This document provides details on a federal contract opportunity for repair work at two barracks buildings on an Army base. The U.S. Army Corps of Engineers, New York District will issue a solicitation for a firm-fixed price contract to repair Building 740 at Lee Barracks and Building 738 at Sherman Barracks, including interior renovations, mechanical and electrical system replacements, and site work. Renovations at Building 740 will support 192 cadets, while repairs at the optional Building 738 work will support 321 cadets. The solicitation is expected to post on August 6, 2021 with proposals due approximately 30 days later. The period of performance is estimated at 1,034 calendar days. The estimated value of the contract is between $100-200 million. Vendors must register with the System for Award Management to receive the solicitation.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRE ALARM CONTROL PANELFACP
FIRE ALARM ANNUNCIATOR
STROBE POWER EXTENDER
FIRE ALARM TRANSPONDER
MANUAL PULL STATION
ANN
SPE
FTR
F
INTERFACE MODULEIM
HEAT DETECTORR
(HEAT DETECTOR CONTROL FUNCTION)
R - THERMAL, RATE OF RISE
F - THERMAL, FIXED TEMPERATURE
FR - THERMAL, COMBINATION RATE OF RISE PLUS
FIXED TEMPERATURE
SMOKE DETECTORP
(SMOKE DETECTOR CONTROL FUNCTION)
S - AREA SMOKE, IONIZATION
P - SMOKE REFRACTION, PHOTOELECTRIC
D - DUCT MOUNTED, SMOKE IONIZATION
M - MULTI CRITERIA (LIGHT OBSCURATION AND
THERMAL)
A - AUDIBLE BASE
P DUCT SMOKE DETECTOR (PHOTOELECTRIC)
SPEAKER- WALL MOUNTED
SPEAKER- CEILING MOUNTED
STROBE- WALL MOUNTED
CANDELA RATING
(STROBE SHALL BE 15cd U.O.N.)
STROBE- CEILING MOUNTED
CANDELA RATING
(STROBE SHALL BE 15cd U.O.N.)
SPEAKER/STROBE- WALL MOUNTED
CANDELA RATING
(STROBE SHALL BE 15cd U.O.N.)
(XX)
SPEAKER/STROBE- CEILING MOUNTED
(XX) CANDELA RATING
(STROBE SHALL BE 15cd U.O.N.)
FIREFIGHTER PHONE JACK
DOOR HOLDER
SURGE SUPPRESSOR
FLOW DETECTOR/SWITCH
PRESSURE DETECTOR/SWITCH
TAMPER DETECTOR/SWITCH
VALVE WITH TAMPER DETECTOR/SWITCH
(XX)
(XX)
MASS NOTIFICATION TRANSMITTER PANEL TRX
MASS NOTIFICATION CONTROL PANEL
MASS NOTIFICATION STROBE POWER EXTENDER PANEL
MASS NOTIFICATION SPEAKER- WALL MOUNTED
MASS NOTIFICATION SPEAKER- CEILING MOUNTED
MASS NOTIFICATION STROBE- WALL MOUNTED
CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)
MASS NOTIFICATION STROBE- CEILING MOUNTED
CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)
MASS NOTIFICATION SPEAKER/STROBE- WALL MOUNTED
CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)(XX)
MASS NOTIFICATION SPEAKER/STROBE- CEILING MOUNTED
(XX) CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)
TRANSMITTER ANTENNA
(XX)
(XX)
MNS
SPE
M
M
M
M
M
M
M
COMBINATION FIRE ALARM AND MNS SPEAKER WITH
SEPARATE CLEAR FIRE ALARM STROBE AND AMBER MNS
STROBE - WALL MOUNTED
CANDELA RATING 15cd U.O.N. (ACCOUNT FOR DE-RATING
THROUGH AMBER LENS)
(XX)
(XX)
CANDELA RATING 15cd U.O.N. (ACCOUNT FOR DE-RATING
THROUGH AMBER LENS)
F/M
F/M
COMBINATION FIRE ALARM AND MNS SPEAKER WITH
SEPARATE CLEAR FIRE ALARM STROBE AND AMBER MNS
STROBE - CEILING MOUNTED
A ---------------------
A OR AMP AMPERE
ACU AUTONOMOUS CONTROL UNIT
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINIHSED GRADE
AHU AIR HANDLING UNIT
ANN ANNUNCIATOR
ARCH ARCHITECT
ARA AREA OF RESCUE ASSISTANCE
B ---------------------
BKR BREAKER
BFP BACK FLOW PREVENTER
C ---------------------
C OR CDT CONDUIT
C/B CIRCUIT BREAKER
CBL CABLE
CKT CIRCUIT
CL CENTERLINE
CLG CEILING
CO CLEANOUT
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONTR CONTRACTOR
D ---------------------
DEMO DEMOLITION
DIA DIAMETER
DISC DISCONNECT
DIST DISTANCE
DW DOMESTIC WATER
DWG DRAWING
DP DISTRIBUTION PANEL
DSP DRY STANDPIPE
E ---------------------
(E) EXISTING
EC ELECTRICAL CONTRACTOR
ELEC ELECTRICAL
ELEV ELEVATOR
EO ELECTRICALLY OPERATED
EQUIP EQUIPMENT
EX EXISTING
F ---------------------
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
F.B.O. FURNISHED BY OWNER
FD FLOOR DRAIN
FDV FIRE DEPARTMENT VALVE
FDVC FIRE DEPARTMENT VALVE CABINET
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FHR FIRE HOSE RACK
FL. FLOOR
FP FIRE PUMP
FS FLOW SWITCH
FTR FIRE ALARM TRANSPONDER PANEL
FUT FUTURE
G ---------------------
GA GAUGE
GC GENERAL CONTRACTOR
GPM GALLON PER MINUTE
H ---------------------
HP HORSEPOWER
HT HEIGHT
HVAC HEATING, VENTILATING, AIR CONDITIONING
I ---------------------
ID INSIDE DIMENSION
J ---------------------
JB JUNCTION BOX
JUNC JUNCTION
K ---------------------
KW KILOWATT
L ---------------------
LOC LOCAL OPERATING CONSOLE
LT LIGHT
LV LOW VOLTAGE
M ---------------------
MAX MAXIMUM
MCB MAIN CIRCUIT BREAKER
MFR MANUFACTURER
MIN MINIMUM
MNS MASS NOTIFICATION SYSTEM
MTD MOUNTED
N ---------------------
(N) NEW
NAC NOTIFICATION APPLIANCE CIRCUIT
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
O ---------------------
OD OUTSIDE DIAMETER
P ---------------------
PC PLUMBING CONTRACTOR
PIV POST INDICATOR VALVE
PNL PANEL
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PWR POWER
R ---------------------
RE REMOVE EXISTING
RAP REMOTE ANNUNCIATOR PANEL
REQ REQUIRED
GENERAL ABBREVIATIONS
S ---------------------
SIAM SIAMESE
SLC SIGNALING LINE CIRCUIT
SLV SLEEVE
SP STANDPIPE
SPEC SPECIFICATION
SPR SPRINKLER
ST SHUNT TRIP
SPEP STROBE POWER EXTENDER PANEL
STD STANDARD
SW SWITCH
SYS. SYSTEM
T ---------------------
TEL TELEPHONE
TEMP TEMPERATURE
TYP TYPICAL
U ---------------------
U.L. UNDERWRITER'S LABORATORY
U.O.N. UNLESS OTHERWISE NOTED
V ---------------------
V VOLT
VCC VOICE COMMAND CENTER
W ---------------------
W WIRE
WP WEATHERPROOF
WSP WET STANDPIPE
X ---------------------
XDR TRANSDUCER
XMTR TRANSMITTER
XPDR TRANSPONDER
SYMBOLS ---------------------
* DISTANCE DOWN FROM CEILING
+ DISTANCE ABOVE FINISHED FLOOR
FIRE ALARM SYMBOLS
COMBINATION DEVICE SYMBOLS
MASS NOTIFICATION SYMBOLS
BUILDING CONSTRUCTION CODE DATA FINISHED CEILING
REMOTE ANNUNCIATOR
5'
MAX
FACP
6'
MAX
EXIT DOOR
5' MAX
48"
CENTER
FINISHED
FLOOR
MIN.
90"
MIN.
80"
16"
6" MIN.
NOTES: 1. IN MASONRY CONSTRUCTION THE ABOVE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO NEAREST BLOCK OR
BRICK COURSING.
2. THE ABOVE MOUNTING HEIGHTS SHALL BE ADHERED TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE
DRAWINGS OR SPECIFICATIONS.
3. DO NOT INSTALL ANY EQUIPMENT OUTSIDE UNLESS IT IS LISTED FOR OUTDOOR USE.
4. FOR LOW CEILINGS WHERE THE MOUNTING HEIGHTS CAN NOT BE MET, MOUNT THE INDICATING APPLIANCE (EX: SPEAKERS, STROBE) 6" FROM THE CEILING.
5. MOUNT ALL INDICATING APPLIANCES ON THE WALL, UNLESS INDICATED OTHERWISE.
6. ALL DEVICE & APPLIANCE HEIGHTS SHOULD BE CONSISTENT FOR THE ENTIRE PROJECT. THE FIRE PANEL SHALL HAVE A MINIMUM 3 FT CLEARANCE FROM THE FRONT OF THE CONTROL EQUIPMENT & BE LOCATED IN A CLIMATE CONTROLLED AREA.
