A-110 - ENTRY LEVEL REFLECTED CEILING PLAN_Amend7.pdf

PDF 685 KB Posted

Attached to
Repair Building 120 at Watervliet Arsenal (WVA), New York
Solicitation number
W912DS24R0020
Issued by

About this file

This document appears to be a Reflected Ceiling Plan (RCP) for the Entry Level of Building 120 at Watervliet Arsenal in New York. The RCP provides detailed information about the ceiling configuration, lighting, and HVAC elements for the ground floor of this 102,000 square foot multi-use commercial and industrial building.

The related federal contract opportunity is for the repair and renovation of Building 120 at Watervliet Arsenal. The project will consolidate a wood shop and general facility maintenance space on the ground level, construct a new modern lab facility on the second level, and provide new office space on the third level. This is a single-step "Best Value Trade Off" solicitation with an estimated contract value between $25M-$100M. The acquisition will involve a Project Labor Agreement. The contracting agency is the U.S. Army Corps of Engineers, New York District.

View the file

Other files

File Type Posted
Weapons Development Lab (Photo Lab sprinklers)_Bldg 120_2nd Floor_Drawing 4856-120_Sheet 36 of 79_1 Oct 71.pdf PDF
31 00 00.docx DOCX document
Miscellaneous Sprinkler Work_Bldg 120_Drawing 4782-120_Sheet 1 of 1_Aug 74.pdf PDF
Automatic Sprinkler System_Bldg 120_Drawing 2664-120_Sheet 1 of 1_Apr 52.pdf PDF
Sprinkler System Warehouse_Bldg 120_Drawing 2661-120_Sheet 1 of 1_6 Jun 45.pdf PDF
Lab 253 Work Order 7 fire protection_Bldg 120_Drawing 5877-120_Sheet M2_Apr 93.pdf PDF
C-WVA_B120_Amdt 7_C-500 Details_ UNSTAMPED.pdf PDF
C-WVA_B120_Amdt 7_C-101 Demolition Plan_ UNSTAMPED.pdf PDF
C-WVA_B120_Amdt 7_C-104 Natural Gas Service Line Plan_ UNSTAMPED.pdf PDF
33 51 15.docx DOCX document
C-WVA_B120_Amdt 7_C-102 Site Plan_ UNSTAMPED.pdf PDF
C-WVA_B120_Amdt 7_C-103 Utilities Plan_ UNSTAMPED.pdf PDF
Fire Protection_Bldg 120_Drawing 7557-6910 and 6911_Sheet 31 and 311 of 356_3 Nov 81.pdf PDF
Install Additions To Sprinkler System_Bldg 120_Drawing 5459-120_Sheet 1 of 1_Feb 84.pdf PDF
Amendment 9 W912DS24R0020.pdf PDF
Amendment 8 W912DS24R0020.pdf PDF
Amendment 8 W912DS24C0025.pdf PDF
A-606 - DOOR HARDWARE SCHEDULE_Amend7.pdf PDF
G-006 - PHASING PLAN_Amend7.pdf PDF
G-005 - PHASING PLAN_Amend7.pdf PDF
Amendment 7 W912DS24R0020.pdf PDF
G-008 - TEMPORARY BOX SHOP PLAN_Amend7.pdf PDF
A-102 - SECOND FLOOR PLAN_amend7.pdf PDF
A-605 - DOOR SCHEDULE PANEL FRAME TYPES DOOR HARDWARE SCHEDULE Amend7.pdf PDF
WVA B120 - Furniture Specification - RTA.pdf PDF
Site Visit Sign In Sheet 8 Aug 2024.pdf PDF
41 22 13.15.pdf PDF
Amendment 6 W912DS24R0020.pdf PDF
Amendment 5 W912DS24R0020.pdf PDF
Site Visit Sign In Sheet 24 July 2024.pdf PDF
Amendment 0004 -W912DS24R0020.pdf PDF
Amendment 3 Drawings.pdf PDF
Amendment 3 - W912DS24R0020.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 7.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 5.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 4.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 6.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 2.pdf PDF
Amendment 2 - W912DS24R0020.pdf PDF
12 35 53.19.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 3.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 1.pdf PDF
MP-WVA120_R22_PP-201.pdf PDF
MP-WVA120_R22_PP-200.pdf PDF
WVA Visitor Notificaton form - Site Visit B120 (002).pdf PDF
Amendment 1 W912DS24R0020.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 300-345.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 150-175.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 1-25.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 200-249.pdf PDF
Show 40 more

