RTA Drawings Lee Vol 3.pdf
PDF 6 MB Posted
- Solicitation number
- W912DS21B0004
About this file
This document provides details for a federal contract opportunity to repair two barracks buildings at the United States Military Academy at West Point. The project entails full renovation of Building 740 at Lee Barracks and optional full renovation of Building 738 at Sherman Barracks. Building 740 repairs will include interior renovations to address space deficiencies, failing conditions, and MEP systems replacements. Temporary swing space will be required for the barber shop during repairs. A new cadet health clinic will be added. Building 738 repairs are optional and will also address interior and exterior renovations along with MEP system replacements. Hazardous materials abatement will be included. The contract is valued between $100-200 million with a period of performance of approximately 1034 calendar days. The solicitation is expected to be posted on August 6, 2021 on SAM.gov with proposals due around 30 days later. The NAICS code is 236220 and registration on SAM.gov is required to access the solicitation.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE.:
VOLUME:
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
JKJKEWEW
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 2:34:56 PM
G-003A
SWING
SW
IN
G S
PA
C
E C
O
VE
R S
H
EE
T -V
O
LU
M E
TH
R
EE
W
ES
T
PO
IN
T, N Y
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
E R
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
J
U
LY
W
2D S1
7D
RTA SUBMISSION
LE
E
BA
R
R
AC
KS
W
2D S1
8F
NEW YORK DISTRICT
WEST POINT, NY
LEE BARRACKS
W912DS17D0007
23 JULY 2021
PN 81721
PN
SITE MAP PROJECT LOCATION
VICINITY MAP LEE / SHERMAN BARRACKS
BUILDINGS LEE BARRACKS
SWING SPACE
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
JKJKEWEW
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/22/2021 2:35:29 PM
G-001B
LEE
D R
AW
IN
G
IN
D
EX
VO
LU
M
E O
N E
W
ES
T
PO
IN
T, N Y
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
E R
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
J
U
LY
W
2D S1
7D
RTA SUBMISSION
LE
E
BA
R
R
AC
KS
W
2D S1
8F
PN
DRAWING LIST - VOLUME 01
SHEET
NUMBER SHEET NAME
INTERIORS
I-001 INTERIOR FINISH SCHEDULE & GENERAL NOTES
I-002 INTERIOR FINISH SCHEDULE (CONT)
I-003 INTERIOR FINISH SCHEDULE (CONT)
I-100S SUB-BASEMENT FINISH PLAN
I-100SA SUB-BASEMENT FINISH PLAN - PART A
I-100SB SUB-BASEMENT FINISH PLAN - PART B
I-100B BASEMENT FINISH PLAN
I-100BA BASEMENT FINISH PLAN - PART A
I-100BB BASEMENT FINISH PLAN - PART B
I-101 FIRST FLOOR FINISH PLAN
I-101A FIRST FLOOR FINISH PLAN - PART A
I-101B FIRST FLOOR FINISH PLAN - PART B
I-102 SECOND FLOOR FINISH PLAN
I-102A SECOND FLOOR FINISH PLAN - PART A
I-102B SECOND FLOOR FINISH PLAN - PART B
I-103 THIRD FLOOR FINISH PLAN
I-103A THIRD FLOOR FINISH PLAN - PART A
I-103B THIRD FLOOR FINISH PLAN - PART B
I-104 FOURTH FLOOR FINISH PLAN
I-104A FOURTH FLOOR FINISH PLAN - PART A
I-104B FOURTH FLOOR FINISH PLAN - PART B
I-105 FIFTH FLOOR FINISH PLAN
I-105A FIFTH FLOOR FINISH PLAN - PART A
I-105B FIFTH FLOOR FINISH PLAN - PART B
I-200.A BARBER & BEAUTY SHOP FURNITURE LEGEND
I-200.B BARRACKS FURNITURE LEGEND & NOTES
I-200S.1 SUB-BASEMENT FURNITURE SCHEDULE
I-200S.2 SUB-BASEMENT FURNITURE PLAN
I-200SA SUB-BASEMENT FURNITURE PLAN - PART A
I-200SB SUB-BASEMENT FURNITURE PLAN - PART B
I-200B.1 BASEMENT FURNITURE SCHEDULE
I-200B.2 BASEMENT FURNITURE PLAN
I-200BA BASEMENT FURNITURE PLAN - PART A
I-200BB BASEMENT FURNITURE PLAN - PART B
I-201.1 FIRST FLOOR FURNITURE PLAN & FURNITURE SCHEDULE
I-201A FIRST FLOOR FURNITURE PLAN - PART A
I-201B FIRST FLOOR FURNITURE PLAN - PART B
I-202.1 SECOND FLOOR FURNITURE SCHEDULE
I-202.2 SECOND FLOOR FURNITURE PLAN
I-202A SECOND FLOOR FURNITURE PLAN - PART A
I-202B SECOND FLOOR FURNITURE PLAN - PART B
I-203.1 THIRD FLOOR FURNITURE SCHEDULE
I-203.2 THIRD FLOOR FURNITURE PLAN
I-203A THIRD FLOOR FURNITURE PLAN - PART A
I-203B THIRD FLOOR FURNITURE PLAN - PART B
I-204.1 FOURTH FLOOR FURNITURE SCHEDULE
I-204.2 FOURTH FLOOR FURNITURE PLAN
I-204A FOURTH FLOOR FURNITURE PLAN - PART A
I-204B FOURTH FLOOR FURNITURE PLAN - PART B
I-205.1 FIFTH FLOOR FURNITURE SCHEDULE
I-205.2 FIFTH FLOOR FURNITURE PLAN
I-205A FIFTH FLOOR FURNITURE PLAN - PART A
I-205B FIFTH FLOOR FURNITURE PLAN - PART B
I-300.1 SIGNAGE DETAILS
I-300.2 SIGNAGE DETAILS
I-300.3 CHC INTERIOR SIGNAGE
I-300.4 CHC INTERIOR SIGNAGE
I-300.5 CHC INTERIOR SIGNAGE
I-300S SUB-BASEMENT SIGNAGE SCHEDULE
I-300SA SUB-BASEMENT SIGNAGE PLAN - PART A
I-300SB SUB-BASEMENT SIGNAGE PLAN - PART B
I-300B BASEMENT SIGNAGE SCHEDULE
I-300BA BASEMENT SIGNAGE PLAN - PART A
I-300BB BASEMENT SIGNAGE PLAN - PART B
I-301 FIRST FLOOR SIGNAGE SCHEDULE
I-301A FIRST FLOOR SIGNAGE PLAN - PART A
I-301B FIRST FLOOR SIGNAGE PLAN - PART B
I-302 SECOND FLOOR SIGNAGE SCHEDULE
I-302A SECOND FLOOR SIGNAGE PLAN - PART A
I-302B SECOND FLOOR SIGNAGE PLAN - PART B
I-303 THIRD FLOOR - SIGNAGE SCHEDULE
I-303A THIRD FLOOR - SIGNAGE PLAN - PART A
I-303B THIRD FLOOR - SIGANGE PLAN - PART B
I-304 FOURTH FLOOR SIGNAGE SCHEDULE
I-304A FOURTH FLOOR SIGNAGE PLAN - PART A
I-304B FOURTH FLOOR SIGNAGE PLAN - PART B
I-305 FIFTH FLOOR SIGNAGE SCHEDULE
I-305A FIFTH FLOOR SIGNAGE PLAN - PART A
I-305B FIFTH FLOOR SIGNAGE PLAN - PART B
I-400 TYPICAL FLOOR PATTERN PLAN - SUB-BASEMENT
I-401 TYPICAL FLOOR PATTERN PLAN - BASEMENT
I-402 TYPICAL FLOOR PATTERN PLAN - TYP. CORRIDORS & STAIRS
I-403 ENLARGED FLOOR PATTERN PLAN - CADET ROOM & COLLABORATION ROOM
I-404 ENLARGED FLOOR PATTERN PLAN - TOILET ROOMS
I-405 ENLARGED FLOOR PATTERN PLAN - BARBER & BEAUTY SHOP
I-406 ENLARGED FLOOR PATTERN PLAN - CADET HEALTH CLINIC
I-501 MISCELLANEOUS DETAILS
I-502 MISCELLANEOUS DETAILS
DRAWING LIST - VOLUME 01
SHEET
NUMBER SHEET NAME
A-201 NORTH ELEVATION
A-202 SOUTH ELEVATION
A-203 EAST ELEVATION
A-204 WEST ELEVATION
A-301 SITE SECTIONS
A-302 SITE SECTIONS
A-310 BUILDING SECTIONS
A-311 BUILDING SECTIONS
A-312 BUILDING SECTIONS
A-313 BUILDING SECTIONS
A-314 BUILDING SECTIONS
A-400 ENLARGED FLOOR PLANS - CADET ROOMS
A-401 ENLARGED FLOOR PLANS - COLLABORATION ROOM
A-402 ENLARGED FLOOR PLANS - BATHROOM
A-404 ENLARGED FLOOR PLANS - EXTERIOR
A-406 ENLARGED FLOOR PLANS - CHC
A-407 ENLARGED FLOOR PLANS - CHC
A-410 INTERIOR ELEVATIONS - CADET LEVEL
A-411 INTERIOR ELEVATIONS - BATHROOMS
A-412 INTERIOR ELEVATIONS - CADET LEVEL CORRIDORS
A-413 INTERIOR ELEVATIONS - BARBER & BEAUTY SHOP
A-414 INTERIOR ELEVATIONS - BARBER & BEAUTY SHOP
A-415 INTERIOR ELEVATIONS - BARBER & BEAUTY SHOP
A-420 INTERIOR ELEVATIONS - CHC
A-421 INTERIOR ELEVATIONS - CHC
A-422 INTERIOR ELEVATIONS - CHC
A-423 INTERIOR ELEVATIONS - CHC
A-424 INTERIOR ELEVATIONS - CHC
A-425 INTERIOR ELEVATIONS - CHC
A-426 INTERIOR ELEVATIONS - CHC
A-430 WALL SECTIONS
A-431 WALL SECTIONS
A-432 WALL SECTIONS
A-440 WALL SECTIONS - SITE
A-441 WALL SECTIONS - SITE
A-442 SITE ENCLOSURES
A-450 ENLARGED STAIR 01 PLANS & SECTION
A-451 ENLARGED STAIR 02 PLANS & SECTION
A-452 ENLARGED STAIR 03 PLANS & SECTION
A-453 ENLARGED STAIR 04 PLANS & SECTION
A-454 ENLARGED ELEVATOR 01 PLANS & SECTION
A-455 ENLARGED ELEVATOR 02 PLANS & SECTION
A-456 ELEVATOR DETAILS
A-457 ELEVATOR DETAILS
A-460 ENLARGED REFLECTED CEILING PLANS
A-500 STAIR DETAILS
A-501 STAIR DETAILS
A-510 ROOF DETAILS
A-511 ROOF DETAILS
A-512 ROOF DETAILS
A-520 PENTHOUSE DETAILS
A-530 EXTERIOR PLAN DETAILS
A-540 WALL SECTION DETAILS
A-560 PLAN DETAILS
A-570 CEILING DETAILS
A-571 CEILING DETAILS
A-580 INTERIOR DETAILS - CADET
A-590 INTERIOR DETAILS - CHC
A-600 PARTITION TYPES & DETAILS
A-601 PARTITION SCHEDULE & DETAILS
A-610 DOOR SCHEDULE - EXTERIOR, SUB-BASEMENT & BASEMENT
A-611 DOOR SCHEDULE - 1ST, 2ND 3RD, 4TH, 5TH, ROOF
A-612 DOOR TYPES & DETAILS
A-613 DOOR DETAILS
A-614 DOOR DETAILS
A-615 DOOR DETAILS
A-616 DOOR DETAILS
A-620 WINDOW TYPES & SCHEDULE
A-621 EXTERIOR WINDOW DETAILS
A-622 EXTERIOR WINDOW DETAILS
A-623 EXTERIOR WINDOW DETAILS
A-624 EXTERIOR WINDOW DETAILS
A-625 EXTERIOR WINDOW & LOUVER DETAILS
A-630 INTERIOR WINDOW DETAILS
A-640 RAILING TYPES & SCHEDULE
A-650 SUB-BASEMENT EQUIPMENT PLAN - PART A
A-651 SUB-BASEMENT EQUIPMENT PLAN - PART B
A-652 BASEMENT EQUIPMENT PLAN - PART A
A-653 BASEMENT EQUIPMENT PLAN - PART B
A-654 EQUIPMENT/FURNITURE SCHEDULE - CHC
A-655 EQUIPMENT/FURNITURE SCHEDULE - CHC
A-656 EQUIPMENT/FURNITURE SCHEDULE - CHC
A-700 MILLWORK DETAILS - CADET
A-701 MILLWORK DETAILS - CADET
A-702 MILLWORK DETAILS - CADET
A-703 MILLWORK DETAILS - CADET
A-710 MILLWORK DETAILS - BBS
A-711 MILLWORK DETAILS - BBS
A-712 MILLWORK DETAILS - BBS
A-720 MILLWORK DETAILS - CHC
A-721 MILLWORK DETAILS - CHC
A-722 MILLWORK DETAILS - CHC
DRAWING LIST - VOLUME 01
SHEET
NUMBER SHEET NAME
ARCHITECTURAL
A-001 ABBREVIATIONS
A-002 GENERAL SYMBOLS AND NOTES
A-003 MOUNTING HEIGHTS & CLEARANCES
AD100S DEMOLITION SUB-BASEMENT PLAN
AD100SA DEMOLITION SUB-BASEMENT PLAN - PART A
AD100SB DEMOLITION SUB-BASEMENT PLAN - PART B
AD100 DEMOLITION BASEMENT PLAN
AD100A DEMOLITION BASEMENT PLAN - PART A
AD100B DEMOLITION BASEMENT PLAN - PART B
AD101 DEMOLITION FIRST FLOOR PLAN
AD101A DEMOLITION FIRST FLOOR PLAN - PART A
AD101B DEMOLITION FIRST FLOOR PLAN - PART B
AD102 DEMOLITION SECOND FLOOR PLAN
AD102A DEMOLITION SECOND FLOOR PLAN - PART A
AD102B DEMOLITION SECOND FLOOR PLAN - PART B
AD103 DEMOLITION THIRD FLOOR PLAN
AD103A DEMOLITION THIRD FLOOR PLAN - PART A
AD103B DEMOLITION THIRD FLOOR PLAN - PART B
AD104 DEMOLITION FOURTH FLOOR PLAN
AD104A DEMOLITION FOURTH FLOOR PLAN - PART A
AD104B DEMOLITION FOURTH FLOOR PLAN - PART B
AD105 DEMOLITION FIFTH FLOOR PLAN
AD105A DEMOLITION FIFTH FLOOR PLAN - PART A
AD105B DEMOLITION FIFTH FLOOR PLAN - PART B
AD106 DEMOLITION PENTHOUSE FLOOR PLAN
AD106A DEMOLITION PENTHOUSE FLOOR PLAN - PART A
AD106B DEMOLITION PENTHOUSE FLOOR PLAN - PART B
AD107 DEMOLITION ROOF PLAN
AD107A DEMOLITION ROOF PLAN - PART A
AD107B DEMOLITION ROOF PLAN - PART B
AD121 DEMOLITION FIRST FLOOR RCP
AD201 DEMOLITION NORTH ELEVATION
AD202 DEMOLITION SOUTH ELEVATION
AD203 DEMOLITION EAST ELEVATION
AD204 DEMOLITION WEST ELEVATION
AD301 DEMOLITION BUILDING SECTION
AD302 DEMOLITION BUILDING SECTION
AD303 DEMOLITION BUILDING SECTION
AD304 DEMOLITION BUILDING SECTION
AD400 DEMOLITION ENLARGED PLANS
AD401 DEMOLITION ENLARGED SECTIONS
AS100 SITE PLAN
A-100S SUB-BASEMENT FLOOR PLAN
A-100SA SUB-BASEMENT FLOOR PLAN - PART A
A-100SB SUB-BASEMENT FLOOR PLAN - PART B
A-100B BASEMENT FLOOR PLAN
A-100BA BASEMENT FLOOR PLAN - PART A
A-100BB BASEMENT FLOOR PLAN - PART B
A-101 FIRST FLOOR PLAN
A-101A FIRST FLOOR PLAN - PART A
A-101B FIRST FLOOR PLAN - PART B
A-102 SECOND FLOOR PLAN
A-102A SECOND FLOOR PLAN - PART A
A-102B SECOND FLOOR PLAN - PART B
A-103 THIRD FLOOR PLAN
A-103A THIRD FLOOR PLAN - PART A
A-103B THIRD FLOOR PLAN - PART B
A-104 FOURTH FLOOR PLAN
A-104A FOURTH FLOOR PLAN - PART A
A-104B FOURTH FLOOR PLAN - PART B
A-105 FIFTH FLOOR PLAN
A-105A FIFTH FLOOR PLAN - PART A
A-105B FIFTH FLOOR PLAN - PART B
A-106 PENTHOUSE FLOOR PLAN
A-106A PENTHOUSE FLOOR PLAN - PART A
A-106B PENTHOUSE FLOOR PLAN - PART B
A-107 ROOF PLAN
A-107A ROOF PLAN - PART A
A-107B ROOF PLAN - PART B
A-120S SUB-BASEMENT RCP
A-120SA SUB-BASEMENT RCP - PART A
A-120SB SUB-BASEMENT RCP - PART B
A-120B BASEMENT RCP
A-120BA BASEMENT RCP - PART A
A-120BB BASEMENT RCP - PART B
A-121 FIRST FLOOR RCP
A-121A FIRST FLOOR RCP - PART A
A-121B FIRST FLOOR RCP - PART B
A-122 SECOND FLOOR RCP
A-122A SECOND FLOOR RCP - PART A
A-122B SECOND FLOOR RCP - PART B
A-123 THIRD FLOOR RCP
A-123A THIRD FLOOR RCP - PART A
A-123B THIRD FLOOR RCP - PART B
A-124 FOURTH FLOOR RCP
A-124A FOURTH FLOOR RCP - PART A
A-124B FOURTH FLOOR RCP - PART B
A-125 FIFTH FLOOR RCP
A-125A FIFTH FLOOR RCP - PART A
A-125B FIFTH FLOOR RCP - PART B
DRAWING LIST - VOLUME 01
SHEET
NUMBER SHEET NAME
GENERAL
G-001A COVER SHEET - VOLUME ONE
G-001B DRAWING INDEX - VOLUME ONE
