Service – Fire Suppression System Testing and Certification

Open Pre-Solicitation Posted

Solicitation number
N4523A63066390
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Washington 98314, United States

Notice details come from SAM.gov. Updated .

About this opportunity

Puget Sound Naval Shipyard & Intermediate Maintenance Facility (PSNS & IMF) Contracting Department (Code 400), within the Department of the Navy and listed under Naval Supply Systems Command, is conducting market research through a sources sought notice for semi-annual confidence testing, inspection, certification, emergency trouble calls, and repair services for an ANSUL Automatic CO2 Fire Suppression System, with responses due December 7, 2026. The notice currently lists no set-aside, and states that responses will determine whether the requirement is set aside for small business in full or in part, procured through full and open competition, or procured sole-source. This is not a solicitation, and a synopsis with response instructions will be posted later.

Work is performed at Building 427 in Bremerton, Washington, protecting a plant varnish dip tank system. The tentative NAICS is 561621 with a $25.0 million size standard, and the PSC is H912. Interested firms must be active in SAM with the NAICS code in their profile.

The contractor must employ a NICET-certified special hazard technician (Level 2 or above) trained by ANSUL, serve as an authorized ANSUL stocking distributor with immediate access to replacement parts, maintain a CO2 recharging station within 50 miles of the shipyard with 24-hour recharging capability, and provide 24/7 emergency service availability. Work follows NFPA 12. Contractor personnel must maintain a NAVSEA green badge and a security clearance for the contract duration.

The period runs semi-annually from June 2027 to June 2032, with a minimum of one year and maximum of five years. Requirements include two semi-annual maintenance visits per year and response to two trouble calls per year within 24 hours. Emergency trouble calls are eight-hour visits including up to $200 in minor materials and repair parts. Task orders for unscheduled repairs shall not exceed $20,000 over the ordering period. No incumbent is named.

Notice text

SOURCES SOUGHT NOTICE

Puget Sound Naval Shipyard & Intermediate Maintenance Facility (PSNS & IMF)
 Contracting Department (Code 400)
 Requirement: Confidence Testing, Inspection, and Certification of ANSUL Automatic CO2 Fire Suppression System
 Document / PR Number: N4523A12956436

1. GENERAL INFORMATION & NOTICE DISCLAIMER

THIS IS A SOURCES SOUGHT NOTICE. THIS NOTICE IS ISSUED FOR MARKET RESEARCH PURPOSES ONLY. THIS IS NOT A SOLICITATION OR INVITATION FOR OFFERORS TO SUBMIT PROPOSALS. A SYNOPSIS OF PROPOSED CONTRACT ACTION WILL BE POSTED AT A LATER DATE WHICH WILL PROVIDE INSTRUCTIONS FOR OFFERORS TO RESPOND TO THIS OPPORTUNITY.

The Puget Sound Naval Shipyard & Intermediate Maintenance Facility (PSNS & IMF), Contracting Department (Code 400), is issuing this sources sought notice. The sources sought is being issued as a means of conducting market research to determine the interest, availability, and capability of Industry to participate in a competitive acquisition for semi-annual confidence testing, inspection, certification, emergency trouble calls, and repair services for an ANSUL Automatic CO2 Fire Suppression System protecting an industrial plant varnish dip tank system in Building 427 at PSNS & IMF, Bremerton, WA.

The tentative North American Industry Classification System (NAICS) code selected for this acquisition is 561621 (Security Systems Services - Fire Alarm Systems Sales/Installation/Servicing), , with an applicable Small Business Size Standard of 25.0M (for NAICS 561621). To be considered an interested vendor, your company should possess the applicable NAICS code in your System for Award Management (SAM) profile. Interested offerors must be active and registered in SAM at www.sam.gov.

Based on the responses received to this sources sought notice, this requirement may be set-aside for small business (in full or in part), procured through full and open competition (unrestricted), or procured on a sole-source basis. All small business set-aside categories (e.g., Small Business, 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business [SDVOSB], and Women-Owned Small Business [WOSB]) will be considered.

Telephonic inquiries will not be accepted or acknowledged. The Government will not provide evaluations, debriefs, or formal comments to companies providing sources sought responses; however, the responses received will be used to inform the Government as to the best means of procuring this requirement. FURTHER SPECIFICATIONS AND DETAILS WILL BE PROVIDED IN THE FORTHCOMING REQUEST FOR PROPOSALS (RFP) OR REQUEST FOR QUOTATIONS (RFQ).

2. SUMMARY OF REQUIREMENT & SCOPE OF WORK

  • Objective: The Contractor shall provide all necessary personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and non-personal services to perform semi-annual confidence testing, inspection, and certification on an ANSUL Automatic CO2 Fire Suppression System, as well as handle emergency trouble calls and unscheduled repairs.
  • Protected Equipment: The system protects critical industrial plant equipment (varnish dip tank system) supporting the dipping and coating of electric motor components in Shop 51. Scheduled and potential emergent fleet support requires the system to maintain a state of continuous operational readiness.
  • Place of Performance: Puget Sound Naval Shipyard & IMF, 1400 Farragut Ave, Bremerton, WA 98314, Building 427, at Column 34.
  • Period of Performance: Semi-annual service for a base period of one (1) year with options up to a total of five (5) years (anticipated execution window: June 2027 through June 2032).
  • Core Tasks & Frequencies:
  1. Scheduled Maintenance: Semi-annual onsite confidence testing and complete inspection (at 6-month intervals). Coordination requires a 20-business-day lead time to request and approve system outages. System inspection includes detectors, agent release/manual pull stations, audible/visual devices, CO2 storage containers, actuator functionality, signal verification to the monitoring station, battery voltage/standby power transfer, and operational/safety training for personnel as requested.
  2. Emergency Trouble Calls: Provision of up to two (2) emergency trouble calls per contract year. The Contractor must be capable of providing emergency service 24 hours a day, 7 days a week, and responding on-site within twenty-four (24) hours of notification. Includes up to eight (8) hours of on-site service, associated travel, and up to $200 in minor repair parts/materials.
  3. Unscheduled Inspection & Repair: On-call non-emergency repairs and fault corrections identified between scheduled maintenance visits (ordered as firm-fixed-price task orders not to exceed $20,000 across the ordering period).
  4. Reporting & Deliverables: Submission of comprehensive Service Reports within forty-eight (48) hours of visit completion, documenting compliance with NFPA 12, operational status, test results, and any required follow-on recommendations. Deliverables conform to Data Item Description DI-NDTI-80809 (CDRL A001).

3. MANDATORY CONTRACTOR SPECIAL QUALIFICATIONS & SECURITY REQUIREMENTS

Interested parties must demonstrate their ability to meet the following mandatory prerequisites:

  1. NICET Certification: Personnel performing inspection, testing, and certification must possess a current National Institute for Certification in Engineering Technologies (NICET) certification in Special Hazards Systems (Level II or above).
  2. ANSUL OEM Training & Authorization: The Contractor must be formally trained and certified by ANSUL to design, install, test, and maintain carbon dioxide fire suppression systems. The Contractor must also be an authorized ANSUL stocking distributor of clean agent/special hazards equipment to ensure immediate availability of replacement parts from inventory.
  3. CO2Recharging Facility Access: The Contractor must maintain or have direct access to a carbon dioxide recharging station located within fifty (50) miles of Puget Sound Naval Shipyard, capable of recharging the complete system within twenty-four (24) hours following a discharge event.
  4. Security Clearance & Badging: Contractor personnel performing work must possess a valid NAVSEA Green Badge at the time of proposal submission and maintain access throughout contract performance. Work is subject to shipyard security controls in accordance with DD Form 254.
  5. Applicable Codes & Standards: Full compliance with NFPA 12 (Standard on Carbon Dioxide Extinguishing Systems), NFPA 72 (National Fire Alarm and Signaling Code), 29 CFR 1910, 29 CFR 1915, and PSNS&IMF Occupational Safety and Health Manual OSH-II-9 (Lockout/Tags-Plus).

4. SUBMISSION REQUIREMENTS (CAPABILITY STATEMENT)

Interested parties are requested to submit a Capability Statement addressing the criteria below:

  1. Company Information:
  • Company Name, Address, and Website.
  • Point of Contact (Name, Title, Phone Number, and Email Address).
  • Unique Entity Identifier (UEI) number and CAGE Code.
  • Socioeconomic Business Size/Status under the identified NAICS code (e.g., Small Business, HUBZone, 8(a), SDVOSB, WOSB, Large Business).
  1. Technical Qualifications & Capabilities:
  • Confirmation of employee(s) possessing NICET Level II (or higher) in Special Hazards Systems.
  • Verification of authorized ANSUL stocking distributor status and technician ANSUL certification for CO2 systems.
  • Location of the CO2 recharging facility within 50 miles of PSNS & IMF and demonstration of 24-hour post-discharge recharge capability.
  • Demonstration of capability to provide 24/7 emergency dispatch with on-site response within 24 hours.
  • Confirmation that designated personnel currently possess or are eligible to immediately receive a NAVSEA Green Badge.
  1. Relevant Past Experience:
  • Brief summary of up to three (3) relevant projects completed within the past five (5) years demonstrating similar experience with industrial CO2 fire suppression system maintenance, testing, and certification. Include contract/project number, customer agency/company, dollar value, and scope description.

5. SUBMISSION INSTRUCTIONS

  • Format: Submissions must be in either Microsoft Word or Portable Document Format (PDF), or directly within the body of the email. Page length should not exceed five (5) pages.
  • Email Subject Line: Must read: Sources Sought Response for ANSUL CO2 Fire Suppression System - N4523A63066390
  • Submission Deadline: Submissions must be received via email no later than 7 Dec 2026, 9:00  AM PST

EMAIL ONLY. No phone calls will be accepted.

Files

File Type Posted
A5 PWS - Fire Suppression System_Redacted.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Sources Sought Response for repair and accredited ISO 17025 calibration services Bremerton, Washington 98314, United States · NAICS 811210 Naval Supply Systems Command No set-aside
VA Class Submarine Scrubbers Repair Jbphh, Hawaii 96860, United States · NAICS 336611 Naval Sea Systems Command No set-aside
U.S. Coast Guard Air Station Port Angeles Annual Fire Protection System Inspection Washington 98362, United States · NAICS 541990 — Total Small Business
J012--Dry-Type Fire Suppression System VA Palo Alto Health Care System Palo Alto CA 94304, United States · NAICS 811310 Veterans Integrated Service Network 21 No set-aside
Maintenance, Repair, and Preservation of 60DS1701 Washington, United States · NAICS 336611 Naval Supply Systems Command No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors