This document appears to be a solicitation for the construction of a new Emergency Department at the Stratton VA Medical Center in Albany, NY. The key details are:

The project involves complete demolition and construction of a new Emergency Department addition connected to the main hospital. Work includes site preparation, excavation, general construction, mechanical, plumbing, electrical, fire alarm, sprinkler, and medical gas systems. The successful contractor must provide a full-time OSHA certified superintendent dedicated to this project. Commissioning and punch list completion are required prior to project closeout. The contractor must utilize the VA's Autodesk Build construction management platform for project collaboration and communication. The period of performance is 550 calendar days from the Notice to Proceed. The solicitation number is 36C24224R0071.

View the file

Other files

File Type Posted
36C24224R0071 0008.docx DOCX document
36C24224R0071 0007.docx DOCX document
1-SE-701.pdf PDF
36C24224R0071 0006.docx DOCX document
SK-ES-802.1.pdf PDF
36C24224R0071 0005.docx DOCX document
Albany VA ED Walk Through Sign in List.pdf PDF
Albany VAMC Geotech Report for New ED.pdf PDF
087100 Door hardware SET 14.pdf PDF
071352 Modified Bituminous Sheet Waterproofing.pdf PDF
Stratton ED_103177_SET.pdf PDF
Q40 - 1-HA-100.pdf PDF
36C24224R0071 0004.docx DOCX document
055000 Metal Fabrications.pdf PDF
Subbasement Structural Originals.pdf PDF
084113 Aluminum Framed Entrances and Storefront8-18-22.pdf PDF
088000 Glazing-8-18-22.pdf PDF
36C24224R0071 0003.docx DOCX document
36C24224R0071 0002.docx DOCX document
19-181 100 Specs VA 528-809 Volume I.pdf PDF
19-181 100 Specs VA 528-809 Volume II.pdf PDF
EXHIBIT B - Sample Transmittal Letter for Past Performance Evaluation Questionnaire.docx DOCX document
36C24224R0071 0001.docx DOCX document
072400 EIFS.pdf PDF
EXHIBIT C - Past Performance Questionnaire.docx DOCX document
divisions 27-28 Specs.pdf PDF
1-22-24 - VA STRATTON NEW EMERGENCY DEPT SS_Part1.pdf PDF
2022-02-22 VA 528-809 Submittal Register-Divisions 01 - 34 FE.xlsx XLSX spreadsheet
Division 3 specs - concrete.pdf PDF
000115 List of Drawing Sheets.pdf PDF
Division 26 Specs - electrical.pdf PDF
Division 23 Specs - HVAC.pdf PDF
Division 7 Specs - Thermal and Moisture Protection.pdf PDF
1-22-24 - VA STRATTON NEW EMERGENCY DEPT SS_Part7.pdf PDF
Division 5 specs - Metals.pdf PDF
1-22-24 - VA STRATTON NEW EMERGENCY DEPT SS_Part8.pdf PDF
1-22-24 - VA STRATTON NEW EMERGENCY DEPT SS_Part2.pdf PDF
000110 TOC.pdf PDF
Division 9 specs - Finishes.pdf PDF
WD Albany NY20240002 07-12-2024.docx DOCX document
Division 6 Specs - wood and plastics.pdf PDF
Division 4 Specs - Masonry.pdf PDF
Division 2 specs - existing conditions.pdf PDF
Division 21-22 Specs.pdf PDF
1-22-24 - VA STRATTON NEW EMERGENCY DEPT SS_Part4.pdf PDF
Divisions 31-34 Specs.pdf PDF
Division 8 Spec - Doors and windows.pdf PDF
1-22-24 - VA STRATTON NEW EMERGENCY DEPT SS_Part5.pdf PDF
1-22-24 - VA STRATTON NEW EMERGENCY DEPT SS_Part11.pdf PDF
1-22-24 - VA STRATTON NEW EMERGENCY DEPT SS_Part9.pdf PDF
Show 40 more

Latest 50 of 56 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP8

8 12

4 14

DD

GG

M

L

J

151.8

N

3 6

Q

R

H.8

F

E E

H

P

11 13 17 182.4

K B40-8

MORGUE

B43-2

ELEVATOR

RM

B41

B42

B36-1

B36-2

B39

PUBLICATIONS

B39B40-1B40-2B40-3

MORGUE

B40-6

B40-7

B40-7

OFFICE

B43-3

ELEV.

VEST

B37-1B37-2

B43-4

MECH.

SW6

STAIR

B44

CANTEEN

B37

EMPLOYEE

GYM

C51-2 C51-1

ELEV

K.5

16.1 19 19.1

D.1 D.1

F.3

L.5

D.3 D.5

H.3 IT

E004

BIOMED

E005 PASSAGEWAY

B001

13.9

SW4

STAIR

SW15

STAIR

STORAGE

E001

2.5

OPEN STORAGE

E002

HYMAN

HAYES

ASSOCIATES

800 TROY-SCHENECTADY

ROAD, STE 103

LATHAM, NY 12110

(518) 452-3470 www.hymanhayes.com

ENGINEERING LLP

FE PROJECT NO: 19-181

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com

PROJECT

NORTH

KEY PLAN

CORE

WING 'C'

WING 'B' WING 'A'

WING 'D'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

6/

/2

:3 9:

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

528-809

Project Director

DECEMBER 16, 2022 JDFRevisions: Date:

STRATTON VA MEDICAL CENTER

NEW EMERGENCY DEPARTMENT100% FOR BID

SRB

FIRE PROTECTION: BASEMENT LEVEL SPRINKLER PLAN1

GENERAL NOTE:

KEYED NOTES:

AutoCAD SHX Text

EXISTING 6" SPRINKLER RISER

AutoCAD SHX Text

UP TO TEST DRAIN

AutoCAD SHX Text

UP TO STANDPIPE

AutoCAD SHX Text

NEW SPRINKLER SYSTEM TO SERVE BASEMENT. PROVIDE NEW TAMPER SWITCH & FLOW VALVES.

AutoCAD SHX Text

ORDINARY GROUP I HAZARD OCCUPANCY

AutoCAD SHX Text

INSTALL UPRIGHT UNDER STAIRS

AutoCAD SHX Text

NEW SUPPLY FOR DRY-TYPE SYSTEM SERVICE ON PLAN WEST END OF BASEMENT.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

ALBANY, NY

AutoCAD SHX Text

NY PROFESSIONAL ENGINEER NO. 069373-1 ISSUED 1992; EXP. 9/25

AutoCAD SHX Text E

AutoCAD SHX Text X

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text

FIRE PROTECTION: BASEMENT LEVEL SPRINKLER PLAN

AutoCAD SHX Text

1-FX-100

AutoCAD SHX Text

ORDINARY GROUP I

AutoCAD SHX Text 0.15

AutoCAD SHX Text

AutoCAD SHX Text

1. REMOVE ALL SPRINKLER MATERIALS AND LABOR PLAN WEST OF COLUMN LINE 9 FOR REMOVE ALL SPRINKLER MATERIALS AND LABOR PLAN WEST OF COLUMN LINE 9 FOR DEDUCT ALTERNATES 1 & 5. 2. ALL NEW SPRINKLER PIPING IN THE MECHANICAL AND ELECTRICAL ROOMS, MUST BE ALL NEW SPRINKLER PIPING IN THE MECHANICAL AND ELECTRICAL ROOMS, MUST BE PAINTED RED. 3. ALL NEW UPRIGHT PENDANT SPRINKLERS IN MECHANICAL AND ELECTRICAL SPACES MUST ALL NEW UPRIGHT PENDANT SPRINKLERS IN MECHANICAL AND ELECTRICAL SPACES MUST BE PROVIDED WITH GUARDS. 4. CONTRACTOR SHALL COORDINATE FINAL SPRINKLER HEAD LAYOUT WITH HVAC CONTRACTOR SHALL COORDINATE FINAL SPRINKLER HEAD LAYOUT WITH HVAC CONTRACTOR'S FINAL DUCTWORK LAYOUT IN MECHANICAL ROOMS. ADDITIONAL SPRINKLERS SHALL BE PROVIDED BELOW DUCTWORK TO ACCOMMODATE REQUIRED COVERAGE.

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE UPRIGHT SPRINKLER BELOW DUCTWORK. COORDINATE FINAL LOCATIONS WITH MECHANICAL CONTRACTOR. PROVIDE NEW UPRIGHT SPRINKLER HEAD AT CEILING HEIGHT OF NEW OPENING. UTILIZE EXISTING SPRINKLER PIPING SERVING TUNNEL. CONNECT SPRINKLER HEAD TO EXISTING SPRINKLER ZONE IN B-WING BASEMENT.

