WVA B120 - COMBINED DRAWING - RTA part 5.pdf

PDF 31 MB Posted

Attached to
Repair Building 120 at Watervliet Arsenal (WVA), New York
Solicitation number
W912DS24R0020
Issued by

About this file

This document appears to be a solicitation for the Repair Building 120, Multi-Use Building located at Watervliet Arsenal, New York. The project will renovate a 102,000 square foot commercial and industrial building, consolidating a wood shop and general facility maintenance into one centralized facility, constructing a new modern lab facility, and providing new office space. This is a single-step "Best Value Trade Off" solicitation with a magnitude of $25M-$100M, to be awarded as a firm fixed price contract. The acquisition will involve a Project Labor Agreement. The soliciting agency is the Department of the Army Corps of Engineers Engineering District New York.

View the file

Other files

File Type Posted
Weapons Development Lab (Photo Lab sprinklers)_Bldg 120_2nd Floor_Drawing 4856-120_Sheet 36 of 79_1 Oct 71.pdf PDF
31 00 00.docx DOCX document
Miscellaneous Sprinkler Work_Bldg 120_Drawing 4782-120_Sheet 1 of 1_Aug 74.pdf PDF
Automatic Sprinkler System_Bldg 120_Drawing 2664-120_Sheet 1 of 1_Apr 52.pdf PDF
Sprinkler System Warehouse_Bldg 120_Drawing 2661-120_Sheet 1 of 1_6 Jun 45.pdf PDF
Lab 253 Work Order 7 fire protection_Bldg 120_Drawing 5877-120_Sheet M2_Apr 93.pdf PDF
C-WVA_B120_Amdt 7_C-500 Details_ UNSTAMPED.pdf PDF
C-WVA_B120_Amdt 7_C-101 Demolition Plan_ UNSTAMPED.pdf PDF
C-WVA_B120_Amdt 7_C-104 Natural Gas Service Line Plan_ UNSTAMPED.pdf PDF
33 51 15.docx DOCX document
C-WVA_B120_Amdt 7_C-102 Site Plan_ UNSTAMPED.pdf PDF
C-WVA_B120_Amdt 7_C-103 Utilities Plan_ UNSTAMPED.pdf PDF
Fire Protection_Bldg 120_Drawing 7557-6910 and 6911_Sheet 31 and 311 of 356_3 Nov 81.pdf PDF
Install Additions To Sprinkler System_Bldg 120_Drawing 5459-120_Sheet 1 of 1_Feb 84.pdf PDF
Amendment 9 W912DS24R0020.pdf PDF
Amendment 8 W912DS24R0020.pdf PDF
Amendment 8 W912DS24C0025.pdf PDF
A-606 - DOOR HARDWARE SCHEDULE_Amend7.pdf PDF
G-006 - PHASING PLAN_Amend7.pdf PDF
G-005 - PHASING PLAN_Amend7.pdf PDF
Amendment 7 W912DS24R0020.pdf PDF
G-008 - TEMPORARY BOX SHOP PLAN_Amend7.pdf PDF
A-102 - SECOND FLOOR PLAN_amend7.pdf PDF
A-605 - DOOR SCHEDULE PANEL FRAME TYPES DOOR HARDWARE SCHEDULE Amend7.pdf PDF
A-110 - ENTRY LEVEL REFLECTED CEILING PLAN_Amend7.pdf PDF
WVA B120 - Furniture Specification - RTA.pdf PDF
Site Visit Sign In Sheet 8 Aug 2024.pdf PDF
41 22 13.15.pdf PDF
Amendment 6 W912DS24R0020.pdf PDF
Amendment 5 W912DS24R0020.pdf PDF
Site Visit Sign In Sheet 24 July 2024.pdf PDF
Amendment 0004 -W912DS24R0020.pdf PDF
Amendment 3 Drawings.pdf PDF
Amendment 3 - W912DS24R0020.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 7.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 4.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 6.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 2.pdf PDF
Amendment 2 - W912DS24R0020.pdf PDF
12 35 53.19.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 3.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 1.pdf PDF
MP-WVA120_R22_PP-201.pdf PDF
MP-WVA120_R22_PP-200.pdf PDF
WVA Visitor Notificaton form - Site Visit B120 (002).pdf PDF
Amendment 1 W912DS24R0020.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 300-345.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 150-175.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 1-25.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 200-249.pdf PDF
Show 40 more

Latest 50 of 59 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F

FIRE ALARM NOTIFICATION REQUIREMENTS LEGEND

(NO HATCH) VISUAL AND AUDIBLE NOTIFICATION

REQUIRED. INTELLIGIBILITY REQUIRED. PROVIDE LED

TEXTUAL NOTIFICATION SIGNS PER UFC 4-021-01.

AUDIBLE NOTIFICATION REQUIRED. VISUAL NOTIFICATION

NOT REQUIRED. INTELLIGIBILITY REQUIRED. PROVIDE

LED TEXTUAL NOTIFICATION SIGNS PER UFC 4-021-01.

AUDIBILITY MUST BE ACHIEVED THROUGHOUT THIS

SPACE. VISUAL NOTIFICATION REQUIRED ONLY IN

SPACES WHERE THE AVERAGE AMBIENT SOUND LEVEL IS

EXPECTED TO BE GREATER THAN 105 DBA.

INTELLIGIBILITY NOT REQUIRED FOR AREAS WHERE

OCCUPANTS ARE NOT EXPECTED TO BE NORMALLY

PRESENT IF PERSONNEL CAN DETERMINE THAT A VOICE

SIGNAL IS BEING BROADCAST AND THEY MUST WALK NO

MORE THAN 50 FT TO A LOCATION MEETING CRITERIA

FOR INTELLIGIBILITY. PROVIDE LED TEXTUAL

NOTIFICATION SIGNS PER UFC 4-021-01.

FIRE ALARM SYMBOLS LEGEND

FIRE ALARM REMOTE ANNUNCIATOR

FIRE ALARM/ MASS NOTIFICATION CONTROL PANEL.

LOCAL OPERATING CONSOLE FOR MASS NOTIFICATION SYSTEM

ANN

FMCU

WALL OR CEILING MOUNTED FIRE ALARM/MNS CLEAR

COMBINATION SPEAKER/STROBE MARKED "ALERT". 75 CANDELA

RATING OR AS NOTED. WP DENOTES WEATHERPROOF.

WALL OR CEILING MOUNTED FIRE ALARM COMBINATION CLEAR

HORN/STROBE MARKED "ALERT". 75 cd RATING OR AS NOTED.

WP DENOTES WEATHERPROOF.

LED TEXTUAL NOTIFICATION SIGN. LOCATE ABOVE OR ADJACENT

TO DOORWAY UNLESS OTHERWISE NOTED.LED

CARBON MONOXIDE DETECTOR

CLEAR FIRE ALARM STROBE MARKED "ALERT"

WITH CANDELA AS INDICATED.

FIXED-TEMPERATURE RATE COMPENSATED HEAT

DETECTOR

FIRE ALARM SPEAKER. WP DENOTES WEATHERPROOF.

DUCT SMOKE DETECTOR. COORDINATE

LOCATIONS WITH MECHANICAL PLANS

SMOKE DETECTOR. TAGS AS FOLLOWS:

EL ELEVATOR RECALL FUNCTION

P PREACTION RELEASING SERVICE

ASD AIR SAMPLING SMOKE DETECTION SERVICE

CO

FIRE ALARM MANUAL PULL STATION

LOW TEMPERATURE SENSOR

WATER FLOW SWITCH

TAMPER SWITCHTS

WFS

LTS

CONTROL MODULECM

RELEASING MODULEREL

PRESSURE SWITCHPS

MONITOR MODULEMM

AIR SAMPLING SMOKE DETECTION PANEL

LOC

ASD

FIRE ALARM ABBREVIATIONS LEGEND

IAW IN ACCORDANCE WITH

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

ACU MASS NOTIFICATION AUTONOMOUS CONTROL

UNIT

MNS MASS NOTIFICATION SYSTEM

SF SQUARE FEET

DEG DEGREES

F FAHRENHEIT

OT ORDINARY TEMPERATURE

IT INTERMEDIATE TEMPERATURE

FACP FIRE ALARM CONTROL PANEL

FSCP FIRE SUPPRESSION CONTROL PANEL

FAA FIRE ALARM REMOTE ANNUNCIATOR

TCR RADIO TRANSCIEVER

CO CARBON MONOXIDE

IR INFRARED

cd CANDELA

B DENOTES BLUE LENS FOR CO DETECTION

NOTIFICATION

G DENOTES GREEN LENS FOR COMBUSTIBLE

GAS DETECTION NOTIFICATION

WP DENOTES WEATHERPROOF

EL DENOTES ELEVATOR RECALL FUNCTION

P DENOTES PREACTION RELEASING FUNCTION

ASD DENOTES AIR SAMPLING SMOKE DETECTION

SAMPLE POINT

APPLICABLE CODES AND STANDARDS

UFC 1-200-01 DOD BUILDING CODE, WITH CHANGE 2, 06/12/2023

UFC 1-200-02 HIGH PERFORMANCE AND SUSTAINABLE BUILDING REQUIREMENTS, WITH CHANGE 2, 06/01/2022

UFC 3-101-01 ARCHITECTURE, WITH CHANGE 2, 01/20/2023

UFC 3-120-10 INTERIOR DESIGN, WITH CHANGE 2, 06/15/2021

UFC 3-420-01 PLUMBING SYSTEMS, 04/01/2021

UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, WITH CHANGE 6, 05/06/2021 UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, WITH CHANGE 2, 07/30/2022

UFC 4-010-06 CYBERSECURITY OF FACILITY-RELATED CONTROL SYSTEMS

UFC 4-021-01 DESIGN AND O&M MASS NOTIFICATION SYSTEMS WITH CHANGE 1, 01/01/2010

US ARMY CORPS OF ENGINEERS ENGINEERING AND CONSTRUCTION BULLETIN 2018-17, REVISION 1 DATED 14 MAY 2020

INTERNATIONAL BUILDING CODE (IBC) 2021

INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2021

INTERNATIONAL PLUMBING CODE (IPC) 2021

NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2022

NFPA 20, STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION, 2022 NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES, 2022 NFPA 25, STANDARD FOR THE INSPECTION, TESTING, AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS, 2023

NFPA 70, NATIONAL ELECTRIC CODE, 2023

NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2022

NFPA 101, LIFE SAFETY CODE, 2021

NFPA 291, RECOMMENDED PRACTICE FOR WATER FLOW TESTING AND MARKING OF HYDRANTS, 2022 NFPA 770, STANDARD ON HYBRID (WATER AND INERT GAS) FIRE-EXTINGUISHING SYSTEMS, 2021

ARCHITECTURAL BARRIERS ACT STANDARDS (ABAAS)

(NO HATCH) DETECTION PROVIDED BY BUILDING

SPRINKLER SYSTEM.

