Amendment 0008_Combined Drawings Final 9-10-21.pdf

PDF 11 MB Posted

Attached to
Building 740, Lee Barracks and Building 738, Sherman Barracks Repair
Solicitation number
W912DS21B0004
Issued by

About this file

This document provides details on a federal contract opportunity for repair work at two barracks buildings on an Army base. The U.S. Army Corps of Engineers, New York District will issue a solicitation for a firm-fixed price contract to repair Building 740 at Lee Barracks and Building 738 at Sherman Barracks, including interior renovations, mechanical and electrical system replacements, and site work. Renovations at Building 740 will support 192 cadets, while repairs at the optional Building 738 work will support 321 cadets. The solicitation is expected to post on August 6, 2021 with proposals due approximately 30 days later. The period of performance is estimated at 1,034 calendar days. The estimated value of the contract is between $100-200 million. Vendors must register with the System for Award Management to receive the solicitation.

View the file

Other files

File Type Posted
Bid Abstract.pdf PDF
W912DS21B0004 Amendment 11.pdf PDF
Lee Barracks Electrical Drawings for Amendment.pdf PDF
Amendment 0010.pdf PDF
Amendment 0009.pdf PDF
Amendment 0008_Combined Specifications 9-10-21.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007_LEE-SHERMAN SPECS rev.pdf PDF
Amendment 0007_Lee Sherman Section 01 32 00 Scheduling.pdf PDF
Amendment 0007_Dwgs_Sherman Barracks.pdf PDF
Amendment 0007_Building 740 Lee Barracks Site Walk through Sign in Sheet.pdf PDF
Amendment 0007.pdf PDF
Amendment 0007_Dwgs_Lee Barracks.pdf PDF
Amendment 0007_Sherman Barracks GER.pdf PDF
Amendment 0007_5.4 GER_West Point Lee Barracks signed.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0004_STEAM VAULT AMENDMENT DRAWINGS SHERMAN.pdf PDF
Amendment 0004_STEAM VAULT AMENDMENT DRAWINGS LEE.pdf PDF
Amendment 0004_Photos_Steam Vault F-4.pdf PDF
Amendment 0004_Photos_Steam Vault F-8.pdf PDF
Amendment 0004_WP Lee and Sherman Steam Vault Amendment SPECIFICATIONS 17 AUG 2021.pdf PDF
Amendment 0004_Photos_Steam Vault F-3.pdf PDF
Amendment 0003_RTA Drawings Lee Vol 1_Part3.pdf PDF
Amendment 0003_RTA Drawings Lee Vol 1_Part1.pdf PDF
Amendment 0003_RTA Drawings Lee Vol 1_Part2.pdf PDF
Amendment 0003_RTA Drawings Lee Vol 1_Part4.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
RTA Drawings Lee Vol 2.pdf PDF
RTA Drawings Lee Vol 3.pdf PDF
RTA Drawings Lee Vol 1_Part3.pdf PDF
RTA Drawings Lee Vol 1_Part2.pdf PDF
RTA Drawings Lee Vol 1_Part1.pdf PDF
RTA Drawings Sherman Vol 2_Part2.pdf PDF
RTA Drawings Sherman Vol 2_Part1.pdf PDF
RTA Drawings Sherman Vol 1_Part2.pdf PDF
RTA Drawings Sherman Vol 1_Part1.pdf PDF
VOL 3 WP Lee and Sherman RTA Specs 23 JULY 2021.pdf PDF
VOL 2 WP Lee and Sherman RTA Specs 23 JULY 2021.pdf PDF
W912DS-21-B-0004_Solicitation.pdf PDF
VOL 4 WP Lee and Sherman RTA Specs 23 JULY 2021.pdf PDF
VOL 1 WP Lee and Sherman RTA Specs 23 JULY 2021.pdf PDF
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRE ALARM CONTROL PANELFACP

FIRE ALARM ANNUNCIATOR

STROBE POWER EXTENDER

FIRE ALARM TRANSPONDER

MANUAL PULL STATION

ANN

SPE

FTR

F

INTERFACE MODULEIM

HEAT DETECTORR

(HEAT DETECTOR CONTROL FUNCTION)

R - THERMAL, RATE OF RISE

F - THERMAL, FIXED TEMPERATURE

FR - THERMAL, COMBINATION RATE OF RISE PLUS

FIXED TEMPERATURE

SMOKE DETECTORP

(SMOKE DETECTOR CONTROL FUNCTION)

S - AREA SMOKE, IONIZATION

P - SMOKE REFRACTION, PHOTOELECTRIC

D - DUCT MOUNTED, SMOKE IONIZATION

M - MULTI CRITERIA (LIGHT OBSCURATION AND

THERMAL)

A - AUDIBLE BASE

P DUCT SMOKE DETECTOR (PHOTOELECTRIC)

SPEAKER- WALL MOUNTED

SPEAKER- CEILING MOUNTED

STROBE- WALL MOUNTED

CANDELA RATING

(STROBE SHALL BE 15cd U.O.N.)

STROBE- CEILING MOUNTED

CANDELA RATING

(STROBE SHALL BE 15cd U.O.N.)

SPEAKER/STROBE- WALL MOUNTED

CANDELA RATING

(STROBE SHALL BE 15cd U.O.N.)

(XX)

SPEAKER/STROBE- CEILING MOUNTED

(XX) CANDELA RATING

(STROBE SHALL BE 15cd U.O.N.)

FIREFIGHTER PHONE JACK

DOOR HOLDER

SURGE SUPPRESSOR

FLOW DETECTOR/SWITCH

PRESSURE DETECTOR/SWITCH

TAMPER DETECTOR/SWITCH

VALVE WITH TAMPER DETECTOR/SWITCH

(XX)

(XX)

MASS NOTIFICATION TRANSMITTER PANEL TRX

MASS NOTIFICATION CONTROL PANEL

MASS NOTIFICATION STROBE POWER EXTENDER PANEL

MASS NOTIFICATION SPEAKER- WALL MOUNTED

MASS NOTIFICATION SPEAKER- CEILING MOUNTED

MASS NOTIFICATION STROBE- WALL MOUNTED

CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)

MASS NOTIFICATION STROBE- CEILING MOUNTED

CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)

MASS NOTIFICATION SPEAKER/STROBE- WALL MOUNTED

CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)(XX)

MASS NOTIFICATION SPEAKER/STROBE- CEILING MOUNTED

(XX) CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)

TRANSMITTER ANTENNA

(XX)

(XX)

MNS

SPE

M

M

M

M

M

M

M

COMBINATION FIRE ALARM AND MNS SPEAKER WITH

SEPARATE CLEAR FIRE ALARM STROBE AND AMBER MNS

STROBE - WALL MOUNTED

CANDELA RATING 15cd U.O.N. (ACCOUNT FOR DE-RATING

THROUGH AMBER LENS)

(XX)

(XX)

CANDELA RATING 15cd U.O.N. (ACCOUNT FOR DE-RATING

THROUGH AMBER LENS)

F/M

F/M

COMBINATION FIRE ALARM AND MNS SPEAKER WITH

SEPARATE CLEAR FIRE ALARM STROBE AND AMBER MNS

STROBE - CEILING MOUNTED

A ---------------------

A OR AMP AMPERE

ACU AUTONOMOUS CONTROL UNIT

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINIHSED GRADE

AHU AIR HANDLING UNIT

ANN ANNUNCIATOR

ARCH ARCHITECT

ARA AREA OF RESCUE ASSISTANCE

B ---------------------

BKR BREAKER

BFP BACK FLOW PREVENTER

C ---------------------

C OR CDT CONDUIT

C/B CIRCUIT BREAKER

CBL CABLE

CKT CIRCUIT

CL CENTERLINE

CLG CEILING

CO CLEANOUT

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONTR CONTRACTOR

D ---------------------

DEMO DEMOLITION

DIA DIAMETER

DISC DISCONNECT

DIST DISTANCE

DW DOMESTIC WATER

DWG DRAWING

DP DISTRIBUTION PANEL

DSP DRY STANDPIPE

E ---------------------

(E) EXISTING

EC ELECTRICAL CONTRACTOR

ELEC ELECTRICAL

ELEV ELEVATOR

EO ELECTRICALLY OPERATED

EQUIP EQUIPMENT

EX EXISTING

F ---------------------

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

F.B.O. FURNISHED BY OWNER

FD FLOOR DRAIN

FDV FIRE DEPARTMENT VALVE

FDVC FIRE DEPARTMENT VALVE CABINET

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FHR FIRE HOSE RACK

FL. FLOOR

FP FIRE PUMP

FS FLOW SWITCH

FTR FIRE ALARM TRANSPONDER PANEL

FUT FUTURE

G ---------------------

GA GAUGE

GC GENERAL CONTRACTOR

GPM GALLON PER MINUTE

H ---------------------

HP HORSEPOWER

HT HEIGHT

HVAC HEATING, VENTILATING, AIR CONDITIONING

I ---------------------

ID INSIDE DIMENSION

J ---------------------

JB JUNCTION BOX

JUNC JUNCTION

K ---------------------

KW KILOWATT

L ---------------------

LOC LOCAL OPERATING CONSOLE

LT LIGHT

LV LOW VOLTAGE

M ---------------------

MAX MAXIMUM

MCB MAIN CIRCUIT BREAKER

MFR MANUFACTURER

MIN MINIMUM

MNS MASS NOTIFICATION SYSTEM

MTD MOUNTED

N ---------------------

(N) NEW

NAC NOTIFICATION APPLIANCE CIRCUIT

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NTS NOT TO SCALE

O ---------------------

OD OUTSIDE DIAMETER

P ---------------------

PC PLUMBING CONTRACTOR

PIV POST INDICATOR VALVE

PNL PANEL

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PWR POWER

R ---------------------

RE REMOVE EXISTING

RAP REMOTE ANNUNCIATOR PANEL

REQ REQUIRED

GENERAL ABBREVIATIONS

S ---------------------

SIAM SIAMESE

SLC SIGNALING LINE CIRCUIT

SLV SLEEVE

SP STANDPIPE

SPEC SPECIFICATION

SPR SPRINKLER

ST SHUNT TRIP

SPEP STROBE POWER EXTENDER PANEL

STD STANDARD

SW SWITCH

SYS. SYSTEM

T ---------------------

TEL TELEPHONE

TEMP TEMPERATURE

TYP TYPICAL

U ---------------------

U.L. UNDERWRITER'S LABORATORY

U.O.N. UNLESS OTHERWISE NOTED

V ---------------------

V VOLT

VCC VOICE COMMAND CENTER

W ---------------------

W WIRE

WP WEATHERPROOF

WSP WET STANDPIPE

X ---------------------

XDR TRANSDUCER

XMTR TRANSMITTER

XPDR TRANSPONDER

SYMBOLS ---------------------

* DISTANCE DOWN FROM CEILING

+ DISTANCE ABOVE FINISHED FLOOR

FIRE ALARM SYMBOLS

COMBINATION DEVICE SYMBOLS

MASS NOTIFICATION SYMBOLS

BUILDING CONSTRUCTION CODE DATA FINISHED CEILING

REMOTE ANNUNCIATOR

5'

MAX

FACP

6'

MAX

EXIT DOOR

5' MAX

48"

CENTER

FINISHED

FLOOR

MIN.