A C
C E
P T
A B
L E
M O
U N
T
IN
G A
R E
A F
O R
A U
D
IB
L E
A P
P L
IA
N C
E D
IS
T
A N
C E
S A
R E
M E
A S
U R
E D
F R
O M
T H
E T
O P
O F
T H
E A
P P
L
IA
N C
E
A C
C E
P T
A B
L E
M O
U N
T
IN
G A
R E
A F
O R
S
T R
O B
E S
O
R A
U D
IB
L E
/S T
R O
B E
C O
M B
IN
A
T
IO
N A
P P
L
IA
N C
E S
(N
O N
S L E
E P
IN
G
R O
O M
S A
N D
C
R
R
ID
O R
S
D
IS
T A
N C
E S
A R
M
A S
U R
E D
S O
T H
A T
T H
E E
N T
IR
E
L E
U S
T B
E W
IT
H
IN
T
H E
A R
E A
S H
O W
N
ANN
F
GENERAL NOTES
SPEAKER- WALL MOUNTED
SPEAKER- CEILING MOUNTED
CLEAR FIRE ALARM/ MNS STROBE- WALL MOUNTED
CANDELA RATING 15cd U.O.N.
F/M
F/M
F/M
F FIRE ALARM SYSTEM
M MASS NOTIFICATION SYSTEM
CLEAR FIRE ALARM/ MNS STROBE- CEILING MOUNTED
CANDELA RATING 15cd U.O.N.(XX)
F/M
(XX)
STANDARD MOUNTING HEIGHTS
AREA OF REFUGE TWO WAY OF COMMUNICATION CALL BOX
AREA OF REFUGE TWO WAY COMMUNICATION CONTROL
STATION
I A
ARA
MASS NOTIFICATION TRANSMITTER PANEL TRX
AIR SAMPLING SMOKE DETECTOR PANELASSD
POWER SOURCEVPS
KNOX BOXKB
UNINTERRUPTED POWER SUPPLYUPS
AIR SAMPLING SMOKE DETECTOR PORT
LOCAL OPERATING CONSOLELOC
LOC
M A
X
T
H
IG
H
E S
T B
U T
T O
N
ACCEPTABLE
MOUNTING AREA
FOR MANUAL PULL
STATION MEASURED
FROM THE CENTER
OF THE HANDLE
DEMO PLANS - EXISTING CONDITIONS DESIGNATIONS:
EX EXISTING TO REMAIN
RE REMOVE EXISTING
ME MODIFY EXISTING
REX RELOCATE EXISTING
NEW WORK PLANS - EXISTING CONDITIONS DESIGNATIONS:
EX EXISTING TO REMAIN
ME MODIFY EXISTING
ER EXISTING RELOCATED
EXISTING DESIGNATIONS
BUILDING CODE: INTERNATIONAL BUILDING CODE, 2018
FIRE CODE: NFPA 1, FIRE CODE, 2018
SITE LOCATION: WEST POINT, NY
FIRE ALARM SYSTEM: ADDRESSABLE MANUAL VOICE EVACUATION FIRE ALARM/
MASS NOTIFICATION SYSTEM. AUTOMATIC DETECTION.
PROPOSED WORK SHALL COMPLY WITH:
NFPA 70, NATIONAL ELECTRICAL CODE, 2020
NFPA 72, NATIONAL FIRE ALARM CODE, 2019
NFPA 101, LIFE SAFETY CODE, 2018
ICC/ANSI A117.1—10 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, 8 OCTOBER 2019
UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, CHANGE
4, 7 FEBRUARY 2020
UFC 4-101-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS,
12 DECEMBER 2018
UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, CHANGE
1, JANUARY 2010
USACE ECB 2018-17 NEW REQUIREMENTS FOR VISUAL
NOTIFICATION FOR MASS NOTIFICATION SYSTEMS, 14 MAY 2020, REV 1
UFC 4-510-01, DESIGN: MILITARY MEDICAL FACILITIES
FACP/
ACU
FIRE ALARM CONTROL PANEL/ AUTONOMOUS CONTROL UNIT
CARBON MONOXIDE DETECTOR
FIRE ALARM AMPLIFIERAMP
1. DRAWING NOTES ARE INDICATED ON PLANS BY SYMBOL
2. REFER TO HVAC MECHANICAL DRAWINGS FOR EXACT LOCATION OF DUCT SMOKE DETECTORS IN AIR HANDLING UNIT.
3. REFER TO SPRINKLER DRAWINGS FOR EXACT LOCATION AND QUANTITY OF SUPERVISED VALVES AND FLOW SWITCHES.
4. SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES INCLUDING NFPA 72-2019, UFC-3-600-01, AND UFC 4-021-01.
5. LOCATE SMOKE DETECTORS MINIMUM 36 INCHES FROM HVAC DIFFUSERS.
6. LOCATE VISUAL DEVICES A MINIMUM OF 80" ABOVE FINISHED FLOOR OR 6" BELOW THE FINISHED CEILING, WHICHEVER IS LOWER. THE MAXIMUM
MOUNTING HEIGHT IS 96" ABOVE FINISHED FLOOR.
7. VISUAL DEVICE CANDELA RATING SHALL BE AS INDICATED ON DRAWING.
8. INSTALL ALL WIRING IN MINIMUM 3/4" CONDUIT.
9. ALL DEVICES ARE TO BE PROTECTED DURING CONSTRUCTION.
10. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED DEVICES/APPLIANCES.
11. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE
RECORD DRAWINGS.
12. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE
WORK SHOWN.
13. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. ALL CHANGES SHALL
BE CLEARLY INDICATED ON THE RECORD DRAWINGS.
14. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION.
15. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT.
16. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER.
17. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED TECHNICAL REPRESENTATIVE.
18. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST.
ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER.
19. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT
WORK IS NOT ACTIVELY BEING PERFORMED.
20. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC.
21. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC).
22. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN
ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE.
23. FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUMS, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP.
24. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN
SHAFTS SHALL BE TYPE FPLR.
25. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS.
26. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 ARTICLES
760, 770, 725 AND 800 WHERE APPLICABLE.
27. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS.
28. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT.
29. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING.
30. MAINTAIN 40 PERCENT MAXIMUM CONDUIT FILL RATIO AS PER NEC REQUIREMENTS.
31. DEMOLISH ALL EXISTING FIRE ALARM AND MASS NOTIFICATION EQUIPMENT AS SHOWN ON DEMOLITION PLANS. ADDITIONALLY, REMOVE THE EXISTING FIRE ALARM RADIO ALARM TRANSCEIVER ANTENNA FROM THE ROOF OF THE BUILDING. PACKAGE ALL FIRE ALARM SYSTEM CONTROL
EQUIPMENT AND TURN OVER TO THE CONTRACTING OFFICER FOR SPARE PART STOCK.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
FA001
LEE
F
IR
E A
L A
R M
G E
N E
R A
L N
O T
E S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
T A
W
P C
K
C N
M
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
IS
S U
E D
B Y
A M
E N
D M
E N
T
/2
/2
IS
S U
E D
B Y
A M
E N
D M
E N
T
/0
/2
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
PP
P
P
P
PP
P
P
P
P P
P P
P P P P P
P
P
P P P
P
PPP
P P P P P P
P
P
P
P
PP
P
P P
P
S P
E
S P
E
P
IM
IM
IM
IM
P
IM
P
FF
15 15
IM
IM IM IMIM
IM IM IMIM
PF
P
IM
P
IM
IM
IM
R
W P
1 2 3 4 5 6 7 8 109 11 12 13 14
G
G'
J
K
L
FIRE PUMP ROOM
LB001
STAIR 2
LS-B-2
ELEV. 1
LE-B-1
STAIR 1
LS-B-1
ELECTRICAL
LC004
TEAM ROOM 1 - WKTM1
LC040
STAFF TOILET - TLTU1
LC002
SCREENING / TRIAGE
ROOM EXRG4
LC030
LABORATORY - LBPC1
LC015b
BLOOD DRAW - LBVP1
LC015a
PATIENT TOILET -
TLTU1
LC007
SCREENING / TRIAGE
ROOM EXRG4
LC032
SPECIALTY ROOM
EXRG1
LC034
EXAM ROOM EXRG1
LC036
EXAM ROOM EXRG1
LC038
STAFF LOUNGE - SL001
LC018
STAFF TOILET - TLTU1
LC020
OBSERVATION /
HYDRATION - OOHR1
LC028b
ELEVATOR 2
LE-B-2
WAITING ANCILLARY
SERVICES
LC01c
MECHANICAL
L001a
EXAM ROOM EXRG1
LC039
EXAM ROOM EXRG1
LC037
EXAM ROOM EXRG1
LC035
EXAM ROOM EXRG1
LC033
EXAM ROOM EXRG1
LC031
WAITING ROOM
LC01d
CIRCULATION
LC03
CIRCULATION
LC02
ISOLATION EXRG6
LC011a
CHC STAIR 4
LS-B-4
TEAM ROOM 2 - WKTM1
LC005
TOILET TLTU1
LC011b
HEIGHT / WEIGHT
LC010
CONSULT
(BH/NUTRITION) OFDC2
LC008
AED - RCA01
LC016
SPECIMEN TOILET -
TLTU1
LC017 RECEPTION
LC012a
APPOINTMENT CLERK
LC012b
TREATMENT/IMMUNIZATION
- TRGM1/OPIR1
LC029
NURSE STATION -
NSTA1
LC028a
OFFICE NCOIC / CNOC -
OFA05
LC023
OFFICE OIC/CHIEF -
OFA04
LC024
OFFICE CARE
COORDINATOR - OFA04
LC021
CADET SURGEON -
OFA04
LC022
OFFICE CARE
COORDINATOR- OFA04
LC025
CONFERENCE ROOM -
CRA01
LC026
EVS JANC1
LC027
OFFICE TBI RESEARCH
ANALYST - OFA05
LC019 TOILET TLTU1
LC014
COPY SUPPLY RPR01
LC12c
SOILED LINEN - USCL1
LC009
TEAM ROOM 3-4 -
WKTM1
LC001
EQUIPMENT STORAGE -
SRE01
LC003
CLEAN - UCCL1
LC006
A M
P
A M
P
M
ELEVATOR MACHINE
ROOM
L001b
X5
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PLAN NORTH
FA100B
LEE
B A
S E
M E
N T
F
IR
E A
L A
R M
P L A
N
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
T A
W
P C
K
C N
M
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
DRAWING NOTES
1 COORDINATE QUANTITY & LOCATION OF DUCT DETECTORS WITH MECHANICAL CONTRACTOR
(TYP). DUCT DETECTORS ASSOCIATED WITH FIRE/SMOKE DAMPERS TO BE PROVIDED WITH
REMOTE TEST STATIONS. IF POSSIBLE COLLOCATE REMOTE TEST STATIONS. COORDINATE
LOCATION AND QUANTITY OF REMOTE TEST STATIONS WITH MECHANICAL CONTRACTOR (TYP.).