FIRE ALARM DETECTION REQUIREMENTS LEGEND

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF ELEVATOR RECALL.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF PREACTION

SPRINKLER SYSTEM RELEASING.

PROVIDE AIR-SAMPLING SMOKE DETECTION FOR THE

PURPOSES OF ADVANCED SUPPRESSION SYSTEM

RELEASING.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF PREACTION

SPRINKLER SYSTEM RELEASING.

1. COORDINATE ALL BUILDING FIRE ALARM/MNS FUNCTIONS WITH APPLICABLE TRADES.

2. THE FIRE ALARM SYSTEM WILL MONITOR THE BENET LABS GAS DETECTION SYSTEMS FOR THE PURPOSES OF TRANSMITTING ALARMS, TROUBLE, AND SUPERVISORY SIGNALS TO THE WVA FIRE

DEPARTMENT.

3. FIRE ALARM AND MNS CIRCUIT PATHWAY SURVIVABILITY SHALL BE AS FOLLOWS:

A. PROVIDE MINIMUM PATHWAY SURVIVABILITY LEVEL 2 PER NFPA-72 FOR ALL FIRE ALARM RISERS

FROM THE FIRST FLOOR FMCU TO THE SECOND FLOOR NOTIFICATION APPLIANCE CIRCUITS.

B. PROVIDE MINIMUM PATHWAY SURVIVABILITY LEVEL 1 PER NFPA-72 FOR ALL CIRCUITS ON THE

SECOND FLOOR.

C. PROVIDE MINIMUM PATHWAY SURVIVABILITY LEVEL 1 PER NFPA-72 FOR ALL OTHER FIRE ALARM

AND MASS NOTIFICATION CIRCUITS WITHIN THE FACILITY.

FIRE ALARM GENERAL NOTES

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:4

P

M

FA001

F

IR

E A

L A

R M

-M N

S N

O T

E S

A N

D L

E G

E N

D

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

PASSENGER

ELEV

ELEV2

MECH/ELEC

0EL1

STAIR 03

0STR03

VESTIBULE

HISTORIC LOBBY

ELEV LOBBY

LOBBY

OPEN SPACE

0SH2

OPEN SPACE

0SH1

FIRE ALARM

ANNUNCIATOR

AND LOC IN

HISTORIC LOBBY

MECH ROOM

0ME1

FIRE ALARM-MNS CONTROL PANEL LOCATED IN THIS ROOM

FREIGHT

ELEVATOR

ELEV1

FIRE/WATER

SERVICE

ELEC RM

1EL2

UNASSIGNED

MECHANICAL RM

1ME1

MECHANICAL RM

1ME2

LIBRARY

TOOL ROOM

125 LEADER OFFICE

LEADER OFFICE

SUPERVISOR

OFFICE

ELECTRICAL

1EL1

TELECOM

1TL1

MECHANICS

OFFICE

TOILET

OFFICE

WOOD

TOOL STOR

BOX SHOP

PW STORAGE

PW SHOP

JANITOR

15JC1

RADIO RM

BREAK ROOM

KITCHENETTE

CORRIDOR

CLOSET

15CL1

ADMIN

FIBER SHOP

WOMENS

LOCKER RM

MENS LOCKER

RM

103STAIR 01

1STR01

STAIR 02

1STR02

JANITOR

1JC1

STAIR 05

1STR05

CORRIDOR

STAIR 04

1STR04

JANITOR

1JC2

PASS ELEV

ELEV2

CONNECTOR

101B

CORRIDOR

101A

CORRIDOR

101C

CORRIDOR

101E

CONNECTOR

101D

COPIER

2TL9

STAIR 03

1STR03

AC MECHANICS

OFFICE

ELECTRICIANS

OFFICE

WELLNESS

VESTIBULE

104A

BENET CHEM

STOR

LOADING DOCK

FIRE ALARM NOTIFICATION REQUIREMENTS LEGEND

(NO HATCH) VISUAL AND AUDIBLE NOTIFICATION

REQUIRED. INTELLIGIBILITY REQUIRED. PROVIDE LED

TEXTUAL NOTIFICATION SIGNS PER UFC 4-021-01.

AUDIBLE NOTIFICATION REQUIRED. VISUAL NOTIFICATION

NOT REQUIRED. INTELLIGIBILITY REQUIRED. PROVIDE

LED TEXTUAL NOTIFICATION SIGNS PER UFC 4-021-01.

AUDIBILITY MUST BE ACHIEVED THROUGHOUT THIS

SPACE. VISUAL NOTIFICATION REQUIRED ONLY IN

SPACES WHERE THE AVERAGE AMBIENT SOUND LEVEL IS

EXPECTED TO BE GREATER THAN 105 DBA.

INTELLIGIBILITY NOT REQUIRED FOR AREAS WHERE

OCCUPANTS ARE NOT EXPECTED TO BE NORMALLY

PRESENT IF PERSONNEL CAN DETERMINE THAT A VOICE

SIGNAL IS BEING BROADCAST AND THEY MUST WALK NO

MORE THAN 50 FT TO A LOCATION MEETING CRITERIA

FOR INTELLIGIBILITY. PROVIDE LED TEXTUAL

NOTIFICATION SIGNS PER UFC 4-021-01.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:4

P

M

FA101

E N

T R

A N

C E

A N

D F

IR

S

T F

L O

O R

F

IR

E A

L A

R M

-M N

S R

E Q

U

IR

E M

E N

T S

P L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"1

ENTRANCE FLOOR FIRE ALARM-MNS REQUIREMENTS PLAN

1/8" = 1'-0"2

FIRST FLOOR FIRE ALARM-MNS REQUIREMENTS PLAN

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

FREIGHT

ELEVATOR

ELEV1

WELLNESS

PPE

MECHANICAL

ROOM

2ME1

ELECTRICAL

2EL1

SUPERVISOR

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE

JC

2JC1ELECTRICAL

ROOM FOR LAB

2MEEL2

PPE

COMPUTATIONAL

SPACE

OPEN OFFICE

OFFICE

JC

2JC2

ELEVATOR

VESTIBULE

TELECOM

2TL2

PROCESS PREP.

AREA

QUIET LAB

BSL 2 LAB

PROCESS LAB

MAIN LAB

PUMP ROOM #2

QUIET LAB

2PU2

PUMP ROOM #1

QUIET LAB

2PU1

ELEVATOR

VESTIBULE

OFFICE

CLOSET

2CL1

NMR LAB

TOILET

202F

TOILET

202E

TOILET

202D

TOILET

202C

TOILET

202B

TOILET

202A

CORRIDOR

PANTRY

CORRIDOR

CORRIDOR

PREFUNCTION

CHEMICAL

STORAGE

STAIR 05

2STR05

SECURITY

2SE1

STAIR 01

2STR01

COPIER RM

TELECOM

2TL1

PASSENGER

ELEVATOR

ELEV2

TELECOM

2TL3

STAIR 03

2STR03

CLOSET

2CL2

STOR

230A

FIRE SERVICE RM

FIRE ALARM NOTIFICATION REQUIREMENTS LEGEND

(NO HATCH) VISUAL AND AUDIBLE NOTIFICATION

REQUIRED. INTELLIGIBILITY REQUIRED. PROVIDE LED

TEXTUAL NOTIFICATION SIGNS PER UFC 4-021-01.

AUDIBLE NOTIFICATION REQUIRED. VISUAL NOTIFICATION

NOT REQUIRED. INTELLIGIBILITY REQUIRED. PROVIDE

LED TEXTUAL NOTIFICATION SIGNS PER UFC 4-021-01.

AUDIBILITY MUST BE ACHIEVED THROUGHOUT THIS

SPACE. VISUAL NOTIFICATION REQUIRED ONLY IN

SPACES WHERE THE AVERAGE AMBIENT SOUND LEVEL IS

EXPECTED TO BE GREATER THAN 105 DBA.