AutoCAD SHX Text

CONTRACTOR TO:

AutoCAD SHX Text

AutoCAD SHX Text

DN

8 12

4 14

D

GG

MM

L

J

151.81

N

3 6 10

Q

R

S

H.8

20 21

VESTIBULE

E100

TRIAGE

E104

E104A

PATIENT

TOILET

EXAM

E105

EXAM

E106

SANE EXAM

E107

E107A

TOILET/

SHWR

CORRIDOR

E126

EXAM

E108

CLEAN LINEN

E109

TOILET

E110

VESTIBULE

E111

EMS

E111A

CORRIDOR

E127

CORRIDOR

E132

E131

CLEAN

UTILITY

NURSE STATION

E130

RESUSCITATION

E112

E133

NURSE

STATION

MEDS

E134

ISO EXAM

E113

TOILET

E113A

E115

ANTE

ROOM/

DECON

WORK

DECON

E114

E116

BARIATRIC/

ISOLATION

ROOM

TOILET

E116A

TOILET

E117

EXAM

E118

EXAM

E119

EXAM -MH

E120

NOURISHMENT

E135A

EXAM

E121

EXAM

E122

EXAM

E123

EXAM

E124

EXAM

E125

C O

R R

ID

O

R E1

ST

R

ET

C

H

ER

E1

A E137

SOILED

HOLDING

CORRIDOR

E135

STORAGE

E147

E138

RESIDENT

WORK

E136

STAFF

TOILET

E140

BREAK/

KITCHEN

E141

STORAGE

E142

MAIL/

COPY

E143

OFFICE -

SHARED E144

OFFICE -

DIRECTOR

OFFICE - MD

E145

E145A

TOILET/

SHWR -

MD

STAIR

SW15

OFFICE

E149

CT

E151

TOILET

E147B

E152

CONTROL

ROOM

HAC

E150

STORAGE

E148

TOILET/ SHWR

E154A

LOCKER ROOM

E154

GRIEVING

E158

STORAGE

E159

VENDING

E103E103A

PUBLIC

TOILET

F

E

H

PP

11 13 17 182.4

CORRIDOR

E157

X-RAY

E153

RECEPTION

E101

CORRIDOR

E128

K

CORRIDOR

E155

E133B

CHARGE

NURSE

STATION

WAITING

E102A

CHECK-IN

E102

CORRIDOR

E156

E127A

STRETCHER

SW 6

STAIR

K.5

16.1 19 19.1

D.1

F.3 H.7

L.5

8.9

F.4

G.4

D.2

D.3 D.5

A

B

C

2.5

EXIT ACCESS

CORRIDOR

E146

HYMAN

HAYES

ASSOCIATES

800 TROY-SCHENECTADY

ROAD, STE 103

LATHAM, NY 12110

(518) 452-3470 www.hymanhayes.com

ENGINEERING LLP

FE PROJECT NO: 19-181

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com

PROJECT

NORTH

KEY PLAN

CORE

WING 'C'

WING 'B' WING 'A'

WING 'D'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

6/

/2

:3 9:

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

528-809

Project Director

DECEMBER 16, 2022 JDFRevisions: Date:

STRATTON VA MEDICAL CENTER

NEW EMERGENCY DEPARTMENT100% FOR BID

SRB

PROJECT

NORTH

KEY PLAN

CORE

WING 'C'

WING 'A'

WING 'D'

WING 'B'

FIRE PROTECTION: FIRST FLOOR SPRINKLER PLAN1

GENERAL NOTE:

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text S/S

AutoCAD SHX Text

SP

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text S/S

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text S/S

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

SP

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

ETR STANDPIPE, ROTATE EXISTING HOSE VALVE TO AVOID NEW DOOR OPENING.

AutoCAD SHX Text

EXISTING INSPECTORS TEST PORT AND FLOW SWITCH TO DRAIN

AutoCAD SHX Text

6" EXISTING SPRINKLER PIPE

AutoCAD SHX Text

TO TEST DRAIN

AutoCAD SHX Text NEW SPRINKLER SUPPLY PIPE TO WEST ZONE. PROVIDE NEW TAMPER SWITCH AND FLOW VALVES.

AutoCAD SHX Text

LIGHT HAZARD OCCUPANCY

AutoCAD SHX Text

NEW WEST SPRINKLER ZONE

AutoCAD SHX Text

SPRINKLER ZONE ADDED TO EXISTING MAIN LOBBY SMOKE COMPARTMENT

AutoCAD SHX Text M

AutoCAD SHX Text NEW 3" SUPPLY TO SMOKE COMPARTMENT ADDITION. VERIFY SIZE UPON COMPLETION OF HYDRAULIC CALCULATIONS.

AutoCAD SHX Text

EXISTING 4" LOBBY SPRINKLER MAIN

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

ALBANY, NY

AutoCAD SHX Text

NY PROFESSIONAL ENGINEER NO. 069373-1 ISSUED 1992; EXP. 9/25

AutoCAD SHX Text E

AutoCAD SHX Text X

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text

FIRE PROTECTION: FIRST FLOOR SPRINKLER PLAN

AutoCAD SHX Text

1-FX-101

AutoCAD SHX Text

CONTRACTOR TO:

1. ALL NEW SPRINKLER PIPING IN THE ALL NEW SPRINKLER PIPING IN THE MECHANICAL AND ELECTRICAL ROOMS, MUST BE PAINTED RED. 2. ALL NEW UPRIGHT PENDANT SPRINKLERS ALL NEW UPRIGHT PENDANT SPRINKLERS IN MECHANICAL AND ELECTRICAL SPACES MUST BE PROVIDED WITH GAURDS. 3. CONTRACTOR SHALL COORDINATE FINAL CONTRACTOR SHALL COORDINATE FINAL SPRINKLER HEAD LAYOUT WITH HVAC CONTRACTOR'S FINAL DUCTWORK LAYOUT IN MECHANICAL ROOMS. ADDITIONAL SPRINKLERS SHALL BE PROVIDED BELOW DUCTWORK TO ACCOMMODATE REQUIRED COVERAGE.

HYMAN

HAYES

ASSOCIATES

800 TROY-SCHENECTADY

ROAD, STE 103

LATHAM, NY 12110

(518) 452-3470 www.hymanhayes.com

ENGINEERING LLP

FE PROJECT NO: 19-181

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

6/

/2

:3 9:

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

528-809

Project Director

DECEMBER 16, 2022 JDFRevisions: Date:

STRATTON VA MEDICAL CENTER

NEW EMERGENCY DEPARTMENT100% FOR BID

SRB

COMMUNICATION SYMBOLS

GENERAL SYMBOLS

ELECTRICAL DEMOLITION NOTES:

LIGHTING SYMBOLS POWER SYMBOLS

ELECTRICAL LINE TYPES

GENERAL NOTES:

ABBREVIATIONS

WIRE AND CONDUIT SCHEDULE

FIRE ALARM NOTES:

PROPOSED NEW TRANSFORMER CUT-OVER SEQUENCE:

LEGEND AND SCHEDULE OF FIRE ALARM EQUIPMENT

LEGEND AND SCHEDULE OF NURSE CALL AND COMMUNICATIONS EQUIPMENT

LEGEND AND SCHEDULE OF ELECTRICAL EQUIPMENT

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

ALBANY, NY

AutoCAD SHX Text

NY PROFESSIONAL ENGINEER NO. 069373-1 ISSUED 1992; EXP. 9/25

AutoCAD SHX Text E

AutoCAD SHX Text X

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

ELECTRICAL: SYMBOLS, ABBREVIATIONS & NOTES

AutoCAD SHX Text

1-ES-001

AutoCAD SHX Text TV OUTLET. PROVIDE & INSTALL PULL STRING FROM OUTLET LOCATION TO IT ROOM 101 SF ABOVE CEILING EACH IN " 34" CONDUIT. MOUNT 18" AFF UNLESS OTHERWISE NOTED.

AutoCAD SHX Text

TV

AutoCAD SHX Text

POINT OF CONNECTION BETWEEN NEW AND EXISTING WORK

AutoCAD SHX Text

POINT OF DISCONNECT

AutoCAD SHX Text

INDICATES DRAWING NUMBER WHERE LOCATED

AutoCAD SHX Text

INDICATES SECTION LETTER

AutoCAD SHX Text X

AutoCAD SHX Text

XX

AutoCAD SHX Text

1. COORDINATE WITH ARCHITECTURAL PLANS FOR EXACT COORDINATE WITH ARCHITECTURAL PLANS FOR EXACT AREAS TO BE DEMOLISHED. 2. DISCONNECT AND REMOVE ALL DEVICES, FIXTURES, DISCONNECT AND REMOVE ALL DEVICES, FIXTURES, FIRE ALARM DEVICES, DATA/TEL. OUTLETS, POWER CONNECTIONS TO HVAC EQUIPMENT AND DISCONNECT SWITCHES, CONDUIT & WIRING FROM ALL WALLS/CEILINGS BEING REMOVED, WITHIN THIS AREA BACK TO POWER PANEL OF ORIGIN. ALL EXISTING CIRCUIT BREAKERS SHALL REMAIN IN PLACE AND LABELED AS "SPARE". 3. ALL EXISTING DEVICES SCHEDULED TO REMAIN SHALL ALL EXISTING DEVICES SCHEDULED TO REMAIN SHALL BE EXTENDED/RE-CIRCUITED TO MAINTAIN CONTINUITY OF CIRCUIT/DEVICES. 4. REMOVALS SHALL INCLUDE, BUT NOT BE LIMITED TO REMOVALS SHALL INCLUDE, BUT NOT BE LIMITED TO DEVICES, FIXTURES, FIRE ALARM DEVICES, DATA/TEL. OUTLETS, POWER CONNECTIONS TO HVAC EQUIPMENT AND DISCONNECT SWITCHES, CONDUIT & WIRING. 5. ELECTRICAL CONTRACTOR TO PROVIDE ALL NECESSARY ELECTRICAL CONTRACTOR TO PROVIDE ALL NECESSARY TEMPORARY WORK AND/OR MATERIALS TO RENDER EXISTING SYSTEM OPERATIONAL DURING ALL PHASES OF CONSTRUCTION IN ALL OCCUPIED SPACES. INCLUDING BUT NOT LIMITED TO, POWER, DATA, LIGHTING, EMERGENCY COMPONENTS & ALARMS. COORDINATE WITH ALL TRADES, OWNER AND OVERALL CONSTRUCTION PHASING SCHEDULE. 6. ALL CUTTING AND PATCHING NECESSARY FOR THE ALL CUTTING AND PATCHING NECESSARY FOR THE DEMOLITION WORK SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR. 7. IT SHALL BE THE OWNER'S RESPONSIBILITY TO IT SHALL BE THE OWNER'S RESPONSIBILITY TO REMOVE ANY LOOSE EQUIPMENT, FURNITURE, SUPPLIES, ETC. THAT MAY BE LOCATED IN THE AREA OF WORK. 8. THE PLANS ARE INTENDED TO CONVEY THE EXTENT THE PLANS ARE INTENDED TO CONVEY THE EXTENT AND SCOPE OF THE DEMOLITION WORK. EVERY ITEM INTENDED FOR REMOVAL MAY NOT BE SHOWN. THE CONTRACTOR IS ADVISED TO SURVEY THE PROJECT SITE BEFORE SUBMITTING A BID FOR DEMOLITION WORK.

AutoCAD SHX Text S

AutoCAD SHX Text J

AutoCAD SHX Text

PB

AutoCAD SHX Text SPEC GRADE NEMA 5-20R RECEPTACLE. -GFI INDICATES GROUND FAULT INTERRUPTION -WP INDICATES WEATHER PROOF ENCLOSURE -TP INDICATES TAMPER PROOF TYPE RECEPTACLE

AutoCAD SHX Text 2P, 3 WIRE, 250V GROUNDING NEMA 6-30R RECEPTACLE. -GFI INDICATES GROUND FAULT INTERRUPTION -WP INDICATES WEATHER PROOF ENCLOSURE

AutoCAD SHX Text

JUNCTION BOX, SIZE PER N.E.C.

AutoCAD SHX Text

EXIT LIGHT (SEE SCHEDULE)

AutoCAD SHX Text 3P, FUSED DISCONNECT SWITCH, FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. SHALL HAVE THE SAME # OF POLES & AMPERE RATING AS CONNECTING CIRCUIT UNLESS OTHERWISE NOTED.

AutoCAD SHX Text

PULL BOX, SIZED PER NEC

AutoCAD SHX Text CONDUIT HOME RUN TO DESIGNATED PANEL. REFER TO PANEL SCHEDULE FOR CONDUIT & CABLE QUANTITY AND SIZE.

AutoCAD SHX Text 120V, OR 208V, 1P, MOTOR STARTER WITH OVERLOADS TO SERVE AS DISCONNECTING MEANS. COORDINATE WITH OTHER TRADES.

AutoCAD SHX Text

CEILING MOUNTED VACANCY SENSOR

AutoCAD SHX Text 1P, 20A, TOGGLE SWITCH, PROVIDE WITH MATCHING FACE PLATE, COLOR BY ARCHITECT. MOUNT 48" AFF. '3' DENOTES WIRING FOR 3-WAY CAPABILITY. 'D' DENOTES WIRING FOR DIMMING CAPABILITY.

AutoCAD SHX Text SPEC GRADE NEMA 5-20R RECEPTACLE. MOUNT AT 44" AFF OR 9" ABOVE COUNTER, UON. -GFI INDICATES GROUND FAULT INTERRUPTION -WP INDICATES WEATHER PROOF ENCLOSURE -TP INDICATES TAMPER PROOF TYPE RECEPTACLE

AutoCAD SHX Text 1P, 3 WIRE, 125V QUAD RECEPTACLE. -GFI INDICATES GROUND FAULT INTERRUPTION -WP INDICATES WEATHER PROOF ENCLOSURE

AutoCAD SHX Text T

AutoCAD SHX Text

TRANSFORMER (SIZE SHOWN ON PLAN OR ONE-LINE DIAGRAM)

AutoCAD SHX Text

CIRCUIT BREAKER - 100A TRIP - SINGLE POLE

AutoCAD SHX Text 100A-1P

AutoCAD SHX Text

SPECIAL PURPOSE CONNECTION.

AutoCAD SHX Text S

AutoCAD SHX Text

GROUND

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

DOUBLE HOME RUN

AutoCAD SHX Text

TRIPLE HOME RUN

AutoCAD SHX Text 1P, 20A, TOGGLE SWITCH WITH BUILT-IN VACANCY SENSOR, PROVIDE WITH MATCHING FACE PLATE, COLOR BY ARCHITECT. MOUNT 48" AFF. '3' DENOTES WIRING FOR 3-WAY CAPABILITY. 'D' DENOTES WIRING FOR DIMMING CAPABILITY.

AutoCAD SHX Text

EXISTING TO BE REMOVED

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text

NEW DEVICE

AutoCAD SHX Text

NEW WIRING

AutoCAD SHX Text

NEW FIXTURE

AutoCAD SHX Text or

AutoCAD SHX Text TELEPHONE OUTLET. PROVIDE & INSTALL CAT6A CABLE FROM OUTLET LOCATION TO IT ROOM 101 SF ABOVE CEILING IN 34" CONDUIT. MOUNT OUTLET 18" AFF UNLESS OTHERWISE NOTED.

AutoCAD SHX Text COMBINATION TELEPHONE/DATA OUTLET. PROVIDE & INSTALL (4) CAT6A CABLES FROM OUTLET LOCATION IT ROOM 101 SF ABOVE CEILING EACH IN " CONDUIT. MOUNT 18" AFF 34" CONDUIT. MOUNT 18" AFF UNLESS OTHERWISE NOTED.

AutoCAD SHX Text DATA OUTLET. PROVIDE & INSTALL PROVIDE (4) CAT6A CABLE FROM OUTLET LOCATION TO IT ROOM 101 SF ABOVE CEILING EACH IN " CONDUIT. MOUNT 18" AFF UNLESS 34" CONDUIT. MOUNT 18" AFF UNLESS OTHERWISE NOTED.

AutoCAD SHX Text S

AutoCAD SHX Text m

AutoCAD SHX Text

1. ALL CONDUITS ARE SHOWN DIAGRAMMATICALLY, EXACT RUNS SHALL BE ALL CONDUITS ARE SHOWN DIAGRAMMATICALLY, EXACT RUNS SHALL BE DETERMINED IN FIELD EXCEPT WHERE SPECIFICALLY DIMENSIONED ON CONDUIT LAYOUTS. CONTRACTOR SHALL FOLLOW MINIMUM SPACING REQUIREMENTS TO REDUCE ELECTROMAGNETIC INTERFERENCE. COORDINATE CONDUIT ROUTING WITH ALL OTHER TRADES. 2. ALL EXPOSED CONDUIT SHALL BE RUN PARALLEL TO BUILDING WALLS AND ALL EXPOSED CONDUIT SHALL BE RUN PARALLEL TO BUILDING WALLS AND BEAMS EXCEPT WHERE OTHERWISE SHOWN. CONTRACTOR SHALL INSTALL CONDUIT IN SUCH A MANNER TO AVOID ALL INTERFERENCES. 3. DEFLECTION/EXPANSION FITTINGS SHALL BE PROVIDED WHERE RIGID METAL DEFLECTION/EXPANSION FITTINGS SHALL BE PROVIDED WHERE RIGID METAL CONDUIT CROSSES STRUCTURAL EXPANSION JOINTS. 4. EXPOSED CONDUIT SHALL BE SUPPORTED ON WALLS OR CEILINGS BY EXPOSED CONDUIT SHALL BE SUPPORTED ON WALLS OR CEILINGS BY APPROVED HANGERS OF ANGLE OR CHANNEL CONSTRUCTION. CONDUITS SHALL BE SUPPORTED AT LEAST EVERY EIGHT (8) FEET. 5. ALL SPARE CONDUITS SHALL BE TERMINATED AS SHOWN ON CONDUIT ALL SPARE CONDUITS SHALL BE TERMINATED AS SHOWN ON CONDUIT LAYOUTS AND SHALL BE CAPPED 3" ABOVE FINISHED FLOOR. 6. NO CONDUIT SHALL BE SMALLER THAN " UNLESS NOTED OTHERWISE ON NO CONDUIT SHALL BE SMALLER THAN " UNLESS NOTED OTHERWISE ON 34" UNLESS NOTED OTHERWISE ON PLANS. 7. EXACT CONDUIT STUB-UP LOCATIONS ARE TO BE DETERMINED BY THE EXACT CONDUIT STUB-UP LOCATIONS ARE TO BE DETERMINED BY THE ELECTRICAL CONTRACTOR BASED ON CERTIFIED MANUFACTURER'S DRAWINGS OF THE RESPECTIVE EQUIPMENT. CONDUIT SHALL BE INSTALLED TO AGREE WITH EQUIPMENT FURNISHED. 8. ALL LIGHTING WIRING SHALL BE #12AWG. UNLESS OTHERWISE NOTED. THE ALL LIGHTING WIRING SHALL BE #12AWG. UNLESS OTHERWISE NOTED. THE NUMBER OF WIRES SHOWN ON THE DRAWINGS IS NOT NECESSARILY THE CORRECT NUMBER REQUIRED. THE CONTRACTOR SHALL INSTALL AS MANY AS ARE NECESSARY FOR PROVIDING A COMPLETE ELECTRICAL SYSTEM IN EACH CASE. 9. CONDUITS PASSING THROUGH BUILDING FLOORS OR WALLS BELOW GRADE CONDUITS PASSING THROUGH BUILDING FLOORS OR WALLS BELOW GRADE ARE TO BE INSTALLED WITH WATERTIGHT THRU WALL CONDUIT SEAL FITTINGS. 10. EQUIPMENT FURNISHED BY OTHERS SHALL BE INSTALLED & ENERGIZED BY EQUIPMENT FURNISHED BY OTHERS SHALL BE INSTALLED & ENERGIZED BY THE ELECTRICAL CONTRACTOR. 11. ONLY CONDUITS HAVING OUTSIDE DIAMETERS NO LARGER THAN ONE-THIRD ONLY CONDUITS HAVING OUTSIDE DIAMETERS NO LARGER THAN ONE-THIRD OF THE THICKNESS OF SLAB MAY BE INSTALLED WITHIN THE CONCRETE SLABS. 12. CONDUITS IN STRUCTURAL SLABS ARE TO BE SPACED SO AS TO PROVIDE CONDUITS IN STRUCTURAL SLABS ARE TO BE SPACED SO AS TO PROVIDE NO LESS THAN THREE CONDUIT DIAMETERS, CENTER TO CENTER, WHEREVER POSSIBLE. LARGER SPACING IS PREFERRED. 13. CONTINUOUS ROWS OF CONDUITS ARE NOT TO BE PLACED IMMEDIATELY CONTINUOUS ROWS OF CONDUITS ARE NOT TO BE PLACED IMMEDIATELY ALONG BEARING ENDS OF SLABS. 14. THE ELECTRICAL CONTRACTOR SHALL NOT ENDANGER THE STABILITY OF THE THE ELECTRICAL CONTRACTOR SHALL NOT ENDANGER THE STABILITY OF THE STRUCTURE OR ANY PART THEREOF BY CUTTING, DRILLING OR OTHERWISE, AND SHALL NOT IN ANY WAY CUT OR ALTER THE WORK OF ANY OTHER CONTRACTOR, EXCEPT WITH THE WRITTEN CONSENT OF AND UNDER THE DIRECTION OF THE ARCHITECT AND/OR GENERAL CONTRACTOR. 15. THE ELECTRICAL CONTRACTOR SHALL SECURE ALL APPROVALS AND THE ELECTRICAL CONTRACTOR SHALL SECURE ALL APPROVALS AND CERTIFICATES AND PAY ALL FEES FOR ALL THE WORK INSTALLED. CERTIFICATES SHALL BE DELIVERED TO THE GENERAL CONTRACTOR BEFORE FINAL PAYMENT WILL BE MADE. 16. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST APPLICABLE ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST APPLICABLE VERSION OF THE NEC AS WELL AS ALL STATE AND LOCAL CODES. 17. THE DRAWINGS INDICATE AND THE SPECIFICATIONS DESCRIBE THE GENERAL THE DRAWINGS INDICATE AND THE SPECIFICATIONS DESCRIBE THE GENERAL ARRANGEMENTS AND LOCATION OF OUTLET BOXES, ETC. THE CONTRACTOR SHALL, WITHOUT EXTRA COST TO THE OWNER, MAKE ALL REASONABLE MODIFICATIONS IN THE WORK AS MAY BE REQUIRED TO PREVENT CONFLICT WITH EXISTING CONDITIONS, THE WORK OF OTHER TRADES AND FOR THE PROPER INSTALLATION OF THE WORK. 18. PRIOR TO SUBMISSION OF BID PROPOSAL, THE CONTRACTOR SHALL VISIT PRIOR TO SUBMISSION OF BID PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE CAREFULLY THE EXISTING CONDITIONS AND THE DIFFICULTIES THAT WILL BE INCURRED DURING THE PERFORMANCE OF HIS WORK. A. VERIFY & COORDINATE CONDUIT ROUTING. VERIFY & COORDINATE CONDUIT ROUTING. B. VERIFY & COORDINATE SCOPE OF DEMOLITION WORK. VERIFY & COORDINATE SCOPE OF DEMOLITION WORK. C. VERIFY & COORDINATE SCOPE OF WORK INVOLVING CONNECTIONS TO VERIFY & COORDINATE SCOPE OF WORK INVOLVING CONNECTIONS TO EXISTING BASE BUILDING SYSTEMS. D. VERIFY SCOPE OF WORK THAT HAS TO BE DONE WITH EXISTING FIRE VERIFY SCOPE OF WORK THAT HAS TO BE DONE WITH EXISTING FIRE ALARM SYSTEM AS REQUIRED TO ACCOMMODATE ALL ADDED DEVICES. E. VERIFY WITH GENERAL CONTRACTOR SCOPE OF WORK ASSOCIATED VERIFY WITH GENERAL CONTRACTOR SCOPE OF WORK ASSOCIATED WITH RIGGING OF EQUIPMENT TO BE PREPURCHASED. F. COORDINATE WITH THE BUILDING ENGINEER AND GENERAL CONTRACTOR COORDINATE WITH THE BUILDING ENGINEER AND GENERAL CONTRACTOR SHUT DOWNS OF EXISTING FACILITIES. 19. ARRANGE FOR SITE VISIT WITH THE BLDG. OWNER REPRESENTATIVE AND ARRANGE FOR SITE VISIT WITH THE BLDG. OWNER REPRESENTATIVE AND GENERAL CONTRACTOR. 20. CLAIMS FOR ADDITIONAL COMPENSATION ARISING DUE TO THE FAILURE OF CLAIMS FOR ADDITIONAL COMPENSATION ARISING DUE TO THE FAILURE OF THE CONTRACTOR TO FULLY UNDERSTAND THE SITE CONDITIONS SHALL NOT BE PAID FOR BY ANY OTHER PARTY. 21. CONNECTIONS TO EXISTING WORK: CONNECTIONS TO EXISTING WORK: A. INSTALL NEW WORK AND CONNECT TO EXISTING WORK WITH MINIMUM INSTALL NEW WORK AND CONNECT TO EXISTING WORK WITH MINIMUM INTERFERENCE TO EXISTING FACILITIES. B. TEMPORARY SHUTDOWNS OF EXISTING SERVICES: TEMPORARY SHUTDOWNS OF EXISTING SERVICES: a. AT NO ADDITIONAL CHARGES. AT NO ADDITIONAL CHARGES. b. AT TIMES NOT TO INTERFERE WITH NORMAL OPERATION OF AT TIMES NOT TO INTERFERE WITH NORMAL OPERATION OF EXISTING SERVICES. c. ONLY WITH WRITTEN CONSENT OF THE GENERAL CONTRACTOR ONLY WITH WRITTEN CONSENT OF THE GENERAL CONTRACTOR AND/OR BUILDING OWNERS REPRESENTATIVE. C. ALARM AND EMERGENCY SYSTEMS: NOT TO BE INTERRUPTED. ALARM AND EMERGENCY SYSTEMS: NOT TO BE INTERRUPTED. D. MAINTAIN CONTINUOUS OPERATION OF EXISTING FACILITIES AS MAINTAIN CONTINUOUS OPERATION OF EXISTING FACILITIES AS REQUIRED WITH NECESSARY TEMPORARY CONNECTIONS BETWEEN NEW AND EXISTING WORK. E. CONNECT NEW WORK TO EXISTING WORK IN NEAT AND ACCEPTABLE CONNECT NEW WORK TO EXISTING WORK IN NEAT AND ACCEPTABLE MANNER. RESTORE EXISTING DISTURBED WORK TO ORIGINAL CONDITION, INCLUDING MAINTENANCE OF WIRING CONTINUITY AS REQUIRED. F. PRIOR TO DEMOLITION OF AN EXISTING POWER PANEL, THE PRIOR TO DEMOLITION OF AN EXISTING POWER PANEL, THE CONTRACTOR SHALL SEARCH OUT ALL EXISTING CIRCUITS FED FROM THE PANEL TO PREVENT ANY ACCIDENTAL SERVICE INTERRUPTIONS. 22. LEAVE WIRE SUFFICIENTLY LONG TO PERMIT MAKING FINAL CONNECTIONS. LEAVE WIRE SUFFICIENTLY LONG TO PERMIT MAKING FINAL CONNECTIONS. CONDUIT OVER 10 FEET IN WHICH WIRING IS NOT INSTALLED-FURNISH PULL STRING. 23. DO NOT PULL THERMOPLASTIC WIRES AT TEMPERATURES LOWER THAN 32 DO NOT PULL THERMOPLASTIC WIRES AT TEMPERATURES LOWER THAN 32 DEG F (0 DEG C). PROVIDE CABLE SUPPORTS FOR WIRE IN RISER CONDUITS AS REQUIRED BY CODE. 24. LOCATIONS INDICATED FOR LOCAL WALL SWITCHES ARE SUBJECT TO LOCATIONS INDICATED FOR LOCAL WALL SWITCHES ARE SUBJECT TO MODIFICATIONS AT OR NEAR DOORS. INSTALL SWITCH ON SIDE OPPOSITE HINGE; VERIFY FINAL DOOR HINGE LOCATION IN FIELD PRIOR TO SWITCH OUTLET INSTALLATION. 25. JUNCTION & PULL BOXES: DO NOT LOCATE EXPOSED IN FINISH SPACES JUNCTION & PULL BOXES: DO NOT LOCATE EXPOSED IN FINISH SPACES UNLESS REQUIRED BY NEC. WHERE NECESSARY, REROUTE CONDUIT OR MAKE OTHER ARRANGEMENTS FOR CONCEALMENT. PROVIDE PULL BOXES AS INDICATED AND WHEREVER NECESSARY TO FACILITATE PULLING OF WIRE AND COORDINATE LOCATIONS WITH OTHER TRADES. COVERS OF JUNCTION AND PULL BOXES SHALL BE ACCESSIBLE. FOR EMPTY CONDUITS, INSTALL PULL BOXES EVERY 100 FEET AND AS INDICATED. COORDINATE LOCATIONS WITH OTHER TRADES. 26. SUPPORT PANEL, JUNCTION & PULL BOXES INDEPENDENTLY TO BUILDING SUPPORT PANEL, JUNCTION & PULL BOXES INDEPENDENTLY TO BUILDING STRUCTURE WITH NO WEIGHT BEARING ON CONDUIT. 27. ALL ACCESS DOOR LOCATIONS SHALL BE REVIEWED BY ARCHITECT PRIOR TO ALL ACCESS DOOR LOCATIONS SHALL BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. 28. FOR EACH LOCATION OF OTHER TRADES EQUIPMENT, SEE RESPECTIVE TRADE FOR EACH LOCATION OF OTHER TRADES EQUIPMENT, SEE RESPECTIVE TRADE DRAWINGS. 29. FOR RECEPTACLE & OUTLETS MOUNTING HEIGHTS AND POSITION FOR RECEPTACLE & OUTLETS MOUNTING HEIGHTS AND POSITION (HORIZONTAL, VERTICAL), COORDINATE WITH ARCHITECT, OWNER, REPRESENTATIVE & DATA/ COMMUNICATION CONSULTANT. 30. CONTRACTOR SHALL PROVIDE AND INSTALL ALL COMPONENTS INDICATED ON CONTRACTOR SHALL PROVIDE AND INSTALL ALL COMPONENTS INDICATED ON DETAILS SHEETS, PLANS, SPECIFICATIONS AND ALL PERTINENT EQUIPMENT REQUIRED FOR A COMPLETE WORKABLE SYSTEM. 31. ALL CONDUITS, TRANSFORMERS ETC. SHALL BE SUPPORTED FROM ALL CONDUITS, TRANSFORMERS ETC. SHALL BE SUPPORTED FROM STRUCTURAL STEEL ONLY. COORDINATE WITH GENERAL CONTRACTOR. 32. ALL FLOOR MOUNTED ELECTRICAL EQUIPMENT IN ELECTRICAL AND SERVICE ALL FLOOR MOUNTED ELECTRICAL EQUIPMENT IN ELECTRICAL AND SERVICE SWITCHBOARD ROOM SHALL BE INSTALLED ON 4" CONCRETE PAD AS REQUIRED TO SUPPORT EACH SECTION OF EQUIPMENT. COORDINATE WITH GENERAL CONTRACTOR. 33. PROVIDE BARRIERS IN ALL PULL BOXES FOR CONDUIT SETS. PROVIDE BARRIERS IN ALL PULL BOXES FOR CONDUIT SETS. 34. PAINT AND RUST PROOF ALL HARDWARE & CONDUITS ON ROOF AND IN PAINT AND RUST PROOF ALL HARDWARE & CONDUITS ON ROOF AND IN EXPOSED AREAS AS DIRECTED BY GENERAL CONTRACTOR. 35. NUMBER SHOWN ADJACENT TO LIGHTING FIXTURES, RECEPTACLES, OUTLETS, NUMBER SHOWN ADJACENT TO LIGHTING FIXTURES, RECEPTACLES, OUTLETS, JUNCTION BOXES ETC. INDICATES CIRCUIT NUMBER. 36. ALL GROUND CONNECTIONS TO THE BUILDING STEEL SHALL BE EXOTHERMIC ALL GROUND CONNECTIONS TO THE BUILDING STEEL SHALL BE EXOTHERMIC WELDED. 37. FLEXIBLE CONNECTIONS IN EXPOSED AREAS SHALL NOT EXCEED 18" FLEXIBLE CONNECTIONS IN EXPOSED AREAS SHALL NOT EXCEED 18" MAXIMUM. 38. ALL EQUIPMENT DEVICES, WIRING, ETC. SHOWN ON THE DRAWINGS IS NEW ALL EQUIPMENT DEVICES, WIRING, ETC. SHOWN ON THE DRAWINGS IS NEW UNLESS OTHERWISE NOTED. 39. ELECTRICAL CONTRACTOR SHALL PROVIDE SLEEVES/ OPENINGS FOR ALL ELECTRICAL CONTRACTOR SHALL PROVIDE SLEEVES/ OPENINGS FOR ALL CONDUIT RISERS PENETRATING WALLS, ROOF & FLOOR SLABS. ALL ROOF AND MECH. ROOMS SLAB PENETRATIONS SHALL BE WATERPROOF. METHOD OF PENETRATIONS & FIRE/WATER WATER PROOFING SHALL BE APPROVED BY ARCHITECT AND STRUCTURAL ENGINEER, COORDINATE WITH GENERAL CONTRACTOR. 40. ELECTRICAL CONTRACTOR SHALL BECOME FAMILIAR AND COMPLY WITH ELECTRICAL CONTRACTOR SHALL BECOME FAMILIAR AND COMPLY WITH OWNERS BUILDING STANDARDS FOR CONSTRUCTION. 41. ALL FINAL CONNECTIONS TO VIBRATING EQUIPMENT (MOTORS, GENERATORS ALL FINAL CONNECTIONS TO VIBRATING EQUIPMENT (MOTORS, GENERATORS ETC.) SHALL BE THROUGH A LIQUID TIGHT FLEXIBLE METAL CONDUIT. 42. LOCATION OF ALL SLAB PENETRATIONS FOR SLEEVES & CONDUITS SHALL BE LOCATION OF ALL SLAB PENETRATIONS FOR SLEEVES & CONDUITS SHALL BE REVIEWED & APPROVED BY STRUCTURAL ENGINEER & ARCHITECT. 43. CONTRACTOR SHALL WIRE NO MORE THAN SIX CONVENIENCE RECEPTACLES CONTRACTOR SHALL WIRE NO MORE THAN SIX CONVENIENCE RECEPTACLES TO A 20A SINGLE POLE CIRCUIT. UTILIZE 2-#12&1 #12 GND IN " 34" CONDUIT & 1-20A SINGLE POLE CIRCUIT BREAKER FOR EACH CIRCUIT. INSTALL ADDITIONAL CIRCUIT AS NECESSARY TO MEET THIS REQUIREMENT. 44. ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS SHALL BE SEALED ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS SHALL BE SEALED FIRE AND SMOKE TIGHT WITH AN APPROPRIATE U.L. LISTED FIRESTOPPING MATERIAL AND OR SYSTEM. 45. ALL WIRING IN PATIENT CARE AREAS SHALL BE PROVIDED WITH AN ALL WIRING IN PATIENT CARE AREAS SHALL BE PROVIDED WITH AN INSULATED COPPER EQUIPMENT GROUNDING CONDUCTOR AND SHALL BE INSTALLED IN A METALLIC RACEWAY SYSTEM LISTED AS AN EQUIPMENT GROUNDING CONDUCTOR. 46. THE TERMS "PROVIDE" OR "FURNISH", AS USED ON THESE PLANS, INDICATE THE TERMS "PROVIDE" OR "FURNISH", AS USED ON THESE PLANS, INDICATE THAT THE CONTRACTOR IS TO FURNISH AND INSTALL THE REFERENCED EQUIPMENT OR SYSTEMS IN THEIR ENTIRETY AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. 47. CONTRACT CLOSE OUT: IN THE PRESENCE OF THE OWNER, ENGINEER OR CONTRACT CLOSE OUT: IN THE PRESENCE OF THE OWNER, ENGINEER OR ARCHITECT; DEMONSTRATING OPERATION OF SYSTEMS AND THAT ALL SPECIFICATIONS HAVE BEEN MET TO THE SATISFACTION OF ALL PARTIES. 48. IT IS THE INTENT OF THESE PLANS AND SPECIFICATIONS TO PROVIDE IT IS THE INTENT OF THESE PLANS AND SPECIFICATIONS TO PROVIDE ALTERATIONS AND/OR NEW CONSTRUCTION AS INDICATED ON THE DRAWINGS AND IN THE SPECIFICATIONS TO PROVIDE COMPLETE NEW SYSTEMS IN EVERY RESPECT, CAPABLE OF OPERATING AS DESIGNED. IT IS NOT INTENDED THAT EVERY FITTING, MINOR DETAIL OR FEATURE BE SHOWN ON DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DETAIL NECESSARY FOR COMPLETION OF THESE SYSTEMS IN ACCORDANCE WITH GOOD PRACTICE.

