This document contains sign fabrication specifications and guidelines for a federal navigation improvement project. The specifications cover the fabrication of 4'x6' project identification signs and 48"x48" safety performance signs. The project identification signs will have a 4'x4' white section with black legend and a 2'x4' screen printed Communications Red section with the US Army Corps of Engineers signature. Both sign types will be produced on high density overlay plywood panels with cut vinyl lettering and graphics adhered following Corps standards for layout, typeface, color and dimensions. The project identification sign details include placement of information identifying the project title, location, federal and local sponsors. The safety performance sign details include standard sections for a title with first aid logo, project identification, contractor identification and replaceable plates for daily safety record updates.

View the file

Other files

File Type Posted
Bid Abstract_05-27-2021.pdf PDF
Amendment 0005_Houghtaling Island Topo.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Amendment_0002_Site Visit Sign In Sheet.pdf PDF
Amendment_0002.pdf PDF
Amendment 0001_Pre-bid site vist_directions and instructions.pdf PDF
Amendment 0001.pdf PDF
00 01 15 list of drawings.pdf PDF
00 90 01 AA list of documents.pdf PDF
00 90 01 E- Report of Operations Pipeline Dipper or Bucket Dredges.pdf PDF
AFO - 6 - Index_Notes.pdf PDF
00 90 01 C 33CFR Oil Hazardous Form.pdf PDF
00 90 01 J-Location of Ice Houses.pdf PDF
00 90 01 F-Transportation and Placement Log Mechanical Dredges.pdf PDF
01 50 00 Temp Construction Facilites Controls.pdf PDF
01 58 00 Project ID.pdf PDF
01 57 20.00 10 Environmental protection.pdf PDF
00 90 02 AA WQC PARKS .pdf PDF
01 30 00 Admin Requirments.pdf PDF
W912DS21B0007.pdf PDF
00 90 01 K-Control Points.pdf PDF
01 78 00 clouseout Submittal.pdf PDF
00 90 01 I-Sediment_Physical and Chemistry Data Reports.pdf PDF
35 20 23 dredging.pdf PDF
AFO - 3 - Houghtaling Island Topo and Site.pdf PDF
01 33 00 Submittal Procedures.pdf PDF
01 45 00.00 20 quality control.pdf PDF
01 32 01.00 10 Project Schedule.pdf PDF
00 90 01 L-SUBMITTAL REGISTER_EXAMPLE ONLY.pdf PDF
00 90 01 H-Standard specifications for silt fence.pdf PDF
01 20 00 Tech Spec3.pdf PDF
01 42 00 Sources of Reference.pdf PDF
AFO - 5 - ATB HYDRO.pdf PDF
01 22 00.00 10 measurement and payment.pdf PDF
AFO - 4 - Houghtaling Offshore Hydro.pdf PDF
00 90 02 PARKS Permit Attachement.pdf PDF
00 90 01 A-CQC Report Example.pdf PDF
00 90 01 D-Guidelines for Preparing Accident Prevention Plan.pdf PDF
01 35 26 Gov Safety Requirment.pdf PDF
35 20 29 dredge material transport.pdf PDF
AFO - 2 -location.pdf PDF
01 20 00.00 20 price and payment procedures.pdf PDF
AFO - 1 - Index.pdf PDF
00 90 01 G-Daily Site Safety and Health Inspection Log.pdf PDF
00 90 02 WQC Attachement.pdf PDF
01 11 00 summary of work2.pdf PDF
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The graphic format for this 4' x 6' sign panel follows the legend guidelines and layout as specified below. The large 4' x 4' section of the panel in the right is to be white with black legend. The 2' x 4' section of the sign on the left with the full corps Signature (reverse version) is to be screen printed Communications Red on the white background. The castle insignia will be furnished by the Government in pressure sensitive vinyl for affixing by the Contractor.

See attached sheet for fabrication and mounting guidelines.

SAMPLE:

2"

WH-RD/BK

* Refers to the U.S. Army Corps of Engineers, "Sign Standards Manual", EPS-310-1-6.

Show non-Federal local partner's name and logo - Port Authority of New York and New Jersey

CID-01 various 4' x 6' 4' x 4' HDO-3

Color Size Size Code Height Bkg/Lgd

48" Type

LegendSign Panel Post Specification Mounting

NEW YORK AND NEW JERSEY

3"

(Dimensions are in inches) 3" 21" 1" 21"

7.75"

9.5"

3" 21" 3" 42" 3"

1.875"

1.875"

1.875"

1.875"

PHASE II, CONTRACT 4, AREA 7

ELIZABETH, NEW JERSEY

4.5"

4.5"

6"

2.25"

NAVIGATION IMPROVEMENT PROJECT

NEW YORK HARBOR

KILL VAN KULL AND NEWARK BAY

CHANNELS

Construction Supervised by:

US Army Corps of Engineers

NORTH ATLANTIC DIVISION

NEW YORK DISTRICT

Construction

LOCAL SPONSORS

PORT AUTHORITY OF

right upper and lower case with

(architect, general contractor, etc.), corporate or firm name, city, state.

Use of Legend Group 5 is optional.

Color: Black

Legend Group 5a-b: One-to-five initial capitals only as shown.

Letter and word spacing to follow Corps standards.

Typeface: 1.25" Helvetica Regular Maximum line length: 21"

All typography is flush left and rag line identification of prime contractors including: type

Cross-align the first of Legend Group 4 with the first line of the Corps Signature (US Army Corps) as shown.

Color: Black Typeface: 1.5" Helvetica Regular Maximum line length: 42"

Legend Group 4: One-to two-line identification of project or facility (civil works) or name of sponsoring department (military).

Color: Black Typeface: 3" Helvetica Bold Maximum line length: 42"

Legend Group 3: One-to three-line project title legend describes the work being done under this contract.

Castle) Color: white Typeface: 1.25" Helvetica Regular

6"

PROJECT IDENTIFICATION SIGN

CIVIL PROJECT

4.5"

6.25"

10.5"

2.5"

Contractor:

Legend Group 1: One to two-line description of Corps relationship to project Color: white

District Name (optional, Place below 10.5" Reverse Signature (6"

Typeface: 1.25" Helvetica Regular Maximum line length: 19"

Legend Group 2: Division or

B

As Construction Project Identification signs Detailed specifications for and Safety Performance signs are to be HDD plywood panel preparation are pro-fabricated and installed as described vided in Appendix B.** below. The signs are to be erected at a Shown below the mounting diagram is location deignated by the contracting of- a panel layout grid with spaces provided ficer and shall conform to the size, format, for project information. Photocopy this and typographic standards. page and use as a worksheet when pre-apring sign legend orders.

The sign panels are to be fabri-cated from .75" High Density Over-lay Plywood. Panel preparation to follow HDD specifications.

Sign graphics to be prepared on a white non-reflective vinyl film with positionable adhesive backing.

All graphics except for the Com-munications Red background with Corps signature on the project sign are to be die-cut or computer-cut non-reflective vinyl, pre-spaced legends prepared in the sizes and typefaces specified and applied to the background panel following the graphic formats shown on the attached sheets.

The 2'x4' Communications Red panel (to match PMS-032) with full Corps signature (reverse ver-sion) is to be screen printed on the white background. Identifica-tion of the District or Division may be applied under the signature with white cut vinyl letters pre-pared to Corps standards. Large Construction Project Sign scale reproduction artwork for the Legend Group 1: Corps Relationship signature is provided on page 4.8

Drill and Insert six (6) .375" T-nuts from the front face of the HDD Legend Group 2: Divison/District Name

Apply graphic panel to prepared Legend Group 3: Project Title HDD plywood panel following better. Post to be 12" long. Drill six (6) .375" mounting holes in Legend Group 4: Facility Name uprights to align with T-nuts in sign

Assemble sign panel and uprights. Legend Group 5a: Contractor/A&E Legend Group 5b: Contractor /A&E Imbed assembled sign panel and

Safety Performance Sign Legend Group 1: Project Title

Fabrication and Mounting Guidelines

48"

48"

(Dimensions in inches)

** Refers to the U.S. Army Corps of Engineers, "Sign Standards Manual", EP-310-1-6.

18"

(photographically enlarge from 1.6.875" to 10.5"). ** 2.

sign panel. Position holes as 1.shown. Flange of T-nut to be flush with sign face. 2.

manufacturers' instructions. 1.

2.Sign uprights to be structural grade 4"x4" treated Douglas Fir

3.or Southern Yellow Pine. No.1 or panel. Countersink (.5") back of 1.hole to accept socket head cap screw (4"x.375"). 2.

uprights in 4" hole. Local soil con- 1. 1.ditions and/or wind loading may require bolting additional 2"x4" 2. 2.struts on inside face of uprights to reinforce installation as shown. 3. 3.

4. 4.

Legend Group 2: Contractor/A&E

1.

2.

5. 5.

1.

2.

B 2

The graphic format, color, size and type-faces used on the sign are to be reproduced exactly as specified below. The title with First Aid logo in the top section of the sign, and the performance record captions are standard for all signs of this type. Legend Group 2 and 3 below identify the project and the contractor and are to be placed on the sign as shown.

Safety record numbers are mounted on individual metal plates and are screw-mounted to the background to allow for daily revisions to posted safety performance record.

Legend Group1: Standard two-line title "safety is a Job Requirement", with (8" od.) Safety Green First Aid logo. Color: To match PMS 347 Typeface: 3" Helvetica Bold Color: Balck

NAVIGATION CHANNEL IMPROVEMENT

Legend Group 2: One- to two-line KVK & NB CHANNELS project title legend describes the PHASE II, CONTRACT 4 work being done under this contract and name of host project.

Color: Black 2.25" ELIZABETH, NEW JERSEY Typeface: 1.5" Helvetica Regular Maximum line length: 42"

2.25" Contractor:

Legend Group 3: One - to two-line identification: name of prime This project has Days without & contractor and city, state address. 1.875" operated: lost time injury 4.875" Color: Black Typeface: 1.5" Helvetica Regular Total days worked Maximum line length: 42" 1.875" on this contract 4.875"

Legend Group 4: Standard safety Lost time record captions as shown. 1.875" injuries 4.875" Color: Black

Typeface: 1.25" Helvetica Regular

Replaceable numbers are to be mounted on white .060: aluminum plates and screw-mounted to background.

Color: Black Typeface: 3" Helvetica Regular Plate size: 2.5"x.5"

All typography is flush left and rag right, upper and lower case with initial capitals only as shown.

Letter- and word-spacing to follow Corps standards.

* Refer to the U.S. Army Corps of Engineers, "Sign Standards Manual", EPS-310-1-6.

Sign Legend Post Specifications Mounting Color Type Size Size Code Height Bkg/Lgd CID-02 various HDO-3 48" WH/BK-GR

SAFETY PERFORMANCE SIGN

Safety is a Job Rquirement

3" 3"8"

3"

3"

4"

3"

10.5"

3" 31"

Dimensions inches.

3" 2" 17"

6"

3.875"

4.5"

See attached sheet for fabrication and mounting guidelines.

Panel Size 4"x4" 4"x4"

2.5" 2.5"

.875"

3.125"

.975"

2.5"