A06_Dwgs_01_ORCA_100CD_FINAL_4_FIRE_SUPPRESSION.pdf

PDF 6 MB Posted

Attached to
ORCA 150025 - Correct Life Safety and Critical Def
Solicitation number
140P2019R0045
Issued by

About this file

This pre-solicitation notice seeks proposals for a construction contract to correct life safety and critical deficiencies at the Oregon Caves Chateau National Historic Landmark. The National Park Service will issue a solicitation on or around October 21, 2019 seeking a single prime contractor to perform work including fire suppression and detection system installation, egress door replacements, accessibility improvements, and structural repairs. Eligible firms must have the capability to convert first floor guest rooms to full accessibility, improve public area and restroom access, install a three-story elevator, replace water supply and waste vent piping, update steam systems, replace the main electric panel, add plywood shear walls, and install balconies to meet fire code egress requirements. The estimated price range is over $10,000,000 to be completed from April 2020 through September 2021. The NAICS code is 236220 with a size standard of $36.5 million. Maximum practicable opportunities are to be provided to small businesses, veteran-owned small businesses, small disadvantaged businesses, and women-owned small businesses.

Drawings - Fire Suppression

View the file

Other files

File Type Posted
01 27 00-Definition of Contract Line Items_ORCA Amend 4_0004.pdf PDF
140P2019R0045 Amend 4 SOC_0004.pdf PDF
07_ContractPriceSchedule_ORCA150025_Amend 4_0004.xls XLS spreadsheet
Sol_140P2019R0045_Amd_0004.pdf PDF
09 80 00 Fiberboard Wall Ceiling Treatment_ORCA_0003.pdf PDF
Sol_140P2019R0045_Amd_0003.pdf PDF
B03_Wage_Determination_OR20200039 1-3-2020_0003.pdf PDF
140P2019R0045 Amend 3 SOC_0003.pdf PDF
Sol_140P2019R0045_Amd_0001.pdf PDF
Sol_140P2019R0045_Amd_0002.pdf PDF
00 01 10 Table of Contents_ORCA_r1_0002.pdf PDF
140P2019R0045 Amend 1 SOC.updated_0002.pdf PDF
09 80 00 Fiberboard Wall & Ceiling Treatment_0002.pdf PDF
Sign-in sheet_0002.pdf PDF
L8.03 Landscape Details - A1_0002.pdf PDF
A06_Specs_03_XAPPENDIX-C_ORCA_Chateau_Hazardous_Materials_Report.pdf PDF
A06_Specs_03_XAPPENDIX-D_ORCA_Fire_Protection_Basis_of_Design.pdf PDF
A06_Specs_03_XAPPENDIX-B_ORCA_STRUCT_CALCS_201900913_Pages_1_-_164.pdf PDF
A06_Specs_03_XAPPENDIX-A_ORCA_Geotech_Report.pdf PDF
A06_Specs_03_XAPPENDIX-B_ORCA_STRUCT_CALCS_201900913_Pages_165_-_330.pdf PDF
B08_Solit_PSP_Vol_II_SubKPlanForm_REQD.doc DOC document
B08_Solic_Contract_Price_Schedule_ORCA150025_FINAL.xls XLS spreadsheet
A06_Dwgs_01_ORCA_100CD_FINAL_0_TITLE.pdf PDF
A06_Dwgs_01_ORCA_100CD_FINAL_3_ARCHITECTURE.pdf PDF
A06_Dwgs_01_ORCA_100CD_FINAL_6_PLUMBING.pdf PDF
A06_Dwgs_01_ORCA_100CD_FINAL_8_ELECTRICAL.pdf PDF
B08_Solit_PSP_Vol_II_GenRefs.doc DOC document
B08_Solic_140P2019R0045_SF_1442_&_Clauses.pdf PDF
A06_Specs_02_ORCA_100CD_FINAL_SPECS-DIV-01.pdf PDF
B08_Solit_PSP_Vol_I_Exp_REQD.docx DOCX document
B08_Solic_SF24-16d.pdf PDF
A06_Dwgs_01_ORCA_100CD_FINAL_7_MECHANICAL.pdf PDF
A06_Dwgs_01_ORCA_100CD_FINAL_2_STRUCTURAL.pdf PDF
A06_Dwgs_01_ORCA_100CD_FINAL_5_FIRE_DETECTION.pdf PDF
A06_Specs_02_ORCA_100CD_FINAL_SPECS-DIV-15-48.pdf PDF
B03_Wage_Determination_OR20190039_8-30-19.pdf PDF
B08_Solit_PSP_Vol_I_PastPerf_REQD.docx DOCX document
A06_Specs_02_ORCA_100CD_FINAL_SPECS-DIV-02-14.pdf PDF
A06_Dwgs_01_ORCA_100CD_FINAL_1_LANDSCAPE.pdf PDF
B08_Solit_PSP_Cover.rtf RTF text file
B08_Solit_PSP_Vol_II_Equals.doc DOC document
B08_Solit_PSP_Vol_II_HazMat.doc DOC document
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M M

ROOF

SPRINKLER

RELEASE

EXTERIOR

MIST

RELEASE

FIRE SUPPRESSION LEGEND

STANDARD RESPONSE PENDANT

SPRINKLER - VIKING VK102 K-5.6

STANDARD RESPONSE UPRIGHT

SPRINKLER - VIKING VK100 K-5.6

QUICK RESPONSE CONCEALED PENDANT

SPRINKLER - VIKING VK 462

QUICK RESPONSE DRY PENDANT

SPRINKLER - VIKING VK482 K-5.6

HORIZONTAL SIDEWALL SPRINKLER -

VIKING VK104 K-5.6

CONCEALED HORIZONTAL SPRINKLER -

VIKING VK481 K-5.6

QUICK RESPONSE VERTICAL SIDEWALL

SPRINKLER VIKING VK106 K-5.6

WATER MIST NOZZLE - TELESTO MIST

CURTAIN K1/K2

RISER

ATTIC SPRINKLER VIKING V-BB 200 DEG. F

TELESTO ROOF MIST NOZZLE NGW P62

FIRE HOSE CABINET

STEEL SCHEDULE 40 PIPE

CPVC PIPE

COPPER TUBE

16 18

3 5

4 6 8

10 11

17 19

CROSS MAIN BRANCH

PIPE

SPRINKLER

BEAM

FLOOR

SPRINKLER BANCH

NEW CEILING

CONCEALED SPRINKLER

CROSS MAIN THROUGH BEAM

ROOF SPRINKLER

ROOF SPRINKLER BRANCH

ROOF SPRINKLER MAIN (COPPER)ATTIC SPRINKLER AND MAIN (STEEL)

ATTIC SPACE

DRY ZONE MAIN (STEEL)

TYPICAL THRD FLOOR ROOM DRY PENDANT SPRINKLERS

THIRD LEVEL

EXTERIOR MIST MAIN (COPPER)

EXTERIOR MIST NOZZLE

DECK

COPPER MAIN SUPPLY

K1 OR K2 NOZZLE

1"THREAD COPPER

1"COPPER

LOG STRUCTURE

TITLE OF SHEETSUB SHEET NO.DESIGNED:

TECH REVIEW:

DATE:

DRAWING NO.

PMIS/PKG. NO.

SHEET

OF

138578

150025

OREGON CAVES NATIONAL MONUMENT

OREGON CAVES CHATEAU

R E

V

IT

/1

/2

:1

:3

P M

C U s e rs

\s w b ra

\D o c u m e n ts \0

-W o rk

\C lie n ts

\H P

G \P

R O

J E

C T

S \O

R C

A \R e v it \O

R C

A

F

IR

E

S U

P R

E S

S

IO

N .r v t

N.A.

B.S.

N.A.