G-100S CHC SCOPING DIAGRAM - SUB-BASEMENT LEVEL
G-100B CHC SCOPING DIAGRAM - BASEMENT LEVEL
G-101 CHC SCOPING DIAGRAM - FIRST FLOOR
LIFE SAFETY
LP001 LIFE SAFETY CODE SUMMARY
LP002 CODE COMPLIANCE SITE PLAN
LP100S SUB BASEMENT LIFE SAFETY PLAN
LP100B BASEMENT LIFE SAFETY PLAN
LP101 FIRST FLOOR LIFE SAFETY PLAN
LP102 SECOND FLOOR LIFE SAFETY PLAN
LP103 THIRD FLOOR LIFE SAFETY PLAN
LP104 FOURTH FLOOR LIFE SAFETY PLAN
LP105 FIFTH FLOOR LIFE SAFETY PLAN
CIVIL
C-001 GENERAL NOTES
C-002 GENERAL NOTES, LEGEND AND ABBREVIATIONS
C-101 EXISTING CONDITIONS PLAN - LEE BARRACKS
C-102 BARBER AND BEAUTY SHOP SWING SPACE AREA PLAN
CD101 DEMOLITION PLAN - LEE BARRACKS
CS101 SITE PLAN – LEE BARRACKS
CS102 CONSTRUCTION VEHICLE ACCESS ROUTE PLAN
CS103 PHASE I CONSTRUCTION EXHIBIT - BARBER AND BEAUTY SHOP SWING SPACE AREA
CS104 PHASE II CONSTRUCTION EXHIBIT - LEE & SHERMAN BARRACKS
CS105 PHASE III CONSTRUCTION EXHIBIT - LEE & SHERMAN BARRACKS
CS106 PHASE IV CONSTRUCTION EXHIBIT - LEE & SHERMAN BARRACKS
CS107 PHASE V CONSTRUCTION EXHIBIT - LEE & SHERMAN BARRACKS
CG101 GRADING AND DRAINAGE PLAN - LEE BARRACKS
CG102 SOIL EROSION PLAN - LEE BARRACKS
CU101 UTILITY PLAN – LEE BARRACKS
C-201 NORTH RAMP PLAN AND PROFILE - LEE BARRACKS
C-202 SOUTH RAMP PLAN AND PROFILE - LEE BARRACKS
C-203 STORM DRAINAGE AND SANITARY SEWER PROFILES - LEE BARRACKS
C-204 ELECTRIC DUCT BANK PROFILES - LEE BARRACKS
C-205 WATER MAIN PROFILES - LEE BARRACKS
C-301 NORTH RAMP CROSS SECTIONS - LEE BARRACKS
C-501 CONSTRUCTION DETAILS
C-502 CONSTRUCTION DETAILS
C-503 CONSTRUCTION DETAILS
C-504 CONSTRUCTION DETAILS
C-505 CONSTRUCTION DETAILS
C-506 CONSTRUCTION DETAILS
L-101 LANDSCAPE PLAN - LEE BARRACKS
L-501 LANDSCAPE DETAILS - LEE BARRACKS
STRUCTURAL
S-001 STRUCTURAL GENERAL NOTES
S-002 CONCRETE REPAIR NOTES
SS101 STRUCTURAL SITE PLAN - FIRST FLOOR LEVEL
S-100S SUB-BASEMENT FOUNDATION PLAN
S-100B BASEMENT FLOOR FRAMING PLAN
S-101 FIRST FLOOR FRAMING PLAN
S-102 SECOND FLOOR FRAMING PLAN
S-103 THIRD FLOOR FRAMING PLAN
S-104 FOURTH FLOOR FRAMING PLAN
S-105 FIFTH FLOOR FRAMING PLAN
S-106 MAIN ROOF FRAMING PLAN
S-301 SECTIONS
S-302 SECTIONS
S-303 SECTIONS
S-304 SECTIONS
S-305 UTILITY VAULTS F3, F4 & F8
S-501 TYPICAL DETAILS
S-502 TYPICAL DETAILS
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
JKJKEWEW
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 2:34:53 PM
G-002B
LEE
D R
AW
IN
G
IN
D
EX
VO
LU
M
E
TW
O
W
ES
T
PO
IN
T, N Y
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
E R
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
J
U
LY
W
2D S1
7D
RTA SUBMISSION
LE
E
BA
R
R
AC
KS
W
2D S1
8F
PN
DRAWING LIST - VOLUME 02
SHEET
NUMBER SHEET NAME
E-102 SECOND FLOOR POWER PLAN
E-103 THIRD FLOOR POWER PLAN
E-104 FOURTH FLOOR POWER PLAN
E-105 FIFTH FLOOR POWER PLAN
E-106 ROOF FLOOR POWER PLAN
E-115 ELECTRICAL FLOOR PLANS - STEAM VAULTS
E-120S SUB-BASEMENT LIGHTING RCP
E-120B BASEMENT LIGHTING RCP
E-121 FIRST FLOOR LIGHTING RCP
E-122 SECOND FLOOR LIGHTING RCP
E-123 THIRD FLOOR LIGHTING RCP
E-124 FOURTH FLOOR LIGHTING RCP
E-125 FIFTH FLOOR LIGHTING RCP
E-126 ROOF LIGHTING RCP
E-201 GROUNDING & LIGHTNING PROTECTION SYSTEM - SITE PLAN
E-202 LIGHTNING PROTECTION PLAN - ROOF
E-203 GROUNDING & LIGHTNING PROTECTION SYSTEM RISER DIAGRAM
E-204 GROUNDING & LIGHTNING PROTECTION SYSTEM RISER DIAGRAM
E-210 CONDUIT ROUTING PLAN - SUB BASEMENT LEVEL
E-300 LIGHTING LAYOUT ELEVATIONS
E-401 ENLARGED ELECTRICAL ROOMS
E-402 ENLARGED FLOOR PLANS
E-430 GRANT HALL ALLEY MODIFICATIONS
E-500 ELECTRICAL DETAILS
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL DETAILS
E-510 LIGHTNING PROTECTION DETAILS
E-511 GROUNDING DETAILS
E-512 GROUNDING DETAILS
E-601 ELECTRICAL PRIMARY POWER ONE-LINE DIAGRAM
E-602 ELECTRICAL SECONDARY POWER ONE-LINE DIAGRAM
E-610 ELECTRICAL ROOM POWER RISER DIAGRAM
E-611 ELECTRICAL ROOM POWER RISER DIAGRAM
E-621 MECHANICAL / ELECTRICAL EQUIPMENT COORDINATION SCHEDULE
E-622 MECHANICAL / ELECTRICAL EQUIPMENT COORDINATION SCHEDULE
E-700 LIGHTING FIXTURE SCHEDULE
E-701 LIGHTING CONTROL SEQUENCE OF OPERATIONS
E-702 LIGHTING CONTROL DIAGRAMS AND SCHEMATICS
E-703 LIGHTING CONTROL DIAGRAMS AND SCHEMATICS
E-704 EMERGENCY LUMINAIRE CIRCUITING DIAGRAM
E-710 EMERGENCY POWER OFF SYSTEM
E-800 PANELBOARD SCHEDULES
E-801 PANELBOARD SCHEDULES
E-802 PANELBOARD SCHEDULES
E-803 PANELBOARD SCHEDULES
E-804 PANELBOARD SCHEDULES
E-805 PANELBOARD SCHEDULES
E-806 PANELBOARD SCHEDULES
E-807 PANELBOARD SCHEDULES
E-808 PANELBOARD SCHEDULES
E-809 PANELBOARD SCHEDULES
E-810 PANELBOARD SCHEDULES
E-811 PANELBOARD SCHEDULES
E-812 PANELBOARD SCHEDULES
E-813 PANELBOARD SCHEDULES
TELECOMMUNICATIONS
T-001 TELECOMMUNICATIONS SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
TS101 TELECOM SITE PLAN - LEE BARRACKS
TS102 BASE WIDE PA PARTIAL SITE PLAN
TS501 DETAILS - MAINTENANCE HOLE
TS502 SITE DETAILS
TD101 DEMOLITION SUB-BASEMENT, BASEMENT, FIRST FLOOR TELECOM PLANS
TD102 DEMOLITION SECOND THRU FIFTH FLOOR TELECOM PLANS
TD600 DEMOLITION ONE LINE DIAGRAM - VOICE AND DATA OSP
T-100S SUB-BASEMENT COMMUNICATIONS PLAN
T-100B BASEMENT COMMUNICATIONS PLAN
T-101 FIRST FLOOR COMMUNICATIONS PLAN
T-102 SECOND FLOOR COMMUNICATIONS PLAN
T-103 THIRD FLOOR COMMUNICATIONS PLAN
T-104 FOURTH FLOOR COMMUNICATIONS PLAN
T-105 FIFTH FLOOR COMMUNICATIONS PLAN
T-106 ROOF COMMUNICATIONS PLAN
T-201 RACK AND WALL ELEVATIONS
T-202 CABINET/RACK AND WALL ELEVATIONS
T-203 TELECOM ROOM CABINET/RACK WALL ELEVATIONS
T-401 ENLARGED TELECOM ROOMS - SUB-BASEMENT- SECOND FLOOR
T-402 ENLARGED TELECOM ROOMS - THIRD - FIFTH FLOOR
T-501 DETAILS - WALL OUTLET AND LABELING
T-502 DETAILS - FLOOR OUTLETS
T-503 PATHWAY DETAILS
T-600 VOICE AND DATA OSP ONE-LINE DIAGRAM
T-601 VOICE AND NIPR DATA ONE-LINE DIAGRAM
T-602 WREN AND WAP DATA ONE-LINE DIAGRAM
T-603 ECS, C-DAS, PA AND CLOCK ONE-LINE DIAGRAM
T-604 CHC DATA ONE-LINE DIAGRAM
SECURITY
TY100S SUB-BASEMENT SECURITY PLAN
TY100B BASEMENT SECURITY PLAN
TY101 FIRST FLOOR SECURITY PLAN
TY102 SECOND FLOOR SECURITY PLAN
TY103 THIRD FLOOR SECURITY PLAN
TY104 FOURTH FLOOR SECURITY PLAN
TY105 FIFTH FLOOR SECURITY PLAN
TY106 ROOF SECURITY PLAN
TY501 SECURITY DOOR DETAILS
TY502 SECURITY DETAILS
TY503 CHC SECURITY DETAILS
TY601 SECURITY ONE - LINE DIAGRAMS
DRAWING LIST - VOLUME 02
SHEET
NUMBER SHEET NAME
MH105 FIFTH FLOOR DUCTWORK PLAN
MH105A FIFTH FLOOR PLAN - DUCTWORK - AREA A
MH105B FIFTH FLOOR PLAN - DUCTWORK - AREA B
MH106 ROOF DUCTWORK PLAN
MH106A ROOF DUCTWORK PLAN - PART A
MH106B ROOF DUCTWORK PLAN - PART B
MP120S SUB-BASEMENT PIPING PLAN
MP120SA SUB-BASEMENT PIPING PLAN - PART A
MP120SB SUB-BASEMENT PIPING PLAN - PART B
MP120B BASEMENT PIPING PLAN
MP120BA BASEMENT PIPING PLAN - PART A
MP120BB BASEMENT PIPING PLAN - PART B
MP121 FIRST FLOOR PIPING PLAN
MP121A FIRST FLOOR PIPING PLAN - PART A
MP121B FIRST FLOOR PIPING PLAN - PART B
MP122 SECOND FLOOR PIPING PLAN
MP122A SECOND FLOOR PIPING PLAN - PART A
MP122B SECOND FLOOR PIPING PLAN - PART B
MP123 THIRD FLOOR PIPING PLAN
MP123A THIRD FLOOR PIPING PLAN - PART A
MP123B THIRD FLOOR PIPING PLAN - PART B
MP124 FOURTH FLOOR PIPING PLAN
MP124A FOURTH FLOOR PIPING PLAN - PART A
MP124B FOURTH FLOOR PIPING PLAN - PART B
MP125 FIFTH FLOOR PIPING PLAN
MP125A FIFTH FLOOR PIPING PLAN - PART A
MP125B FIFTH FLOOR PIPING PLAN - PART B
MP126 ROOF PIPING PLAN
MP126A ROOF PIPING PLAN - PART A
MP126B ROOF PIPING PLAN - PART B
MP127 STEAM VAULT F3 NEW WORK
MP128 STEAM VAULT F4 NEW WORK
MP129 STEAM VAULT F8 NEW WORK
M-301 BUILDING SECTIONS
M-302 BUILDING SECTIONS
M-401 ENLARGED PLANS
M-402 ENLARGED PLANS
M-403 ENLARGED PLANS
M-404 ENLARGED PLANS
M-501 HVAC DETAILS
M-502 HVAC DETAILS
M-503 HVAC DETAILS
M-504 HVAC DETAILS
M-505 HVAC DETAILS
M-506 HVAC DETAILS
M-507 HVAC DETAILS
M-601 EQUIPMENT SCHEDULE
M-602 EQUIPMENT SCHEDULE
M-603 EQUIPMENT SCHEDULE
M-604 EQUIPMENT SCHEDULE
M-651 FLOW DIAGRAM
M-652 FLOW DIAGRAM
M-653 FLOW DIAGRAM
M-654 FLOW DIAGRAM
M-655 FLOW DIAGRAM
M-656 FLOW DIAGRAM
M-657 FLOW DIAGRAM
M-658 FLOW DIAGRAM
M-701 CONTROLS
M-702 CONTROLS
M-703 CONTROLS
M-704 CONTROLS
M-705 CONTROLS
M-706 CONTROLS
M-707 CONTROLS
M-708 CONTROLS
M-709 CONTROLS
M-710 CONTROLS
M-711 CONTROLS
M-712 CONTROLS
M-713 CONTROLS
M-714 CONTROLS
M-715 CONTROLS
M-716 CONTROLS
M-717 CONTROLS
M-718 CONTROLS
M-719 CONTROLS
M-720 CONTROLS
M-721 CONTROLS
M-722 CONTROLS
M-723 CONTROLS
M-724 CONTROLS
M-725 CONTROLS
ELECTRICAL
E-001 ELECTRICAL ABBREVIATIONS & DRAWING INDEX
E-002 ELECTRICAL GENERAL NOTES & SYMBOLS
E-003 ELECTRICAL GENERAL SYMBOLS & FEEDER SCHEDULE
ED010 DEMOLITION SITE POWER PLAN
ED100S DEMOLITION SUB-BASEMENT POWER PLAN
ED100B DEMOLITION BASEMENT POWER PLAN
ED101 DEMOLITION FIRST FLOOR POWER PLAN
ED102 DEMOLITION SECOND FLOOR POWER PLAN
ED103 DEMOLITION THIRD FLOOR POWER PLAN
ED104 DEMOLITION FOURTH FLOOR POWER PLAN
ED105 DEMOLITION FIFTH FLOOR POWER PLAN
ED106 DEMOLITION ROOF POWER PLAN
E-010 SITE POWER PLAN - NEW WORK
E-100S SUB-BASEMENT POWER PLAN
E-100B BASEMENT POWER PLAN
E-101 FIRST FLOOR POWER PLAN
DRAWING LIST - VOLUME 02
SHEET
NUMBER SHEET NAME
GENERAL
G-002A COVER SHEET - VOLUME TWO
G-002B DRAWING INDEX - VOLUME TWO
FIRE PROTECTION
F-001 FIRE PROTECTION GENERAL NOTES
FD100S DEMOLITION SUB-BASEMENT FIRE PROTECTION PLAN
FD100B DEMOLITION BASEMENT FIRE PROTECTION PLAN
FD101 DEMOLITION FIRST FLOOR FIRE PROTECTION PLAN
FD102 DEMOLITION SECOND THRU FIFTH FLOOR FIRE PROTECTION PLANS
F-100S SUB BASEMENT FIRE PROTECTION PLAN
F-100B BASEMENT FIRE PROTECTION PLAN
F-101 FIRST FLOOR FIRE PROTECTION PLAN
F-102 SECOND FLOOR FIRE PROTECTION PLAN
F-103 THIRD FLOOR FIRE PROTECTION PLAN
F-104 FOURTH FLOOR FIRE PROTECTION PLAN
F-105 FIFTH FLOOR FIRE PROTECTION PLAN
F-701 FIRE PROTECTION DETAILS
F-702 FIRE PUMP DETAILS
F-703 FIRE PROTECTION RISER
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES
FAD100S DEMOLITION SUB-BASEMENT FIRE ALARM PLAN
FAD100B DEMOLITION BASEMENT FIRE ALARM PLAN
FAD101 DEMOLITION FIRST FLOOR FIRE ALARM PLAN
FAD102 DEMOLITION SECOND THRU FIFTH FLOOR FIRE ALARM PLANS
FA100S SUB BASEMENT FIRE ALARM PLAN
FA100B BASEMENT FIRE ALARM PLAN
FA101 FIRST FLOOR FIRE ALARM PLAN
FA102 SECOND FLOOR FIRE ALARM PLAN
FA103 THIRD FLOOR FIRE ALARM PLAN
FA104 FOURTH FLOOR FIRE ALARM PLAN
FA105 FIFTH FLOOR FIRE ALARM PLAN
FA106 ROOF FIRE ALARM PLAN
FA701 FIRE ALARM DETAILS
FA702 FIRE ALARM RISER
PLUMBING
P-001 PLUMBING GENERAL NOTES
PD100S DEMOLITION SUB-BASEMENT PLUMBING PLAN
PD100B DEMOLITION BASEMENT PLUMBING PLAN
PD101 DEMOLITION FIRST FLOOR PLUMBING PLAN
PD102 DEMOLITION SECOND THRU FIFTH FLOOR PLUMBING PLANS
PD106 DEMOLITION ROOF PLUMBING PLAN
P-100S.D SUB BASEMENT DRAINAGE PLUMBING PLAN
P-100S.S SUB BASEMENT SERVICE PLUMBING PLAN
P-100B.D BASEMENT DRAINAGE PLUMBING PLAN
P-100B.S BASEMENT SERVICE PLUMBING PLAN
P-101 FIRST FLOOR PLUMBING PLAN
P-102 SECOND FLOOR PLUMBING PLAN
P-103 THIRD FLOOR PLUMBING PLAN
P-104 FOURTH FLOOR PLUMBING PLAN
P-105 FIFTH FLOOR PLUMBING PLAN
P-106 ROOF PLUMBING PLAN
P-400 ENLARGED PUMBING PLAN - PLUMBING ROOM SUB BASEMENT
P-401 ENLARGED PLUMBING PLAN-MEN'S & WOMEN'S RESTROOM - LEVEL 1
P-401.CD ENLARGED PLUMBING PLAN - MEN'S & WOMEN'S RESTROOM - CEILING DRAINAGE - LEVEL 1 P-402 ENLARGED PLUMBING PLANS - MEN'S & WOMEN'S RESTROOM-SECOND THRU FIFTH FLOORS P-402.CD ENLARGED PLUMBING PLANS - MEN'S AND WOMEN'S RESTROOM - CEILING DRAINAGE - LEVELS 2 THRU 4
P-500 PLUMBING DETAILS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-602 PLUMBING SCHEDULE
P-700 DOMESTIC WATER RISER DIAGRAM
P-700.1 DOMESTIC WATER RISER DIAGRAM
P-701 NATURAL GAS RISER DIAGRAM
P-702 SANITARY RISER DIAGRAM
P-702.1 SANITARY RISER DIAGRAM
P-703 STORM WATER RISER DIAGRAM
MECHANICAL
M-001 HVAC GENERAL NOTES
M-002 HVAC GENERAL NOTES
M-003 HVAC GENERAL NOTES
M-004 TEMPORARY MOBILE BOILER SITE PLAN
MD100S DEMOLITION SUB-BASEMENT MECHANICAL PLAN
MD100B DEMOLITION BASEMENT MECHANICAL PLAN
MD101 DEMOLITION FIRST FLOOR MECHANICAL PLAN
MD102 DEMOLITION SECOND FLOOR MECHANICAL PLAN
MD103 DEMOLITION THIRD FLOOR MECHANICAL PLAN
MD104 DEMOLITION FOURTH FLOOR MECHANICAL PLAN
MD105 DEMOLITION FIFTH FLOOR MECHANICAL PLAN
MD106 DEMOLITION ROOF MECHANICAL PLAN
MD107 DEMOLITION STEAM VAULT PIPING AND EQUIPMENT
MH100S SUB-BASEMENT DUCTWORK PLAN
MH100SA SUB-BASEMENT DUCTWORK PLAN - PART A
MH100SB SUB-BASEMENT DUCTWORK PLAN - PART B
MH100B BASEMENT DUCTWORK PLAN
MH100BA BASEMENT DUCTWORK PLAN - PART A
MH100BB BASEMENT DUCTWORK PLAN - PART B
MH101 FIRST FLOOR DUCTWORK PLAN
MH101A FIRST FLOOR DUCTWORK PLAN - PART A
MH101B FIRST FLOOR DUCTWORK PLAN - PART B
MH102 SECOND FLOOR DUCTWORK PLAN
MH102A SECOND FLOOR DUCTWORK PLAN - PART A
MH102B SECOND FLOOR DUCTWORK PLAN - PART B
MH103 THIRD FLOOR DUCTWORK PLAN
MH103A THIRD FLOOR DUCTWORK PLAN - PART A
MH103B THIRD FLOOR DUCTWORK PLAN - PART B
MH104 FOURTH FLOOR DUCTWORK PLAN
MH104A FOURTH FLOOR DUCTWORK PLAN - PART A
MH104B FOURTH FLOOR DUCTWORK PLAN - PART B
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
JKJKEWEW
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 2:35:02 PM
G-003B
SWING
D R
AW
IN
G
IN
D
EX
SW
IN
G
S
PA
C E
W
ES
T
PO
IN
T, N Y
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
E R
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
J
U
LY
W
2D S1
7D
RTA SUBMISSION
LE
E
BA
R
R
AC
KS
W
2D S1
8F
PN
DRAWING LIST - VOLUME 03 - SWING SPACE
SHEET
NUMBER SHEET NAME
GENERAL
G-003A SWING SPACE COVER SHEET - VOLUME THREE
G-003B DRAWING INDEX - SWING SPACE
G-004 PERFORMANCE REQUIREMENTS
CIVIL
C-102_ BARBER AND BEAUTY SHOP SWING SPACE AREA PLAN
CS103_ PHASE I CONSTRUCTION EXHIBIT - BARBER AND BEAUTY SHOP SWING SPACE AREA
ARCHITECTURAL
A- 001 ABBREVIATIONS
A- 002 GENERAL SYMBOLS & NOTES
A- 003 MOUNTING HEIGHTS & CLEARANCES
AS101 SITE PLAN - SWING SPACE
A-110 FLOOR PLAN - SWING SPACE TRAILER
A-112 ROOF PLAN - SWING SPACE TRAILER
A-130 REFLECTED CEILING PLAN - SWING SPACE TRAILER
A-210 BUILDING ELEVATIONS - SWING SPACE TRAILER
A-310 BUILDING SECTION - SWING SPACE TRAILER
A-450 ENLARGED FLOOR PLANS - SWING SPACE TRAILER
A-460 ENLARGED ELEVATIONS - SWING SPACE TRAILER
A-620 DOOR, WINDOW, & EQUIPMENT SCHEDULES- SWING SPACE TRAILER
FIRE ALARM
FA101 FIRE ALARM PLAN - SWING SPACE - TRAILER
ELECTRICAL
E-110 POWER PLAN - SWING SPACE - TRAILER
E-450 ENLARGED FLOOR PLANS - SWING SPACE - TRAILER
E-650 ELECTRICAL ROOM POWER RISER DIAGRAM - SWING SPACE - TRAILER
TELECOMMUNICATIONS
TS110 TELECOM SITE PLAN - TRAILER
T-110 SWING SPACE TRAILER PLAN - COMMUNICATIONS
PERFORMANCE REQUIREMENTS FOR EACH ASSEMBLED
TRAILER (SWING SPACE) STRUCTURE
MECH:
THE SWING SPACE SHALL BE EQUIPPED WITH A BASIC
HVAC (HEATING, VENTILATING AND AIR-CONDITIONING)
SYSTEM WHICH SHALL BE CONSTRUCTED IN
ACCORDANCE WITH NYS MECHANICAL CODE.
THE SYSTEM SHALL BE CAPABLE OF MAINTAINING THE
FOLLOWING INDOOR CONDITIONS; 75 DEGREES F/50%
RH DURING THE COOLING SEASON AND 70 DEGREES F
DURING THE HEATING SEASON. NO HUMIDIFICATION
SHALL BE REQUIRED.
EACH SPACE SHALL BE VENTILATED IN ACCORDANCE
WITH NYS MECHANICAL CODE. OFFICE SPACE SHALL
BE 20 CFM OF OUTSIDE AIR PER PERSON. BATHROOMS
SHALL BE EXHAUSTED AT A RATE NOT LESS THAN 75
CFM PER WATER CLOSET/URINAL. BATHROOM
PRESSURIZATION SHALL BE NEGATIVE WITH RESPECT
TO THE TRAILER OCCUPIED AREAS.
ENSURE THAT THE INTERIOR OF THE TRAILER IS
POSITIVELY PRESSURIZED WITH RESPECT TO THE
OUTDOORS.
THERMAL ZONES SHALL ACCOMMODATE THE ACTUAL
SPACE LAYOUT (SEPARATE ZONES FOR INTERIOR AND
EXTERIOR SPACES) AND SHALL NOT EXCEED 900
SQUARE FEET PER ZONE.
FP/FA:
THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTS OF UFC
3-600-01 AND NFPA 72. THE FIRE ALARM SYSTEM
SHALL MONITOR THE FIRE SPRINKLER SYSTEM AND
COMMUNICATE WITH THE RECEIVING STATION USING
AN APPROVED MONACO TRANSMITTER PANEL.
COORDINATE WITH USMA FIRE DEPARTMENT TO
DETERMINE FINAL SIGNAL PROTOCOL. AS
DISCUSSED WITH THE FIRE CHIEF, THE EXISTING
PANEL IN SPELLMAN HALL MAY BE USED FOR THE
SWING SPACE, AND MASS NOTIFICATION FEATURES
ARE NOT REQUIRED.
ELEC:
SEE ELECTRICAL DRAWINGS
PLUMB:
THE SWING SPACE SHALL BE EQUIPPED WITH A BASIC
PLUMBING (DOMESTIC WATER SERVICE, SANITARY)
SYSTEM WHICH SHALL BE CONSTRUCTED IN
ACCORDANCE WITH NYS PLUMBING CODE.
THE SYSTEM SHALL BE CAPABLE OF SUPPLYING
PLUMBING SERVICES TO MAINTAIN PLUMBING FIXTURES
IN SWING SPACE. ADEQUATE WATER PRESSURE SHALL
BE PROVIDED TO OPERATE PLUMBING FIXTURES INSIDE
SWING SPACE. DOMESTIC WATER CROSS CONNECTION
PROTECTION SHALL BE PROVIDED PER NYS PLUMBING
CODE AND HEALTH DEPT. STANDARDS. ISOLATION
VALVES SHALL BE FULL PORT BALL VALVE.
PIPING MATERIAL SHALL BE:
WATER SERVICE:
ABOVE GRADE: K COPPER
UNDERGROUND: K COPPER
SANITARY/VENT SERVICE:
ABOVE GRADE: CAST IRON SOIL PIPE
UNDERGROUND: REFER TO SITE/CIVIL DRAWINGS
REFER TO SITE/CIVIL FOR SANITARY, WATER SERVICE
AND RELATED EARTHWORK.
TRAILER MANF TO PROVIDE HOT WATER HEATER. HOT
WATER HEATER TO ELECTRIC, STORAGE TYPE HOT
WATER HEATER CAPABLE OF MEETING A MINIMUM FIRST
HOUR REQUIREMENT (COMBINED STORAGE AND
RECOVERY) OF 105 GALLONS.
TRAILER MANUFACTURE TO PROVIDE HEAT TRACE ON
DOMESTIC AND SANITARY LINES OUTSIDE THE TRAILER.
TRAILER MANUFATURE TO PROVIDE ELECTRICAL
OUTLET AT LOCATIOIN WHERE WATER LINES EXIT THE
TRAILER.
SINKS AT BARBER STATION TO BE KOHLER MODEL
#K-2867.
TELECOM:
DESIGN MUST PROVIDE COMPLETE TELEPHONE AND
DATA CABLE SYSTEMS FOR THE BUILDING ADDITION.
DESIGN WILL BE PROVIDED AND INSTALLED AS
DESCRIBED HEREIN AND IN ACCORDANCE WITH
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA),
ARMY I3A AND WEST POINT TELECOMMUNICATION
STANDARD.
OUTSIDE/INSIDE PLANT PATHWAY: FURNISH AND
INSTALL CONDUITS AS INDICATED TO AN EXISTING
COMMUNICATIONS MANHOLE MH5A.
OUTSIDE PLANT CABLES: FURNISH AND INSTALL (1)
12-PAIR, #24AWG, PE-89 COPPER CABLE AND (1)
6-STRAND, HIGH GRADE, OUTDOOR RATED,
SINGLE-MODE FIBER OPTIC CABLE WITH DIELECTRIC
STRENGTH MEMBERS FROM THE TRAILER TO B747 VIA
THE NEW/EXISTING UNDERGROUND CONDUITS SYSTEM.
