING / DINING ROOM 160.00 S.F
3.36 S.F.6.72 S.F.BEDROOM #1 84.00 S.F.
3.40 S.F.6.80 S.F.BEDROOM #2 85.00 S.F.
160.00 SF
'-6
6"
6"
18'-6"
SHEAR WALLS FOR WIND ZONE 1
HVAC
PACKAGE
SYSTEM
LIVINGDINING
(FIXED)
4 SHELVES
OPTIONAL DEHUMIDIFIER -
SEE APPENDIX A, PAGE A-35.
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-2
DRAWING NO.
FLOOR PLAN 14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
REV 11-15-23
Floor Plan Notes:
1. All bedroom closet shelving shall be 12 inches deep.. Feb 03, 2025
ER
3060-E-SG
SEAT
W/H
30603060
BA
TH
1 BEDROOM #1
TPS
CLOSET
D R
YE
R
W
AS
H
ER
3060-E-SG
PANTRY
KITCHEN
BEDROOM #2
DINING & LIVING
ROOM
D1
D3
D1
D1
D2
D2
D2 D3
D3
MARK
D1 D2 D3
WIDTH
3'-0" 3'-0" 2'-0"
HEIGHT
6'-8" 6'-8" 6'-8"
THICKNESS
1-3/8" 1-3/8" 1-3/8"
TYPE
Outswing Door Hallway Doors Closet & W/H Doors
DOOR SCHEDULE
MARK
W1 W2
WIDTH
2'-6" 2'-6"
HEIGHT
5'-0" 2'-3"
TYPE
Single Hung Window Fixed Pane Window
WINDOW SCHEDULE
W2 W1
W1 W1W1
TOTAL EXTERIOR DOOR AREA: 64.5 SQ. FT.
TOTAL WINDOW AREA: 57.1 SQ. FT.
HVAC
PACKAGE
SYSTEM
Door Notes
1. Exterior doors shall meet 24 CFR 3280.405 requirements and shall comply with Wind Zone 1 requirements.
2. All exterior doors shall be insulated fiberglass or steel with a maximum
U-Value of 0.33.
3. All doors shall have lever type handles in compliance with UFAS 4.13.9.
4. For additional information on exterior and interior doors see FEMA Additional
Requirements document and Appendix A.
5. Return air grills shall be installed above doors unless the grill will be blocked by the sprinkler system and then may be installed in the door or wall.
6. Door stops shall be installed at all interior and wardrobe doors. Door stops may be installed on the door or the floor baseboard. Door stop finish to match interior hardware finish.
7. All bathroom and bedroom doors shall have a privacy lock. The lock mechanism shall be the button type (UFAS 4.13.9) and located on the inside of the bathroom or bedroom.
8. The water heater compartment side of the water heater access door shall be covered with minimum 5/16 inch thick gypsum board.
9. The closet doors shall be equipped with a passage latchset with lever handle.
10. All interior doors shall have a maximum gap of 1" between the finished floor and the bottom of the door.
11. The exterior surface or cladding of exterior doors shall be of non-combustible material or ignition-resistant material to comply with R-337.8.3 Exterior Doors of the 2019 California Residential Code.
12. 14x4 RAG centered in door with bottom of opening 2 1/2" above floor.
Minimum 20 S.I. of free air return area.
Window Notes
1. Windows shall meet 24 CFR 3280.403 and 3280.404 requirements and shall comply with Wind Zone 1 requirements.
2. Windows shall be double paned, low E with vinyl frame. Windows shall have a maximum SHGC of 0.30 and a maximum U-Value of 0.36.
3. Windows shall have a design pressure rating of 15.
4. Windows shall have screens.
5. Exterior windows shall be vinyl frame with minimum one tempered pane and comply with R-337.8.2.1 Exterior Windows of the 2019 California Residential Code.
LIVINGDINING
SEE NOTE 12
(FIXED)
4 SHELVES
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-3
DRAWING NO.
DOOR AND WINDOW SCHEDULE 14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
REV 11-29-21
ER
SEAT
W/H
D R
YE
R
W
AS
H
ER
PANTRY
SS
S3 S3GFCI-WP
S3
TV
SS
19-GFCI
SC
7-GFCI
SSS
Back box for exterior alarm.
S14
GFCI
GFCI
GFCI
GFCI
GFCI
GFCI
RH-16
SS
WP-16
S 3
S 3
TV
SC
FE
T
GFCI-WP
GFCI
TV17
HVAC
PACKAGE
SYSTEM
Single outlet recept for refrigerator
NOAA
18" AFF TO
RECEPTACLE SCREW
44" AFF
S 3
NOAA
18" AFF TO
RECEPTACLE SCREW
44" AFF
S
WP-16
GFCI-WP
(FIXED)
4 SHELVES
19 GFCI-WP
H.T. UNDER FLOOR
SEE NOTE 25
SC 15
S
See Appendix A, A-51, Elevation 2 for exact location of light, light switch and receptacles.
S
TPS Annunciator Panel
TITLE:
1/8" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
Cir. Purpose Type Wire Size Amps Pole
Bedroom 1 14-2 15 1 2 Bedroom 2 15 1
4 Kitchen 20 1 5 Kitchen 1 6 Ext. Recep 1 7 Washer 1 8 Dryer 30 2 9 Electric Range
10 Water Heater 11 Package System 12 15 1 13 Reserved
GFCI
14-2
12-2
10-3 Per MFR. Specs.
14-3
20GFCI 12-2
20GFCI 12-2
20GFCI 12-2
Per MFR. Specs.
Per MFR. Specs.
14 Living Room 15 114-2 15 TPS System 16 Lights/Recep 15 114-2 17 Dining Room 20 1 18 Refrigerator 1
Per MFR. Specs.
Per MFR. Specs.
19 Bath Receps / Heat Tape 20 1
GFCI
GFCI
D-14B2-6
DRAWING NO.
ELECTRICAL PLAN
N/A - --
12-2 2012-2
12-2
14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
Smoke Alarm/C.O.
Electrical And Lighting Notes
1. The highest breaker in the panel box should be 48" maximum. Panel box bottom must be at least 24" from the floor.
2. The light bulbs shall be LED, equivalent to 60-watt incandescent bulbs, minimum 800 lumens, white in color, between 2,700 K and 4,100 K.
3. No glass shall be used in any of the lighting globes.
4. The exterior lights shall be stored in the refrigerator during transport.
5. Interconnected smoke alarms shall utilize the home's primary power source and shall have battery backup.
6. The center line of the switches and the top of the thermostat must be installed at no more than 48” above the finished floor.
7. Electrical outlets must be no lower than 18" above the floor to the center of the receptacle screw.
8. The junction box for the telephone and cable shall be located within 4' of the road side rear of the MHU.
9. Electric wiring may be done either through the floor or the ceiling.
10. Listed service entrance conduit, sized per 2005 NEC, shall be run from the main distribution panel straight down and extend below the bottom board no more than 3 inches with a listed threaded fitting. End of conduit shall be capped.
11. Thermostat wire shall be run with the condenser line set and shall be supported at 48" O.C. with zip ties. Installation shall conform to low voltage wire requirements per 2005 NEC.
12. For additional information on optional dehumidifier wiring requirements see Appendix A, page A-35.
13. Circuit breaker, wire and junction box shall be installed at the plant. Junction box shall be located below wall framing for dehumidifier and cover plate facing into the Living Room, wire nut end of dehumidifier wire in junction box.
14. Bathroom exhaust fan with light to be 75 cfm with an integrated timer. Bath exhaust fan(s) after being turned on, shall run for a minimum of 60 minutes, even if the fan switch is turned off. Any over-ride to the minimum 60-minute requirement is not acceptable. Label with note shall be placed above bath fan switch stating, FAN ON TIMER AND SHUTS OFF AFTER 60 MINUTES.