9/13/2019

FIRE PROTECTION

DETAILS & NOTESFS2.00

134 210

CONSTRUCTION DRAWINGS

F S

.0

B

.S

1. SPRINKLER SYSTEM TO BE BID OPTION D.

2. THE SPRINKLER SYSTEM SHALL BE ARRANGED AS

FOLLOWS:

A. WET ZONE - ALL FLOOR AREAS ON BASEMENT

LEVELS 1,2,3 AND LEVELS 1 AND 2

B. DRY ZONE – ALL FLOOR AREAS ON LEVEL 3,

THE ATTIC AND CONCEALED SPACES

C. WATER MIST EXTERIOR ZONE – AS SHOWN,

MANUAL OPERATION FROM RELEASING PANEL

AND MAIN OFFICE ONLY.

D. WATER MIST ROOF ZONE – AS SHOWN,

MANUAL OPERATION FROM RELEASING PANEL

AND MAIN OFFICE ONLY.

1. THE SYSTEM SHALL BE INSTALLED IN COMPLIANCE

WITH THE CURRENT STANDARD OF NATIONAL FIRE

PROTECTION ASSOCIATION (NFPA) #13. SYSTEM

MUST ALSO BE INSTALLED IN ACCORDANCE WITH THE

SECRETARY OF INTERIOR’S STANDARDS FOR

REHABILITATION. WHERE CONFLICT BETWEEN

STANDARDS APPEARS THE ENGINEER SHALL BE

CONTACTED FOR CONSULTATION.

2. ALL EXPOSED PIPING SHALL BE SCHEDULE 40 STEEL.

SCHEDULE 10 OR LIGHT WALL PIPE SHALL NOT BE

PERMITTED FOR ANY SIZE PIPE.

3. ALL STEEL FITTINGS SHALL BE THREADED. CUT

GROOVE FITTINGS MAY BE PERMITTED FOR 4 INCH

AND LARGER SIZE WHERE ACCESS IS ACHIEVABLE.

ROLLED GROOVE FITTINGS SHALL NOT BE

PERMITTED.

4. CPVC PIPING SHALL BE PERMITTED ON WET ZONES

AS SHOWN ON THE DRAWINGS. THE ENGINEER SHALL

BE CONTACTED IF QUESTIONS ARISE REGARDING

WHERE CPVC IS ACCEPTABLE.

5. EXTERIOR WATER MIST PIPING SHALL BE TYPE L

COPPER.

FIRE SPRINKLER GENERAL NOTES

8. ALL COMPONENTS SHALL BE COORDINATED

WITH OTHER TRADES.

9. THE EXISTING PIPE SECTIONS SHALL BE

MAINTAINED OPERATIONAL AS LONG AS

POSSIBLE. THE OBJECTIVE IS TO MAINTAIN EACH

AREA UNTIL THE NEW SYSTEM WITHIN THE

RESPECTIVE AREA IS ACTIVATED TO MAINTAIN

PROTECTION.

10. THE SYSTEM SHALL BE CONNECTED TO THE

FIRE ALARM SYSTEM AS EACH AREA IS

COMPLETED AND BECOMES OPERATIONAL.

11. DRY-PIPE SYSTEMS

1. JOINTS SHALL BE THREADED OR CUT

GROOVE. ROLLED GROOVE FITTINGS NOT

PERMITTED.

2. ALL PENDENT SPRINKLERS SHALL BE DRY

MODELS

3. ALL PIPING SHALL BE SLOPED TO MAIN

RISER OR TO CLEARLY ACCESSED

AUXILIARY LOCATIONS. LOW POINT

DRAINS SHALL BE MINIMIZED.

1 – EXISTING 6 INCH WATER SERVICE FLANGED FITTING FROM RESERVOIR

2 – DOUBLE CHECK VALVE WITH SHUT OFF VALVES

3 – WET ZONE ALARM VALVE WITH SHUT OFF VALVES, FLOW ALARM SWITCH

AND MAIN DRAIN

4 – TO WET SPRINKLER ZONE

5 - DRY ZONE VALVE WITH TRIM, SHUT OFF VALVE, FLOW ALARM PRESSURE

SWITCH, MAIN DRAIN

6 – TO DRY PIPE SPRINKLER ZONE

7 – EXTERIOR MIST DELUGE VALVE WITH TRIM, MANUAL AND RELEASING

PANEL CONTROL, DRAIN

8 – TO EXTERIOR MIST ZONE

9 – ROOF DELUGE VALVE WITH TRIM, MANUAL AND RELEASING PANEL

CONTROL, DRAIN

10 – TO ROOF ZONE

11 - 4 INCH FROM FDC

12 – CHECK VALVE

13 – FDC DRAIN

14 – MANIFOLD DRAIN LINE

15 – DRAIN TO EXTERIOR

16 – EXTERIOR MIST RELEASING PANEL

17 – EXTERIOR MIST MANUAL RELEASE WITH INFORMATION SIGN

18 – ROOF SPRINKLER RELEASING PANEL

19 – ROOF SPRINKLER MANUAL RELEASE WITH INFORMATION SIGN

20- MAIN DRAIN FROM ATTIC

21 - DISCHARGE TO EXTERIOR

NOTE: ALL VALVES TO BE ELECTRONICALLY TAMPER PROTECTED EXCEPT

DRAINS THAT MAY BE LOCKED IN NORMAL PLACEMENT.

FIRE SPRINKLER MAIN MANIFOLD

MAIN SPRINKLER MANIFOLD DETAIL

TYPICAL OPEN FRAME CEILING

SPRINKLERS

TYPICAL CEILING SPRINKLERS

ATTIC DETAIL

U.S. NATIONAL PARK SERVICE OREGON

CAVE CHATEAU EXTERIOR MIST

PROTECTION

HYDRAULIC CALCULATION INFORMATION

REMOTE AREA #1 - MAIN ATTIC

OCCUPANCY CALCULATION: LIGHT HAZARD

DENSITY: 0.10 gpm/sqft for 1,500 sqft TOTAL HOSE STREAMS: 300 gpm

TOTAL HEADS FLOWING: 7

K FACTOR: 4.2

TOTAL WATER REQUIRED: 392.7 gpm TOTAL PRESSURE REQUIRED: 53.6 psi

SAFETY MARGIN - PSI: +90.9 (62%)

HYDRAULIC CALCULATION INFORMATION

REMOTE AREA #2 - SIDE ATTICS

OCCUPANCY CALCULATION: LIGHT HAZARD

DENSITY: 0.10 gpm/sqft for 1,500 sqft TOTAL HOSE STREAMS: 100 gpm

TOTAL HEADS FLOWING: 6

K FACTOR: 5.6

TOTAL WATER REQUIRED: 201.6 gpm TOTAL PRESSURE REQUIRED: 64.9 psi

SAFETY MARGIN - PSI: +78.3 (54.7%)

HYDRAULIC CALCULATION INFORMATION

REMOTE AREA #3 - ROOF MIST NOZZLES

OCCUPANCY CALCULATION: N/A

DENSITY: N/A

TOTAL HOSE STREAMS: 100 gpm

TOTAL HEADS FLOWING: ALL

K FACTOR: 0.63

TOTAL WATER REQUIRED: 129.5 gpm TOTAL PRESSURE REQUIRED: 117 psi

SAFETY MARGIN - PSI: +27.3 (18.9%)

HYDRAULIC CALCULATION INFORMATION

REMOTE AREA #4 - ROOF MIST NOZZLES

OCCUPANCY CALCULATION: N/A

DENSITY: N/A

TOTAL HOSE STREAMS: 100 gpm

TOTAL HEADS FLOWING: 30

K FACTOR: 0.94

TOTAL WATER REQUIRED: 440.45 gpm TOTAL PRESSURE REQUIRED: 96.7 psi

SAFETY MARGIN - PSI: +48.2 (33.3%)

