Lee Barracks Electrical Drawings for Amendment.pdf
PDF 16 MB Posted
- Solicitation number
- W912DS21B0004
About this file
This document provides details on a federal contract opportunity for repair work at two military barracks buildings. The U.S. Army Corps of Engineers, New York District intends to issue a solicitation by August 6, 2021 seeking a firm-fixed price contract to repair Buildings 740 and 738 at Lee and Sherman Barracks, including full interior and exterior renovations, mechanical, electrical and plumbing system replacements, and site work. The estimated value of the contract is between $100-200 million, with a period of performance of approximately 1034 calendar days from notice to proceed. The work includes repairing 192 cadet rooms and adding a health clinic at Building 740, as well as repairing 152 cadet rooms at the larger Building 738 totaling over 180,000 square feet. Bidders must be registered in the System for Award Management and monitor the website for any amendments, with proposals due approximately 30 days after issuance. The North American Industry Classification code is 236220.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W/D W/DW/DW/DW/D
SM
SM SM SM SM SM
SM SM SM SM SM SM SM
SM
SM
CC FECFEC
SM
S M
SM
C
MD MD
MD MD
MD
J
MD MD
J
J
J J J J J
J
J
J
J J J J J J
JJ
METERING J
J xG x1 xL xH xJ xK x2 x3 x5 x6 x7 x8 x9 x14x10 x11 x12 x13 x11A x12A
+40 +40
+40
3 4
ELEC.
L201 E-401
C2
USB
USB
USB
USB
AF
RP2A: 17
USB
USB
USB
USB
AF
RP2A: 17
USB
USB
USBUSB
USB
USB
AFAF
RP2A: 17
USB
USBUSB
USB
RP2A: 12
AF
USB
USBUSB
USB
AF
USB
USB
USB
USB
USB
USB
AFAF
USB
USB
USBUSB
USB
USB
USBUSB
USB
USB
AFAF
USB
USBUSB
USB
USB
USB
AF
USB
USB
AF
USB
USB
+40
+40
+40
RP2B: 18
+40
RP2B: 24 RP2B: 15
+40 +40
+40 +40
+40 +40
RP2B: 9
+40
+40 +40
+40
RP2A: 9
+40 +40
+40 +40
+40
+48"
+36
DEDICATED FOR CORRIDOR
HEATER
AF
CADET ROOM
L2015
MEN'S ROOM
L208
STAIR 2
LS-2-2
ELEV.
LE-2-1
TELECOM
L206
COLLABORATION
ROOM
L205
LAUNDRY
L203
JANITOR
L204
CORRIDOR
L200
DH
DH
STAIR 1
LS-2-1
WOMEN'S
ROOM
L202
CADET ROOM
L2001
CORRIDOR
L200
CADET ROOM
L2002
CADET ROOM
L2003
CADET ROOM
L2004
CADET ROOM
L2005
CADET ROOM
L2006
TAC
L2007
TAC
L2008
TAC
L2009
CADET ROOM
L2010
CADET ROOM
(ABA)
L2011
CADET ROOM
L2012
CADET ROOM
L2013
CADET ROOM
L2014
FCU
FCU
+36
A1
E-402E-102
A1
E-402E-102
A4
E-402E-102
A4
E-402E-102
+20
USB
RP2A: 19
RP2A: 19
RP2A: 19
RP2A: 17
RP2A: 2
RP2A: 2
RP2A: 2
2#12 & #12G, 3/4"C
RP2B: 7
RP2B: 12
RP2B: 12
RP2B: 12
C
C
CC
C
RP2B: 13
RP2B: 13
2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C
RP2B: 6RP2B: 6
RP2B: 3
RP2B: 11
RP2B: 16
RP2B: 16
RP2B: 16
RP2B: 11
C
RP2B: 16
RP2A: 33,35
RP2A: 30,32
RP2A: 29,31
RP2A: 26,28
RP2A: 25,27
RP2B: 12
RP2B: 4
RP2B: 1
RP2B: 4
RP2A: 21
RP2A: 21
RP2A: 21
+20
RP2A: 7
RP2A: 7
USB
RP2A: 7
+ RP2A: 23
RP2A: 23
RP2A: 4
RP2A: 4
RP2A: 23
+20
USB
RP2A: 4
USBUSBUSB
RP2A: 14
RP2A: 14
RP2A: 14
+40
RP2A: 9
+20+20+20+20+20
RP2A: 9RP2A: 6RP2A: 11RP2A: 13RP2A: 15RP2B: 8
USBUSBUSBUSB
+20+20+20+20+20+20
USBUSBUSBUSB
RP2B: 9RP2B: 5RP2B: 26RP2B: 15RP2B: 24
RP2A: 16RP2A: 18
RP2A: 6
RP2A: 6
RP2A: 16
RP2A: 16
RP2A: 12
RP2A: 11
RP2A: 12
RP2A: 12
RP2A: 11
RP2A: 18
RP2A: 18
RP2A: 13
RP2A: 3
RP2A: 15
RP2A: 5
RP2B: 8
RP2A: 5RP2B: 14RP2B: 22RP2B: 23RP2B: 20
RP2B: 17
RP2B: 17
RP2B: 4
USB
+40
+40
USBUSB
+40 +42
AF
USB
USB
RP2A: 3
USB
USB
RP2B: 14RP2B: 22
RP2B: 22
RP2B: 14
RP2B: 9
+40
RP2A: 15
+40
+40
RP2A: 13
USB
3#6 & #10G, 1"C3#6 & #10G, 1"C
RP2B: 4
RP2B: 1
RP2B: 3
RP2B: 17
RP2B: 17
RP2B: 5
RP2B: 26
RP2B: 26 RP2B: 5
RP2B: 23
RP2B: 23
RP2B: 20
RP2B: 17
+40
RP2B: 20
+40
RP2B: 24
+40
RP2B: 21
RP2B: 21
RP2B: 21
RP2B: 17
RP2B: 4
RP2B: 19
RP2B: 19
RP2B: 19
+40 +20
USB
RP2B: 18
RP2B: 3
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
ABA TOILET
ROOM
LS207
+40
RP2B: 8
USB
RP2B: 12
RP2B: 18
MP2: 12,14,16 MP2: 15,17,19
MP2: 7
MP2: 2MP2: 7
MP2: 3
MP2: 4MP2: 4
MP2: 8MP2: 8
MP2: 9
MP2: 9 MP2: 13MP2: 10
TP2: 8
MP2: 6
C
RP2B: 13
RP2B: 11
+60
RP2B: 2
MP2: 5
MP2: 5
MP2: 5
MP2: 5 2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
EWC
MP2: 1
2#12 & #12G, 3/4"C
C CC
RP2A: 24 RP2A: 20 RP2A: 22
(TYP)
(TYP)
(TYP)
6 6 6
6 6
6 6
(TYP)
(TYP)
(TYP)
FCU
FCU
FCU
FCU
FCU
1 FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
RP2B: 13
C C
C
RP2A: 24
COPIER
TV
USB
USB
RP2A: 3RP2B: 10
RP2A: 5
USB
AF
RP2B: 10
TYP. FOR ALL
ROOMS
TP2: 2
C
RP2B: 13
RP2B: 7
C C
RP2A: 20 RP2A: 22
KIOSK
RP2B: 7
+60
RP2A: 10
RP2A: 8
DESV
FCU
E-402
G1
DESV
TWO OUTLETS (TV AT +60
& ANOTHER +18")
+40
+40
RP2B: 15
+40 +40
+40 +40
+40 +42
+40
+40
+40 +40
+40
+40 +40
+40 +40
+40
+40
USB
+40
+40+40
RP2B: 10
+40 +40
+40
+40
+40 +40 x12Bx4
AF
AF
AF
AF
AF
AF
AF AF
AF
AF
AF
AF
AF
AF +40
AF
(TYP. FOR ALL)
3#6 & #10G, 1"C
MP2: 18,20,22
L15-50RL15-50R L15-50R
KEYED NOTES SEAL
1. FOR GENERAL DEMOLITION NOTES, ABBREVIATIONS, FEEDER SCHEDULE, MOUNTING
HEIGHT GRAPH, AND DRAWING INDEX, REFER TO SHEET E-001. FOR GENERAL SYMBOLS
AND FEEDER ID SCHEDULE, REFER TO SHEETS E-002 AND E-003.