15. Kitchen range hood exhaust fan with a white light shall be a minimum 100 cfm exhaust fan, with separate switches.
16. Bathroom and kitchen exhaust fans shall vent directly to the outside.
17. Ceiling lights shall have 2 LED bulbs.
18. The bathroom vanity light shall be wall mounted with 3 LED bulbs.
19. The circuit breaker(s) providing power to the TPS unit shall be equipped with a UL-listed locking device that can secure the breaker(s) in the ON position. Devices shall be installed set to the ON position.
20. Kitchen countertop receptacles and switches must be furred out to be 24" (max) from front edge of countertop, and no more than 44" to the top of the switches or receptacles above finished floor.
21. See TPS closet and TPS closet elevations for electrical locations in Appendix A.
22. Heat tape recept located within 24" of water inlet.
23. Smoke alarms shall not be located within 3 feet horizontally from any ceiling discharge grille.
24. Carbon Monoxide Alarms shall be approved and listed by the State of California Fire Marshal per California Information Bulletin 2012-03 (MH) - 06-26-2012.
25. HVAC electrical connection shall be routed through the back of the unit using the knockouts provided by the manufacturer. Running the electrical connection in conduit exposed to the exterior is not acceptable.
Electrical wiring shall not be installed within the plenum used for environmental air (wall mounted curb).
S
WP
Sym. Description
110 volt duplex recep-wall mounted 110 volt duplex-GFCI protected recept
220 volt recept-wall mounted Light Fixture - Ceiling Mounted Light Fixture - Wall mounted Exhaust fan - Light Combo Distribution panel board - 200 amp Exterior light fixture - weather proof
TV
FE
S
S3
NOAA
T
Smoke Alarm w/ Strobe Light - wired in series Telephone Recept TV Outlet Fire Extinguisher Switch Switch - Three Way Outlet for NOAA Weather radio Thermostat
SA
Sym. Description Service Entrance Conduit through bottom board from Main Distribution Panel Board
Optional Dehumidifier (Direct Wired)
20 Optional Dehumidifier 15 114-2GFCI
REV 02-03-25
ER
3060-E-SG
SEAT
W/H
30603060
D R
YE
R
W
AS
H
ER
3060-E-SG
PANTRY SC
SC
16x8 ID
180 CFM
8" FLEX
60 CFM
6" FLEX
100 CFM
8" FLEX
100 CFM
8" FLEX
100 CFM
8" FLEX
110 CFM
6" FLEX
12x8 ID
BATH #1
BEDROOM #1
TPS
CLOSET
KITCHEN
BEDROOM #2 LIVING & DINING
ROOM
2'-6" 11'-7"25'-6"37'-0"
33'-6" 46'-6"
1 2
1 2
1 2
1 2
1 2
1 2
HVAC
PACKAGE
SYSTEM
60 CFM
1 2
4" FLEX
17'-6"
14x30 GRILL
14x30 GRILL W/ FILTER 6'-0"23'-4"
TRANSITION DUCT
(FIXED)
4 SHELVES
14 1/2"x30 1/2"x15" PLENUM
14 1/2"x30 1/2"x15" PLENUM
(1) 16" JUMPER DUCT OR
(2) 12" JUMPER DUCTS
SEE NOTE 15
SC
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-9
DRAWING NO.
OVERHEAD DUCT LAYOUT
HVAC DESIGN AND
HVAC Wall Mounted Package Unit Notes
1. The MHU shall be equipped with a specifically engineered HVAC wall mounted package system based on the size and intended use of the MHU, in accordance with 24 CFR 3280.506, that is compatible with the HVAC wall mounted package system size and capable of maintaining an average temperature of seventy degrees Fahrenheit (70°F) in the MHU.
2. The HVAC wall mounted package system shall not cause vibration within the MHU. The HVAC wall mounted package system shall be mounted in such a way as to dampen the vibrations and any sound that accompany the packaged during operation cycles.
3. The HVAC wall mounted package system shall be able to maintain the temperature based on the coldest average temperature of the operating area of the MHU.
4. The HVAC wall mounted package system will require the manufacturer to have a current Alternative Construction letter from HUD.
5. The HVAC wall mounted package system shall be installed with a curb unit to minimize vibration and sound transmitted to the MHU.
6. A motorized room ventilator shall be installed in the HVAC wall mounted package system.
7. The thermostat shall be designed to work with the HVAC wall mounted package system.
8. The ceiling return air grill located in the bedroom shall accommodate a filter.
9. Duct penetrations thru ceiling board shall be sealed.
10. All vent openings (intake or exhaust) to the exterior of the MHU HVAC wall mounted package system unit or furnace HVAC system shall have noncombustible corrosion-resistant mesh with a minimum of 1/16-inch, but not to exceed 1/8-inch openings, and comply with R337.6 of the 2019 California Residential Code.
HVAC General Notes
1. See FEMA specifications for programable and configurable thermostat requirements.
2. Duct system shall be constructed of class 0 or class 1 circular insulated flex ductwork or equal. All ducts to be insulated with a minimum of R-4 insulation.
3. Metal supply registers shall be 8” x 8” TRUaire A500 series square extruded aluminum ceiling supply register (4-way distribution) with damper OR equivalent.
4. All supply ducts shall be in the roof attic space.
5. All supply duct seams and fasteners shall be sealed with UL-181A or UL-181B listed duct tape.
6. The manufacturer shall provide a duct pressure test report (See FEMA Spec for testing procedure) for each MHU duct system showing duct leakage of 5 percent or less prior to FEMA acceptance of the MHU.
7. No construction debris or sawdust shall be left in the duct system.
8. The main supply and return duct trunks shall be galvanized sheet metal (min. thickness per HUD IB H-1-84) or Johns Manville Mat-face Micro-aire (Type 475 or 800) fiberglass ductboard or equivalent. Duct to be installed per manufacturer's installation instructions.
9. Return air grilles shall be sized per 24 CFR 3280.715(b)(4) - BR #2 only.
10. N/A
11. 14x4 RAG centered in bedroom #2 entry door with bottom of opening 2 1/2" above floor. Minimum 20 S.I. of free air return area.
12. A 12” x 6” return air register shall be located 8” above the floor in the TPS Compartment/ bathroom wall. A register shall be placed on each side of the wall.
13. The manufactured home manufacturer is responsible to assure the wall mounted HVAC unit provided has the following features:
a. Unit is designed to have a ceiling return air system as shown in drawing above. A return air system through the room the unit is in, is not acceptable.
b. Unit is designed so that when unit is operating, and any dampers are open that no direct openings from the outside to the inside of the MHU occur. Standing in the room and being able to see outside through any unit openings is not acceptable.
c. Unit is designed with an anti-vibration curb between the MHU and the wall mounted HVAC unit.
14. Bathroom exhaust fan location shall not be located next to the bathroom supply register.
15. One (1) 16" dia. jumper duct with transition fitting (201 square inches min.) each end or two (2) 12" dia. jumper ducts.
Heating / Cooling
HVAC WALL MOUNTED PACKAGED SYSTEM SPECIFICATIONS
1.5-Ton Package System
Floors 0.0356
Air ducts in ceiling 0.0868
Ceilings and roofs of light color 0.0257
Walls (without windows and doors) 0.0575
U Values Heating
Duct Capacity
Air ducts in ceiling (Duct Area) 281 Sq. Ft.