INTELLIGIBILITY NOT REQUIRED FOR AREAS WHERE

OCCUPANTS ARE NOT EXPECTED TO BE NORMALLY

PRESENT IF PERSONNEL CAN DETERMINE THAT A VOICE

SIGNAL IS BEING BROADCAST AND THEY MUST WALK NO

MORE THAN 50 FT TO A LOCATION MEETING CRITERIA

FOR INTELLIGIBILITY. PROVIDE LED TEXTUAL

NOTIFICATION SIGNS PER UFC 4-021-01.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:5

P

M

FA102

S E

C O

N D

F L O

O R

F

IR

E A

L A

R M

-M N

S R

E Q

U

IR

E M

E N

T S

P L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"1

SECOND FLOOR FIRE ALARM-MNS REQUIREMENTS PLAN

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

MECHANICAL

SHAFT

3ME4

TELECOM

3TL1

CONFERENCE

X301

OFFICE

X302

MECHANICAL

3ME3

STAIR 1

3STR01

STAIR05

3STR05

ELEV CONTROL

RM

3C01

PASSENGER

ELEV

ELEV 2

TOILET

TOILET

STAIR 03

3STR03

MECHANICAL

SHAFT

3ME2

FREIGHT

ELEVATOR

MECHANICAL

SHAFT

3ME1

ELECTRICAL

3EL1

MECHANICAL

SHAFT

3ME5

FIRE SERVICE

ROOM FOR LAB

FIRE ALARM NOTIFICATION REQUIREMENTS LEGEND

(NO HATCH) VISUAL AND AUDIBLE NOTIFICATION

REQUIRED. INTELLIGIBILITY REQUIRED. PROVIDE LED

TEXTUAL NOTIFICATION SIGNS PER UFC 4-021-01.

AUDIBLE NOTIFICATION REQUIRED. VISUAL NOTIFICATION

NOT REQUIRED. INTELLIGIBILITY REQUIRED. PROVIDE

LED TEXTUAL NOTIFICATION SIGNS PER UFC 4-021-01.

AUDIBILITY MUST BE ACHIEVED THROUGHOUT THIS

SPACE. VISUAL NOTIFICATION REQUIRED ONLY IN

SPACES WHERE THE AVERAGE AMBIENT SOUND LEVEL IS

EXPECTED TO BE GREATER THAN 105 DBA.

INTELLIGIBILITY NOT REQUIRED FOR AREAS WHERE

OCCUPANTS ARE NOT EXPECTED TO BE NORMALLY

PRESENT IF PERSONNEL CAN DETERMINE THAT A VOICE

SIGNAL IS BEING BROADCAST AND THEY MUST WALK NO

MORE THAN 50 FT TO A LOCATION MEETING CRITERIA

FOR INTELLIGIBILITY. PROVIDE LED TEXTUAL

NOTIFICATION SIGNS PER UFC 4-021-01.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:5

P

M

FA103

T H

IR

D

F L O

O R

F

IR

E A

L A

R M

-M N

S R

E Q

U

IR

E M

E N

T S

P L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"1

THIRD FLOOR FIRE ALARM-MNS REQUIREMENTS PLAN

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

PROVIDE SMOKE

DETECTION FOR

ELEVATOR RECALL

PASSENGER

ELEV

ELEV2

MECH/ELEC

0EL1 STAIR 03

0STR03

VESTIBULE

HISTORIC LOBBY

ELEV LOBBY

LOBBY

OPEN SPACE

0SH2

OPEN SPACE

0SH1

FIRE ALARM

ANNUNCIATROR

AND LOC IN

VESTIBULE

MECH ROOM

0ME1

PROVIDE SMOKE DETECTOR AT LOCATION OF

FIRE ALARM CONTROL PANEL

PROVIDE SMOKE

DETECTION FOR

ELEVATOR RECALL

PROVIDE SMOKE

DETECTION FOR

ELEVATOR RECALL

PROVIDE SMOKE

DETECTION FOR

ELEVATOR RECALL

FREIGHT

ELEVATOR

ELEV1

FIRE/WATER

SERVICE

ELEC RM

1EL2

UNASSIGNED

MECHANICAL RM

1ME1

MECHANICAL RM

1ME2

LIBRARY

TOOL ROOM

125 LEADER OFFICE

LEADER OFFICE

SUPERVISOR

OFFICE

ELECTRICAL

1EL1

TELECOM

1TL1

MECHANICS

OFFICE

TOILET

OFFICE

WOOD

TOOL STOR

BOX SHOP

OFFICE

PW SHOP

JANITOR

15JC1

RADIO RM

BREAK ROOM

KITCHENETTE

CORRIDOR

CLOSET

15CL1

ADMIN

FIBER SHOP

WOMENS

LOCKER RM

MENS LOCKER

RM

103STAIR 01

1STR01

STAIR 02

1STR02

JANITOR

1JC1

STAIR 05

1STR05

CORRIDOR

STAIR 04

1STR04

JANITOR

1JC2

PASS ELEV

ELEV2

CONNECTOR

101BCORRIDOR

101A

CORRIDOR

101C

CORRIDOR

101E

CONNECTOR

101D

CORRIDOR

STAIR 03

1STR03

AC MECHANICS

OFFICE

ELECTRICIANS

OFFICE

WELLNESS

VESTIBULE

104A

PROVIDE SMOKE

DETECTION FOR

ELEVATOR RECALL

PROVIDE INTERFACE WITH

DUST COLLECTOR INTEGRAL

FIRE DETECTION AND

SUPPRESSION SYSTEMS.

BENET CHEM

STOR

LOADING DOCK

(NO HATCH) DETECTION PROVIDED BY BUILDING

SPRINKLER SYSTEM.

FIRE ALARM DETECTION REQUIREMENTS LEGEND

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF ELEVATOR RECALL.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF PREACTION

SPRINKLER SYSTEM RELEASING.

PROVIDE AIR-SAMPLING SMOKE DETECTION FOR THE

PURPOSES OF ADVANCED SUPPRESSION SYSTEM

RELEASING.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF PREACTION

SPRINKLER SYSTEM RELEASING.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:0

P

M

FA104

E N

T R

A N

C E

A N

D F

IR

S

T F

L O

O R

D E

T E

C T

IO

N

R E

Q U

IR

E

M E

N T

S P

L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"1

ENTRANCE FLOOR FIRE ALARM DETECTION REQUIREMENTS

PLAN

1/8" = 1'-0"2

FIRST FLOOR FIRE ALARM DETECTION REQUIREMENTS PLAN

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

ELEVATOR RECALL

PROVIDE SMOKE

DETECTION FOR

ELEVATOR RECALL

PROVIDE SPOT-TYPE

SMOKE DETECTION FOR

PREACTION SPRINKLER

SYSTEM RELEASE

PROVIDE SPOT-TYPE

SMOKE DETECTION FOR

PREACTION SPRINKLER

SYSTEM RELEASE

PROVIDE SPOT-TYPE

SMOKE DETECTION FOR

PREACTION SPRINKLER

SYSTEM RELEASE

PROVIDE SPOT-TYPE

SMOKE DETECTION FOR

PREACTION SPRINKLER

SYSTEM RELEASE

PROVIDE SPOT-TYPE

SMOKE DETECTION FOR

PREACTION SPRINKLER

SYSTEM RELEASE

FREIGHT

ELEVATOR

ELEV1

WELLNESS

PPE

MECHANICAL

ROOM

2ME1

ELECTRICAL

2EL1

SUPERVISOR

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE

JC

2JC1ELECTRICAL

ROOM FOR LAB

2MEEL2

PPE

COMPUTATIONAL

SPACE

215 OPEN OFFICE

OFFICE

JC

2JC2

ELEVATOR

VESTIBULE

TELECOM

2TL2

PROCESS PREP.

AREA

QUIET LAB

BSL 2 LAB

PROCESS LAB

MAIN LAB

PUMP ROOM #2

QUIET LAB

2PU2

PUMP ROOM #1

QUIET LAB

2PU1

ELEVATOR

VESTIBULE

OFFICE

CLOSET

2CL1

NMR LAB

TOILET

202F

TOILET

202E

TOILET

202D

TOILET

202C

TOILET

202B

TOILET

202A

CORRIDOR

PANTRY

CORRIDOR

CORRIDOR

PREFUNCTION

CHEMICAL

STORAGE

STAIR 05

2STR05

SECURITY

2SE1

STAIR 01

2STR01

COPIER RM

TELECOM

2TL1

PASSENGER

ELEVATOR

ELEV2

TELECOM

2TL3

STAIR 03

2STR03CLOSET

2CL2

STOR

230A

PROVIDE SPOT-TYPE

SMOKE DETECTION FOR

PREACTION SPRINKLER

SYSTEM RELEASE

FIRE SERVICE RM

(NO HATCH) DETECTION PROVIDED BY BUILDING

SPRINKLER SYSTEM.

FIRE ALARM DETECTION REQUIREMENTS LEGEND

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF ELEVATOR RECALL.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF PREACTION

SPRINKLER SYSTEM RELEASING.

PROVIDE AIR-SAMPLING SMOKE DETECTION FOR THE

PURPOSES OF ADVANCED SUPPRESSION SYSTEM

RELEASING.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF PREACTION

SPRINKLER SYSTEM RELEASING.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:1

P

M

FA105

S E

C O

N D

F L O

O R

D E

T E

C T

IO

N

R E

Q U

IR

E

M E

N T

S P

L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"1

SECOND FLOOR FIRE ALARM DETECTION REQUIREMENTS

PLAN

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

ELEVATOR RECALL

PROVIDE SMOKE

DETECTION FOR

ELEVATOR RECALL

MECHANICAL

SHAFT

3ME4

TELECOM

3TL1

CONFERENCE

X301

OFFICE

X302

MECHANICAL

3ME3

STAIR 1

3STR01

STAIR05

3STR05

ELEV CONTROL

RM

3C01

PASSENGER

ELEV

ELEV 2

TOILET

TOILET

STAIR 03

3STR03

MECHANICAL

SHAFT

3ME2

FREIGHT

ELEVATOR

MECHANICAL

SHAFT

3ME1

ELECTRICAL

3EL1

MECHANICAL

SHAFT

3ME5

FIRE SERVICE

ROOM FOR LAB

(NO HATCH) DETECTION PROVIDED BY BUILDING

SPRINKLER SYSTEM.