THE UNDERGROUND CONDUIT SYSTEM IS
APPROXIMATE AND MUST BE VERIFIED PRIOR TO
INSTALLATION. THE SINGLE-MODE FIBER MUST MEET
GIGABIT ETHERNET AND 10 GIGABIT ETHERNET
PERFORMANCES.
FURNISH, INSTALL AND TERMINATE EACH 12-PAIR
COPPER CABLE ONTO 12-PAIR PROTECTED BUILDING
ENTRANCE TERMINAL (BET) FULLY POPULATED WITH
GAS TUBE PROTECTOR MODULES AT BOTH ENDS. THE
BET MUST BE EQUIPPED WITH 110 CONNECTOR INPUT
AND OUTPUT, INTERNAL SPLICE CHAMBER AND COVER.
RECOMMEND CIRCA MODEL #1880ECA1. THE
CONTRACTOR MUST STUB-OUT 12-PAIR CABLE TO 110
CROSS CONNECTING BLOCKS AFTER THE BUILDING
ENTRANCE TERMINALS AT BOTH ENDS. GROUNDING
AND BONDING MUST BE DONE IAW NFPA 70, NESC AND
MANUFACTURE PRACTICES.
FURNISH, INSTALL AND TERMINATE 12-STRAND FIBER
OPTIC CABLE AT BOTH ENDS USING 1U CORNING
CLOSET CONNECTOR HOUSING (CCH) PATCH PANEL
WITH COVER AND CCH ST PIGTAILED SPLICE
CASSETTES. FUSION SPLICE MUST BE USED IN THE
PATCH PANEL ASSEMBLY.FURNISH AND INSTALL (1)
STANDARD WALL MOUNTED 24 RU ALUMINUM
EQUIPMENT RACK WITH 19-INCH WIDE MOUNTING
SPACE AND ASSOCIATED HARDWARE IN TRAILER AS
INDICATED. PROVIDE (2) 120V, 20A, QUAD RECEPTACLES
AND (1) 120V, 20A 1U HORIZONTAL RACK MOUNT POWER
STRIP WITH 13 OUTLETS (1 FRONT/12 REAR).
INSIDE PLANT CABLES: FURNISH AND INSTALL
VOICE/DATA OUTLET BOXES IN THE TRAILERS EACH
OUTLET BOX MUST HAVE (3) PLENUM RATED 4-PAIR,
CATEGORY 6 UNSHIELDED TWISTED PAIR (UTP) CABLES
(1 VOICE AND 2 DATA). HOMERUN ALL VOICE AND DATA
CATEGORY 6 CABLES TO THE TELECOMMUNICATIONS
CABINET.
TERMINATE DATA CABLES ONE END ONTO A RJ-45
YELLOW INSERT MODULE IN THE FACEPLATE AT THE
WORKSTATION OUTLET. TERMINATE THE OTHER END
ONTO RACK MOUNTED UNLOADED PATCH PANEL WITH
YELLOW RJ-45 INSERT MODULE..
COLOR CODING OF TELECOMMUNICATIONS FOR
WIRING, OUTLETS AND PATCH PANEL WILL BE AS
FOLLOWS:
DATA - YELLOW
VOICE - GREEN
THE CONTRACTOR MUST CONDUCT ONE WAY OPTICAL
TIME DOMAIN REFLECTOMETER (OTDR) TRACE AT
1310NM AND 1550NM WAVELENGTH. THE CONTRACTOR
MUST PERFORM THE FOLLOWING TESTS ON 12-PAIR
COPPER CABLE:
a. OPENS/SHORTS
b. REVERSED PAIRS
c. CABLE LENGTH
d. INSERTION LOSS
e. NEAR-END CROSSTALK (NEXT) LOSS
f. EQUAL LEVEL FAR-END CROSSTALK (ELFEXT)
g. RETURN LOSS
PROVIDE ALL COPPER AND FIBER TEST RESULTS
(ELECTRONIC COPY) TO NETWORK ENTERPRISE
CENTER (NEC) AFTER THE PROJECT IS COMPLETED.
BUILDING COMPONENTS & GENERAL NOTES:
PROVIDE ALL NECESSARY COMPONENTS AND
SYSTEMS TO
CONFORM TO THE RFP/SOLICITATION, INCLUDING BUT
NOT LIMITED TO:
- PERIMETER FRAME W/ DETACHABLE HITCHES
- FLOOR JOISTS W/ R-19 INSULATION SIZE AS
REQUIRED TO SUPPORT LOADING ON SPANS.
- PLYWOOD DECKING W/ VINYL TILE COVERING
- 2" X 4" EXTERIOR WALL STUDS W/ R-13 INSULATION
- CEMENTITIOUS-PANEL SIDING
- VINYL COVERED GYPSUM INTERIOR WALLS
- SOLID CORE INT. DOORS
- COMMERCIAL STEEL EXT. DOORS W/ PANIC
HARDWARE
& VISION PANELS
- FIXED THERMALLY BROKEN ALUMINUM FRAMED
WINDOWS W/ MINI-BLINDS
- EPDM ROOF COVERING
- SUSPENDED CEILING W/ METAL GRID & LAY-IN
PANELS
- OUTLETS PER ELECTRICAL DRAWINGS
- TOGGLE TYPE SWITCHES
- ADA ½ BATHROOMS W/ POWERED VENT FANS
- EXTERIOR LIGHTING @ DOORS
- EXIT & EMERGENCY LIGHTING
- LAMINATE COUNTERTOP AND CABINETS
ALL NOTES HEREIN MENTIONED AND WITH THOSE ON
THE VARIOUS DRAWINGS SHALL APPLY TO ALL
DRAWINGS AND FORM PART OF THE CONSTRUCTION
CONTRACT.
ALL WORK SHALL CONFORM TO ALL APPLICABLE
FEDERAL, STATE AND LOCAL CODES AND
ORDINANCES HAVING JURISDICTION.
ANY AND ALL DEVIATION FROM THE CONTRACT
DOCUMENTS SHALL REQUIRE WRITTEN APPROVAL
FROM THE ARCHITECT AND OWNER PRIOR TO BEING
EXECUTED BY ANY SUB-CONTRACTOR, VENDOR OR
SUPPLIER.
DO NOT CUT AND/OR PATCH STRUCTURAL WORK IN
SUCH A MANNER RESULTING IN THE REDUCTION IN
LOAD CARRYING CAPACITY. PRIOR APPROVAL FROM
ENGINEER AND/OR ARCHITECT IS REQUIRED.
CONTRACTORS SHALL MAINTAIN PROPER RATINGS
WHEN PENETRATING WALLS, FLOORS AND/OR
CEILINGS IN ALL CIRCUMSTANCES.
COMPLY WITH MANUFACTURERS INSTALLATION
INSTRUCTIONS AND RECOMMENDATIONS TO THE
EXTENT THAT THEY ARE MORE STRINGENT THAN
REQUIREMENTS IN THE CONTRACT DOCUMENTS.
METHOD AND TYPE OF CONSTRUCTION MATERIALS
AND/OR EQUIPMENT SHALL CONFORM TO THE
REQUIREMENTS OF ALL GOVERNING AUTHORITIES.
EQUIPMENT MANUFACTURERS REQUIREMENTS MAY
CHANGE WITH CURRENT UPDATES OR
SUBSTITUTIONS, COORDINATION BY APPLICABLE
TRADES IS REQUIRED.
GYPSUM WALL BOARD IN ALL WET AREAS, IE TOILET
ROOMS, SHOWER
ROOMS, TUB ROOMS, SOILED UTILITY ROOMS,
JANITOR CLOSETS, KITCHENS ETC.,
SHALL BE WATER/MOLD/MOISTURE RESISTANT.
SUBSTITUTE CEMENTITIOUS BACKER BOARD AT ALL
AREAS HAVING CERAMIC TILE WALL FINISH.
CONTRACTOR SHALL FURNISH AND INSTALL ANGLES,
STRUTS, BRACKETS, TOGGLES, EYE BOLTS AND ALL
ACCESSORIES REQUIRED TO PROPERLY SUPPORT
BRACE AND/OR REINFORCE ALL FINISHED FRAMES
AND/OR EQUIPMENT ETC.
CONTRACTOR SHALL CLOSE ALL OPENINGS CREATED
BY MECHANICAL AND ELECTRICAL ETC.
INSTALLATIONS. OPENINGS SHALL BE CLOSED AND
FINISHED TO MATCH EXISTING.
TYPICAL INDICATES THE EXTENT OF WORK TO BE
EXECUTED AS THE SAME USE, LAYOUT,
CONSTRUCTION TYPE AND/OR METHOD.
ALL NEW PIPING AND ELECTRIC CONDUITS SHALL BE
CONCEALED WITHIN NEW PARTITIONS.
EXTERIOR AND INTERIOR TRAILER FINISHES
INCLUDING COLORS, PATTERNS AND FINISH MUST BE
SELECTED BY THE GOVERNMENT POST AWARD FROM
TRAILER MANUFACTURERS STANDARD OFFERING
AND INCLUDES BUT IS NOT LIMITED TO; EXTERIOR
WALLS, DOORS, SUSPENDED CEILING SYSTEM, WALL
FINISHES, FLOOR FINISHES AND WALL BASE. THE
TRAILER MFR MUST ALSO PROVIDED STANDARD
LAMINATE FACED CABINETRY & COUNTERTOP FOR
THE BREAKROOM WHICH THE GOVERNMENT WILL
SELECTED THE FINISHES PER MFR. OFFERING.
SPECIALTY MILLWORK FOR THE BARBER & BEAUTY
SHOP FUNCTIONS MUST BE PROVIDED BY THE
CONTRACTOR AS IDENTIFIED IN THESE DRAWINGS
AND IN THE FINISHES SPECIFIED ON THE DRAWINGS.