51,464 Btuh
0.0362
0.0896
0.0258
0.0555
Cooling
14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
REV 11-15-23. Feb 03, 2025
'-6
" M
AX
T O
T O
P O
F R
ID
G
E
VE
N T
14'-0" EAVE TO EAVE
13'-6"
'-6
" M
AX
T O
T H
E
TO
P O
F R
ID
G
E
VE
N T
14'-0" EAVE TO EAVE
13'-6"
HITCH END ELEVATION TAIL END ELEVATION
3"3"3"3"
HUD LABEL: APPROX. 12" UP
FROM FLOOR AND 12" FROM
ROADSIDE.
EXTERIOR RECEPTACLE (GFCI)
EXTERIOR RECEPTACLE (GFCI)
ANGLE RAIN DIVERTER OVER DOOR
EXTERIOR LIGHT
FRONT DOOR
TPS DOOR BACK DOOR
PEEP HOLES
PEEP HOLES
ANGLE RAIN DIVERTER OVER DOOR
EXTERIOR LIGHT
EXTERIOR ALARM DEVICE
BOX w/ COVER PLATE
RIDGE VENT (TYP.)
INTERIOR FLOOR LINE
FRONT DOOR SIDE ELEVATION
BACK DOOR SIDE ELEVATION
RIDGE VENT (TYP.)
SHINGLES COVERED
BY PLASTIC WRAP
OSB FROM BOTTOM OF
SHINGLES TO TOP OF ROOF
RANGE VENT
HITCH END ELEVATION TAIL END ELEVATION
EXTERIOR RECEPTACLE (GCFI)
(6" ABOVE FINISHED FLOOR)
PROTECTIVE COVER
PER FEMA SPEC.
TRANSPONDER
METAL ROOF POD (TYP. 4 PLACES)
METAL ROOF POD (TYP. 4 PLACES)
METAL ROOF POD (TYP.)
ANGLE RAIN DIVERTER
OVER DOOR
DRYER VENT
HOSE BIBB
SPRINKLER DRAIN TPS CLOSET
FLOOR DRAIN
SERVICE ENTRANCE CONDUIT
TITLE:
Scale: 1/8" = 1'-0"
Date: 03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency D-14B2-10
DRAWING NO.
ELEVATIONS 14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
Exterior Finish Notes
1. Siding shall be 19/32” thick LP SmartSide® panel (cedar texture) or equivalent.
2. Color of exterior paneling shall be light gray.
3. Siding shall be approved for Wind Zone 1 requirements.
4. The manufacturer shall provide a transponder sled. See Appendix A.
5. The sled shall be painted with a powder coat paint to match the exterior color of the MHU or white.
6. The transponder sled shall be made out of sheet metal.
7. Soffit, trim and J-Blocks shall be light gray or white.
8. All penetrations (i.e. electrical wires, HVAC lines, etc.) of the 19/32-inch LP SmartSide paneling or equivalent shall be caulked with a fire caulk. REV 11-15-23 . Feb 03, 2025
26'-65 8"
48 48
4'-0"8'-0"50'-8"
50'-8"
48 4848 48
20'-0" 16'-0" 12'-0"
42'-8" 46'-8"
- SPRING HANGER
- SISTER BEAM
1 4
1 4
1 2
- S
ID
E A
Drawing Notes
FRAME CLIP DETAIL
(SAME ON BOTH MAIN I-BEAMS)
**DIMS ARE PULLED FROM END OF HEADER BEAM.
**BE SURE TO VERIFY FLOOR JOIST LAYOUT TO MATCH CLIPS TO JOISTS.
50'-8"
FRAME CLIPS IN AXLE AREA ARE LOCATED ON INSIDE OF SISTER BEAM AS SHOWN.
1'-4" 2'-8"
5'-4" 6'-8"
9'-7" (MOVED JOIST)
10'-8"
13'-4"
14'-5" (MOVED JOIST)
21'-4"25'-51 2"28'-0"
29'-4" 22'-8" 30'-8"
33'-4"
34'-8"
40'-0"
LONGITUDINAL
BRACKET
LONGITUDINAL
BRACKET
FRONT AND REAR HEADER SHEARWALL LAG BOLT SPACING
A-FRAME
RE-INFORCEMENT
CENTERED AND
UNDER FRONT
HEADER
DETAIL "C", SEE CHASSIS DETAILS
SEE CHASSIS DETAILS, DETAIL "A"
3'-6"
12" X 10.8# I-BEAM HEADER
12" X 10.8# I-BEAM HEADER
LONGITUDINAL BRACKETS
LOCATED PER NOTE 12
24'-0"
32'-0"
36'-0" 37'-4"
38'-8"
41'-21 2"44'-0"
45'-4" 48'-0"
49'-4"
17'-51
2" CENTER OF AXLES 33'-21
2" CENTER OF AXLES (65.5% OF FRAME LENGTH)
26'-8"
17'-51 4"
17'-23 4"
3217 1732 32 32
25'-4"
START
SISTER
BEAMMIN. 16'-0" LENGTH OF SISTER BEAM (TYP.)
DETAIL "B"
29'-05 8"
25'-4"
16'-01
2" INSTALL TIRE BLOW-OUT
PROTECTION IN THIS AREA (BOTH SIDES)
31'-97 8"34'-71
8"37'-43 8"
25'-31
2" START SISTER BEAM AND BLOW-OUT PROTECTION
16475
41'-4"
19'-01 4"
18'-93 4"
OUTRIGGER LOCATION DIMENSIONS
ARE TO THE CENTERLINE OF THE
TOP FLANGE HOLE (TYP).
OUTRIGGER LOCATION DIMENSIONS
LONGITUDINAL BRACKETS
LOCATED PER NOTE 12.
TITLE:
Scale: 1/8" = 1'-0"
Date: 03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency D-14B2-11.1
DRAWING NO.
CHASSIS
Chassis Frame Notes
1. All metal-to-metal contact with 1/8” fillet weld minimum.
2. Floor shall be lagged to frame with frame clip, Fastec 9mm x 76mm listed lags or lags equivalent in size and strength at each joist and outrigger tip.
Alternate lags must be reviewed and approved by FEMA or their designee.
3. Clips shall be welded to the I-beam.
4. All parts of the chassis including added/welded parts shall be completely coated with waterproof paint.
5. Tires shall be new, 14.5” rim diameter, 14 ply with “G” load range.
6. Wheels and tires shall meet or exceed the axle rating and be rated for continuous speeds of 65 mph or greater.
7. All axles shall be new.
8. All axles shall be brake axles.
9. A valve stem cover shall be present on every tire.
10. The serial number shall be permanently stamped to the front header to comply with 3280.6. In addition, the serial number shall be painted with rust resistance contrasting color paint, 2 inches (2”) tall on the front header.
11. Rims, bolts, nuts, or other related tire-mounting hardware shall be new.
12. Longitudinal brackets shall be installed at 8'-0” maximum from each end of the home.
13. Springs shall be 24 3/4" long multi-leaf.
14. All rims shall be the same color.
15. Maximum typical pier spacing along main I-beams @ 8'-0” o.c. Typical pier load = 6,400 lbs.
16. Manufacturer to place permanent indicators (paint or label) on each I-Beam @ 2'-0" from each end, 12'-0" on center max, and at door jambs for location temporary piers for storage.
17. Longitudinal bracket slot to face towards closest end of home.
18. Structural steel shall be A36 AND Fy: 36Ksi.
19. Longitudinal brackets located in the axle area must be located on the inside I-beam of the double I-beam.
14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
Frame Specs
· Main I-Beam: 12" x 10.8# or equivalent with transportation test.
· Front and Rear Headers: 12" x 10.8# or equivalent with transportation test.
· Crossmember: 13 Ga. C or Z, 1-1/2" x 3" x 1-1/2"x13 Ga.