FIRE ALARM DETECTION REQUIREMENTS LEGEND

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF ELEVATOR RECALL.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF PREACTION

SPRINKLER SYSTEM RELEASING.

PROVIDE AIR-SAMPLING SMOKE DETECTION FOR THE

PURPOSES OF ADVANCED SUPPRESSION SYSTEM

RELEASING.

PROVIDE SMOKE DETECTION VIA SPOT-TYPE SMOKE

DETECTORS FOR THE PURPOSES OF PREACTION

SPRINKLER SYSTEM RELEASING.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:1

P

M

FA106

T H

IR

D

F L O

O R

D E

T E

C T

IO

N

R E

Q U

IR

E

M E

N T

S P

L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"1

THIRD FLOOR FIRE ALARM DETECTION REQUIREMENTS PLAN

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

A N

N

LED

LOC

L O

C

F M

C U

F

F

F

FF

F

F

F

F

F

TS

TS

TS

TS

TS

TS

TS

TS

WFS

WFS

TS

TS

WFS

WFS

LTS

LTS

LED

L E

D

L E

D

LED

L E

D

LED LED

LOC

LOC

LOC

F

F S

C P

TS

PS

CO

CO

F

C

B

A

6 7 8 9 10 11

WP

EL

PASSENGER

ELEV

ELEV2

MECH/ELEC

0EL1

STAIR 03

0STR03

VESTIBULE

HISTORIC LOBBY

ELEV LOBBY

LOBBY

OPEN SPACE

0SH2

OPEN SPACE

0SH1

MECH ROOM

0ME1

C

D

E

B

F

G

A

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16

FREIGHT

ELEVATOR

ELEV1

FIRE/WATER

SERVICE

ELEC RM

1EL2

UNASSIGNED

BENET CHEM

STOR

MECHANICAL RM

1ME1

MECHANICAL RM

1ME2

LIBRARY

TOOL ROOM

125 LEADER OFFICE

LEADER OFFICE

SUPERVISOR

OFFICE

ELECTRICAL

1EL1

TELECOM

1TL1

MECHANICS

OFFICE

TOILET

OFFICE

WOOD

TOOL STOR

BOX SHOP

OFFICE

PW SHOP

JANITOR

15JC1

RADIO RM

BREAK ROOM

KITCHENETTE

CORRIDOR

CLOSET

15CL1

ADMIN

FIBER SHOP

WOMENS

LOCKER RM

MENS LOCKER

RM

STAIR 01

1STR01

STAIR 02

1STR02

JANITOR

1JC1

STAIR 05

1STR05

CORRIDOR

STAIR 04

1STR04

JANITOR

1JC2

PASS ELEV

ELEV2

CONNECTOR

101B

CORRIDOR

101A

CORRIDOR

101C

CORRIDOR

101E

CONNECTOR

101D

STAIR 03

1STR03

AC MECHANICS

OFFICE

ELECTRICIANS

OFFICE

WELLNESS

VESTIBULE

104A

EL

EL

75WP

EL EL

15 15

15 15

15 15

75 30 30

30 30 30

30 75

A1

FP401

WP

WP

WP

WPWP

WP

E13

FP401

WP

FIRE SERVICE

ROOM

LOADING DOCK

FIRE ALARM SYMBOLS LEGEND

FIRE ALARM REMOTE ANNUNCIATOR

FIRE ALARM/ MASS NOTIFICATION CONTROL PANEL.

LOCAL OPERATING CONSOLE FOR MASS NOTIFICATION SYSTEM

ANN

FMCU

WALL OR CEILING MOUNTED FIRE ALARM/MNS CLEAR

COMBINATION SPEAKER/STROBE MARKED "ALERT". 75 CANDELA

RATING OR AS NOTED. WP DENOTES WEATHERPROOF.

WALL OR CEILING MOUNTED FIRE ALARM COMBINATION CLEAR

HORN/STROBE MARKED "ALERT". 75 cd RATING OR AS NOTED.

WP DENOTES WEATHERPROOF.

LED TEXTUAL NOTIFICATION SIGN. LOCATE ABOVE OR ADJACENT

TO DOORWAY UNLESS OTHERWISE NOTED.LED

CARBON MONOXIDE DETECTOR

CLEAR FIRE ALARM STROBE MARKED "ALERT"

WITH CANDELA AS INDICATED.

FIXED-TEMPERATURE RATE COMPENSATED HEAT

DETECTOR

FIRE ALARM SPEAKER. WP DENOTES WEATHERPROOF.

DUCT SMOKE DETECTOR. COORDINATE

LOCATIONS WITH MECHANICAL PLANS

SMOKE DETECTOR. TAGS AS FOLLOWS:

EL ELEVATOR RECALL FUNCTION

P PREACTION RELEASING SERVICE

ASD AIR SAMPLING SMOKE DETECTION SERVICE

CO

FIRE ALARM MANUAL PULL STATION

LOW TEMPERATURE SENSOR

WATER FLOW SWITCH

TAMPER SWITCHTS

WFS

LTS

CONTROL MODULECM

RELEASING MODULEREL

PRESSURE SWITCHPS

MONITOR MODULEMM

AIR SAMPLING SMOKE DETECTION PANEL

LOC

ASD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:2

P

M

FA107

E N

T R

A N

C E

A N

D F

IR

S

T F

L O

O R

F

IR

E A

L A

R M

-M N

S P

L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"1

ENTRANCE FLOOR FIRE ALARM-MNS PLAN

1/8" = 1'-0"2

FIRST FLOOR FIRE ALARM-MNS PLAN

KEYED NOTES FA107

1 FIRE PUMP ROOM WITH ASSOCIATED FIRE ALARM MONITORING DEVICES ON

SPRINKLER FITTINGS AND VALVES.

2 FIRE ALARM ANNUNCIATROR AND LOC IN ENTRYWAY

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

TS

TS

WFS

WFS

PS

PS

MM

CM

F

L E

D

LED

LOC

L O

C

L E

D

CO

CO

ASD

A S

D

A S

D

CO

CO CO

CO CO

TS

TS

MM

M M

MM

MM

MM

F

C

D

E

B

F

G

A

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16

FREIGHT

ELEVATOR

ELEV1

WELLNESS

PPE

MECHANICAL

ROOM

2ME1

ELECTRICAL

2EL1

SUPERVISOR

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE

JC

2JC1ELECTRICAL

ROOM FOR LAB

2MEEL2

PPE

COMPUTATIONAL

SPACE

OPEN OFFICE

OFFICE

JC

2JC2

ELEVATOR

VESTIBULE

TELECOM

2TL2

PROCESS PREP.

AREA

QUIET LAB

BSL 2 LAB

222PROCESS LAB

MAIN LAB

PUMP ROOM #2

QUIET LAB

2PU2

PUMP ROOM #1

QUIET LAB

2PU1

ELEVATOR

VESTIBULE

OFFICE

CLOSET

2CL1

NMR LAB

TOILET

202F

TOILET

202E

TOILET

202D

TOILET

202C

TOILET

202B

TOILET

202A

CORRIDOR

PANTRY

CORRIDOR

CORRIDOR

PREFUNCTION

CHEMICAL

STORAGE

STAIR 05

2STR05

SECURITY

2SE1

STAIR 01

2STR01

COPIER RM

TELECOM

2TL1

PASSENGER

ELEVATOR

ELEV2

TELECOM

2TL3

STAIR 03

2STR03

CLOSET

2CL2

STOR

230A

15 15 15

151515

WP

EL

EL

P P

PP

P P

PPP

PPP

P

PP

P P

PPPPPPPPP

PPP

P P P P P P

PPP

P

P

P

PP

P

P

P

P

P

P

P P P

A1

FP401

3030 30 30

EL

P

P P

P

P P

E13

FP401

303030

FIRE SERVICE RM

75 75

ASD ASD

ASDASDASD

ASD

ASD ASD

ASDASD

ASD ASD

FIRE ALARM SYMBOLS LEGEND

FIRE ALARM REMOTE ANNUNCIATOR

FIRE ALARM/ MASS NOTIFICATION CONTROL PANEL.

LOCAL OPERATING CONSOLE FOR MASS NOTIFICATION SYSTEM

ANN

FMCU

WALL OR CEILING MOUNTED FIRE ALARM/MNS CLEAR

COMBINATION SPEAKER/STROBE MARKED "ALERT". 75 CANDELA

RATING OR AS NOTED. WP DENOTES WEATHERPROOF.

WALL OR CEILING MOUNTED FIRE ALARM COMBINATION CLEAR

HORN/STROBE MARKED "ALERT". 75 cd RATING OR AS NOTED.

WP DENOTES WEATHERPROOF.

LED TEXTUAL NOTIFICATION SIGN. LOCATE ABOVE OR ADJACENT

TO DOORWAY UNLESS OTHERWISE NOTED.LED

CARBON MONOXIDE DETECTOR

CLEAR FIRE ALARM STROBE MARKED "ALERT"

WITH CANDELA AS INDICATED.

FIXED-TEMPERATURE RATE COMPENSATED HEAT

DETECTOR

FIRE ALARM SPEAKER. WP DENOTES WEATHERPROOF.

DUCT SMOKE DETECTOR. COORDINATE

LOCATIONS WITH MECHANICAL PLANS

SMOKE DETECTOR. TAGS AS FOLLOWS:

EL ELEVATOR RECALL FUNCTION

P PREACTION RELEASING SERVICE

ASD AIR SAMPLING SMOKE DETECTION SERVICE

CO

FIRE ALARM MANUAL PULL STATION

LOW TEMPERATURE SENSOR

WATER FLOW SWITCH

TAMPER SWITCHTS

WFS

LTS

CONTROL MODULECM

RELEASING MODULEREL

PRESSURE SWITCHPS

MONITOR MODULEMM

AIR SAMPLING SMOKE DETECTION PANEL

LOC

ASD

1. COORDINATE ALL BUILDING FIRE ALARM/MNS FUNCTIONS WITH APPLICABLE TRADES.

2. THE FIRE ALARM SYSTEM WILL MONITOR THE BENET LABS GAS DETECTION SYSTEMS FOR THE PURPOSES OF TRANSMITTING ALARMS, TROUBLE, AND SUPERVISORY SIGNALS TO THE WVA FIRE

DEPARTMENT.