AutoCAD SHX Text

CB

AutoCAD SHX Text

AFF

AutoCAD SHX Text

JB

AutoCAD SHX Text

LP

AutoCAD SHX Text

DP

AutoCAD SHX Text

XFMR/

AutoCAD SHX Text

BCW

AutoCAD SHX Text

VFC

AutoCAD SHX Text

AF

AutoCAD SHX Text

FT

AutoCAD SHX Text W

AutoCAD SHX Text

CIRCUIT BREAKER

AutoCAD SHX Text

ABOVE FINISHED FLOOR

AutoCAD SHX Text

JUNCTION BOX

AutoCAD SHX Text

LIGHTING PANEL

AutoCAD SHX Text

DISTRIBUTION PANEL

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

BARE COPPER WIRE

AutoCAD SHX Text

VARIABLE FREQUENCY CONTROLLER

AutoCAD SHX Text

ALUMINUM

AutoCAD SHX Text

FEET OR FOOT

AutoCAD SHX Text

WATT

AutoCAD SHX Text F.W.E.

AutoCAD SHX Text

FURNISHED WITH EQUIPMENT

AutoCAD SHX Text

CKT

AutoCAD SHX Text

CIRCUIT

AutoCAD SHX Text

CLG

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

FIRE ALARM PANEL

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

FL

AutoCAD SHX Text

FAP

AutoCAD SHX Text

FLEX

AutoCAD SHX Text

FLEXIBLE

AutoCAD SHX Text A

AutoCAD SHX Text

AD

AutoCAD SHX Text

AMPERE

AutoCAD SHX Text

AUTOMATIC DAMPER

AutoCAD SHX Text

ATS

AutoCAD SHX Text

AIC

AutoCAD SHX Text

AUTOMATIC TRANSFER SWITCH

AutoCAD SHX Text

AMPERE INTERRUPTING CAPACITY

AutoCAD SHX Text

AUTO

AutoCAD SHX Text

AUTOMATIC

AutoCAD SHX Text

AWG

AutoCAD SHX Text

AMERICAN WIRE GAUGE

AutoCAD SHX Text

AL

AutoCAD SHX Text

AMPERE FRAME

AutoCAD SHX Text

CAT

AutoCAD SHX Text

CATALOG

AutoCAD SHX Text C

AutoCAD SHX Text

CONDUIT

AutoCAD SHX Text

CU

AutoCAD SHX Text

COPPER

AutoCAD SHX Text

DISCONNECT (LOCKOUT) SWITCH

AutoCAD SHX Text

DRAWING

AutoCAD SHX Text

DWG

AutoCAD SHX Text

DS

AutoCAD SHX Text

FA

AutoCAD SHX Text

FIRE ALARM

AutoCAD SHX Text

DIVISION

AutoCAD SHX Text

DIV

AutoCAD SHX Text E.P.O.

AutoCAD SHX Text

EMERGENCY POWER OFF

AutoCAD SHX Text

EQUIP.

AutoCAD SHX Text

EQUIPMENT

AutoCAD SHX Text

EMT

AutoCAD SHX Text

ELECTRICAL METALLIC TUBING

AutoCAD SHX Text

ELECTRICAL CONTRACTOR

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text E.C.

AutoCAD SHX Text

ELEV

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

EA

AutoCAD SHX Text

EACH

AutoCAD SHX Text

G, GND

AutoCAD SHX Text

GROUND

AutoCAD SHX Text

GEN.

AutoCAD SHX Text

GENERATOR

AutoCAD SHX Text

GFI

AutoCAD SHX Text

GROUND FAULT INTERRUPTER

AutoCAD SHX Text G.C.

AutoCAD SHX Text

GENERAL CONTRACTOR

AutoCAD SHX Text

HP

AutoCAD SHX Text

HORSEPOWER

AutoCAD SHX Text

HVAC

AutoCAD SHX Text

HEATING, VENTILATING & AIR CONDITIONING

AutoCAD SHX Text

KV

AutoCAD SHX Text

KILO VOLT

AutoCAD SHX Text

KVA

AutoCAD SHX Text

KILO VOLT AMP

AutoCAD SHX Text

HZ

AutoCAD SHX Text

HERTZ

AutoCAD SHX Text

KW

AutoCAD SHX Text

KILO WATT

AutoCAD SHX Text

IC

AutoCAD SHX Text

INTERRUPTING CAPACITY

AutoCAD SHX Text

IMC

AutoCAD SHX Text

INTERMEDIATE METAL CONDUIT

AutoCAD SHX Text

LTG

AutoCAD SHX Text

LIGHTING

AutoCAD SHX Text

MECH

AutoCAD SHX Text

MTG

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

MOUNTING

AutoCAD SHX Text

MDP

AutoCAD SHX Text

MAIN DISTRIBUTION PANEL

AutoCAD SHX Text

MTD

AutoCAD SHX Text

MOUNTED

AutoCAD SHX Text

MLO

AutoCAD SHX Text

MAIN LUGS ONLY

AutoCAD SHX Text

MCM

AutoCAD SHX Text

THOUSAND CIRCULAR MILS

AutoCAD SHX Text M.C.

AutoCAD SHX Text

MECHANICAL CONTRACTOR

AutoCAD SHX Text

MCB

AutoCAD SHX Text

MAIN CIRCUIT BREAKER

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text N

AutoCAD SHX Text

NEUTRAL

AutoCAD SHX Text

NEC

AutoCAD SHX Text

NATIONAL ELECTRIC CODE

AutoCAD SHX Text

NIC

AutoCAD SHX Text

NOT IN CONTRACT

AutoCAD SHX Text

NM

AutoCAD SHX Text

NON-METALLIC CONDUIT

AutoCAD SHX Text P

AutoCAD SHX Text

POLE

AutoCAD SHX Text

PB

AutoCAD SHX Text

PULL BOX

AutoCAD SHX Text %%C

AutoCAD SHX Text

PHASE

AutoCAD SHX Text

PWR

AutoCAD SHX Text

POWER

AutoCAD SHX Text

RECEPT.

AutoCAD SHX Text

RECEPTACLE

AutoCAD SHX Text

REQ.

AutoCAD SHX Text

REQUIRED

AutoCAD SHX Text

RGS

AutoCAD SHX Text

RIGID GALVANIZED STEEL

AutoCAD SHX Text

RM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

SCHED.

AutoCAD SHX Text

SCHEDULE

AutoCAD SHX Text

SECT.

AutoCAD SHX Text

SECTION

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text

SPECIFICATION

AutoCAD SHX Text

SPKR.

AutoCAD SHX Text

SPEAKER

AutoCAD SHX Text

SW

AutoCAD SHX Text

SWITCH

AutoCAD SHX Text

SWBD

AutoCAD SHX Text

SWITCH BOARD

AutoCAD SHX Text

SYS

AutoCAD SHX Text

SYSTEM

AutoCAD SHX Text

TEL

AutoCAD SHX Text

TELEPHONE

AutoCAD SHX Text

TC

AutoCAD SHX Text

TIME CLOCK

AutoCAD SHX Text

TYP

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

TRANSF.

AutoCAD SHX Text

VERIFY IN FIELD

AutoCAD SHX Text

VIF

AutoCAD SHX Text

ACT

AutoCAD SHX Text

ACOUSTIC CEILING TILE

AutoCAD SHX Text U.N.O.

AutoCAD SHX Text

UNLESS NOTED OTHERWISE

AutoCAD SHX Text

LED

AutoCAD SHX Text

LIGHT-EMITTING DIODE

AutoCAD SHX Text PROXIMITY CARD READER. PROVIDE AND INSTALL (1) CAT6 CABLE BACK FROM LOCATION TO TIPS CLOSET ABOVE CEILING IN " 34" CONDUIT. PROVIDE READER AND ALL APPURTENANCES IN COORDINATION WITH VA ACCESS CONTROL VENDOR. PROGRAMMING BY ACCESS CONTROL VENDOR. CARD READERS MUST BE DISABLED UPON ACTIVATION OF FIRE ALARM. PROVIDE JUNCTION BOX IN CEILING AND CIRCUIT BACK TO ED-LS/18.

AutoCAD SHX Text FIXED CAMERA. RETAIN THE SERVICES OF THE FACILITY'S SECURITY CAMERA VENDOR AND CONNECT TO EXISTING POLICE SECURITY SYSTEM. ARROW DENOTES DIRECTION CAMERA FACES. # DENOTES NUMBER OF CAMERAS. 'E' DENOTES CAMERA IS EXTERIOR.

AutoCAD SHX Text (#/E)

AutoCAD SHX Text C

AutoCAD SHX Text

CR

AutoCAD SHX Text

TAG

AutoCAD SHX Text D

AutoCAD SHX Text 225A

AutoCAD SHX Text

OVER CURRENT PROTECTION

AutoCAD SHX Text

FEEDER SIZE: WIRE AND CONDUIT

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text 400A

AutoCAD SHX Text 2500A

AutoCAD SHX Text

(4) 500 MCM, (1) #3 GND. (1) 4" CONDUIT

AutoCAD SHX Text EXISTING CONDUCTORS FEEDING SWBD B 6 SETS: (4) 600 MCM, (1) 400 MCM GND. (1) 4" CONDUIT

AutoCAD SHX Text E

AutoCAD SHX Text 100A

AutoCAD SHX Text

(4) #2, (1) #8 GND, (1) 1 1/2" CONDUIT

AutoCAD SHX Text

(4) 4/0 (1) #4 GND, (1) 2 1/2" CONDUIT

AutoCAD SHX Text P

AutoCAD SHX Text

13.2KV

AutoCAD SHX Text

(3) 2/0, 15KV XLPE (1) #2 600V GND, (1) 4" CONDUIT

AutoCAD SHX Text

1. REFER TO THE FLOOR PLANS FOR LOCATION & REFER TO THE FLOOR PLANS FOR LOCATION & QUANTITY OF FIRE ALARM DEVICES. 2. ALL FIRE ALARM WIRING SHALL BE IN RED CONDUIT ALL FIRE ALARM WIRING SHALL BE IN RED CONDUIT AND SHALL BE CONCEALED IN CEILING SPACES & WALLS. 3. SYSTEM SCHEMATIC IS A DIAGRAMMATIC SYSTEM SCHEMATIC IS A DIAGRAMMATIC REPRESENTATION OF THE FIRE ALARM SYSTEM. THE SYSTEM SHALL BE INSTALLED AND WIRED AS PER THE SYSTEM MANUFACTURER'S RECOMMENDATION FOR A COMPLETE AND OPERABLE SYSTEM. 4. CONTRACTOR IS RESPONSIBLE FOR ALL FILING AND CONTRACTOR IS RESPONSIBLE FOR ALL FILING AND FINAL INSPECTION AS PER THE LOCAL AUTHORITY HAVING JURISDICTION. 5. CONTRACTOR TO PROVIDE AND INSTALL ALL CONTRACTOR TO PROVIDE AND INSTALL ALL NECESSARY MODULES, INTERFACE MODULES AND DEVICES REQUIRED TO PROVIDE AN OPERABLE ALARM SYSTEM IN COMPLIANCE WITH ALL CODES. 6. ACTIVATION OF ANY PULL STATION OR SMOKE ACTIVATION OF ANY PULL STATION OR SMOKE DETECTOR IN THE EMERGENCY DEPARTMENT SHALL IMMEDIATELY CAUSE THE ENTIRE BUILDING TO ENTER THE ALARM MODE. 7. UPON ENTERING THE PANEL ALARM MODE, THE ALARM UPON ENTERING THE PANEL ALARM MODE, THE ALARM INDICATING DEVICE SHALL BE ACTIVATED, AND THE DIGITAL COMMUNICATOR SHALL NOTIFY THE CENTRAL RECEIVING STATION. 8. CONTRACTOR SHALL PROVIDE ALL NECESSARY CONTRACTOR SHALL PROVIDE ALL NECESSARY ADDITIONAL RELAY DEVICES OR POWER TRANSFORMERS FOR PROPER OPERATION OF THE FAN SHUT-DOWN UNITS AND OTHER RELATED DEVICES. 9. NEW FIRE ALARM SYSTEM SHALL BE TESTED IN NEW FIRE ALARM SYSTEM SHALL BE TESTED IN ACCORDANCE WITH NFPA CODES 70, 70E, 72. 10. CONTRACTOR SHALL PROVIDE ALL ADDITIONAL CONTRACTOR SHALL PROVIDE ALL ADDITIONAL APPURTENANCES AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. MODEL NUMBERS GIVEN MAY NOT INCLUDE ALL SPECIFIC REQUIRED ACCESSORIES FOR COMPLETE INSTALLATION. 11. PROVIDE APPURTENANCES NECESSARY SUCH THAT IF PROVIDE APPURTENANCES NECESSARY SUCH THAT IF MORE THEN TWO STROBES ARE VISIBLE THEY SHALL FLASH IN SYNC. 12. ENTIRE FIRE DETECTION AND ALARM SYSTEM SHALL BE ENTIRE FIRE DETECTION AND ALARM SYSTEM SHALL BE FURNISHED AND INSTALLED BY A LICENSED ALARM CONTRACTOR. 13. CO ALARM SHALL ANNUNCIATE AS A SUPERVISORY CO ALARM SHALL ANNUNCIATE AS A SUPERVISORY CONDITION. 14. ALL AIR HANDLING SYSTEMS RATED 2,000 CFM OR ALL AIR HANDLING SYSTEMS RATED 2,000 CFM OR MORE SHALL BE PROVIDED WITH FAN SHUTDOWNS CONNECTED TO THE FIRE ALARM SYSTEM.