· Outriggers: 9" Min Depth at I-Beam tapered to 1" , 13 Ga min., C or Z type, with 1-1/2" flange top and bottom.
· Frame Clips: 1" x 1-1/2" x 12 Ga.
Hitch Specs
· See Chassis Details, Details "A"
Welding Specs
1. All welds to be a minimum 1/8" unless otherwise noted. Weld beads can be concave in application as long as the weld size is met.
2. Coupler and Jack shall be welded per manufacturer's installation instructions.
3. I-Beam splice plate shall be 4" wide x height of I-Beam minus 1-1/4" x 13 GA.
Splice plate can be offset +/- 1/4". Weld shall be full width of splice plate.
Splice plate only required on one side of I-Beam.
4. Sister I-Beam shall be welded with 1/8" butt welds 2" long at 24" o.c. top and bottom of I-beam
5. All weld lengths stated or shown are minimum lengths and shall have a tolerance of minus 1/4" (except spring hangers). Weld lengths that are not noted shall be full length.
REV 02-03-25
26'-65 8"
48 48
4'-0"8'-0"50'-8"
50'-8"
48 4848 48
20'-0" 16'-0" 12'-0"
42'-8"46'-8"
- SPRING HANGER
- SISTER BEAM
1 4
1 4
1 2
- S
ID
E A
Drawing Notes
FRAME CLIP DETAIL
(SAME ON BOTH MAIN I-BEAMS)
**DIMS ARE PULLED FROM END OF HEADER BEAM.
**BE SURE TO VERIFY FLOOR JOIST LAYOUT TO MATCH CLIPS TO JOISTS.
50'-8"
FRAME CLIPS IN AXLE AREA ARE LOCATED ON INSIDE OF SISTER BEAM AS SHOWN.
1'-4" 2'-8"
5'-4" 6'-8"
9'-7" (MOVED JOIST)
10'-8"
13'-4"
14'-5" (MOVED JOIST)
21'-4"25'-51 2"28'-0"
29'-4" 22'-8" 30'-8"
33'-4"
34'-8"
40'-0"
LONGITUDINAL
BRACKET
LONGITUDINAL
BRACKET
FRONT AND REAR HEADER SHEARWALL LAG BOLT SPACING
A-FRAME
RE-INFORCEMENT
CENTERED AND
UNDER FRONT
HEADER
DETAIL "C", SEE CHASSIS DETAILS
SEE CHASSIS DETAILS, DETAIL "A"
3'-6"
12" X 10.8# I-BEAM HEADER
12" X 10.8# I-BEAM HEADER
LONGITUDINAL BRACKETS
LOCATED PER NOTE 12.
24'-0"
32'-0"
36'-0" 37'-4"
38'-8"
41'-21 2"44'-0"
45'-4" 48'-0"
49'-4"
17'-51
2" CENTER OF AXLES 33'-21
2" CENTER OF AXLES (65.5% OF FRAME LENGTH)
26'-8"
17'-51 4"
17'-23 4"
3217 1732 32 32
25'-4"
START
SISTER
BEAMMIN. 16'-0" LENGTH OF SISTER BEAM (TYP.)
DETAIL "B"
29'-05 8"
25'-4"
16'-1" INSTALL TIRE BLOW-OUT
PROTECTION IN THIS AREA (BOTH SIDES)
31'-97 8"34'-71
8"37'-43 8"
25'-31
2" START SISTER BEAM AND BLOW-OUT PROTECTION
16475
41'-4"
19'-01 4"
18'-93 4"
OUTRIGGER LOCATION DIMENSIONS
ARE TO THE CENTERLINE OF THE
TOP FLANGE HOLE (TYP).
LONGITUDINAL BRACKETS
LOCATED PER NOTE 12.
TITLE:
Scale: 1/8" = 1'-0"
Date: 4/30/2021FEMA Manufactured Housing Units Federal Emergency Management Agency D-14B2-11.1.1
DRAWING NO.
Chassis Frame Notes
1. All metal-to-metal contact with 1/8” fillet weld minimum.
2. Floor shall be lagged to frame with frame clip, Fastec 9mm x 76mm listed lags or lags equivalent in size and strength at each joist and outrigger tip.
Alternate lags must be reviewed and approved by FEMA or their designee.
3. Clips shall be welded to the I-beam.
4. All parts of the chassis including added/welded parts shall be completely coated with waterproof paint.
5. Tires shall be new, 14.5” rim diameter, 14 ply with “G” load range.
6. Wheels and tires shall meet or exceed the axle rating and be rated for continuous speeds of 65 mph or greater.
7. All axles shall be new.
8. All axles shall be brake axles.
9. A valve stem cover shall be present on every tire.
10. The serial number shall be permanently stamped to the front header to comply with 3280.6. In addition, the serial number shall be painted with rust resistance contrasting color paint, 2 inches (2”) tall on the front header.
11. Rims, bolts, nuts, or other related tire-mounting hardware shall be new.
12. Longitudinal brackets shall be installed at 8'-0” maximum from each end of the home.
13. Springs shall be 24 3/4" long multi-leaf.
14. All rims shall be the same color.
15. Maximum typical pier spacing along main I-beams @ 8'-0” o.c. Typical pier load = 6,400 lbs.
16. Manufacturer to place permanent indicators (paint or label) on each I-Beam @ 2'-0" from each end, 12'-0" on center max, and at door jambs for location temporary piers for storage.
17. Longitudinal bracket slot to face towards closest end of home.
18. Structural steel shall be A36 AND Fy: 36Ksi.
19. Longitudinal brackets located in the axle area must be located on the inside I-beam of the double I-beam.
14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX DALT. CHASSIS
(95.5" I-BEAM SPACING)
Frame Specs
· Main I-Beam: 12" x 10.8# or equivalent with transportation test.
· Front and Rear Headers: 12" x 10.8# or equivalent with transportation test.
· Crossmember: 13 Ga. C or Z, 1-1/2" x 3" x 1-1/2"x13 Ga.
· Outriggers: 9" Min Depth at I-Beam tapered to 1" , 13 Ga min., C or Z type, with 1-1/2" flange top and bottom.
· Frame Clips: 1" x 1-1/2" x 12 Ga.
Hitch Specs
· See Chassis Details, Details "A"
Welding Specs
1. All welds to be a minimum 1/8" unless otherwise noted. Weld beads can be concave in application as long as the weld size is met.
2. Coupler and Jack shall be welded per manufacturer's installation instructions.
3. I-Beam splice plate shall be 4" wide x height of I-Beam minus 1-1/4" x 13 GA.
Splice plate can be offset +/- 1/4". Weld shall be full width of splice plate.
Splice plate only required on one side of I-Beam.
4. Sister I-Beam shall be welded with 1/8" butt welds 2" long at 24" o.c. top and bottom of I-beam
5. All weld lengths stated or shown are minimum lengths and shall have a tolerance of minus 1/4" (except spring hangers). Weld lengths that are not noted shall be full length.
REV 02-03-25
48 48 42
/4 x x
-3 /4
BA
C
KE
R U
P
/4
E1
/1
1/
BEDROOM #1
VERTICAL WALL BOARD PANEL BREAKS
H O
R
IZ
O N
TA
L
PA
N
EL
S
IZ
E
(IF
A
PP
LI
C
AB
LE
H O
R
IZ
O N
TA
L
PA
N
EL
S
IZ
E
(IF
A
PP
LI
C
AB
LE
3 8
STRESS CUTS IN THE BACK OF GYPSUM
x x
-3
/4
BA
C
KE
R
D O
W N x x
-3
/4
BA
C
KE
R
D O
W N
SEE NOTE 12.