3. FIRE ALARM AND MNS CIRCUIT PATHWAY SURVIVABILITY SHALL BE AS FOLLOWS:

A. PROVIDE MINIMUM PATHWAY SURVIVABILITY LEVEL 2 PER NFPA-72 FOR ALL FIRE ALARM RISERS

FROM THE FIRST FLOOR FMCU TO THE SECOND FLOOR NOTIFICATION APPLIANCE CIRCUITS.

B. PROVIDE MINIMUM PATHWAY SURVIVABILITY LEVEL 1 PER NFPA-72 FOR ALL CIRCUITS ON THE

SECOND FLOOR.

C. PROVIDE MINIMUM PATHWAY SURVIVABILITY LEVEL 1 PER NFPA-72 FOR ALL OTHER FIRE ALARM

AND MASS NOTIFICATION CIRCUITS WITHIN THE FACILITY.

FIRE ALARM GENERAL NOTES

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:3

P

M

FA108

S E

C O

N D

F L O

O R

F

IR

E A

L A

R M

-M N

S P

L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"1

SECOND FLOOR FIRE ALARM-MNS PLAN

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

KEYED NOTES FA108

1 PROVIDE FIRE ALARM MONITORING OF LABORATORY AIR CONTROL SYSTEM (LACS)

GAS MONITORING/DETECTION SYSTEM. BUILDING FIRE ALARM SYSTEM SHALL PROVIDE

CENTRAL STATION REPORTING TO WVA FIRE DEPARTMENT. ACTUATION OF A GAS

ALARM SHALL NOTIFY EMERGENCY SERVICES VIA THE SITEWIDE FIRE ALARM

NETWORK. REPORTING SHALL ANNUNCIATE TYPE OF GAS DETECTED. LACS FAULTS

SHALL REPORT TO THE FIRE ALARM PANEL AS A SUPERVISORY SIGNAL.

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

F FLEDLED

LOC

L O

C

CO

FSCP

F

C

D

E

B

F

G

A

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16

75 75

FREIGHT

ELEVATOR

MECHANICAL

SHAFT

3ME4

TELECOM

3TL1

CONFERENCE

X301

OFFICE

X302

MECHANICAL

3ME3

STAIR 1

3STR01

STAIR05

3STR05

ELEV CONTROL

RM

3C01

PASSENGER

ELEV

ELEV 2

TOILET

TOILET

STAIR 03

3STR03

MECHANICAL

SHAFT

3ME2

EL

EL

EL

EL

30 30

75 75 75

757575757575

MECHANICAL

SHAFT

3ME1

A1

FP401

MECHANICAL

SHAFT

3ME5

ELECTRICAL

3EL1

FIRE SERVICE

ROOM FOR LAB

FIRE ALARM SYMBOLS LEGEND

FIRE ALARM REMOTE ANNUNCIATOR

FIRE ALARM/ MASS NOTIFICATION CONTROL PANEL.

LOCAL OPERATING CONSOLE FOR MASS NOTIFICATION SYSTEM

ANN

FMCU

WALL OR CEILING MOUNTED FIRE ALARM/MNS CLEAR

COMBINATION SPEAKER/STROBE MARKED "ALERT". 75 CANDELA

RATING OR AS NOTED. WP DENOTES WEATHERPROOF.

WALL OR CEILING MOUNTED FIRE ALARM COMBINATION CLEAR

HORN/STROBE MARKED "ALERT". 75 cd RATING OR AS NOTED.

WP DENOTES WEATHERPROOF.

LED TEXTUAL NOTIFICATION SIGN. LOCATE ABOVE OR ADJACENT

TO DOORWAY UNLESS OTHERWISE NOTED.LED

CARBON MONOXIDE DETECTOR

CLEAR FIRE ALARM STROBE MARKED "ALERT"

WITH CANDELA AS INDICATED.

FIXED-TEMPERATURE RATE COMPENSATED HEAT

DETECTOR

FIRE ALARM SPEAKER. WP DENOTES WEATHERPROOF.

DUCT SMOKE DETECTOR. COORDINATE

LOCATIONS WITH MECHANICAL PLANS

SMOKE DETECTOR. TAGS AS FOLLOWS:

EL ELEVATOR RECALL FUNCTION

P PREACTION RELEASING SERVICE

ASD AIR SAMPLING SMOKE DETECTION SERVICE

CO

FIRE ALARM MANUAL PULL STATION

LOW TEMPERATURE SENSOR

WATER FLOW SWITCH

TAMPER SWITCHTS

WFS

LTS

CONTROL MODULECM

RELEASING MODULEREL

PRESSURE SWITCHPS

MONITOR MODULEMM

AIR SAMPLING SMOKE DETECTION PANEL

LOC

ASD

E

F

8 9

FREIGHT ELEV

MACHINE ROOM

4EL1

WP EL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:3

P

M

FA109

T H

IR

D

F L O

O R

A N

D R

O O

F F

IR

E

A L A

R M

-M N

S P

L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"G2

THIRD FLOOR FIRE ALARM-MNS PLAN

1/8" = 1'-0"D9

FREIGHT ELEVATOR MACHINE ROOM ROOFTOP FIRE

ALARM-MNS PLAN

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

LED

ADDRESSABLE

FIRE ALARM AND

MASS

NOTIFICATION

CONTROL PANEL

120V

MNS AUDIO

AMPLIFIER

NAC POWER

SUPPLY

120V

S P

E A

K E

R C

IR

C

U

IT

C L A

S S

A O

U T

S P

E A

K E

R C

IR

C

U

IT

C L A

S S

A R

E T

U R

N

S T

R O

B E

/N A

C C

IR

C

U

IT

C L A

S S

A O

U T

S T

R O

B E

/N A

C C

IR

C

U

IT

C L A

S S

A R

E T

U R

N

NOTIFICATION CIRCUITS

FOR "ANNOUNCEMENT"

AND "EVACUATE" LED

TEXT MESSAGES.

120V

CONNECTION

TO SITE

FIBER OPTIC

NETWORK

FIRE ALARM RISER DIAGRAM NOTES:

1. PROVIDE ADDRESSABLE FIRE ALARM CONTROL PANEL AND COMPATIBLE

MASS NOTIFICATION CONTROL PANEL.

2. REFER TO FLOOR PLAN FOR QUANTITIES & LOCATIONS OF ALL DEVICES.

3. FIRE ALARM SUPPLIER TO PROVIDE FULL SYSTEM RISER DIAGRAM FOR

APPROVAL WITH SHOP DRAWING SUBMITTAL.

4. PROVIDE ALL INTERFACE MODULES & HARDWARE REQUIRED TO

ACCOMMODATE DEVICES AS SHOWN, INCLUDING ALL APPLIANCES AND

DEVICES.

5. COORDINATE EXACT FIRE ALARM SYSTEM WIRING INCLUDING SIZES,

QUANTITIES & ROUTING WITH FIRE ALARM MANUFACTURER & SITE

CONDITIONS.

6. WIRING INDICATED ON THE RISER DIAGRAM IS DIAGRAMMATIC ONLY & IS

NOT INTENDED TO INDICATE ROUTING OR QUANTITIES OF WIRES REQUIRED.

PROVIDE WIRING FOR A COMPLETE SYSTEM AS REQUIRED BY SYSTEM

MANUFACTURER. ALL DEVICES MAY NOT BE INDICATED ON RISER DIAGRAM.

REFER TO FLOOR PLAN FOR QUANTITIES & LOCATIONS OF DEVICES.

7. NOT ALL INTERCONNECTING WIRING IS INDICATED ON RISER DIAGRAM.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

8. PROVIDE ALL REQUIRED POWER SUPPLY WIRING ON A DEDICATED CIRCUIT

FOR THE FACP.

9. COORDINATE 120V POWER AND EXACT LOCATION OF FACP WITH

ELECTRICAL CONTRACTOR.

10. WIRE FROM CONTROL PANEL TO TRANSMITTER SHALL BE MINIMUM 20

GAUGE.

11. INITIATING DEVICE CIRCUITS, SIGNALING LINE CIRCUITS, AND NOTIFICATION

APPLIANCE CIRCUITS SHALL BE CLASS A CIRCUITS.

R TS PS N2CM

PREACTION FIRE

SUPPRESSION

CONTROL PANEL

(FSCP)

120V

REL

WFS

R CM

ASD

MM

HYBRID FIRE

SUPPRESSION

CONTROL PANEL

(FSCP)

HYBRID

120V

LOCAL

OPERATING

CONSOLE

FIRE PUMP

CONTROLLER

JOCKEY PUMP

CONTROLLER

REMOTE

ANNUNCIATOR

N2 TSNC

CO

LT

PSMM CM

PIVSLC CLASS A OUT

SLC CLASS A RETURN

AUXILIARY POWER

TSWFS

F

WP

SPRINKLER WATERFLOW NOTIFICATION APPLIANCE

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:4

P

M

FA501

F

IR

E A

L A

R M

/M N

S R

IS

E

R D

IA

G

R A

M

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

D e s ig n e r

A u th o r

C h e c k e r

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

12" = 1'-0"2

FIRE ALARM/MNS RISER DIAGRAM

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

REMOVE FIRE ALARM CONTROL PANELS AND EQUIPMENT WITHIN THIS

AREA. REMOVE ALL EQUIPMENT, DEVICES, PANELS, BACK BOXES,

CONDUIT, CIRCUITS, AND ACCESSORIES.