AutoCAD SHX Text

1. INSTALL NEW PRIMARY CONDUCTORS FROM EXISTING MANHOLE #13 TO NEW TRANSFORMERS BA & BB; NEW SECONDARY INSTALL NEW PRIMARY CONDUCTORS FROM EXISTING MANHOLE #13 TO NEW TRANSFORMERS BA & BB; NEW SECONDARY CONDUCTORS FROM NEW TRANSFORMERS BA & BB TO PULL BOX IN CRAWL SPACE; AND NEW TRANSFORMERS BA & BB AND CONCRETE PAD. 2. COORDINATE SHUTDOWN OF SWITCHBOARD BA WITH THE VA. OPEN MAIN CIRCUIT BREAKER IN SWITCHBOARD BA AND CLOSE COORDINATE SHUTDOWN OF SWITCHBOARD BA WITH THE VA. OPEN MAIN CIRCUIT BREAKER IN SWITCHBOARD BA AND CLOSE TIE BREAKER IN SWITCHBOARD B. EXISTING TRANSFORMER BB NOW FEEDS ALL OF SWITCHBOARD B. 3. DE-ENERGIZE EXISTING TRANSFORMER BA. DE-ENERGIZE EXISTING TRANSFORMER BA. 4. REMOVE PRIMARY CONDUCTORS FROM MANHOLE #13 TO EXISTING TRANSFORMER BA, CUT SECONDARY CONDUCTORS AT REMOVE PRIMARY CONDUCTORS FROM MANHOLE #13 TO EXISTING TRANSFORMER BA, CUT SECONDARY CONDUCTORS AT EXISTING PULL BOX IN SUB-BASEMENT AND REMOVE FROM PULL BOX TO EXISTING TRANSFORMER BA. 5. SPLICE NEW PRIMARY CONDUCTORS IN MANHOLE #13 AND NEW SECONDARY CONDUCTORS IN EXISTING PULL BOX IN SPLICE NEW PRIMARY CONDUCTORS IN MANHOLE #13 AND NEW SECONDARY CONDUCTORS IN EXISTING PULL BOX IN SUB-BASEMENT. 6. TURN SWITCHBOARD BA MAIN CIRCUIT BREAKER TRIP UNIT UP TO 3000A. THEN ENERGIZE NEW TRANSFORMER BA. TURN SWITCHBOARD BA MAIN CIRCUIT BREAKER TRIP UNIT UP TO 3000A. THEN ENERGIZE NEW TRANSFORMER BA. 7. COORDINATE SHUTDOWN OF SWITCHBOARD B WITH THE VA. OPEN MAIN CIRCUIT BREAKER IN SWITCHBOARD BB AND CLOSE COORDINATE SHUTDOWN OF SWITCHBOARD B WITH THE VA. OPEN MAIN CIRCUIT BREAKER IN SWITCHBOARD BB AND CLOSE MAIN BREAKER IN SWITCHBOARD BA. NEW TRANSFORMER BA NOW FEEDS ALL OF SWITCHBOARD B. 8. DE-ENERGIZE EXISTING TRANSFORMER BB. DE-ENERGIZE EXISTING TRANSFORMER BB. 9. REMOVE PRIMARY CONDUCTORS FROM MANHOLE #13 TO EXISTING TRANSFORMER BB, CUT SECONDARY CONDUCTORS AT REMOVE PRIMARY CONDUCTORS FROM MANHOLE #13 TO EXISTING TRANSFORMER BB, CUT SECONDARY CONDUCTORS AT EXISTING PULL BOX IN SUB-BASEMENT AND REMOVE FROM PULL BOX TO EXISTING TRANSFORMER BB. 10. SPLICE NEW PRIMARY CONDUCTORS IN MANHOLE #13 AND NEW SECONDARY CONDUCTORS INTO EXISTING PULL BOX IN SPLICE NEW PRIMARY CONDUCTORS IN MANHOLE #13 AND NEW SECONDARY CONDUCTORS INTO EXISTING PULL BOX IN SUB-BASEMENT. 11. TURN SWITCHBOARD BB MAIN CIRCUIT BREAKER TRIP UNIT UP TO 3000A. THEN ENERGIZE NEW TRANSFORMER BB. TURN SWITCHBOARD BB MAIN CIRCUIT BREAKER TRIP UNIT UP TO 3000A. THEN ENERGIZE NEW TRANSFORMER BB. 12. COORDINATE SHUTDOWN OF SWITCHBOARD BB WITH THE VA. OPEN TIE BREAKER IN SWITCHBOARD B AND CLOSE MAIN COORDINATE SHUTDOWN OF SWITCHBOARD BB WITH THE VA. OPEN TIE BREAKER IN SWITCHBOARD B AND CLOSE MAIN CIRCUIT BREAKER IN SWITCHBOARD BB. NEW TRANSFORMERS BA & BB ARE NOW ACTIVE AND FEED SWITCHBOARD B. 13. TURN SWITCHBOARD B TIE BREAKER TRIP UNIT UP TO 3000A. TURN SWITCHBOARD B TIE BREAKER TRIP UNIT UP TO 3000A. 14. REMOVE EXISTING TRANSFORMERS BA & BB, CONCRETE PADS, AND ALL APPURTENANCES STILL REMAINING.REMOVE EXISTING TRANSFORMERS BA & BB, CONCRETE PADS, AND ALL APPURTENANCES STILL REMAINING.

AutoCAD SHX Text INTERCOM. PROVIDE SYSTEM AND ALL APPURTENANCES IN COORDINATION WITH VA ACCESS CONTROL VENDOR. PROGRAMMING BY ACCESS CONTROL VENDOR.

AutoCAD SHX Text

IN

AutoCAD SHX Text

DA

AutoCAD SHX Text DOOR ACTIVATOR. PROVIDE ALL APPURTENANCES IN COORDINATION WITH VA ACCESS CONTROL VENDOR.

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

CATALOG #

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

318 POINT ADDRESSABLE FIRE ALARM TERMINAL BOX, 240VAC.

AutoCAD SHX Text

80 CHARACTER BACKLIT LCD REMOTE FIRE ANNUNCIATOR.

AutoCAD SHX Text

ADDRESSABLE MANUAL DUAL-ACTION PULL STATION, RED

AutoCAD SHX Text

ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR WITH 0.5% TO 2.35% SENSITIVITY

AutoCAD SHX Text STROBE WITH SELECTABLE 15,30,75,95,110,135, AND 185 CD OUTPUT. RED INDOOR USE ONLY

AutoCAD SHX Text

NFS-320E

AutoCAD SHX Text

FDU-80

AutoCAD SHX Text

NBG-12LX

AutoCAD SHX Text

FSP-851

AutoCAD SHX Text

SRL

AutoCAD SHX Text

FIRE ALARM TERMINAL BOX

AutoCAD SHX Text R.A.

AutoCAD SHX Text S

AutoCAD SHX Text

NOTIFIER BY HONEYWELL

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text PROVIDE APPURTENANCES NECESSARY SUCH THAT IF MORE THEN TWO STROBES ARE VISIBLE THEY SHALL FLASH IN SYNCH. STROBES MUST BE PLACED 15' FROM THE END OF ANY CORRIDOR.

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text S

AutoCAD SHX Text P

AutoCAD SHX Text

ADDRESSABLE CARBON MONOXIDE DETECTOR

AutoCAD SHX Text

FSCO-951

AutoCAD SHX Text

CO

AutoCAD SHX Text ADDRESSABLE NON-RELAY PHOTOELECTRIC DUCT SMOKE DETECTOR. PROVIDE WITH APPROPRIATELY SIZE METAL SAMPLING TUBE AND ALL OTHER APPURTENANCES NECESSARY FOR A COMPLETE SYSTEM. COORDINATE INSTALLATION WITH M.C.

AutoCAD SHX Text

DNR

AutoCAD SHX Text

DS

AutoCAD SHX Text

SYSTEM SENSOR

AutoCAD SHX Text SPEAKER-STROBE WITH SELECTABLE 15,30,75,95,110,135, AND 185 CD STROBE OUTPUT AND SELECTABLE 83-90 DB HORN OUTPUT. RED INDOOR USE ONLY

AutoCAD SHX Text

P2RL

AutoCAD SHX Text

SYSTEM SENSOR

AutoCAD SHX Text

SP

AutoCAD SHX Text PUBLIC ANNOUNCEMENT SPEAKER. LOOP BACK TO SYSTEM AMPLIFIER IN BUILDING 1 FIRST FLOOR. RETAIN THE SERVICES OF AN AUTHORIZED SERVICE REPRESENTATIVE TO EVALUATE EXISTING SYSTEM FOR THE ADDITIONAL LOOP AND FOR PROGRAMMING.

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

HILLROM

AutoCAD SHX Text

NM

AutoCAD SHX Text GRAPHICAL STAFF CONSOLE DESK MOUNT. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS.

AutoCAD SHX Text

HILLROM

AutoCAD SHX Text EMERGENCY BATHROOM SWITCH WITH CALL CANCEL BUTTON. PROVIDE CAT6 TO TERMINAL BLOCK OF ROOM CONTROL BOARD AND INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS.

AutoCAD SHX Text

EP

AutoCAD SHX Text

PS

AutoCAD SHX Text DOME LIGHT WITH 4 CONFIGURATION LEDS. PROVIDE CAT6 CABLE TO TERMINAL BLOCK OF ROOM CONTROL BOARD AND INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS.

AutoCAD SHX Text

NC

AutoCAD SHX Text

MODEL NUMBER

AutoCAD SHX Text

HILLROM

AutoCAD SHX Text

HILLROM

AutoCAD SHX Text SINGLE DOME LIGHT. PROVIDE CAT6 CABLE TO CONNECT TO TERMINAL BLOCK OF ROOM CONTROL BOARD AND INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS.

AutoCAD SHX Text

NC,S

AutoCAD SHX Text

HILLROM

AutoCAD SHX Text

ROOM CONTROL BOARD. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS.

AutoCAD SHX Text

HILLROM

AutoCAD SHX Text

RCB

AutoCAD SHX Text GRAPHICAL ROOM STATION WITH CODE BLUE EMERGENCY LEVER. PROVIDE CAT6 CABLE TO TERMINAL BLOCK OF ROOM CONTROL BOARD AND INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS.