3" x 5" x 20 Ga. Metal Connector Plate, one each side
Min 2 x by top plate width by 10” splice block centered over splice, plus or minus 1 inch. Fastened with (6) - 7/16” x 15 Ga staples or (4) .131" nails each side of splice. Fasteners to have min. 1 inch penetration.
Min 1 x by bottom plate width by 10” splice block centered over splice, plus or minus 1 inch.
Fastened with (6) - 7/16” x 15 Ga staples or (4) .131" nails each side of splice. Fasteners to have min. 1/2 inch penetration.3" x 5" x 20 Ga. Metal Connector
Plate, one each side
TOP PLATE SPLICE
BOTTOM PLATE SPLICE
FASTENING SCHEDULE - EXTERIOR WALLS
STUD TO PLATE
FASTENER APPLICATION
15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL
3 EACH
2 EACH
BOTTOM PLATE TO FLOOR
TOP PLATE TO TRUSS
SILL MEMBER (@ OPENING) TO STUD
MULTIPLE STUDS (TO EACH OTHER)
MULTIPLE FLAT HEADER MEMBERS - (2)
ROWS OF FASTENERS 80% GLUE COVERAGE
CRIPPLES TO HEADER, SILL AND PLATES
GYPSUM TO STUDS , 80% PVA GLUE
ALTERNATE GYPSUM TO STUDS
100% ONE PART URETHANE GLUE
EXTERIOR SIDING SEE SHEARWALL & EXTERIOR SHEATHING DRAWING
LAYFLATS TO TOP/BOTTOM PLATE
DESCRIPTION
0.131" X 3" NAIL
or #8 x 3" WOOD SCREW
12" O.C.
12" O.C.
0.131" X 3" NAIL
or #8 x 4" WOOD SCREW
1 EACH
1 EACH
15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL
9 EACH PLY
6 EACH PLYHEADER TO STUD
15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL 15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL 15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL 15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL
3 EACH
2 EACH
12" O.C.
12" O.C.
6" O.C.
6" O.C.
3 EACH
2 EACH
19Ga. x 3/16" x 1-1/4" STAPLES or DRYWALL SCREWS
6" EDGES
6" EDGES
19Ga. x 3/16" x 1-1/4" STAPLES or DRYWALL SCREWS
6" Edges / 12" Field 6" Edges / 12" Field
15 Ga. x 7/16" x 2-1/2" STAPLES 2 EACH
BACKERS TO STUD - BACKERS SHALL
BE #3 SPF MIN. AND SIZE AS SHOWN ON
DRAWINGS.
15Ga. x 7/16" x 2-1/2" STAPLES
(END GRAIN ONLY)
OR .131" X 3" NAIL (END GRAIN OR TOED)
6 EACH
3 EACH
TITLE:
1/4" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-17.1
DRAWING NO.ENDWALL FRAMING
INTERIOR SHEATHING
14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
Wall Framing Notes
1. The exterior wall framing shall be 2 x 6 nominal #2 SPF at 24” o.c.
2. Wall framing shall be 7'-6” from floor to ceiling.
3. Sidewall top plates shall be single 2 x 6 nominal #2 SPF.
4. Sidewall bottom plate shall be single 1 x 6 nominal SPF.
5. All major joints - wall to wall, wall to ceiling, wall to floor shall be caulked or gasketed to prevent air infiltration.
6. The wall insulation shall be kraft backed R-19 and will be installed without voids, gaps, or compression.
7. N/A
8. The walls shall be painted with latex, low VOC paint.
9. Housewrap applied over exterior sheathing.
10. All exterior penetrations (vents, lights, outlets, etc.) shall be flashed with ice and water shield 12” wide around penetration. Refer to Appendix 'A' for window and door flashing details.
11. Wall interiors shall be faced with 1/2" Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.
12. When gypsum is installed horizontally a 1/8" x 3" continuous plywood backer strip shall be installed at the horizontal joint. Fasten to each stud with 2- 7/16 x 15 GA staples (min. 1" penetration). REV 02-03-25
/4
18 15
E2
33 1/2
42 66 90 11
BEDROOM #2
26 1/24842
1/ x x
-3
/4
BA
C
KE
R
U P
H O
R
IZ
O N
TA
L
PA
N
EL
S
IZ
E
(IF
A
PP
LI
C
AB
LE
H O
R
IZ
O N
TA
L
PA
N
EL
S
IZ
E
(IF
A
PP
LI
C
AB
LE
SEE NOTE 12.
TITLE:
1/4" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-17.2
DRAWING NO.ENDWALL FRAMING
INTERIOR SHEATHING
14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
Wall Framing Notes
1. The exterior wall framing shall be 2 x 4 nominal #2 SPF at 24” o.c.
2. Wall framing shall be 7'-6” from floor to ceiling.
3. Sidewall top plates shall be single 2 x 4 nominal #2 SPF.
4. Sidewall bottom plate shall be single 1 x 4 nominal SPF.
5. All major joints - wall to wall, wall to ceiling, wall to floor shall be caulked or gasketed to prevent air infiltration.
6. The wall insulation shall be kraft backed R-13 and will be installed without voids, gaps, or compression.
7. N/A
8. The walls shall be painted with latex, low VOC paint.
9. Housewrap applied over exterior sheathing.
10. All exterior penetrations (vents, lights, outlets, etc.) shall be flashed with ice and water shield 12” wide around penetration. Refer to Appendix 'A' for window and door flashing details.
11. Wall interiors shall be faced with 1/2" Gold Bond XP gypsum board with paint or equvalent installed per ASTM C840 and GA-216.
12. When gypsum is installed horizontally a 1/8" x 3" continuous plywood backer strip shall be installed at the horizontal joint. Fasten to each stud with 2- 7/16 x 15 GA staples (min. 1" penetration). REV 02-03-25
#8x4" SCREWS @
6-1/2" OC THRU BOTTOM
PLATE INTO END
FLOOR JOISTS
1x6 BOTTOM PLATE
#8x4 1/2" MIN. SCREWS
INTO SIDEWALL STUD
@ 12" O.C.
(1)-2x6 TOP PLATE
SHEATHING FASTENED TO TRUSS
PER SHEARWALL SCHEDULE
7/16" OSB ON EXTERIOR SIDE FASTENED
WITH 0.131X2-1/2" NAILS @ 6"
O.C. ON EDGES, 12" O.C. IN FIELD.
#8x4" SCREWS @
6-1/2" OC THRU TRUSS
INTO TOP PLATE
(STAGGER FASTENERS). SEE NOTE 10.
(4) 1 1/2"x12"x26 GA.
STRAPS W/ (6) 15 GA.
STAPLES (1" MIN.
PENETRATION) EACH
END OF STRAP.
STRAP DETAIL
12" x 10.8# HEADER
(2)-2x8 #2 SPF
SHEARWALL JOISTS
(4) 1 1/2"x12"x26 GA. STRAPS
W/ (6) 15 GA. STAPLES (1"
MIN. PENETRATION) EACH
END OF STRAP.
DOUBLE HEADER AND SILL PLATES
FOR PANEL EDGE FASTENING.
END TRUSSES ONLY - ADD VERTICALS TO
MAINTAIN 24" O.C. SPACING. ADDED VERTICALS
SHALL BE 2X4 #2 SPF. FASTEN WITH (2) - .131" X
3" NAILS TOED EACH CONNECTION.
2x6 #2 SPF BACKERS
FOR PACKAGE SYSTEM
LAGGING
(4) 1 1/2"x12"x26 GA. STRAPS
W/ (6) 15 GA. STAPLES (1"
MIN. PENETRATION)
EACH END OF STRAP.
