A-605 - DOOR SCHEDULE PANEL FRAME TYPES DOOR HARDWARE SCHEDULE Amend7.pdf
PDF 571 KB Posted
- Solicitation number
- W912DS24R0020
About this file
This document is a door schedule, panel and frame types, and door hardware schedule for the Repair Building 120, Multi-Use Building project at the Watervliet Arsenal in New York. The project will renovate a 102,000 square foot building, consolidating a wood shop and facility maintenance space on the ground level, constructing a new lab facility on the second level, and providing new office space on the third level. The door schedule details the door sizes, types, materials, frames, ratings, and hardware requirements for the various rooms and spaces throughout the building. Key door types include solid flush, glass, and overhead rolling/coiling doors, with a range of fire and acoustic ratings. The hardware schedule specifies the required components such as closers, locksets, exit devices, and electronic access controls for the different door applications. This information is provided to support the broader Repair Building 120 project, which is a $25M-$100M solicitation issued by the U.S. Army Corps of Engineers New York District.
View the file
Other files
Show 40 more
Latest 50 of 59 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A, AA
SOLID FLUSH
F, FF
FULL LITE
6" 6"
G, GG
GLASS DOOR FOR ALL
GLASS WALL
PER MANUFACTURER
H, HH
GLASS W/ FULL RAIL
D, DD
VISION LITE
M
IN
EQ 10" EQ
M A
X
B, BB
HALF LITE
6"6"
NARROW LITE
C, CC
100 SQ/IN
MAX
M A
X
4" 6"
2" 2"
" 4
2" 2" 2" 2"
AS SHOWN
1' - 10" OR
2"
1 2 3
DOUBLE
PANE
VISION
GLAZING
S
OVERHEAD ROLLING/
COILING
1. FOR HEIGHT AND WIDTH OF DOOR, DOOR PAIRS, AND DOOR
OPENINGS, SEE SCHEDULE UNLESS OTHERWISE NOTED.
2. FOR GLAZING, SEE SCHEDULE UNLESS OTHERWISE NOTED.
3. COORDINATE SIZE OF DOORS TO BE INSTALLED IN EXISTING ROUGH
OPENINGS.
4. ALL DOORS TO BE 1 3/4" THICK, UON
5. SHOP FINISH ON STEEL SURFACES.
6. PROVIDE LINTELS AND REINFORCEMENT REQUIRED TO SUPPORT
WALLS OR PARTITIONS ABOVE DOORS.
7. FOR DOOR HARDWARE SETS, REFER TO SHEET A-606. IN ADDITION,
REFER TO SPECIFICATION SECTION FOR ALL DOOR AND HARDWARE
PRODUCTS.
GENERAL DOOR NOTES
8. WHERE INCLUDED, AUTOMATIC DROP SEALS SHOULD BE PROPERLY
ADJUSTED SUCH THAT THE RELEASE BUTTON IS ENGAGED ONCE THE
DOOR IS LATCHED SHUT AND THE SEAL IS PRESSED FIRMLY TO THE
GROUND SO THAT AIR CANNOT PASS UNDERNEATH THE DOOR.
9. THRESHOLDS, FOR DOORS WITH AUTOMATIC DROP SEALS, SHOULD
BE A SMOOTH, HARD, LEVEL SURFACE SO THAT THE DROP SEALS
FORM A UNIFORMLY AIRTIGHT SEAL WHEN ENGAGED.
10. LEVELLING OF THE FLOOR DOORS TO ENSURE THAT SEALS CAN HAVE
EVEN COMPRESSION ALONG THEIR LENGTH AND ANY GAPS ARE
UNIFORM.