2. CIRCUIT OUTLETS FROM SAME FLOOR ELECTRICAL ROOM(S). BRANCH CIRCUIT (HOME
RUN) IDENTIFIED WITH BOUNDARY LINES AND CIRCUITED BY DISPLAYING BRANCH
PANEL NAME AND CIRCUIT NUMBER, UON.
3. THE MINIMUM AMPACITY OF THE OCPD FOR ALL POWER AND LIGHTING BRANCH
CIRCUITS BE 20A/1-POLE, 125V RATED DEVICE, UON. DUPLEX AND SINGLE
RECEPTACLES, 125V, 20-AMPERES, IN ANY AREAS, OTHER THAN ELECTRICAL,
MECHANICAL, & TELECOM ROOMS AND JANITORIAL CLOSETS, MUST USE TAMPERED
RESISTANT DUPLEX (OR QUADRUPLEX) RECEPTACLES.
4. GENERAL BRANCH WIRING CONNECTION TO GFI (GROUND FAULT INTERRUPTER)
OUTLETS TO THE LINE SIDE TERMINALS AND DAISY-CHAIN WIRE CONNECTIONS WITH
MECHANICAL WIRE SPLICER. NO GFI DEVICE CONNECTION ON THE LOAD SIDE
TERMINALS, OR FED-THROUGH TO OTHER DOWN-STREAM DUPLEX OUTLETS OR OTHER
GFI OUTLETS.
5. COORDINATE LOCATION AND HEIGHT OF OUTLETS AND DEVICES WITH CASEWORK,
FURNITURE, AND PARTITION ELEVATIONS. REFER TO ARCHITECTURAL AND INTERIOR
ELEVATIONS, DETAILS, AND MOUNTING INSTALLATION INFORMATION. NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES BEFORE INSTALLATION OF ANY
CONDUIT, OUTLET BOXES, AND/OR SUPPORTING HARDWARE.
6. THE MAXIMUM 600V RATED INSULATED CONDUCTOR RUN LENGTH, IN METALLIC CONDUIT,
FOR ALL POWER AND LIGHTING CIRCUITS FED WITH A 20A/1-POLE, 125V OR AT 208V FOR
20A/2-POLE, RATED CIRCUIT BREAKER DEVICE (CALCULATED AT 16 AMPERES MAX PER
CIRCUIT PER NEC), UON, LIMITED VOLTAGE DROP LESS THAN 3% ARE:
A. LESS THAN 60 FT - 2#12 AWG & 1#12G, IN 1/2" EMT.
B. MORE THAN 60 FEET, LESS THAN 100FT - 2#10 AWG & 1#10G, IN 1/2" EMT.
C. MORE THAN 100 FEET, LESS THAN 150FT - 2#8 AWG & 1#10G, IN 3/4" EMT.
D. MORE THAN 150 FEET, LESS THAN 250FT - 2#6 AWG & 1#10G, IN 3/4" EMT.
7. COORDINATE WITH MECHANICAL FOR LOCATION OF ALL HVAC CONTROL DEVICES,
MOTORIZED DAMPERS, OR CONTROL CABINETS TO PROVIDE CONTROL POWER IN LOCAL
JUNCTION BOX, ROUTING OF CONDUIT AND CONDUCTORS AS RATED FOR SHEET NOTE 6
ABOVE, UNLESS REQUIRED, PLENUM RATED CONDUCTORS FOR SPACES ABOVE
ACCESSIBLE SUSPENDED CEILINGS. PROVIDE 120V CIRCUIT FOR PLUMBING ELECTRONIC
TAP PRIMERS.
8. CADET ROOM BRANCH CIRCUITS MUST BE PROTECTED BY ARC-FAULT RECEPTACLES IN
ACCORDANCE WITH NEC 210.12 (A)(5). MARK THE FIRST OUTLET IN THE BRANCH CIRCUIT AS
THE FIRST OUTLET OF THE CIRCUIT.
9. RECESSED OUTLET BOXES MOUNTED IN SAME WALL FROM APPOSING SIDES TO BE
SEPARATED MINIMUM 6-INCH TO AVOID BACK-TO-BACK OUTLET BOX CONFLICTS.
10. EXTERIOR OUTLETS MUST BE CUT INTO GRANITE/MASONRY AND RACEWAY CONCEALED
WITHIN CONSTRUCTION.
SHEET NOTES
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PLAN NORTHPART APART B
KEY PLANKEY PLAN
PART APART B
E-102
LEE
S E
C O
N D
F L O
O R
P O
W E
R P
L A
N
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J A
K
B E
B
M M
B
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"C1
POWER FLOOR PLAN - SECOND
LEVEL
1 COORDINATE MOUNTING HEIGHT WITH COUNTERTOP AND BACKSPLASH FOR GFI, TAMPER-RESISTANT, OUTLETS. CRCUIT AS SHOWN. TYPICAL
IN ALL REST/SHOWER ROOMS.
2 COORDINATE MOUNTING HEIGHT WITH COUNTERTOP AND BACKSPLASH FOR GFI, TAMPER-RESISTANT, OUTLETS. CIRCUIT AS SHOWN. TYPICAL
IN ALL CADET ROOMS.
3 COORDINATE MOUNTING HEIGHT OF DEDICATED OUTLET WITH HVAC/HEATER/MAINTENANCE EQUIPMENT IN COORIDOR. CIRCUIT AS SHOWN.
TYPICAL THROUGHOUT CORRIDORS.
4 SINGLE RECEPTACLE OUTLET, MOUNTED AT HEIGHT INDICATED ON SYMBOL LEGEND (E-001). COORDINATE LOCATION WITH ARCHITECHAL
SHEETS WITH FIRE RATED WALLS. CIRCUIT AS SHOWN.
5 PROVIDE 30A/3W/250V DRYER OUTLET. COORDINATE LOCATION WITH ARCHITECTUAL DRAWINGS. CIRCUIT AS SHOWN. TYPICAL IN LAUNDRY
AREA.
6 COORDINATE MOUNTING HEIGHT OF MOTOR-RATED DISCONNECT SWITCH (UNLESS OUTLET IS INDICATED) WITH HVAC EQUIPMENT AT CEILING.
CIRCUIT AS SHOWN. TYPICAL THROUGHOUT ALL FLOORS.
7 COORDINATE MOUNTING HEIGHT AND QUANTITY OF JUNCTION BOX FOR EACH HVAC MOTORIZED DAMPER IN SHAFT. CIRCUIT AS SHOWN.
TYPICAL THROUGHOUT EACH FLOOR.
8 FLOOR BOX OUTLET. COORDINATE LOCATION WITH ARCHITECTUAL AND INTERIOR FURNITURE DRAWINGS. CIRCUIT AS SHOWN. TYPICAL IN
THIS AREA.
9 COORDINATE MOUNTING HEIGHT AND LOCATION OF JUNCTION BOX FOR SECURITY EQUIPMENT OR DEVICE WITH TELECOM/SECURITY
DRAWINGS.
10 COORDINATE LOCATION OF SUB-METERING WORKSTATION / DISPLAY PANEL WITH INTERIORS. SEE GENERAL NOTE 24, E-002 FOR
SUB-METERING REQUIREMENTS.
11 IN CADET ROOMS ONLY - OUTLETS IDENTIFIED WITH "AF" ARE CIRCUIT HOMERUNS. SEE PANELBOARD SCHEDULES FOR IDENTIFIED CIRCUITS
PROTECTED BY ARC FAULT CIRCUIT BREAKERS. CIRCUIT AS SHOWN.