SI
D
EW
AL
L
SI
D
EW
AL
L
2 - I-BEAM SPACING
E1FRONT SHEARWALL
2 X 6 BACKERS
81 8 SUPPLY
OPENING33 4
3 8 x x
-3
/4
BA
C
KE
R
D O
W N x x
-3
/4
BA
C
KE
R
D O
W N
TITLE:
1/4" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-18.1
DRAWING NO.FRONT SHEARWALL FRAMING
AND
EXTERIOR SHEATHING
14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
Shearwall Notes
1. Shearwall joists shall be (2)-2x8 #2 SPF.
2. Shearwall shall be lagged to 12" x 10.8# I-Beam header with five (5) equally spaced, Fastec 9mm x 76mm listed lags or equivalent.
3. 7/16" (24/16 span index) OSB shearwall sheathing shall be continuous over the shearwall joist and fastened with 1 row of .131 x
3" nails @ 6" o.c.
4. OSB shearwall sheathing shall be fastened to studs with .131 x 3" nails @ 6" o.c. at edges and 12" o.c. in field.
5. OSB shearwall sheathing shall be continuous over the truss bottom chord and fastened with 1 row of .131 x 3" nails at 6" o.c.
6. Package System backer locations will vary per package system vendor.
7. Backers shall be #3 SPF min. and size as shown on drawings.
8. Shearwall OSB sheathing to be overlaid with 19/32” thick LP SmartSide® panel or equivalent.
9. 19/32” thick LP SmartSide® panel or equivalent shall be fastened with 0.113 diameter galvanized nails with a minimum 0.270-inch diameter head, minimum 1 ½ inch penetration into framing members. Fasteners to be spaced 3 inches o.c. at panel edges and 8 inches o.c. at intermediate framing members. Nominal 1/4" bead of UL listed fire rated caulk required at all vertical joints.
10. Truss to truss bottom chord fastening NOT required for double trusses over end shearwalls. Truss bottom chord fastening to top plate to be staggered from one truss bottom chord to the other truss bottom chord.
11. N/A
12. See Appendix A, Detail F.2 for clarification of shearwall OSB sheathing joint and fastening. REV 9-8-22
SI
D
EW
AL
L
SI
D
EW
AL
L
E2
2 - I-BEAM SPACING
12" x 10.8# HEADER
(2)-2x8 #2 SPF
SHEARWALL JOISTS
#8x4" SCREWS @ 8 1/4" OC THRU BOTTOM
PLATE INTO END FLOOR JOISTS
1x6 BOTTOM PLATE
#8x4" SCREWS INTO SIDEWALL
STUD @ 12" OC
(1)-2x6 TOP PLATE
SHEATHING FASTENED TO TRUSS
PER SHEARWALL SCHEDULE
7/16" OSB ON EXTERIOR SIDE FASTENED
WITH 0.131X2-1/2" NAILS @ 6" OC ON
EDGES, 12" OC IN FIELD
REAR SHEARWALL
#8x4" SCREWS @ 8 1/4" OC THRU
TRUSS INTO TOP PLATE
(STAGGER FASTENERS). SEE NOTE 10.
END TRUSSES ONLY - ADD VERTICALS TO
MAINTAIN 24" O.C. SPACING. ADDED VERTICALS
SHALL BE 2X4 #2 SPF. FASTEN WITH (2) - .131" X
3" NAILS TOED EACH CONNECTION.
(3) 1 1/2"x12"x26 GA. STRAPS
W/ (6) 15 GA. STAPLES (1"
MIN. PENETRATION) EACH
END OF STRAP.
(3) 1 1/2"x12"x26 GA. STRAPS
W/ (6) 15 GA. STAPLES (1"
MIN. PENETRATION)
EACH END OF STRAP.
(3) 1 1/2"x12"x26 GA.
STRAPS W/ (6) 15 GA.
STAPLES (1" MIN.
PENETRATION) EACH
END OF STRAP.
STRAP DETAIL
TITLE:
1/4" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-18.2
DRAWING NO.REAR SHEARWALL FRAMING
AND
EXTERIOR SHEATHING
14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
Shearwall Notes
1. Shearwall joists shall be (2)-2x8 #2 SPF.
2. Shearwall shall be lagged to 12" x 10.8# I-Beam header with five (5) equally spaced, Fastec 9mm x 76mm listed lags or equivalent.
3. 7/16" (24/16 span index) OSB shearwall sheathing shall be continuous over the shearwall joist and fastened with 1 row of .131 x 3" nails @ 6" o.c.
4. OSB shearwall sheathing shall be fastened to studs with .131 x 3" nails @ 6" o.c. at edges and 12" o.c. in field.
5. OSB shearwall sheathing shall be continuous over the truss bottom chord and fastened with 1 row of .131 x 3" nails at 6" o.c.
6. Package System backer locations will vary per package system vendor.
7. Backers shall be #3 SPF min. and size as shown on drawings.
8. Shearwall OSB sheathing to be overlaid with 19/32” thick LP SmartSide® panel or equivalent.
9. 19/32” thick LP SmartSide® panel or equivalent shall be fastened with 0.113 diameter galvanized nails with a minimum 0.270-inch diameter head, minimum 1 ½ inch penetration into framing members. Fasteners to be spaced 3 inches o.c. at panel edges and 8 inches o.c. at intermediate framing members. Nominal 1/4" bead of UL listed fire rated caulk required at all vertical joints.
10. Truss to truss bottom chord fastening NOT required for double trusses over end shearwalls. Truss bottom chord fastening to top plate to be staggered from one truss bottom chord to the other truss bottom chord.
11. N/A
12. See Appendix A, Detail F.2 for clarification of shearwall OSB sheathing joint and fastening. REV 9-8-22
0"
/4
2' -0
'-8
4' -0
/4
6' -0
6' -7
/4
8' -0
'-0
'-0
30 1/2
WINDOW
BA
C
KE
R
U P 37 1/4
/4
30 1/2
/2
'-0
'-0
'-1
0"
'-8
/4
'-0
'-4
'-0
'-0
'-0
'-0
'-0
'-0
'-4
/4
'-1
3/
4"
'-4
/4
'-0
'-0
'-0
'-0
EXT. DOOR WINDOW
16 3/4 48 37 1/4 DOOR HDR 26
30 1/2
WINDOW 42 48
/4 C
LO
S
H
EL
F
30 1/2
/2
PA
N
EL
B
O X
'-0
'-0
'-0
BCKR
UP
2X6 BA
C
KE
R
U P
BA
C
KE
R
U P
WINDOW
48 32 3/4 48 48 28 1/4 43 1/4
O H
EA
D
C
AB
IN
ET
S
O
H
EA
D C
AB
IN
ET
S
O
H
EA
D C
AB
IN
ET
S
O
H
EA
D C
AB
IN
ET
S
P
AN
TR
Y72 P
AN
TR
Y
K
.S
IN
K
1/
/4
1/
/4
S1
H
IT
C H
E N
D
30 1/2 145 1/2 37 1/4 50 124 1/4 30 1/2 141 1/4
1/
/2
/2
H O
R
IZ
O N
TA
L
PA
N
EL
S
IZ
E
(IF
A
PP
LI
C
AB
LE
H O
R
IZ
O N
TA
L
PA
N
EL
S
IZ
E
(IF
A
PP
LI
C
AB
LE
HORIZONTAL
WALLBOARD
LAYOUT
VERTICAL
WALLBOARD
LAYOUT
PA
N
EL
B
O X
BCKR
UP
2X6
C
LO
S
H
EL
F
'-0
VERTICAL WALL BOARD PANEL BREAKS
SEE NOTE 12.
SEE NOTE 12.
1 1/2"x12"x26 Ga STRAP W/ (6) - 15Ga STAPLES
(MIN. 1" PENETRATION) EACH END OF STRAP.
