This document is a Request for Proposal (RFP) for the Repair of Building 120, a 102,000 square foot multi-use building at the Watervliet Arsenal in New York. The project will consolidate a wood shop and general facility maintenance on the ground level, construct a new modern lab facility on the second level, and provide new office space on the third level. The solicitation is a single-step "Best Value Trade Off" with a firm fixed price contract to be awarded to the responsible firm that provides the best overall value to the Government. The magnitude of the project is between $25M-$100M. The Department of the Army Corps of Engineers, Engineering District New York is the procuring agency. This acquisition will involve a Project Labor Agreement.
View the file
Other files
Show 40 more
Latest 50 of 59 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURAL GENERAL NOTES
1. WORK SHALL COMPLY WITH THE UNITED FACILITIES CRITERIA (UFC) 1-200-01 DOD BUILDING CODE, WITH
CHANGE 2 AND BY REFERENCE, UFC 3-301-01 STRUCTURAL ENGINEERING, WITH CHANGE 1.
2. THE CONTRACTOR SHALL COORDINATE SPECIAL INSPECTIONS WITH OWNER. SPECIAL INSPECTIONS TO
BE PERFORMED IN ACCORDANCE WITH SPECIFICATIONS "01 45 35 SPECIAL INSPECTIONS".
3. SECTIONS AND DETAILS SHOWN ON DRAWINGS ARE TYPICAL. USE SIMILAR CONSTRUCTION AT
LOCATIONS NOT SPECIFICALLY DETAILED. DO NOT SCALE DRAWINGS.
4. EXAMINE AND COMPARE STRUCTURAL DRAWINGS WITH ARCHITECTURAL, MECHANICAL, PLUMBING, SITE, ELECTRICAL, AND PROCESS DRAWINGS. VERIFY LOCATIONS AND DIMENSIONS OF CHASES, INSERTS, OPENINGS, SLEEVES, DEPRESSIONS, AND OTHER PROJECT REQUIREMENTS NOT SHOWN ON THE
STRUCTURAL DRAWINGS.
5. VERIFY LOCATION OF EXISTING UNDERGROUND SITE UTILITIES PRIOR TO THE START OF WORK AND COORDINATE LOCATION WITH STRUCTURAL DRAWINGS. NOTIFY THE ENGINEER OF ANY CONFLICTS IN
WRITING. DO NOT PROCEED WITH AFFECTED WORK UNTIL CONFLICTS HAVE BEEN RESOLVED.
6. ADEQUATE TEMPORARY BRACING OF CONSTRUCTION ELEMENTS SHALL BE PROVIDED FOR
FOUNDATIONS, ABOVE GRADE WALLS, STRUCTURAL STEEL, AND OTHER STRUCTURAL SYSTEMS FOR
WIND AND/OR CONSTRUCTION LOADS. BRACING SHALL BE MAINTAINED AT ALL TIMES DURING
CONSTRUCTION OPERATIONS PRIOR TO STRUCTURAL ELEMENTS REACHING THEIR SPECIFIED DESIGN
STRENGTH AND/OR REACHING THEIR COMPLETED FORM AS SHOWN ON THE CONTRACT DRAWINGS.
DESIGN AND MAINTENANCE OF SAID BRACING SHALL BE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
7. VERIFY IN FIELD EXISTING CONDITIONS AND DIMENSIONS PRIOR TO THE START OF WORK. NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES IN WRITING. DO NOT PROCEED WITH AFFECTED WORK
UNTIL DISCREPANCIES HAVE BEEN RESOLVED.
8. PRIOR TO EXCAVATION ADJACENT TO EXISTING TO OR WITHIN STRUCTURES, DOCUMENT THE CONDITION OF THE EXISTING STRUCTURES INCLUDING PHOTOGRAPHS, LOCATIONS, AND DETAILED DESCRIPTIONS OF NOTED EXISTING STRUCTURAL DISTRESS OR OTHER STRUCTURAL IRREGULARITIES.
SUBMIT DOCUMENTATION OF EXISTING DISTRESS, FOR RECORD PURPOSES, PRIOR TO PROCEEDING
WITH EXCAVATION WORK.
9. DIMENSIONS DEPENDENT ON EQUIPMENT SELECTION AND APPROVAL SHALL BE COORDINATED BY THE
CONTRACTOR PRIOR TO SUBMITTING STRUCTURAL SHOP DRAWINGS FOR REVIEW.
STRUCTURAL FOUNDATION NOTES
1. FOUNDATION DESIGN IS BASED ON WATERVLIET ARSENAL WAREHOUSE FOUNDATION PLAN (PLAN NUMBER 6529-162), DATED APRIL 8, 1941 AND ON GEOTECHNICAL ENGINEERING REPORT, DATED SEPTEMBER 10, 2019, BY TERRACON CONSULTANTS-NY, INC. REFER TO STRUCTURAL DESIGN CRITERIA
FOR ADDITIONAL INFORMATION.
2. GROUND WATER LEVELS SHALL BE LOWERED TO A MINIMUM OF 3 FEET BELOW MAXIMUM EXCAVATION DEPTH. LOWERING OF GROUND WATER SHALL BE CONTINUOUS DURING CONSTRUCTION AND SHALL BE MAINTAINED UNTIL BACKFILL IS PLACED TO AT LEAST 2 FEET ABOVE THE HIGHEST GROUND WATER ELEVATION. DESIGN AND MAINTENANCE OF SYSTEM TO LOWER GROUND WATER SHALL BE THE SOLE
RESPONSIBILITY OF THE CONTRACTOR.
3. FOUNDATIONS OR SLABS SHALL NOT BE PLACED IN WATER, OR SATURATED SUBGRADES, NOR ON
FROZEN SUBGRADES. IN-PLACE FOUNDATIONS AND SLABS SHALL BE PROTECTED FROM FROST
PENETRATION UNTIL FOUNDATIONS ARE BACKFILLED AND/OR PROJECT IS COMPLETE.
4. PLACE FOUNDATIONS AND SLABS-ON-GRADE ON A MINIMUM 6 INCH THICKNESS OF ASTM NO. 57 CRUSHED STONE SUBBASE, UNLESS OTHERWISE NOTED. COMPACT EXISTING SUBGRADE PRIOR TO
PLACEMENT OF FOUNDATIONS.
5. COMPACTED STRUCTURAL BACKFILL: STRUCTURAL BACKFILL SHALL BE USED FOR BACKFILL BEHIND
PERMANENT WALLS AND WHEREVER LOAD-BEARING CAPABILITY IS REQUIRED INCLUDING UNDER
STRUCTURES. STRUCTURAL FILL SHALL CONSIST OF WELL-GRADED SAND, GRAVEL, CRUSHED ROCK, RECYCLED CONCRETE AGGREGATE, OR A MIXTURE OF THESE CONTAINING NO ORGANIC MATTER OR DELETERIOUS MATERIALS, WITH LIMITING MAXIMUM PARTICLE SIZE TO 1 INCH, AND LIMITING FINES CONTENT TO LESS THAN 5% PASSING THE NO. 200 SIEVE. STRUCTURAL BACKFILL SHALL BE COMPACTED TO NOT LESS THAN 95% OF MAXIMUM DENSITY ACCORDING TO ASTM D1557. PLACE BACKFILL AND FILL
MATERIALS IN LAYERS NOT MORE THAN 8 INCHES IN LOOSE DEPTH.
6. DO NOT BACKFILL AGAINST BELOW-GRADE BASEMENT WALLS UNTIL FLOOR SLAB SUPPORTING TOP OF WALL IS COMPLETED OR PROVIDE TEMPORARY SUPPORT FOR TOP OF WALL UNTIL FLOOR SLAB IS IN
PLACE AND HAS REACHED DESIGN STRENGTH.
7. TOPSOIL, ORGANIC MATERIAL, AND ANY NATURAL OR MAN-MADE DEBRIS SHALL BE STRIPPED FROM THE SITE TO THE DEPTHS REQUIRED OR NOTED. THESE AND OTHER DELETERIOUS MATERIAL SHALL NOT BE
USED AS BACKFILL UNDER ANY STRUCTURAL AREA AND SHALL BE REMOVED FROM THE SITE.
8. UNSUITABLE SUBGRADE, IF ENCOUNTERED, WILL BE UNDERCUT AND REPLACED WITH LEAN CONCRETE, CONTROLLED LOW-STRENGTH MATERIAL, OR SELECT GRANULAR MATERIAL AS ORDERED BY THE
GEOTECHNICAL ENGINEER.
9. THE CONTRACTOR SHALL PROVIDE STABLE SIDES AND BOTTOM OF EXCAVATION DURING
CONSTRUCTION BY SHORES, SLOPES, OR BENCHED SIDES. THE DESIGN AND INSTALLATION OF THE EXCAVATION BRACING SHALL BE IN ACCORDANCE WITH OSHA SHORING PRACTICES AND BE THE SOLE
RESPONSIBILITY OF THE CONTRACTOR.
10. REPLACE VAPOR BARRIERS BENEATH SLABS-ON-GRADE WHERE DEMOLITION CAUSES EXISTING VAPOR
BARRIERS TO BE PUNCTURED OR REMOVED. SEAMS IN THE VAPOR BARRIER SHALL BE SEALED.
LOCATIONS WHERE THE VAPOR BARRIER COMES INTO CONTACT WITH FOUNDATIONS, CAISSONS, OR OTHER PIPE/CONDUIT PENETRATIONS SHALL BE SEALED. EXTERIOR EDGES OF VAPOR BARRIER SHALL
OVERLAP VERTICAL FACE OF CONCRETE FOUNDATION ELEMENTS A MINIMUM OF 6 INCHES. AT
LOCATIONS WHERE VAPOR BARRIER IS PROVIDED, COMPACT UNDERLYING SUBBASE WITH A MINIMUM
OF FOUR PASSES OF LOW-GROUND PRESSURE OR HAND-OPERATED VIBRATORY COMPACTION
EQUIPMENT TO PROTECT UNDERLYING VAPOR BARRIER FROM DAMAGE. INSTALL VAPOR BARRIER
ABOVE THE UNDERLYING SUBBASE AND PROVIDE 2" MINIMUM BLOTTER LAYER OF SAND OR STONE DUST
ABOVE VAPOR BARRIER.