IS
S U
E D
B Y
A M
E N
D M
E N
T
/1
/2
W/DW/D
SM SM
SM
SM SM SM SM SM SM SM SM SM SM SM SM
C C
FEC
FECFEC
S M
SM
SM
SM
C
MD MD
MD
MD
MD
JJ
J J J J J J J
JJ
J J J J J J
JJ
J
METERING
J xG x1 xL xH xJ xK x2 x3 x5 x6 x7 x8 x9 x14x10 x11 x12 x13 x11A x12A
+40 +40
+40
2 3
TYP TYP
TYP
USB
USB
AF
AF AF AF
AF AF AF AF AF
AF AF AF AF
AF
AF
USB
+42
RP3B: 22
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB USB
USB USB
USB
USB
USB USB
USB
USB
USB USB
USB USB
USB USB
USB USB
USB USB
USB
USB
USB
+40 +40
+40
+40
+40 +40
+40 +40
+40 +40
+40 +40
+40
+40
+40 +40
+42 +42
+40 +40
+40 +40
+40 +40
+40
+42
RP3A: 7
USB
+40
AF
USB
USB
USB
USB
+40
+40
E-401
F4
DEDICATED FOR CORRIDOR
HEATER
DH
CADET ROOM
L3001
WOMEN'S
ROOM
L302
STAIR 1
LS-3-1
COLLABORATION
STORAGE
ROOM
L305b
COLLABORATION
ROOM
L305a
STORAGE
L304
LAUNDRY
L303
CCQ
L3009
TELECOM
L306
JANITOR
L307
MEN'S ROOM
L308
STAIR 2
LS-3-2
ELEV.
LE-3-1
CORRIDOR
L300
CORRIDOR
L300
CADET ROOM
L3002
CADET ROOM
L3003
CADET ROOM
L3004
CADET ROOM
L3005
CADET ROOM
L3006
CADET ROOM
L3007
CADET ROOM
L3008
CADET ROOM
L3010
CADET ROOM
L3011
CADET ROOM
L3012
CADET ROOM
L3013
CADET ROOM
L3014
CADET ROOM
L3016
CADET ROOM
L3015
ELEC.
L301
DH
FCU
+48
+36
FCU
+36
C
C
C C
C
C
CUSB
USB
RP3B: 5
USB
USB
USB
USB USB
2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C2#12 & 12G, 3/4"C
2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C
3#6 & 10G, 1"C 3#6 & 10G, 1"C
RP3B: 11RP3B: 11
+20
USB
+42
RP3B: 22
RP3B: 15
RP3B: 15
RP3B: 27
RP3B: 15
RP3A: 26
TYP
RP3A: 26
RP3B: 1
RP3B: 1
RP3A: 26
+20 +20 +20 +20 +20 +20 +20 +20 +20 +20 +20 +20 +20
+20+20
USB USB
USBUSBUSBUSBUSBUSBUSBUSBUSBUSBUSBUSBUSB
RP3A: 5
RP3A: 5
RP3A: 4
RP3A: 7
+42
RP3A: 7
RP3A: 10
RP3A: 26
RP3A: 19
RP3A: 19
RP3A: 4
RP3A: 4
RP3A: 16RP3A: 18
RP3A: 19
RP3A: 6
RP3A: 6
RP3A: 6
RP3A: 25
RP3A: 25
RP3A: 25
RP3A: 16
RP3A: 16
RP3A: 18
RP3A: 18
RP3A: 5
RP3A: 26
RP3A: 12
RP3A: 12
RP3A: 22
RP3A: 24
RP3A: 22RP3A: 24
RP3A: 14
RP3A: 14
RP3A: 24
RP3A: 15
RP3A: 15
RP3A: 14RP3A: 15
RP3A: 12
RP3A: 12
RP3A: 21
RP3A: 20
RP3A: 22RP3A: 20
RP3A: 20
RP3A: 21
RP3A: 21
RP3A: 17
RP3A: 17
RP3A: 17
RP3B: 13
RP3A: 13RP3B: 18
RP3B: 18
RP3A: 13
RP3A: 23
RP3A: 23
RP3A: 23
RP3A: 13RP3B: 18
RP3B: 8
RP3B: 8
RP3B: 8
RP3B: 4
RP3B: 4
RP3B: 4
RP3B: 13
RP3B: 13
RP3B: 19
RP3B: 19
RP3B: 19
RP3B: 16
RP3B: 16
RP3B: 16
RP3B: 9
RP3B: 9
RP3B: 9
RP3B: 13
RP3B: 20
RP3B: 17
RP3B: 17
RP3B: 17
RP3B: 6
RP3B: 6
RP3B: 6
RP3B: 20
RP3B: 20
RP3B: 14
RP3B: 14
RP3B: 14
RP3B: 25
RP3B: 25
RP3B: 25
RP3B: 12
RP3B: 12
RP3B: 12
RP3B: 23
RP3B: 23
RP3B: 23
RP3B: 22
RP3B: 27
RP3B: 27
FCU
2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C
RP3B: 21
RP3A: 3
RP3B: 21
RP3A: 3
RP3B: 21
RP3B: 7
RP3B: 7
RP3B: 7
RP3B: 10
RP3A: 9
RP3A: 11
RP3A: 9
RP3A: 11RP3A: 11
RP3B: 5
RP3B: 5
MDP3: 18,20
MDP3: 14,16
RP3B: 10
RP3B: 10
RP3A: 26
MP3: 9
MP3: 9
MP3: 13,15,17 MP3: 12,14,16
2#12 & 12G, 3/4"C
MP3: 2
MP3: 2
MP3: 5MP3: 2
MP3: 8
MP3: 8MP3: 3MP3: 3
MP3: 7MP3: 6MP3: 4MP3: 4
+60
RP3B: 1
MP3: 10
MP3: 10
MP3: 10
MP3: 10
2#12 & 12G, 3/4"C
2#12 & 12G, 3/4"C
2#12 & 12G, 3/4"C 2#12 & 12G, 3/4"C
5 5
RP3B: 10
2#12 & 12G, 3/4"C
EWC
MP3: 1
(TYP)
4 4 4 44 44 4 44 44
RP3A: 2 RP3A: 2 RP3A: 8 RP3A: 8
C CCC
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
C
RP3A: 8
FCU
COPIER
RP3B: 3
TV
CUSB
RP3A: 9
+40
RP3A: 10
TYP. FOR
ALL ROOMS
TP3: 2C
RP3A: 11
REF
+48
REF
RP3B: 24
RP3B: 26
MICROWAVE
RP3A: 28
DESV
C
RP3A: 3
E-402
G3
TWO ALIGNED
OUTLETS (TV AT +60 &
ANOTHER AT 18")
+40
+40 +40
+40 +40
+40 +40
+40 +40
+40 +40
+40
+40
+40 +40
+40 +40
+40 +40
+40 +40
+40 +40
+40 +40
+40
+40
+40 +40
+40
DESV
+40
DH
x12Bx4
AF
AF
AF
AFAF
AF AF
AFAF
AF
AF
AF
AF
AF
AF
AF
(TYP. FOR ALL)
L15-50RL15-50RL15-50R
MP3: 18,20,22
3#6 & 10G, 1"C
KEYED NOTES SEAL
1. FOR GENERAL DEMOLITION NOTES, ABBREVIATIONS, FEEDER SCHEDULE, MOUNTING
HEIGHT GRAPH, AND DRAWING INDEX, REFER TO SHEET E-001. FOR GENERAL SYMBOLS
AND FEEDER ID SCHEDULE, REFER TO SHEETS E-002 AND E-003.
2. CIRCUIT OUTLETS FROM SAME FLOOR ELECTRICAL ROOM(S). BRANCH CIRCUIT (HOME
RUN) IDENTIFIED WITH BOUNDARY LINES AND CIRCUITED BY DISPLAYING BRANCH
PANEL NAME AND CIRCUIT NUMBER, UON.
3. THE MINIMUM AMPACITY OF THE OCPD FOR ALL POWER AND LIGHTING BRANCH
CIRCUITS BE 20A/1-POLE, 125V RATED DEVICE, UON. DUPLEX AND SINGLE
RECEPTACLES, 125V, 20-AMPERES, IN ANY AREAS, OTHER THAN ELECTRICAL,
MECHANICAL, & TELECOM ROOMS AND JANITORIAL CLOSETS, MUST USE TAMPERED
RESISTANT DUPLEX (OR QUADRUPLEX) RECEPTACLES.