ONE STRAP AT FIRST STUD.
1 1/2"x12"x26 Ga STRAPS W/ (6) - 15Ga STAPLES
(MIN. 1" PENETRATION) EACH END OF STRAP.
ONE STRAP AT FIRST STUD.
1 1/2"x12"x26 Ga STRAPS W/ (6) - 15Ga STAPLES
(MIN. 1" PENETRATION) EACH END OF STRAP.
ONE STRAP AT FIRST STUD.
1 1/2"x12"x26 Ga STRAPS W/ (7) - 15Ga
STAPLES (MIN. 1" PENETRATION) EACH
END OF STRAP. (SEE NOTE 12 ALSO)
1 1/2"x12"x26 Ga STRAPS W/ (7) - 15Ga
STAPLES (MIN. 1" PENETRATION) EACH
END OF STRAP. (SEE NOTE 12 ALSO)
1 1/2"x12"x26 Ga STRAP W/ (6) - 15Ga STAPLES
(MIN. 1" PENETRATION) EACH END OF STRAP.
ONE STRAP AT FIRST STUD.
BACKER
UP
2X6
(ALL)
BACKER
UP
2X6
(ALL)
24 8
3060-E-SG 3027
PANTRY
P.BOX
36'-41 4"18'-83
4"
SEE NOTE 22.
'-0
3/
29 1/2
29 1/2 19 1/4
19 1/4
2' -5
/2
'-1
/4
" M O
VE
S
TU
D
'-3
/4
" A D
D S
TU
D
30'-7 3/4" RANGE CENTER LINE
R
AN
G
E
VE
N T
210 1/2
7/
RANGE HOOD VENT
TITLE:
1/8" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-19
DRAWING NO.
FRONT DOOR SIDEWALL 14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
Wall Framing Notes
1. The exterior wall framing shall be 2 x 6 nominal #2 SPF at 24” o.c.
2. Wall framing shall be 7'-6” from floor to ceiling.
3. Sidewall top plates shall be single 2 x 6 nominal #2 SPF.
4. Sidewall bottom plate shall be single 1 x 6 nominal SPF.
5. All major joints - wall to wall, wall to ceiling, wall to floor shall be caulked or gasketed to prevent air infiltration.
6. The wall insulation shall be kraft backed R-19 and will be installed without voids, gaps, or compression.
7. Siding shall be 19/32” thick LP SmartSide® panel (cedar texture) or equivalent.
8. The walls shall be painted with latex, low VOC paint.
9. Headers shall be (2) 2 x 6 #2 SPF flat or equal fastened together with 80% adhesive and 7/16 x 2 ½ x 15 GA staples or .131 x 3” pd nails, 2 rows @ 6” o.c.
10. Housewrap applied over exterior sheathing.
11. All exterior penetrations (vents, lights, outlets, etc.) shall be flashed with ice and water shield 12” wide around penetration. Refer to Appendix 'A' for window and door flashing details.
12. Fasten stud to floor edge rail and roof edge rail with (1) 1 ½” x 12” x 26 ga strap with (6) 15 ga. staples (1" min. penetration) each end of strap. Straps spaced at 48" o.c.
13. N/A
14. Grab bar backers to be centered at grab bar mounting height.
15. Toilet paper holder backer to be centered at toilet paper holder mounting height.
16. Range hood vent through wall size and location may vary. Manufacturer to verify size and location from range hood vendor that will be used. Range hood vent screen shall have minimum of 1/16 inch, but not to exceed
1/8-inch openings, and shall comply with R337.6 of the 2019 California Residential Code.
17. Gypsum to be jointed above all doors in line with jambs.
18. Gypsum to be jointed above and below all windows in line with jambs.
19. Wall interiors shall be faced with 1/2" Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.
20. 19/32” thick LP SmartSide® panel or equivalent shall be fastened with 0.113 diameter galvanized nails with a minimum 0.270-inch diameter head, minimum 1 ½ inch penetration into framing members. Fasteners to be spaced 3 inches o.c. at panel edges and 8 inches o.c. at intermediate framing members. Nominal 1/4" bead of UL listed fire rated caulk required at all vertical joints.
21. Backers shall be #3 SPF min. and size as shown on drawings.
22. When gypsum is installed horizontally a 1/8" x 3" continuous utility grade plywood backer strip shall be installed at the horizontal joint. Fasten to each stud with 2- 7/16 x 15 GA staples (min. 1" penetration).
REV 02-03-25
306030603060-E S2
0"
/4
2' -0
'-8
S2
4' -0
6' -0
8' -0
'-0
'-0
48 48 x x
-3
/4
BA
C
KE
R
U P
37 1/4
/4
30 1/2
/2
30 1/2
/2
30 1/2
/2
37 1/4
/4 x x
-3
/4
BA
C
KE
R
U P x x
-3
/4
BA
C
KE
R
U P
'-0
'-0
'-7
/2
'-0
'-0
'-0
'-8
/4
'-0
'-3
/4
'-0
'-4
/4
'-1
1/
4"
'-0
'-0
/2
'-9
/4
'-0
'-3
/4
'-0
'-0
EXT. DOORWINDOWWINDOWEXT. DOORWINDOW
BCKR
UP
2X6
/4 C
LO
. S
H
EL
F
484818 1/437 1/4 DOOR HDR40 1/232 3/425 1/2
30 1/2
WINDOW
30 1/2
WINDOW37 1/4 DOOR HDR 37 1/4
30 1/2
WINDOW 43 1/252 1/4
BACKER
UP
2X6
BACKER
UP
2X6
BACKER
UP
2X6
BACKER
UP
2X6
BACKER
UP
2X6
BACKER
UP
2X6
BACKER
UP
2X6
T
.P
/2 G
R
AB
B
AR
T
O W
EL
B
AR
x x
-3
/4
BA
C
KE
R
U P
1/
/4
1/
/4
1/
/4
3/
H
IT
C H
E N
D
94 3/4115 1/237 1/473 1/437 1/437 1/430 1/2 43 1/252 1/4
HORIZONTAL
WALLBOARD
LAYOUT
VERTICAL
WALLBOARD
LAYOUT
/2 10 9 1/
/2
/2 10 9 1/
H O
R
IZ
O N
TA
L
PA
N
EL
S
IZ
E
(IF
A
PP
LI
C
AB
LE
H O
R
IZ
O N
TA
L
PA
N
EL
S
IZ
E
(IF
A
PP
LI
C
AB
LE
25 1/230 1/2 30 1/2
'-1
/4
'-0
BCKR
UP
2X6
C
LO
. S
H
EL
F
'-0
'-6
/4
BCKR
UP
2X6
SEE NOTE 12.
SEE NOTE 12.
1 1/2"x12"x26 Ga STRAP W/ (6) - 15Ga STAPLES
(MIN. 1" PENETRATION) EACH END OF STRAP.
ONE STRAP AT FIRST STUD.
1 1/2"x12"x26 Ga STRAPS W/ (6) - 15Ga STAPLES
(MIN. 1" PENETRATION) EACH END OF STRAP.
ONE STRAP AT FIRST STUD.
1 1/2"x12"x26 Ga STRAPS W/ (6) - 15Ga STAPLES
(MIN. 1" PENETRATION) EACH END OF STRAP.
ONE STRAP AT FIRST STUD.
1 1/2"x12"x26 Ga STRAPS W/ (7) - 15Ga
STAPLES (MIN. 1" PENETRATION) EACH
END OF STRAP. (SEE NOTE 12 ALSO)
1 1/2"x12"x26 Ga STRAPS W/ (7) - 15Ga
STAPLES (MIN. 1" PENETRATION) EACH
END OF STRAP. (SEE NOTE 12 ALSO)
1 1/2"x12"x26 Ga STRAP W/ (6) - 15Ga STAPLES
(MIN. 1" PENETRATION) EACH END OF STRAP.
ONE STRAP AT FIRST STUD.
'-0
25'-0" (2x6) SPRINKLER BLOCK 35'-0 3/4" (2x6) SPRINKLER BLOCK
BACKER
UP
2X6
BACKER
UP
2X6
19'-0" (2x4) SPRINKLER BLOCK
BACKER
UP
2X4
SEE NOTE 22.
'-0
'-0
'-0
3/
'-5 x x
-3 /4
BA
C
KE
R U
P
TITLE:
1/8" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-20
DRAWING NO.
BACK DOOR SIDEWALL 14' WIDE MHU
(PACKAGED SYSTEM)
APPENDIX D
Wall Framing Notes
1. The exterior wall framing shall be 2 x 6 nominal #2 SPF at 24” o.c.
2. Wall framing shall be 7'-6” from floor to ceiling.
3. Sidewall top plates shall be single 2 x 6 nominal #2 SPF.
4. Sidewall bottom plate shall be single 1 x 6 nominal SPF.
5. All major joints - wall to wall, wall to ceiling, wall to floor shall be caulked or gasketed to prevent air infiltration.
6. The wall insulation shall be kraft backed R-19 and will be installed without voids, gaps, or compression.
7. Siding shall be 19/32” thick LP SmartSide® panel (cedar texture) or equivalent.
8. The walls shall be painted with latex, low VOC paint.
9. Headers shall be (2) 2 x 6 #2 SPF flat or equal fastened together with 80% adhesive and 7/16 x 2 ½ x 15 GA staples or .131 x 3” pd nails, 2 rows @ 6” o.c.
10. Housewrap applied over exterior sheathing.
11. All exterior penetrations (vents, lights, outlets, etc.) shall be flashed with ice and water shield 12” wide around penetration. Refer to Appendix 'A' for window and door flashing details.
12. Fasten stud to floor edge rail and roof edge rail with (1) 1 ½” x 12” x 26 ga strap with (6) 15 ga. staples (1" min. penetration) each end of strap. Straps spaced at 48" o.c.
13. N/A
14. Grab bar backers to be centered at grab bar mounting height.
15. Toilet paper holder backer to be centered at toilet paper holder mounting height.
16. Gypsum to be jointed above all doors in line with jambs.
17. Gypsum to be jointed above and below all windows in line with jambs.
18. Sprinkler head backer location may vary based on sprinkler design.
19. Wall interiors shall be faced with 1/2" Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.
20. 19/32” thick LP SmartSide® panel or equivalent shall be fastened with 0.113 diameter galvanized nails with a minimum 0.270-inch diameter head, minimum 1 ½ inch penetration into framing members. Fasteners to be spaced 3 inches o.c. at panel edges and 8 inches o.c. at intermediate framing members. Nominal 1/4" bead of UL listed fire rated caulk required at all vertical joints.
21. Backers shall be #3 SPF min. and size as shown on drawings.
22. When gypsum is installed horizontally a 1/8" x 3" continuous utility grade plywood backer strip shall be installed at the horizontal joint. Fasten to each stud with 2- 7/16 x 15 GA staples (min. 1" penetration).
REV 02-03-25
21'-11 4"
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
" 0"
'-0
'-0
'-0
'-0
'-0
'-0
'-0
2' -0
" 0"
SC
SC
'-0
8' -0
6' -0
4' -0
'-0
1 2
1 2
16'-21 4"
7'-91 2"
2'-51 2"
DRAWING NOTES:
· START WITH A 32" CUT PIECE OF CEILING BOARD
· 1x4 OR PLANT STANDARD CEILING BACKERS FOR
WALL TIE-IN.
· ALL DUCTS TO BE MINIMUM R-4.
45'-8"
46'-4" 35'-01 2"
27'-7"
14'-4"
4'-5"
4'-5"
62 58
60 62
PANEL BOX
'-8
42'-43 4"
2'-6" 11'-7"25'-6"37'-0"
33'-6" 46'-6"
1 2
1 2
1 2
1 2
1 2
1 2
CEILING BOARD LAYOUT
32 48 48 48 48 48 48 48 48 48 48 48 48
CEILING BOARD LAYOUT
2x4x12" #2 SPF BLOCKS AT 2'-0" O.C. 2x4x12" #2 SPF BLOCKS AT 2'-0" O.C.
1 2
17'-6"
35'-5"
48'-21 4"
18'-73 4"
1 2
42'-9" (2x6x96")
20'-83 4"(2x6x48")
7'-5" (2x6x120")
8'-31
2" VTR
14'-4"
SC
29'-8"
FACIA SPLICE EDGE RAIL SPLICE
3" X 4" X 20 GA.
Metal connector plate, one each side
Min 2" X 4" X 14" block centered over splice +/- 1/4" and fastened with 80% coverage PVA adhesive and 4-.131x3" nails each side of splice
3" X 4" X 20 GA.
Metal connector plate, one each side
Min 2" X 6" X 14" block centered over splice +/- 1" and fastened with 80% coverage PVA adhesive and 6-.131x3" nails each side of splice
2x6 edge rail2x4 Fascia 2x4 Fascia 2x6 edge rail
TITLE:
1/8" = 1'-0"
03/25/2020FEMA Manufactured Housing Units Federal Emergency Management Agency
DATE:
SCALE:
COMPANY: VERSION:
D-14B2-21
DRAWING NO.
ROOF FRAMING LAYOUT
Top plate to truss.
Sheathing to trusses (for optional blocked diaphragm see Note 17.)
OR #8 x 4" screw
0.131 x 2" nail
1 each 1 each 6" o.c. edges
12" o.c. field into each truss unblocked diaphragm
DESCRIPTION FASTENER APPLICATION
FASTENING SCHEDULE - ROOF
0.131 x 3" Nail
Blocking to truss 2 each at each end.7/16"C x 2-1/2"L x 15Ga staple
Gypsum ceiling to truss Foam adhesive (as per installation instructions.)
Layflat to Gypsum ceiling - Lay flats shall be #3 SPF min. and size as shown on drawings.
Tack in place with foam adhesive.
Fascia to truss (3) each, 7/16"C x 2-1/2"L x 15Ga. staples through fascia
Edge rail to truss (8) 7/16"C x 2-1/2"L x 15Ga. staples or (5) .131 x 3" nails Edge rail to top plate 0.131 x 3-1/2" nails or #10 x 4" screws @ 12" o.c. toed.
Strap to edge rail See sidewall drawings for type and quantity of fasteners
Roof Framing Notes
1. The roof trusses shall be spaced at 24” o.c. maximum.
2. Overall shipping width shall not exceed 14'-0".
3. The roof pitch shall be nominal 3:12.
4. The attic insulation shall be R-38 blown insulation.
5. The roof sheathing shall be at least 7/16” structurally rated OSB with 24/16 index minimum span rating.
6. Roof felt shall be 2 layers of 15# felt or 1 layer of 30# felt or equivalent synthetic underlayment.
7. The roof covering shall be cemented to the roof decking with 6” wide strip cement, around the perimeter.
8. Ice and water shield, per ASTM D1970 to be self-adhering rubberized asphalt 40 mils minimum thick shall be installed (36” width from eaves).
9. The roof shall have a light or white colored composition 240# architectural style shingle.
10. Ridge vent shall be Class A rated. Vent opening in ridge vent shall have a minimum of 1/16 inch, but not to exceed
1/8 inch openings, or equivalent and comply with R337.6 of the 2019 California…