STRUCTURAL CONCRETE NOTES
1. CONCRETE WORK SHALL CONFORM TO REQUIREMENTS OF UFC 3-301-01 AND BY REFERENCE, ACI 301, "SPECIFICATIONS FOR STRUCTURAL CONCRETE" AND ACI 318, "BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE."
2. THE CONCRETE MANUFACTURER SHALL FURNISH A BATCH DELIVERY TICKET TO THE PURCHASER AND ENGINEER OF RECORD FOR EACH BATCH DELIVERED TO THE SITE IN ACCORDANCE WITH ASTM C94.
3. CONTRACTOR SHALL SUBMIT REQUIRED SUBMITTALS TO THE ENGINEER OF RECORD AS OUTLINED IN
ACI 301 PRIOR TO CONCRETE MANUFACTURING.
4. PORTLAND CEMENT USED FOR CONCRETE WORK SHALL COMPLY WITH ASTM C-150 FOR TYPE I/II
CEMENT.
5. NORMAL WEIGHT CONCRETE SHALL CONTAIN FINE AND COARSE AGGREGATES COMPLYING WITH ASTM C-33. THE MAXIMUM SIZE OF COARSE AGGREGATES SHALL BE OF SIZES SUITABLE FOR PLACEMENT IN
STRUCTURAL ELEMENTS CONSIDERING THEIR SIZE AND REINFORCEMENT CONFIGURATION.
6. CONCRETE PLACED UNDER COLD WEATHER CONDITIONS SHALL CONFORM WITH ALL REQUIREMENTS OF ACI 306, "STANDARD SPECIFICATION FOR COLD WEATHER CONCRETING". CONCRETE THAT MAY BE
EXPOSED TO SUBSEQUENT MOISTURE AND FREEZING CONDITIONS PRIOR TO REACHING DESIGN
COMPRESSIVE STRENGTH OR EXTERIOR CONCRETE WORK EXPOSED TO FREEZE / THAW CYCLING SHALL BE AIR-ENTRAINED TO 6% AIR CONTENT. HOWEVER, SLAB FLATWORK TO RECEIVE A HARD-TROWEL
FINISH SHALL NOT BE AIR ENTRAINED.
7. CONCRETE PLACED UNDER HOT WEATHER CONDITIONS SHALL CONFORM TO ALL REQUIREMENTS OF ACI
305.1, "SPECIFICATION FOR HOT WEATHER CONCRETING."
8. CONSTRUCTION / CONTRACTION JOINTS SHOWN ON THE DRAWINGS ARE MANDATORY. OMISSIONS, ADDITIONS, OR CHANGES SHALL NOT BE MADE EXCEPT WITH THE SUBMITTAL OF A WRITTEN REQUEST, TOGETHER WITH DRAWINGS SHOWING PROPOSED LOCATION OF CONSTRUCTION AND CONTRACTION
JOINTS AND CONCRETE PLACEMENT SEQUENCING, FOR APPROVAL BY THE ENGINEER OF RECORD
PRIOR TO THE PREPARATION OF THE REINFORCEMENT SHOP DRAWINGS AND PLACEMENT OF
CONCRETE.
9. PLACE CONCRETE WITHOUT HORIZONTAL CONSTRUCTION JOINTS EXCEPT WHERE SHOWN OR NOTED.
FOLLOW TYPICAL DETAIL GUIDANCE FOR LOCATING VERTICAL CONSTRUCTION JOINTS.
10. AT CONSTRUCTION JOINTS, PROVIDE DOWELS AND 1/4" ROUGHENED SURFACE WITH BONDING AGENT.
ALSO PROVIDE A TENSION CLASS "B" LAP OF REINFORCING. USE ROUGHENED JOINT WHERE INDICATED
ON THE DRAWING.
11. CONCRETE SLABS-ON-GRADE AND CONCRETE PLACED ON STEEL DECK, SHALL BE PLACED SO THAT THE SLAB THICKNESS IS AT NO POINT LESS THAN THAT INDICATED ON THE CONTRACT DRAWINGS. ADJUST
SUBGRADE ELEVATIONS TO ACCOUNT FOR SLOPED SLAB-ON-GRADE SURFACES.
12. CHAMFER EXPOSED CORNERS OF CONCRETE 3/4 INCH.
13. CAST INTO CONCRETE ACCESSORIES REQUIRED BY ARCHITECTURAL FINISHES, MECHANICAL
EQUIPMENT, AND ELEVATOR EQUIPMENT. COORDINATE LOCATION AND QUANTITY WITH
ARCHITECTURAL, MECHANICAL, AND ELEVATOR DRAWINGS.
14. ADHESIVE ANCHORS SHALL NOT BE INSTALLED PRIOR TO CONCRETE HAVING REACHED A MINIMUM AGE OF 21 DAYS AND fc' = 2,500 PSI, VERIFIED THROUGH COMPRESSIVE STRENGTH TESTING.
15. POST-INSTALLED ADHESIVE ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND THE APPLICABLE ICC-ES REPORT FOR
THE ANCHOR SYSTEM.
A. ANCHORS SHALL BE INSTALLED BY QUALIFIED PERSONNEL THAT ARE TRAINED TO INSTALL ADHESIVE ANCHORS. INSTALLERS SHALL BE CERTIFIED BY AN APPLICABLE CERTIFICATION PROGRAM WITHIN THE PAST FIVE YEARS. CERTIFICATION SHALL INCLUDE WRITTEN AND PERFORMANCE TESTS IN
ACCORDANCE WITH THE ACI/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM, OR
EQUIVALENT.
B. CONTINUOUS MONITORING OF INSTALLATION SHALL BE PERFORMED AS PART OF SPECIAL
INSPECTIONS.
16. CURING OF CONCRETE SHALL COMMENCE AS SOON AS FREE WATER HAS DISAPPEARED FROM
CONCRETE SURFACE AFTER PLACING AND FINISHING. CURING MATERIALS AND PROCEDURES ARE AS
FOLLOWS:
A. SLABS/MATS: COVER CONCRETE SURFACES WITH MOISTURE-RETAINING COVER MEETING ASTM C171, EITHER POLYETHYLENE FILM OR WHITE BURLAP-POLYETHYLENE SHEET. PLACE IN WIDEST
PRACTICAL WIDTH WITH SIDES AND ENDS LAPPED A MINIMUM OF 3 INCHES AND SEALED BY
WATERPROOF TAPE OR ADHESIVE. IMMEDIATELY REPAIR ANY HOLES OR TEARS DURING CURING
PERIOD USING COVER MATERIAL AND WATERPROOF TAPE. KEEP CONTINUOUSLY WET FOR NOT LESS
THAN 7 DAYS.
17. CONCRETE SHALL BE NORMAL WEIGHT CONCRETE WITH MIXES DESIGNED TO MEET THE FOLLOWING
CRITERIA:
MIN STRENGTH MAX TOTAL
@28 DAYS W/Cm AIR CONTENT MAX EXPOSURE
ITEM (fc') (PSI) RATIO (+ / - 1%) SLUMP CLASSES
A. INTERIOR CONCRETE,
INCLUDING WALLS & PIERS 4500 .45 1% 4" F0,S0,W1,C0
UON
B. EXTERIOR CONCRETE,
UON 5000 .40 6% 4" F3,S0,W1,C2
STRUCTURAL REINFORCING NOTES
1. REINFORCEMENT WORK OF DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE," ACI SP-66 "ACI DETAILING MANUAL," "CRSI MANUAL OF STANDARD PRACTICE," AND AWS D1.4 "STRUCTURAL WELDING CODE - REINFORCING
STEEL."
2. STEEL REINFORCEMENT, UNLESS NOTED OTHERWISE, SHALL CONFORM TO THE FOLLOWING:
A. BARS, TIES AND STIRRUPS: ASTM A615 GRADE 60 (fy = 60 KSI) B. REINFORCING TO BE WELDED SHALL CONFORM TO ASTM A706 (fy = 60 KSI) OR MILL TEST REPORTS
SHALL BE SUBMITTED SHOWING CARBON EQUIVALENT.
3. MINIMUM CONCRETE PROTECTIVE COVER FOR REINFORCEMENT OF NON-ENVIRONMENTAL
ENGINEERING CONCRETE SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED:
A. CONCRETE CAST AGAINST AND PERMANENTLY IN CONTACT WITH GROUND: 3.0"
B. CONCRETE EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
• #6 THROUGH #18 BARS: 2.0"
• #5 BARS AND SMALLER: 1.5"
C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
a. SLABS, JOISTS, AND WALLS:
• #14 AND #18 BARS: 1.5"
• #11 BARS AND SMALLER: 0.75"
b. BEAMS, COLUMNS, PEDESTALS, AND TENSION TIES:
• PRIMARY REINFORCEMENT, STIRRUPS, TIES, SPIRALS, AND HOOPS: 1.5"
4. WHERE CONTINUOUS REINFORCEMENT IS CALLED FOR, REINFORCEMENT SHALL BE EXTENDED
CONTINUOUSLY AROUND CORNERS AND LAPPED AT NECESSARY SPLICES OR HOOKED AT
DISCONTINUOUS ENDS.
5. LAPS SHALL BE CLASS "B" TENSION LAP SPLICES, UNLESS NOTED OTHERWISE.
6. EXTEND DOWELS TO THE 1/4-POINT OF SLAB SPAN, UNLESS OTHERWISE NOTED.
7. WHERE REINFORCEMENT IS SHOWN IN SECTION, REINFORCEMENT IS CONSIDERED TYPICAL WHEREVER
THE SECTION APPLIES.
8. WHERE THERE IS A CONFLICT BETWEEN LOCATION OF COLUMN VERTICAL BARS AND BEAM HORIZONTAL
BARS, THE COLUMN BARS SHALL REMAIN IN THEIR DESIGNATED POSITIONS AND BEAM BAR LOCATIONS
SHALL BE ADJUSTED.
9. REINFORCEMENT SHALL BE CONTINUOUS THROUGH CONSTRUCTION JOINTS UNLESS OTHERWISE
SHOWN.
10. COLUMN DOWELS SHALL BE SET AND POSITIONED SO AS TO BE ENCLOSED BY THE COLUMN TIES.
11. PROVIDE DOWELS FOR FOUNDATION TO MATCH BAR SIZE AND NUMBER OF REINFORCEMENT IN THE
SUPPORTED ELEMENT, UNLESS OTHERWISE NOTED. PROVIDE A CLASS "B" TENSION LAP SPLICE
BETWEEN THE DOWEL AND MAIN REINFORCEMENT OF SUPPORTED ELEMENT, UNLESS OTHERWISE
NOTED.