2 PROVIDE 4 ADDRESSABLE INTERFACE MODULES FOR FIRE PUMP SUPERVISION. PROVIDE IN
ACCORDANCE WITH NFPA72 & NFPA20.
3 PROVIDE SMOKE DETECTOR TO INITIATE ELEVATOR RECALL. MACHINE ROOM DETECTOR AND
ELEVATOR LOBBY DETECTORS TO INITIATE ELEVATOR RECALL, AND SHALL CAUSE THE FIRE
FIGHTER'S SERVICE VISUAL SIGNAL TO FLASH IN ANY ELEVATOR CAB THAT SERVES THE
AFFECTED LOBBY.
4 PROVIDE SPE PANEL AND AMP PANELS AS REQUIRED FOR FIRE ALARM AND MASS NOTIFICATION
SYSTEM.
5 PROVIDE 5 ADDRESSABLE INTERFACE MODULES FOR ELEVATOR FUNCTIONS. PROVIDE IN
ACCORDANCE WITH NFPA72 & NFPA20.
6 PROVIDE MONITORING FOR FLOW SWITCH AND SUPERVISED TAMPER SWITCH SERVING
ELEVATOR MACHINE ROOM SPRINKLER(S). FLOW SWITCH SHALL SHUNT POWER TO ELEVATORS
SERVED BY MACHINE ROOM AND HAVE NO TIME DELAY. COORDINATE WITH FIRE SPRINKLER
WORK.
7 SUPERVISED TAMPER SWITCH FOR SPRINKLER SYSTEM CONTROL VALVE.
8 SUPERVISED FLOW SWITCH FOR FLOOR ZONE CONTROL ASSEMBLY.
1/8" = 1'-0"1
BASEMENT FIRE ALARM PLAN
IS
S U
E D
B Y
A M
E N
D M
E N
T
/2
/2
IS
S U
E D
B Y
A M
E N
D M
E N
T
/0
/2
SPE
P
15 15
P
P P
P
P
P
P
P
P P
P P
P
P
P
P
P
P P
P
P
P
P
P P
PP
PP
P
PP
P
P P
P P
P P
P
F
P
PP
FACP
P
P
P
P
IM
F
F
F
30 30
IM
IM
SPE
P
IM
IM
IM
IM
IM
P
WP
WP
WP
1 2 3 4 5 6 7 8 109 11 12 13 14
G
G'
J
K
L
TOILET
LCS11
TOILET
LCS10
EYE LANE - EYEL1
LCS08
HEARING BOOTH -
PEHS2
LCS05
WAITING ROOM -
WRC01
LCS04
PLUMBING
LS01b
TELECOM
LS05
PLUMBING CLEAN OUT
ROOM
LB001c
STORAGE
LS07
VESTIBULE - LOB02
LS09
CIRCULATION
LCS001
STAIR 2
LS-S-2
ELEVATOR 1
LE-S-1
STAIR 1
LS-S-1
BEAUTY STORAGE
LB010
BEAUTY SHOP
LB003
LAUNDRY
LB009 AIR/VAC
LB001d
JANITOR CLOSET
LS06
BARBER SHOP
LB001a
CHC STAIR 4
LS-S-4
ELEVATOR 2
LE-S-2
OFFICE
LB004
CLINIC PHARMACY -
PHOD1
LCS01
EXIT PASSAGE
LCS002CIRCULATION
LCS003
MECHANICAL
LS03
BARBER STORAGE
LB001e
ELECTRICAL
LS02
EYE VISION SCREENING
DISPENSING - EYVS1
LCS07
STORAGE
LCS09
RECEPTION
LCS02
WHEELCHAIR ALCOVE
LCS06
KIOSK - CLSC1
LCS04b
AED - RCA01
LCS03
STAFF LOUNGE
LB005
CHECK-IN KIOSKS
LB002
STAFF SUPPORT
LB01
MIXING
LB008
VENDING AREA
LS04
VESTIBULE
LS10
STORAGE
LB001b
APRON & COAT HOOKS
LB001f
ROOF ACCESS STAIR 3
LS-S-3
TRX
FACP/
ACU
M
AMP
AMP
WOMEN'S ROOM
LB006
11 9
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PLAN NORTH
FA100S
LEE
S U
B B
A S
E M
E N
T F
IR
E
A L A
R M
P L A
N
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
T A
W
P C
K
C N
M
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"1
SUB BASEMENT FIRE ALARM PLAN
DRAWING NOTES
1 ADDRESSABLE CONTROL MODULE FOR ACTIVATION OF SMOKE DAMPER. SMOKE DAMPER MUST CLOSE UPON ACTIVATION OF ANY SPOT TYPE SMOKE DETECTOR LOCATED WITHIN A SPACE SERVED BY THE ASSOCIATED DUCT WORK. REFER TO MECHANICAL DRAWINGS FOR DUCT WORK AND AIR DIFFUSER LOCATIONS. PROVIDE A REMOTE INDICATOR LIGHT VISIBLE FROM FLOOR LEVEL TO INDICATE WHEN THE CONTROL MODULE IS ACTIVATED AND THE DAMPER IS CLOSED.
2 PROVIDE SMOKE DETECTOR TO INITIATE ELEVATOR RECALL. MACHINE ROOM DETECTOR AND ELEVATOR LOBBY DETECTORS TO INITIATE ELEVATOR RECALL, AND SHALL CAUSE THE FIRE FIGHTER'S SERVICE VISUAL SIGNAL TO FLASH IN ANY ELEVATOR
CAB THAT SERVES THE AFFECTED LOBBY.
3 PROVIDE SPE PANEL AND AMP PANELS AS REQUIRED FOR FIRE ALARM AND MASS NOTIFICATION SYSTEM.
4 FIRE ALARM CONTROL PANEL WITH REMOTE MIC.
5 PROVIDE MONITORING FOR FLOW SWITCH AND SUPERVISED TAMPER SWITCH SERVING ELEVATOR MACHINE ROOM SPRINKLER(S). FLOW SWITCH SHALL SHUNT POWER TO ELEVATORS SERVED BY MACHINE ROOM AND HAVE NO TIME DELAY.
COORDINATE WITH FIRE SPRINKLER WORK.
6 TYPICAL LOC SHALL HAVE A REMOTE MICROPHONE THAT EMULATES THE OPERATING OF THE ACU, INDIVIDUAL PUSHBUTTONS ACTIVATING THE MNS PRERECORDED MESSAGES, AND MANUAL ACTIVATION OF AHU SHUTDOWN. PROVIDE TAMPER
PROTECTION. ENCLOSURES THAT CAN BE ONLY BE OPENED BY A KEY SHALL NOT BE USED.
7 PROVIDE A CONTROL MODULE TO OVERRIDE PUBLIC ADDRESS SYSTEM WHEN A FIRE ALARM OR MASS NOTIFICATION SYSTEM
MESSAGE IS ACTIVE.
8 CIRCUIT FROM THE CENTRAL GUARD ROOM (CGR) LOCATED IN EISENHOWER HALL SHALL BE ROUTED THROUGH THIS ROOM THROUGH THE TELECOMMUNICATIONS DUCTBANK. ROUT CIRCUIT TO THE FIRE ALARM / MASS NOTIFICATION CONTROL PANEL AND CONNECT TO THE TELEPHONE PORT. THIS CONNECTION IS PROVIDED TO RECEIVE ANNOUNCEMENTS FROM THE CGR
WHICH WILL BE TRANSMITTED OVER THE MNS SPEAKER SYSTEM.
9 SUPERVISED TAMPER SWITCH FOR STANDPIPE RISER CONTROL VALVE.
10 SUPERVISED FLOW SWITCH FOR FLOOR ZONE CONTROL ASSEMBLY.
11 SUPERVISED TAMPER SWITCH FOR SPRINKLER SYSTEM CONTROL VALVE.
IS
S U
E D
B Y
A M
E N
D M
E N
T
/2
/2
IS
S U
E D
B Y
A M
E N
D M
E N
T
/0
/2
P P
P
P
P
P
P P P P P
P
P
P P P P P P
P
P
P
1515 15
30 30 30
FF
A N
N
IM
IM
IM
P
IM
IM
IM
R
IM
IM
IM
IM
IM
IM
IM
IM
S P
E
S P
E
W P
W P
WP
1 2 3 4 5 6 7 8 109 11 12 13 14
G
G'
J
K
L
STAIR 2
LS-1-2
ELEV.
LE-1-1
STAIR 1
LS-1-1
ELEC.
L102
VESTIBULE
L103
VESTIBULE
L108 STORAGE
L107
MAIN TELECOM - CHC
L110A
TRUNK ROOM
L114
MAIN TELECOM -
CADET
L110B
EQUIPMENT CLEANING
AREA
L109
JANITORS BREAK
ROOM
L101a
CORRIDOR
L100
TRUNK ROOM
L111
WOMEN'S ROOM
L106
MEN'S ROOM
L105
STORAGE
L104
TAC SUPPORT
L113
JANITOR'S OFFICE
L101b
M
X5
ELEVATOR MACHINE
ROOM
L112
A M
P
A M
P
2 2
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PLAN NORTH
FA101
LEE
F
IR
S T
F L O
O R
F
IR
E A
L A
R M
P L A
N
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
T A
W
P C
K
C N
M
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
DRAWING NOTES
1 PROVIDE SMOKE DETECTOR TO INITIATE ELEVATOR RECALL. MACHINE
ROOM DETECTOR AND ELEVATOR LOBBY DETECTORS TO INITIATE
ELEVATOR RECALL, AND SHALL CAUSE THE FIRE FIGHTER'S SERVICE
VISUAL SIGNAL TO FLASH IN ANY ELEVATOR CAB THAT SERVES THE
AFFECTED LOBBY.
2 ADDRESSABLE CONTROL MODULE FOR ACTIVATION OF SMOKE DAMPER.
SMOKE DAMPER MUST CLOSE UPON ACTIVATION OF ANY SPOT TYPE
SMOKE DETECTOR LOCATED WITHIN A SPACE SERVED BY THE
ASSOCIATED DUCT WORK. REFER TO MECHANICAL DRAWINGS FOR DUCT
WORK AND AIR DIFFUSER LOCATIONS. PROVIDE A REMOTE INDICATOR
LIGHT VISIBLE FROM FLOOR LEVEL TO INDICATE WHEN THE CONTROL
MODULE IS ACTIVATED AND THE DAMPER IS CLOSED.
3 PROVIDE SPE PANEL AND AMP PANELS AS REQUIRED FOR FIRE ALARM
AND MASS NOTIFICATION SYSTEM.
4 FIRE ALARM ANNUCIATOR PANEL W/ REMOTE MIC.
5 TYPICAL LOC SHALL HAVE A REMOTE MICROPHONE THAT EMULATES THE
OPERATING OF THE ACU, INDIVIDUAL PUSHBUTTONS ACTIVATING THE
MNS PRERECORDED MESSAGES, AND MANUAL ACTIVATION OF AHU
SHUTDOWN. PROVIDE TAMPER PROTECTION. ENCLOSURES THAT CAN BE
ONLY BE OPENED BY A KEY SHALL NOT BE USED.
6 PROVIDE 5 ADDRESSABLE INTERFACE MODULES FOR ELEVATOR
FUNCTIONS. PROVIDE IN ACCORDANCE WITH NFPA72 & NFPA20.
7 PROVIDE MONITORING FOR FLOW SWITCH AND SUPERVISED TAMPER
SWITCH SERVING ELEVATOR MACHINE ROOM SPRINKLER(S). FLOW
SWITCH SHALL SHUNT POWER TO ELEVATORS SERVED BY MACHINE
ROOM AND HAVE NO TIME DELAY. COORDINATE WITH FIRE SPRINKLER
WORK.
8 SUPERVISED TAMPER SWITCH FOR SPRINKLER SYSTEM CONTROL VALVE.
9 SUPERVISED FLOW SWITCH FOR FLOOR ZONE CONTROL ASSEMBLY.
1/8" = 1'-0"1
FIRST FLOOR FIRE ALARM PLAN
IS
S U
E D
B Y
A M
E N
D M
E N
T
/2
/2
IS
S U
E D
B Y
A M
E N
D M
E N
T
/0
/2
DRAIN TO OUTSIDE
GRADE
PACK ANNULAR SPACE WITH
WATERTIGHT SEALING SYSTEM,
CAULK BOTH SIDES
STORZ FIRE
DEPARTMENT
CONNECTION
EXTERIOR WALL (SEE
ARCHITECTURAL
DRAWINGS FOR
CONSTRUCTION)
TO SYSTEM
MAIN
COLLAR OR
FRICTION
CLAMP TO SECURE
RISER IN-PLACE
CHECK VALVE
AUTOMATIC
BALL DRIP
4 FT.
MIN. CEILING
ESCUTCHEON
18" TO 48"
(SEE ARCH.
DWGS FOR
EXACT HEIGHT)
DETAIL NOTES:
1. 24 INCHES MINIMUM IN ACCORDANCE WITH WATERFLOW DETECTION DEVICE MANUFACTURER
2. 6 TO 24 INCHES MINIMUM DEPENDING UPON WATERFLOW DETENTION DEVICE MANUFACTURER
3. PIPE AND VALVE CONNECTIONS SHOWN ARE DIAGRAMATIC. REFER TO SPECS FOR ALLOWABLE
CONNECTION TYPE.
FLOOR
SELF CONTAINED
TEST & DRAIN
ASSEMBLY
UNION
1 1/2"
STANDPIPE TEE
6" X 6" X 2 1/2"
2-1/2" X 4" NIPPLE
2-1/2" HOSE ANGLE VALVE
STANDPIPE RISER
DRAIN RISER
1 2
FLOOR CONTROL VALVE
SWING CHECK VALVE
PRESSURE GAUGE
WATER FLOW SWITCH
THREAD-O-LET
60"
7' - 6"
MIN.
NOTES:
1. WHEN ARM OVER IS MORE THEN 24"
INCHES IN LENGTH, THE ARM OVER
MUST BE SUPPORTED WITH A PIPE
HANGER.
2. CONNECT ALL ARM-OVERS TO THE
TOP THE BRANCH LINE PIPING.
BOTTOM OF DECK
NIPPLE AS
REQUIRED
BRANCH
SUPPLY LINE
CEILING
TEE 1" SUPPLY LINE
REDUCER AS REQUIRED
CONCEALED SPRINKLER
HEAD HOUSING
CONCEALED SPRINKLER
HEAD
SPRINKLER HEAD (SEE
SPRINKLER SCHEDULE
AND DRAWINGS FOR
TYPE)
SPRINKLER BRANCH
SIZE VARIES
1" PIPING TO NEW
CEILING ELEV. AND LOC.
1" x 1/2" REDUCER
BACKFLOW
PREVENTER
FLANGED OS&Y
VALVE WITH
TAMPER
SWITCH
1'-0" TO 4'-0"
ABOVE FLOOR
FLOOR
ADJUSTABLE PIPE SADDLE WITH
PIPE NIPPLE ATTACHED TO
STEEL BASE STAND, AND
CONCRETE PIER OR STEEL
SUPPORT
DIRECTION OF FLOW
INDICATING VALVE WITH
TAMPER SWITCH SIZED
AS SHOWN ON PLANS
MAIN DRAIN
UPSTREAM GUAGE
RISER CHECK VALVE
DOWNSTREAM GAUGE
FLOW SWITCH
TO SPRINKLER SYSTEM
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F-701
LEE
F
IR
E P
R O
T E
C T
IO
N
D E
T A
IL
S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
T A
W
P C
K
C N
M
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
NTS1
WALL MOUNTED STORZ FIRE
DEPARTMENT CONNECTION
NTS2
TYPICAL SPRINKLER FLOOR CONTROL
VALVE ASSEMBLY AND RISER
NTS3
CONCEALED SPRINKLER HEAD
NTS5
UPRIGHT SPRINKLER HEAD
NTS7
BACKFLOW PREVENTER
NTS8
RISER CHECK VALVE ASSEMBLY
IS
S U
E D
B Y
A M
E N
D M
E N
T
/2
/2
IS
S U
E D
B Y
A M
E N
D M
E N
T
/0
/2
FIRE ALARM AND MASS NOTIFICATION CONTROL PANEL
FIRE ALARM ANNUNCIATOR
STROBE POWER EXTENDER
FIRE ALARM TRANSPONDER
MANUAL PULL STATION
ANN
SPE
FTR
F
INTERFACE MODULEIM
HEAT DETECTORR
(HEAT DETECTOR CONTROL FUNCTION)
R- THERMAL, RATE OF RISE
F- THERMAL, FIXED TEMPERATURE
FR- THERMAL, COMBINATION RATE OF RISE
PLUS FIXED TEMPERATURE
SMOKE DETECTORP
(SMOKE DETECTOR CONTROL FUNCTION)
P- SMOKE REFRACTION, PHOTOELECTRIC
A- SMOKE ALARM WITH AUDIBLE SOUNDER
BASE
E- ELEVATOR CONTROLS
BEAM TRANSMITTERBT
BEAM RECEIVERBR
PE DUCT SMOKE DETECTOR (PHOTOELECTRIC)
SPEAKER- WALL MOUNTED
SPEAKER- CEILING MOUNTED
STROBE- WALL MOUNTED
CANDELA RATING
(STROBE SHALL BE 15cd U.O.N.)
STROBE- CEILING MOUNTED
CANDELA RATING
(STROBE SHALL BE 15cd U.O.N.)
SPEAKER/STROBE- WALL MOUNTED
CANDELA RATING
(STROBE SHALL BE 15cd U.O.N.)
(XX)
SPEAKER/STROBE- CEILING MOUNTED
(XX) CANDELA RATING
(STROBE SHALL BE 15cd U.O.N.)
FIREFIGHTER PHONE JACK
DOOR HOLDER
SURGE SUPPRESSOR
FLOW DETECTOR/SWITCH
PRESSURE DETECTOR/SWITCH
TAMPER DETECTOR/SWITCH
VALVE WITH TAMPER DETECTOR/SWITCH
DOOR HARDWARE IDENTIFICATION
(XX)
(XX)
TYPE No.
DETAIL No.
MASS NOTIFICATION TRANSMITTER PANELTRX
MASS NOTIFICATION CONTROL PANEL
MASS NOTIFICATION STROBE POWER EXTENDER PANEL
MASS NOTIFICATION SPEAKER- WALL MOUNTED
MASS NOTIFICATION SPEAKER- CEILING MOUNTED
MASS NOTIFICATION STROBE- WALL MOUNTED
CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)
MASS NOTIFICATION STROBE- CEILING MOUNTED
CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)
MASS NOTIFICATION SPEAKER/STROBE- WALL MOUNTED
CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)(XX)
MASS NOTIFICATION SPEAKER/STROBE- CEILING MOUNTED
(XX) CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)
LOCAL OPERATOR CONSOLE
TRANSMITTER ANTENNA
(XX)
(XX)
MNS
SPE
M
M
M
M
M
M
M
COMBINATION FIRE ALARM AND MNS SPEAKER WITH
SEPARATE CLEAR FIRE ALARM STROBE AND AMBER
MNS STROBE - WALL MOUNTED
CANDELA RATING 15cd U.O.N. (ACCOUNT FOR
DE-RATING THROUGH AMBER LENS)
(XX)
FA/MNS
(XX)
FA/MNS CANDELA RATING 15cd U.O.N. (ACCOUNT FOR
DE-RATING THROUGH AMBER LENS)
COMBINATION FIRE ALARM AND MNS SPEAKER WITH
SEPARATE CLEAR FIRE ALARM STROBE AND AMBER
MNS STROBE - CEILING MOUNTED
A ---------------------
A OR AMP AMPERE
ACU AUTONOMOUS CONTROL UNIT
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINIHSED GRADE
AHU AIR HANDLING UNIT
ANN ANNUNCIATOR
ARCH ARCHITECT
ARA AREA OF RESCUE ASSISTANCE
B ---------------------
BKR BREAKER
BFP BACK FLOW PREVENTER
C ---------------------
C OR CDT CONDUIT
C/B CIRCUIT BREAKER
CBL CABLE
CKT CIRCUIT
CL CENTERLINE
CLG CEILING
CO CLEANOUT
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONTR CONTRACTOR
D ---------------------
DEMO DEMOLITION
DIA DIAMETER
DISC DISCONNECT
DIST DISTANCE
DW DOMESTIC WATER
DWG DRAWING
DP DISTRIBUTION PANEL
DSP DRY STANDPIPE
E ---------------------
(E) EXISTING
EC ELECTRICAL CONTRACTOR
ELEC ELECTRICAL
ELEV ELEVATOR
EO ELECTRICALLY OPERATED
EQUIP EQUIPMENT
EX EXISTING
F ---------------------
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
F.B.O. FURNISHED BY OWNER
FD FLOOR DRAIN
FDV FIRE DEPARTMENT VALVE
FDVC FIRE DEPARTMENT VALVE CABINET
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FHR FIRE HOSE RACK
FL. FLOOR
FP FIRE PUMP
FS FLOW SWITCH
FTR FIRE ALARM TRANSPONDER PANEL
FUT FUTURE
G ---------------------
GA GAUGE
GC GENERAL CONTRACTOR
GPM GALLON PER MINUTE
H ---------------------
HP HORSEPOWER
HT HEIGHT
HVAC HEATING, VENTILATING, AIR CONDITIONING
I ---------------------
ID INSIDE DIMENSION
J ---------------------
JB JUNCTION BOX
JUNC JUNCTION
K ---------------------
KW KILOWATT
L ---------------------
LOC LOCAL OPERATING CONSOLE
LT LIGHT
LV LOW VOLTAGE
M ---------------------
MAX MAXIMUM
MCB MAIN CIRCUIT BREAKER
MFR MANUFACTURER
MIN MINIMUM
MNS MASS NOTIFICATION SYSTEM
MTD MOUNTED
N ---------------------
(N) NEW
NAC NOTIFICATION APPLIANCE CIRCUIT
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
O ---------------------
OD OUTSIDE DIAMETER
P ---------------------
PC PLUMBING CONTRACTOR
PIV POST INDICATOR VALVE
PNL PANEL
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PWR POWER
R ---------------------
RE REMOVE EXISTING
RAP REMOTE ANNUNCIATOR PANEL
REQ REQUIRED
GENERAL ABBREVIATIONS
S ---------------------
SIAM SIAMESE
SLC SIGNALING LINE CIRCUIT
SLV SLEEVE
SP STANDPIPE
SPEC SPECIFICATION
SPR SPRINKLER
ST SHUNT TRIP
SPEP STROBE POWER EXTENDER PANEL
STD STANDARD
SW SWITCH
SYS. SYSTEM
T ---------------------
TEL TELEPHONE
TEMP TEMPERATURE
TYP TYPICAL
U ---------------------
U.L. UNDERWRITER'S LABORATORY
U.O.N. UNLESS OTHERWISE NOTED
V ---------------------
V VOLT
VCC VOICE COMMAND CENTER
W ---------------------
W WIRE
WP WEATHERPROOF
WSP WET STANDPIPE
X ---------------------
XDR TRANSDUCER
XMTR TRANSMITTER
XPDR TRANSPONDER
SYMBOLS ---------------------
* DISTANCE DOWN FROM CEILING
+ DISTANCE ABOVE FINISHED FLOOR
FIRE ALARM AND MASS NOTIFICATION SYMBOLS
COMBINATION DEVICE SYMBOLS
MASS NOTIFICATION SYMBOLS
FINISHED CEILING
REMOTE ANNUNCIATOR
5'
MAX
FMCU
6'
MAX
EXIT DOOR
5' MAX
48"
CENTER
FINISHED
FLOOR
MIN.
90"
MIN.
80"
16"
6" MIN.
NOTES: 1. IN MANSONRY CONSTRUCTION THE ABOVE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO NEAREST BLOCK OR
BRICK COURSING.
2. THE ABOVE MOUNTING HEIGHTS SHALL BE ADHERED TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE DRAWINGS OR SPECIFICATIONS. SEE G.3 AND INTERIOR ELEVATIONS FOR SPECIFIC MOUNTING HEIGHTS.
3. DO NOT INSTALL ANY EQUIPMENT OUTSIDE UNLESS IT IS LISTED FOR OUTDOOR USE.
4. FOR LOW CEILINGS WHERE THE MOUNTING HEIGHTS CAN NOT BE MET, MOUNT THE INDICATING APPLIANCE (EX: SPEAKERS, STROBE) 6" FROM THE CEILING.
5. MOUNT ALL INDICATING APPLIANCES ON THE WALL, UNLESS INDICATED OTHERWISE.
6. ALL DEVICE & APPLIANCE HEIGHTS SHOULD BE CONSISTENT FOR THE ENTIRE PROJECT. THE FIRE PANEL SHALL HAVE A MINIMUM 3 FT CLEARANCE FROM THE FRONT OF THE CONTROL EQUIPMENT & BE LOCATED IN A CLIMATE CONTROLLED AREA.
AC
C
EP
TA
BL
E
M O
U N
TI
N
G A
R
EA
F O
R
AU
D
IB
LE
A
PP
LI
AN
C
E.
D
IS
TA
N C
E S
AR
E
M
EA
SU
R
ED
F
R O
M T
H E
TO
P
O F
TH
E
AP
PL
IA
N
C E.
AC
C
EP
TA
BL
E
M O
U N
TI
N
G A
R
EA
F O
R
ST
R
O
BE
S , O
R A
U D
IB
LE
/S
TR
O B
E C
O M
BI
N
AT
IO
N A
PP
LI
AN
C
ES
(N
O N
S
LE
EP
IN
G R
O O
M S
AN
D
C O
R R
ID
O
R S)
. D
IS
TA
N
C E
S
AR
E M
EA
SU
R
ED
S O
T H
AT
T
H E
E N
TI
R
E
LE
N S
M U
ST
B
E W
IT
H
IN
T
H E
AR
EA
S H
O W
N
ANN
F
GENERAL NOTES
SPEAKER- WALL MOUNTED
SPEAKER- CEILING MOUNTED
CLEAR FIRE ALARM/ MNS STROBE- WALL MOUNTED
CANDELA RATING 15cd U.O.N.
FA/MNS
FA/MNS
FA/MNS
FA FIRE ALARM SYSTEM
MNS MASS NOTIFICATION SYSTEM
A ADMINISTRATIVE MASS NOTIFICATION SYSTEM
CLEAR FIRE ALARM/ MNS STROBE- CEILING MOUNTED
CANDELA RATING 15cd U.O.N.(XX)
FA/MNS
(XX)
STANDARD MOUNTING HEIGHTS
AREA OF REFUGE TWO WAY OF COMMUNICATION CALL BOX
AREA OF REFUGE TWO WAY COMMUNICATION CONTROL
STATION
I A
ARA
MASS NOTIFICATION TRANSMITTER PANELTRX
AIR SAMPLING SMOKE DETECTOR PANELASSD
POWER SOURCEVPS
KNOX BOXKB
UNINTERRUPTED POWER SUPPLYUPS
AIR SAMPLING SMOKE DETECTOR PORT
LOCAL OPERATING CONSOLELOC
LOC
M
AX
(T O
H
IG
H E
ST
B
U
TT
O N
) ACCEPTABLE
MOUNTING AREA
FOR MANUAL PULL
STATION MEASURED
FROM THE CENTER
OF THE HANDLE
DEMO PLANS - EXISTING CONDITIONS DESIGNATIONS:
EX EXISTING TO REMAIN
RE REMOVE EXISTING
ME MODIFY EXISTING
REX RELOCATE EXISTING
NEW WORK PLANS - EXISTING CONDITIONS DESIGNATIONS:
EX EXISTING TO REMAIN
ME MODIFY EXISTING
ER EXISTING RELOCATED
EXISTING DESIGNATIONS
NAC NOTIFICATION APPLIANCE POWER SUPPLY
LOC
FMCU
CONTROL MODULECM
1. KEYED NOTES ARE INDICATED ON PLANS BY SYMBOL
2. REFER TO HVAC MECHANICAL DRAWINGS FOR EXACT LOCATION OF DUCT SMOKE DETECTORS IN AIR HANDLING UNIT.
3. REFER TO SPRINKLER DRAWINGS FOR EXACT LOCATION AND QUANTITY OF SUPERVISED VALVES AND FLOW SWITCHES.
4. SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 72-2019, UFC-3-600-01, AND UFC 4-021-01.
5. LOCATE SMOKE DETECTORS MINIMUM 36 INCHES FROM HVAC DIFFUSERS.
6. LOCATE VISUAL DEVICES A MINIMUM OF 80" ABOVE FINISHED FLOOR OR 6" BELOW THE FINISHED CEILING, WHICHEVER IS LOWER. THE
MAXIMUM MOUNTING HEIGHT IS 96" ABOVE FINISHED FLOOR.
7. VISUAL DEVICE CANDELA RATING SHALL BE AS INDICATED ON DRAWING.
8. INSTALL ALL WIRING IN CONDUIT. CONDUIT MUST BE MINIMUM 3/4-INCH.
9. ALL DEVICES ARE TO BE PROTECTED DURING CONSTRUCTION.
10. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED DEVICES/APPLIANCES.
11. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE
RECORD DRAWINGS.
12. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. ALL CHANGES
SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS.
13. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION.
14. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT.
15. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER.
16. ANY SMOKE DETECTOR HEAD INSTALUED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST.
ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER.
17. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT
WORK IS NOT ACTIVELY BEING PERFORMED.
18. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC.
19. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC).
20. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN
ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE.
21. FIRE ALARM CABLE INSTALLED IN DUCTS. PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP.
22. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN
SHAFTS SHALL BE TYPE FPLR.
23. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS.
24. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70
ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE.
25. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS.
26. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT.
27. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING.
28. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS.
29. DEMOLISH ALL EXISTING FIRE ALARM AND MASS NOTIFICATION EQUIPMENT AS SHOWN ON DEMOLITION PLANS. ADDITIONALLY, REMOVE THE EXISTING FIRE ALARM RADIO ALARM TRANSCEIVER ANTENNA FROM THE ROOF OF THE BUILDING. PACKAGE ALL FIRE ALARM SYSTEM CONTROL
EQUIPMENT AND TURN OVER TO THE CONTRACTING OFFICER FOR SPARE PART STOCK.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
FA001
SHERM
FI
R
E
AL
AR
M
G
EN
ER
AL
N O
TE
S
W
ES
T
PO
IN
T, N Y
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
E R
AL
P
LA
ZA
, N
EW
Y O
R K, N Y
JC
M
D
PF
JA
B
J
U
LY
W
2D S1
7D
RTA SUBMISSION
C
BU
P S
H
ER
M
AN
B
AR
R
AC
K S
W
2D S1
8F
PN
IS
SU
ED
B Y
AM
EN
D M
EN
T
/0
9/
BREAK GLASS SENSOR
PASSIVE INFRARED/MICROWAVE SENSOR
360° PASSIVE INFRARED/MICROWAVE SENSOR
REQUEST TO EXIT PUSH BUTTON
REQUEST TO EXIT PASSIVE INFRARED SENSOR
ACCESS CONTROL & INTRUSION DETECTION
CARD READER
DOOR STRIKE
ELECTROMAGNETIC LOCKING DEVICE
CCTV CAMERA, FIXED
SEISMIC SENSOR
CARD READER WITH KEYPAD
BALANCED MAGNETIC SWITCH
DURESS PANIC SWITCH
AREA NOTIFICATION EQUIPMENT
SECURITY PANEL
POWER SUPPLY
CELL BOOSTER ENCLOSURE
SECURITY ENCLOSURE
SIREN
VIDEO INTERCOM (MASTER)
MISCELLANEOUS SYSTEMS
TELEPHONE AND DATA COMMUNICATIONS
TELEPHONE TERMINAL BOARD (TB)
TELEPHONE TERMINAL CABINET (TC)
TELEPHONE WALL OUTLET
DATA WALL OUTLET
AV = AUDIO VISUAL
M = MODULAR OR SYSTEM FURNITURE
TV = TELEVISION
DATA OUTLET IN COMMON FLOOR BOX WITH ELECTRICAL OUTLET
COMBINATION TELEPHONE AND DATA WALL OUTLET
COMBINATION TELEPHONE AND DATA OUTLET IN COMMON FLOOR
BOX WITH ELECTRICAL OUTLET
EQUIPMENT RACK
MICROPHONE OUTLET CEILING
PUBLIC ADDRESS PUSHBUTTON
VOLUME CONTROL AND CHANNEL SELECTOR
CEILING MOUNTED SPEAKER
WALL MOUNTED SPEAKER
BUZZER SWITCH
TELEVISION OUTLET
TELEPHONE CEILING OUTLET
ELECTRIFIED LOCK SET
CCTV MONITORPRIMARY BONDING BUSBAR (PBB); SECONDARY BONDING BUSBAR (SBB)
BUILDING ENTRANCE TERMINAL
CCTV CAMERA, PAN-TILT-ZOOM
WIRELESS ACCESS POINT (WAP) CEILING OUTLET
COMBINATION TELEPHONE AND DATA CEILING OUTLET
CHIME
AMPLIFIER
BASKET CABLE TRAY
CONSOLIDATION POINT
TWO POST RELAY RACK
M
TELEPHONE OUTLET IN COMMON FLOOR BOX WITH ELECTRICAL OUTLET
SIPRNET WALL OUTLETS
POKE-THRU
WALL MOUNTED JUNCTION BOX WITH FLEXIBLE WHIP TO FURNITURE BASE
POWER FEED, MOUNT AT 18-INCHES ABOVE FINISHED FLOOR
FLOOR BOX FEED WITH FLEXIBLE WHIP TO FURNITURE BASE POWER FEED
POWER POLE FEED WITH FLEXIBLE WHIP TO FURNITURE BASE POWER FEED
LADDER CABLE TRAY
T
T
TP
BET
CP
SINGLE FACE DIGITAL CLOCK, 2 = DOUBLE FACE
PROGRAM BELL
PROGRAM BUZZER
MIC
PA
V
C
TV
AMP
CH
KEYPAD
ML
EL
DS
AUDIO SENSOR DEVICE
P
INTERCOM:
M = MASTER STATION
R = REMOTE STATION
VIDEO INTERCOM (REMOTE)
CELLULAR TRANSMITTER
SP
CBE
ENC
BADGING WORKSTATIONBWS
ALARM MONITORING WORKSTATIONAWS
ACCESS CONTROL SYSTEM PANELACS
INTRUSION DETECTION SYSTEM PANELIDS
SITE
EXISTING MANHOLE (CMH) OR EXISTING HANDHOLE (CHH)
NEW MANHOLE (CMH) OR NEW HANDHOLE (CHH)
COMMUNICATIONS DUCTBANK
EXISTING COMMUNICATIONS DUCTBANK
C
Cx
TELECOMMUNICATIONS SYMBOLS
110 BLOCKS110
MIC
MIC
MICROPHONE OUTLET FLOOR
MICROPHONE OUTLET WALL
C
ACEG ALTERNATING CURRENT EQUIPMENT GROUND
ACS ACCESS CONTROL SYSTEM
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
ANN ANNUNCIATOR
ARCH ARCHITECTURAL
AV AUDIO AND VISUAL
BAS BUILDING AUTOMATION SYSTEM
BATT BATTERY
B BACKBONE
BBC BACKBONE BONDING CONDUCTOR
BBV BACKBONE VOICE