DEMOLISH SPRINKLER WATER SERVICE ENTRANCE

EQUIPMENT BACK TO FLANGE ABOVE FLOOR. CAP AT

LIMIT OF REMOVAL. DEMOLISH FIRE PROTECTION AIR

COMPRESSORS LOCATED WITHIN THIS ROOM

DEMOLISH SPRINKLER WATER SERVICE

ENTRANCE EQUIPMENT BACK TO FLANGE

ABOVE FLOOR. CAP AT LIMIT OF REMOVAL.

FIRE PROTECTION:

• REMOVE SPRINKLER SYSTEM THROUGHOUT

BUILDING. REMOVE ALL PIPE, FITTINGS, HANGERS,

VALVES, EQUIPMENT, AND ACCESSORIES.

• AT SOUTHEAST WATER SERVICE ENTRANCE,

DEMOLISH SPRINKLER WATER SERVICE ENTRANCE

EQUIPMENT BACK TO FLANGE ABOVE FLOOR. CAP AT

LIMIT OF REMOVAL. DEMOLISH FIRE PROTECTION AIR

COMPRESSORS LOCATED WITHIN SOUTHEAST

WATER ENTRANCE ROOM.

• AT NORTHEAST WATER SERVICE ENTRANCE,

DEMOLISH SPRINKLER WATER SERVICE ENTRANCE

EQUIPMENT BACK TO FLANGE ABOVE FLOOR. CAP AT

LIMIT OF REMOVAL.

FIRE ALARM:

• REMOVE FIRE ALARM SYSTEM COMPONENTS

THROUGHOUT THE BUILDING. REMOVE ALL

EQUIPMENT, DEVICES, PANELS, BACK BOXES,

CONDUIT, CIRCUITS, AND ACCESSORIES.

• AT THE ENTRANCE LEVEL, REMOVE FIRE ALARM

CONTROL PANELS AND EQUIPMENT.

• RETURN ALL FIRE ALARM DEVICES, PANELS, AND

EQUIPMENT TO PUBLIC WORKS.

FIRE PROTECTION/ALARM DEMOLITION LEGEND

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /F

-W V

A R

.r v t

/2

/2

:3

:5

P

M

FD100

F

IR

E P

R O

T E

C T

IO

N

/A L A

R M

D E

M O

L

IT

IO

N

P L A

N S

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

C M

R

C M

R

C M

C

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/16" = 1'-0"1

ENTRANCE FLOOR FIRE PROTECTION/ALARM DEMOLITION

PLANS

1/16" = 1'-0"2

FIRST FLOOR FIRE PROTECTION/ALARM DEMOLITION PLANS

1/16" = 1'-0"3

SECOND FLOOR FIRE PROTECTION/ALARM DEMOLITION PLANS

1/16" = 1'-0"4

THIRD FLOOR FIRE PROTECTION/ALARM DEMOLITION PLANS

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/0

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/1

/2

D E

S

IG

N S

U B

M

IS

S

IO

N

/2

/2

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R T

A S

U B

M

IS

S

IO

N /0

/2

FIRE PROTECTION SCOPE OF WORK

1. PROVIDE A FIRE PROTECTION SYSTEM THROUGHOUT THE BUILDING IN ACCORDANCE WITH THE CODES AND STANDARDS LISTED IN THE CONTRACT SPECIFICATIONS AND ON THIS SHEET, AND AS INDICATED ON THE CONTRACT DRAWINGS AND THE CONTRACT SPECIFICATIONS. THE CONTRACT DOCUMENTS ESTABLISH ENGINEERING DESIGN PRECEDENCE.

A. PROVIDE SPRINKLER SYSTEM THROUGHOUT THE BUILDING. THE FIRST FLOOR INTERIOR, SECOND FLOOR OFFICES AND SUPPORT AREAS, AND THIRD FLOOR SHALL BE PROTECTED BY WET PIPE SPRINKLER SYSTEMS. THE FIRST FLOOR LOADING DOCKS SHALL BE PROTECTED BY DRY PIPE SPRINKLER SYSTEMS. SECOND FLOOR LAB AREAS SHALL BE

PROTECTED BY A SINGLE-INTERLOCK PREACTION SPRINKLER SYSTEM.

B. PROVIDE NEW WATER SERVICE FED FROM THE EXISTING SITE UNDERGROUND WATER SUPPLY NETWORK. WATER

SERVICE ENTRANCE LOCATED AT THE SOUTHEAST CORNER OF THE BUILDING.

C. REMOVE SPRINKLERS AND SPRINKLER PIPING AS INDICATED ON THESE DRAWINGS. CAP SPRINKLER PIPING AT THE LIMIT

OF REMOVAL.

2. PROVIDE A SUPPLEMENTAL HYBRID (WATER AND INERT GAS) FIRE-EXTINGUISHING SYSTEM FOR COMPUTATIONAL SPACE, NMR LAB, AND QUIET LAB ON THE SECOND FLOOR IN ACCORDANCE WITH THE CODES AND STANDARDS LISTED IN THE CONTRACT SPECIFICATIONS AND ON THIS SHEET, AND AS INDICATED ON THE CONTRACT DRAWINGS AND THE CONTRACT

SPECIFICATIONS. THE CONTRACT DOCUMENTS ESTABLISH ENGINEERING DESIGN PRECEDENCE.

A. AREAS PROVIDED WITH HYBRID SUPPRESSION/EXTINGUISHING SYSTEMS SHALL BE UL CERTIFIED OR FM APPROVED

HYBRID FIRE EXTINGUISHING SYSTEMS, NO EXCEPTIONS. NO OTHER ALTERNATIVE FIRE PROTECTION/EXTINGUISHING

SYSTEMS WILL BE PERMITTED.

B. ALL LOW PRESSURE NITROGEN PIPING SHALL BE SCHEDULE 10 BLACK STEEL, OR PER MANUFACTURER'S REQUIREMENTS. ALL WATER PIPING SHALL BE COPPER TUBING PER MANUFACTURER'S REQUIREMENTS. ALL HIGH

PRESSURE NITROGEN PIPING SHALL BE INSTALLED PER MANUFACTURER'S REQUIREMENTS.

3. INSTALL THE SYSTEM SO THAT IT IS COMPLIANT WITH THE APPLICABLE CODES AND STANDARDS, INCLUDING THOSE NOTED

ON THIS SHEET.

A. WHERE CONFLICTS OR DISCREPANCIES OCCUR BETWEEN CONTRACT DRAWINGS, SPECIFICATIONS, AND REFERENCED CODES AND STANDARDS, THE MOST STRIGINENT REQUIREMENTS SHALL APPLY TO THE CONTRACT.

4. PROVIDE PRODUCT SUBMITTALS, SHOP DRAWINGS AND HYDRAULIC CALCULATIONS FOR REVIEW AND APPROVAL IN ACCORDANCE WITH NFPA-13. REFER TO THE HYDRAULIC CALCULATIONS NOTES FOR ADDITIONAL INFORMATION. SUBMITTALS AND SHOP DRAWINGS SUBMISSIONS REQUIRING MORE THAN TWO REVIEW CYCLES DUE TO CONTRACTOR'S OR SUB- CONTRACTOR'S OWN ERRORS, OMISSIONS OR INCOMPLETENESS CAUSES ADDITIONAL EFFORTS REQUIRED BY ENGINEER (RAN FIRE PROTECTION ENGINEERING P.C.) THESE ADDITIONAL EFFORTS ARE BACK CHARGEABLE TO AND AT THE SOLE COST OF THE CONTRACTOR AND/OR SUB CONTRACTOR WHO SHALL PAY RAN'S STANDARD HOURLY RATES AS ADDITIONAL

SERVICES UNDER RAN'S CONTRACT WITH OWNER/CLIENT.

5. PROVIDE HANGING AND BRACING IN ACCORDANCE WITH NFPA-13.

6. PROVIDE SPARE SPRINKLER CABINET, SPARE SPRINKLERS, SPRINKLER WRENCH(S) AND A LIST OF INSTALLED SPRINKLERS IN

ACCORDANCE WITH NFPA-13.

7. PROVIDE ACCEPTANCE TESTING OF THE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA-13 REQUIREMENTS.

8. PROVIDE OPERATION AND MAINTENANCE (O&M) MANUAL UPON COMPLETION OF WORK. O&M MANUAL SHALL CONSIST OF AS- BUILT DRAWINGS, AS-BUILT HYDRAULIC CALCULATIONS, SYSTEM PRODUCT SUBMITTALS, AND INSTALLING CONTRACTOR'S QUALIFICATIONS AND CONTACT INFORMATION. AS-BUILT DRAWINGS SHALL BE AVAILABLE IN PDF AND AUTOCAD FORMATS.

9. CONDUCT A THOROUGH EXAMINATION OF THE PREMISES PRIOR TO PREPARING A PROPOSAL. ANY CHANGES TO THE DESIGN MADE NECESSARY BY FIELD CONDITIONS SHALL BE CONVEYED TO THE ENGINEER PRIOR TO PREPARING A PROPOSAL. NO ADDITIONAL COSTS BEYOND THE PROPOSAL PRICE WILL BE ACCEPTED FOR FIELD CONDITIONS THAT COULD HAVE BEEN

DETERMINED BY AN INSPECTION OF THE PREMISES.