90"

MIN.

80"

16"

6" MIN.

NOTES: 1. IN MASONRY CONSTRUCTION THE ABOVE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO NEAREST BLOCK OR

BRICK COURSING.

2. THE ABOVE MOUNTING HEIGHTS SHALL BE ADHERED TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE

DRAWINGS OR SPECIFICATIONS.

3. DO NOT INSTALL ANY EQUIPMENT OUTSIDE UNLESS IT IS LISTED FOR OUTDOOR USE.

4. FOR LOW CEILINGS WHERE THE MOUNTING HEIGHTS CAN NOT BE MET, MOUNT THE INDICATING APPLIANCE (EX: SPEAKERS, STROBE) 6" FROM THE CEILING.

5. MOUNT ALL INDICATING APPLIANCES ON THE WALL, UNLESS INDICATED OTHERWISE.

6. ALL DEVICE & APPLIANCE HEIGHTS SHOULD BE CONSISTENT FOR THE ENTIRE PROJECT. THE FIRE PANEL SHALL HAVE A MINIMUM 3 FT CLEARANCE FROM THE FRONT OF THE CONTROL EQUIPMENT & BE LOCATED IN A CLIMATE CONTROLLED AREA.

A C

C E

P T

A B

L E

M O

U N

T

IN

G A

R E

A F

O R

A U

D

IB

L E

A P

P L

IA

N C

E D

IS

T

A N

C E

S A

R E

M E

A S

U R

E D

F R

O M

T H

E T

O P

O F

T H

E A

P P

L

IA

N C

E

A C

C E

P T

A B

L E

M O

U N

T

IN

G A

R E

A F

O R

S

T R

O B

E S

O

R A

U D

IB

L E

/S T

R O

B E

C O

M B

IN

A

T

IO

N A

P P

L

IA

N C

E S

(N

O N

S L E

E P

IN

G

R O

O M

S A

N D

C

R

R

ID

O R

S

D

IS

T A

N C

E S

A R

M

A S

U R

E D

S O

T H

A T

T H

E E

N T

IR

E

L E

U S

T B

E W

IT

H

IN

T

H E

A R

E A

S H

O W

N

ANN

F

GENERAL NOTES

SPEAKER- WALL MOUNTED

SPEAKER- CEILING MOUNTED

CLEAR FIRE ALARM/ MNS STROBE- WALL MOUNTED

CANDELA RATING 15cd U.O.N.

F/M

F/M

F/M

F FIRE ALARM SYSTEM

M MASS NOTIFICATION SYSTEM

CLEAR FIRE ALARM/ MNS STROBE- CEILING MOUNTED

CANDELA RATING 15cd U.O.N.(XX)

F/M

(XX)

STANDARD MOUNTING HEIGHTS

AREA OF REFUGE TWO WAY OF COMMUNICATION CALL BOX

AREA OF REFUGE TWO WAY COMMUNICATION CONTROL

STATION

I A

ARA

MASS NOTIFICATION TRANSMITTER PANEL TRX

AIR SAMPLING SMOKE DETECTOR PANELASSD

POWER SOURCEVPS

KNOX BOXKB

UNINTERRUPTED POWER SUPPLYUPS

AIR SAMPLING SMOKE DETECTOR PORT

LOCAL OPERATING CONSOLELOC

LOC

M A

X

T

H

IG

H

E S

T B

U T

T O

N

ACCEPTABLE

MOUNTING AREA

FOR MANUAL PULL

STATION MEASURED

FROM THE CENTER

OF THE HANDLE

DEMO PLANS - EXISTING CONDITIONS DESIGNATIONS:

EX EXISTING TO REMAIN

RE REMOVE EXISTING

ME MODIFY EXISTING

REX RELOCATE EXISTING

NEW WORK PLANS - EXISTING CONDITIONS DESIGNATIONS:

EX EXISTING TO REMAIN

ME MODIFY EXISTING

ER EXISTING RELOCATED

EXISTING DESIGNATIONS

BUILDING CODE: INTERNATIONAL BUILDING CODE, 2018

FIRE CODE: NFPA 1, FIRE CODE, 2018

SITE LOCATION: WEST POINT, NY

FIRE ALARM SYSTEM: ADDRESSABLE MANUAL VOICE EVACUATION FIRE ALARM/

MASS NOTIFICATION SYSTEM. AUTOMATIC DETECTION.

PROPOSED WORK SHALL COMPLY WITH:

NFPA 70, NATIONAL ELECTRICAL CODE, 2020

NFPA 72, NATIONAL FIRE ALARM CODE, 2019

NFPA 101, LIFE SAFETY CODE, 2018

ICC/ANSI A117.1—10 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES

UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, 8 OCTOBER 2019

UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, CHANGE

4, 7 FEBRUARY 2020

UFC 4-101-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS,

12 DECEMBER 2018

UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, CHANGE

1, JANUARY 2010

USACE ECB 2018-17 NEW REQUIREMENTS FOR VISUAL

NOTIFICATION FOR MASS NOTIFICATION SYSTEMS, 14 MAY 2020, REV 1

UFC 4-510-01, DESIGN: MILITARY MEDICAL FACILITIES

FACP/

ACU

FIRE ALARM CONTROL PANEL/ AUTONOMOUS CONTROL UNIT

CARBON MONOXIDE DETECTOR

FIRE ALARM AMPLIFIERAMP

1. DRAWING NOTES ARE INDICATED ON PLANS BY SYMBOL

2. REFER TO HVAC MECHANICAL DRAWINGS FOR EXACT LOCATION OF DUCT SMOKE DETECTORS IN AIR HANDLING UNIT.

3. REFER TO SPRINKLER DRAWINGS FOR EXACT LOCATION AND QUANTITY OF SUPERVISED VALVES AND FLOW SWITCHES.

4. SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES INCLUDING NFPA 72-2019, UFC-3-600-01, AND UFC 4-021-01.

5. LOCATE SMOKE DETECTORS MINIMUM 36 INCHES FROM HVAC DIFFUSERS.

6. LOCATE VISUAL DEVICES A MINIMUM OF 80" ABOVE FINISHED FLOOR OR 6" BELOW THE FINISHED CEILING, WHICHEVER IS LOWER. THE MAXIMUM

MOUNTING HEIGHT IS 96" ABOVE FINISHED FLOOR.

7. VISUAL DEVICE CANDELA RATING SHALL BE AS INDICATED ON DRAWING.

8. INSTALL ALL WIRING IN MINIMUM 3/4" CONDUIT.

9. ALL DEVICES ARE TO BE PROTECTED DURING CONSTRUCTION.

10. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED DEVICES/APPLIANCES.

11. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE

RECORD DRAWINGS.

12. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE

WORK SHOWN.

13. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. ALL CHANGES SHALL

BE CLEARLY INDICATED ON THE RECORD DRAWINGS.

14. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION.

15. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT.

16. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER.

17. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED TECHNICAL REPRESENTATIVE.

18. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST.

ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER.

19. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT

WORK IS NOT ACTIVELY BEING PERFORMED.

20. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC.

21. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC).

22. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN

ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE.

23. FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUMS, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP.

24. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN

SHAFTS SHALL BE TYPE FPLR.

25. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS.

26. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 ARTICLES

760, 770, 725 AND 800 WHERE APPLICABLE.

27. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS.

28. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT.

29. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING.

30. MAINTAIN 40 PERCENT MAXIMUM CONDUIT FILL RATIO AS PER NEC REQUIREMENTS.

31. DEMOLISH ALL EXISTING FIRE ALARM AND MASS NOTIFICATION EQUIPMENT AS SHOWN ON DEMOLITION PLANS. ADDITIONALLY, REMOVE THE EXISTING FIRE ALARM RADIO ALARM TRANSCEIVER ANTENNA FROM THE ROOF OF THE BUILDING. PACKAGE ALL FIRE ALARM SYSTEM CONTROL

EQUIPMENT AND TURN OVER TO THE CONTRACTING OFFICER FOR SPARE PART STOCK.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

FA001

LEE

F

IR

E A

L A

R M

G E

N E

R A

L N

O T

E S

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

T A

W

P C

K

C N

M

J

U L Y

W D

S D

RTA SUBMISSION

C B

U P

L E

E B

A R

R A

C K

S

W D

S F

P N

IS

S U

E D

B Y

A M

E N

D M

E N

T

/2

/2

IS

S U

E D

B Y

A M

E N

D M

E N

T

/0

/2

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

PP

P

P

P

PP

P

P

P

P P

P P

P P P P P

P

P

P P P

P

PPP

P P P P P P

P

P

P

P

PP

P

P P

P

S P

E

S P

E

P

IM

IM

IM

IM

P

IM

P

FF

15 15

IM

IM IM IMIM

IM IM IMIM

PF

P

IM

P

IM

IM

IM

R

W P

1 2 3 4 5 6 7 8 109 11 12 13 14

G

G'

J

K

L

FIRE PUMP ROOM

LB001

STAIR 2

LS-B-2

ELEV. 1

LE-B-1

STAIR 1

LS-B-1

ELECTRICAL

LC004

TEAM ROOM 1 - WKTM1

LC040

STAFF TOILET - TLTU1

LC002

SCREENING / TRIAGE

ROOM EXRG4

LC030

LABORATORY - LBPC1

LC015b

BLOOD DRAW - LBVP1

LC015a

PATIENT TOILET -

TLTU1

LC007

SCREENING / TRIAGE

ROOM EXRG4

LC032

SPECIALTY ROOM

EXRG1

LC034

EXAM ROOM EXRG1

LC036

EXAM ROOM EXRG1

LC038

STAFF LOUNGE - SL001

LC018

STAFF TOILET - TLTU1

LC020

OBSERVATION /

HYDRATION - OOHR1

LC028b

ELEVATOR 2

LE-B-2

WAITING ANCILLARY

SERVICES

LC01c

MECHANICAL

L001a

EXAM ROOM EXRG1

LC039

EXAM ROOM EXRG1

LC037

EXAM ROOM EXRG1

LC035

EXAM ROOM EXRG1

LC033

EXAM ROOM EXRG1

LC031

WAITING ROOM

LC01d

CIRCULATION

LC03

CIRCULATION

LC02

ISOLATION EXRG6

LC011a

CHC STAIR 4

LS-B-4

TEAM ROOM 2 - WKTM1

LC005

TOILET TLTU1

LC011b

HEIGHT / WEIGHT

LC010

CONSULT

(BH/NUTRITION) OFDC2

LC008

AED - RCA01

LC016

SPECIMEN TOILET -

TLTU1

LC017 RECEPTION

LC012a

APPOINTMENT CLERK

LC012b

TREATMENT/IMMUNIZATION

- TRGM1/OPIR1

LC029

NURSE STATION -

NSTA1

LC028a

OFFICE NCOIC / CNOC -

OFA05

LC023

OFFICE OIC/CHIEF -

OFA04

LC024

OFFICE CARE

COORDINATOR - OFA04

LC021

CADET SURGEON -

OFA04

LC022

OFFICE CARE

COORDINATOR- OFA04

LC025

CONFERENCE ROOM -

CRA01

LC026

EVS JANC1

LC027

OFFICE TBI RESEARCH

ANALYST - OFA05

LC019 TOILET TLTU1

LC014

COPY SUPPLY RPR01

LC12c

SOILED LINEN - USCL1

LC009

TEAM ROOM 3-4 -

WKTM1

LC001

EQUIPMENT STORAGE -

SRE01

LC003

CLEAN - UCCL1

LC006

A M

P

A M

P

M

ELEVATOR MACHINE

ROOM

L001b

X5

04 8 16268

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

FA100B

LEE

B A

S E

M E

N T

F

IR

E A

L A

R M

P L A

N

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

T A

W

P C

K

C N

M

J

U L Y

W D

S D

RTA SUBMISSION

C B

U P

L E

E B

A R

R A

C K

S

W D

S F

P N

DRAWING NOTES

1 COORDINATE QUANTITY & LOCATION OF DUCT DETECTORS WITH MECHANICAL CONTRACTOR

(TYP). DUCT DETECTORS ASSOCIATED WITH FIRE/SMOKE DAMPERS TO BE PROVIDED WITH

REMOTE TEST STATIONS. IF POSSIBLE COLLOCATE REMOTE TEST STATIONS. COORDINATE

LOCATION AND QUANTITY OF REMOTE TEST STATIONS WITH MECHANICAL CONTRACTOR (TYP.).

2 PROVIDE 4 ADDRESSABLE INTERFACE MODULES FOR FIRE PUMP SUPERVISION. PROVIDE IN

ACCORDANCE WITH NFPA72 & NFPA20.

3 PROVIDE SMOKE DETECTOR TO INITIATE ELEVATOR RECALL. MACHINE ROOM DETECTOR AND

ELEVATOR LOBBY DETECTORS TO INITIATE ELEVATOR RECALL, AND SHALL CAUSE THE FIRE

FIGHTER'S SERVICE VISUAL SIGNAL TO FLASH IN ANY ELEVATOR CAB THAT SERVES THE

AFFECTED LOBBY.

4 PROVIDE SPE PANEL AND AMP PANELS AS REQUIRED FOR FIRE ALARM AND MASS NOTIFICATION

SYSTEM.

5 PROVIDE 5 ADDRESSABLE INTERFACE MODULES FOR ELEVATOR FUNCTIONS. PROVIDE IN

ACCORDANCE WITH NFPA72 & NFPA20.

6 PROVIDE MONITORING FOR FLOW SWITCH AND SUPERVISED TAMPER SWITCH SERVING

ELEVATOR MACHINE ROOM SPRINKLER(S). FLOW SWITCH SHALL SHUNT POWER TO ELEVATORS

SERVED BY MACHINE ROOM AND HAVE NO TIME DELAY. COORDINATE WITH FIRE SPRINKLER

WORK.

7 SUPERVISED TAMPER SWITCH FOR SPRINKLER SYSTEM CONTROL VALVE.

8 SUPERVISED FLOW SWITCH FOR FLOOR ZONE CONTROL ASSEMBLY.

1/8" = 1'-0"1

BASEMENT FIRE ALARM PLAN

IS

S U

E D

B Y

A M

E N

D M

E N

T

/2

/2

IS

S U

E D

B Y

A M

E N

D M

E N

T

/0

/2

SPE

P

15 15

P

P P

P

P

P

P

P

P P

P P

P

P

P

P

P

P P

P

P

P

P

P P

PP

PP

P

PP

P

P P

P P

P P

P

F

P

PP

FACP

P

P

P

P

IM

F

F

F

30 30

IM

IM

SPE

P

IM

IM

IM

IM

IM

P

WP

WP

WP

1 2 3 4 5 6 7 8 109 11 12 13 14

G

G'

J

K

L

TOILET

LCS11

TOILET

LCS10

EYE LANE - EYEL1

LCS08

HEARING BOOTH -

PEHS2

LCS05

WAITING ROOM -

WRC01

LCS04

PLUMBING

LS01b

TELECOM

LS05

PLUMBING CLEAN OUT

ROOM

LB001c

STORAGE

LS07

VESTIBULE - LOB02

LS09

CIRCULATION

LCS001

STAIR 2

LS-S-2

ELEVATOR 1

LE-S-1

STAIR 1

LS-S-1

BEAUTY STORAGE

LB010

BEAUTY SHOP

LB003

LAUNDRY

LB009 AIR/VAC

LB001d

JANITOR CLOSET

LS06

BARBER SHOP

LB001a

CHC STAIR 4

LS-S-4

ELEVATOR 2

LE-S-2

OFFICE

LB004

CLINIC PHARMACY -

PHOD1

LCS01

EXIT PASSAGE

LCS002CIRCULATION

LCS003

MECHANICAL

LS03

BARBER STORAGE

LB001e

ELECTRICAL

LS02

EYE VISION SCREENING

DISPENSING - EYVS1

LCS07

STORAGE

LCS09

RECEPTION

LCS02

WHEELCHAIR ALCOVE

LCS06

KIOSK - CLSC1

LCS04b

AED - RCA01

LCS03

STAFF LOUNGE

LB005

CHECK-IN KIOSKS

LB002

STAFF SUPPORT

LB01

MIXING

LB008

VENDING AREA

LS04

VESTIBULE

LS10

STORAGE

LB001b

APRON & COAT HOOKS

LB001f

ROOF ACCESS STAIR 3

LS-S-3

TRX

FACP/

ACU

M

AMP

AMP

WOMEN'S ROOM

LB006

11 9

04 8 16268

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

FA100S

LEE

S U

B B

A S

E M

E N

T F

IR

E

A L A

R M

P L A

N

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

T A

W

P C

K

C N

M

J

U L Y

W D

S D

RTA SUBMISSION

C B

U P

L E

E B

A R

R A

C K

S

W D

S F

P N

1/8" = 1'-0"1

SUB BASEMENT FIRE ALARM PLAN

DRAWING NOTES

1 ADDRESSABLE CONTROL MODULE FOR ACTIVATION OF SMOKE DAMPER. SMOKE DAMPER MUST CLOSE UPON ACTIVATION OF ANY SPOT TYPE SMOKE DETECTOR LOCATED WITHIN A SPACE SERVED BY THE ASSOCIATED DUCT WORK. REFER TO MECHANICAL DRAWINGS FOR DUCT WORK AND AIR DIFFUSER LOCATIONS. PROVIDE A REMOTE INDICATOR LIGHT VISIBLE FROM FLOOR LEVEL TO INDICATE WHEN THE CONTROL MODULE IS ACTIVATED AND THE DAMPER IS CLOSED.

2 PROVIDE SMOKE DETECTOR TO INITIATE ELEVATOR RECALL. MACHINE ROOM DETECTOR AND ELEVATOR LOBBY DETECTORS TO INITIATE ELEVATOR RECALL, AND SHALL CAUSE THE FIRE FIGHTER'S SERVICE VISUAL SIGNAL TO FLASH IN ANY ELEVATOR

CAB THAT SERVES THE AFFECTED LOBBY.

3 PROVIDE SPE PANEL AND AMP PANELS AS REQUIRED FOR FIRE ALARM AND MASS NOTIFICATION SYSTEM.

4 FIRE ALARM CONTROL PANEL WITH REMOTE MIC.

5 PROVIDE MONITORING FOR FLOW SWITCH AND SUPERVISED TAMPER SWITCH SERVING ELEVATOR MACHINE ROOM SPRINKLER(S). FLOW SWITCH SHALL SHUNT POWER TO ELEVATORS SERVED BY MACHINE ROOM AND HAVE NO TIME DELAY.

COORDINATE WITH FIRE SPRINKLER WORK.

6 TYPICAL LOC SHALL HAVE A REMOTE MICROPHONE THAT EMULATES THE OPERATING OF THE ACU, INDIVIDUAL PUSHBUTTONS ACTIVATING THE MNS PRERECORDED MESSAGES, AND MANUAL ACTIVATION OF AHU SHUTDOWN. PROVIDE TAMPER

PROTECTION. ENCLOSURES THAT CAN BE ONLY BE OPENED BY A KEY SHALL NOT BE USED.

7 PROVIDE A CONTROL MODULE TO OVERRIDE PUBLIC ADDRESS SYSTEM WHEN A FIRE ALARM OR MASS NOTIFICATION SYSTEM

MESSAGE IS ACTIVE.

8 CIRCUIT FROM THE CENTRAL GUARD ROOM (CGR) LOCATED IN EISENHOWER HALL SHALL BE ROUTED THROUGH THIS ROOM THROUGH THE TELECOMMUNICATIONS DUCTBANK. ROUT CIRCUIT TO THE FIRE ALARM / MASS NOTIFICATION CONTROL PANEL AND CONNECT TO THE TELEPHONE PORT. THIS CONNECTION IS PROVIDED TO RECEIVE ANNOUNCEMENTS FROM THE CGR

WHICH WILL BE TRANSMITTED OVER THE MNS SPEAKER SYSTEM.

9 SUPERVISED TAMPER SWITCH FOR STANDPIPE RISER CONTROL VALVE.

10 SUPERVISED FLOW SWITCH FOR FLOOR ZONE CONTROL ASSEMBLY.

11 SUPERVISED TAMPER SWITCH FOR SPRINKLER SYSTEM CONTROL VALVE.

IS

S U

E D

B Y

A M

E N

D M

E N

T

/2

/2

IS

S U

E D

B Y

A M

E N

D M

E N

T

/0

/2

P P

P

P

P

P

P P P P P

P

P

P P P P P P

P

P

P

1515 15

30 30 30

FF

A N

N

IM

IM

IM

P

IM

IM

IM

R

IM

IM

IM

IM

IM

IM

IM

IM

S P

E

S P

E

W P

W P

WP

1 2 3 4 5 6 7 8 109 11 12 13 14

G

G'

J

K

L

STAIR 2

LS-1-2

ELEV.

LE-1-1

STAIR 1

LS-1-1

ELEC.

L102

VESTIBULE

L103

VESTIBULE

L108 STORAGE

L107

MAIN TELECOM - CHC

L110A

TRUNK ROOM

L114

MAIN TELECOM -

CADET

L110B

EQUIPMENT CLEANING

AREA

L109

JANITORS BREAK

ROOM

L101a

CORRIDOR

L100

TRUNK ROOM

L111

WOMEN'S ROOM

L106

MEN'S ROOM

L105

STORAGE

L104

TAC SUPPORT

L113

JANITOR'S OFFICE

L101b

M

X5

ELEVATOR MACHINE

ROOM

L112

A M

P

A M

P

2 2

04 8 16268

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

FA101

LEE

F

IR

S T

F L O

O R

F

IR

E A

L A

R M

P L A

N

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

T A

W

P C

K

C N

M

J

U L Y

W D

S D

RTA SUBMISSION

C B

U P

L E

E B

A R

R A

C K

S

W D

S F

P N

DRAWING NOTES

1 PROVIDE SMOKE DETECTOR TO INITIATE ELEVATOR RECALL. MACHINE

ROOM DETECTOR AND ELEVATOR LOBBY DETECTORS TO INITIATE

ELEVATOR RECALL, AND SHALL CAUSE THE FIRE FIGHTER'S SERVICE

VISUAL SIGNAL TO FLASH IN ANY ELEVATOR CAB THAT SERVES THE

AFFECTED LOBBY.

2 ADDRESSABLE CONTROL MODULE FOR ACTIVATION OF SMOKE DAMPER.

SMOKE DAMPER MUST CLOSE UPON ACTIVATION OF ANY SPOT TYPE

SMOKE DETECTOR LOCATED WITHIN A SPACE SERVED BY THE

ASSOCIATED DUCT WORK. REFER TO MECHANICAL DRAWINGS FOR DUCT

WORK AND AIR DIFFUSER LOCATIONS. PROVIDE A REMOTE INDICATOR

LIGHT VISIBLE FROM FLOOR LEVEL TO INDICATE WHEN THE CONTROL

MODULE IS ACTIVATED AND THE DAMPER IS CLOSED.

3 PROVIDE SPE PANEL AND AMP PANELS AS REQUIRED FOR FIRE ALARM

AND MASS NOTIFICATION SYSTEM.

4 FIRE ALARM ANNUCIATOR PANEL W/ REMOTE MIC.

5 TYPICAL LOC SHALL HAVE A REMOTE MICROPHONE THAT EMULATES THE

OPERATING OF THE ACU, INDIVIDUAL PUSHBUTTONS ACTIVATING THE

MNS PRERECORDED MESSAGES, AND MANUAL ACTIVATION OF AHU

SHUTDOWN. PROVIDE TAMPER PROTECTION. ENCLOSURES THAT CAN BE

ONLY BE OPENED BY A KEY SHALL NOT BE USED.

6 PROVIDE 5 ADDRESSABLE INTERFACE MODULES FOR ELEVATOR

FUNCTIONS. PROVIDE IN ACCORDANCE WITH NFPA72 & NFPA20.

7 PROVIDE MONITORING FOR FLOW SWITCH AND SUPERVISED TAMPER

SWITCH SERVING ELEVATOR MACHINE ROOM SPRINKLER(S). FLOW

SWITCH SHALL SHUNT POWER TO ELEVATORS SERVED BY MACHINE

ROOM AND HAVE NO TIME DELAY. COORDINATE WITH FIRE SPRINKLER

WORK.

8 SUPERVISED TAMPER SWITCH FOR SPRINKLER SYSTEM CONTROL VALVE.

9 SUPERVISED FLOW SWITCH FOR FLOOR ZONE CONTROL ASSEMBLY.

1/8" = 1'-0"1

FIRST FLOOR FIRE ALARM PLAN

IS

S U

E D

B Y

A M

E N

D M

E N

T

/2

/2

IS

S U

E D

B Y

A M

E N

D M

E N

T

/0

/2

DRAIN TO OUTSIDE

GRADE

PACK ANNULAR SPACE WITH

WATERTIGHT SEALING SYSTEM,

CAULK BOTH SIDES

STORZ FIRE

DEPARTMENT

CONNECTION

EXTERIOR WALL (SEE

ARCHITECTURAL

DRAWINGS FOR

CONSTRUCTION)

TO SYSTEM

MAIN

COLLAR OR

FRICTION

CLAMP TO SECURE

RISER IN-PLACE

CHECK VALVE

AUTOMATIC

BALL DRIP

4 FT.

MIN. CEILING

ESCUTCHEON

18" TO 48"

(SEE ARCH.

DWGS FOR

EXACT HEIGHT)

DETAIL NOTES:

1. 24 INCHES MINIMUM IN ACCORDANCE WITH WATERFLOW DETECTION DEVICE MANUFACTURER

2. 6 TO 24 INCHES MINIMUM DEPENDING UPON WATERFLOW DETENTION DEVICE MANUFACTURER

3. PIPE AND VALVE CONNECTIONS SHOWN ARE DIAGRAMATIC. REFER TO SPECS FOR ALLOWABLE

CONNECTION TYPE.

FLOOR

SELF CONTAINED

TEST & DRAIN

ASSEMBLY

UNION

1 1/2"

STANDPIPE TEE

6" X 6" X 2 1/2"

2-1/2" X 4" NIPPLE

2-1/2" HOSE ANGLE VALVE

STANDPIPE RISER

DRAIN RISER

1 2

FLOOR CONTROL VALVE

SWING CHECK VALVE

PRESSURE GAUGE

WATER FLOW SWITCH

THREAD-O-LET

60"

7' - 6"

MIN.

NOTES:

1. WHEN ARM OVER IS MORE THEN 24"

INCHES IN LENGTH, THE ARM OVER

MUST BE SUPPORTED WITH A PIPE

HANGER.

2. CONNECT ALL ARM-OVERS TO THE

TOP THE BRANCH LINE PIPING.

BOTTOM OF DECK

NIPPLE AS

REQUIRED

BRANCH

SUPPLY LINE

CEILING

TEE 1" SUPPLY LINE

REDUCER AS REQUIRED

CONCEALED SPRINKLER

HEAD HOUSING

CONCEALED SPRINKLER

HEAD

SPRINKLER HEAD (SEE

SPRINKLER SCHEDULE

AND DRAWINGS FOR

TYPE)

SPRINKLER BRANCH

SIZE VARIES

1" PIPING TO NEW

CEILING ELEV. AND LOC.

1" x 1/2" REDUCER

BACKFLOW

PREVENTER

FLANGED OS&Y

VALVE WITH

TAMPER

SWITCH

1'-0" TO 4'-0"

ABOVE FLOOR

FLOOR

ADJUSTABLE PIPE SADDLE WITH

PIPE NIPPLE ATTACHED TO

STEEL BASE STAND, AND

CONCRETE PIER OR STEEL

SUPPORT

DIRECTION OF FLOW

INDICATING VALVE WITH

TAMPER SWITCH SIZED

AS SHOWN ON PLANS

MAIN DRAIN

UPSTREAM GUAGE

RISER CHECK VALVE

DOWNSTREAM GAUGE

FLOW SWITCH

TO SPRINKLER SYSTEM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F-701

LEE

F

IR

E P

R O

T E

C T

IO

N

D E

T A

IL

S

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

T A

W

P C

K

C N

M

J

U L Y

W D

S D

RTA SUBMISSION

C B

U P

L E

E B

A R

R A

C K

S

W D

S F

P N

NTS1

WALL MOUNTED STORZ FIRE

DEPARTMENT CONNECTION

NTS2

TYPICAL SPRINKLER FLOOR CONTROL

VALVE ASSEMBLY AND RISER

NTS3

CONCEALED SPRINKLER HEAD

NTS5

UPRIGHT SPRINKLER HEAD

NTS7

BACKFLOW PREVENTER

NTS8

RISER CHECK VALVE ASSEMBLY

IS

S U

E D

B Y

A M

E N

D M

E N

T

/2

/2

IS

S U

E D

B Y

A M

E N

D M

E N

T

/0

/2

FIRE ALARM AND MASS NOTIFICATION CONTROL PANEL

FIRE ALARM ANNUNCIATOR

STROBE POWER EXTENDER

FIRE ALARM TRANSPONDER

MANUAL PULL STATION

ANN

SPE

FTR

F

INTERFACE MODULEIM

HEAT DETECTORR

(HEAT DETECTOR CONTROL FUNCTION)

R- THERMAL, RATE OF RISE

F- THERMAL, FIXED TEMPERATURE

FR- THERMAL, COMBINATION RATE OF RISE

PLUS FIXED TEMPERATURE

SMOKE DETECTORP

(SMOKE DETECTOR CONTROL FUNCTION)

P- SMOKE REFRACTION, PHOTOELECTRIC

A- SMOKE ALARM WITH AUDIBLE SOUNDER

BASE

E- ELEVATOR CONTROLS

BEAM TRANSMITTERBT

BEAM RECEIVERBR

PE DUCT SMOKE DETECTOR (PHOTOELECTRIC)

SPEAKER- WALL MOUNTED

SPEAKER- CEILING MOUNTED

STROBE- WALL MOUNTED

CANDELA RATING

(STROBE SHALL BE 15cd U.O.N.)

STROBE- CEILING MOUNTED

CANDELA RATING

(STROBE SHALL BE 15cd U.O.N.)

SPEAKER/STROBE- WALL MOUNTED

CANDELA RATING

(STROBE SHALL BE 15cd U.O.N.)

(XX)

SPEAKER/STROBE- CEILING MOUNTED

(XX) CANDELA RATING

(STROBE SHALL BE 15cd U.O.N.)

FIREFIGHTER PHONE JACK

DOOR HOLDER

SURGE SUPPRESSOR

FLOW DETECTOR/SWITCH

PRESSURE DETECTOR/SWITCH

TAMPER DETECTOR/SWITCH

VALVE WITH TAMPER DETECTOR/SWITCH

DOOR HARDWARE IDENTIFICATION

(XX)

(XX)

TYPE No.

DETAIL No.

MASS NOTIFICATION TRANSMITTER PANELTRX

MASS NOTIFICATION CONTROL PANEL

MASS NOTIFICATION STROBE POWER EXTENDER PANEL

MASS NOTIFICATION SPEAKER- WALL MOUNTED

MASS NOTIFICATION SPEAKER- CEILING MOUNTED

MASS NOTIFICATION STROBE- WALL MOUNTED

CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)

MASS NOTIFICATION STROBE- CEILING MOUNTED

CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)

MASS NOTIFICATION SPEAKER/STROBE- WALL MOUNTED

CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)(XX)

MASS NOTIFICATION SPEAKER/STROBE- CEILING MOUNTED

(XX) CANDELA RATING (STROBE SHALL BE 15cd U.O.N.)

LOCAL OPERATOR CONSOLE

TRANSMITTER ANTENNA

(XX)

(XX)

MNS

SPE

M

M

M

M

M

M

M

COMBINATION FIRE ALARM AND MNS SPEAKER WITH

SEPARATE CLEAR FIRE ALARM STROBE AND AMBER

MNS STROBE - WALL MOUNTED

CANDELA RATING 15cd U.O.N. (ACCOUNT FOR

DE-RATING THROUGH AMBER LENS)

(XX)

FA/MNS

(XX)

FA/MNS CANDELA RATING 15cd U.O.N. (ACCOUNT FOR

DE-RATING THROUGH AMBER LENS)

COMBINATION FIRE ALARM AND MNS SPEAKER WITH

SEPARATE CLEAR FIRE ALARM STROBE AND AMBER

MNS STROBE - CEILING MOUNTED

A ---------------------

A OR AMP AMPERE

ACU AUTONOMOUS CONTROL UNIT

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINIHSED GRADE

AHU AIR HANDLING UNIT

ANN ANNUNCIATOR

ARCH ARCHITECT

ARA AREA OF RESCUE ASSISTANCE

B ---------------------

BKR BREAKER

BFP BACK FLOW PREVENTER

C ---------------------

C OR CDT CONDUIT

C/B CIRCUIT BREAKER

CBL CABLE

CKT CIRCUIT

CL CENTERLINE

CLG CEILING

CO CLEANOUT

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONTR CONTRACTOR

D ---------------------

DEMO DEMOLITION

DIA DIAMETER

DISC DISCONNECT

DIST DISTANCE

DW DOMESTIC WATER

DWG DRAWING

DP DISTRIBUTION PANEL

DSP DRY STANDPIPE

E ---------------------

(E) EXISTING

EC ELECTRICAL CONTRACTOR

ELEC ELECTRICAL

ELEV ELEVATOR

EO ELECTRICALLY OPERATED

EQUIP EQUIPMENT

EX EXISTING

F ---------------------

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

F.B.O. FURNISHED BY OWNER

FD FLOOR DRAIN

FDV FIRE DEPARTMENT VALVE

FDVC FIRE DEPARTMENT VALVE CABINET

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FHR FIRE HOSE RACK

FL. FLOOR

FP FIRE PUMP

FS FLOW SWITCH

FTR FIRE ALARM TRANSPONDER PANEL

FUT FUTURE

G ---------------------

GA GAUGE

GC GENERAL CONTRACTOR

GPM GALLON PER MINUTE

H ---------------------

HP HORSEPOWER

HT HEIGHT

HVAC HEATING, VENTILATING, AIR CONDITIONING

I ---------------------

ID INSIDE DIMENSION

J ---------------------

JB JUNCTION BOX

JUNC JUNCTION

K ---------------------

KW KILOWATT

L ---------------------

LOC LOCAL OPERATING CONSOLE

LT LIGHT

LV LOW VOLTAGE

M ---------------------

MAX MAXIMUM

MCB MAIN CIRCUIT BREAKER

MFR MANUFACTURER

MIN MINIMUM

MNS MASS NOTIFICATION SYSTEM

MTD MOUNTED

N ---------------------

(N) NEW

NAC NOTIFICATION APPLIANCE CIRCUIT

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NTS NOT TO SCALE

O ---------------------

OD OUTSIDE DIAMETER

P ---------------------

PC PLUMBING CONTRACTOR

PIV POST INDICATOR VALVE

PNL PANEL

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PWR POWER

R ---------------------

RE REMOVE EXISTING

RAP REMOTE ANNUNCIATOR PANEL

REQ REQUIRED

GENERAL ABBREVIATIONS

S ---------------------

SIAM SIAMESE

SLC SIGNALING LINE CIRCUIT

SLV SLEEVE

SP STANDPIPE

SPEC SPECIFICATION

SPR SPRINKLER

ST SHUNT TRIP

SPEP STROBE POWER EXTENDER PANEL

STD STANDARD

SW SWITCH

SYS. SYSTEM

T ---------------------

TEL TELEPHONE

TEMP TEMPERATURE

TYP TYPICAL

U ---------------------

U.L. UNDERWRITER'S LABORATORY

U.O.N. UNLESS OTHERWISE NOTED

V ---------------------

V VOLT

VCC VOICE COMMAND CENTER

W ---------------------

W WIRE

WP WEATHERPROOF

WSP WET STANDPIPE

X ---------------------

XDR TRANSDUCER

XMTR TRANSMITTER

XPDR TRANSPONDER

SYMBOLS ---------------------

* DISTANCE DOWN FROM CEILING

+ DISTANCE ABOVE FINISHED FLOOR

FIRE ALARM AND MASS NOTIFICATION SYMBOLS

COMBINATION DEVICE SYMBOLS

MASS NOTIFICATION SYMBOLS

FINISHED CEILING

REMOTE ANNUNCIATOR

5'

MAX

FMCU

6'

MAX

EXIT DOOR

5' MAX

48"

CENTER

FINISHED

FLOOR

MIN.

90"

MIN.

80"

16"

6" MIN.

NOTES: 1. IN MANSONRY CONSTRUCTION THE ABOVE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO NEAREST BLOCK OR

BRICK COURSING.

2. THE ABOVE MOUNTING HEIGHTS SHALL BE ADHERED TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE DRAWINGS OR SPECIFICATIONS. SEE G.3 AND INTERIOR ELEVATIONS FOR SPECIFIC MOUNTING HEIGHTS.

3. DO NOT INSTALL ANY EQUIPMENT OUTSIDE UNLESS IT IS LISTED FOR OUTDOOR USE.

4. FOR LOW CEILINGS WHERE THE MOUNTING HEIGHTS CAN NOT BE MET, MOUNT THE INDICATING APPLIANCE (EX: SPEAKERS, STROBE) 6" FROM THE CEILING.

5. MOUNT ALL INDICATING APPLIANCES ON THE WALL, UNLESS INDICATED OTHERWISE.

6. ALL DEVICE & APPLIANCE HEIGHTS SHOULD BE CONSISTENT FOR THE ENTIRE PROJECT. THE FIRE PANEL SHALL HAVE A MINIMUM 3 FT CLEARANCE FROM THE FRONT OF THE CONTROL EQUIPMENT & BE LOCATED IN A CLIMATE CONTROLLED AREA.

AC

C

EP

TA

BL

E

M O

U N

TI

N

G A

R

EA

F O

R

AU

D

IB

LE

A

PP

LI

AN

C

E.

D

IS

TA

N C

E S

AR

E

M

EA

SU

R

ED

F

R O

M T

H E

TO

P

O F

TH

E

AP

PL

IA

N

C E.

AC

C

EP

TA

BL

E

M O

U N

TI

N

G A

R

EA

F O

R

ST

R

O

BE

S , O

R A

U D

IB

LE

/S

TR

O B

E C

O M

BI

N

AT

IO

N A

PP

LI

AN

C

ES

(N

O N

S

LE

EP

IN

G R

O O

M S

AN

D

C O

R R

ID

O

R S)

. D

IS

TA

N

C E

S

AR

E M

EA

SU

R

ED

S O

T H

AT

T

H E

E N

TI

R

E

LE

N S

M U

ST

B

E W

IT

H

IN

T

H E

AR

EA

S H

O W

N

ANN

F

GENERAL NOTES

SPEAKER- WALL MOUNTED

SPEAKER- CEILING MOUNTED

CLEAR FIRE ALARM/ MNS STROBE- WALL MOUNTED

CANDELA RATING 15cd U.O.N.

FA/MNS

FA/MNS

FA/MNS

FA FIRE ALARM SYSTEM

MNS MASS NOTIFICATION SYSTEM

A ADMINISTRATIVE MASS NOTIFICATION SYSTEM

CLEAR FIRE ALARM/ MNS STROBE- CEILING MOUNTED

CANDELA RATING 15cd U.O.N.(XX)

FA/MNS

(XX)

STANDARD MOUNTING HEIGHTS

AREA OF REFUGE TWO WAY OF COMMUNICATION CALL BOX

AREA OF REFUGE TWO WAY COMMUNICATION CONTROL

STATION

I A

ARA

MASS NOTIFICATION TRANSMITTER PANELTRX

AIR SAMPLING SMOKE DETECTOR PANELASSD

POWER SOURCEVPS

KNOX BOXKB

UNINTERRUPTED POWER SUPPLYUPS

AIR SAMPLING SMOKE DETECTOR PORT

LOCAL OPERATING CONSOLELOC

LOC

M

AX

(T O

H

IG

H E

ST

B

U

TT

O N

) ACCEPTABLE

MOUNTING AREA

FOR MANUAL PULL

STATION MEASURED

FROM THE CENTER

OF THE HANDLE

DEMO PLANS - EXISTING CONDITIONS DESIGNATIONS:

EX EXISTING TO REMAIN

RE REMOVE EXISTING

ME MODIFY EXISTING

REX RELOCATE EXISTING

NEW WORK PLANS - EXISTING CONDITIONS DESIGNATIONS:

EX EXISTING TO REMAIN

ME MODIFY EXISTING

ER EXISTING RELOCATED

EXISTING DESIGNATIONS

NAC NOTIFICATION APPLIANCE POWER SUPPLY

LOC

FMCU

CONTROL MODULECM

1. KEYED NOTES ARE INDICATED ON PLANS BY SYMBOL

2. REFER TO HVAC MECHANICAL DRAWINGS FOR EXACT LOCATION OF DUCT SMOKE DETECTORS IN AIR HANDLING UNIT.

3. REFER TO SPRINKLER DRAWINGS FOR EXACT LOCATION AND QUANTITY OF SUPERVISED VALVES AND FLOW SWITCHES.

4. SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 72-2019, UFC-3-600-01, AND UFC 4-021-01.

5. LOCATE SMOKE DETECTORS MINIMUM 36 INCHES FROM HVAC DIFFUSERS.

6. LOCATE VISUAL DEVICES A MINIMUM OF 80" ABOVE FINISHED FLOOR OR 6" BELOW THE FINISHED CEILING, WHICHEVER IS LOWER. THE

MAXIMUM MOUNTING HEIGHT IS 96" ABOVE FINISHED FLOOR.

7. VISUAL DEVICE CANDELA RATING SHALL BE AS INDICATED ON DRAWING.

8. INSTALL ALL WIRING IN CONDUIT. CONDUIT MUST BE MINIMUM 3/4-INCH.

9. ALL DEVICES ARE TO BE PROTECTED DURING CONSTRUCTION.

10. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED DEVICES/APPLIANCES.

11. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE

RECORD DRAWINGS.

12. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. ALL CHANGES

SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS.

13. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION.

14. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT.

15. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER.

16. ANY SMOKE DETECTOR HEAD INSTALUED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST.

ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER.

17. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT

WORK IS NOT ACTIVELY BEING PERFORMED.

18. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC.

19. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC).

20. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN

ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE.

21. FIRE ALARM CABLE INSTALLED IN DUCTS. PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP.

22. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN

SHAFTS SHALL BE TYPE FPLR.

23. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS.

24. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70

ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE.

25. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS.

26. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT.

27. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING.

28. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS.

29. DEMOLISH ALL EXISTING FIRE ALARM AND MASS NOTIFICATION EQUIPMENT AS SHOWN ON DEMOLITION PLANS. ADDITIONALLY, REMOVE THE EXISTING FIRE ALARM RADIO ALARM TRANSCEIVER ANTENNA FROM THE ROOF OF THE BUILDING. PACKAGE ALL FIRE ALARM SYSTEM CONTROL

EQUIPMENT AND TURN OVER TO THE CONTRACTING OFFICER FOR SPARE PART STOCK.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

E

ER

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

FA001

SHERM

FI

R

E

AL

AR

M

G

EN

ER

AL

N O

TE

S

W

ES

T

PO

IN

T, N Y

N

EW

Y O

R K

D

IS

TR

IC

T

F

ED

E R

AL

P

LA

ZA

, N

EW

Y O

R K, N Y

JC

M

D

PF

JA

B

J

U

LY

W

2D S1

7D

RTA SUBMISSION

C

BU

P S

H

ER

M

AN

B

AR

R

AC

K S

W

2D S1

8F

PN

IS

SU

ED

B Y

AM

EN

D M

EN

T

/0

9/

BREAK GLASS SENSOR

PASSIVE INFRARED/MICROWAVE SENSOR

360° PASSIVE INFRARED/MICROWAVE SENSOR

REQUEST TO EXIT PUSH BUTTON

REQUEST TO EXIT PASSIVE INFRARED SENSOR

ACCESS CONTROL & INTRUSION DETECTION

CARD READER

DOOR STRIKE

ELECTROMAGNETIC LOCKING DEVICE

CCTV CAMERA, FIXED

SEISMIC SENSOR

CARD READER WITH KEYPAD

BALANCED MAGNETIC SWITCH

DURESS PANIC SWITCH

AREA NOTIFICATION EQUIPMENT

SECURITY PANEL

POWER SUPPLY

CELL BOOSTER ENCLOSURE

SECURITY ENCLOSURE

SIREN

VIDEO INTERCOM (MASTER)

MISCELLANEOUS SYSTEMS

TELEPHONE AND DATA COMMUNICATIONS

TELEPHONE TERMINAL BOARD (TB)

TELEPHONE TERMINAL CABINET (TC)

TELEPHONE WALL OUTLET

DATA WALL OUTLET

AV = AUDIO VISUAL

M = MODULAR OR SYSTEM FURNITURE

TV = TELEVISION

DATA OUTLET IN COMMON FLOOR BOX WITH ELECTRICAL OUTLET

COMBINATION TELEPHONE AND DATA WALL OUTLET

COMBINATION TELEPHONE AND DATA OUTLET IN COMMON FLOOR

BOX WITH ELECTRICAL OUTLET

EQUIPMENT RACK

MICROPHONE OUTLET CEILING

PUBLIC ADDRESS PUSHBUTTON

VOLUME CONTROL AND CHANNEL SELECTOR

CEILING MOUNTED SPEAKER

WALL MOUNTED SPEAKER

BUZZER SWITCH

TELEVISION OUTLET

TELEPHONE CEILING OUTLET

ELECTRIFIED LOCK SET

CCTV MONITORPRIMARY BONDING BUSBAR (PBB); SECONDARY BONDING BUSBAR (SBB)

BUILDING ENTRANCE TERMINAL

CCTV CAMERA, PAN-TILT-ZOOM

WIRELESS ACCESS POINT (WAP) CEILING OUTLET

COMBINATION TELEPHONE AND DATA CEILING OUTLET

CHIME

AMPLIFIER

BASKET CABLE TRAY

CONSOLIDATION POINT

TWO POST RELAY RACK

M

TELEPHONE OUTLET IN COMMON FLOOR BOX WITH ELECTRICAL OUTLET

SIPRNET WALL OUTLETS

POKE-THRU

WALL MOUNTED JUNCTION BOX WITH FLEXIBLE WHIP TO FURNITURE BASE

POWER FEED, MOUNT AT 18-INCHES ABOVE FINISHED FLOOR

FLOOR BOX FEED WITH FLEXIBLE WHIP TO FURNITURE BASE POWER FEED

POWER POLE FEED WITH FLEXIBLE WHIP TO FURNITURE BASE POWER FEED

LADDER CABLE TRAY

T

T

TP

BET

CP

SINGLE FACE DIGITAL CLOCK, 2 = DOUBLE FACE

PROGRAM BELL

PROGRAM BUZZER

MIC

PA

V

C

TV

AMP

CH

KEYPAD

ML

EL

DS

AUDIO SENSOR DEVICE

P

INTERCOM:

M = MASTER STATION

R = REMOTE STATION

VIDEO INTERCOM (REMOTE)

CELLULAR TRANSMITTER

SP

CBE

ENC

BADGING WORKSTATIONBWS

ALARM MONITORING WORKSTATIONAWS

ACCESS CONTROL SYSTEM PANELACS

INTRUSION DETECTION SYSTEM PANELIDS

SITE

EXISTING MANHOLE (CMH) OR EXISTING HANDHOLE (CHH)

NEW MANHOLE (CMH) OR NEW HANDHOLE (CHH)

COMMUNICATIONS DUCTBANK

EXISTING COMMUNICATIONS DUCTBANK

C

Cx

TELECOMMUNICATIONS SYMBOLS

110 BLOCKS110

MIC

MIC

MICROPHONE OUTLET FLOOR

MICROPHONE OUTLET WALL

C

ACEG ALTERNATING CURRENT EQUIPMENT GROUND

ACS ACCESS CONTROL SYSTEM

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

ANN ANNUNCIATOR

ARCH ARCHITECTURAL

AV AUDIO AND VISUAL

BAS BUILDING AUTOMATION SYSTEM

BATT BATTERY

B BACKBONE

BBC BACKBONE BONDING CONDUCTOR

BBV BACKBONE VOICE

BEPB BUILDING ENTRANCE PROTECTION BLOCKS

BFPP BACKBONE FIBER PATCH PANEL

BLDG BUILDING

BMS BALANCED MAGNETIC SWITCH

BVPP BACKBONE VOICE PATCH PANEL

C CONDUIT

CAB CABINET

CAT CATEGORY

CCTV CLOSED CIRCUIT TELEVISION

CFCI CONTRACTOR FURNISHED CONTRACTOR

INSTALLED

CLG CEILING

CMH COMMUNICATIONS MANHOLE

COB CENTER OF BOX

COMM COMMUNICATIONS

CONST CONSTRUCTION

CONT CONTINUATION

DIST DISTRIBUTION

DWG DRAWING

EF ENTRANCE FACILITY

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

EQPT EQUIPMENT

EXIST EXISTING

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

FIXT FIXTURE

FLR FLOOR

FO FIBER OPTIC

GFGI GOVERNMENT FURNISHED GOVERNMENT

INSTALLED

HCPP HORIZONTAL COPPER PATCH PANEL

HFPP HORIZONTAL FIBER PATCH PANEL

HOV HORIZONTAL VOICE

HVPP HORIZONTAL VOICE PATCH PANEL

HWPP HORIZONTAL WIRELESS PATCH PANEL

IDS INTRUSION DETECTION SYSTEM

ISP INDOOR CABLE PLANT

JB JUNCTION BOX

MFR MANUFACTURER

MH MOUNTING HEIGHT

MMF MULTI MODE FIBER

MTD MOUNTED

NC NURSE CALL

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OH OVERHEAD

OSP OUTDOOR CABLE PLANT

PA PUBLIC ADDRESS

PB PULL BOX

PBB PRIMARY BONDING BUSBAR

PBX PRIVATE BRANCH EXCHANGE

PC PERSONAL COMPUTER

PLAS PLASTIC

PP PATCH PANEL

PR PAIR

PWR POWER

QTY QUANTITY

RBB RACK BONDING BUSBAR

RBC RACK BONDING CONDUCTOR

RECP RECEPTACLE

REQD REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RSC RIGID STEEL CONDUIT

RU RACK UNIT

SBB SECONDARY BONDING BUSBAR

SCRT SECURITY

SECT SECTION

SPEC SPECIFICATION

SMF SINGLE MODE FIBER

SP SERVICE PROVIDER

SURF SURFACE

SW SWITCH

SYM SYMMETRICAL

SYS SYSTEMS

TBB TELECOMMUNICATIONS BONDING BACKBONE

TBC TELECOMMUNICATIONS BONDING CONDUCTOR

TEBC TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR

TEL TELEPHONE

TELCOM TELECOMMUNICATIONS

TER TELECOMMUNICATIONS EQUIPMENT ROOM

TR TELECOMMUNICATIONS ROOM

TYP TYPICAL

UG UNDERGROUND

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

WP WEATHERPROOF

XFR TRANSFER

XP EXPLOSION PROOF

DATA OUTLETS

NC OUTLETS

TELEPHONE OUTLETS

TELEPHONE AND DATA OUTLETS

COUNTER TOP OUTLETS (CT)

WIRELESS ACCESS POINT

HORN SPEAKERS

TELEVISION OUTLET (TV)

CARD READER BACK BOX

SPEAKER VOLUME CONTROL

18-INCHES

48-INCHES

48-INCHES

18-INCHES

8 INCHES ABOVE COUNTER

AT FINISHED CEILING

AS INDICATED

60-INCHES

40-INCHES

40-INCHES

1. ALL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES SHOWN ARE NOT

NECESSARILY USED ON THIS PROJECT.

2. REFER TO ONE-LINE DIAGRAMS FOR CABLE SIZES, CONDUIT SIZES, AND DEVICES NOT

SHOWN ON PLANS.

3. MOUNTING HEIGHTS FOR CEILING MOUNTED DEVICES ARE TO THE BOTTOM OF THE

DEVICE, UNLESS OTHERWISE NOTED.

4. MOUNTING HEIGHTS ABOVE FINISHED FLOOR, TO CENTERLINE OF DEVICE, ARE AS

FOLLOWS, UNLESS OTHERWISE NOTED:

5. ALL EXPOSED CABLES IN THE TELECOM EQUIPMENT ROOM (TER) AND TELECOM ROOMS

(TR) MUST BE INSTALLED INSIDE POLYETHYLENE TEREPHTHALATE (PET) EXPANDABLE

BRAIDED SLEEVING TO PROVIDE A PROFESSIONAL LOOK ON FINISHED PRODUCT.

PROVIDE YELLOW COLORED SLEEVING FOR DATA CABLING AND GREEN COLORED

SLEEVING FOR VOICE CABLES.

6. CONTRACTOR MUST SUPPLY FACTORY TERMINATED FIBER OPTIC AND CAT 6 PATCH

CORDS FOR EACH DATA PORTS AND CAT 6A FOR WIRELESS PORTS AT THE TELECOM

EQUIPMENT ROOM (TER) AND TELECOM ROOMS (TR) ON EACH FLOOR FOR A COMPLETE

AND WORKING TURN-KEY COMMUNICATIONS SYSTEM. LENGTH OF PATCH CORDS TO BE

DETERMINED BY USMA/NEC PROJECT MANAGER. PATCH CORDS MUST BE COLOR-

CODED TO MATCH WITH HORIZONTAL CABLE COLORS. CONTRACTOR MUST ALSO

SUPPLY 200 EACH 5 FEET, AND 200 EACH 7 FEET GREEN JACKET CAT 6 PATCH CORDS

FOR THE OUTSIDE PLANT (OSP) COPPER CABLE CROSS CONNECTION IN THE TELECOM

ROOMS.

7. THE FOLLOWING COLOR CODED MUST BE USED FOR HORIZONTAL WIRING:

• GREEN (JACKET, JACKS PATCH CORDS) FOR VOICE

• BLUE (JACKET, JACKS, PATCH CORDS) FOR WREN DATA

• YELLOW (JACKET, JACKS, PATCH CORDS) FOR NIPR DATA

• ORANGE (JACKET, JACKS, PATCH CORDS) FOR WREN WIRELESS

• WHITE (JACKET, JACKS, PATCH CORDS) FOR CCTV CAMERAS

• GRAY (JACKET, JACKS, PATCH CORDS) FOR CHC DATA

• LT BLUE (JACKET, JACKS, PATCH CORDS) FOR CHC WIRELESS

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

T-001

LEE

T E

L E

C O

M M

U N

IC

A

T

IO

N S

S Y

M B

O L S

A

B B

R E

V

IA

T

IO

N S

A N

D G

E N

E R

A L N

O T

E S

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

S L H

C A

T

J D

H

J

U L Y

W D

S D

RTA SUBMISSION

C B

U P

L E

E B

A R

R A

C K

S

W D

S F

P N

TELECOMMUNICATIONS ABBREVIATIONS TELECOMMUNICATIONS GENERAL NOTES

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1 /2

C

C P

C

C

O

M

M

C

O

M

M

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M

M

C O

M

M

C O

M

M

C O

M

M

C O

M M

C O

M M

C O

M M

CO

M

M

C O

M M

COMM

COMM

COMM

COMM

COMM

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C

C

CYBER & ENGINEERING ACADEMIC CENTER

X X X X X X X X

X

X

X

X

X

X

X

X X

X

C O

M M

COMM C

C

C

O

M

M

C

O

M

M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C O

M M

C O

M M

C O

M M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

COMM

COMM

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C O

M M

C O

M M

C

O

M

M

C O

M M

C O

M M

C O

M M

COMM

COMM

C O

M M

VAULT

MH 22

MH 3

MH X6

MH X5

MH X4

MH 2C

MH 2A

MH 2

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

COMM COMM COMM COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C

O

M

M

C

O

M

M

COMM

COMM

COMM

COMM

COMM

C

O

M

M

MH 3E

C

O

M

M

C

O

M

M

C

O

M

M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

MH X3

MH 3B

MH 3A1

MH 3A

C

C

C

C

C

C

C

C

C

C

C

C

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

MH35B

EXISTING

MH34B

MH34

C

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C

O

M

M

C

O

M

M

C

O

M

M

C

O

M

M

TER

MH35C

EXISTING

COMM COMM COMM

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

TAYLOR HALL

(EX) CABLE VAULT

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

CEAC

1 C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

I S

S U

D

B

Y

A

M E

N D

M E

N T

C A

T

S L H

O V

E R

A L L

S

I T

E

P

L A

N

L E

E

B

A R

R A

C K

S

T E

L E

C

TS100

30' 60'0

N

A1

TELECOM OVERALL SITE PLAN - LEE BARRACKS

SCALE: 1"=30'

KEY NOTES

1 NEW FIBER OPTIC CABLES IN EXISTING

DUCTBANK/MANHOLE SYSTEM. REFERENCE

ONE-LINE DIAGRAM T-600 FOR CABLE

REQUIREMENTS. COORDINATE WITH EXISTING

CONDITIONS AND BASE COMM FOR EXACT

ROUTING OF NEW CABLE.

D A

T E

M A

R K

D E

S C

R I P

T I O

N

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

SHEET ID

W D

S F

U S

A

R M

Y

C

O R

F

E

N G

I N

E E

R S

US Army Corps of Engineers

N E

W

Y

O R

K

D

I S

T R

I C

T

F

E D

E R

A L

P

L A

Z A

N

W

R

K

N

Y

W D

S D

J U

L

A N

S I

D

W E

I N

T

N

Y

C B

U

L

E

B

A R

R A

C K

RTA SUBMISSION

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

LEE

A1

TS101

W/D W/DW/DW/DW/D

CC

C x1 x2 x3 x4 x5 x6 x7 x8 x9 x10 x11 x12 x13 x14 xL xK xJ xH xG

ELEV.

LE-2-1

STAIR 1

LS-2-1

STAIR 2

LS-2-2

CADET ROOM

L2015

LAUNDRY

L203

COLLABORATION

ROOM

L205

CADET ROOM

L2001

CORRIDOR

L200

CADET ROOM

L2002

CADET ROOM

L2003

CADET ROOM

L2004

CADET ROOM

L2005

CADET ROOM

L2006

TAC

L2007

TAC

L2008

TAC

L2009

CADET ROOM

L2010

CADET ROOM

(ABA)

L2011

CADET ROOM

L2012

CADET ROOM

L2013

CADET ROOM

L2014

MEN'S ROOM

L208

ELEC.

L201

WOMEN'S

ROOM

L202

TELECOM

L206

JANITOR

L204

18"W X 2"H CABLE TRAY

MOUNTED AT 7'-4" AFF

T-401

B8

ECS

DAS

ECS

DAS2

TV

AV

T-401

C8

04 8 16268

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

T-102

LEE

S E

C O

N D

F L O

O R

C O

M M

U N

IC

A

T

IO

N S

P L A

N

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

S L H

C A

T

J D

H

J

U L Y

W D

S D

RTA SUBMISSION

C B

U P

L E

E B

A R

R A

C K

S

W D

S F

P N

1/8" = 1'-0"C1

SECOND FLOOR - COMMUNICATIONS

PLAN

MOUNT AT 48 INCHES ABOVE FINISHED FLOOR FOR LAUNDRY PAYMENT

SYSTEM. COORDINATE LOCATION OF UNIT.

ALL OUTLETS AT DESKS IN CADET ROOMS ARE MOUNTED AT 40-INCHES

ABOVE FINISHED FLOOR.

KEY NOTES

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1 /2

W/DW/D

CC

C x1 x2 x3 x4 x5 x6 x7 x8 x9 x10 x11 x12 x13 x14 xL xK xJ xH xG

CADET ROOM

L3015

COLLABORATION

ROOM

L305a

CADET ROOM

L3001

CORRIDOR

L300

CADET ROOM

L3002

CADET ROOM

L3003

CADET ROOM

L3004

CADET ROOM

L3005

CADET ROOM

L3006

CADET ROOM

L3007

CADET ROOM

L3008

CADET ROOM

L3010

CADET ROOM

L3011

CADET ROOM

L3012

CADET ROOM

L3013

CADET ROOM

L3014

CADET ROOM

L3016

STAIR 2

LS-3-2

ELEV.

LE-3-1

STAIR 1

LS-3-1

WOMEN'S

ROOM

L302

ELEC.

L301

STORAGE

L304

18"W X 2"H CABLE TRAY

MOUNTED AT 7'-4" AFF

CCQ

L3009

TELECOM

L306

MEN'S ROOM

L308

JANITOR

L307

COLLABORATION

STORAGE

ROOM

L305b

LAUNDRY

L303

ECS

DAS

ECS

DAS2 2

TV

AV

T-402

A1

T-402

D1

04 8 16268

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

T-103

LEE

T H

IR

D

F L O

O R

C O

M M

U N

IC

A

T

IO

N S

P L A

N

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

S L H

C A

T

J D

H

J

U L Y

W D

S D

RTA SUBMISSION

C B

U P

L E

E B

A R

R A

C K

S

W D

S F

P N

1/8" = 1'-0"C1

THIRD FLOOR - COMMUNICATIONS PLAN

KEY NOTES

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1 /2

MOUNT AT 48 INCHES ABOVE FINISHED FLOOR FOR LAUNDRY PAYMENT

SYSTEM. COORDINATE LOCATION OF UNIT.

ALL OUTLETS AT DESKS IN CADET ROOMS ARE MOUNTED AT 40-INCHES

ABOVE FINISHED FLOOR.

BLANK

COVER #8B

1-1/4 INCH HOUSING

ASSEMBLY AND SIX

PORT OPENING PLATE

FOR COMMUNICATION

CABLES AND JACKS

1-1/4 INCH HOUSING ASSEMBLY AND

1-9/16 INCH RECEPTACLE OPENING

PLATE FOR AUDIO VISUAL CABLES

20A DUPLEX RECEPTACLE

(TYP OF 2) SEE ELECTRICAL

NOTE: COVERS NOT SHOWN FOR CLARITY

AV

CHC

DATA CAT 6 GRAY

CABLE AND JACKS

COMBINATION DATA AND ELECTRICAL

SYSTEM FURNITURE POKE-THRU

M

CHC/NC

2-INCH GROMMET

FOR GFGI CABLING

VOICE CAT 6 GREEN

CABLE AND CAT 6

GREEN JACK

8-INCH POKE-THRU

SEE ELECTRICAL

3-PORT PLASTIC

FACE PLATE

DATA 1 BLANK DATA 2

M

3 PORT MODULAR FURNITURE DATA OUTLET

DATA CAT 6 CABLE

AND JACK, BLUE

DATA CAT 6 CABLE

AND JACK, BLUE

AV OUTLET

TV

1 1/4-INCH CONDUIT

STUBBED ABOVE CEILING

AV OUTLET

AV

2-INCH CONDUIT STUBBED

ABOVE CEILING

1 1/4-INCH

GROMMET 2-INCH

GROMMET

4 11/16" SQUARE x 2 1/8" DEEP

BACKBOX WITH SINGLE GANG

PLASTER RING AND HIGH IMPACT

PLASTIC GROMMET FACEPLATE

4 11/16" SQUARE x 3 1/4" DEEP

BACKBOX WITH DOUBLE GANG

PLASTER RING AND HIGH IMPACT

PLASTIC GROMMET FACEPLATE

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

T-502

LEE

D E

T A

IL

S

F

L O

O R

O U

T L E

T S

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

S L H

C A

T

J D

H

J

U L Y

W D

S D

C B

U P

L E

E B

A R

R A

C K

S

W D

S F

P N

1. TERMINATE ALL COPPER CABLES ON JACKS WITH T568A PIN-OUT.

NOT TO SCALEA1

AUDIO VISUAL POKE-THRU DEVICES

NOT TO SCALED1

MODULAR FURNITURE OUTLET

GENERAL NOTES

NOT TO SCALEC4

TV AND AV OUTLETS

IS

S U

E D

B Y

A M

E N

D M

E N

T

/1 /2

(EX) MH-3CMH-X4

S

M F

O S

P

S

M F

O S

P

F O

C B

-1

DUCTBANK

12 SMF OSP(FOC B600, 1-12)

(EX) MH-2 (EX) MH-2A

EXISTING DUCTBANK

48 SMF ISP/OSP 48 SMF ISP/OSP

(EX) MH-22

EXISTING DUCTBANK

B2 TELECOM RM 29C

TAYLOR HALL (B600)

BFPP

EXISTING RACK

BFPP

EXISTING RACK

48 SMF ISP/OSP

EXISTING DUCTBANK

REFERENCE SHEET T-601

FOR CONTINUATION

CABLE VAULT

200 PR OSP (CA17, 801-1000)

CMH-X5

(EX) MH-35B

(EX) MH-35C

EXISTING DUCTBANK

S

M F

O S

P

144 SMF OSP 144 SMF OSP

EXISTING DUCTBANK EXISTING DUCTBANK

EXISTING TER

BFPP

EXISTING RACK

E X

IS

T

IN

G

D U

C T

B A

N K

12 MMF 62.5 OSP (FOC CB1, 133-144)

24 MMF 62.5 OSP (BIT)

24 SMF OSP (FOC 600D1, 73-96)

48 SMF OSP

B2 DAS RM

D U

C T

B A

N K

S

M F

O S

P

SPLICE EXISTING

FIBER AND

COPPER CABLES

48 SMF OSP

72 SMF OSP

(E X

)4 P

R O

S P

C

A -1

(E X

M

M F

.5

O S

P F

O C

C B

-1

P U

L L I N

F R

O M

C M

H -X

M

M F

.5

O S

P

B

IT

S

M F

O S

P

F O

C

D

-9

12 SMF OSP (FOC B600, 1-12)

D U

C T

B A

N K

S

M F

I S

P /O

S P

TO SHERMAN BARRACKS

DUCTBANK

24 SMF OSP (FOC 600D1, 73-96)

EXISTING SPLICE

S

M F

O S

P

F O

C B

-1

12 SMF OSP(FOC B600, 1-12) 12 SMF OSP(FOC B600, 1-12) 12 SMF OSP(FOC B600, 1-12)

(EX) 2' X 3' X 2'

GS HANDHOLE

SPLICE

(EX) 12 PR COPPER CABLE (GS)

(EX) 12 SMF CABLE (GS)

(EX) BET)

(EX) FPP

(EX) GUARD SHACK (GS)

12 PR BET

1U FPP

(EX) B606

(EX) MH 34

(WALL MTD)

(EX. RACK MTD)

(EX) TER

PROVIDE PATCH CORDS TO RESTORE LAN, VOICE AND CCTV

CONNECTIONS AT GS. COORDINATE WITH GVERNMENT.

PROVIDE PATCH CORDS TO RESTORE LAN, VOICE AND CCTV

CONNECTIONS AT GS. COORDINATE WITH GVERNMENT.

12 PR COPPER CABLE (GS)

12 SMF CABLE (GS)

DISCONNECT AND REMOVE CABLES FROM B606 AND

CONNECT CABLES TO LEE PRIOR TO B606 DEMOLITION

S

M F

A N

D

P

R C

O P

P E

R C

A B

L E

G

S

P

R C

O P

P E

R C

A B

L E

G

S

S

M F

C A

B L E

G

S

12 SMF AND 12 PR COPPER CABLE (GS)

144 SMF OSP

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .