G-006 - PHASING PLAN_Amend7.pdf
PDF 2 MB Posted
- Solicitation number
- W912DS24R0020
About this file
This document is a Phasing Plan for the renovation of Building 120 at Watervliet Arsenal in New York. The plan outlines the construction phases and sequencing required to keep the facility's Box Shop operation and Emergency Responder Radio Equipment fully functional throughout the project. Key details include:
The project will renovate a 102,000 square foot multi-use commercial and industrial building, consolidating a wood shop and general facility maintenance on the ground level, constructing a new lab facility on the second level, and adding new office space on the third level. The work will be completed in two main phases, with specific plans for the Entrance, First, Second, and Third floors, as well as the Roof. Maintaining two means of egress and keeping the Center Stair operational are critical requirements. The General Contractor is responsible for the final phasing plans and construction schedule.
View the file
Other files
Show 40 more
Latest 50 of 59 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEMO & CONSTRUCTION
DEMO & CONSTRUCTION
TEMP BOX SHOP
OPERATION, REF
TO SHEET G-008
PROVIDE PATHWAY
THRU AREA OF
CONSTRUCTION FOR
EGRESS IN HATCH
AREA
ONGOING CONSTRUCTION
TEMP BOX SHOP
OPERATION, REF TO
SHEET G-008
ONGOING CONSTRUCTION
ONGOING CONSTRUCTION
DEMO & CONSTRUCTION
PHASING PLAN NOTES
1. GC IS RESPONSIBLE FOR FINAL PHASING PLANS AND
CONSTRUCTION SCHEDULE.
2. PHASING PLANS ARE FOR INFORMATION ONLY.
3. REFER TO SHEET G-008 FOR CRITICAL BOX SHOP PHASING.
BOX SHOP MUST BE FULLY OPERATIONAL AT ALL TIMES.
4. IT IS ALSO IMPERATIVE THAT THE EMERGENCY RESPONDER
RADIO EQUIPMENT REMAIN ACTIVE THROUGHOUT
CONSTRUCTION.
5. TWO MEANS OF EGRESS IS REQUIRED AT ALL TIMES.
SEQUENCING OF THE STAIR CONSTRUCTION MUST MAINTAIN
(2) STAIRS IN OPERATION AT ALL TIMES.
6. THE CENTER STAIR IS THE ONLY MEANS OF EGRESS FROM THE
ROOF.
AREA UNDER CONSTRUCTION
CONSTRUCTION COMPLETED
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
WVA B120
R T
A S
U B
M
IS
S
IO
N /0
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
A u to d e s k D o c s
/A U
S -0
-U
S A
C E
N
Y W
V A
B ld g R e c a p /A
-W V
A R
.r v t
/1
/2
:0
:3
P
M
G-006
P H
A S
IN
G
P L A
N
W A
T E
R V
L
IE
T A
R S
E N
A L N
Y
N Y
D
IS
T R
IC
T
A R
C A
D
IS
U .S
I N
C
R
O U
T E
S
U
IT
E
C L
IF
T O
N P
A R
K N
Y
E W
R
IG
H T
L L U
B M
C C
A R
T H
Y
E W
R
IG
H T
/0
/2
W D
S F
W D
S D
I D
C -M
R E
C A
P
IT
A L
IZ
A T
IO
N
O F
B U
IL
D
IN
G
B
P R
O J E
C T
N O
W
D
S F
1" = 30'-0"1
ENTRANCE FLOOR PLAN_PHASE 1B
1" = 30'-0"2
FIRST AND MEZANNINE FLOOR
PLAN_PHASE 1B
1" = 30'-0"3
SECOND FLOOR PLAN_PHASE 1B
1" = 30'-0"4
THIRD FLOOR PLAN_PHASE 1B
PHASE 1B
1" = 30'-0"5
ROOF PLAN_PHASE 1B
PHASE 2
1" = 30'-0"6
ENTRANCE FLOOR PLAN_PHASE 2
1" = 30'-0"7
FIRST AND MEZANNINE FLOOR
PLAN_PHASE 2
DEMOLITION AND CONSTRUCTION ON THE ENTRY LEVEL, UNOCCUPIED AREAS OF THE L1, AND THE SOUTH STAIR.
1" = 30'-0"8
SECOND FLOOR PLAN_PHASE 2
1" = 30'-0"9
THIRD FLOOR PLAN_PHASE 2
1" = 30'-0"10
ROOF PLAN_PHASE 2
SOUTH STAIR CONSTRUCTION COMPLETED. ONGOING CONSTRUCTION ON ENTRY LEVEL AND L1. BEGIN CONSTRUCTION
ON L2.
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M D
T
/1
/2
| Sheets |
| G-006 - PHASING PLAN |
File details come from the government source that posted it. Updated .