Latest 50 of 59 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C R

OS1

OS1

OS1

OS1

OS1

OS1 OS1

OS1

O S

21 3 4 5 6 7 8 9 10 11 12 13 14 15 16

C

D

E

B

F

G

A

A-302

A-302

A-302

A-302

A-311

A-301

A-301

PASSENGER

ELEV

ELEV2

MECH/ELEC

0EL1 STAIR 03

0STR03

VESTIBULE

HISTORIC LOBBY

ELEV LOBBY

A-311

A-311

A-310

@ EXPOSED

STRUCTURE

@ BAFFLE

LOBBY

004A-401

OPEN SPACE

0SH1

OPEN SPACE

0SH2

N29

N29

UNEXCAVATED

UNEXCAVATEDUNEXCAVATED

UNEXCAVATED UNEXCAVATED

9' - 4"

WD-02

8' - 1 1/2"

GC-01,PT-01

9' - 7 1/4"

PC-01,PT-01

9' - 7 1/4"

ETR

8' - 6"

GC-01,PT-01

EXPOSED

11' - 5"

PT-01,EXP

N/A

PT-01,EXP

11' - 5"

EXP

11' - 5"

EXP, PT-05

10' - 5"

N29

N36

N37

EXP

11' - 5"

MECH ROOM

0ME1

20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0"

7'

1"

5'

0"

5'

4' - 6"

8' - 4 1/2" 4' - 7"

10' - 6" 4' - 11"

4'

8'

8'

13' - 8" 13' - 8" 5' - 10"

3'

1. ALL VERTICAL SURFACES OF SOFFITS TO BE PAINTED THE SAME COLOR AS ADJACENT

WALL U.N.O.

2. ALL LAY-IN CEILING SYSTEMS SHALL BE CENTERED IN ROOM U.N.O.

3. CEILING HEIGHTS INDICATED ARE TAKEN FROM THE FINISH FLOOR ELEVATION. THE SIZE, LOCATION AND CHARACTERISTICS OF ALL MECHANICAL, ELECTRICAL AND STRUCTURAL

ITEMS SHALL BE VERIFIED BEFORE CEILING CONSTRUCTION IS BEGUN.

4. ALL DEVICES AND FIXTURES TO BE INSTALLED IN A LAY-IN CEILING TILE SYSTEM SHALL

BE LOCATED IN THE CENTER OF THE TILE U.N.O. DEVICES INCLUDE, BUT ARE NOT

LIMITED TO: RECESSED CAN LIGHTS, SPEAKERS,FIRE PROTECTION DEVICES AND

SPRINKLER HEADS.

5. COORDINATE WITH ALL TRADES IN ORDER TO MAINTAIN SCHEDULED CEILING HEIGHTS.

IN AREAS WITH NO CEILINGS, ENSURE ALL DUCTWORK, PIPING & CEILING MOUNTED

EQUIPMENT MAINTAINS A MINIMUM CLEARANCE OF 7'-0"AFF. WHERE THERE IS

UNAVOIDABLE OVERLAP, LIGHTING SHALL BE SUSPENDED AT A CONSISTENT HEIGHT

WITHIN EACH AREA SO THAT LIGHTS ARE NOT OBSTRUCTED. VERIFY THAT REQUIRED

OPERATION AND MAINTENANCE CLEARANCES ARE PROVIDED FOR ALL EQUIPMENT

ITEMS.

6. ACCESS PANELS SHALL MATCH THE FIRE RATING AND/OR ACOUSTICAL REQUIREMENTS

OF THE WALL OR CEILING.

GENERAL RCP NOTES

7. ALL CEILING DEVICES AND LIGHT FIXTURES ARE SHOWN FOR

COORDINATION PURPOSES ONLY; GRAPHICS MAY VARY FROM

MANUFACTURER'S ACTUAL MODEL. REFER TO EACH DISCIPLINE'S

DRAWINGS AND SPECIFICATIONS (MECHANICAL, ELECTRICAL, FIRE ALARM,

FIRE PROTECTION & SECURITY) FOR QUANTITIES, SPECIFIED TYPES AND

OTHER REQUIREMENTS.