11. ALL SEALS SHOULD BE CONTINUOUS WITH NO GAPS OR BREAKS.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
WVA B120
R T
A S
U B
M
IS
S
IO
N /0
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
A u to d e s k D o c s
/A U
S -0
-U
S A
C E
N
Y W
V A
B ld g R e c a p /A
-W V
A R
.r v t
/1
/2
:2
:5
P
M
A-605
D O
O R
S C
H E
D U
L E
P
A N
E L
F R
A M
E T
Y P
E S
D
O O
R H
A R
D W
A R
E S
C H
E D
U L E
W A
T E
R V
L
IE
T A
R S
E N
A L N
Y
N Y
D
IS
T R
IC
T
A R
C A
D
IS
U .S
I N
C
R
O U
T E
S
U
IT
E
C L
IF
T O
N P
A R
K N
Y
E W
R
IG
H T
L L U
B M
C C
A R
T H
Y
E W
R
IG
H T
/0
/2
W D
S F
W D
S D
I D
C -M
R E
C A
P
IT
A L
IZ
A T
IO
N
O F
B U
IL
D
IN
G
B
P R
O J E
C T
N O
W
D
S F
DOOR PANEL TYPES
DOOR FRAME TYPES
DOOR SCHEDULE
MARK FROM TO WIDTH HEIGHT
DOOR PANEL DOOR FRAME
STC MIN
RATING
FIRE
RATING
DOOR
HARDWARE REMARKSTYPE
MAT'L,
FINISH TYPE
MAT'L/FINI
SH
ENTRANCE FLOOR_FF
0EL1 ELEV LOBBY MECH/ELEC 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 1 HR SET 7.1 (M/E RMS) KNURLED HARDWARE, INSUL DOOR
0SH1 ELEV LOBBY OPEN SPACE 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 53
0SH2 HISTORIC LOBBY OPEN SPACE 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 53
0STR03 HISTORIC LOBBY STAIR 03 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6 (STAIRS) PANIC HARDWARE, CR
001A EXTERIOR VESTIBULE 6' - 0" 7' - 0" SEE ELEV SEE
STOREFRONT
SPEC, PT
SEE ELEV SEE
STOREFRONT
SPEC, PT
45 MIN SET 3 EXTERIOR, PANIC
HARDWARE, CR
001B EXTERIOR VESTIBULE 3' - 0" 7' - 0" SEE ELEV SEE
STOREFRONT
SPEC, PT
SEE ELEV SEE
STOREFRONT
SPEC, PT
45 MIN SET 3A EXTERIOR, PANIC
HARDWARE, CR
001C EXTERIOR VESTIBULE 3' - 0" 7' - 0" SEE ELEV SEE
STOREFRONT
SPEC, PT
SEE ELEV SEE
STOREFRONT
SPEC, PT
45 MIN SET 3B EXTERIOR, PANIC
HARDWARE, CR, AUTO
OPERATOR
002A VESTIBULE HISTORIC LOBBY 6' - 0" 7' - 0" EXTG EXTG EXTG REFINISH - SET3.1
002B VESTIBULE HISTORIC LOBBY 3' - 0" 7' - 0" EXTG EXTG EXTG REFINISH - SET 3A.1
002C VESTIBULE HISTORIC LOBBY 3' - 0" 7' - 0" EXTG EXTG EXTG REFINISH - SET 3B.1 AUTO OPERATOR
OME1 OPEN SPACE NEUTRALIZATION
TANK RM
3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 7
01_LEVEL_FF
1EL1 PW STORAGE ELECTRICAL 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 1 HR SET 7.1 (M/E RMS) KNURLED HARDWARE, INSUL DOOR
1EL2 CORRIDOR TRANSFORMER RM 6' - 0" 8' - 0" AA HM,PT 1 HM, PT 25 1 HR SET 10 KNURLED HARDWARE, ASTRAGAL, INSUL DOOR, CR
1JC1 MENS LOCKER ROOM JANITORS CLOSET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 7 (STOREROOM)
1JC2 PW SHOP JANITORS CLOSET 2' - 6" 8' - 0" A HM,PT 1 HM, PT - SET 7 (STOREROOM)
1ME1 PW STORAGE MECHANICAL ROOM 6' - 0" 8' - 0" AA HM,PT 1 HM, PT 25 1 HR SET 8 (M/E RMS) KNURLED HARDWARE, INSULATED DOOR