SCALE: NO SCALE

210211

FIRE SUPPRESSION LEGEND

STANDARD RESPONSE PENDANT

SPRINKLER - VIKING VK102 K-5.6

STANDARD RESPONSE UPRIGHT

SPRINKLER - VIKING VK100 K-5.6

QUICK RESPONSE CONCEALED PENDANT

SPRINKLER - VIKING VK 462

QUICK RESPONSE DRY PENDANT

SPRINKLER - VIKING VK482 K-5.6

HORIZONTAL SIDEWALL SPRINKLER -

VIKING VK104 K-5.6

CONCEALED HORIZONTAL SPRINKLER -

VIKING VK481 K-5.6

QUICK RESPONSE VERTICAL SIDEWALL

SPRINKLER VIKING VK106 K-5.6

WATER MIST NOZZLE - TELESTO MIST

CURTAIN K1/K2

RISER

ATTIC SPRINKLER VIKING V-BB 200 DEG. F

TELESTO ROOF MIST NOZZLE NGW P62

FIRE HOSE CABINET

STEEL SCHEDULE 40 PIPE

CPVC PIPE

COPPER TUBE

NC

NB

NA

ND

SC

SB

SA

SE

CB

SD

NA.4

NB.3

SA.3

SB.8

1.1

2.9

SA.1 NA.1

3.2 5.8

4.0

3.0

4.0

3.0

1.0

4.0

1.0

4.0

3.01.25

1.0 4.0

1.0

1.0

1.25

1.0

1.0

1.0

4.04.0

6" MAIN WATER SUPPLY

1.0 1.0

1.01.0

1.01.0

1.0

1.25

2.0

1.0

1.0

3.0

1.0

3.0

3.0

1.0

2.5

1.251.0

1.0

NON-ACCESSIBLE SPACE

NO A/S

1.0

1.25 1.0 1.0

2.01.5

2.0

1.0

1.0

1.25

4.0

4.0 1.5

3.0 4.0

FS2.05

3.0

3.0

3.0

1.5

4.0

MIST NOZZLE K20MIST NOZZLE K2P

1.0 1.25 2.5

1.5

3.0

4.0

MECHANICAL

B301

FHC-3-A

0 4 84

SCALE OF FEET

SCALE I

TITLE OF SHEETSUB SHEET NO.DESIGNED:

TECH REVIEW:

DATE:

DRAWING NO.

PMIS/PKG. NO.

SHEET

OF

138578

150025

OREGON CAVES NATIONAL MONUMENT

OREGON CAVES CHATEAU

R E

V

IT

/1

/2

:1

:5

P M

C U s e rs

\s w b ra

\D o c u m e n ts \0

-W o rk

\C lie n ts

\H P

G \P

R O

J E

C T

S \O

R C

A \R e v it \O

R C

A

F

IR

E

S U

P R

E S

S

IO

N .r v t

N.A.

B.S.

N.A.

9/13/2019

BASEMENT LEVEL 3 FIRE

SUPPRESSIONFS2.B3

135 210

CONSTRUCTION DRAWINGS

F S

.B

B

.S

BLDG.

TRUE

NORTH

29.6°

1. ALL PIPE ON THIS LEVEL TO BE SCHEDULE

40 STEEL EXCEPT MIST TUBE THAT SHALL

BE COPPER.

2. SEE DETAIL FS2.00/1 FOR MANIFOLD

LAYOUT

3. EXISTING 6 INCH WATER SUPPLY WITH

FLANGED FITTING FROM RESERVOIR

4. CRAWL SPACE TO BE INSULATED TO

PREVENT FREEZING

5. NEW SPRINKLERS TO BE INSTALLED

PARALLEL TO EXISTING TO MAINTAIN

PROTECTION AS LONG AS POSSIBLE

6. ELEVATOR PIT SPRINKLER WITH SHUT OFF

175°F (79°C) WITH GUARD

7. ALL MECHANICAL ROOM SPRINKLERS TO

BE 175°F (79°C) BRONZE FINISH WITH

GUARDS

8. ALL CRAWL SPACE SPRINKLERS TO BE

175°F (79°C) BRONZE FINISH WITH GUARDS

9. STAIRWAY SPRINKLERS TO BE 165°F (74°C)

CONCEALED SIDEWALL WITH WHITE FINISH

10. ALL MIST TUBE TO BE TYPE L COPPER

11. FINAL COMPONENT LOCATIONS TO BE

ENGINEER AND ARCHITECT APPROVED

12. DRAIN TO EXTERIOR BY MAIN-3 BASEMENT

ENTRANCE DOOR.

FIRE SUPRESSION GENERAL NOTES

1 EXISTING 6 INCH WATER SUPPLY WITH

FLANGED FITTING FROM RESERVOIR.

2 MAIN MANIFOLD SEE DETAIL 1-1 ON SHEET

FS2.00-P1

3 MAIN DRAIN 1.5

4 RISER 2A (WET) 4.0

5 RISER 3A (DRY) 4.0

6 RISER 5A EXTERIOR MIST 3.0

7 RISER 8A EXTERIOR ROOF 3.0

8 FIRE DEPARTMENT PUMPING LINE 4" DOWN

TO CRAWL SPACE.

9 SPRINKLER UNDER STAIR LANDING

10 UP TO LEVEL 2

11 ELEVATOR PIT SPRINKLER WITH SHUTOFF

175 DEG.F. (79 DEG.C) WITH GUARD.

12 RISER 4A EXTERIOR MIST 1.5

13 RISER 1A (WET) 4.0

14 EXPOSED EXTERIOR MIST COPPER TUBE.

FIRE SUPPRESSION

SHEET FS2.B3 SPECIFIC NOTES

NC

NB

NA

ND

SC

SB

SA

SE

CB

SD

NA.4

NB.3

SA.3

SB.8

1.1

2.9

SA.1 NA.1

3.2 5.8

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0 1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.0

1.51.5

1.25 3

1.25

1.25

1.25

1.25

1.25

2.0

2.5

2.5

2.5

2.5

2.0

2.0

1.0

FHC-2B

1.0

1.01.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0 1.0

FHC-2A

1.0

1.0

1.5

1.25

1.5

1.0

1.0

1.25

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.25 1.01.0

1.25

1.0 1.5

1.5

1.5

2.0

1.0

1.25 1.5

1.0

1.0

1.5 1.25

1.0

2.5

4.0

3.03.0

2.0

1.0

1.0

1.0

1.0

RISER 7A MIST 2.5

1.01.0

1.0

MIST NOZZLE K2M

1.25 3.0

MIST NOZZLE K2L

MIST NOZZLE K2K

1.5

1.0 1.25

1.5

1.5

1.5

WINE STORAGE

B202B

STAIRS

B200

MIST NOZZLE K2N

LAUNDRY

B209B

SERVICE ENTRY

B209

CLOSET

B209A

STORAGE

B211C

STORAGE

B211

ELEVATOR

ELEV.MACHINE RM

B211B

ELECTRIC ROOM

B211A

MECHANICAL

B301

MECHANICAL

B301

CORRIDOR

B201A

MECHANICAL

B301

MECHANICAL

B301

STORAGE

B202

STORAGE

B203

CORRIDOR

B201A

STAFF LOUNGE

B204

BATHROOM

B204B-1 BATHROOM

B204B-1

STAFF BEDROOM #3

B205

STAFF BEDROOM #2

B206

STAFF BEDROOM #1

B207

MECHANICAL

B301

1.5

FIRE SUPPRESSION LEGEND

STANDARD RESPONSE PENDANT

SPRINKLER - VIKING VK102 K-5.6

STANDARD RESPONSE UPRIGHT

SPRINKLER - VIKING VK100 K-5.6

QUICK RESPONSE CONCEALED PENDANT

SPRINKLER - VIKING VK 462

QUICK RESPONSE DRY PENDANT

SPRINKLER - VIKING VK482 K-5.6

HORIZONTAL SIDEWALL SPRINKLER -

VIKING VK104 K-5.6

CONCEALED HORIZONTAL SPRINKLER -

VIKING VK481 K-5.6

QUICK RESPONSE VERTICAL SIDEWALL

SPRINKLER VIKING VK106 K-5.6

WATER MIST NOZZLE - TELESTO MIST

CURTAIN K1/K2

RISER

ATTIC SPRINKLER VIKING V-BB 200 DEG. F

TELESTO ROOF MIST NOZZLE NGW P62

FIRE HOSE CABINET

STEEL SCHEDULE 40 PIPE

CPVC PIPE

COPPER TUBE

0 4 84

SCALE OF FEET

SCALE I

TITLE OF SHEETSUB SHEET NO.DESIGNED:

TECH REVIEW:

DATE:

DRAWING NO.

PMIS/PKG. NO.

SHEET

OF

138578

150025

OREGON CAVES NATIONAL MONUMENT

OREGON CAVES CHATEAU

R E

V

IT

/1

/2

:1

:5

P M

C U s e rs

\s w b ra

\D o c u m e n ts \0

-W o rk

\C lie n ts

\H P

G \P

R O

J E

C T

S \O

R C

A \R e v it \O

R C

A

F

IR

E

S U

P R

E S

S

IO

N .r v t

N.A.

B.S.

N.A.

9/13/2019

BASEMENT LEVEL 2 FIRE

SUPPRESSIONFS2.B2

136 210

CONSTRUCTION DRAWINGS

F S

.B

B

.S

BLDG.

TRUE

NORTH

29.6°

1. ALL PIPE ON THIS LEVEL TO BE SCHEDULE 40

STEEL AS SHOWN ON PLAN

2. NEW SPRINKLERS TO BE INSTALLED PARALLEL TO

EXISTING TO MAINTAIN PROTECTION AS LONG AS

POSSIBLE

3. ALL STORAGE ROOM AND UTILITY SPACE

SPRINKLERS TO BE 165°F (74°C) BRONZE FINISH

WITH GUARDS

4. ALL LOUNGE AND BEDROOM AREA SPRINKLERS

TO BE 155°F (68°C) WITH WHITE FINISH COVER

PLATES

5. STAIRWAY SPRINKLERS TO BE 165°F (74°C)

CONCEALED SIDEWALL WITH WHITE FINISH

6. REFLECTED CEILING PLAN SHOWN FOR

SPRINKLER HEAD PLACEMENT. PIPE TO BE RUN

ABOVE DROP CEILINGS WHERE THEY ARE

LOCATED. PLACE SPRINKLERS TYPICALLY IN THE

CENTER OF TILES.

7. ALL BEAM PENETRATIONS SHALL BE APPROVED

BY THE STRUCTURAL ENGINEER.

8. ALL MIST TUBE TO BE TYPE L COPPER.

9. FINAL COMPONENT LOCATIONS TO BE ENGINEER

AND ARCHITECT APPROVED

FIRE SUPPRESSSION GENERAL NOTES

1 RISER 1A (WET) 4.0

2 RISER 4A EXTERIOR MIST 1.5

3 1.0 UP FROM LEVEL B3

4 MAIN DRAIN 1.5

5 RISER 2B (WET) 4.0

6 RISER 3B (DRY) 4.0

7 RISER 5B EXTERIOR MIST 3.0

8 RISER 8B EXTERIOR ROOF 3.0

9 RISER 2A (WET) 4.0

10 RISER 3A (DRY) 4.0

11 RISER 5A EXTERIOR MIST 3.0

12 RISER 8A EXTERIOR ROOF 3.0

13 COORDINATE FIRE RISERS WITH

PLUMBING RISERS IN CAVITY SPACE.

14 FINAL LOCATION FOR REFRIGERATOR

DRY PENDANT SPRINKLERS TO BE

FIELD ESTABLISHED. SPRINKLER

BARELS TO BE FIELD MEASURED.

FIRE SUPPRESSION

SHEET FS2.B2 SPECIFIC NOTES

NC

NB

NA

ND

SC

SB

SA

SE

CB

SD

NA.4

NB.3

SA.3

SB.8

1.1

2.9

SA.1 NA.1

3.2 5.8

RISER 1B (WET 4")

1.0

1.0 2.0

2.0

1.0

2.0

1.0

2.0 1.0

1.0

1.0

1.0 2.0

1.0

2.0

1.0 3.0

2.0

1.5

1.0

1.0

2.0

1.0

2.0

1.25

2.0

1.0

1.25

1.0 1.0

1.0

1.0 1.0

1.0

1.01.0

1.25

1.01.0

1.5

1.0

1.01.01.01.01.01.25

1.0

1.0

1.0

1.5

1.5

4.0

4.0

1.01.0

4.0

FHC-1A

2.03.0

1.5

1.01.01.01.0

1.25

RISER 7A MIST

FHC-1B

1.0

4.0

4.0

1.0

1.0

1.25

1.0

1.0

1.25

4.0

1.25

1.0

1.0

1.25

1.0

2.0

1.0

1.0

1.0

1.0

1.0

MIST NOZZLE

MIST NOZZLE K2IMIST NOZZLE

K2J

MIST NOZZLE

K1F

1.0

1.0

1.0

1.0

1.0

1.5

4.0

COFFEE SHOP

B104

KITCHEN

B103

1.5

1.01.01.0

1.5

BALCONY

DINING ROOM

B102

GIFT SHOP

B101

WOMENS RESTROOM

B101A

MENS ROOM

B101B

GIFT SHOP

B101

ELEVATOR

STORAGE

B100A

FIRE SUPPRESSION LEGEND

STANDARD RESPONSE PENDANT

SPRINKLER - VIKING VK102 K-5.6

STANDARD RESPONSE UPRIGHT

SPRINKLER - VIKING VK100 K-5.6

QUICK RESPONSE CONCEALED PENDANT

SPRINKLER - VIKING VK 462

QUICK RESPONSE DRY PENDANT

SPRINKLER - VIKING VK482 K-5.6

HORIZONTAL SIDEWALL SPRINKLER -

VIKING VK104 K-5.6

CONCEALED HORIZONTAL SPRINKLER -

VIKING VK481 K-5.6

QUICK RESPONSE VERTICAL SIDEWALL

SPRINKLER VIKING VK106 K-5.6

WATER MIST NOZZLE - TELESTO MIST

CURTAIN K1/K2

RISER

ATTIC SPRINKLER VIKING V-BB 200 DEG. F

TELESTO ROOF MIST NOZZLE NGW P62

FIRE HOSE CABINET

STEEL SCHEDULE 40 PIPE

CPVC PIPE

COPPER TUBE

0 4 84

SCALE OF FEET

SCALE I

TITLE OF SHEETSUB SHEET NO.DESIGNED:

TECH REVIEW:

DATE:

DRAWING NO.

PMIS/PKG. NO.

SHEET

OF

138578

150025

OREGON CAVES NATIONAL MONUMENT

OREGON CAVES CHATEAU

R E

V

IT

/1

/2

:1

:5

P M

C U s e rs

\s w b ra

\D o c u m e n ts \0

-W o rk

\C lie n ts

\H P

G \P

R O

J E

C T

S \O

R C

A \R e v it \O

R C

A

F

IR

E

S U

P R

E S

S

IO

N .r v t

N.A.

B.S.

N.A.

9/13/2019

BASEMENT LEVEL 1 FIRE

SUPPRESSIONFS2.B1

137 210

CONSTRUCTION DRAWINGS

F S

.B

B

.S

1. UNLESS OTHERWISE NOTED ALL SPRINKLER PIPE TO BE RUN

ABOVE CEILING.

2. ALL MAINS TO BE SCHEDULE 40 STEEL

3. KITCHEN SPRINKLER PIPE TO BE EXPOSED, SCHEDULE 40 STEEL

AS SHOWN ON PLAN.

4. DINING ROOM, GIFT SHOP AND COFFEE SHOP PIPE TO BE CPVC

PLASTIC AS SHOWN ON PLAN

5. NEW SPRINKLERS TO BE INSTALLED PARALLEL TO EXISTING TO

MAINTAIN PROTECTION AS LONG AS POSSIBLE

6. ALL STORAGE ROOM, KITCHEN AND UTILITY SPACE SPRINKLERS

TO BE 165°F (74°C) BRONZE FINISH WITH GUARDS

7. ALL PUBLIC SPACE (DINING ROOM, COFFEE SHOP AND GIFT SHOP

SPRINKLERS TO BE 155°F (68°C), FLUSH PLATE CONCEALED WITH

ARCHITECT APPROVED SPECIAL FINISH COLOR COVER PLATES

8. RESTROOM SPRINKLERS TO BE 155°F (68°C), FLUSH PLATE

CONCEALED WITH ARCHITECT APPROVED WHITE FINISH COLOR

COVER PLATES

9. STAIRWAY SPRINKLERS TO BE 165°F (74°C) FLUSH PLATE

CONCEALED SIDEWALL WITH ARCHITECT APPROVED SPECIAL

FINISH COLOR.