AutoCAD SHX Text

HILLROM

AutoCAD SHX Text

EQ

AutoCAD SHX Text EQUIPMENT RECEPTACLE. PROVIDE CAT6 CABLE TO TERMINAL BLOCK OF ROOM CONTROL BOARD AND INSTALL PER MANUFACTURES WRITTEN INSTRUCTIONS.

AutoCAD SHX Text DUCT SMOKE DETECTOR REMOTE TEST STATION. KEYED TEST STATION WITH MULTI-COLORED LED THAT ALTERNATES BETWEEN RED & GREEN. RED INDICATES ALARM. FOR USE WITH DUCT DETECTOR BELOW. PROVIDE WITH 40 KEYS. ALL REMOTE TEST STATIONS SHALL BE KEYED THE SAME. 24VDC. 30 MA MAXIMUM ALARM CURRENT.

AutoCAD SHX Text

RTS151 KEY

AutoCAD SHX Text R/I

AutoCAD SHX Text C

AutoCAD SHX Text 300A

AutoCAD SHX Text

(4) 350 MCM, (1) #4 GND. (1) 3" CONDUIT

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text 480/277A, 400A, 3 , 4W CLOSED TRANSITION, BYPASS-ISOLATIONTYPE AUTOMATIC TRANSFER SWITCH WITH NEMA 1 ENCLOSURE AND SWITCHED NEUTRAL. PROVIDE ACCESSORIES NEEDED FOR LOAD SHEDDING, COMMUNICATION, AND CONTROLS. PROVIDE PROGRAMMING/REPROGRAMMING OF EXISTING LOAD SHED SEQUENCE AT PARALLELING SWITCHGEAR.

AutoCAD SHX Text

ATS-CR-ED&EQ

AutoCAD SHX Text

MODEL #

AutoCAD SHX Text

ASCO

AutoCAD SHX Text

7ACTBB3400NC

AutoCAD SHX Text J

AutoCAD SHX Text

JUNCTION BOX FOR HVAC CONTROL POWER, SIZE PER N.E.C.

AutoCAD SHX Text V

AutoCAD SHX Text F

AutoCAD SHX Text 60A

AutoCAD SHX Text

(4) #6, (1) #10 GND, (1) 1" CONDUIT

AutoCAD SHX Text

P2500NNC1B00

AutoCAD SHX Text

P2594NNC2C11

AutoCAD SHX Text P2520B01

AutoCAD SHX Text

P2506NNC8A00-D

AutoCAD SHX Text

P2506NNC1B00

AutoCAD SHX Text

P2599NNC1B00

AutoCAD SHX Text P2516A01

AutoCAD SHX Text

HILLROM

AutoCAD SHX Text

CB

AutoCAD SHX Text

CODE BLUE PUSH BUTTON SWITCH. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.

AutoCAD SHX Text P2520A07

AutoCAD SHX Text

WAP

AutoCAD SHX Text WIRELESS ACCESS POINT FOR GUEST PURPOSES. PROVIDE JUNCTION BOX AND (2) CAT 6A CABLES BACK TO IT CLOSET B43-6. ROUTER TO BE INSTALLED BY OTHERS.

AutoCAD SHX Text

WAP

AutoCAD SHX Text WIRELESS ACCESS POINT FOR VA MEDICAL PURPOSES. PROVIDE JUNCTION BOX AND (2) CAT 6A CABLES BACK TO BIOMEDICAL CLOSET B43-5. ROUTER TO BE INSTALLED BY OTHERS.

AutoCAD SHX Text

VA

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text ALL CONDUITS 2 " OR LARGER SHALL BE SEISMICALLY 12" OR LARGER SHALL BE SEISMICALLY BRACED PER SPECIFICATIONS.

AutoCAD SHX Text 1.

AutoCAD SHX Text A1

AutoCAD SHX Text 3000A

AutoCAD SHX Text

8 SETS: (4) 600 MCM, (1) 400 MCM GND. (1) 4" CONDUIT

AutoCAD SHX Text 500A

AutoCAD SHX Text TO SUPPLEMENT SWBD B WITH AN ADDITIONAL 500A, 4 SETS: (4) 600 MCM, (1) 400 MCM GND. (1) 4" CONDUIT

AutoCAD SHX Text A2

AutoCAD SHX Text G

AutoCAD SHX Text N/A

AutoCAD SHX Text ATS START UP SIGNALS AND COMMUNICATIONS, (4) #12, (1) CAT 6, (1) BELDEN 9842 FOUR CONDUCTOR SHIELDED CABLE, (1) 1"CONDUIT

AutoCAD SHX Text S/S

AutoCAD SHX Text

AIPHONE

AutoCAD SHX Text FLUSH MOUNTED INTERCOM SYSTEM. PROVIDE SYSTEM AND ALL APPURTENANCES IN COORDINATION WITH VA ACCESS CONTROL VENDOR. PROGRAMMING BY ACCESS CONTROL VENDOR.

AutoCAD SHX Text

IX-SSA-2RA

AutoCAD SHX Text

IN

AutoCAD SHX Text

AIPHONE

AutoCAD SHX Text

CALL STATION. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.

AutoCAD SHX Text

LESS/A

AutoCAD SHX Text

CS

AutoCAD SHX Text

AIPHONE

AutoCAD SHX Text

MASTER CALL STATION. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.

AutoCAD SHX Text

LEM01

AutoCAD SHX Text

MCS

AutoCAD SHX Text

6" SPRINKLER TAMPER SWITCH.

AutoCAD SHX Text

OSYSU

AutoCAD SHX Text

TS

AutoCAD SHX Text

POTTER

AutoCAD SHX Text

6" SPRINKLER FLOW SWITCH.

AutoCAD SHX Text

WFD60

AutoCAD SHX Text

FS

POTTER

UP

EXISTING

MORGUE

EXISTING

AREAWAY

EX

IS

TI

NG

AR

EA

W

AY

EXISTING

WAREHOUSE

B40-8

MORGUE

B43-2

ELEVATOR

RM

B41

B42

B36-1

B36-2

B39

PUBLICATIONS

B39B40-1B40-2 B40-3

MORGUE

B40-6

B40-7

B40-7

OFFICE

B43-3

ELEV.

VEST

B37-1

B37-2

B37

EMPLOYEE

GYM

C51-1 C51-2

ELEV

SW5

STAIR

SW6

STAIR

SW4

STAIR

HYMAN

HAYES

ASSOCIATES

800 TROY-SCHENECTADY

ROAD, STE 103

LATHAM, NY 12110

(518) 452-3470 www.hymanhayes.com

ENGINEERING LLP

FE PROJECT NO: 19-181

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

6/

/2

:3 9:

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

528-809

Project Director

DECEMBER 16, 2022 JDFRevisions: Date:

STRATTON VA MEDICAL CENTER

NEW EMERGENCY DEPARTMENT100% FOR BID

SRB

PROJECT

NORTH

KEY PLAN

CORE

WING 'C'

WING 'A'

WING 'D'

WING 'B'

ELECTRICAL: BASEMENT LEVEL DEMOLITION PLAN1

DEMOLITION KEYED NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING SUMP PUMP

AutoCAD SHX Text

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

ALBANY, NY

AutoCAD SHX Text

NY PROFESSIONAL ENGINEER NO. 069373-1 ISSUED 1992; EXP. 9/25

AutoCAD SHX Text E

AutoCAD SHX Text X

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text

ELECTRICAL: BASEMENT LEVEL DEMOLITION PLAN

AutoCAD SHX Text

1-ED-100

AutoCAD SHX Text REMOVE ELECTRICAL CONNECTION FROM HVAC UNIT, TO BE REMOVED BY MC, INCLUDING CIRCUIT(S) BACK TO POWER PANEL OF ORIGIN AND LABEL AS "SPARE". REMOVE EXISTING LIGHT FIXTURE AND WIRE & CONDUIT BACK TO POWER PANEL OF ORIGIN AND LABEL AS "SPARE". REMOVE EXISTING ELECTRICAL EQUIPMENT, INCLUDING CIRCUIT(S) BACK TO POWER PANEL OF ORIGIN AND LABEL AS "SPARE". DISCONNECT AND REMOVE PUMP CONTROLLER AND PREPARE FOR RELOCATION. PROTECT CONDUCTORS AND CONDUIT AND PREPARE TO EXTEND TO NEW LOCATION. SEE 1-ES-100 FOR NEW LOCATION.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VESTIBULE

EXISTING

PHARMACY

SMOKING

SHELTER

HYMAN

HAYES

ASSOCIATES

800 TROY-SCHENECTADY

ROAD, STE 103

LATHAM, NY 12110

(518) 452-3470 www.hymanhayes.com

ENGINEERING LLP

FE PROJECT NO: 19-181

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

6/

/2

:3 9:

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

528-809

Project Director

DECEMBER 16, 2022 JDFRevisions: Date:

STRATTON VA MEDICAL CENTER

NEW EMERGENCY DEPARTMENT100% FOR BID

SRB

PROJECT

NORTH

KEY PLAN

CORE

WING 'C'

WING 'A'

WING 'D'

WING 'B'

ELECTRICAL: FIRST FLOOR DEMOLITION PLAN1

DEMOLITION KEYED NOTES:

SMOKING SHELTER CHILLER RELOCATION ELECTRICAL PLAN2

GENERAL NOTES:

AutoCAD SHX Text C

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

EXISTING GEOTHERMAL WELLS & PIPING

AutoCAD SHX Text REMOVE CARD READERS IN SMOKING SHELTER INCLUDING CONDUIT AND WIRING BACK TO JUNCTION BOX. PROVIDE REPROGRAMMING OF HEAD END SECURITY COMPUTER TO REMOVE CARD READERS.

AutoCAD SHX Text

AutoCAD SHX Text K

AutoCAD SHX Text K

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

REMOVE CONNECTION TO AUTOMATIC DOOR (TYP)

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text REMOVE 2x4…