HYDRAULIC CALCULATIONS NOTES

1. REFER TO HYDRAULIC CALCULATIONS SUBMISSION FOR PRELIMINARY HYDRAULIC DEMAND INFORMATION.

2. CONTRACTOR SHALL SUBMIT HYDRAULIC CALCULATIONS FOR REVIEW AND APPROVAL AS DESCRIBED IN THIS

SECTION.

3. CONTRACTOR SHALL PERFORM AND WITNESS A HYDRANT FLOW TEST WHICH SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO USE IN HYDRAULIC CALCULATIONS. USE WATER SUPPLY AS DIRECTED BY ENGINEER AFTER ENGINEER'S REVIEW OF SUBMITTED CONTRACTOR'S HYDRANT FLOW TEST DATA.

PIPE SIZES SOWN ON CONTRACT DOCUMENTS SHALL BE MAINTAINED UNLESS OTHERWISE AND SOLELY APPROVED

BY ENGINEER DURING SUBMITTAL PROCESS.

4. SPRINKLER CLASSIFICATION FOR GENERAL AND OFFICE AREAS SHALL BE "LIGHT HAZARD". SPRINKLER CLASSIFICATION FOR ALL STORAGE AND MECHANICAL ROOMS AND UPS ROOM SHALL BE "ORDINARY HAZARD".

5. PERFORM HYDRAULIC CALCULATIONS IN ACCORDANCE WITH NFPA-13 AND UFC 3-600-01 REQUIREMENTS FOR HYDRAULICALLY DESIGNED (DENSITY/AREA METHOD) SPRINKLER SYSTEMS. REDUCTIONS IN REMOTE AREAS SHALL

NOT BE PERMITTED.

DESIGN DENSITY [GPM/SF] DESIGN AREA [SF] HOSE ALLOWANCE [GPM]

LIGHT HAZARD 0.10 1,500 250

ORDINARY HAZARD 0.20 2,500 250

EXTRA HAZARD 0.30 3.500 500

6. AN INCREASE IN THE HYDRAULIC DESIGN AREA OF 30% SHALL BE APPLIED TO ALL SPRINKLER SYSTEMS PROTECTING

AREAS WITH SLOPED CEILINGS WITHOUT REVISING THE DESIGN DENSITY INDICATED ABOVE.

7. CONSTRUCTION OF THE SPRINKLER SYSTEM SHALL NOT COMMENCE UNTIL CONTRACTOR'S SHOP DRAWINGS AND HYDRAULIC CALCULATIONS HAVE BEEN APPROVED BY THE ENGINEER IN ACCORDANCE WITH NFPA-13.

8. CONTRACTOR IS RESPONSIBLE TO PROVIDE ADDITIONAL HYDRAULIC CALCULATIONS, AS REQUESTED, DURING THE

SUBMITTAL, REVIEW AND INSTALLATION PROCESS.

9. THE "SOURCE" NODE POINT IN CONTRACTOR'S HYDRAULIC CALCULATIONS SHALL BE LOCATED AT THE LOCATION OF THE FIRE PUMP DISCHARGE FLANGE. ALL PIPING AND FITTINGS BETWEEN THE BUILDING AND THE PRESSURE GAUGE HYDRANT SHALL BE INCLUDED IN THE CONTRACTOR'S HYDRAULIC CALCULATIONS. ADDITIONAL CALCULATIONS SHALL BE PROVIDED TO ENSURE THAT THE MINIMUM FIRE PUMP SUCTION PRESSURE PER NFPA-20 AND PER

MANUFACTURER'S REQUIREMENTS IS PROVIDED.

10. HYDRANTS ARE SERVED BY SITE WATER MAINS UPSTREAM OF THE FILL CONNECTION TO THE FIRE PROTECTION WATER STORAGE TANKS. OUTDOOR HOSE ALLOWANCE MAY BE OMITTED FROM CONTRACTOR'S SPRINKLER SYSTEM

HYDRAULIC CALCULATIONS PER NFPA-13.

PIPE HANGERS AND SUPPORTS

1. ACCEPTABLE PRODUCTS: ALL SUPPORT SYSTEMS ARE TO BE UL LISTED AND FM APPROVED AND INSTALLED IN

ACCORDANCE WITH NFPA-13.

2. PROVIDE COMBINATION CLEVIS TYPE HANGERS UNLESS NOTED OTHERWISE.

3. PIPE HANGERS: HEIGHT ADJUSTABLE STANDARD DUTY CLEVIS TYPE, WITH CROSS BOLT AND NUT.

4. SWIVEL RING TYPE HANGERS WILL BE ALLOWED FOR SPRINKLER PIPING UP TO A MAXIMUM OF 2 INCHES IN SIZE.

5. HANGER RODS: MILD, LOW CARBON STEEL, FULLY THREADED OR THREADED AT EACH END, WITH TWO NUTS AT

EACH END FOR POSITIONING ROD AND HANGER, AND LOCKING EACH IN PLACE.

5.1. PROVIDE HANGER ROD SIZED ACCORDING TO THE FOLLOWING SCHEDULE:

PIPE SIZE: MINIMUM ROD DIAMETER:

4" AND SMALLER 3/8"

6" OR 8" 1/2"

6. RISER CLAMPS: MALLEABLE IRON OR STEEL.

7. PIPE HANGERS OR OTHER SUPPORTS SHALL NOT BE ATTACHED TO DUCTWORK, CONDUITS, PIPES OR OTHER

CONSTRUCTURAL ELEMENTS OF THE BUILDING.

8. PROVIDE BEAM CLAMP RETAINING STRAPS ON ALL HANGERS IN BUILDINGS WHERE SEISMIC BRACING IS REQUIRED.

FIRE PROTECTION GENERAL NOTES

1. INSTALLATION WORK SHALL NOT PROCEED UNTIL SUBMITTALS HAVE BEEN RECEIVED, PROCESSED AND APPROVED IN ACCORDANCE WITH THE

REQUIREMENTS OF THE CONTRACT DRAWINGS AND THE PROJECTS SPECIFICATIONS.

2. ALL NEW VALVES ON THE FIRE PROTECTION SYSTEM TO BE ELECTRICALLY SUPERVISED. TYPE AND EXACT LOCATION OF FLOW, PRESSURE AND SUPERVISORY SWITCHES SHALL BE ACCOMPLISHED BETWEEN THE DIFFERENT RESPONSIBLE TRADES.

3. PROVIDE MAIN WATER FLOW MONITORING DEVICE ON THE FIRE PROTECTION SIDE OF SERVICE ENTRANCE, PRIOR TO ANY TEE OFFS FOR SYSTEM RISERS, FDC, TEST CONNECTIONS, ETC. CONTRACTOR IS RESPONSIBLE FOR THE ADDITION AND DELETION OF ALL WATER FLOW SWITCHES IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS, AS PART OF THIS CONTRACT BASED ON THE CONTRACTOR'S WORKING DRAWINGS.

4. COVER PLATES FOR CONCEALED PENDENT SPRINKLERS SHALL BE FACTORY PAINTED TO MATCH THE CEILING COLOR IN WHICH THEY ARE INSTALLED. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR CEILING COLORS AND COORDINATE WITH THE ARCHITECT TO

DETERMINE THE NUMBER OF COLORS REQUIRED PRIOR TO PREPARING A PROPOSAL.

5. LOCATION OF SPRINKLERS IN CEILING TILES:

A. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND ROOM FINISH SCHEDULES FOR CEILING TILE TYPES.

B. IN STANDARD 2 BY 4 CEILING TILES, LOCATE SPRINKLERS IN THE CENTER OF TILES.

C. IN STANDARD 2 BY 4 CEILING TILES WHICH SIMULATE 2 BY 2 CEILING TILES, LOCATE SPRINKLERS IN THE CENTER OF THE 2 BY 2 AREA.

6. MATERIALS:

A. ALL PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPING WITH THREADED CAST IRON FITTINGS, OR GROOVED TYPE FITTINGS AND

MECHANICAL COUPLINGS. (SCHEDULE 10 PIPE WILL NOT BE ALLOWED).

7. THE BASE BUILDING "CONTRACT DRAWINGS" AND "SPECIFICATIONS" INCLUDING ALL RESPECTIVE ADDENDA AND BULLETINS SHALL FORM A PART

OF THIS WORK, AND ALL WORK SHALL BE SUBJECT TO RESPECTIVE PROVISIONS THEREOF.

8. REFER TO ARCHITECTURAL DRAWINGS FOR HUNG CEILING HEIGHTS AND CONSTRUCTION. WHERE WORK BETWEEN THIS DRAWING AND

ARCHITECTURAL PLANS ARE IN CONFLICT, ADVISE PRIOR TO INSTALLATION OF PIPING.

9. COORDINATE WORK WITH ALL OTHER TRADES. NOTIFY ENGINEER TO AVOID CONFLICTS.

10. ADJUST AND/OR ADD SPRINKLERS AS REQUIRED UTILIZING ARCHITECT'S REFLECTED CEILING PLAN FOR LOCATION OF LIGHTS, DIFFUSERS, CABLE

TRAYS, DUCTWORK, ETC.

11. ALL EQUIPMENT SHALL BE APPROVED BY THE CONTRACTING OFFICER.

12. LAYOUT OF SPRINKLERS AND HYDRAULICS CALCULATIONS ARE FOR AUTHORITY HAVING JURISDICTION USE ONLY. SPRINKLER CONTRACTOR SHALL PREPARE FINAL SPRINKLER HEAD LAYOUT AND SHOP DRAWINGS INCLUDING HYDRAULIC CALCULATIONS AND OBTAIN ALL APPROVALS AS

REQUIRED.

13. DO NOT INSTALL ANY SPRINKLER PIPING THAT WILL INTERFERE WITH THE MAINTENANCE/REMOVAL OF HVAC EQUIPMENT.

14. DETERMINE BEST LOCATION FOR ROUTING/RE-ROUTING ALL ASSOCIATED SPRINKLER LINES. PIPE ROUTING SHOWN SHALL BE USED WHERE POSSIBLE, AND ANY ADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER TRADES, AND/OR TO MAINTAIN PROPER CLEARANCES SHALL BE PROVIDED. VERIFY EXISTING STRUCTURAL, MECHANICAL, ELECTRICAL INSTALLATIONS AND AVOID

ANY/ALL OBSTRUCTIONS OR INTERFERENCES WITH FIRE PROTECTION PIPE ROUTING.

15. ALL SPRINKLERS MOUNTED IN CEILING SHALL BE LOCATED A MINIMUM OF 4" AWAY FROM ANY WALLS, CEILING HEIGHT CHANGES OR ANY OTHER

VERTICAL INTERSECTING SURFACE.

16. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK OR OTHER OBSTRUCTIONS OVER 4 FEET IN WIDTH. FOR DUCTWORK LOCATED AGAINST WALLS, PROVIDE ADDITIONAL SPRINKLERS AS NEEDED IN ACCORDANCE WITH NFPA-13 REQUIREMENTS FOR OBSTRUCTIONS AGAINST WALLS. PROVIDE HEAD GUARDS WITH WATER SHIELDS FOR ALL SPRINKLERS INSTALLED BELOW EXPOSED DUCTWORK/OBSTRUCTIONS.

17. PROVIDE HEAD GUARDS ON SPRINKLERS IN ELECTRIC, TELEPHONE AND ELEVATOR EQUIPMENT ROOMS.

18. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE ARCHITECT.

19. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, CEILINGS, FLOORS, ROOFS, ETC. FLASH AND COUNTERFLASH ROOF PENETRATIONS.

20. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON-ACCESSIBLE CEILINGS AND CHASES.

21. METHODS OF HANGING PIPES, HEADERS AND BRANCHES SHALL BE IN ACCORDANCE WITH NFPA-13.

22. ALL VALVES FOR FIRE SERVICE SHALL BE LISTED BY THE UNDERWRITER'S LABORATORIES, INC. AND THE FACTORY MUTUAL LABORATORIES.

VALVES SHALL BE FACTORY MARKED "UL" AND "FM", 175 PSI WORKING PRESSURE.

23. ALL POWER WIRING SHALL BE ACCOMPLISHED UNDER THE ELECTRICAL DIVISION. ALL CONTROL AND INTERLOCK WIRING SHALL BE ACCOMPLISHED UNDER THIS SECTION OF THE SPECIFICATIONS IN ACCORDANCE WITH THE REQUIREMENTS IN THE ELECTRICAL DIVISION. COORDINATE ALL

ELECTRICAL ITEMS WITH ELECTRICAL CONTRACTOR.

24. SPRINKLERS SHALL COVER THE ENTIRE AREA OF THE ROOM INCLUDING ALCOVES. SPRAY SHALL NOT BE BLOCKED BY WALLS OR PARTITIONS.

25. MAINTAIN A MINIMUM OF 18 INCHES FROM THE BOTTOM OF THE SPRINKLER DEFLECTOR TO THE TOP OF STORAGE/FILE STORAGE.

26. ALL FIRE PROTECTION SYSTEMS ARE SHOWN SCHEMATICALLY. IT IS NOT THE INTENT OF THESE PLANS TO SHOW ALL LISTED COMPONENTS, SUCH AS PIPING, FITTINGS, VALVES, ETC. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SYSTEM PER APPLICABLE CODES.

27. PROVIDE A PERMANENTLY ATTACHED HYDRAULIC DESIGN INFORMATION SIGN STATING THE REQUIRED DESIGN CRITERIA FOR EACH

HYDRAULICALLY DESIGNED SYSTEM.

28. INSPECTOR'S TEST VALVE SHALL NOT EXCEED 7 FEET ABOVE THE FINISHED FLOOR.

29. PROVIDE ADEQUATE DRAINAGE FOR THE ENTIRE SPRINKLER SYSTEM AS REQUIRED BY NFPA-13, COORDINATED WITH ALL APPLICABLE BUILDING SYSTEMS. PROVIDE LOW POINT AND AUXILIARY DRAINS FOR ALL TRAPPED PIPE PER NFPA-13 REQUIREMENTS. ALL AUXILIARY DRAINS REQUIRED FOR THE COMPLETE INSTALLATION OF THE BUILDING FIRE SPRINKLER SYSTEMS SHALL BE PROVIDED AS PART OF THE BASE BID CONTRACT.

30. THE SPRINKLER PIPING LAYOUT AND PIPE SIZES SHOWN ON THE CONTRACT DOCUMENTS ARE TO DEFINE THE DESIGN INTENT FOR COMPETITIVE BIDDING AND FOR PRELIMINARY SUBMISSION TO THE AUTHORITIES HAVING JURISDICTION. THE WORK OF THE CONTRACT INCLUDES HYDRAULIC

CALCULATIONS AND FABRICATION SHOP DRAWINGS FOR THE ACTUAL INSTALLATION.

31. FLEXIBLE SPRINKLER HOSE SHALL USE BRAIDED-TYPE STEEL HOSE. CORRUGATED STEEL HOSE SHALL NOT BE ALLOWED.

32. PROVIDE AUTOMATIC AIR VENTS ON ALL WET PIPE SPRINKLER SYSTEMS IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA-13.

TESTING

1. AFTER COMPLETING THE PIPING SYSTEM, PERFORM A HYDROSTATIC TEST OF THE FIRE SPRINKLER PIPING FOR A PERIOD OF TWO HOURS AT NOT LESS THAN 200 PSI, OR AT 50 PSI IN EXCESS OF THE MAXIMUM OPERATING STATIC PRESSURE WHEN THE STATIC PRESSURE IS IN EXCESS OF 150 PSI. CHECK THE SYSTEM FOR LEAKS AND MEASURE THE HYDROSTATIC PRESSURE AT

THE LOW POINT OF EACH SYSTEM OR ZONE BEING TESTED.

2. REPAIR OR REPLACE PIPING AND FITTINGS AS REQUIRED TO ELIMINATE LEAKS IN ACCORDANCE WITH ANSI/NFPA STANDARDS

FOR "LITTLE OR NO LEAKS" AND RETEST AS SPECIFIED TO DEMONSTRATE COMPLIANCE.

3. PERFORM ALL OPERATIONAL TESTS REQUIRED FOR ACCEPTANCE BY NFPA-13, INCLUDING WATER FLOW SWITCHES, PREACTION SYSTEMS, MAIN DRAIN VALVES, CONTROL VALVES, PRESSURE-REDUCING VALVES, AND BACKFLOW PREVENTION

ASSEMBLIES.

4. UPON SATISFACTORY COMPLETION AND TESTING OF THE SYSTEM(S), PROVIDE THE OWNER WITH A LETTER CERTIFYING THAT THE SYSTEM HAS BEEN COMPLETED IN ACCORDANCE WITH ANSI/NFPA 13 STANDARDS AND IS OPERATIONAL, COMPLETE AND

WITHOUT DEFECTS.

5. IN ADDITION TO THE STANDARD HYDROSTATIC TEST, AN AIR PRESSURE LEAKAGE TEST OF THE PREACTION SPRINKLER SYSTEM SHALL BE CONDUCTED FOR 24 HOURS. ANY LEAKAGE THAT RESULTS IN A LOSS OF PRESSURE IN EXCESS OF 1.5 PSI

FOR THE 24 HOURS SHALL BE CORRECTED.

6. NITROGEN GENERATION SYSTEM SHALL BE CAPABLE OF DELIVERING A MINIMUM OF 98 PERCENT NITROGEN COMPOSITION THROUGHOUT ALL OF THE SYSTEM PIPING WITHIN 14 DAYS FROM THE COMMENCEMENT OF THE INERTING PROCESS. THIS

SHALL BE VERIFIED THROUGH SAMPLING AT THE SYSTEM NITROGEN SAMPLE PORT

QR IT UPRIGHT SPRINKLER.

K5.6 FOR LIGHT HAZARD AREAS

K8.0 FOR ORDINARY HAZARD AREAS.

QR IT CONCEALED PENDENT SPRINKLER.

K5.6 FOR LIGHT HAZARD AREAS.

K8.0 FOR ORDINARY HAZARD AREAS.

FIRE PROTECTION NOTES AND SYMBOLS LEGEND

QR IT K5.6 SIDEWALL SPRINKLER WITH HEAD GUARD.

QR IT UPRIGHT SPRINKLER.

K8.0 FOR ORDINARY HAZARD AREAS.

QR IT CONCEALED DRY PENDENT SPRINKLER.

K8.0 FOR ORDINARY HAZARD AREAS.

FIRE PROTECTION PIPING

PIPE UP

PIPE DOWN

RISER NIPPLE

K5.6 SPECIFIC APPLICATION LISTED WINDOW SPRINKLER

DRY SIDEWALL SPRINKLER WITHIN EXHAUST DUCTWORK.

APPLICABLE CODES AND STANDARDS

UFC 1-200-01 DOD BUILDING CODE, WITH CHANGE 2, 06/12/2023

UFC 1-200-02 HIGH PERFORMANCE AND SUSTAINABLE BUILDING REQUIREMENTS, WITH CHANGE 2, 06/01/2022

UFC 3-101-01 ARCHITECTURE, WITH CHANGE 2, 01/20/2023

UFC 3-120-10 INTERIOR DESIGN, WITH CHANGE 2, 06/15/2021

UFC 3-420-01 PLUMBING SYSTEMS, 04/01/2021

UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, WITH CHANGE 6, 05/06/2021 UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, WITH CHANGE 2,…

This is the start of the file's text. The full file is on GovTribe.