10. REFLECTED CEILING PLAN SHOWN FOR SPRINKLER HEAD

PLACEMENT. PIPE TO BE RUN ABOVE DROP CEILINGS WHERE

THEY ARE LOCATED. PLACE SPRINKLERS TYPICALLY IN THE

CENTER OF TILES.

11. ALL BEAM PENETRATIONS SHALL BE APPROVED BY THE

STRUCTURAL ENGINEER.

12. ALL MIST TUBE TO BE TYPE L COPPER

13. FINAL LOCATIONS TO BE ENGINEER AND ARCHITECT APPROVED.

FIRE SPRINKLER NOTES x

BLDG.

TRUE

NORTH

29.6°

1 RISER 4A EXTERIOR MIST

2 RISER 1A (WET)

3 1.0 UP FROM LEVEL B3

4 1.0 UP TO LEVEL 1

5 MAIN DRAIN 1.5

6 RISER 2C (WET) 4.0

7 RISER 3C (DRY) 4.0

8 RISER 5C EXTERIOR MIST 3.0

9 RISER 8C EXTERIOR ROOF 3.0

10 RISER 2B (WET) 4.0

11 RISER 3B (DRY) 4.0

12 RISER 5B EXTERIOR MIST 3.0

13 RISER 8B EXTERIOR ROOF 3.0

14 FIRE DEPARTMENT PUMPING LINE

4" DOWN TO CRAWL SPACE.

FIRE SUPPRESSION

SHEET FS2.B1 SPECIFIC NOTES

NC

NB

NA

ND

SC

SB

SA

SE

SD

NA.4

NB.3

SA.3

SB.8

1.1

2.9

SA.1 NA.1

3.2 5.8

RISER 1B (WET) 4"

FHC-1A

1.0

2.5

2.5

2.5

1.0

1.02.5

2.5

1.0 1.0

2.5

1.0

1.0

2.5

1.0

1.0

2.5

1.0

1.0

1.0

1.0

2.5

2.5

1.0

1.0

1.0

1.0

1.5

1.5

1.0

1.0

1.0

2.5

1.0

1.0

2.5

1.0

1.0

3.0

3.0

1.0 1.0

1.0

1.0

3.0

1.0

2.0

2.0 2.0

1.0

2.0

2.0

2.0

2.0

1.01.0

1.0

1.0

2.0

2.0

1.0 1.0

2.0

1.0 1.0

3"

3"

1.0

2.5

1.0

1.0

2.5

1.0

2.5

FHC-1B

1.0 3.0

4.0 3.0

1.0 1.0

2.5

2.5

1.0

1.0

2.5

1.0

2.51.0

2.51.0

2.5

1.0

2.5

1.0

2.5 1.0

1.0 2.5

1.0 2.5

1.0

2.5

1.0 2.5

1.0 2.5

1.0

1.0

2.5 1.0

2.5

1.0

2.5

1.0

2.5

1.0 2.5

2.5

K1B

K1E

RISER 7A MIST 2.5

2.5

4.0

MIST NOZZLE K2H MIST NOZZLE K2G

1.0

1.0 1.0

1.5

OFFICE #1

OFFICE #2

LOBBY

GAME ROOM

CORRIDOR

SITTING ROOM

LINEN

GUESTROOM

BATHROOM

105A

GUESTROOM

BATHROOM

103A

BATHROOM

104A

GUESTROOM

GUESTROOM

GUESTROOM

BATHROOM

102A

BATHROOM

101A

LOBBY

SITTING ROOM

FIRE SUPPRESSION LEGEND

STANDARD RESPONSE PENDANT

SPRINKLER - VIKING VK102 K-5.6

STANDARD RESPONSE UPRIGHT

SPRINKLER - VIKING VK100 K-5.6

QUICK RESPONSE CONCEALED PENDANT

SPRINKLER - VIKING VK 462

QUICK RESPONSE DRY PENDANT

SPRINKLER - VIKING VK482 K-5.6

HORIZONTAL SIDEWALL SPRINKLER -

VIKING VK104 K-5.6

CONCEALED HORIZONTAL SPRINKLER -

VIKING VK481 K-5.6

QUICK RESPONSE VERTICAL SIDEWALL

SPRINKLER VIKING VK106 K-5.6

WATER MIST NOZZLE - TELESTO MIST

CURTAIN K1/K2

RISER

ATTIC SPRINKLER VIKING V-BB 200 DEG. F

TELESTO ROOF MIST NOZZLE NGW P62

FIRE HOSE CABINET

STEEL SCHEDULE 40 PIPE

CPVC PIPE

COPPER TUBE

0 4 84

SCALE OF FEET

SCALE I

TITLE OF SHEETSUB SHEET NO.DESIGNED:

TECH REVIEW:

DATE:

DRAWING NO.

PMIS/PKG. NO.

SHEET

OF

138578

150025

OREGON CAVES NATIONAL MONUMENT

OREGON CAVES CHATEAU

R E

V

IT

/1

/2

:1

:4

P M

C U s e rs

\s w b ra

\D o c u m e n ts \0

-W o rk

\C lie n ts

\H P

G \P

R O

J E

C T

S \O

R C

A \R e v it \O

R C

A

F

IR

E

S U

P R

E S

S

IO

N .r v t

N.A.

B.S.

N.A.

9/13/2019

LEVEL 1 FIRE

SUPPRESSIONFS2.01

138 210

CONSTRUCTION DRAWINGS

F S

.0

B

.S

1. UNLESS OTHERWISE NOTED ALL SPRINKLER

PIPE TO BE RUN ABOVE CEILING. SEE DETAIL

2.00/3

2. ALL MAINS TO BE SCHEDULE 40 STEEL AS SHOWN

ON PLAN.

3. LOUNGE, OFFICE AND GUEST ROOMS PIPE TO BE

CPVC PLASTIC AS SHOWN ON PLAN.

4. NEW SPRINKLERS TO BE INSTALLED PARALLEL TO

EXISTING TO MAINTAIN PROTECTION AS LONG AS

POSSIBLE

5. ALL PUBLIC SPACE AND GUEST ROOM SPRINKLERS

TO BE 155°F (68°C), FLUSH PLATE CONCEALED

WITH ARCHITECT APPROVED SPECIAL FINISH

COLOR COVER PLATES

6. RESTROOM SPRINKLERS TO BE 155°F (68°C),

FLUSH PLATE CONCEALED WITH ARCHITECT

APPROVED WHITE FINISH COLOR COVER PLATES

7. STAIRWAY SPRINKLERS TO BE 165°F (74°C) FLUSH

PLATE CONCEALED SIDEWALL WITH ARCHITECT

APPROVED SPECIAL FINISH COLOR.

8. REFLECTED CEILING PLAN SHOWN FOR SPRINKLER

HEAD PLACEMENT. PIPE TO BE RUN ABOVE DROP

CEILINGS WHERE THEY ARE LOCATED. PLACE

SPRINKLERS TYPICALLY IN THE CENTER OF TILES.

9. ALL BEAM PENETRATIONS SHALL BE APPROVED BY

THE STRUCTURAL ENGINEER.

10. ALL MIST TUBE TO BE TYPE L COPPER

11. FINAL COMPONENT LOCATIONS TO BE ENGINEER

AND ARCHITECT APPROVED

FIRE SPRINKLER NOTES x

BLDG.

TRUE

NORTH

29.6°

1 MAIN DRAIN 1.5

2 RISER 2C (WET) 4.0

3 RISER 3C (DRY) 4.0

4 RISER 5C EXTERIOR MIST 3.0

5 RISER 8C EXTERIOR ROOF 3.0

6 RISER 1C (WET) 3.0

7 1.0 FROM LEVEL 1

8 FIRE DEPARTMENT PUMPING LINE 4"

DOWN TO CRAWL SPACE.