BEPB BUILDING ENTRANCE PROTECTION BLOCKS
BFPP BACKBONE FIBER PATCH PANEL
BLDG BUILDING
BMS BALANCED MAGNETIC SWITCH
BVPP BACKBONE VOICE PATCH PANEL
C CONDUIT
CAB CABINET
CAT CATEGORY
CCTV CLOSED CIRCUIT TELEVISION
CFCI CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CLG CEILING
CMH COMMUNICATIONS MANHOLE
COB CENTER OF BOX
COMM COMMUNICATIONS
CONST CONSTRUCTION
CONT CONTINUATION
DIST DISTRIBUTION
DWG DRAWING
EF ENTRANCE FACILITY
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EQPT EQUIPMENT
EXIST EXISTING
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FIXT FIXTURE
FLR FLOOR
FO FIBER OPTIC
GFGI GOVERNMENT FURNISHED GOVERNMENT
INSTALLED
HCPP HORIZONTAL COPPER PATCH PANEL
HFPP HORIZONTAL FIBER PATCH PANEL
HOV HORIZONTAL VOICE
HVPP HORIZONTAL VOICE PATCH PANEL
HWPP HORIZONTAL WIRELESS PATCH PANEL
IDS INTRUSION DETECTION SYSTEM
ISP INDOOR CABLE PLANT
JB JUNCTION BOX
MFR MANUFACTURER
MH MOUNTING HEIGHT
MMF MULTI MODE FIBER
MTD MOUNTED
NC NURSE CALL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OH OVERHEAD
OSP OUTDOOR CABLE PLANT
PA PUBLIC ADDRESS
PB PULL BOX
PBB PRIMARY BONDING BUSBAR
PBX PRIVATE BRANCH EXCHANGE
PC PERSONAL COMPUTER
PLAS PLASTIC
PP PATCH PANEL
PR PAIR
PWR POWER
QTY QUANTITY
RBB RACK BONDING BUSBAR
RBC RACK BONDING CONDUCTOR
RECP RECEPTACLE
REQD REQUIRED
RGS RIGID GALVANIZED STEEL
RM ROOM
RSC RIGID STEEL CONDUIT
RU RACK UNIT
SBB SECONDARY BONDING BUSBAR
SCRT SECURITY
SECT SECTION
SPEC SPECIFICATION
SMF SINGLE MODE FIBER
SP SERVICE PROVIDER
SURF SURFACE
SW SWITCH
SYM SYMMETRICAL
SYS SYSTEMS
TBB TELECOMMUNICATIONS BONDING BACKBONE
TBC TELECOMMUNICATIONS BONDING CONDUCTOR
TEBC TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR
TEL TELEPHONE
TELCOM TELECOMMUNICATIONS
TER TELECOMMUNICATIONS EQUIPMENT ROOM
TR TELECOMMUNICATIONS ROOM
TYP TYPICAL
UG UNDERGROUND
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
WP WEATHERPROOF
XFR TRANSFER
XP EXPLOSION PROOF
DATA OUTLETS
NC OUTLETS
TELEPHONE OUTLETS
TELEPHONE AND DATA OUTLETS
COUNTER TOP OUTLETS (CT)
WIRELESS ACCESS POINT
HORN SPEAKERS
TELEVISION OUTLET (TV)
CARD READER BACK BOX
SPEAKER VOLUME CONTROL
18-INCHES
48-INCHES
48-INCHES
18-INCHES
8 INCHES ABOVE COUNTER
AT FINISHED CEILING
AS INDICATED
60-INCHES
40-INCHES
40-INCHES
1. ALL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES SHOWN ARE NOT
NECESSARILY USED ON THIS PROJECT.
2. REFER TO ONE-LINE DIAGRAMS FOR CABLE SIZES, CONDUIT SIZES, AND DEVICES NOT
SHOWN ON PLANS.
3. MOUNTING HEIGHTS FOR CEILING MOUNTED DEVICES ARE TO THE BOTTOM OF THE
DEVICE, UNLESS OTHERWISE NOTED.
4. MOUNTING HEIGHTS ABOVE FINISHED FLOOR, TO CENTERLINE OF DEVICE, ARE AS
FOLLOWS, UNLESS OTHERWISE NOTED:
5. ALL EXPOSED CABLES IN THE TELECOM EQUIPMENT ROOM (TER) AND TELECOM ROOMS
(TR) MUST BE INSTALLED INSIDE POLYETHYLENE TEREPHTHALATE (PET) EXPANDABLE
BRAIDED SLEEVING TO PROVIDE A PROFESSIONAL LOOK ON FINISHED PRODUCT.
PROVIDE YELLOW COLORED SLEEVING FOR DATA CABLING AND GREEN COLORED
SLEEVING FOR VOICE CABLES.
6. CONTRACTOR MUST SUPPLY FACTORY TERMINATED FIBER OPTIC AND CAT 6 PATCH
CORDS FOR EACH DATA PORTS AND CAT 6A FOR WIRELESS PORTS AT THE TELECOM
EQUIPMENT ROOM (TER) AND TELECOM ROOMS (TR) ON EACH FLOOR FOR A COMPLETE
AND WORKING TURN-KEY COMMUNICATIONS SYSTEM. LENGTH OF PATCH CORDS TO BE
DETERMINED BY USMA/NEC PROJECT MANAGER. PATCH CORDS MUST BE COLOR-
CODED TO MATCH WITH HORIZONTAL CABLE COLORS. CONTRACTOR MUST ALSO
SUPPLY 200 EACH 5 FEET, AND 200 EACH 7 FEET GREEN JACKET CAT 6 PATCH CORDS
FOR THE OUTSIDE PLANT (OSP) COPPER CABLE CROSS CONNECTION IN THE TELECOM
ROOMS.
7. THE FOLLOWING COLOR CODED MUST BE USED FOR HORIZONTAL WIRING:
• GREEN (JACKET, JACKS PATCH CORDS) FOR VOICE
• BLUE (JACKET, JACKS, PATCH CORDS) FOR WREN DATA
• YELLOW (JACKET, JACKS, PATCH CORDS) FOR NIPR DATA
• ORANGE (JACKET, JACKS, PATCH CORDS) FOR WREN WIRELESS
• WHITE (JACKET, JACKS, PATCH CORDS) FOR CCTV CAMERAS
• GRAY (JACKET, JACKS, PATCH CORDS) FOR CHC DATA
• LT BLUE (JACKET, JACKS, PATCH CORDS) FOR CHC WIRELESS
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
T-001
LEE
T E
L E
C O
M M
U N
IC
A
T
IO
N S
S Y
M B
O L S
A
B B
R E
V
IA
T
IO
N S
A N
D G
E N
E R
A L N
O T
E S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
S L H
C A
T
J D
H
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
TELECOMMUNICATIONS ABBREVIATIONS TELECOMMUNICATIONS GENERAL NOTES
IS
S U
E D
B Y
A M
E N
D M
E N
T
/1 /2
C
C P
C
C
O
M
M
C
O
M
M
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
COMM
C O
M M
C O
M M
C O
M M
C O
M M
C O
M
M
C O
M
M
C O
M
M
C O
M
M
C O
M M
C O
M M
C O
M M
CO
M
M
C O
M M
COMM
COMM
COMM
COMM
COMM
COMM
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C
C
CYBER & ENGINEERING ACADEMIC CENTER
X X X X X X X X
X
X
X
X
X
X
X
X X
X
C O
M M
COMM C
C
C
O
M
M
C
O
M
M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C O
M M
C O
M M
C O
M M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
COMM
COMM
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C O
M M
C O
M M
C
O
M
M
C O
M M
C O
M M
C O
M M
COMM
COMM
C O
M M
VAULT
MH 22
MH 3
MH X6
MH X5
MH X4
MH 2C
MH 2A
MH 2
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
COMM COMM COMM COMM
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C
O
M
M
C
O
M
M
COMM
COMM
COMM
COMM
COMM
C
O
M
M
MH 3E
C
O
M
M
C
O
M
M
C
O
M
M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
MH X3
MH 3B
MH 3A1
MH 3A
C
C
C
C
C
C
C
C
C
C
C
C
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
MH35B
EXISTING
MH34B
MH34
C
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
TER
MH35C
EXISTING
COMM COMM COMM
COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM
TAYLOR HALL
(EX) CABLE VAULT
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
CEAC
1 C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
I S
S U
D
B
Y
A
M E
N D
M E
N T
C A
T
S L H
O V
E R
A L L
S
I T
E
P
L A
N
L E
E
B
A R
R A
C K
S
T E
L E
C
TS100
30' 60'0
N
A1
TELECOM OVERALL SITE PLAN - LEE BARRACKS
SCALE: 1"=30'
KEY NOTES
1 NEW FIBER OPTIC CABLES IN EXISTING
DUCTBANK/MANHOLE SYSTEM. REFERENCE
ONE-LINE DIAGRAM T-600 FOR CABLE
REQUIREMENTS. COORDINATE WITH EXISTING
CONDITIONS AND BASE COMM FOR EXACT
ROUTING OF NEW CABLE.
D A
T E
M A
R K
D E
S C
R I P
T I O
N
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
SHEET ID
W D
S F
U S
A
R M
Y
C
O R
F
E
N G
I N
E E
R S
US Army Corps of Engineers
N E
W
Y
O R
K
D
I S
T R
I C
T
F
E D
E R
A L
P
L A
Z A
N
W
R
K
N
Y
W D
S D
J U
L
A N
S I
D
W E
I N
T
N
Y
C B
U
L
E
B
A R
R A
C K
RTA SUBMISSION
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
LEE
A1
TS101
W/D W/DW/DW/DW/D
CC
C x1 x2 x3 x4 x5 x6 x7 x8 x9 x10 x11 x12 x13 x14 xL xK xJ xH xG
ELEV.
LE-2-1
STAIR 1
LS-2-1
STAIR 2
LS-2-2
CADET ROOM
L2015
LAUNDRY
L203
COLLABORATION
ROOM
L205
CADET ROOM
L2001
CORRIDOR
L200
CADET ROOM
L2002
CADET ROOM
L2003
CADET ROOM
L2004
CADET ROOM
L2005
CADET ROOM
L2006
TAC
L2007
TAC
L2008
TAC
L2009
CADET ROOM
L2010
CADET ROOM
(ABA)
L2011
CADET ROOM
L2012
CADET ROOM
L2013
CADET ROOM
L2014
MEN'S ROOM
L208
ELEC.
L201
WOMEN'S
ROOM
L202
TELECOM
L206
JANITOR
L204
18"W X 2"H CABLE TRAY
MOUNTED AT 7'-4" AFF
T-401
B8
ECS
DAS
ECS
DAS2
TV
AV
T-401
C8
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PLAN NORTH
T-102
LEE
S E
C O
N D
F L O
O R
C O
M M
U N
IC
A
T
IO
N S
P L A
N
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
S L H
C A
T
J D
H
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"C1
SECOND FLOOR - COMMUNICATIONS
PLAN
MOUNT AT 48 INCHES ABOVE FINISHED FLOOR FOR LAUNDRY PAYMENT
SYSTEM. COORDINATE LOCATION OF UNIT.
ALL OUTLETS AT DESKS IN CADET ROOMS ARE MOUNTED AT 40-INCHES
ABOVE FINISHED FLOOR.
KEY NOTES
IS
S U
E D
B Y
A M
E N
D M
E N
T
/1 /2
W/DW/D
CC
C x1 x2 x3 x4 x5 x6 x7 x8 x9 x10 x11 x12 x13 x14 xL xK xJ xH xG
CADET ROOM
L3015
COLLABORATION
ROOM
L305a
CADET ROOM
L3001
CORRIDOR
L300
CADET ROOM
L3002
CADET ROOM
L3003
CADET ROOM
L3004
CADET ROOM
L3005
CADET ROOM
L3006
CADET ROOM
L3007
CADET ROOM
L3008
CADET ROOM
L3010
CADET ROOM
L3011
CADET ROOM
L3012
CADET ROOM
L3013
CADET ROOM
L3014
CADET ROOM
L3016
STAIR 2
LS-3-2
ELEV.
LE-3-1
STAIR 1
LS-3-1
WOMEN'S
ROOM
L302
ELEC.
L301
STORAGE
L304
18"W X 2"H CABLE TRAY
MOUNTED AT 7'-4" AFF
CCQ
L3009
TELECOM
L306
MEN'S ROOM
L308
JANITOR
L307
COLLABORATION
STORAGE
ROOM
L305b
LAUNDRY
L303
ECS
DAS
ECS
DAS2 2
TV
AV
T-402
A1
T-402
D1
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PLAN NORTH
T-103
LEE
T H
IR
D
F L O
O R
C O
M M
U N
IC
A
T
IO
N S
P L A
N
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
S L H
C A
T
J D
H
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"C1
THIRD FLOOR - COMMUNICATIONS PLAN
KEY NOTES
IS
S U
E D
B Y
A M
E N
D M
E N
T
/1 /2
MOUNT AT 48 INCHES ABOVE FINISHED FLOOR FOR LAUNDRY PAYMENT
SYSTEM. COORDINATE LOCATION OF UNIT.
ALL OUTLETS AT DESKS IN CADET ROOMS ARE MOUNTED AT 40-INCHES
ABOVE FINISHED FLOOR.
BLANK
COVER #8B
1-1/4 INCH HOUSING
ASSEMBLY AND SIX
PORT OPENING PLATE
FOR COMMUNICATION
CABLES AND JACKS
1-1/4 INCH HOUSING ASSEMBLY AND
1-9/16 INCH RECEPTACLE OPENING
PLATE FOR AUDIO VISUAL CABLES
20A DUPLEX RECEPTACLE
(TYP OF 2) SEE ELECTRICAL
NOTE: COVERS NOT SHOWN FOR CLARITY
AV
CHC
DATA CAT 6 GRAY
CABLE AND JACKS
COMBINATION DATA AND ELECTRICAL
SYSTEM FURNITURE POKE-THRU
M
CHC/NC
2-INCH GROMMET
FOR GFGI CABLING
VOICE CAT 6 GREEN
CABLE AND CAT 6
GREEN JACK
8-INCH POKE-THRU
SEE ELECTRICAL
3-PORT PLASTIC
FACE PLATE
DATA 1 BLANK DATA 2
M
3 PORT MODULAR FURNITURE DATA OUTLET
DATA CAT 6 CABLE
AND JACK, BLUE
DATA CAT 6 CABLE
AND JACK, BLUE
AV OUTLET
TV
1 1/4-INCH CONDUIT
STUBBED ABOVE CEILING
AV OUTLET
AV
2-INCH CONDUIT STUBBED
ABOVE CEILING
1 1/4-INCH
GROMMET 2-INCH
GROMMET
4 11/16" SQUARE x 2 1/8" DEEP
BACKBOX WITH SINGLE GANG
PLASTER RING AND HIGH IMPACT
PLASTIC GROMMET FACEPLATE
4 11/16" SQUARE x 3 1/4" DEEP
BACKBOX WITH DOUBLE GANG
PLASTER RING AND HIGH IMPACT
PLASTIC GROMMET FACEPLATE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
T-502
LEE
D E
T A
IL
S
F
L O
O R
O U
T L E
T S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
S L H
C A
T
J D
H
J
U L Y
W D
S D
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
1. TERMINATE ALL COPPER CABLES ON JACKS WITH T568A PIN-OUT.
NOT TO SCALEA1
AUDIO VISUAL POKE-THRU DEVICES
NOT TO SCALED1
MODULAR FURNITURE OUTLET
GENERAL NOTES
NOT TO SCALEC4
TV AND AV OUTLETS
IS
S U
E D
B Y
A M
E N
D M
E N
T
/1 /2
(EX) MH-3CMH-X4
S
M F
O S
P
S
M F
O S
P
F O
C B
-1
DUCTBANK
12 SMF OSP(FOC B600, 1-12)
(EX) MH-2 (EX) MH-2A
EXISTING DUCTBANK
48 SMF ISP/OSP 48 SMF ISP/OSP
(EX) MH-22
EXISTING DUCTBANK
B2 TELECOM RM 29C
TAYLOR HALL (B600)
BFPP
EXISTING RACK
BFPP
EXISTING RACK
48 SMF ISP/OSP
EXISTING DUCTBANK
REFERENCE SHEET T-601
FOR CONTINUATION
CABLE VAULT
200 PR OSP (CA17, 801-1000)
CMH-X5
(EX) MH-35B
(EX) MH-35C
EXISTING DUCTBANK
S
M F
O S
P
144 SMF OSP 144 SMF OSP
EXISTING DUCTBANK EXISTING DUCTBANK
EXISTING TER
BFPP
EXISTING RACK
E X
IS
T
IN
G
D U
C T
B A
N K
12 MMF 62.5 OSP (FOC CB1, 133-144)
24 MMF 62.5 OSP (BIT)
24 SMF OSP (FOC 600D1, 73-96)
48 SMF OSP
B2 DAS RM
D U
C T
B A
N K
S
M F
O S
P
SPLICE EXISTING
FIBER AND
COPPER CABLES
48 SMF OSP
72 SMF OSP
(E X
)4 P
R O
S P
C
A -1
(E X
M
M F
.5
O S
P F
O C
C B
-1
P U
L L I N
F R
O M
C M
H -X
M
M F
.5
O S
P
B
IT
S
M F
O S
P
F O
C
D
-9
12 SMF OSP (FOC B600, 1-12)
D U
C T
B A
N K
S
M F
I S
P /O
S P
TO SHERMAN BARRACKS
DUCTBANK
24 SMF OSP (FOC 600D1, 73-96)
EXISTING SPLICE
S
M F
O S
P
F O
C B
-1
12 SMF OSP(FOC B600, 1-12) 12 SMF OSP(FOC B600, 1-12) 12 SMF OSP(FOC B600, 1-12)
(EX) 2' X 3' X 2'
GS HANDHOLE
SPLICE
(EX) 12 PR COPPER CABLE (GS)
(EX) 12 SMF CABLE (GS)
(EX) BET)
(EX) FPP
(EX) GUARD SHACK (GS)
12 PR BET
1U FPP
(EX) B606
(EX) MH 34
(WALL MTD)
(EX. RACK MTD)
(EX) TER
PROVIDE PATCH CORDS TO RESTORE LAN, VOICE AND CCTV
CONNECTIONS AT GS. COORDINATE WITH GVERNMENT.
PROVIDE PATCH CORDS TO RESTORE LAN, VOICE AND CCTV
CONNECTIONS AT GS. COORDINATE WITH GVERNMENT.
12 PR COPPER CABLE (GS)
12 SMF CABLE (GS)
DISCONNECT AND REMOVE CABLES FROM B606 AND
CONNECT CABLES TO LEE PRIOR TO B606 DEMOLITION
S
M F
A N
D
P
R C
O P
P E
R C
A B
L E
G
S
P
R C
O P
P E
R C
A B
L E
G
S
S
M F
C A
B L E
G
S
12 SMF AND 12 PR COPPER CABLE (GS)
144 SMF OSP
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y