8. ALL DEVICES AND FIXTURES TO BE INSTALLED SHALL BE SELF-SUPPORTING

OR HAVE REQUIRED BLOCKING PROVIDED SO THAT NO ADDITIONAL WEIGHT

BEARS ON THE FINISHED CEILING.

9. REFER TO FINISH/MATERIAL SCHEDULE FOR SINGLE SHADE HOUSING AND

DOUBLE SHADE HOUSING.

10. REFER TO SHEET A-112A FOR UNDERSLAB INSULATION AND PERFORATED

METAL PANEL EXTENT

CEILING LEGEND

RECESSED DOWNLIGHT

GYPSUM

ACOUSTICAL CEILING TILE

PENDANT LINEAR LIGHT

CYLINDRICAL PENDANT LIGHT

RECESSED SLOT LIGHTING

LIGHTING SCHEDULE, FOR LOCATION ONLY

HIGH BAY WORKSHOP LED LIGHT

UNDERSLAB SEMI RIGID

INSULATION WITH PERFORATED

METAL PANEL FINISH

WOOD SLAT CEILING

UNDERSLAB SEMI RIGID

INSULATION

FELT CEILING BAFFLES; J

MOUNTING TYPE

XX-XX CEILING MATERIAL

CEILING TAG:

RS01

RS02A

RS03

SINGLE ROLLER SUN SHADE

DUAL ROLLER SHADE, SUN &

BLACK OUT, PLASTIC CHAIN

SINGLE ROLLER BLACK OUT

SHADE

WOOD VENEER CEILING

WALL MOUNTED LINEAR

LIGHT; AT STAIRS 1,3,

AND 5

2X2 TROFFER LIGHT

CEILING HT AFF

XX-XXX' - XX" CEILING HEIGHT

REFER TO LIGHTING PLAN E304 (ETC) FOR MORE INFORMATION. MAKE NOTE THAT THIS

CONTAINS BID ALTERNATE WHERE LOOKS ARE OPTIONS FOR LIGHTING.

SPRAY CELLULOSE ACOUSTICAL

INSULATION COATING

REFER TO FINISH SCHEDULE

ON SHEET A-640 FOR COLOR

SELECTION

2x2 SUPPLY

(IN ACT CEILING)

2x2 RETURN

(IN ACT CEILING)

ROUND DIFFUSER,

SUPPLY/RETURN

1X1 EXHAUST

(IN TOILET ROOM)

SUPPLY OR RETURN

SIDE DUCT

(IN OPEN CEILING)

RS02

DUAL ROLLER SHADE, SUN &

BLACK OUT, METAL CHAIN

PLASTER

EXPOSED CEILING

EPOXY

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /A

-W V

A R

.r v t

/1

/2

:2

:5

P

M

A-110

E N

T R

Y L

E V

E L R

E F

L E

C T

E D

C E

IL

IN

G P

L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

E W

R

IG

H T

L L U

B M

C C

A R

T H

Y

E W

R

IG

H T

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1/8" = 1'-0"1

ENTRY LEVEL RCP

PLAN NORTH

8'4' 16'0

KEYNOTE LEGEND

KEY VALUE EXISTING ELEMENT(S)

08 EXISTING PLASTER CEILING TO REMAIN

KEY VALUE NEW ELEMENT(S)

N29 BOH LIGHTING REFER TO EL DRAWING SERIES

N36 NEW PLASTER CEILING WITH CROWN MOLDING, PROFILE TO MATCH EXISTING

N37 CONCEAL ALL NEW SPRINKLER PIPES ABOVE PLASTER CEILING

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M D

T

/1

/2

Sheets
A-102 - SECOND FLOOR PLAN
A-110 - ENTRY LEVEL REFLECTED CEILING PLAN
A-605 - DOOR SCHEDULE, PANEL & FRAME TYPES, DOOR HARDWARE SCHEDULE
A-606 - DOOR HARDWARE SCHEDULE

File details come from the government source that posted it. Updated .