9 FIRE DEPARTMENT PUMPING

CONNECTION (F.D.C)

FIRE SUPPRESSION

SHEET FS2.01 SPECIFIC NOTES

NC

NB

NA

ND

SC

SB

SA

SE

SD

NA.4

NB.3

SA.3

SB.8

1.1

2.9

SA.1 NA.1

3.2 5.8

EXTERIOR MIST NOZZLES

(TYP)

MIST NOZZLE K2E

FHC-2A

FHC-2B

1.2

2.5

2.5

1.2

1.0

1.0

2.5

2.5

1.0

1.0

1.0

1.0

2.5

2.5

1.0

1.0

2.5

1.0 1.0

1.0

1.0 2.5

2.5

1.0

2.51.0

1.0 1.0

1.0

2.5

1.0

1.0

2.5 2.5

2.5

2.5

RUN ALONG RAFTERS

1.0 1.0 1.0

1.25

1.0 1.0 1.0

1.01.01.25

1.0

1.01.01.251.5

1.0

2.0 2.5

2.0

2.0

1.0

1.5

1.0

2.5

1.01.0

3.0 1.0

1.0

1.0

2.5

2.5

1.0

2.5

2.5

2.5

1.0

1.0

1.0

1.0

2.5

2.5

1.0

1.0

2.5

2.5

1.0 1.0

2.5

1.0

1.0

1.0

2.5

2.5 1.0

2.5 2.5

1.0

1.0

1.0

2.5

1.0

2.5

2.5

2.5

1.0

2.5

2.5

2.5

RISER 1C (WET)3.0

3.0

2.5

2.5

MIST NOZZLE K2F

MIST NOZZLE K3D

2.5 2.5 2.5

2.5

2.5

2.5

2.5

1.0 1.5 1.0

2.0

2.0

STAIRS

BATHROOM

214A

BATHROM

204A

BATHROOM

203A

BATHROOM

201A

BATHROOM

212A

BATHROOM

210A

BATHROOM

209A

STAIRS

BATHROOM

211A

STORAGE

200C

CORRIDOR

200B

BATHROOM

206A

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

BATHROOM

209A

LOBBY

STAIRS

UP TO

FHC-3A 1"UP

1.0

FIRE SUPPRESSION LEGEND

STANDARD RESPONSE PENDANT

SPRINKLER - VIKING VK102 K-5.6

STANDARD RESPONSE UPRIGHT

SPRINKLER - VIKING VK100 K-5.6

QUICK RESPONSE CONCEALED PENDANT

SPRINKLER - VIKING VK 462

QUICK RESPONSE DRY PENDANT

SPRINKLER - VIKING VK482 K-5.6

HORIZONTAL SIDEWALL SPRINKLER -

VIKING VK104 K-5.6

CONCEALED HORIZONTAL SPRINKLER -

VIKING VK481 K-5.6

QUICK RESPONSE VERTICAL SIDEWALL

SPRINKLER VIKING VK106 K-5.6

WATER MIST NOZZLE - TELESTO MIST

CURTAIN K1/K2

RISER

ATTIC SPRINKLER VIKING V-BB 200 DEG. F

TELESTO ROOF MIST NOZZLE NGW P62

FIRE HOSE CABINET

STEEL SCHEDULE 40 PIPE

CPVC PIPE

COPPER TUBE

0 4 84

SCALE OF FEET

SCALE I

TITLE OF SHEETSUB SHEET NO.DESIGNED:

TECH REVIEW:

DATE:

DRAWING NO.

PMIS/PKG. NO.

SHEET

OF

138578

150025

OREGON CAVES NATIONAL MONUMENT

OREGON CAVES CHATEAU

R E

V

IT

/1

/2

:1

:4

P M

C U s e rs

\s w b ra

\D o c u m e n ts \0

-W o rk

\C lie n ts

\H P

G \P

R O

J E

C T

S \O

R C

A \R e v it \O

R C

A

F

IR

E

S U

P R

E S

S

IO

N .r v t

N.A.

B.S.

N.A.

9/13/2019

LEVEL 2 FIRE

SUPPRESSIONFS2.02

139 210

CONSTRUCTION DRAWINGS

F S

.0

B

.S

BLDG.

TRUE

NORTH

29.6°

1. UNLESS OTHERWISE NOTED ALL SPRINKLER

PIPE TO BE RUN ABOVE CEILING.

3. ALL MAINS TO BE SCHEDULE 40 STEEL AS

SHOWN ON PLAN

4. GUEST ROOMS PIPE TO BE CPVC PLASTIC AS

SHOWN ON PLAN.

5. NEW SPRINKLERS TO BE INSTALLED

PARALLEL TO EXISTING TO MAINTAIN

PROTECTION AS LONG AS POSSIBLE

6. ALL GUEST ROOM AND CORRIDOR

SPRINKLERS TO BE 155°F (68°C), FLUSH

PLATE CONCEALED WITH ARCHITECT

APPROVED SPECIAL FINISH COLOR COVER

PLATES

7. STAIRWAY SPRINKLERS TO BE 165°F (74°C)

FLUSH PLATE CONCEALED SIDEWALL WITH

ARCHITECT APPROVED SPECIAL FINISH

COLOR.

8. REFLECTED CEILING PLAN SHOWN FOR

SPRINKLER HEAD PLACEMENT. PIPE TO BE

RUN ABOVE DROP CEILINGS WHERE THEY

ARE LOCATED. PLACE SPRINKLERS

TYPICALLY IN THE CENTER OF TILES.

9. ALL BEAM PENETRATIONS SHALL BE

APPROVED BY THE STRUCTURAL ENGINEER.

10. FINAL COMPONENT LOCATIONS TO BE

ENGINEER AND ARCHITECT APPROVED

11. ALL MIST TUBE TO BE TYPE L COPPER

FIRE SUPRESSION NOTES

1 MAIN DRAIN 1.5

2 RISER 2C (WET) 4.0

3 RISER 3C (DRY) 4.0

4 RISER 5C EXTERIOR MIST 3.0

5 RISER 8C EXTERIOR ROOF 3.0

FIRE SUPPRESSION

SHEET FS2.02 SPECIFIC NOTES

SPRINKLER - VIKING VK102 K-5.6

STANDARD RESPONSE UPRIGHT

SPRINKLER - VIKING VK100 K-5.6

QUICK RESPONSE CONCEALED PENDANT

SPRINKLER - VIKING VK 462

QUICK RESPONSE DRY PENDANT

SPRINKLER - VIKING VK482 K-5.6

HORIZONTAL SIDEWALL SPRINKLER -

VIKING VK104 K-5.6

CONCEALED HORIZONTAL SPRINKLER -

VIKING VK481 K-5.6

QUICK RESPONSE VERTICAL SIDEWALL

SPRINKLER VIKING VK106 K-5.6

WATER MIST NOZZLE - TELESTO MIST

CURTAIN K1/K2

RISER

ATTIC SPRINKLER VIKING V-BB 200 DEG. F

TELESTO ROOF MIST NOZZLE NGW P62

FIRE HOSE CABINET

STEEL SCHEDULE 40 PIPE

CPVC PIPE

COPPER TUBE

NC

NB

NA

ND

SC

SB

SA

SE

SD

NA.4

NB.3

SA.3

SB.8

1.1

2.9

SA.1 NA.1

3.2 5.8

MIST NOZZLE K2AMIST NOZZLE K2C MIST NOZZLE K2B

1.0 1.0 1.0

LINEN

300C

BATHROOM

301A

BATHROOM

309A

BATHROOM

307A

BATHROOM

305A

BATHROOM

311A

BATHROOM

312A

STAIRS

BATHROOM

303A

BATHROOM

302A

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

CORRIDOR

GUESTROOM

EAVE

EAVE

EAVE

FHC-3A

1"FROM BELOW

LINEN

300C

CORRIDOR

1"FROM

BELOW

FHC-3B

FROM ABOVE

1.0

1.0

1.0 1.0

1.0

1.25

1.25 1.5

1.0

1.0

1.0

1.0

1.25

1.52.5

1.0

2.5

1.02.0 1.25

1.25

1.25

1.0

1.0

1.0 1.0

1.0

1.0

1.25

1.0

1.5

2.5 3.0

1.01.0

1.0

1.0 1.0

3.0 3.0 3.0 3.0

1.0 1.0

1.0 1.0 1.0 1.0 1.0

1.01.01.01.0

1.0 1.0 1.0 1.0 1.0

1.0

1.0

3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.5

1.0 1.0

4.0

1.0

1.0

1.0 1.0

1.0

1.25

1.251.0

1.0

1.25

1.25

1.25

2.0

2.0

2.0

1.5

1.0

1.5 1.25

1.0

1.0

1.25

1.0

1.0

1.0 1.0

1.0

0 4 84

SCALE OF FEET

SCALE I

TITLE OF SHEETSUB SHEET NO.DESIGNED:

TECH REVIEW:

DATE:

DRAWING NO.