1ME2 PW STORAGE MECHANICAL ROOM 6' - 0" 7' - 0" AA HM,PT 2 HM, PT 25 1 HR SET 8 (M/E RMS) KNURLED HARDWARE
1OH1 BOX SHOP EXTERIOR 12' - 0" 14' - 9" S PTD, MT-54 INSIDE MTD STL, MT-54 - SET 5 EXTERIOR, INSULATED;
NO GRILLE REQUIRED;
INTERIOR MOUNT
1OH2 BOX SHOP EXTERIOR 12' - 1" 13' - 3" S PTD, MT-54 INSIDE MTD STL, MT-54 - SET 5 EXTERIOR, INSULATED;
NO GRILLE REQUIRED;
INTERIOR MOUNT
1OH3 FIBER SHOP EXTERIOR 8' - 0" 13' - 3" S PTD, MT-54 INSIDE MTD STL, MT-54 - SET 5 EXTERIOR, INSULATED;
NO GRILLE REQUIRED;
INTERIOR MOUNT
1OH4 FIBER SHOP EXTERIOR 12' - 1" 13' - 3" S PTD, MT-54 INSIDE MTD STL, MT-54 - SET 5 EXTERIOR, INSULATED;
NO GRILLE REQUIRED;
INTERIOR MOUNT
1OH7 CORRIDOR EXTERIOR 12' - 1" 13' - 3" S PTD, MT-54 INSIDE MTD STL, MT-54 - SET 5 EXTERIOR, INSULATED;
WITH EXT MOUNTED
GRILLE
1OH8 PW SHOP EXTERIOR 12' - 1" 13' - 3" S PTD, MT-54 INSIDE MTD STL, MT-54 - SET 5 EXTERIOR, INSULATED;
WITH EXT MOUNTED
GRILLE
1OH9 PW SHOP EXTERIOR 12' - 1" 13' - 3" S PTD, MT-54 INSIDE MTD STL, MT-54 - SET 5 EXISTING TO REMAIN -
REPAINT -EXTERIOR,
INSULATED; WITH EXT
MOUNTED GRILLE
1OH10 PW SHOP PW STORAGE 8' - 0" 11' - 0" I PTD INSIDE MTD STL - SET 5 INTERIOR, INSULATED
1OH11 BOX SHOP PW STORAGE 8' - 0" 11' - 0" I PTD INSIDE MTD STL - SET 5 INTERIOR, INSULATED
1OH12 BOX SHOP FIBER SHOP 12' - 1" 13' - 3" S PTD INSIDE MTD STL - SET 5 INTERIOR, INSULATED
1STR01A CORRIDOR STAIR 01 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6 (STAIRS) CR
1STR01B BOX SHOP STAIR 01 3' - 0" 8' - 0" A HM,PT 2 HM, PT 1 HR SET 6 (STAIRS) CONFIRM SIZE WITH
EXISTING MO, CR
1STR01C STAIR 01 EXTERIOR 2' - 10" 7' - 0" C HM,INSUL,
GALV
2 HM,INSUL,
GALV
- SET 1 EXTERIOR, CONFIRM
SIZE WITH EXTG MO, CR
1STR03 CORRIDOR STAIR 03 3' - 0" 8' - 0" A HM,PT 2 HM, PT 1 HR SET 6 (STAIRS) CONFIRM SIZE WITH
EXISTING MO, CR
1STR05A CORRIDOR STAIR 05 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6 (STAIRS) CR
1STR05B STAIR 05 EXTERIOR 3' - 0" 6' - 8" C HM,INSUL,
GALV
2 HM,INSUL,
GALV
- SET 1 EXTERIOR, CONFIRM
SIZE WITH EXTG MO, CR
1TL1 PW STORAGE TELECOM 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 7.1 (M/E RMS)
102 CORRIDOR WOMENS LOCKER
ROOM
3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 49
103 CORRIDOR MENS LOCKER ROOM 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 49
104 CORRIDOR FIRE/WATER SERVICE 6' - 0" 8' - 0" AA HM,PT 1 HM, PT 25 1 HR SET 10 KNURLED HARDWARE
104A CORRIDOR FIRE/WATER SERVICE 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6.1 KNURLED HARDWARE
105 UNASSIGNED EXTERIOR 4' - 0" 7' - 0" A HM,INSUL,
GALV
1 HM,INSUL,
GALV
- SET 1.1 EXTERIOR, CR
106 CORRIDOR BENET CHEM STO 3' - 0" 7' - 0" A HM,PT 1 HM, PT 2HR SET 4.2 KNURLED HARDWARE, CR
108 CORRIDOR FIRE SERVICE RM 6' - 0" 7' - 0" AA HM,PT 2 HM, PT 25 1 HR SET 8 (M/E RMS)
114A FIBER SHOP EXTERIOR 3' - 0" 8' - 0" A HM,INSUL,
GALV
1 HM,INSUL,
GALV
- SET 2 EXTERIOR, CONFIRM
SIZE WITH EXISTING RO,
CR
121A CORRIDOR PW SHOP 3' - 6" 8' - 0" A HM,PT 1 HM, PT - SET 53 (SHOP)
121B CORRIDOR PW SHOP 3' - 4" 8' - 0" A HM,PT 2 HM, PT - SET 53 (SHOP)
121C PW SHOP EXTERIOR 3' - 0" 7' - 0" C HM,INSUL,
GALV
2 HM,INSUL,
GALV
- SET 2 EXTERIOR, CONFIRM
SIZE WITH EXTG MO, CR
121D PW SHOP EXTERIOR 3' - 0" 7' - 0" C HM,INSUL,
GALV
2 HM,INSUL,
GALV
- SET 2 EXTERIOR, CONFIRM
SIZE WITH EXTG MO, CR
121E CORRIDOR PW SHOP 6' - 0" 8' - 0" CC HM,PT 1 HM, PT - SET 53A (SHOP)
122 PW SHOP LEADER OFFICE 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
123 PW SHOP LEADER OFFICE 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
124 PW SHOP LIBRARY 3' - 0" 8' - 0" A HM,PT 1 HM, PT 30 - SET 48 (PASSAGE)
125A PW STORAGE TOOL ROOM 3' - 0" 8' - 0" A HM,PT 1 HM - SET 7 (STOREROOM)
125B PW STORAGE TOOL ROOM 3' - 0" 8' - 0" A HM,PT 1 HM - SET 7 (STOREROOM)
126 PW SHOP TOILET 3' - 0" 8' - 0" A HM,PT 1 HM 25 - SET 13 (TOILET) INSULATED DOOR, UNDERCUT DOOR
127 CORRIDOR MECHANICS 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 52 (OFFICE) INTERIOR, INSULATED
128 CORRIDOR ADMIN 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
129 CORRIDOR SUPERVISOR OFFICE 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
130A CORRIDOR PW STORAGE 3' - 0" 8' - 0" A HM,PT 2 HM, PT - SET 53 (SHOP)
130B PW STORAGE PW SHOP 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 53 (SHOP)
130C CORRIDOR PW STORAGE 6' - 0" 8' - 0" CC HM,PT 1 HM, PT - SET 53A (SHOP)
130D CORRIDOR PW STORAGE 6' - 0" 8' - 0" AA HM,PT 1 HM, PT - SET 53A (SHOP)
141A CORRIDOR BOX SHOP 3' - 6" 8' - 0" A HM,PT 2 HM, PT - SET 4.2 CR
141B BOX SHOP FIBER SHOP 3' - 0" 7' - 0" A HM,PT 1 HM, PT - SET 13.1
141C PW STORAGE BOX SHOP 3' - 0" 7' - 0" C HM,PT 1 HM, PT - SET 4.2 CR
142A BOX SHOP OFFICE 3' - 0" 8' - 0" A HM,PT 2 HM, PT 25 - SET 52 (OFFICE)
DOOR SCHEDULE
MARK FROM TO WIDTH HEIGHT
DOOR PANEL DOOR FRAME
STC MIN
RATING
FIRE
RATING
DOOR
HARDWARE REMARKSTYPE
MAT'L,
FINISH TYPE
MAT'L/FINI
SH
142B FIBER SHOP OFFICE 3' - 0" 7' - 0" C HM,PT 1 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
143 BOX SHOP WOOD TOOL
STORAGE
3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 52.1
144B FIBER SHOP EXTERIOR 3' - 0" 8' - 0" A HM,INSUL,
GALV
1 HM,INSUL,
GALV
- SET 2 EXTERIOR, CONFIRM
SIZE WITH EXTG RO, CR
MEZZANINE_FF
15CL1 CORRIDOR CLOSET 6' - 0" 8' - 0" AA HM,PT 1 HM, PT - SET 14 CLOSET
15JC1 CORRIDOR JANITORS CLOSET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 7 (STOREROOM)
15STR01 CORRIDOR STAIR 03 3' - 0" 8' - 0" A HM,PT 2 HM, PT 1 HR SET 6 (STAIRS) CONFIRM SIZE WITH
EXISTING MO, CR
150 CORRIDOR WELLNESS 3' - 0" 7' - 0" A HM,PT 1 HM, PT 25 - SET 52 (OFFICE)
154 CORRIDOR AC MECHANICS
OFFICE
3' - 0" 8' - 0" A HM,INSUL,
GALV
1 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
155 CORRIDOR ELECTRICIANS OFFICE 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
158 CORRIDOR RADIO ROOM 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 7 (STOREROOM)
02_LEVEL_FF
1' - 5 3/4" 8' - 4 1/16" G
2CL1 OPEN OFFICE CLOSET 6' - 0" 8' - 0" AA HM,PT 1 HM, PT - SET 14 CLOSET
2CL2 CORRIDOR CLOSET 6' - 0" 8' - 0" AA HM,PT 1 HM, PT - SET 14 CLOSET
2EL1 CORRIDOR ELECTRICAL 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 1 HR SET 7.1 (M/E RMS)
2JC1 MAIN LAB JANITORS CLOSET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 7 (STOREROOM) UNDERCUT DOOR
2JC2 CORRIDOR JANITORS CLOSET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 7 (STOREROOM) UNDERCUT DOOR
2ME1 CORRIDOR MECHANICAL ROOM 6' - 0" 8' - 0" AA HM,PT 1 HM, PT 25 1 HR SET 8 (M/E RMS) INSULATED DOOR
2MEEL2 OPEN OFFICE MECH/ELE FOR LAB 6' - 0" 7' - 10 1/2" AA HM,PT 1 HM 30 1 HR SET 8 (M/E RMS) INSULATED DOOR
2OH1 MAIN LAB MATERIAL STAGING 11' - 0" 11' - 0" S PTD INSIDE MTD STL - SET 5 INTERIOR, INSULATED
2OH2 PROCESS PREP. AREA MATERIAL STAGING 11' - 0" 11' - 0" S PTD INSIDE MTD STL - SET 5 INTERIOR, INSULATED
2PU1 MAIN LAB PUMP ROOM #1 QUIET
LAB
3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 53.1 INSULATED DOOR
2PU2 MAIN LAB PUMP ROOM #2 QUIET
LAB
3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 53.1 INSULATED DOOR
2SE1 MAIN LAB SECURITY 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 7
2STR01 CORRIDOR STAIR 01 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6 (STAIRS) CR
2STR03 ELEV CORRIDOR STAIR 03 3' - 4" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6 (STAIRS) CR
2STR05 MAIN LAB STAIR 05 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6 (STAIRS) CR
2TL1 CORRIDOR TELECOM 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 7.1 (M/E RMS)
2TL2 MAIN LAB TELECOM 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 7.1 (M/E RMS)
2TL3 MECH/ELE FOR LAB TELECOM 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 1 HR SET 7.1 (M/E RMS)
202A CORRIDOR TOILET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 13 TOILET UNDERCUT DOOR
202B CORRIDOR TOILET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 13 TOILET UNDERCUT DOOR
202C CORRIDOR TOILET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 13 TOILET UNDERCUT DOOR
202D CORRIDOR TOILET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 13 TOILET UNDERCUT DOOR
202E CORRIDOR TOILET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 13 TOILET UNDERCUT DOOR
202F CORRIDOR TOILET 3' - 0" 8' - 0" A HM,PT 1 HM, PT SET 13 TOILET UNDERCUT DOOR
203 ELEV CORRIDOR WELLNESS 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
205 BRIDGE PANTRY 3' - 8" 7' - 0" A HM,INSUL,
GALV
2 HM,INSUL,
GALV
2 HR SET 4 AT BRIDGE EXTERIOR, CR,
INSULATED
207 ELEV CORRIDOR CONFERENCE 3' - 0" 8' - 0" A HM,PT 3 HM, PT 30 - SET 52 (OFFICE) INSULATED DOOR
210 CORRIDOR OFFICE 3' - 0" 8' - 0" A HM,PT 3 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
211 CORRIDOR OFFICE 3' - 0" 8' - 0" A HM,PT 3 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
212 CORRIDOR OFFICE 3' - 0" 8' - 0" A HM,PT 3 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
213 CORRIDOR SUPERVISOR OFFICE 3' - 0" 8' - 0" A HM,PT 3 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
214 CORRIDOR OFFICE 3' - 0" 8' - 0" A HM,PT 3 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
215 CORRIDOR COMPUTATIONAL
SPACE
3' - 0" 8' - 0" B HM,PT 1 HM, PT 25 - SET 52 (OFFICE) INSULATED DOOR
216 CORRIDOR MEETING 3' - 0" 8' - 0" A HM,PT 1 HM, PT 30 - SET 52 (OFFICE) INSULATED DOOR
217A ELECTRICAL ROOM
FOR LAB
FIRE SERVICE RM 6' - 0" 7' - 10 1/2" AA HM,PT 1 HM, PT 1 HR SET 53.2
217B ELECTRICAL ROOM
FOR LAB
FIRE SERVICE RM 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 53.2
220A ELEV CORRIDOR MAIN LAB 6' - 0" 8' - 0" CC HM,PT 1 HM, PT 1 HR SET 8 CR
221 MAIN LAB NMR LAB 2' - 11 3/4" 8' - 4 1/16" G PER MANUF PER MANUF PER MANUF 25 - SET 51 (SEE GLASS
WALL SYSTEM SPEC)
GLASS WALL SYSTEM
DOOR WITH CLOSER,
SURROUND SEALS, SEAL
DROP AT SILL
222A1 BSL 2 AIR LOCK BSL 2 LAB 3' - 6" 8' - 0" B SS 1 SS - SET 53.1 AIRTIGHT
222A2 MAIN LAB BSL 2 AIR LOCK 3' - 6" 8' - 0" B SS 1 SS - SET 53.1 AIRTIGHT
223 MAIN LAB QUIET LAB 4' - 11 3/4" 8' - 4 1/16" GG PER MANUF PER MANUF PER MANUF 25 - SET 9 (SEE GLASS
WALL SYSTEM SPEC)
GLASS WALL SYSTEM
DOOR WITH CLOSER,
SURROUND SEALS, SEAL
DROP AT SILL,
MAGNETIC STREGAL
224A ELEV CORRIDOR PPE 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 48 (PASSAGE)
224B MAIN LAB PPE 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 1 HR SET 4.1 CR
226 CORRIDOR PROCESS LAB 3' - 0" 8' - 0" C HM,PT 1 HM, PT 1 HR SET 7.1
227A PROCESS LAB CHEMICAL STORAGE 3' - 0" 8' - 0" B HM,PT 1 HM, PT 1 HR SET 53.2
227B PROCESS LAB CHEMICAL STORAGE 3' - 0" 8' - 0" B HM,PT 1 HM, PT 1 HR SET 53.2
228A PROCESS LAB PPE 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 4.1 CR
228B CORRIDOR PPE 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 48
230A MATERIAL STORAGE STORAGE 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 7.1
231A ELEV CORRIDOR MATERIAL STAGING 6' - 0" 8' - 0" AA HM,PT 1 HM, PT 1 HR SET 30 CR
231B PROCESS PREP. AREA MATERIAL STAGING 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 53