4. GENERAL BRANCH WIRING CONNECTION TO GFI (GROUND FAULT INTERRUPTER)
OUTLETS TO THE LINE SIDE TERMINALS AND DAISY-CHAIN WIRE CONNECTIONS WITH
MECHANICAL WIRE SPLICER. NO GFI DEVICE CONNECTION ON THE LOAD SIDE
TERMINALS, OR FED-THROUGH TO OTHER DOWN-STREAM DUPLEX OUTLETS OR OTHER
GFI OUTLETS.
5. COORDINATE LOCATION AND HEIGHT OF OUTLETS AND DEVICES WITH CASEWORK,
FURNITURE, AND PARTITION ELEVATIONS. REFER TO ARCHITECTURAL AND INTERIOR
ELEVATIONS, DETAILS, AND MOUNTING INSTALLATION INFORMATION. NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES BEFORE INSTALLATION OF ANY
CONDUIT, OUTLET BOXES, AND/OR SUPPORTING HARDWARE.
6. THE MAXIMUM 600V RATED INSULATED CONDUCTOR RUN LENGTH, IN METALLIC CONDUIT,
FOR ALL POWER AND LIGHTING CIRCUITS FED WITH A 20A/1-POLE, 125V OR AT 208V FOR
20A/2-POLE, RATED CIRCUIT BREAKER DEVICE (CALCULATED AT 16 AMPERES MAX PER
CIRCUIT PER NEC), UON, LIMITED VOLTAGE DROP LESS THAN 3% ARE:
A. LESS THAN 60 FT - 2#12 AWG & 1#12G, IN 1/2" EMT.
B. MORE THAN 60 FEET, LESS THAN 100FT - 2#10 AWG & 1#10G, IN 1/2" EMT.
C. MORE THAN 100 FEET, LESS THAN 150FT - 2#8 AWG & 1#10G, IN 3/4" EMT.
D. MORE THAN 150 FEET, LESS THAN 250FT - 2#6 AWG & 1#10G, IN 3/4" EMT.
7. COORDINATE WITH MECHANICAL FOR LOCATION OF ALL HVAC CONTROL DEVICES,
MOTORIZED DAMPERS, OR CONTROL CABINETS TO PROVIDE CONTROL POWER IN LOCAL
JUNCTION BOX, ROUTING OF CONDUIT AND CONDUCTORS AS RATED FOR SHEET NOTE 6
ABOVE, UNLESS REQUIRED, PLENUM RATED CONDUCTORS FOR SPACES ABOVE
ACCESSIBLE SUSPENDED CEILINGS. PROVIDE 120V CIRCUIT FOR PLUMBING ELECTRONIC
TAP PRIMERS.
8. CADET ROOM BRANCH CIRCUITS MUST BE PROTECTED BY ARC-FAULT RECEPTACLES IN
ACCORDANCE WITH NEC 210.12 (A)(5). MARK THE FIRST OUTLET IN THE BRANCH CIRCUIT AS
THE FIRST OUTLET OF THE CIRCUIT.
9. RECESSED OUTLET BOXES MOUNTED IN SAME WALL FROM APPOSING SIDES TO BE
SEPARATED MINIMUM 6-INCH TO AVOID BACK-TO-BACK OUTLET BOX CONFLICTS.
10. EXTERIOR OUTLETS MUST BE CUT INTO GRANITE/MASONRY AND RACEWAY CONCEALED
WITHIN CONSTRUCTION.
SHEET NOTES
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PLAN NORTHPART APART B
KEY PLANKEY PLAN
PART APART B
E-103
LEE
T H
IR
D
F L O
O R
P O
W E
R P
L A
N
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J A
K
B E
B
M M
B
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"C1
POWER FLOOR PLAN - THIRD
LEVEL
1 COORDINATE MOUNTING HEIGHT WITH COUNTERTOP AND BACKSPLASH FOR GFI, TAMPER-RESISTANT, OUTLETS. CRCUIT AS SHOWN. TYPICAL
IN ALL REST/SHOWER ROOMS.
2 COORDINATE MOUNTING HEIGHT OF DEDICATED OUTLET WITH HVAC/HEATER/MAINTENANCE EQUIPMENT IN COORIDOR. CIRCUIT AS SHOWN.
TYPICAL THROUGHOUT CORRIDORS.
3 SINGLE RECEPTACLE OUTLET, MOUNTED AT HEIGHT INDICATED ON SYMBOL LEGEND (E-001). COORDINATE LOCATION WITH ARCHITECHAL
SHEETS WITH FIRE RATED WALLS. CIRCUIT AS SHOWN.
4 COORDINATE MOUNTING HEIGHT OF MOTOR-RATED DISCONNECT SWITCH (UNLESS OUTLET IS INDICATED) WITH HVAC EQUIPMENT AT CEILING.
CIRCUIT AS SHOWN. TYPICAL THROUGHOUT ALL FLOORS.
5 COORDINATE MOUNTING HEIGHT AND QUANTITY OF JUNCTION BOX FOR EACH HVAC MOTORIZED DAMPER IN SHAFT. CIRCUIT AS SHOWN.
TYPICAL THROUGHOUT EACH FLOOR.
6 PROVIDE 30A/3W/250V DRYER OUTLET. COORDINATE LOCATION WITH ARCHITECTUAL DRAWINGS. CIRCUIT AS SHOWN. TYPICAL IN LAUNDRY
AREA.
7 PROVIDE JUNCTION BOX FOR ELECTRIC WATER COOLER AND CIRCUIT TO 120V/20A GFI CIRCUIT BREAKER IN PANEL. COORDINATE LOCATION
WITH ARCHITECTUAL AND INTERIOR FURNITURE DRAWINGS.
8 COORDINATE MOUNTING HEIGHT WITH COUNTERTOP AND BACKSPLASH FOR GFI, TAMPER-RESISTANT, OUTLETS. CIRCUIT AS SHOWN. TYPICAL
IN ALL CADET ROOMS.
9 COORDINATE MOUNTING HEIGHT AND LOCATION OF JUNCTION BOX FOR SECURITY EQUIPMENT OR DEVICE WITH TELECOM/SECURITY
DRAWINGS.
10 COORDINATE LOCATION OF SUB-METERING WORKSTATION / DISPLAY PANEL WITH INTERIORS. SEE GENERAL NOTE 24, E-002 FOR
SUB-METERING REQUIREMENTS.
11 IN CADET ROOMS ONLY - OUTLETS IDENTIFIED WITH "AF" ARE CIRCUIT HOMERUNS. SEE PANELBOARD SCHEDULES FOR IDENTIFIED CIRCUITS
PROTECTED BY ARC FAULT CIRCUIT BREAKERS. CIRCUIT AS SHOWN.
IS
S U
E D
B Y
A M
E N
D M
E N
T
/1
/2
SM SM SM SM SM SM
SMSMSMSMSMSMSMSMSMSMSMSMSM
C C FECFEC
SM
SM
MD MD
MD
MDMD
JJ
J J J J J J
J J
J J
J
J J J J
J J
J
J xG x1 xL xH xJ xK x2 x3 x5 x6 x7 x8 x9 x14x10 x11 x12 x13 x11A x12A
+40
+40 +40
+40
USB USB
USB
+42 +42
USB
USB
USB
USB
AF
AF
USB
USB
USB
USB USB
USB
USB
USB
AF AF
USB
USB
USB
USB
USB
USB
AF AF
USB
USB USB
USB
USB
USB
USB
AF AF
USB
USB
USB USB
USB
USB
USB
USB
USB
USB
AFAF
USB
USB
USB
USB
USB USB
USB
USB
AFAF
USB
USB
USB
USB
USB
USB
USB
AFAF
USB
USB
USB
USB
AF
USB
USB
USB
USB
USB
USBUSB
USB
USBUSB
USB
USB
USB
USB
AF AF AF
USB
+40+40 +40
+40
RP4B: 22
+40
+40
+40 +40
+40 +40 +40
+40
USB
+42 +42
+40 +40
+40 +40
+40 +40
+40 +40
+40 +40
+40
+40
+40
USB
USB
+40
+40
+40+40
+40
+40
E-401
F1
DEDICATED FOR CORRIDOR
HEATER
CADET ROOM
L4007
WOMEN'S
ROOM
L402
STAIR 1
LS-4-1
CADET ROOM
L4001
STORAGE
L404
LAUNDRY
L403
CORRIDOR
L400
CADET ROOM
L4009
CADET ROOM
L4011
CADET ROOM
L4013
MEN'S ROOM
L408
TELECOM
L406
JANITOR
L407
STAIR 2
LS-4-2
ELEV.
LE-4-1
CADET ROOM
L4019
CORRIDOR
L400
CADET ROOM
L4018
CADET ROOM
L4017
CADET ROOM
L4016
CADET ROOM
L4015
CADET ROOM
L4014
CADET ROOM
L4012
CADET ROOM
L4008
CADET ROOM
L4010
CADET ROOM
L4005
CADET ROOM
L4006 CADET ROOM
L4004
CADET ROOM
L4003
CADET ROOM
L4002
ELECTRICAL
L401
DH
+40+40
CORRIDOR
+36
FCU
DH
FCU
+36
MDP4: 14,16
MDP4: 18,20RP4A: 3
RP4B: 7
USB
RP4B: 7 RP4B: 7 RP4B: 5
RP4B: 8
RP4B: 3 RP4B: 3
RP4B: 2
RP4B: 2
RP4B: 4
RP4B: 4
+20
RP4B: 2
RP4B: 8
RP4B: 8
RP4B: 26
RP4B: 26
+20+20+20+20+20+20+20+20+20+20+20+20+20
+20 +20
+20
USB
2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"C
USB USBUSB
+20
USB
RP4A: 4
RP4A: 4
RP4A: 4
RP4A: 7
RP4A: 7
RP4A: 7
MP4: 10
MP4: 10
RP4A: 3
3#6 & #10G, 1"C 3#6 & #12G, 1"C
RP4B: 7
RP4B: 8
RP4B: 17
RP4B: 19
RP4B: 19RP4B: 17
RP4B: 28
RP4B: 17 RP4B: 19
RP4B: 26+40 +40
RP4B: 4
RP4B: 28
RP4B: 28
2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"CMP4: 12,14,16 MP4: 13,15,17
RP4A: 14
RP4A: 14
RP4A: 14
USB
RP4A: 3
RP4A: 3
RP4A: 16RP4A: 17
RP4B: 18
RP4A: 9
RP4A: 9
RP4A: 9
USB
RP4A: 5
RP4A: 5
RP4A: 16
RP4A: 16
RP4A: 17
RP4A: 17
RP4A: 6
RP4A: 10
USBUSBUSBUSB
RP4A: 6 RP4A: 5RP4A: 19
RP4A: 10
RP4A: 19
RP4A: 19
RP4A: 6
RP4A: 13
RP4A: 13
RP4A: 13
RP4A: 15
RP4A: 15
RP4A: 10
RP4A: 10
RP4A: 12
RP4A: 21
RP4A: 21
RP4A: 21
RP4A: 15
RP4B: 1
RP4B: 18
RP4B: 18
RP4B: 1RP4B: 18
RP4A: 20
RP4B: 18
2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C
USBUSB USB USBUSB USB USB
2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"C
MP4: 9MP4: 9
MP4: 7MP4: 7MP4: 2
MP4: 3
MP4: 6MP4: 6
MP4: 5
MP4: 5
RP4A: 12
RP4A: 12
RP4A: 18
RP4A: 18
RP4A: 18RP4B: 9
RP4B: 9
RP4B: 9
RP4A: 11
RP4A: 8RP4B: 21
RP4B: 21
RP4A: 8
RP4A: 8
RP4B: 21
RP4A: 2
RP4A: 2
RP4A: 11
RP4A: 11
MP4: 8 MP4: 8
RP4B: 15 RP4B: 13 RP4B: 12 RP4B: 16 RP4B: 14
RP4B: 16
RP4B: 14
RP4A: 11
RP4B: 10
RP4B: 27
RP4B: 25
RP4B: 16
RP4B: 14
RP4B: 12
RP4B: 13
RP4B: 12RP4B: 13
RP4B: 27
RP4B: 24RP4B: 25RP4B: 27RP4B: 23RP4B: 20
RP4B: 22
RP4B: 10
RP4B: 10
RP4B: 15
RP4B: 15
RP4B: 23
RP4B: 23
RP4B: 20
RP4B: 20
RP4B: 24
RP4B: 25
RP4B: 11
RP4B: 11
RP4B: 11
+40
RP4B: 22
RP4B: 6RP4B: 6
RP4A: 20
RP4A: 20
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
MP4: 4MP4: 4
MP4: 4
MP4: 4
FCU
FCU
(TYP)
(TYP)
(TYP)
(TYP)
FCU
FCU
FCU
FCU
1 3
FCU
FCU
1FCU
FCU
FCU
1FCU
FCU
FCU
FCU
FCU
FCU
1 FCU
FCU
1 333333333333
2#12 & #12G, 3/4"C
EWC
MP4: 1
RP4B: 7
DESV
RP4B: 5
TP4: 2
TYP. FOR
ALL ROOMS
24" AFF 24" AFF
RP4B: 5 RP4B: 5
DH
E-402
G6
+40
+40
+20+20
+40
+40 +40
+40 +40
+40 +40
+40 +40 +40
+40
+40 +40
+40
+40
+40 +40
+40 +40
+40 +40
+40 +40
+40 +40
+40
+40
+40 +40
+40 +40
+40
+40
+40 x12Bx4
AF
AF
AF
AF
AF
AFAF
AF
AF
AF
AF
AF
AF
AF AF
AF
AF AF
AF
(TYP. FOR ALL)
L15-50R L15-50R L15-50R 3#6 & #10G, 1"C
MP4: 18,20,22
1. FOR GENERAL DEMOLITION NOTES, ABBREVIATIONS, FEEDER SCHEDULE, MOUNTING
HEIGHT GRAPH, AND DRAWING INDEX, REFER TO SHEET E-001. FOR GENERAL SYMBOLS
AND FEEDER ID SCHEDULE, REFER TO SHEETS E-002 AND E-003.
2. CIRCUIT OUTLETS FROM SAME FLOOR ELECTRICAL ROOM(S). BRANCH CIRCUIT (HOME
RUN) IDENTIFIED WITH BOUNDARY LINES AND CIRCUITED BY DISPLAYING BRANCH
PANEL NAME AND CIRCUIT NUMBER, UON.
3. THE MINIMUM AMPACITY OF THE OCPD FOR ALL POWER AND LIGHTING BRANCH
CIRCUITS BE 20A/1-POLE, 125V RATED DEVICE, UON. DUPLEX AND SINGLE
RECEPTACLES, 125V, 20-AMPERES, IN ANY AREAS, OTHER THAN ELECTRICAL,
MECHANICAL, & TELECOM ROOMS AND JANITORIAL CLOSETS, MUST USE TAMPERED
RESISTANT DUPLEX (OR QUADRUPLEX) RECEPTACLES.
4. GENERAL BRANCH WIRING CONNECTION TO GFI (GROUND FAULT INTERRUPTER)
OUTLETS TO THE LINE SIDE TERMINALS AND DAISY-CHAIN WIRE CONNECTIONS WITH
MECHANICAL WIRE SPLICER. NO GFI DEVICE CONNECTION ON THE LOAD SIDE
TERMINALS, OR FED-THROUGH TO OTHER DOWN-STREAM DUPLEX OUTLETS OR OTHER
GFI OUTLETS.
5. COORDINATE LOCATION AND HEIGHT OF OUTLETS AND DEVICES WITH CASEWORK,
FURNITURE, AND PARTITION ELEVATIONS. REFER TO ARCHITECTURAL AND INTERIOR
ELEVATIONS, DETAILS, AND MOUNTING INSTALLATION INFORMATION. NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES BEFORE INSTALLATION OF ANY
CONDUIT, OUTLET BOXES, AND/OR SUPPORTING HARDWARE.
6. THE MAXIMUM 600V RATED INSULATED CONDUCTOR RUN LENGTH, IN METALLIC CONDUIT,
FOR ALL POWER AND LIGHTING CIRCUITS FED WITH A 20A/1-POLE, 125V OR AT 208V FOR
20A/2-POLE, RATED CIRCUIT BREAKER DEVICE (CALCULATED AT 16 AMPERES MAX PER
CIRCUIT PER NEC), UON, LIMITED VOLTAGE DROP LESS THAN 3% ARE:
A. LESS THAN 60 FT - 2#12 AWG & 1#12G, IN 1/2" EMT.
B. MORE THAN 60 FEET, LESS THAN 100FT - 2#10 AWG & 1#10G, IN 1/2" EMT.
C. MORE THAN 100 FEET, LESS THAN 150FT - 2#8 AWG & 1#10G, IN 3/4" EMT.
D. MORE THAN 150 FEET, LESS THAN 250FT - 2#6 AWG & 1#10G, IN 3/4" EMT.
7. COORDINATE WITH MECHANICAL FOR LOCATION OF ALL HVAC CONTROL DEVICES,
MOTORIZED DAMPERS, OR CONTROL CABINETS TO PROVIDE CONTROL POWER IN LOCAL
JUNCTION BOX, ROUTING OF CONDUIT AND CONDUCTORS AS RATED FOR SHEET NOTE 6
ABOVE, UNLESS REQUIRED, PLENUM RATED CONDUCTORS FOR SPACES ABOVE
ACCESSIBLE SUSPENDED CEILINGS. PROVIDE 120V CIRCUIT FOR PLUMBING ELECTRONIC
TAP PRIMERS.
8. CADET ROOM BRANCH CIRCUITS MUST BE PROTECTED BY ARC-FAULT RECEPTACLES IN
ACCORDANCE WITH NEC 210.12 (A)(5). MARK THE FIRST OUTLET IN THE BRANCH CIRCUIT AS
THE FIRST OUTLET OF THE CIRCUIT.
9. RECESSED OUTLET BOXES MOUNTED IN SAME WALL FROM APPOSING SIDES TO BE
SEPARATED MINIMUM 6-INCH TO AVOID BACK-TO-BACK OUTLET BOX CONFLICTS.
10. EXTERIOR OUTLETS MUST BE CUT INTO GRANITE/MASONRY AND RACEWAY CONCEALED
WITHIN CONSTRUCTION.
SHEET NOTES KEYED NOTES SEAL
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PLAN NORTHPART APART B
KEY PLANKEY PLAN
PART APART B
E-104
LEE
F O
U R
T H
F L O
O R
P O
W E
R P
L A
N
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J A
K
B E
B
M M
B
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"C1
POWER FLOOR PLAN - FOURTH
LEVEL
1 COORDINATE MOUNTING HEIGHT OF DEDICATED OUTLET WITH HVAC/HEATER/MAINTENANCE EQUIPMENT IN COORIDOR. CIRCUIT AS SHOWN.
TYPICAL THROUGHOUT CORRIDORS.
2 SINGLE RECEPTACLE OUTLET, MOUNTED AT HEIGHT INDICATED ON SYMBOL LEGEND (E-001). COORDINATE LOCATION WITH ARCHITECHAL
SHEETS WITH FIRE RATED WALLS. CIRCUIT AS SHOWN.
3 COORDINATE MOUNTING HEIGHT OF MOTOR-RATED DISCONNECT SWITCH (UNLESS OUTLET IS INDICATED) WITH HVAC EQUIPMENT AT CEILING.
CIRCUIT AS SHOWN. TYPICAL THROUGHOUT ALL FLOORS.
4 COORDINATE MOUNTING HEIGHT AND QUANTITY OF JUNCTION BOX FOR EACH HVAC MOTORIZED DAMPER IN SHAFT. CIRCUIT AS SHOWN.
TYPICAL THROUGHOUT EACH FLOOR.
5 PROVIDE 30A/3W/250V DRYER OUTLET. COORDINATE LOCATION WITH ARCHITECTUAL DRAWINGS. CIRCUIT AS SHOWN. TYPICAL IN LAUNDRY
AREA.
6 PROVIDE JUNCTION BOX FOR ELECTRIC WATER COOLER AND CIRCUIT TO 120V/20A GFI CIRCUIT BREAKER IN PANEL. COORDINATE LOCATION
WITH ARCHITECTUAL AND INTERIOR FURNITURE DRAWINGS.
7 COORDINATE MOUNTING HEIGHT WITH COUNTERTOP AND BACKSPLASH FOR GFI, TAMPER-RESISTANT, OUTLETS. CIRCUIT AS SHOWN. TYPICAL
IN ALL CADET ROOMS.
8 COORDINATE MOUNTING HEIGHT AND LOCATION OF JUNCTION BOX FOR SECURITY EQUIPMENT OR DEVICE WITH TELECOM/SECURITY
DRAWINGS.
9 IN CADET ROOMS ONLY - OUTLETS IDENTIFIED WITH "AF" ARE CIRCUIT HOMERUNS. SEE PANELBOARD SCHEDULES FOR IDENTIFIED CIRCUITS
PROTECTED BY ARC FAULT CIRCUIT BREAKERS. CIRCUIT AS SHOWN.
IS
S U
E D
B Y
A M
E N
D M
E N
T
/1
/2
SM
SM SM
SM
S
M SM
SMSMSM
SMSMSM
SMSMSMSMSM
SM
SM
C C FECFEC
SM
SM
MD
MDMD
MD
MD
JJ
J J J J J
J
J J
J J
J J J J J J
JJ
J xG x1 xL xH xJ xK x2 x3 x5 x6 x7 x8 x9 x14x10 x11 x12 x13 x11A x12A
RP5B: 17
RP5B: 15
RP5B: 15
R P
A
RP5A: 10
USB
USB
USB
+42
RP5B: 17
ELEC.
L501
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
USB
AF AF AFAF
AF AF AF AF AF AF AF
AF
+40
+40 +40
+40+40
RP5B: 2RP5B: 4
+40
+40
+40
+40
+40
+40
+40+40
+40+40
+40+40
+40+40
+40
+40
+40+40
+40+40
+40+40
+40
+40+40
+40+40
+40+40
+40
AF
AF
AF
AF AF AF
RP5A: 10
RP5A: 10
E-401
C4
DEDICATED FOR CORRIDOR
HEATER
CADET ROOM
L5001
WOMEN'S
ROOM
L502
STAIR 1
LS-5-1
CORRIDOR
L500
LAUNDRY
L503
STORAGE
L504
CADET ROOM
L5007
CADET ROOM
L5009
CADET ROOM
L5011
CORRIDOR
L500
CADET ROOM
L5002
CADET ROOM
L5003
CADET ROOM
L5004
CADET ROOM
L5005
CADET ROOM
L5006
CADET ROOM
L5008
CADET ROOM
L5010
CADET ROOM
L5012
CADET ROOM
L5014
CADET ROOM
L5015
CADET ROOM
L5016
CADET ROOM
L5017
CADET ROOM
L5018
CORRIDOR
L500
CADET ROOM
L5019
ELEV.
LE-5-1
STAIR 2
LS-5-2 JANITOR
L507
TELECOM
L506
MEN'S ROOM
L508
CADET ROOM
L5013
+36
+48
MDP5: 18,20
CORRIDOR
L500b
+36
L15-50R
RP5A: 6
RP5B: 1
RP5B: 1
RP5A: 6
L15-50R
MDP5: 14,16
RP5A: 6
RP5A: 6
RP5A: 6
RP5A: 6
RP5A: 15 RP5A: 15
RP5A: 15
RP5A: 12
RP5B: 3
RP5B: 3
RP5B: 2
RP5A: 1
RP5B: 12
RP5B: 12
RP5B: 3
RP5B: 20RP5B: 19
+40
RP5B: 4
RP5B: 2
+40
RP5B: 4
RP5B: 20
RP5B: 20
RP5B: 19
RP5B: 6
RP5B: 6
RP5B: 6
RP5B: 17
RP5B: 17
+42
USB
RP5A: 12
RP5A: 3RP5A: 7
RP5A: 7
+40 RP5A: 3
3#6 & #10G, 1"C 3#6 & #10G, 1"C
MP5: 13,15,17MP5: 10,12,14
USBUSBUSB +20
+20+20+20
USB
RP5B: 19
RP5B: 27
RP5B: 27
RP5B: 13
RP5B: 13
RP5B: 13
+RP5A: 19RP5A: 16
RP5A: 19
RP5A: 16
RP5A: 9
RP5A: 8
RP5A: 8RP5A: 9
+20+20
RP5A: 19
RP5A: 4
RP5A: 4
RP5A: 4
RP5A: 17
RP5A: 10
RP5A: 11
RP5A: 8RP5A: 9RP5A: 5
MP5: 6
RP5A: 20
USBUSBUSBUSB
+20+20
RP5A: 3
RP5A: 16
RP5A: 13 RP5A: 14
RP5A: 14
RP5A: 17RP5A: 14
RP5A: 21
RP5A: 18 RP5A: 20
RP5A: 5
RP5A: 11
RP5A: 11RP5A: 11
RP5A: 20
USBUSBUSBUSBUSBUSBUSBUSB
+20+20+20+20 +20+20+20+20+20
USB
RP5A: 21RP5A: 18
RP5A: 21RP5A: 18
RP5A: 13
RP5A: 13
RP5B: 5RP5B: 24
RP5B: 24
RP5B: 5
RP5B: 5RP5B: 24
RP5B: 8
RP5B: 8
RP5B: 9
RP5B: 11 RP5B: 9
RP5B: 9 RP5B: 7
USB
RP5A: 17
RP5B: 7
RP5B: 7
RP5B: 21RP5B: 23
RP5B: 8
+RP5B: 14RP5B: 16
RP5B: 14
RP5B: 16
RP5B: 28
RP5B: 26
RP5B: 23 RP5B: 21
RP5B: 21
RP5B: 23
RP5B: 11
RP5B: 8
RP5B: 11RP5B: 26RP5B: 28RP5B: 30RP5B: 25
RP5B: 26RP5B: 28
RP5B: 14RP5B: 16
RP5B: 30
RP5B: 25
RP5B: 18
RP5B: 18
RP5B: 10
RP5B: 10
RP5B: 18
RP5B: 25 RP5B: 30
2#12 & #12G, 3/4"C
FCU
MP5: 9
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"C 2#12 & #12G, 3/4"C
MP5: 6MP5: 4MP5: 4MP5: 8MP5: 7MP5: 7
MP5: 3
MP5: 3MP5: 5
MP5: 5
DH
DH
MP5: 9
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
2#12 & #12G, 3/4"C
MP5: 2
MP5: 2
MP5: 2MP5: 2
(TYP)
(TYP)
(TYP)
(TYP)
4444444444444
4 4
EWC
2#12 & #12G, 3/4"C
MP5: 1
(TYP)
FCU
FCU
FCU
1FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
MP5: 8
TYP. FOR
ALL ROOMS
HHWP
TP5: 1
SBB
RP5B: 29 RP5B: 29 RP5B: 29 RP5B: 29
24" AFF +40 +40 24" AFF
RP5B: 29
24" AFF
+40 24" AFF
RP5B: 12
RP5B: 12
RP5B: 12
RP5B: 12
24" AFF
RP5B: 12
+20
USB
RP5A: 7
+20
RP5B: 27
USB
DESV
FCU
VFD
HPRAR:
13,15,17
E-402
G8
+40
+40 +40 +40
+40 +40
+40
+40 +40
+40
+20
+40
+40 +40
+40 +40
+40 +40
+40+40
+40 +40
+40
+40
+40 +40
+40 +40
+40 +40
+40
+40 +40
+40 +40
+40 x12Bx4
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF
AF AF
AF
AF
AF
AF
AF
AF
(TYP. FOR ALL)
L15-50R
MP5: 16,18,20
3#6 & #10G, 1"C
KEYED NOTES SEAL
1. FOR GENERAL DEMOLITION NOTES, ABBREVIATIONS, FEEDER SCHEDULE, MOUNTING
HEIGHT GRAPH, AND DRAWING INDEX, REFER TO SHEET E-001. FOR GENERAL SYMBOLS
AND FEEDER ID SCHEDULE, REFER TO SHEETS E-002 AND E-003.
2. CIRCUIT OUTLETS FROM SAME FLOOR ELECTRICAL ROOM(S). BRANCH CIRCUIT (HOME
RUN) IDENTIFIED WITH BOUNDARY LINES AND CIRCUITED BY DISPLAYING BRANCH
PANEL NAME AND CIRCUIT NUMBER, UON.
3. THE MINIMUM AMPACITY OF THE OCPD FOR ALL POWER AND LIGHTING BRANCH
CIRCUITS BE 20A/1-POLE, 125V RATED DEVICE, UON. DUPLEX AND SINGLE
RECEPTACLES, 125V, 20-AMPERES, IN ANY AREAS, OTHER THAN ELECTRICAL,
MECHANICAL, & TELECOM ROOMS AND JANITORIAL CLOSETS, MUST USE TAMPERED
RESISTANT DUPLEX (OR QUADRUPLEX) RECEPTACLES.
4. GENERAL BRANCH WIRING CONNECTION TO GFI (GROUND FAULT INTERRUPTER)
OUTLETS TO THE LINE SIDE TERMINALS AND DAISY-CHAIN WIRE CONNECTIONS WITH
MECHANICAL WIRE SPLICER. NO GFI DEVICE CONNECTION ON THE LOAD SIDE
TERMINALS, OR FED-THROUGH TO OTHER DOWN-STREAM DUPLEX OUTLETS OR OTHER
GFI OUTLETS.
5. COORDINATE LOCATION AND HEIGHT OF OUTLETS AND DEVICES WITH CASEWORK,
FURNITURE, AND PARTITION ELEVATIONS. REFER TO ARCHITECTURAL AND INTERIOR
ELEVATIONS, DETAILS, AND MOUNTING INSTALLATION INFORMATION. NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES BEFORE INSTALLATION OF ANY
CONDUIT, OUTLET BOXES, AND/OR SUPPORTING HARDWARE.
6. THE MAXIMUM 600V RATED INSULATED CONDUCTOR RUN LENGTH, IN METALLIC CONDUIT,
FOR ALL POWER AND LIGHTING CIRCUITS FED WITH A 20A/1-POLE, 125V OR AT 208V FOR
20A/2-POLE, RATED CIRCUIT BREAKER DEVICE (CALCULATED AT 16 AMPERES MAX PER
CIRCUIT PER NEC), UON, LIMITED VOLTAGE DROP LESS THAN 3% ARE:
A. LESS THAN 60 FT - 2#12 AWG & 1#12G, IN 1/2" EMT.
B. MORE THAN 60 FEET, LESS THAN 100FT - 2#10 AWG & 1#10G, IN 1/2" EMT.
C. MORE THAN 100 FEET, LESS THAN 150FT - 2#8 AWG & 1#10G, IN 3/4" EMT.
D. MORE THAN 150 FEET, LESS THAN 250FT - 2#6 AWG & 1#10G, IN 3/4" EMT.
7. COORDINATE WITH MECHANICAL FOR LOCATION OF ALL HVAC CONTROL DEVICES,
MOTORIZED DAMPERS, OR CONTROL CABINETS TO PROVIDE CONTROL POWER IN LOCAL
JUNCTION BOX, ROUTING OF CONDUIT AND CONDUCTORS AS RATED FOR SHEET NOTE 6
ABOVE, UNLESS REQUIRED, PLENUM RATED CONDUCTORS FOR SPACES ABOVE
ACCESSIBLE SUSPENDED CEILINGS. PROVIDE 120V CIRCUIT FOR PLUMBING ELECTRONIC
TAP PRIMERS.