PMIS/PKG. NO.

SHEET

OF

138578

150025

OREGON CAVES NATIONAL MONUMENT

OREGON CAVES CHATEAU

R E

V

IT

/1

/2

:1

:4

P M

C U s e rs

\s w b ra

\D o c u m e n ts \0

-W o rk

\C lie n ts

\H P

G \P

R O

J E

C T

S \O

R C

A \R e v it \O

R C

A

F

IR

E

S U

P R

E S

S

IO

N .r v t

N.A.

B.S

N.A.

9/13/2019

LEVEL 3 FIRE

SUPPRESSIONFS2.03

140 210

CONSTRUCTION DRAWINGS

F S

.0

B

.S

BLDG.

TRUE

NORTH

29.6°

1. UNLESS OTHERWISE NOTED ALL SPRINKLER PIPE

TO BE RUN ABOVE CEILING. SEE DETAIL 2.00/3

2. ALL PIPE TO BE SCHEDULE 40 STEEL

3. PITCH ALL PIPE TO DRAIN. ADD SUPPLEMENTAL

LOW POINT DRAINS WHERE NEEDED. LOW POINT

DRAINS SHALL BE ACCESSABLE.

4. NEW SPRINKLERS TO BE INSTALLED PARALLEL TO

EXISTING TO MAINTAIN PROTECTION AS LONG AS

POSSIBLE

5. ALL GUEST ROOM AND CORRIDOR SPRINKLERS TO

BE 155°F (68°C), FLUSH PLATE CONCEALED WITH

ARCHITECT APPROVED SPECIAL FINISH COLOR

COVER PLATES

6. STAIRWAY SPRINKLERS TO BE 165°F (74°C) FLUSH

PLATE CONCEALED SIDEWALL WITH ARCHITECT

APPROVED SPECIAL FINISH COLOR.

7. ALL CONCEALED AREA UPRIGHT SIDEWALL

SPRINKLERS TO BE 175°F (79°C)

8. REFLECTED CEILING PLAN SHOWN FOR SPRINKLER

HEAD PLACEMENT. PIPE TO BE RUN ABOVE DROP

CEILINGS WHERE THEY ARE LOCATED. PLACE

SPRINKLERS TYPICALLY IN THE CENTER OF TILES.

9. ALL BEAM PENETRATIONS SHALL BE APPROVED BY

THE STRUCTURAL ENGINEER.

FIRE SUPPRESSION NOTES

1 LOW POINT DRAIN

2 ACCESS DOOR

3 MAIN DRAIN 1.5

4 RISER 3C 4.0

5 RISER 5C EXTERIOR MIST 3.0

6 RISER 8C EXTERIOR ROOF 3.0

7 ROOF NOZZLE DRAIN VALVE/PORT

8 DRY ZONE INSPECTORS TEST DRAIN VALVE

9 MIST NOZZLES SUPPLIED FROM ATTIC.

10 RUN PIPE EXPOSE ABOVE DOOR FRAME

11 PLACE ALL RISERS TIGHT TO WALL TO AVOID

IMPACTING PASSAGEWAY.

12 RISER 2C (WET) 4.0

FIRE SUPPRESSION

SHEET FS2.03 SPECIFIC NOTES

SPRINKLER - VIKING VK102 K-5.6

STANDARD RESPONSE UPRIGHT

SPRINKLER - VIKING VK100 K-5.6

QUICK RESPONSE CONCEALED PENDANT

SPRINKLER - VIKING VK 462

QUICK RESPONSE DRY PENDANT

SPRINKLER - VIKING VK482 K-5.6

HORIZONTAL SIDEWALL SPRINKLER -

VIKING VK104 K-5.6

CONCEALED HORIZONTAL SPRINKLER -

VIKING VK481 K-5.6

QUICK RESPONSE VERTICAL SIDEWALL

SPRINKLER VIKING VK106 K-5.6

WATER MIST NOZZLE - TELESTO MIST

CURTAIN K1/K2

RISER

ATTIC SPRINKLER VIKING V-BB 200 DEG. F

TELESTO ROOF MIST NOZZLE NGW P62

FIRE HOSE CABINET

STEEL SCHEDULE 40 PIPE

CPVC PIPE

COPPER TUBE

CD

CC

NC

NB

NA

ND

SC

SB

SA

SE

CB

CA

SD

NA.4

NB.3

SA.3

SB.8

1.1

2.9

CD.9

SA.1 NA.1

6.1

A

NC

NB

NA

ND

SC

SB

SA

SE

SD

NA.4

NB.3

SA.3

SB.8

1.1

2.9

SA.1 NA.1

3.2 5.8

EXTERIOR MIST NOZZLE K1A

EXTERIOR MIST NOZZLE K1D

TO EXTERIOR MIST NOZZLE K2A

TO EXTERIOR MIST NOZZLE K2C TO EXTERIOR MIST NOZZLE K2B

1.5

1.5

1.0 1.0 1.0

2.0

1.5

1.0

3.0

2.5

3.03.0 1.0

1.5

1.0 1.0

2.0

1.01.0 2.5

2.02.0

1.5

1.5 2.5

1.0

1.0 1.0

2.0

2.5 2.5 2.5

1.0 1.0 1.0

1.25

1.0

1.0

1.5

1.25

1.5 1.5

1.0

1.0

2.0

1.0

1.0

1.25

1.5

1.0

1.0

1.0

1.0

1.25

1.5

1.5

3 4

3.03.03.03.03.03.03.0

GUESTROOM

GUESTROOM

GUESTROOM

GUESTROOM

TELESTO ROOF MIST

NOZZLE

ROOF

PROVIDE AUXILLARY

DRAINS FOR NOZZLE

SUPPLY TO PREVENT

TRAPPED WATER AT LOW

POINTS

TELESTO ROOF NOZZLE

ROOF

AUXILLARY LOW POINT DRAIN

0 4 84

SCALE OF FEET

SCALE I

TITLE OF SHEETSUB SHEET NO.DESIGNED:

TECH REVIEW:

DATE:

DRAWING NO.

PMIS/PKG. NO.

SHEET

OF

138578

150025

OREGON CAVES NATIONAL MONUMENT

OREGON CAVES CHATEAU

R E

V

IT

/1

/2

:1

:5

P M

C U s e rs

\s w b ra

\D o c u m e n ts \0

-W o rk

\C lie n ts

\H P

G \P

R O

J E

C T

S \O

R C

A \R e v it \O

R C

A

F

IR

E

S U

P R

E S

S

IO

N .r v t

N.A.

B.S.

N.A.

9/13/2019

ATTIC LEVEL FIRE

SUPPRESSIONFS2.04

141 210

CONSTRUCTION DRAWINGS

F S

.0

B

.S

BLDG.

TRUE

NORTH

29.6°

1. ALL ATTIC, THIRD FLOOR AND ROOF PIPE TO BE

SCHEDULE 40 STEEL AS SHOWN ON PLAN

2. ALL EXTERIOR MIST PIPE TO BE TYPE K COPPER

3. PITCH ALL PIPE TO DRAIN. ARROWS INDICATE

ASSUMED DIRECTION OF DRAIN. THIS IS TO BE

FIELD VERIFIED BY CONTRACTOR AND ADDITIONAL

DRAINS PROVIDED AS NEEDED. LOW POINT DRAINS

SHALL BE ACCESSIBLE AND APPROVED BY

ENGINEER.

