This document is a phasing plan that outlines the construction sequence and logistics for renovating Building 120 at the Watervliet Arsenal in New York. The key details include:

The project will consolidate a wood shop and general facility maintenance workspace on the ground level into a centralized facility, construct a new modern lab facility on the second level, and provide new office space on the third level. The phasing plan specifies that the public works shops and storage must be moved to a different building during construction, and the wood box shop operations must remain fully operational at all times. The plan indicates that the emergency responder radio equipment must also remain active throughout construction, and two means of egress are required at all times. The phasing is divided into pre-construction and Phase 1A, with detailed floor plans showing the reconfiguration of spaces.

The related federal contract opportunity is for the repair and renovation of Building 120, a 102,000 square foot multi-use commercial and industrial building at the Watervliet Arsenal. The estimated contract value is between $25M-$100M, and the acquisition strategy is a single-step best value trade-off solicitation that will involve a Project Labor Agreement.

View the file

Other files

File Type Posted
Weapons Development Lab (Photo Lab sprinklers)_Bldg 120_2nd Floor_Drawing 4856-120_Sheet 36 of 79_1 Oct 71.pdf PDF
31 00 00.docx DOCX document
Miscellaneous Sprinkler Work_Bldg 120_Drawing 4782-120_Sheet 1 of 1_Aug 74.pdf PDF
Automatic Sprinkler System_Bldg 120_Drawing 2664-120_Sheet 1 of 1_Apr 52.pdf PDF
Sprinkler System Warehouse_Bldg 120_Drawing 2661-120_Sheet 1 of 1_6 Jun 45.pdf PDF
Lab 253 Work Order 7 fire protection_Bldg 120_Drawing 5877-120_Sheet M2_Apr 93.pdf PDF
C-WVA_B120_Amdt 7_C-500 Details_ UNSTAMPED.pdf PDF
C-WVA_B120_Amdt 7_C-101 Demolition Plan_ UNSTAMPED.pdf PDF
C-WVA_B120_Amdt 7_C-104 Natural Gas Service Line Plan_ UNSTAMPED.pdf PDF
33 51 15.docx DOCX document
C-WVA_B120_Amdt 7_C-102 Site Plan_ UNSTAMPED.pdf PDF
C-WVA_B120_Amdt 7_C-103 Utilities Plan_ UNSTAMPED.pdf PDF
Fire Protection_Bldg 120_Drawing 7557-6910 and 6911_Sheet 31 and 311 of 356_3 Nov 81.pdf PDF
Install Additions To Sprinkler System_Bldg 120_Drawing 5459-120_Sheet 1 of 1_Feb 84.pdf PDF
Amendment 9 W912DS24R0020.pdf PDF
Amendment 8 W912DS24R0020.pdf PDF
Amendment 8 W912DS24C0025.pdf PDF
A-606 - DOOR HARDWARE SCHEDULE_Amend7.pdf PDF
G-006 - PHASING PLAN_Amend7.pdf PDF
Amendment 7 W912DS24R0020.pdf PDF
G-008 - TEMPORARY BOX SHOP PLAN_Amend7.pdf PDF
A-102 - SECOND FLOOR PLAN_amend7.pdf PDF
A-605 - DOOR SCHEDULE PANEL FRAME TYPES DOOR HARDWARE SCHEDULE Amend7.pdf PDF
A-110 - ENTRY LEVEL REFLECTED CEILING PLAN_Amend7.pdf PDF
WVA B120 - Furniture Specification - RTA.pdf PDF
Site Visit Sign In Sheet 8 Aug 2024.pdf PDF
41 22 13.15.pdf PDF
Amendment 6 W912DS24R0020.pdf PDF
Amendment 5 W912DS24R0020.pdf PDF
Site Visit Sign In Sheet 24 July 2024.pdf PDF
Amendment 0004 -W912DS24R0020.pdf PDF
Amendment 3 Drawings.pdf PDF
Amendment 3 - W912DS24R0020.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 7.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 5.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 4.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 6.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 2.pdf PDF
Amendment 2 - W912DS24R0020.pdf PDF
12 35 53.19.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 3.pdf PDF
WVA B120 - COMBINED DRAWING - RTA part 1.pdf PDF
MP-WVA120_R22_PP-201.pdf PDF
MP-WVA120_R22_PP-200.pdf PDF
WVA Visitor Notificaton form - Site Visit B120 (002).pdf PDF
Amendment 1 W912DS24R0020.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 300-345.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 150-175.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 1-25.pdf PDF
WVA B120 - COMBINED DRAWING - RTA 200-249.pdf PDF
Show 40 more

Latest 50 of 59 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OTHERS TO MOVE PW SHOP OPERATION TO A

NEW SITE (INCLUDE FURNITURE ); NIC

OTHERS TO MOVE PW STORAGE

TO A NEW SITE (INCLUDE ALL

EQUIPMENT AND SHELVING; NIC

CLEAR ALL EQUIPMENT AND

STORED OBJECTS FROM 3RD

FLOOR - BY OTHERS

CONSOLIDATE BOX SHOP

OPERATION, REF SHEET G-008

DEMO OVERHEAD DOOR,

INFILL ROUGH OPENING WITH

TEMP WATERTIGHT INSULATED

WALL WITH AN EGRESS DOOR

TEMP SHOP(S)

STORAGE SWING

PHASING PLAN NOTES

1. GC IS RESPONSIBLE FOR FINAL PHASING PLANS AND

CONSTRUCTION SCHEDULE.

2. PHASING PLANS ARE FOR INFORMATION ONLY.

3. REFER TO SHEET G-008 FOR CRITICAL BOX SHOP PHASING.

BOX SHOP MUST BE FULLY OPERATIONAL AT ALL TIMES.

4. IT IS ALSO IMPERATIVE THAT THE EMERGENCY RESPONDER

RADIO EQUIPMENT REMAIN ACTIVE THROUGHOUT

CONSTRUCTION.

5. TWO MEANS OF EGRESS IS REQUIRED AT ALL TIMES.

SEQUENCING OF THE STAIR CONSTRUCTION MUST MAINTAIN

(2) STAIRS IN OPERATION AT ALL TIMES.

6. THE CENTER STAIR IS THE ONLY MEANS OF EGRESS FROM THE

ROOF.

AREA UNDER CONSTRUCTION

CONSTRUCTION COMPLETED

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

WVA B120

R T

A S

U B

M

IS

S

IO

N /0

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

A u to d e s k D o c s

/A U

S -0

-U

S A

C E

N

Y W

V A

B ld g R e c a p /A

-W V

A R

.r v t

/1

/2

:0

:0

P

M

G-005

P H

A S

IN

G

P L A

N

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y

N Y

D

IS

T R

IC

T

A R

C A

D

IS

U .S

I N

C

R

O U

T E

S

U

IT

E

C L

IF

T O

N P

A R

K N

Y

E W

R

IG

H T

L L U

B M

C C

A R

T H

Y

E W

R

IG

H T

/0

/2

W D

S F

W D

S D

I D

C -M

R E

C A

P

IT

A L

IZ

A T

IO

N

O F

B U

IL

D

IN

G

B

P R

O J E

C T

N O

W

D

S F

1" = 30'-0"1

ENTRANCE FLOOR

PLAN_PRECONSTRUCTION

1" = 30'-0"2

FIRST AND MEZANNINE FLOOR

PLAN_PRECONSTRUCTION

1" = 30'-0"3

SECOND FLOOR

PLAN_PRECONSTRUCTION

1" = 30'-0"4

THIRD FLOOR PLAN_PRECONSTRUCTION

PRECONSTRUCTION (BY OTHERS)

1" = 30'-0"5

ROOF PLAN_PRECONSTRUCTION

PHASE 1A

1" = 30'-0"6

ENTRANCE FLOOR PLAN_PHASE 1A

1" = 30'-0"7

FIRST AND MEZANNINE FLOOR

PLAN_PHASE 1A

MOVE PUBLIC WORKS SHOPS AND STORAGE TO BUILDING 38.

1" = 30'-0"8

SECOND FLOOR PLAN_PHASE 1A

1" = 30'-0"9

THIRD FLOOR PLAN_PHASE 1A

1" = 30'-0"10

ROOF PLAN_PHASE 1A

WOOD BOX SHOP TOOLS, STORAGE, OFFICES WILL BE CONSOLIDATED ON THE WEST HALF OF THE CURRENT WOOD BOX SHOP. FLOOR PLAN INCLUDING THE METAL ENCLOSED AREA ON THE ORIGINAL LOADING DOCK WHERE WOOD IS

CURRENTLY STORED.

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M D

T

/1

/2

Sheets
G-005 - PHASING PLAN
G-008 - TEMPORARY BOX SHOP PLAN

File details come from the government source that posted it. Updated .