STRUCTURAL:
TRAILER MANUFACTURER AND CONTRACTOR REFER TO
S-001 FOR STRUCTURAL DESIGN CRITERIA.
ADDITIONALLY, TRAILER FLOOR FRAMING MUST MEETING
100PSF LIVE LOAD PER TABLE G-1 OF UFC 3-301-01.
TRAILER MANUFACTURER IS RESPONSIBLE FOR A SIGNED
SEALED STRUCTURAL CALCULATION AND DESIGN THAT
INCLUDES BUT NOT LIMITED TO - WIND LOAD, SEISMIC
LOAD, SNOW LOAD, SNOW DRIFT, ANCHORAGE,
STRAPPINGS, HOLD DOWNS, ETC.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/BS-81721A-18-CENTRAL.rvt
7/22/2021 8:30:31 AM
G-004
SWING
P E
R F
O R
M A
N C
E R
E Q
U
IR
E M
E N
T S
W E
S T
P O
IN
T
N
Y J K
A C
J K
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
S
D
S
D
SD
SD
SD
SD SD SD SD SD SD SD SD SD SD
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
SD
SD
SD
SD
SD
SD
C O
M M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
COMM
COMM
COMM
COMM
COMM
COMM
C
O
M
M
C
O
M
M
COMM
COMM
COMM
COMM
COMM
SAN
SAN
SAN
SAN
G
G
G
G
G
G
G
G
G
G
G
G G
G
G G
G G
G
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
S A
N S
A N
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
W W W W W W W W W W W W
X X
X
X
D
D
CB
CB
S
S
SM
D
SM
C
E
S
X X X X X X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X
X X
X X
X X
X X
X
XXXX
E
E
E
T
W W
W W
W W
W W
W W
W W
W
W W W W W W W
CO
X X
X X
X X
X
X X
X
X
X
X
X
X
5.0'
N: 932182.9069
E: 640947.1583
N: 932182.3549
E: 641041.8280
N: 932182.4705
E: 641021.9959
N: 932182.8214
E: 640961.8303
31.5'±
4.0'
(FOR TRAILER
NORTH WALL
ALIGNMENT)
GRANITE CURB
BLDG 745C
PAVERS
GRANITE CURB
P
A
V
E
R
S
P A
V E
R S
MONUMENT
CLOCK
GRANITE CURB
BLDG 747
NININGER HALL
N
G
X
CO
E
S D x
S D x
S D x S
D x
SD
x
SD
x
X X
X
X
X X
X X
X X
X
X
X
X X
X
X X
X X
X X
X
N
1. COORDINATE WITH THE GOVERNMENT FOR
INSTALLATION AND REMOVAL OF BBSSS TRAILERS AND
OTHER IMPROVEMENTS AT THE COMPLETION OF LEE
BARRACKS CONSTRUCTION. UTILITY PRIVATIZATION
CONTRACTOR MUST REMOVE THE ABOVE GROUND
IMPROVEMENTS THAT THEY INSTALLED AND RESTORE
THE AREA. BELOW GRADE IMPROVEMENTS CAN
REMAIN.
1. BARBER AND BEAUTY SHOP SWING SPACE (BBSSS)
TRAILERS.
2. ELECTRIC SERVICE CONNECTION FROM TRANSFORMER
TO (2) UNI-STRUT MOUNTED SWITCHES/BBSSS
TRAILERS (SEE ELECTRICAL PLANS).
3. ELECTRICAL SERVICE EXTENSION FROM EXISTING
ELECTRIC MH TO TRANSFORMER/CONCRETE PAD.
4. 4" WATER SERVICE EXTENSION, VALVE AND STUB.
5. 6" SANITARY SEWER SERVICE EXTENSION AND
CLEAN-OUT.
6. TYPICAL 6' HIGH TEMPORARY CONSTRUCTION FENCE
(C-504/E4)
COORDINATE WITH GOVERNMENT AND ADJUST FENCE
LOCATION TO AVOID CONFLICT WITH BRADLEY
CONSTRUCTION FENCE GATE
(TO BE REMOVED UPON COMPLETION OF SWING SPACE
FIT-OUT).
7. TYPICAL TEMPORARY CONSTRUCTION FENCE (TO
REMAIN UPON COMPLETION OF SWING SPACE FIT-OUT
AND REMOVED WHEN TRAILERS ARE REMOVED)
(C-502/D5).
8. TYPICAL 6' HIGH, TEMPORARY CONSTRUCTION, 12'
WIDE DOUBLE SWING GATE (TO BE REMOVED UPON
COMPLETION OF SWING SPACE FIT-OUT).
9. TYPICAL TEMPORARY CONSTRUCTION, 6' WIDE DOUBLE
SWING GATE (TO REMAIN AND HAVE SLATS REMOVED
UPON COMPLETION OF SWING SPACE FIT-OUT)
(C-502/E8).
10. EXISTING BRADLEY BARRACKS CONSTRUCTION
FENCING (TO REMAIN).
11. COMMUNICATION CONDUITS, (SEE TELECOM PLANS)
12. WATER SERVICE CONNECTION WITH FREEZE
PROTECTION FROM STUB TO TRAILER.
13. SANITARY SEWER CONNECTION FROM CLEAN-OUT TO
TRAILER.
14. AFTER REMOVAL OF BBSSS TRAILERS, MILL EXISTING
PAVEMENT 1
" AND REPAVE WITH NYSDOT HMA
12.5M64 SURFACE COURSE, 1
" THICK. LIMITS MUST BE
A MINIMUM OF 18" BEYOND THE TEMPORARY
CONSTRUCTION FENCE AND AS DEPICTED. 11,000 SF +/-
J C
D P
J K
B A
R B
E R
A
N
B
A
U T
Y
S
H O
P
S
W I N
G
S
P A
C
E
A
P
L A
N
C I V
I L
C-102
N
D A
T E
M A
R K
D E
S C
R I P
T I O
N
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
I S
S U
E
D
A T
E
C O
N T
R A
T
O
S O
L I C
I T
A T
I O
N
N
O
SHEET ID
W D
S F
U S
A
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
US Army Corps of Engineers
N E
W
Y
O R
K
D
I S
T R
I C
T
F
E D
E R
A L
P
L A
Z A
N
W
Y
R
K
N
Y
W D
S D
J U
L
A N
S I
D
W E
I N
T
N
Y
C B
U
E
B
A R
R A
C K
RTA SUBMISSION
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
LEE
A7
SCALE: 1"=40'
A1
BARBER AND BEAUTY SHOP SWING SPACE (BBSSS) SITE IMPROVEMENT PLAN
SCALE: 1"=10'
N
0 10' 20' 40' 80'0
BLDG 745C
BLDG 745 A&B
BLDG 745 A&B
B L D
G
A
B
BLDG 756
BRADLEY BARRACKS
BLDG 756
BRADLEY BARRACKS
BREWERTON ROAD
BLDG 751
PERSHING BKS
BLDG 751
PERSHING BKS
BLDG 747
NININGER HALL
BARBER AND BEAUTY
SHOP SWING SPACE
LOCATION
SHEET KEYNOTES
CURRENT EXISTING CONDITIONS PLAN
BARBER AND BEAUTY SHOP SWING SPACE AREA
SWING
GENERAL SHEET NOTES
AutoCAD SHX Text
GV
V E
R S
C
SITE BENCHMARK
"X" ON BOLT ON HYDRANT
ELEV=162.30'
WH
G
SITE BENCHMARK
"X" ON BOLT ON HYDRANT
ELEV=158.01'
X X
X
STEPS
P L
A N
T E
R
STEPS
S T
E P
S
PAVERS
SALLY PORT
CONCRETE
STEPS
CONCRETE
DUMPSTER
PAVERS
MONUMENT
CLOCK
CONCRETE
PORCH
CONCRETE
BREWERTON ROAD
CONCRETE WALK
CONCRETE WALK
C O
N C
R E
L
K
PLANTER
BLDG 756
BRADLEY BARRACKS
BLDG 756
BRADLEY BARRACKS
BLDG 747
NININGER HALL
BLDG 745C
BLDG 745 A&B
BLDG 745 A&B
B L
G
B
CONCRETE CURB & GUTTER
CONCRETE WALK
C O
N C
R E
T E
R
A
M
P
R
A
M
P
DOCK
CURB CUT
X
X
C
U
T
METAL
PLATE
P A
V E
M E
N T
PAVEMENT
C
O
N
C
R
E
T
E
GRANITE CURB
PAVERS
Pavers
NEW
OLD
GRANITE CURB
GRANITE CURB
P
A
V
E
R
S
SM
D
SM
SM
D
D
D
D
CB
D
CB
CO
D
D
SM
SM
S
S
SM
SM
SM
S
CB
S
S
S
CB
D
CB
S
S
S
D
D
D
S
D
D
D
D
CB
CB
S
CB
S
SM
D
SM
S
D
CB
SM
SM
SM
S
D
CB
S
D
SM
CB
S
S
D
C
BIKE RACK
E
E
S
SM
CB
SM
X
X
X X
Fence
Enclosure with
Gate
T R
E N
C H
D R
A I N
CONCRETE CURB & GUTTER
C
O
N
C
R
E
G
T
T
E
R
CONCRETE CURB & GUTTER
S D x
S D x
S D x S
D x
SD
x
SD
x
BLDG 751
PERSHING BKS
BLDG 751
PERSHING BKS
X X
X X
X X
X X
C
B
D
CB
D
CB
D
S
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X
X
X X X X X
X
X
X X
X X
X X
X X
X X
X X
X X
X
X
X X
XX
T
W W
W W
W W
W W W
CO
X X
X
X
X
X
X
PHASE I-A, TEMPORARY
CONSTRUCTION FENCE BY
CLP FOR UTILITY
INSTALLATION. REMOVE
UPON COMPLETION OF
UTILITY INSTALLATION
X
X X
X
X
X
X X
PHASE I-A, CIRCULATION
ROUTE
PHASE I-B, TYPICAL
TEMPORARY 6' HIGH
CONSTRUCTION FENCE FOR
BARBER AND BEAUTY SHOP
TEMPORARY SWING SPACE
(C-504/E4)
XX
X X
X X
X
X
X
X
X
PAVEMENT MILL AND
OVERLAY AREA AFTER
BBSSS TRAILERS ARE
REMOVED
12' WIDE TYPICAL 6'
HIGH TEMPORARY
CONSTRUCTION
FENCE GATE
TYPICAL TEMPORARY 6'
HIGH CONSTRUCTION
FENCE (C-504/E4)
TYPICAL TEMPORARY
CONSTRUCTION FENCE
(C-502/D5)
N
1. THE USACE TRAILERS MUST BE INSTALLED DURING
PHASE I. SEE DRAWING CS104 FOR LOCATION OF
USACE TRAILERS.
2. ALL TEMPORARY CONSTRUCTION FENCE SINGLE AND
DOUBLE SWING GATES MUST BE PROVIDED WITH
DOUBLE LOCK WITH INTERLOCKING KEYED SYSTEM.
3. PHASE I MUST BE COMPLETE PRIOR TO ANY
DEMOLITION IN LEE BARRACKS.
4. COMPLETE THE FOLLOWING PHASE I IMPROVEMENTS
PRIOR TO PROCEEDING TO PHASE II:
A. BBSSS TRAILER INSTALLATION.
B. ALL UTILITY CONNECTIONS.
C. RELOCATION OF THE EQUIPMENT/FURNISHINGS
REQUIRED FROM LEE BARRACKS TO THE BBSSS
TRAILERS (SEE SHEET AD100SA). PROVIDE 14
DAYS WRITTEN NOTICE TO GOVERNMENT PRIOR
TO EQUIPMENT/FURNISHINGS RELOCATION.
5. SEE LEE BARRACKS DRAWING C-102 FOR ADDITIONAL
CONSTRUCTION RELATED INFORMATION.
LEE AND SHERMAN BARRACKS
PHASE I CONSTRUCTION
BARBER & BEAUTY SHOP SWING
SPACE TRAILERS
J C
D P
J K
B A
R B
A
U T
Y
S
H O
P
S
W I N
G
S
P A
H A
I
O N
S T
R U
C T
I O
N
E
X H
I B
I T
C I V
I L
CS103
N
D A
T E
M A
R K
D E
S C
R I P
T I O
N
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
SHEET ID
W D
S F
U S
A
R M
Y
C
O R
F
E
N G
I N
E E
R S
US Army Corps of Engineers
N E
W
Y
O R
K
D
I S
T R
I C
T
F
E D
E R
A L
P
L A
Z A
N
R
K
N
Y
W D
S D
J U
A N
S I
D
W E
I N
T
N
Y
C B
E
B
A R
R A
C K
RTA SUBMISSION
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
LEE
20' 40'0
A1
PHASE I CONSTRUCTION EXHIBIT - BARBER AND BEAUTY SHOP SWING SPACE AREA
SCALE: 1"=20'
GENERAL SHEET NOTES
SWING
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
DRAWING ABBREVIATIONS
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABRSV ABRASIVE
ABV ABOVE
ACC ACCESSIBLE
ACIP ARCHITECTURAL CAST IN PLACE CONCRETE
ACOUS ACOUSTIC(AL)
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADH ADHESIVE
ADJ ADJACENT
ADJU ADJUSTABLE
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APCONC ARCHITECTURAL PRECAST CONCRETE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT(URAL)
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVB AIR & VAPOR BARRIER
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BG BUMPER GUARD
BHMA BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BITUM BITUMINOUS
BKR BACKER
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BLT IN BUILT-IN
BLW BELOW
BM BEAM
BMK BENCHMARK
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BR BEDROOM
BRCG BRACING
BRG BEARING
BRK BRICK
BRKT BRACKET
BS BOTH SIDES
BSMT BASEMENT
BSPL BACKSPLASH
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
C TO C CENTER TO CENTER
CAB CABINET
CATW CATWALK
CAV CAVITY
CB CATCH BASIN
CBB CEMENTITIOUS (BACKER) BOARD
CBO CONTROL BOX
CBP COMPOSITE BUILDING PANEL
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR CLEAR
CLRM CLASSROOM
CMPTR COMPUTER
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONSTR CONSTRUCTION
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPRS COMPRESSIBLE
CPT CARPET
CR CONTROL ROOM
CRA CRASH RAIL
CS CAST STONE
CSK COUNTER SUNK
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CUB CUBICLE
CUH CABINET UNIT HEATER
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DMPF DAMPROOFING
DN DOWN
DO DITTO
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWL DOWEL
DWR DRAWER
DWTR DUMBWAITER
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EMBMT EMBEDMENT
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER(ING)
ENTR ENTRANCE
EP ELECTRICAL PANEL(BOARD)
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXP EXPANSION
EXP BT EXPANSION BOLT
EXST EXISTING
EXT EXTERIOR
EXT GR EXTERIOR GRADE
EXTR EXTRUDED
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGB FIBERGLASS FACED SILICONE TREATED GYPSUM
CORE SHEATHING BOARD
FGL FIBERGLASS
FH FLAT HEAD
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FLUOR FLUORESCENT
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOW FACE OF WALL
FP FIRE PROTECTION
FPRF FIREPROOF(ED)(ING)
FR FRAME
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSFG FIRE SAFING
FSP FIRE STANDPIPE
FSTNR FASTENER
FT FEET(FOOT)
FTG FOOTING
FTR FINNED TUBE RADIATION
FURG FURRING
FURN FURNITURE
FUT FUTURE
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED
GFGI GOVERNMENT INSTALLED FURNISHED INSTALLED BY
GOVERNMENT
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GL GLASS
GLZ GLAZING
GR FL GROUND FLOOR
GRL GRILLE
GRTG GRATING
GSF GROSS SQUARE FEET
GSKT GASKET
GUT GUTTER
GWB GYPSUM WALLBOARD
GYP GYPSUM
GYP PLAS GYPSUM PLASTER
H ---------------------
H HIGH
HB HOSE BIBB
HC HANDICAPPED
HCT HANDICAPPED ACCESSIBLE TOILET
HDBD HARDBOARD
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HFS HALF FULL SIZE
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HNDRL HANDRAIL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCH
INCL INCLUDING
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
INV INVERT
J ---------------------
JAN JANITOR
J-BOX JUNCTION BOX
JCT JUNCTION
JST JOIST
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
L ---------------------
LAB LABORATORY
LAM LAMINATE(D)(ION)
LAT TIE LATERAL TIEBACK FOR APC PANEL
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC LOCATION
LP LIGHTPROOF
LPT LOW POINT
LT LIGHT
LTG LIGHTING
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH MACHINE
MACH RM MACHINE ROOM
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MBR MEMBER
MC MOISTURE CONTENT
MD METAL DECK
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MEZZ MEZZANINE
MF MILL FINISH
MFR MANUFACTURER
MH MANHOLE
MID MIDDLE
MIFRC MASTIC INTUMESCENT FIRE RESISTIVE COATING
MIL STD MILITARY STANDARD
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MJ MOVEMENT JOINT (IN MASONRY)
MLDG MOLDING (MOULDING)
MLWK MILLWORK
MO MASONRY OPENING
MOD MODIFY
MSCW METAL STUD CURTAIN WALL
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MVBL MOVABLE
MWF MEMBRANE WALL FLASHING
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NF NEAR FACE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NS NEAR SIDE
NSF NET SQUARE FEET
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARALLEL
PASS PASSENGER
PAT PATTERN
PB PUSHBUTTON
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PED PEDESTAL
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PLAT PLATFORM
PLBG PLUMBING
PLG PILING
PLK PLANK
PLYWD PLYWOOD
PNEU PNEUMATIC
PNL PANEL
PNT PAINT
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
R RISER
RAF RAISED ACCESS FLOOR
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOMRECREATION ROOM
RECPT RECEPTACLE
RECT RECTANGULAR
REF REFERENCE
REFR REFRIGERATION
REG REGISTER
REINF REINFORCE(D)(ING)(MENT)
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RET RETURN
REV REVISION
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RJ RUSTICATION JOINT
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
RWC RAIN WATER CONDUCTOR
S --------------------
SAFB SOUND ATTENUATION FIRE BLANKET
SAN SANITARY
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SECT SECTION
SF SQUARE FOOT (FEET)
SFRM SPRAYED FIRE-RESISTANT MATERIAL
SFTWD SOFTWOOD
SGL SINGLE
SHR SHOWER
SHT SHEET(ING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SL SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SPF SPRAY FOAM
SPFI SPRAY POLYURETHANE FOAM INSULATION
SPKR SPEAKER
SPR SPRINKLER
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SERVICE SINK
SST STAINLESS STEEL
SSUR SOLID SURFACING
ST STAIRS
STA STATION
STAG STAGGERED
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SUPT SUPPORT
SURF SURFACE
SUSP SUSPEND
SV SHEET VINYL
SW SIDEWALK
SYM SYMBOL
SYS SYSTEM
T --------------------
T TREAD
T&G TONGUE AND GROOVE
T/S TUB/SHOWER
TA TOILET ACCESSORIES
TB TOWEL BAR
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF STEEL
TOSL TOP OF SLAB
TOW…
This is the start of the file's text. The full file is on GovTribe.