12. REINFORCEMENT SHALL NOT BE TACK WELDED OR HEATED FOR BENDING.
13. INSTALLATION OF REINFORCEMENT SHALL BE COMPLETED AT LEAST 24 HOURS PRIOR TO THE
SCHEDULED CONCRETE PLACEMENT. NOTIFY ENGINEER OF RECORD AND INSPECTOR OF COMPLETION
AT LEAST 24 HOURS PRIOR TO THE SCHEDULED COMPLETION OF THE INSTALLATION OF
REINFORCEMENT.
STRUCTURAL STEEL NOTES
1. FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH AISC 360, "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS," AND AISC 303, "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS
AND BRIDGES."
2. STEEL MEMBERS HAVE BEEN DESIGNED UTILIZING ALLOWABLE STRESS DESIGN (ASD) METHODS AS
PRESCRIBED BY AISC.
3. STRUCTURAL STEEL SHALL BE DETAILED IN ACCORDANCE WITH "DETAILING FOR STEEL CONSTRUCTION
(AISC)" AND WHERE REQUIRED, DESIGNED IN ACCORDANCE WITH CITED REFERENCES.
4. STRUCTURAL STEEL AND ACCESSORIES SHALL BE NEW AND CONFORM TO:
A. UNLESS OTHERWISE NOTED: ASTM A992 (Fy = 50 KSI)
B. HOLLOW STRUCTURAL SECTIONS:
• ROUND: ASTM A500 GRADE C (Fy = 46 KSI)
• SQUARE OR RECTANGULAR: ASTM A500 GRADE C (Fy = 50 KSI)
C. MISC STRUCTURAL SHAPES AND CONNECTIONS: ASTM A36 (Fy = 36 KSI) D. ANCHOR BOLTS: ASTM F1554 GRADE 55 (Fy = 55 KSI) E. HIGH STRENGTH BOLTS: ASTM F3125 GRADE A325-N (Fy = 120 KSI)
5. WELDING SHALL CONFORM TO THE REQUIREMENTS OF AWS D1.1, AND SHALL BE PERFORMED BY
APPROVED, CERTIFIED PERSONS.
6. WELDED CONNECTIONS SHALL UTILIZE E70XX ELECTRODES.
7. WELDS SHALL DEVELOP FULL STRENGTH OF THE MATERIALS BEING WELDED, UNLESS OTHERWISE
NOTED, EXCEPT THAT FILLET WELDS SHALL BE A MINIMUM OF 1/4", UNLESS OTHERWISE NOTED.
8. ANCHOR BOLTS, LEVELING PLATES, OR BEARING PLATES SHALL BE LOCATED AND BUILT INTO
CONNECTING WORK, PRESET BY TEMPLATES, AND SET IN FULL BEDS OF NON-SHRINK GROUT.
9. PRINCIPAL STRUCTURAL BOLTED CONNECTIONS (BEAM-BEAM, BEAM-GIRDER, BEAM OR GIRDER TO
COLUMN) SHALL BE MADE USING MINIMUM 3/4" DIAMETER ASTM F3125 GRADE A325 BOLTS IN BEARING
CONNECTIONS.
10. A MINIMUM OF TWO (2) BOLTS SHALL BE UTILIZED AT CONNECTIONS.
11. BOLTS SHALL BE INSTALLED SNUG TIGHT AND PRETENSIONED BY TURN-OF-NUT PRETENSIONING IN
ACCORDANCE WITH RCSC.
12. ENDS OF COLUMNS AT SPLICES AND AT OTHER BEARING CONNECTIONS SHALL BE "FINISHED TO BEAR"
TO COMPLETE TRUE BEARING.
13. PROVIDE STIFFENERS "FINISHED TO BEAR" UNDER LOAD CONCENTRATIONS ON SUPPORTING MEMBERS, OVER COLUMNS, AND WHERE SHOWN ON DRAWINGS.
14. PROVIDE TEMPORARY ERECTION BRACING AND SUPPORTS TO HOLD STRUCTURAL STEEL FRAMING
SECURELY IN POSITION. SUCH TEMPORARY BRACING AND SUPPORTS SHALL NOT BE REMOVED UNTIL
PERMANENT BRACING HAS BEEN INSTALLED AND CONCRETE HAS ATTAINED 75% OF SPECIFIED
CONCRETE COMPRESSIVE STRENGTH.
15. STRUCTURAL FRAMING SHALL BE TRUE AND PLUMB BEFORE CONNECTIONS ARE FINALLY BOLTED OR WELDED. WHERE STEEL SHELF ANGLES FOR FACADE SUPPORT ARE PRESENT, TOP OF SHELF ANGLE ON
SUCCESSIVE FLOORS WILL BE SET IN SAME VERTICAL PLANE.
16. FIELD CUTTING OF STRUCTURAL FRAMING AND / OR FIELD MODIFICATIONS OF STRUCTURAL FRAMING
SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL BY ENGINEER OF RECORD FOR EACH
SPECIFIC CASE.
17. UNLESS OTHERWISE SHOWN, COLUMNS SHALL BE EXTENDED TO TOPS OF BEAMS AND FRAMED
CONNECTIONS.
18. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL PLATES, CLIP ANGLES, CONNECTION MATERIALS, ETC. AS REQUIRED FOR COMPLETION OF THE STRUCTURE, EVEN IF SUCH ITEMS ARE NOT SPECIFICALLY
SHOWN ON THE STRUCTURAL DRAWINGS.
19. THE CONTRACTOR SHALL FURNISH AND / OR INSTALL STRUCTURAL FRAMING OR MISCELLANEOUS LINTELS INDICATED BY ARCHITECTURAL, HVAC, ELECTRICAL, OR PLUMBING DOCUMENTS, PROVIDED:
A. NO CORRESPONDING MEMBER APPEARS ON STRUCTURAL DOCUMENTS, AND
B. NO OTHER TRADES ARE NOTED TO PROVIDE AND INSTALL SUCH COMPONENTS.
STEEL GRATING NOTES
1. STEEL GRATING SHALL BE 19W4 BAR GRATING AS FOLLOWS:
A. BEARING BAR SPACING: 1 3/16" OC
B. BEARING BAR DEPTH: 1 1/2"
C. BEARING BAR THICKNESS: 3/16"
D. CROSS BAR SPACING: 4" OC
E. TYPE: GALVANIZED STEEL
F. FINISH: PLAIN
2. FABRICATION OF GRATING SHALL COMPLY WITH NAAMM MBG 531, "METAL BAR GRATING MANUAL FOR STEEL, STAINLESS STEEL, AND ALUMINUM GRATINGS AND STAIR TREADS" OR NAAM MBG 532, "HEAVY
DUTY METAL BAR GRATING MANUAL FOR STRUCTURAL CARBON STEEL AND STAINLESS STEEL,"
WHICHEVER IS APPLICABLE.
3. THE FOLLOWING ITEMS SHALL BE SUBMITTED FOR APPROVAL:
A. PRODUCT DATA FOR METAL BAR GRATING, CLIPS, AND ANCHORAGE DEVICES FOR GRATING.
B. SHOP DRAWINGS DETAILING FABRICATION AND ERECTION OF GRATING, WITH PLANS, SECTIONS, AND
DETAILS OF CONNECTIONS.
4. EDGE BAND ALL SECTIONS OF GRATING WITH BARS OF THE SAME SIZE AND MATERIAL AS THE BEARING
BARS.
5. GRATING SHALL BE REMOVABLE
6. GRATING SHALL BE PLACED SUCH THAT CROSS BARS AND BEARING BARS ALIGN.
7. UTILIZE STANDARD PANEL WIDTHS WHEREVER POSSIBLE.
METAL DECK:
1. COMPOSITE FLOOR DECK SHALL CONFORM TO THE FOLLOWING:
A. THE REQUIREMENTS OF THE STEEL DECK INSTITUTE.
B. CONTINUOUS OVER THREE OR MORE SPANS.
C. MANUFACTURED FROM STEEL CONFORMING TO ASTM A653 GRADE 33, OR EQUAL, WITH A MINIMUM
YIELD STRENGTH OF 33 KSI.
D. FINISH SHALL BE MANUFACTURER'S GALVANIZED FINISH.
E. STEEL DECK SHALL BE ATTACHED TO SUPPORTING STEEL WITH A 36/7 PATTERN PUDDLE WELD IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS WITH (4) #10 TEK SCREW SIDELAP
FASTENERS PER SPAN AT INTERVALS NOT EXCEEDING 30 INCHES, UNLESS OTHERWISE NOTED.
F. DECK ENDS SHALL BE BUTTED OVER A SUPPORT WITH MAXIMUM GAP WIDTH OF 1/2 INCH.
G. DECK GAGE AND DEPTH HAVE BEEN SELECTED BASED ON THE WET WEIGHT OF CONCRETE AND THE
FINAL DESIGN LOADS ONLY. CONSTRUCTION MATERIALS SHALL NOT BE PLACED ON THE BARE METAL
DECK.
H. THE FINAL SLAB THICKNESS SHALL BE NO LESS THAN INDICATED AND SHALL BE FINISHED TO A LEVEL
SURFACE. CONTRACTOR SHALL PROVIDE ADDITIONAL CONCRETE REQUIRED TO COMPENSATE FOR
THE DEFLECTION OF UNSHORED BEAMS AND DECK.
2. PUDDLE WELDS SHALL BE 5/8 INCH DIAMETER FULL FUSION (MINIMUM). ALL WELDS SHALL BE MADE WITH AWS E70 ELECTRODES AND METAL AROUND WELDS SHALL BE COMPLETELY INTACT AFTER WELDING.
3. METAL DECK FINISH SHALL BE RETOUCHED IF DAMAGED DUE TO PLACING, HANDLING, AND/OR WELDING.
4. SEAL ALL BLOW HOLES AND LAPPED EDGES BEFORE INSTALLATION.
5. DECK SHALL BE FABRICATED SO THAT THE DECK RUNS CONTINUOUSLY OVER OPENINGS. THE OPENINGS
IN THE DECK SHALL NOT BE CUT UNTIL THE OPENING IS NEEDED. ALL SKEW CUTTING SHALL BE DONE IN
THE FIELD.
6. CONTRACTOR SHALL COORDINATE ALL TRADE REQUIREMENTS AND CONFIRM THE SIZE AND LOCATION OF ALL OPENINGS. OPENINGS LARGER THAN 12 INCHES, AND AS DETAILED, SHALL HAVE STEEL FRAMING
SUPPORTING ALL EDGES. SEE TYPICAL DETAILS FOR DECK OPENING FRAMING DETAILS.
STRUCTURAL MASONRY NOTES:
1. MASONRY CONSTRUCTION SHALL CONFORM TO REQUIREMENTS OF UFC 3-310-05A AND BY REFERENCE
THE SPECIFICATION FOR MASONRY STRUCTURES (TMS 402/602), UNLESS OTHERWISE NOTED.
2. STRENGTH OF MASONRY MATERIALS SHALL BE AS FOLLOWS:
A. CONCRETE MASONRY UNITS SHALL BE NORMAL WEIGHT OR LIGHT WEIGHT, GRADE N, TYPE 1, CONFORMING TO ASTM C90 AND HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI ON THE
NET AREA.
B. MORTAR SHALL CONFORM TO ASTM C270 TYPE M OR S.
C. SELF-CONSOLIDATING GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE SIZE
OF 3/8 INCH AND A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI GROUT. TESTS SHALL BE
CONDUCTED IN ACCORDANCE WITH TMS 402/602.
D. REINFORCED MASONRY SHALL HAVE A COMPRESSIVE STRENGTH AT 28 DAYS, fm' = 2,000 PSI, AS
DETERMINED BY THE UNIT STRENGTH METHOD.
3. VERTICAL REINFORCEMENT FOR CONCRETE MASONRY SHALL BE ASTM A-615, GRADE 60. SPLICES SHALL
BE LAPPED 48 BAR DIAMETERS MINIMUM.
4. REINFORCED MASONRY WALLS SHALL HAVE BOND BEAMS AT EACH FLOOR LEVEL, ROOF LEVEL, TOP OF
WALLS, AT MAXIMUM SPACING OF 10 FEET AND AS INDICATED IN THE DRAWINGS. BOND BEAM
REINFORCING SHALL EXTEND INTO AND BE CONTINUOUS WITH INTERSECTING BOND BEAMS. FILL BOND
BEAMS WITH COARSE GROUT.
5. CONCRETE MASONRY WALLS, UNLESS OTHERWISE INDICATED, SHALL HAVE LADDER-TYPE HORIZONTAL JOINT REINFORCEMENT MADE OF 9 GAUGE SIDE AND INTERMEDIATE BARS OF COLD DRAWN STEEL WIRE MEETING THE REQUIREMENTS OF ASTM A-82. HORIZONTAL JOINT REINFORCEMENT SHALL BE PLACED AT
16 INCHES ON CENTER VERTICALLY UNLESS OTHERWISE NOTED AND SHALL HAVE A HOT DIP
GALVANIZED FINISH IN ACCORDANCE WITH ASTM A153 CLASS B-2. INTERMEDIATE BAR SPACING SHALL BE
16 INCHES ON CENTER.
6. FILL BLOCK CORES CONTAINING REINFORCEMENT FULL WITH GROUT. CROSS WEBS OF CORES
CONTAINING REINFORCEMENT ARE TO BE MORTAR BEDDED.
7. THE BASE OF EACH CELL IN WHICH A VERTICAL BAR IS PLACED SHALL HAVE A CLEAN-OUT HOLE
MEASURING A MINIMUM OF 2 INCHES BY 3 INCHES.
8. DO NOT GROUT CELLS UNTIL INSPECTION AND REINFORCEMENT OF CELLS IS COMPLETE.
9. THE BEARING BLOCK BENEATH BEAMS OR OTHER CONCENTRATED LOADS SHALL BE GROUTED SOLID
FOR A WIDTH OF AT LEAST 2' - 0" AND A DEPTH OF AT LEAST 3 COURSES (2' - 0") MINIMUM.
10. AT MASONRY WALLS: PROVIDE ONE (1) #5 VERTICAL REINFORCING BAR AS FOLLOWS:
A. AT CORNERS.
B. WITHIN 16 INCHES OF EACH SIDE OF WALL OPENINGS.
C. WITHIN 8 INCHES OF EACH SIDE OF CONTROL JOINTS.
D. WITHIN 8 INCHES OF ENDS OF WALLS.
PROVIDE TWO (2) #5 REINFORCING BARS AS FOLLOWS:
E. HORIZONTAL IN BOND BEAMS
11. AT MASONRY WALLS PROVIDE MINIMUM VERTICAL REINFORCEMENT OF #5@4' - 0", UNLESS OTHERWISE
NOTED.
12. REINFORCED MASONRY PIERS / PILASTERS SHALL HAVE 3/16 INCH DIAMETER, MILL-GALVANIZED, CLOSED
WIRE TIES AT 8 INCHES ON CENTER VERTICALLY, UNLESS OTHERWISE NOTED.
13. BONDING METHODS, TIES, LINTELS AND ACCESSORIES SHALL BE APPROVED BY THE ENGINEER OF
RECORD.
14. MASONRY OPENINGS MORE THAN 16 INCHES WIDE IN NON-BEARING WALLS IN NEW OR EXISTING
CONSTRUCTION REQUIRE LINTELS IN ACCORDANCE WITH THE FOLLOWING SCHEDULE UNLESS
OTHERWISE INDICATED:
MAX. OPENING 4" THICK 8" THICK 10" THICK 12" THICK
3' - 0" (1) L3 1/2X3 1/2X1/4 (2) L3 1/2X3 1/2X5/16 (2) L4X4X5/16 (2) L5X5X5/16 4' - 0" (1) L4X3 1/2X1/4 (2) L4X3 1/2X5/16 (2) L4X4X5/16 (2) L5X5X5/16 5' - 0" (1) L4X3 1/2X5/16 (2) L4X3 1/2X5/16 (2) L4X4X5/16 (2) L5X5X5/16 6' - 0" (1) L5X3 1/2X5/16 (2) L5X3 1/2X5/16 W8X24 W/ 5/16" B PL W8X31 W/ 5/16 B PL
7' - 0" (1) L6X3 1/2X3/8 (2) L6X3 1/2X3/8 W8X24 W/ 5/16" B PL W8X31 W/ 5/16 B PL
COORDINATE WITH THE LINTEL SCHEDULE FOR WALLS LARGER THAN THE ABOVE THICKNESSES, USE MULTIPLES OF THE ABOVE PIECES. LINTEL SHALL BE 1' - 4" LONGER THAN MASONRY OPENINGS. LONG LEGS OF ANGLE STEEL SHALL BE VERTICAL. WHERE LINTEL ABUTS COLUMNS OR WALLS, PROVIDE
CONNECTION TO SUCH. SUBMIT SHOP DRAWINGS OF CONNECTION DETAIL FOR APPROVAL.
15. WHERE MASONRY PARTITION WALLS EXTEND TO DECK / FLOOR / ROOF OR AROUND STRUCTURAL MEMBERS AN APPROPRIATE CLEARANCE (1 INCH MINIMUM - 2 INCH MAXIMUM) SHALL BE PROVIDED TO
PREVENT TRANSFER OF GRAVITY LOADS INTO PARTITIONS. GAPS SHALL BE SEALED FOR FIRE
SEPARATION AND / OR SOUND TRANSMISSION AS INDICATED ON ARCHITECTURAL DRAWINGS. LATERAL
BRACING OF TOP OF PARTITION SHALL BE AS SHOWN ON DRAWINGS.
16. ADEQUATE TEMPORARY BRACING FOR WIND AND CONSTRUCTION LOADS SHALL BE PROVIDED AT ALL TIMES DURING INSTALLATION OF MASONRY UNTIL SUCH TIME AS THE MASONRY HAS REACHED ITS
DESIGN STRENGTH AND THE STRUCTURE IS IN ITS COMPLETED FORM. DESIGN, STAGING, AND
INSTALLATION OF TEMPORARY BRACING SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
17. ANCHORAGE TO MASONRY SHALL BE AS FOLLOWS, OR ENGINEER OF RECORD APPROVED EQUIVALENT:
A. SOLID GROUTED MASONRY
1. ADHESIVE ANCHORS SHALL USE AN EPOXY ADHESIVE ANCHORING SYSTEM WITH CONTINUOUSLY
THREADED ROD OR CONTINUOUSLY DEFORMED STEEL REBAR.
2. MECHANICAL ANCHORS SHALL BE EXPANSION ANCHORS.
B. HOLLOW / MULTI-WYTHE MASONRY
1. ADHESIVE ANCHORS SHALL USE AN EPOXY ADHESIVE ANCHORING SYSTEM WITH CONTINUOUSLY
THREADED ROD OR CONTINUOUSLY DEFORMED STEEL REBAR.
2. THE APPROPRIATE SIZE SCREEN TUBE SHALL BE USED PER ADHESIVE MANUFACTURER'S
RECOMMENDATION.
CONTROLLED LOW-STRENGTH MATERIAL:
1. CONTROLLED LOW-STRENGTH MATERIAL (FLOWABLE FILL) SHALL CONFORM TO ACI SP-150,
"CONTROLLED LOW-STRENGTH MATERIALS," AND NATIONAL READY MIXED CONCRETE ASSOCIATION'S
"GUIDE SPECIFICATION FOR CONTROLLED LOW STRENGTH MATERIALS."
2. CONTROLLED LOW-STRENGTH MATERIAL SHALL MEET THE FOLLOWING SPECIFICATIONS MEASURED IN
ACCORDANCE WITH ASTM C 495:
A. AIR DRY DENSITY: 70 - 145 POUNDS PER CUBIC FOOT
B. COMPRESSIVE STRENGTH: MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 140 PSI
C. BEARING CAPACITY: MINIMUM 28 DAY BEARING CAPACITY OF 10 TONS PER SQUARE FOOT
ALUMINUM
BOARD INSULATION
BRICK
COMPACTED GRANULAR
BASE
COMPACTED STONE FILL
CONCRETE
CONCRETE MASONRY
UNITS
DECK SPAN
FINAL GRADE
GRATING
GROUT
REINFORCING STEEL IN
CONCRETE
SLOPES
STEEL
UNDISTURBED EARTH
UNDISTURBED ROCK
SAND
DEMOLITION
AT
THE ALUMINUM ASSOCIATION
ANCHOR BOLT
AGGREGATE BASE COURSE
AMERICAN CONCRETE INSTITUTE
ADDITIONAL
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ABOVE FINISHED SLAB
AGGREGATE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AMERICAN INSTITUTE OF TIMBER CONSTRUCTION
ALUMINUM
ALTERNATE
AMERICAN NATIONAL STANDARD INSTITUTE
APPROVED
APPROXIMATE
AS REQUIRED
ARCHITECT, ARCHITECTURAL
AMERICAN SOCIETY OF CIVIL ENGINEERS
ALLOWABLE STRESS DESIGN
AMERICAN SOCIETY FOR TESTING AND MATERIALS
AMERICAN WOOD COUNCIL
AMERICAN WELDING SOCIETY
BASE PLATE
BOTTOM ELEVATION
BOTH FACES
BELOW FINISHED FLOOR
BUILDING
BEAM
BOTTOM OF STEEL
BOTTOM
BRACING
BEARING
BASEMENT
BOTH WAYS
COMPRESSION
CHANNEL
COLD FORMED METAL FRAMING
CHEMICAL
CHAMFER
CAST-IN-PLACE
CONTROL JOINT, CONSTRUCTION JOINT
CENTER LINE
COLUMN LINE
CEILING
CLEAR
CONTROLLED LOW-STRENGTH MATERIAL
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUE, CONTINUOUS
CONTRACTOR
COORDINATE
CONCRETE REINFORCING STEEL INSTITUTE
CUBIC YARDS
PENNY (NAIL SIZE)
DEMOLISH, DEMOLITION
DETAIL
DRY FILM THICKNESS
DIAMETER
DIAGONAL
DIMENSION
DEAD LOAD
DEPARTMENT OF TRANSPORTATION
DRAWING
DOWEL
EAST
EACH
EACH FACE
EXPANSION JOINT
ELEVATION
ELECTRIC, ELECTRICAL
EMBEDMENT
ENGINEER
ENGINEER OF RECORD
EDGE OF SLAB
EQUAL
EQUIPMENT
EQUIVALENT
EACH WAY
EXISTING
EXPANSION
EXTERIOR
SPECIFIED COMPRESSIVE STRENGTH
OF CONCRETE
FLOOR DRAIN
FINISH
SPECIFIED COMPRESSIVE STRENGTH
OF CONCRETE MASONRY
FIBER REINFORCED CONCRETE
FIBERGLASS REINFORCED PLASTIC
FAR SIDE
FEET
FOOTING
MINIMUM YIELD STRESS
GAGE
GALVANIZED
GRADE BEAM
GRATING
HIGH DENSITY POLYETHYLENE
HORIZONTAL
HIGH POINT
HIGH STRENGTH
HEATING, VENTILATING AND AIR CONDITIONING
INTERNATIONAL BUILDING CODE
INTERNATIONAL CODE COUNCIL EVALUATING
SERVICE
INSIDE DIAMETER
INSIDE FACE
INCHES
INFORMATION
INSULATION
INTERIOR
INVERT
JT
K OR KIP
KB
KD
K/FT
KIP FT
KLF
KSF
LBS
LL
LLH
LLO
LLV
LONG
LPT
LRFD
LW
MATL
MAX
MECH
MEZZ
MFR
MD
MH
MIL
MIN
MISC
ML
MTL
MO
MPII
N
NF
NIC
NO
No.
NS
NTS
OC
OD
OF
OH
OPNG
OPP
OSHA
P/C OR PCP
PCC
PCI
PH
PL
PREFAB
PSF
PSI
PVC
R
RD
REBAR
REF
REINF
REQD
REV
RM
S
SCG
SCHED
SE
SECT
SF
SIM
SJI
SQ
SS
SSR
SST
STD
STIFF
STIR
STL
STRUCT
SYMM
(T) T T&B T&G
TE
TEMP
TFF
TO
TOB
TOC
TOF
TOS
TOW
TPER
TPI
TYP
UN
UNO
UON
VERT
VIF
VRFY
W W/
WF
WF BM
W/O
WP
WS
XBRA
AA
AB
ABC
ACI
ADDL
AFF
AFG
AFS
AGGR
AISC
AITC
ALUM
ALT
ANSI
APPD
APPROX
AR
ARCH
ASCE
ASD
ASTM
AWC
AWS
B PL
BE
BF
BFF
BLDG
BM
BOS
BOT
BRCG
BRG
BSMT
BW
(C) C
CFMF
CHEM
CHFR
CIP
CJ
CL
CLL
CLG
CLR
CLSM
CMU
COL
CONC
CONN
CONSTR
CONT
CONTR
COORD
CRSI
CY
D
DEMO.
DET
DFT
DIA OR Ø
DIAG
DIM
DL
DOT
DWG
DWL
E
EA
EF
EJ
EL
ELEC
EMBED
ENGR
EOR
EOS
EQ
EQUIP
EQUIV
EW
EX
EXP
EXT
fc'
FD
FIN
fm'
FRC
FRP
FS
FT
FTG
fy
GA
GALV
GR BM
GRTG
HDPE
HORIZ
HP
HS
HVAC
IBC
ICC-ES
ID
IF
IN
INFO
INSUL
INT
INV
JOINT
THOUSAND POUNDS (1 K = 1000 LBS)
KNEE BRACE
KILN DRIED
KIPS PER FOOT
THOUSAND FOOT/POUNDS
KIPS PER LINEAR FOOT
KIPS PER SQUARE FOOT
POUNDS
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG OUTSTANDING
LONG LEG VERTICAL
LONGITUDINAL
LOW POINT
LOAD AND RESISTANCE FACTOR DESIGN
LIGHTWEIGHT
MATERIAL
MAXIMUM
MECHANICAL
MEZZANINE
MANUFACTURER
METAL DECK
MANHOLE
ONE THOUSANDTH OF AN INCH
MINIMUM
MISCELLANEOUS
MASONRY LINTEL (STEEL)
METAL
MASONRY OPENING
MANUFACTURER'S PRINTED
INSTALLATION INSTRUCTIONS
NORTH
NEAR FACE
NOT IN CONTRACT
NUMBER
NUMBER SYMBOL FOR REBAR SIZE
NUMBER SYMBOL FOR WOOD GRADE
NEAR SIDE
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OUTSIDE FACE
OPPOSITE HAND
OPENING
OPPOSITE
OCCUPATIONAL SAFETY AND HEALTH
ADIMINISTRATION
PRECAST PLANK
PRECAST CONCRETE
PRECAST / PRESTRESSED CONCRETE
INSTITUTE
PENTHOUSE
PLATE
PREFABRICATED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POLYVINYL CHLORINE
RADIUS OR RISER
ROOF DRAIN
REINFORCING STEEL BAR
REFERENCE
REINFORCED
REQUIRED
REVISION
ROOM
SOUTH
SELF-CONSOLIDATING GROUT
SCHEDULE
STRUCTURAL ENGINEER
SECTION
SQUARE FEET
SIMILAR
STEEL JOIST INSTITUTE
SQUARE
STANDING SEAM (ROOF)
STANDING SEAM ROOFING
STAINLESS STEEL
STANDARD
STIFFENER
STIRRUP
STEEL
STRUCTURAL
SYMMETRICAL
TENSION
TREAD, TOP
TOP AND BOTTOM
TONGUE & GROOVE
TOP ELEVATION
TEMPERATURE, TEMPORARY
TOP OF FINISH FLOOR
TOP OF _____
TOP OF BEAM
TOP OF CONCRETE
TOP OF FOOTING
TOP OF SLAB, TOP OF STEEL
TOP OF WALL
THERMOPLASTIC ELASTOMERIC RUBBER
TRUSS PLATE INSTITUTE
TYPICAL
UNLESS NOTED
UNLESS NOTED OTHERWISE
UNLESS OTHERWISE NOTED
VERTICAL
VERIFY IN FIELD
VERIFY
WEST
WITH
WIDE FLANGE
WIDE FLANGE BEAM
WITHOUT
WORKING POINT
WATERSTOP
CROSSBRACING
STRUCTURAL DESIGN CRITERIA
1ST FLOOR WAREHOUSE: 250 (PSF)
2ND FLOOR LABORATORY: 125 (PSF)
SAFECHROME 336 GALLON TANK: 380 (PSF)
WASTEWATER 850 GALLON TANK: 580 (PSF)
45° CONE 300 GALLON TANK: 335 (PSF)
STAIRWAYS, LANDINGS, & GRATED WALKWAYS: 100 (PSF)
BRIDGE CRANE: 1 (TON)
FLOOR LIVE LOADS:
ROOF LIVE LOADS:
ROOF SNOW LOADS:
WIND DESIGN DATA:
EARTHQUAKE DESIGN DATA:
MINIMUM ROOF LIVE LOAD: 20 (PSF)
ROOF DEAD LOADS:
ROOFING DEAD LOADS: 65 (PSF)
COLLATERAL LOADS: 10 (PSF)
HVAC EQUIPMENT: SEE PLANS
GROUND SNOW LOAD, Pg: 40 (PSF) FLAT-ROOF SNOW LOAD, Pf: 28 (PSF) SNOW EXPOSURE FACTOR, Ce: 1.0 SNOW LOAD IMPORTANCE FACTOR, Is: 1.0 THERMAL FACTOR, Ct: 1.0
DRIFT SURCHARGE LOADS: VARIES PER LOCATION
ULTIMATE DESIGN WIND SPEED, Vult (3s): 110 (MPH)
RISK CATEGORY: II
WIND EXPOSURE: C
INTERNAL PRESSURE COEFFICIENTS: +/- 0.18
DESIGN WIND PRESSURE USED FOR
COMPONENTS AND CLADDING: VARIES PER COMPONENT AND
LOCATION ON STRUCTURE
SITE LATITUDE: 42.7206 N
SITE LONGITUDE: -73.7094 E
SESIMIC IMPORTANCE FACTOR, Ie: 1.0
RISK CATEGORY: II
MAPPED SPECTRAL RESPONSE ACCELERATIONS:
Ss = 0.197g S1 = 0.060g
SITE CLASS: D
DESIGN SPECTRAL RESPONSE ACCELERATIONS:
SDS = 0.210g SD1 = 0.097g
SEISMIC DESIGN CATEGORY: B
BASIC SEISMIC FORCE-RESISTING SYSTEM: ORDINARY REINFORCED
CONCRETE MOMENT FRAMES
DESIGN BASE SHEAR, V: 810 (KIP)
SEISMIC RESPONSE COEFFICIENT(S), CS: 0.07
RESPONSE MODIFICATION COEFFICIENT(S), R: 3
ANALYSIS PROCEDURE: EQUIVELANT LATERAL FORCE
GEOTECHNICAL INFORMATION:
NET ALLOWABLE BEDROCK BEARING PRESSURE: 15,000 (PSF)
NET ALLOWABLE SOIL BEARING PRESSURE: 4,000 (PSF)
FROST DEPTH: 6' - 10" BELOW FINISH GRADE
FLOOD DESIGN DATA:
FLOOD DESIGN CLASS: N/A
LOWEST FLOOR ELEVATION: 66 (FT)
DRY FLOODPROOF ELEVATION: 25 (FT)
BOTTOM OF LOWEST HORIZONTAL
STRUCTURAL MEMBER: 61 (FT)
7" CONCRETE SLAB: 88 (PSF)
COLLATERAL LOADS: 10 (PSF)
FLOOR DEAD LOADS:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
WVA B120
R T
A S
U B
M
IS
S
IO
N /0
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
A u to d e s k D o cs
/A
U S
-0 -U
S A
C E
N
Y W
V A
B ld g R e c a p /S
-W V
A R
.r v t
/2
/2
:2
:2
P
M
S-001
G E
N E
R A
L N
O T
E S
W A
T E
R V
L
IE
T A
R S
E N
A L N
Y
N Y
D
IS
T R
IC
T
A R
C A
D
IS
U .S
I N
C
R
O U
T E
S
U
IT
E
C L
IF
T O
N P
A R
K N
Y
C C
A L K
IN
S
D W
A S
H
IN
G T
O N
C C
A L K
IN
S
L B
O W
E
/0
/2
W D
S F
W D
S F
I D
C -M
R E
C A
P
IT
A L
IZ
A T
IO
N
O F
B U
IL
D
IN
G
B
P R
O J E
C T
N O
W
D
S F
SOILS AND FOUNDATIONS
REQUIRED VERIFICATION AND INSPECTION OF SOILS
1705.6 SOILS. SPECIAL INSPECTIONS AND TESTS OF EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT AND LOAD-BEARING REQUIREMENTS SHALL BE PERFORMED IN ACCORDANCE WITH THIS SECTION AND TABLE 1705.6. THE APPROVED GEOTECHNICAL REPORT AND THE CONSTRUCTION DOCUMENTS PREPARED BY THE REGISTERED DESIGN PROFESSIONALS SHALL BE USED TO DETERMINE COMPLIANCE. DURING FILL PLACEMENT, THE SPECIAL INSPECTOR SHALL VERIFY THAT PROPER MATERIALS AND PROCEDURES ARE USED IN ACCORDANCE WITH THE PROVISIONS OF THE APPROVED
GEOTECHNICAL REPORT.
EXCEPTION: WHERE SECTION 1803 DOES NOT REQUIRE REPORTING OF MATERIALS AND PROCEDURES FOR FILL PLACEMENT, THE SPECIAL INSPECTOR SHALL VERIFY THAT THE IN-PLACE DRY DENSITY OF THE COMPACTED FILL IS NOT LESS THAN 90 PERCENT OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT DETERMINED IN
ACCORDANCE WITH ASTM D 1557.
1705.7 DRIVEN DEEP FOUNDATIONS. SPECIAL INSPECTIONS AND TESTS SHALL BE PERFORMED DURING INSTALLATION OF DRIVEN DEEP FOUNDATION ELEMENTS AS SPECIFIED IN TABLE 1705.7. THE APPROVED GEOTECHNICAL REPORT AND THE CONSTRUCTION DOCUMENTS PREPARED BY THE REGISTERED DESIGN PROFESSIONALS SHALL BE USED TO DETERMINE
COMPLIANCE.
1705.8 CAST-IN-PLACE DEEP FOUNDATIONS. SPECIAL INSPECTIONS AND TESTS SHALL BE PERFORMED DURING INSTALLATION OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS AS SPECIFIED IN TABLE 1705.8. THE APPROVED GEOTECHNICAL REPORT AND THE CONSTRUCTION DOCUMENTS PREPARED BY THE REGISTERED DESIGN PROFESSIONALS
SHALL BE USED TO DETERMINE COMPLIANCE.
1705.9 HELICAL PILE FOUNDATIONS. CONTINUOUS SPECIAL INSPECTIONS SHALL BE PERFORMED DURING INSTALLATION OF HELICAL PILE FOUNDATIONS. THE INFORMATION RECORDED SHALL INCLUDE INSTALLATION EQUIPMENT USED, PILE DIMENSIONS, TIP ELEVATIONS, FINAL DEPTH, FINAL INSTALLATION TORQUE AND OTHER PERTINENT INSTALLATION DATA AS REQUIRED BY THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. THE APPROVED GEOTECHNICAL REPORT AND THE CONSTRUCTION DOCUMENTS PREPARED BY THE REGISTERED DESIGN PROFESSIONAL SHALL BE USED TO
DETERMINE COMPLIANCE.
SCHEDULE OF TESTING AND INSPECTION AGENCIES
1. SPECIAL INSPECTION COORDINATOR
TBA
2. SUPPLEMENTAL INSPECTOR
TBA
SPECIAL INSPECTION AGENCIES FIRM ADDRESS, TELEPHONE, E-MAIL
3. TESTING AGENCY
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TABLE 1705.6 – REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATION ARE ADEQUATE TO ACHIEVE THE
DESIGN BEARING CAPACITY.
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED
PROPER MATERIAL.
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING
PLACEMENT AND COMPACTION OF COMPACTED FILL.
5. PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY THAT
SITE HAS BEEN PREPARED PROPERLY.
TYPE CONTINUOUS PERIODIC
- X
- X
- X
X -
- X
CAST-IN-PLACE CONCRETE
REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
SECTION 1705.3 & TABLE 1705.3 FROM IBC 2018
(CAST-IN-PLACE CONCRETE PORTIONS ONLY)
1705.3 CONCRETE CONSTRUCTION. SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION SHALL BE
PERFORMED IN ACCORDANCE WITH THIS SECTION AND TABLE 1705.3.
EXCEPTION: SPECIAL INSPECTIONS SHALL NOT BE REQUIRED FOR:
1. ISOLATED SPREAD CONCRETE FOOTINGS OF BUILDINGS THREE STORIES OR LESS ABOVE GRADE PLANE THAT
ARE FULLY SUPPORTED ON EARTH OR ROCK.
2. CONTINUOUS CONCRETE FOOTINGS SUPPORTING WALLS OF BUILDINGS THREE STORIES OR LESS ABOVE GRADE
PLANE THAT ARE FULLY SUPPORTED ON EARTH OR ROCK WHERE:
1. THE FOOTINGS SUPPORT WALLS OF LIGHT FRAME CONSTRUCTION.
2. THE FOOTINGS ARE DESIGNED IN ACCORDANCE WITH TABLE 1809.7.
3. THE STRUCTURAL DESIGN OF THE FOOTING IS BASED ON A SPECIFIED COMPRESSIVE STRENGTH, F'C, NO MORE THAN 2,500 POUNDS PER SQUARE INCH, REGARDLESS OF THE COMPRESSIVE STRENGTH
SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS OR USED IN THE FOOTING
CONSTRUCTION.
3. NONSTRUCTURAL CONCRETE SLABS SUPPORTED DIRECTLY ON THE GROUND, INCLUDING PRESTRESSED SLABS ON GRADE, WHERE THE EFFECTIVE PRESTRESS IN THE CONCRETE IS LESS THAN 150 POUNDS PER SQUARE INCH.
4. CONCRETE FOUNDATION WALLS CONSTRUCTED IN ACCORDANCE WITH TABLES 1807.1.6.2.
5. CONCRETE PATIOS, DRIVEWAYS AND SIDEWALKS, ON GRADE.
1705.3.1 WELDING OF REINFORCING BARS. SPECIAL INSPECTIONS OF WELDING AND QUALIFICATION OF SPECIAL INSPECTORS FOR REINFORCING BARS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF AWS D1.4 FOR SPECIAL
INSPECTION AND OF AWS D1.4 FOR SPECIAL INSPECTOR QUALIFICATION.
TABLE 1705.3 – REQUIRED SPECIAL INSPECTIONS AND TESTS OF
CONCRETE CONSTRUCTION
1. INSPECT REINFORCEMENT, INCLUDING
PRESTRESSING TENDONS, AND VERIFY
PLACEMENT
2. REINFORCING BAR WELDING:
a. VERIFY WELDABILITY OF REINFORCING BARS
OTHER THAN ASTM A 706;
b. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16"; AND
c. INSPECT ALL OTHER WELDS.
3. INSPECT ANCHORS CAST IN CONCRETE.
4. INSPECT ANCHORS POST-INSTALLED IN
HARDENED CONCRETE MEMBERS.
a. ADHESIVE ANCHORS INSTALLED IN
HORIZONTALLY OR UPWARDLY INCLINED
ORIENTATIONS TO RESIST SUSTAINED
TENSION LOADS.
b. MECHANICAL ANCHORS AND ADHESIVE
ANCHORS NOT DEFINED IN 4.A.
5. VERIFYING USE OF REQUIRED DESIGN MIX.
6. PRIOR TO CONCRETE PLACEMENT, FABRICATE
SPECIMENS FOR STRENGTH TESTS, PERFORM
SLUMP AND AIR CONTENT TESTS, AND DETERMINE
THE TEMPERATURE OF THE CONCRETE.
7. INSPECT CONCRETE AND SHOTCRETE
PLACEMENT FOR PROPER APPLICATION
TECHNIQUES.
8. VERIFY MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
9. VERIFICATION OF IN-SITU CONCRETE STRENGTH
PRIOR TO REMOVAL OF SHORES AND FORMS
FROM BEAMS AND STRUCTURAL SLABS.
10. INSPECT FORMWORK FOR SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE MEMBER BEING
FORMED.
REFERENCED
STANDARD
IBC
REFERENCE
ACI 318 CH. 20,
25.2, 25.3, 26.6.1-26.6.3 1908.4
TYPE PERIODICCONTINUOUS
- X
AWS D1.4
ACI 318: 26.6.4
X
X
X
ACI 318: 17.8.2 -- X
ACI 318: 17.8.2.4
ACI 318: 17.8.2
X
X
ACI 318: CH. 19,
26.4.3, 26.4.4
1904.1, 1904.2, 1908.2, 1908.3
- X
ASTM C 172
ASTM C 31
ACI 318: 26.5,
26.12
1908.10X -
ACI 318: 26.5
1908.6, 1908.7,
1908.8 X -
ACI 318: 26.11.2 -- X
ACI 318:
26.11.1.2(b)
-- X
ACI 318:
26.5.3-26.5.5
1908.9- X
MASONRY
REQUIRED SPECIAL INSPECTIONS AND TESTS OF MASONRY CONSTRUCTION
TMS 402-16 / TMS 602-16 - QUALITY ASSURANCE PROVISIONS
1705.4 MASONRY CONSTRUCTION. SPECIAL INSPECTIONS AND TESTS OF MASONRY CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE QUALITY ASSURANCE PROGRAM REQUIREMENTS OF TMS 402 AND TMS 602.
EXCEPTION: SPECIAL INSPECTIONS AND TESTS SHALL NOT BE REQUIRED FOR:
1. EMPIRICALLY DESIGNED MASONRY, GLASS UNIT MASONRY OR MASONRY VENEER DESIGNED IN ACCORDANCE WITH SECTION 2109, 2110 OR CHAPTER 14, RESPECTIVELY, WHERE THEY ARE PART OF A STRUCTURE CLASSIFIED
AS RISK CATEGORY I, II OR III.
2. MASONRY FOUNDATION WALLS CONSTRUCTED IN ACCORDANCE WITH TABLE 1807.1.6.3(1), 1807.1.6.3(2), 1807.1.6.3(3) OR 1807.1.6.3(4).
3. MASONRY FIREPLACES, MASONRY HEATERS OR MASONRY CHIMNEYS INSTALLED OR CONSTRUCTED IN
ACCORDANCE WITH SECTION 2111, 2112 OR 2113, RESPECTIVELY.
1705.4.1 EMPIRICALLY DESIGNED MASONRY, GLASS UNIT MASONRY AND MASONRY VENEER IN RISK CATEGORY IV. SPECIAL INSPECTIONS AND TESTS FOR EMPIRICALLY DESIGNED MASONRY, GLASS UNIT MASONRY OR MASONRY VENEER DESIGNED IN ACCORDANCE WITH SECTION 2109, 2110 OR CHAPTER 14, RESPECTIVELY, WHERE THEY ARE PART OF A STRUCTURE CLASSIFIED AS RISK CATEGORY IV SHALL BE PERFORMED IN ACCORDANCE WITH TMS 402, LEVEL B QUALITY ASSURANCE.
1705.4.2 VERTICAL MASONRY FOUNDATION ELEMENTS. SPECIAL INSPECTIONS AND TESTS OF VERTICAL MASONRY
FOUNDATION ELEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH SECTION 1705.4.
TMS 402 TABLE 3.1 – MINIMUM QUALITY ASSURANCE LEVEL
PART 3 OR APPENDIX B OR APPENDIX C
PART 4
APPENDIX A
DESIGNED IN ACCORDANCE WITH RISK CATEGORY
I, II, OR III
RISK CATEGORY
IV
LEVEL 2 LEVEL 3
LEVEL 2LEVEL 1
LEVEL 1 NOT PERMITTED
TMS 602 TABLE 3 – MINIMUM VERIFICATION REQUIREMENTS
1. PRIOR TO CONSTRUCTION, VERIFICATION OF
COMPLIANCE OF SUBMITTALS
2. PRIOR TO CONSTRUCTION, VERIFICATION OF
f’m AND f’AAC, EXCEPT WHERE SPECIFICALLY
EXEMPTED BY THE CODE.
3. DURING CONSTRUCTION, VERIFICATION OF
SLUMP FLOW AND VISUAL STABILITY INDEX
(VSI) WHEN SELF-CONSOLIDATING GROUT IS
DELIVERED TO THE PROJECT SITE.
4. DURING CONSTRUCTION, VERIFICATION OF f’m AND f’AAC FOR EVERY 5,000 SQ. FT.
5. DURING CONSTRUCTION, VERIFICTION OF
PROPORTIONS OF MATERIALS AS DELIVERED
TO THE PROJECT SITE FOR PREMIXED OR
PREBLENDED MORTAR, PRESTRESSING
GROUT, AND GROUT OTHER THAN SELF-
CONSOLIDATING GROUT.
REQUIRED FOR QUALITY ASSURANCE
REFERENCE
FOR CRITERIA
MINIMUM VERIFICATION
REQUIRED ART. 1.4BREQUIRED
REQUIRED ART. 1.5 & 1.6.3
NOT
REQUIRED
REQUIRED
LEVEL 2 LEVEL 3 TMS 602LEVEL 1
REQUIRED ART. 1.5REQUIRED
REQUIRED ART. 1.4B
NOT
REQUIRED
NOT
REQUIRED
REQUIRED ART. 1.4B
NOT
REQUIRED
NOT
REQUIRED
TMS 602 TABLE 4 – MINIMUM SPECIAL INSPECTION REQUIREMENTS
1. AS MASONRY CONSTRUCTION BEGINS, VERIFY
THAT THE FOLLOWING ARE IN COMPLIANCE:
a. PROPORTIONS OF SITE-PREPARED MORTAR
b. GRADE AND SIZE OF PRESTRESSING
TENDONS AND ANCHORAGES
c. GRADE, TYPE AND SIZE OF REINFORCEMENT, CONNECTORS, ANCHOR BOLTS, AND
PRESTRESSING TENDONS AND ANCHORAGES
d. PRESTRESSING TECHNIQUE
e. PROPERTIES OF THIN-BED MORTAR FOR AAC MASONRY(a)
f. SAMPLE PANEL CONSTRUCTION
2. PRIOR TO GROUTING, VERIFY THAT THE
FOLLOWING ARE IN COMPLIANCE:
a. GROUT SPACE
b. PLACEMENT OF PRESTRESSING TENDONS
AND ANCHORAGES
c. PLACEMENT OF REINFORCEMENT, CONNECTORS, AND ANCHOR BOLTS
d. PROPORTIONS OF SITE-PREPARED GROUT
AND PRESTRESSING GROUT FOR BONDED
TENDONS
3. VERIFY COMPLIANCE OF THE FOLLOWING DURING
CONSTRUCTION:
a. MATERIALS AND PROCEDURES WITH THE
APPROVED SUBMITTALS
b. PLACEMENT OF MASONRY UNITS AND MORTAR
JOINT CONSTRUCTION
c. SIZE AND LOCATION OF STRUCTURAL
MEMBERS
d. TYPE, SIZE, AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF ANCHORAGE
OF MASONRY TO STRUCTURAL MEMBERS,
FRAMES, OR OTHER CONSTRUCTION
e. WELDING OF REINFORCEMENT
f. PREPARATION, CONSTRUCTION, AND
PROTECTION OF MASONRY DURING COLD
WEATHER (TEMPERATURE BELOW 40˚F) OR
HOT WEATHER (TEMPERATURE ABOVE 90˚F)
g. APPLICATION AND MEASUREMENT OF
PRESTRESSING FORCE
h. PLACEMENT OF GROUT AND PRESTRESSING
GROUT FOR BONDED TENDONS IS IN
COMPLIANCE
i. PLACEMENT OF AAC MASONRY UNITS AND
CONSTRUCTION OF THIN-BED MORTAR
JOINTS(a)
4. OBSERVE PREPARATION OF GROUT SPECIMENS,
MORTAR SPECIMENS, AND/OR PRISMS
FREQUENCY
REFERENCE FOR
CRITERIA
MINIMUM VERIFICATION
PERIODIC
ART. 2.1,
2.6A, 2.6C
NOT
REQUIRED
PERIODIC
LEVEL 2 LEVEL 3 TMS 602LEVEL 1 TMS 402
PERIODIC
ART. 2.4B,
2.4H
NOT
REQUIRED
PERIODIC
REQUIRED
NOT
REQUIRED
PERIODIC
ART. 3.4,
3.6A
NOT
REQUIRED
PERIODIC
PERIODIC ART. 3.6B
NOT
REQUIRED
PERIODIC
CONTINUOUS ART. 2.1 C.1
NOT
REQUIRED
CONTINUOUS
CONTINUOUS ART. 1.6D
NOT
REQUIRED
PERIODIC
CONTINUOUS
ART. 3.2D,
3.2F
NOT
REQUIRED
PERIODIC
PERIODIC ART. 2.4, 3.6
NOT
REQUIRED
PERIODIC
SEC. 10.8,
10.9
CONTINUOUS
ART. 3.2E,
3.4
NOT
REQUIRED
PERIODIC
SEC. 6.1, 6.3.1,
6.3.6, 6.3.7
PERIODIC
ART. 2.6B,
2.4 G.1.b
NOT
REQUIRED
PERIODIC
PERIODIC ART. 1.5
NOT
REQUIRED
PERIODIC
PERIODIC ART. 3.3B
NOT
REQUIRED
PERIODIC
PERIODIC ART. 3.3F
NOT
REQUIRED
PERIODIC
PERIODIC
NOT
REQUIRED
PERIODIC
SEC. 1.2.1(e), 6.2.1, 6.3.1
CONTINUOUS
NOT
REQUIRED
CONTINUOUS SEC. 6.1.6.1.2
PERIODIC
NOT
REQUIRED
PERIODIC
ART. 1.8C,
1.8D
CONTINUOUS
NOT
REQUIRED
CONTINUOUS ART. 3.6B
CONTINUOUS
ART. 3.5,
3.6C
NOT
REQUIRED
CONTINUOUS
CONTINUOUS
ART. 3.3B.9,
3.3F.1.b
NOT
REQUIRED
CONTINUOUS
PERIODIC
NOT
REQUIRED
PERIODIC
ART.
1.4B.2.a.3, 1.4B.2.b.3, 1.4B.2.c.3, 1.4B.3, 1.4B.4
a. LEVEL 2: CONTINUOUS FREQUENCY FOR THE FIRST 5,000 SQUARE FEET OF AAC MASONRY, PERIODIC FREQUENCY
AFTER THE FIRST 5,000 SQUARE FEET OF AAC MASONRY.
STRUCTURAL STEEL (INCLUDING JOISTS)
REQUIREMENTS FOR INSPECTION OF STRUCTURAL STEEL
AISC 360-16: CHAPTER N5 (QUALITY ASSURANCE PROVISIONS)
1705.2 STEEL CONSTRUCTION. THE SPECIAL INSPECTIONS AND NON-DESTRUCTIVE TESTING OF STEEL CONSTRUCTION IN BUILDINGS, STRUCTURES, AND PORTIONS THEREOF SHALL BE IN ACCORDANCE WITH THIS SECTION.
EXCEPTION: SPECIAL INSPECTIONS OF THE STEEL FABRICATION PROCESS SHALL NOT BE REQUIRED WHERE THE FABRICATION PROCESS FOR THE ENTIRE BUILDING OR STRUCTURE DOES NOT INCLUDE ANY WELDING, THERMAL CUTTING OR HEATING OPERATION OF ANY KIND. IN SUCH CASES, THE FABRICATOR SHALL BE REQUIRED TO SUBMIT A DETAILED PROCEDURE FOR MATERIAL CONTROL THAT DEMONSTRATES THE FABRICATOR’S ABILITY TO MAINTAIN SUITABLE RECORDS AND PROCEDURES SUCH THAT, AT ANY TIME DURING THE FABRICATION PROCESS, THE MATERIAL SPECIFICATION AND GRADE FOR THE MAIN STRESS-CARRYING ELEMENTS ARE CAPABLE OF BEING DETERMINED. MILL TEST REPORTS SHALL BE IDENTIFIABLE TO THE MAIN STRESS-CARRYING ELEMENTS WHERE REQUIRED BY THE
APPROVED CONSTRUCTION DOCUMENTS.
1705.2.1 STRUCTURAL STEEL. SPECIAL INSPECTIONS AND NONDESTRUCTIVE TESTING OF STRUCTURAL STEEL ELEMENTS IN BUILDINGS, STRUCTURES AND PORTIONS THEREOF SHALL BE IN ACCORDANCE WITH THE QUALITY ASSURANCE INSPECTION
REQUIREMENTS OF AISC 360.
EXCEPTION: SPECIAL INSPECTION OF RAILING SYSTEMS COMPOSED OF STRUCTURAL STEEL ELEMENTS SHALL BE
LIMITED TO WELDING INSPECTION OF WELDS AT THE BASE OF CANTILEVERED RAIL POSTS.
1705.2.2 COLD-FORMED STEEL DECK. SPECIAL INSPECTIONS AND QUALIFICATION OF WELDING SPECIAL INSPECTORS FOR COLD-FORMED STEEL FLOOR AND ROOF DECK SHALL BE IN ACCORDANCE WITH THE QUALITY ASSURANCE INSPECTION
REQUIREMENTS OF SDI QA/QC.
1705.2.3 OPEN-WEB STEEL JOISTS AND JOIST GIRDERS. SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS IN BUILDINGS, STRUCTURES AND PORTIONS THEREOF SHALL BE IN ACCORDANCE WITH TABLE 1705.2.3.
1705.2.4 COLD-FORMED STEEL TRUSSES SPANNING 60 FEET OR GREATER. WHERE A COLD-FORMED STEEL TRUSS CLEAR SPAN IS 60 FEET (18 288 MM) OR GREATER, THE SPECIAL INSPECTOR SHALL VERIFY THAT THE TEMPORARY INSTALLATION RESTRAINT/BRACING AND THE PERMANENT INDIVIDUAL TRUSS MEMBER RESTRAINT/BRACING ARE INSTALLED IN
ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE.
AISC 360 SECTION N5 SUMMARY TABLE – STEEL INSPECTION REQUIREMENTS
1. REVIEW MATERIAL TEST REPORTS AND CERTIFICATIONS AS LISTED IN SECTION N3.2
FOR COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS.
2. INSPECT THE FABRICATED STEEL TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN
ON THE SHOP DRAWINGS.
3. INSPECT THE ERECTED STEEL FRAME TO VERIFY COMPLIANCE WITH THE FIELD
INSTALLED DETAILS SHOWN ON THE ERECTION DRAWINGS.
4. INSPECTION DURING THE PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS
SUPPORTING STRUCTURAL STEEL FOR COMPLIANCE WITH THE CONSTRUCTION
DOCUMENTS.
5. INSPECT THE FABRICATED STEEL OR ERECTED STEEL FRAME, AS APPLICABLE, TO
VERIFY COMPLIANCE WITH THE DETAILS SHOWN ON THE CONSTRUCTION
DOCUMENTS.
6. EXPOSED CUT SURFACES OF GALVANIZED STRUCTURAL STEEL MAIN MEMBERS AND
EXPOSED CORNERS OF RECTANGULAR HSS SHALL BE VISUALLY INSPECTED FOR
CRACKS SUBSEQUENT TO GALVANIZING. CRACKS SHALL BE REPAIRED OR THE
MEMBER SHALL BE REJECTED.
7. THE ACCEPTANCE OR REJECTION OF JOINT DETAILS AND THE CORRECT APPLICATION
OF JOINT DETAILS SHALL BE DOCUMENTED.
INSPECTION TASK QA QC
a. OBSERVE (O): THE INSPECTOR SHALL OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED
PENDING THESE INSPECTIONS.
b. PERFORM (P): THESE TASKS SHALL BE PERFORMED FOR EACH WELDED JOINT OR MEMBER AND EACH BOLTED
CONNECTION.
SECTION N5 - OTHER INSPECTION TASKS
O -
- O
- O
O -
O -
O O
TABLE N5.4-1 INSPECTION TASKS PRIOR TO WELDING
1. WELDER QUALIFICATION RECORDS AND CONTINUITY RECORDS
2. WPS AVAILABLE
3. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE
4. MATERIAL IDENTIFICATION (TYPE/GRADE)
5. WELDER IDENTIFICATION SYSTEM[a]
6. FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY)
• JOINT PREPARATIONS
• DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)
• CLEANLINESS (CONDITION OF STEEL SURFACES)
• TACKING (TACK WELD QUALITY AND LOCATION)
• BACKING TYPE AND FIT (IF APPLICABLE)
7. FIT-UP OF CJP GROOVE WELDS OF HSS T-, Y- AND K-JOINTS WITHOUT BACKING
(INCLUDING JOINT GEOMETRY)
• JOINT PREPARATIONS
• DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)
• CLEANLINESS (CONDITION OF STEEL SURFACES)
• TACKING (TACK WELD QUALITY AND LOCATION)
8. CONFIGURATION AND FINISH OF ACCESS HOLES
9. FIT-UP OF FILLET WELDS
• DIMENSIONS (ALIGNMENT, GAPS AT ROOT)
• CLEANLINESS (CONDITION OF STEEL SURFACES) O O
• TACKING (TACK WELD QUALITY AND LOCATION)
10. CHECK WELDING EQUIPMENT
P O
P P
P P
O O
O O
O O
P O
O O
O O
O O
TABLE N5.4-2 INSPECTION TASKS DURING WELDING
1. CONTROL AND HANDLING OF WELDING CONSUMABLES
• PACKAGING
• EXPOSURE CONTROL
2. NO WELDING OVER CRACKED TACK WELDS
3. ENVIRONMENTAL CONDITIONS
• WIND SPEED WITHIN LIMITS
• PRECIPITATION AND TEMPERATURE
4. WPS FOLLOWED
• SETTINGS ON WELDING EQUIPMENT
• TRAVEL SPEED
• SELECTED WELDING MATERIALS
• SHIELDING GAS TYPE/FLOW RATE
• PREHEAT APPLIED
• INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.)
• PROPER POSITION (F, V, H, OH)
5. WELDING TECHNIQUES
• INTERPASS AND FINAL CLEANING O O
• EACH PASS WITHIN PROFILE LIMITATIONS
• EACH PASS MEETS QUALITY REQUIREMENTS
6. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS
O O
O O
O O
O O
O O
P P
TABLE N5.4-3 INSPECTION TASKS AFTER WELDING
1. WELDS CLEANED
2. SIZE, LENGTH AND LOCATION OF WELDS
3. WELDS MEET VISUAL ACCEPTANCE CRITERIA
A. • CRACK PROHIBITION
B. • WELD/BASE-METAL FUSION
C. • CRATER CROSS SECTION
D. • WELD PROFILES
E. • WELD SIZE
F. • UNDERCUT
G. • POROSITY
4. ARC STRIKES
5. k-AREA[a]
6. WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPES[b]
7. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED)
8. REPAIR ACTIVITIES
9. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER
10. NO PROHIBITED WELDS HAVE BEEN ADDED WITHOUT THE APPROVAL OF THE EOR
a. WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN PERFORMED IN THE K-AREA, VISUALLY INSPECT THE WEB K-AREA FOR CRACKS WITHIN 3 IN. (75 MM) OF THE WELD.
b. AFTER ROLLED HEAVY SHAPES (SEE SECTION A3.1C) AND BUILT-UP HEAVY SHAPES (SEE SECTION A3.1D) ARE WELDED, VISUALLY INSPECT THE WELD ACCESS HOLE FOR CRACKS.
a. THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. STAMPS, IF USED, SHALL BE THE LOW-STRESS TYPE.
O O
P P
P P
P P
P P
P P
P P
P P
P P
O O
1. MANUFACTURER’S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS
2. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS
3. CORRECT FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH
IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE)
4. CORRECT BOLTING PROCEDURE SELECTED FOR JOINT DETAIL
5. CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION
AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS
6. PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED
AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED
7. PROTECTED STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER
COMPONENTS
TABLE N5.6-1 INSPECTION TASKS PRIOR TO BOLTING
TABLE N5.6-2 INSPECTION TASKS DURING BOLTING
1. FASTENER ASSEMBLIES PLACED IN ALL HOLES AND WASHERS AND NUTS ARE
POSITIONED AS REQUIRED
2. JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING
OPERATION
3. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING
4. FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION,
PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE
EDGES
TABLE N5.6-3 INSPECTION TASKS AFTER BOLTING
1. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS P P
O P
O O
O O
O O
O O
P O
O O
O O
O O
O O
O O
P P
FIRE-RESISTANT MATERIALS
REQUIRED VERIFICATION AND INSPECTION OF FIRE-RESISTANT MATERIALS
1705.14 SPRAYED FIRE-RESISTANT…