SOW - Doc B7 - FX102 Building 1950 Monaco FARS Final Design (PDF Only).pdf

PDF 2 MB Posted

Attached to
Replace Fire Alarm Control Panel - Naval Station Everett, WA
Solicitation number
N4425526P7000
Issued by

About this file

This document is a detailed engineering design drawing for the Naval Facilities Engineering Systems Command (NAVFAC) Northwest Region, specifically focused on replacing the Harlow Fire Alarm Reporting System (FARS) for the Everett Area of Responsibility (AOR). The drawing (FX102) includes multiple technical views such as a Building 1950 Plan, Equipment Elevation, Enlarged FARS Plan, and Antenna Detail, with a scale of 1/32" = 1'.

The technical drawing provides comprehensive equipment location data, reporting zone configuration details, and a transceiver component schedule. It features equipment specifications for fire alarm and communication systems, including components from manufacturers like Harlow and Monaco. The drawing is prepared by Veltre Engineering, Inc., a fire protection engineering firm, and is dated 6/21/2024, indicating an upcoming replacement project for the naval facility's fire alarm reporting system. The document includes detailed technical annotations, equipment placement diagrams, and systematic layouts for the proposed system replacement.

View the file

Other files

File Type Posted
SOW - Doc A9 - Contractor QC Report.pdf PDF
SOW - Doc A8 - DBIDS- Acceptable ID Documents.pdf PDF
SOW - Doc A3 - Activity Hazard Analysis - COE 2016 R2.pdf PDF
SOW - Doc A4 - Submittal - Transmittal Form - 2015 R2.pdf PDF
SOW - DOC B14 - E-18 Fire Alarm - Elevator Control - 1996 (PDF Only).pdf PDF
SOW - DOC B15 - Commons Architectural Drawings.pdf PDF
SOW - Doc D2 - D40 FIRE ALARM.docx DOCX document
SOW - Doc A11 - Monthly Waste Report - 2010-10.pdf PDF
SOW - DOC B9 - M-10R1 Mech Equipment Room 1st Floor Plan - 2017 (PDF Only).pdf PDF
SOW - Doc A10 - Contractor Production Report - 2017.pdf PDF
SOW - DOC B12 - P-07 2nd Floor Plan South - Plumbing - 1996 (AutoCAD).pdf PDF
SOW - DOC B16 - Natatorium Architectural Drawings.pdf PDF
SOW - Doc B3 - E-20R3 Panel Schedules - 2009 (AutoCAD).pdf PDF
SOW - DOC B13 - P-09 Kitchen Plan - Second Floor Plumbing - 1996 (PDF Only).pdf PDF
SOW - Doc D4 - Electronic Operation and Maintenance Support Info.docx DOCX document
SOW - DOC B10 - P-10 Kitchen Equipment Piping Diagrams - 1996 (PDF Only).pdf PDF
SOW - Doc B6 - Full Set - Control Asbuilts R1 - 2017 (AutoCAD).pdf PDF
SOW - Doc A6 - SECNAV 5512_1 April 2025.pdf PDF
SOW - Doc B8 - Fire Alarm Shop Drawings - Commons and Pool Combined (AutoCAD).pdf PDF
SOW - Doc A7 - NSE - REAL ID - Identification and Citizenship Requirement.pdf PDF
SOW - Doc B4 - E-21R5 Panel Schedules - 2015 (AutoCAD).pdf PDF
SOW - Doc A5 - Time Impact Analysis.pdf PDF
SOW - Doc B5 - E-19R2 One-line Diagram - 2008 (AutoCAD).pdf PDF
SOW - Doc B2 - M-01.01R2 Schedules Pool Addition - 2017 (AutoCAD).pdf PDF
SOW - Doc A12 - eCMS Section - UFGS 01 31 23.13 20.pdf PDF
SOW - Doc A1 - Pre Proposal Inquiry Form.pdf PDF
SOW - Doc B1 - M-02R1 Mech Equipment Schedules Commons - 2017 (PDF Only).pdf PDF
SOW - Doc D3 - D50 ELECTRICAL.docx DOCX document
SOW - Doc A2 - Request For Information Form.pdf PDF
SOW - DOC B11 - P-01 Plumbing Schedules - Plans and Details - 1996 (PDF Only).pdf PDF
SOW - Doc D1 - C30 INTERIOR FINISHES.docx DOCX document
SOW - Replace Fire Alarm Control Panel B1950.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FACU

H R

T

FAR

X1

CKT12

SS

H R

T

FAR

X1

CKT12

SS

INPUT OUTPUT

SPD

(N) FTC

FARS EQUIPMENT ROOM

GHR02

(E) HARLOW

REMOTE FACU

LIGHTING

SUPPRESSION

DEVICE

DTK-TSS4BTX-F

EXIST FACU

LAMP TEST

TROUBLE

DVC OFF-LINE

MICROPHONE

TROUBLE

PHONE

TROUBLE

BUSY/WAIT

PAGE

INHIBITED

PRE/POST

ANNOUNCE TONE

POWER

ALL

CALL

PAGE

ACTIVE

EVAC

AREAS

ENABLE

TELEPHONE

PAGE

PAGE

ACTIVE

ALERT

AREAS

PAGE

INACTIVE

AREAS

(N) MONACO

BT-FX

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

VELTRE ENGINEERING, INC.

FIRE PROTECTION ENGINEERING

LIFE SAFETY | CODE CONSULTING

300 DESCHUTES WAY SW, STE 210

TUMWATER, WA 98501 (360) 706-1257

CU

I

A1 BUILDING 1950 PLAN

1/32" = 1'

D1 EQUIPMENT ELEVATION

1/2" = 1'

A3 ENLARGED PLAN FARS

3/16" = 1'

1/32" = 1'-0" feet

643232 0 scale

GENERAL NOTES

REPORTING ZONE CONFIGURATION

ZONE NO DESCRIPTION ZONE NO DESCRIPTION

LOCATION AND EQUIPMENT DATA

BUILDING DESCRIPTION LEVELS ABOVE

GRADE

GROSS AREA

HARLOW LOCATIONANTENNA LOCATIONHARLOW MODEL NO. POWER

DISCONNECT

MONACO LOCATIONANTENNA LOCATIONMONACO MODEL

NO.

PRIMARY POWER

FACU LOCATION FACU MODEL NO. NOTE ADDITIONAL SCOPE

TRANSCEIVER COMPONENT SCHEDULE

QTY. MODEL DESCRIPTION MANF.

SHEET NOTES

D3 ANTENNA DETAIL

1/2" = 1'

FX102

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

- N O

RT

HW

ES

T

RE

G

IO

N

RE

PL

AC

E

HA

RL

O W

F

AR

S

FO

R

EV

ER

ET

T

AO

R

A4

A3

6/21/2024

File details come from the government source that posted it. Updated .