4. NEW SPRINKLERS TO BE INSTALLED PARALLEL TO

EXISTING TO MAINTAIN PROTECTION AS LONG AS

POSSIBLE

5. ALL SPRINKLERS TO BE 200°F (93°C) BRONZE FINISH

6. ALL BEAM PENETRATIONS SHALL BE APPROVED BY

THE STRUCTURAL ENGINEER.

7. ACCESS TO THE WING ATTICS IS NOT FULLY KNOWN

AND CANNOT BE UNTIL CEILINGS ARE REMOVED.

8. CURRENT SPRINKLER LAYOUT IS SHOWN BASED ON

EXPECTED SITUATION BUT FINAL SPRINKLER

PLACEMENT WILL NEED TO BE UNDERTAKEN IN

CONSULTATION WITH THE ENGINEER AFTER

CEILINGS HAVE BEEN REMOVED.

9. ROOF MIST NOTE: FINAL LOCATIONS TO BE FIELD

VERIFIED IN CONSULTATION WITH ENGINEER

FIRE SUPPRESSION NOTES

FS2.04

2 ROOF DETAIL 1

FS2.04

3 ROOF DETAIL 2

1 DOTTED LINES REPRESENT APPROXIMATE MIST

SPRAY PATTERN

2 SEE DETAIL FS2.04/2 (TYPICAL)

3 MOST DEMANDING CALCULATED AREA - ATTIC

AREA #1

4 MAIN DRAIN 1.5 WITH ZONE DRAIN VALVES

5 RISER 3C (DRY) 4.0

6 RISER 5C EXTERIOR MIST 3.0

7 RISER 8C EXTERIOR ROOF 3.0

8 TO THIRD FLOOR ZONE

9 LOW POINT DRAIN SEE DETAIL FS2.04/3 (TYPICAL)

10 1 INCH DOWN TO ROOF DRAIN VALVE ON LEVEL 3.

11 1 INCH DOWN TO INSPECTOR'S TEST CONNECTION

ON LEVEL 3.

FIRE SUPPRESSION

SHEET FS2.04 SPECIFIC NOTES

LEVEL 1

0"

LEVEL 2

13' - 5"

ROOF

36' - 4"

BASEMENT 1

-12' - 3"

LEVEL 3

22' - 7"

BASEMENT 2

-24' - 0"

BASEMENT 3

-36' - 0"

5 4

LEVEL 1.1

2' - 4"

BASEMENT 2.1

-22' - 9"

3.25.8

ATTIC

31' - 4"

5 45 45.8

MIST NOZZLE K2K

MIST NOZZLE K1C

MIST NOZZLE K1B

MIST NOZZLE K2G MIST NOZZLE K2H MIST NOZZLE K1E

MIST NOZZLE K1D

MIST NOZZLE K1A

MIST NOZZLE K2A

MIST NOZZLE K2C

MIST NOZZLE K2FMIST NOZZLE K2D

MIST NOZZLE K2JMIST NOZZLE K2I

MIST NOZZLE K2MMIST NOZZLE K2L

MIST NOZZLE K2PMIST NOZZLE K2O

MIST NOZZLE K1F

MIST NOZZLE K2B

MIST NOZZLE K2E

TELESTO ROOF MIST

NOZZLES

SEE FS2.04 FOR LOCATIONS

MIST NOZZLE K2N

2 2 2

0 4 84

SCALE OF FEET

SCALE I

TITLE OF SHEETSUB SHEET NO.DESIGNED:

TECH REVIEW:

DATE:

DRAWING NO.

PMIS/PKG. NO.

SHEET

OF

138578

150025

OREGON CAVES NATIONAL MONUMENT

OREGON CAVES CHATEAU

R E

V

IT

/1

/2

:1

:5

P M

C U s e rs

\s w b ra

\D o c u m e n ts \0

-W o rk

\C lie n ts

\H P

G \P

R O

J E

C T

S \O

R C

A \R e v it \O

R C

A

F

IR

E

S U

P R

E S

S

IO

N .r v t

N.A.

B.S

N.A.

9/13/2019

EXTERIOR ELEVATION -

MIST FIRE SUPPRESSIONFS2.05

142 210

CONSTRUCTION DRAWINGS

F S

.0

B

.S

FS2.05

EXTERIOR ELEVATION - MIST FIRE

SUPPRESSION

1 SUPPLIED FROM ATTIC

2 SUPPLIED FROM SECOND FLOOR.

3 EXPOSED COPPER TUBE RUN TIGHT TO WALL AND

ABOVE WINDOWS TO MINIMIZE VISUAL IMPACT. FINAL

LOCATIONS TO BE ENGINEER AND ARCHITECT

APPROVED.

4 SUPPLIED FROM FIRST FLOOR.

5 ALL EXTERIOR TUBE TO BE TYPE L COPPER RUN ALONG

ROOF FRAMING UNDER EAVE. FINAL LOCATION TO BE

ENGINEER AND ARCHITECT APPROVED.

6 SUPPLIED FROM - 1 LEVEL.

7 SUPPLIED FROM - 2 LEVEL.

8 EXPOSED COPPER RISER. FINAL LOCATION TO BE

ENGINEER AND ARCHITECT APPROVED.

9 DECK SUPPLIED FROM - 3 LEVEL.

FIRE SUPPRESSION

SHEET FS2.05 SPECIFIC NOTES

ORCA_150025_FIRE SUPRESSION - Sheet - FA2-00 - FIRE DETECTION DETAILS
ORCA_150025_FIRE SUPRESSION - Sheet - FA2-01 - LEVEL 1 FIRE DETECTION AND NOTIFICATION SYSTEM
ORCA_150025_FIRE SUPRESSION - Sheet - FA2-02 - LEVEL 2 FIRE DETECTION AND NOTIFICATION SYSTEM
ORCA_150025_FIRE SUPRESSION - Sheet - FA2-03 - LEVEL 3 FIRE DETECTION AND NOTIFICATION SYSTEM
ORCA_150025_FIRE SUPRESSION - Sheet - FA2-B1 - BASEMENT LEVEL 1 FIRE DETECTION AND NOTIFICATION SYSTEM
ORCA_150025_FIRE SUPRESSION - Sheet - FA2-B2 - BASEMENT LEVEL 2 FIRE DETECTION AND NOTIFICATION SYSTEM
ORCA_150025_FIRE SUPRESSION - Sheet - FA2-B3 - BASEMENT LEVEL 3 FIRE DETECTION AND NOTIFICATION SYSTEM
ORCA_150025_FIRE SUPRESSION - Sheet - FS2-00 - FIRE PROTECTION DETAILS & NOTES
ORCA_150025_FIRE SUPRESSION - Sheet - FS2-B3 - BASEMENT LEVEL 3 FIRE SUPPRESSION
ORCA_150025_FIRE SUPRESSION - Sheet - FS2-B2 - BASEMENT LEVEL 2 FIRE SUPPRESSION
ORCA_150025_FIRE SUPRESSION - Sheet - FS2-B1 - BASEMENT LEVEL 1 FIRE SUPPRESSION
ORCA_150025_FIRE SUPRESSION - Sheet - FS2-01 - LEVEL 1 FIRE SUPPRESSION
ORCA_150025_FIRE SUPRESSION - Sheet - FS2-02 - LEVEL 2 FIRE SUPPRESSION
ORCA_150025_FIRE SUPRESSION - Sheet - FS2-03 - LEVEL 3 FIRE SUPPRESSION
ORCA_150025_FIRE SUPRESSION - Sheet - FS2-04 - ATTIC LEVEL FIRE SUPPRESSION
ORCA_150025_FIRE SUPRESSION - Sheet - FS2-05 - EXTERIOR ELEVATION - MIST FIRE SUPPRESSION