231C MAIN LAB MATERIAL STAGING 6' - 0" 8' - 0" AA HM,PT 1 HM, PT 1 HR SET 30.1
03_LEVEL_FF
3C01 STORAGE ELEV CONTROL RM 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 7.1
3EL1 ELEV CORRIDOR ELECTRICAL 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 1 HR SET 7.1 (M/E RMS)
3ME3 STORAGE MECHANICAL 6' - 0" 8' - 0" AA HM,PT 1 HM, PT 30 1 HR SET 8 (M/E RMS) INSULATED DOOR
3STR01 STORAGE STAIR1 3' - 0" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6 (STAIRS) CR
3STR03 ELEV CORRIDOR STAIR 03 3' - 4" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6 (STAIRS) CR
3STR05 STORAGE STAIR 05 2' - 8" 8' - 0" A HM,PT 1 HM, PT 1 HR SET 6 (STAIRS) CR
3TL1 TELECOM STORAGE 3' - 0" 8' - 0" A HM,PT 1 HM, PT - EXISTING HARDWARE
301 STORAGE TOILET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 13 (TOILET)
302 STORAGE TOILET 3' - 0" 8' - 0" A HM,PT 1 HM, PT - SET 13 (TOILET)
303 STORAGE AREA 2
NORTH
FIRE SERVICE RM 3' - 0" 8' - 0" A HM,PT 1 HM, PT 25 - SET 7.1 (M/E RMS) INSULATED DOOR
304 STORAGE EXTERIOR ROOF 3' - 6" 3' - 10" A HM,PT 1 HM,INSUL,
GALV
SET 7.2 EXTERIOR, INSULTATED
DOOR, CONFIRM SIZE
WITH EXISTING RO
ROOF_BTM OF SLAB
4EL1 FREIGHT ELEV MACH
RM
EXTERIOR ROOF 3' - 4" 7' - 0" C HM,INSUL,
GALV
2 HM,INSUL,
GALV
SET 7.2 EXTERIOR, INSULTATED
DOOR, CONFIRM SIZE
WITH EXISTING RO
4STR03 STAIR 3 EXTERIOR ROOF 3' - 0" 7' - 0" C HM,INSUL,
GALV
2 HM,INSUL,
GALV
SET 1 EXTERIOR, INSULATED
DOOR, CONFIRM SIZE
WITH EXISTING RO, CR
NOTE: GLAZING TO BE INSULATED LAMINATED AT ALL EXTERIOR DOORS
NOT U
SED
NOT U
SED
2 SWEEP
1 SET WEATHER STRIP
1 THRESHOLD
2 SURFACE CLOSER
2 CYLINDER, MORTISE/RIM
002A 2 CONCEALED VERT ROD EXIT DEVICES, NIGHTLATCH 2. ALWAYS FREE EGRESS.
3.1 INTERIOR PAIR EXISTING STOREFRONT
ENTRANCE, NOT RATED
VERTICAL ROD EXIT DEVICES, CLOSER 6 STEEL PIVOTS (EXISTING) 1. ALL EXTERIOR DOORS SHALL CONFORM TO UFC 4-010-01 .
1 POWER SUPPLY
2 DOOR POSITION SWITCH
1 ELECTRIC LYNX HARNESS
2 SWEEP
2 RAIN GUARD
1 SET WEATHER STRIP BY DOOR MFGR.
1 THRESHOLD
2 SURFACE CLOSER 4. ALWAYS FREE EGRESS.
2 CYLINDER, MORTISE/RIM
2 CONCEALED VERT ROD EXIT DEVICES, NIGHTLATCH 3. PROGRAM ACTUATOR SWITCHES AS DIRECTED BY SECURITY FOR
ACCESS CONTROL TIMES OR BY CARD READER ACTIVATION.
001A CR 1 ELECTRIC POWER TRANSFER 2. ACCESS BY AUTHORIZED CARD CREDENTIAL OR MANUAL KEY.
3 EXTERIOR PAIR FIRE RATED ENTRANCE VERTICAL ROD EXIT DEVICES, LATCH RETRACT,
CLOSER
6 STEEL PIVOTS 2 FIRE/SMOKE GASKETING 1. ALL EXTERIOR DOORS SHALL CONFORM TO UFC 4-010-01 .
1 PROX READER/KEYPAD PROVIDED BY SECURITY CONTRACTOR
1 POWER SUPPLY
1 DOOR POSITION SWITCH
1 ELECTRIC LYNX HARNESS
1SWEEP
1 RAIN GUARD
1 SET WEATHER STRIP
144B CR 1 THRESHOLD 4. ALWAYS FREE EGRESS.
121D CR 1 SURFACE CLOSER
121C CR 1 CYLINDRICAL LEVER LOCKSET (STOREROOM FUNCTION), FAIL SAFE 3. PROGRAM ACTUATOR SWITCHES AS DIRECTED BY SECURITY FOR
ACCESS CONTROL TIMES OR BY CARD READER ACTIVATION.
114A CR 1 ELECTRIC STRIKE 2. ACCESS BY AUTHORIZED CARD CREDENTIAL OR MANUAL KEY.
2 EXTERIOR SINGLE PW & BOX SHOP STOREOOM FUNCTION, ELECTRIC LATCH, PIR,
CARD READER, CLOSER
1 CONTINUOUS HINGE 1. ALL EXTERIOR DOORS SHALL CONFORM TO UFC 4-010-01 .
1 OVERHEAD CONCEALED DOOR STOP
1 PROX READER/KEYPAD PROVIDED BY SECURITY CONTRACTOR
1 POWER SUPPLY
1 DOOR POSITION SWITCH
1 ELECTRIC LYNX HARNESS
1 SWEEP
1 RAIN GUARD
1 SET WEATHER STRIP
1 THRESHOLD
1 SURFACE CLOSER
1 CYLINDER, BEST COMPATABLE
1 CYLINDRICAL LEVER LOCKSET (STOREROOM FUNCTION)
105 CR 1 ELECTRIC STRIKE/CYLINDRICAL LOCK TYPE 2. ACCESS BY AUTHORIZED CARD CREDENTIAL OR MANUAL KEY BOTH
SIDES.
1.1 EXTERIOR SINGLE UNASSIGNED/STORAGE DPS BOLT MONITOR, CARD READER, CLOSER 1 CONTINUOUS HINGE 1. ALL EXTERIOR DOORS SHALL CONFORM TO UFC 4-010-01 .
1 PIR PROVIDED BY SECURITY CONTRACTOR
1 PROX READER/KEYPAD PROVIDED BY SECURITY CONTRACTOR
1 POWER SUPPLY
1 DOOR POSITION SWITCH (DPS)
1 ELECTRIC LYNX HARNESS
1 SWEEP/DOOR BOTTOM
1 RAIN GUARD 7. CREDENTIAL USED TO ACCESS ROOF IS THE SAME AS THAT USED TO
EGRESS FROM ROOF
1 SET WEATHER STRIPPING 6. ACCESS BY AUTHORIZED CARD OR MANUAL KEY
1 THRESHOLD 5. PIR
1 SURFACE CLOSER
4STR03 FR, CR 1 CYLINDER, MORTISE/RIM 4. COMMUNICATION ALARM FOR DOOR 4ST3 IS REQUIRED IN THE EVENT OF
ACCIDENTIALLY BEING LOCKED ON ROOF.
1STR05B FR, CR 1 RIM EXIT DEVICE, NIGHT LATCH LBM 3. ALWAYS FREE EGRESS.
1STR01C FR, CR 1 ELECTRIC STRIKE/RIM EXIT DEVICE TYPE 2. LATCH BOLT MONITORING FOR INTRUSION SYSTEM MONITORING.
1 EXTERIOR SINGLE STAIR EGRESS DPS BOLT MONITOR, CARD READER, CLOSER 1 CONTINUOUS HINGE 1. ALL EXTERIOR DOORS SHALL CONFORM TO UFC 4-010-01 .
SET # LOCATION LEAF TYPE USE DESCRIPTION HARDWARE NOTES
DOOR HARDWARE SCHEDULE
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M D
T
/1
/2
| Sheets |
| A-102 - SECOND FLOOR PLAN |
| A-110 - ENTRY LEVEL REFLECTED CEILING PLAN |
| A-605 - DOOR SCHEDULE, PANEL & FRAME TYPES, DOOR HARDWARE SCHEDULE |
| A-606 - DOOR HARDWARE SCHEDULE |
File details come from the government source that posted it. Updated .