Replace Fire Alarm Control Panel - Naval Station Everett, WA
Closed Pre-Solicitation Posted
- Solicitation number
- N4425526P7000
- Agency
-
Naval Facilities Engineering Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Everett, Washington 98207, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Navy Naval Facilities Engineering Command is seeking a contractor to replace the fire alarm control panel (FACP) and associated fire protection systems at Naval Station Everett, Washington, Building 1950. The project scope encompasses replacing the existing malfunctioning fire alarm system with a new addressable combined Fire Alarm Control Panel and Mass Notification System (FA/MNS) capable of handling a minimum of 500 individually identified sensors, along with interior construction repairs, firestopping, interior finishes, electrical and mechanical work, and design and testing in accordance with D40 fire protection requirements. The contractor must provide a complete, electrically supervised system capable of notifying building occupants through tones, strobes, text messaging, and voice announcements, install a voice evacuation system with one spare backup amplifier, implement semi-flush or surface-mounted manual pull stations, and ensure compliance with anti-terrorism criteria. The contractor must also submit design drawings, activity hazard analyses, as-built documentation, and electronic operation and maintenance support information (eOMSI). The pre-solicitation notice was posted on January 7, 2026, with a deadline for questions and clarifications due on January 21, 2026.
This procurement is designated as a Total Small Business set-aside, restricting competition to qualified small business entities. The project has a 500-calendar day performance period for completion, requiring the contractor to coordinate extensively with Naval Facilities Engineering Systems Command (NAVFAC) and adhere to stringent quality control, documentation, and testing protocols outlined in the detailed Statements of Work. While the notice does not specify an exact award value, the comprehensive scope of work including system design, installation, testing, training for naval personnel, interior construction, firestopping, and complete documentation suggests a substantial contract value typical of federal fire protection system modernization projects. The contractor must comply with all applicable Navy regulations, including facility access requirements through the Real ID program and Defense Biometrics Identification System (DBIDS) procedures, and utilize the electronic Construction and Facility Support Contract Management System (eCMS) for all project documentation and submittals.
Notice text
Statement of Work Elements:
A.REPLACE FACP
1.Replace fire alarm control panel and associated devices.
B.INTERIOR CONSTRUCTION
1.Repair interior partitions and provide firestopping penetrations as needed.
C. INTERIOR FINISHES
1.Repair interior finishes as needed.
D. FIRE PROTECTION SYSTEMS
1.Provide design and perform testing in accordance with D40 requirements.
E. ELECTRICAL/MECHANICAL
1. Provide electrical and mechancial work as necessary to complete installation of FACP.
F. ELECTRONIC OPERATION AND MAINTENANCE SUPPORT INFO
1.Provide eOMSI for project.
Files
Show all 33
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Tessy control panel | Land and Maritime | Total Small Business | |
| H312--Fire Alarm Maintenance Service Contract FY27 - NEW Base + Four - 583 | Veterans Integrated Service Network 10 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity