SOW - Doc B7 - FX102 Building 1950 Monaco FARS Final Design (PDF Only).pdf
PDF 2 MB Posted
- Solicitation number
- N4425526P7000
About this file
This document is a detailed engineering design drawing for the Naval Facilities Engineering Systems Command (NAVFAC) Northwest Region, specifically focused on replacing the Harlow Fire Alarm Reporting System (FARS) for the Everett Area of Responsibility (AOR). The drawing (FX102) includes multiple technical views such as a Building 1950 Plan, Equipment Elevation, Enlarged FARS Plan, and Antenna Detail, with a scale of 1/32" = 1'.
The technical drawing provides comprehensive equipment location data, reporting zone configuration details, and a transceiver component schedule. It features equipment specifications for fire alarm and communication systems, including components from manufacturers like Harlow and Monaco. The drawing is prepared by Veltre Engineering, Inc., a fire protection engineering firm, and is dated 6/21/2024, indicating an upcoming replacement project for the naval facility's fire alarm reporting system. The document includes detailed technical annotations, equipment placement diagrams, and systematic layouts for the proposed system replacement.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FACU
H R
T
FAR
X1
CKT12
SS
H R
T
FAR
X1
CKT12
SS
INPUT OUTPUT
SPD
(N) FTC
FARS EQUIPMENT ROOM
GHR02
(E) HARLOW
REMOTE FACU
LIGHTING
SUPPRESSION
DEVICE
DTK-TSS4BTX-F
EXIST FACU
LAMP TEST
TROUBLE
DVC OFF-LINE
MICROPHONE
TROUBLE
PHONE
TROUBLE
BUSY/WAIT
PAGE
INHIBITED
PRE/POST
ANNOUNCE TONE
POWER
ALL
CALL
PAGE
ACTIVE
EVAC
AREAS
ENABLE
TELEPHONE
PAGE
PAGE
ACTIVE
ALERT
AREAS
PAGE
INACTIVE
AREAS
(N) MONACO
BT-FX
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
VELTRE ENGINEERING, INC.
FIRE PROTECTION ENGINEERING
LIFE SAFETY | CODE CONSULTING
300 DESCHUTES WAY SW, STE 210
TUMWATER, WA 98501 (360) 706-1257
CU
I
A1 BUILDING 1950 PLAN
1/32" = 1'
D1 EQUIPMENT ELEVATION
1/2" = 1'
A3 ENLARGED PLAN FARS
3/16" = 1'
1/32" = 1'-0" feet
643232 0 scale
GENERAL NOTES
REPORTING ZONE CONFIGURATION
ZONE NO DESCRIPTION ZONE NO DESCRIPTION
LOCATION AND EQUIPMENT DATA
BUILDING DESCRIPTION LEVELS ABOVE
GRADE
GROSS AREA
HARLOW LOCATIONANTENNA LOCATIONHARLOW MODEL NO. POWER
DISCONNECT
MONACO LOCATIONANTENNA LOCATIONMONACO MODEL
NO.
PRIMARY POWER
FACU LOCATION FACU MODEL NO. NOTE ADDITIONAL SCOPE
TRANSCEIVER COMPONENT SCHEDULE
QTY. MODEL DESCRIPTION MANF.
SHEET NOTES
D3 ANTENNA DETAIL
1/2" = 1'
FX102
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- N O
RT
HW
ES
T
RE
G
IO
N
RE
PL
AC
E
HA
RL
O W
F
AR
S
FO
R
EV
ER
ET
T
AO
R
A4
A3
6/21/2024
File details come from the government source that posted it. Updated .