8. CADET ROOM BRANCH CIRCUITS MUST BE PROTECTED BY ARC-FAULT RECEPTACLES IN
ACCORDANCE WITH NEC 210.12 (A)(5). MARK THE FIRST OUTLET IN THE BRANCH CIRCUIT AS
THE FIRST OUTLET OF THE CIRCUIT.
9. RECESSED OUTLET BOXES MOUNTED IN SAME WALL FROM APPOSING SIDES TO BE
SEPARATED MINIMUM 6-INCH TO AVOID BACK-TO-BACK OUTLET BOX CONFLICTS.
10. EXTERIOR OUTLETS MUST BE CUT INTO GRANITE/MASONRY AND RACEWAY CONCEALED
WITHIN CONSTRUCTION.
SHEET NOTES
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PLAN NORTHPART APART B
KEY PLANKEY PLAN
PART APART B
E-105
LEE
F
IF
T H
F L O
O R
P O
W E
R P
L A
N
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J A
K
B E
B
M M
B
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"C1
POWER FLOOR PLAN - FIFTH
LEVEL
1 COORDINATE MOUNTING HEIGHT WITH COUNTERTOP AND BACKSPLASH FOR GFI, TAMPER-RESISTANT, OUTLETS. CIRCUIT AS SHOWN. TYPICAL
IN ALL CADET ROOMS.
2 SINGLE RECEPTACLE OUTLET, MOUNTED AT HEIGHT INDICATED ON SYMBOL LEGEND (E-001). COORDINATE LOCATION WITH ARCHITECHAL
SHEETS WITH FIRE RATED WALLS. CIRCUIT AS SHOWN.
3 COORDINATE MOUNTING HEIGHT OF DEDICATED OUTLET WITH HVAC/HEATER/MAINTENANCE EQUIPMENT IN COORIDOR. CIRCUIT AS SHOWN.
TYPICAL THROUGHOUT CORRIDORS.
4 COORDINATE MOUNTING HEIGHT OF MOTOR-RATED DISCONNECT SWITCH (UNLESS OUTLET IS INDICATED) WITH HVAC EQUIPMENT AT
CEILING. CIRCUIT AS SHOWN. TYPICAL THROUGHOUT ALL FLOORS.
5 COORDINATE MOUNTING HEIGHT AND QUANTITY OF JUNCTION BOX FOR EACH HVAC MOTORIZED DAMPER IN SHAFT. CIRCUIT AS SHOWN.
TYPICAL THROUGHOUT EACH FLOOR.
6 PROVIDE 30A/3W/250V DRYER OUTLET. COORDINATE LOCATION WITH ARCHITECTUAL DRAWINGS. CIRCUIT AS SHOWN. TYPICAL IN LAUNDRY
AREA.
7 PROVIDE JUNCTION BOX FOR ELECTRIC WATER COOLER AND CIRCUIT TO 120V/20A GFI CIRCUIT BREAKER IN PANEL. COORDINATE LOCATION
WITH ARCHITECTUAL AND INTERIOR FURNITURE DRAWINGS.
8 COORDINATE MOUNTING HEIGHT AND LOCATION OF JUNCTION BOX FOR SECURITY EQUIPMENT OR DEVICE WITH TELECOM/SECURITY
DRAWINGS.
9 IN CADET ROOMS ONLY - OUTLETS IDENTIFIED WITH "AF" ARE CIRCUIT HOMERUNS. SEE PANELBOARD SCHEDULES FOR IDENTIFIED CIRCUITS
PROTECTED BY ARC FAULT CIRCUIT BREAKERS. CIRCUIT AS SHOWN.
IS
S U
E D
B Y
A M
E N
D M
E N
T
/1
/2
MDP3 400A - 208Y/120V, 3PH, 4W
LP3 RP3A RP3B MP3
LGT POWER POWER MECH
TP3
TELECOM
SPD
4W100 4W150 4W150 4W150 5W100 4W30
1 2 3 4 5
INV3
INVERTER
3W175
5W400T
2W20
T3
112.5kVA
480 - 208Y/120V
3PH, 4W
225AF
175AT
DS-T3
LSI
3P
RM 326
LSI
400AF
400AT
3P
100AF
100AT
3P
225AF
150AT
3P
225AF
150AT
3P
225AF
150AT
3P
100AF
100AT
3P
100AF
30AT
3P
F7
E-611
S P
A R
E 1M
M 1M 1M
M
RECEPTACLE LOADS
S E
E P
A N
E L B
O A
R D
S C
H E
D U
L E
F O
R
E
M A
IN
IN
G C
IR
C
U
IT
S O
N E
-8
200% NEUTRAL BUS
BAR CAPACITY
100AF
30AT
2P
6(A)
DRYER
3W30
100AF
30AT
2P
6(B)
DRYER
3W30
100AF
30AT
2P
100AF
50AT
3P
100AF
50AT
3P
S P
A R
E
S P
A R
E
MDP4 400A - 208Y/120V, 3PH, 4W
LP4 RP4 A RP4 B MP4
LGT POWER POWER MECH
TP4
TELECOM
4W100 4W150 4W150 4W150 5W100
1 2 3 4 5
INV4
INVERTER
3W175
5W400T
2W20
T4
112.5kVA
480 - 208Y/120V
3PH, 4W
225AF
175AT
DS-T4
LSI
3P
RM 426
LSI
400AF
400AT
3P
100AF
100AT
3P
225AF
150AT
3P
225AF
150AT
3P
225AF
150AT
3P
100AF
100AT
3P
A1
E-611
1M
M 1M 1M
S E
E P
A N
E L B
O A
R D
S C
H E
D U
L E
F
M A
IN
IN
G C
IR
C
U
IT
S O
N E
-8
200% NEUTRAL BUS
BAR CAPACITY
SPD
4W30
100AF
30AT
3P
S P
A R
E
M
RECEPTACLE LOADS
100AF
30AT
2P
6(A)
DRYER
3W30
100AF
30AT
2P
6(B)
DRYER
3W30
100AF
30AT
2P
100AF
50AT
3P
100AF
50AT
3P
S P
A R
E
S P
A R
E
F1
E-611
MDP2 400A - 208Y/120V, 3PH, 4W
LP2 RP2A RP2 B MP2
LGT POWER POWER MECH
TP2
TELECOM
SPD
4W100 4W150 4W150 4W150 5W100T 4W30
1 2 3 4 5 6
INV2
INVERTER
3W175
5W400T
2W20
T2
112.5kVA
480 - 208Y/120V
3PH, 4W
225AF
175AT
DS-T2
LSI
3P
RM 226
LSI
400AF
400AT
3P
100AF
100AT
3P
225AF
150AT
3P
225AF
150AT
3P
225AF
150AT
3P
100AF
100AT
3P
100AF
30AT
3P
100AF
30AT
SPARE
3P
1M
M 1M 1M
S E
E P
A N
E L B
O A
R D
S C
H E
D U
L E
F
M A
IN
IN
G C
IR
C
U
IT
S O
N E
-8
200% NEUTRAL BUS
BAR CAPACITY
100AF
30AT
SPARE
3P
100AF
50AT
SPARE
3P
100AF
50AT
SPARE
3P
MDP5 400A - 208Y/120V, 3PH, 4W
LP5 RP5
A
RP5
B
MP5
LGT POWER POWER MECH
TP5
TELECOM
4W100 4W150 4W150 4W150 5W100
1 2 3 4 5
INV5
INVERTER
3W175
5W400T
2W20
T5
112.5kVA
480 - 208Y/120V
3PH, 4W
225AF
175AT
DS-T5
LSI
3P
RM 526
LSI
400AF
400AT
3P
100AF
100AT
3P
225AF
150AT
3P
225AF
150AT
3P
225AF
150AT
3P
100AF
100AT
3P
A7
E-611
1M
M 1M 1M
S E
E P
A N
E L B
O A
R D
S C
H E
D U
L E
F
M A
IN
IN
G C
IR
C
U
IT
S O
N E
-8
200% NEUTRAL BUS
BAR CAPACITY
SPD
4W30
100AF
30AT
3P
S P
A R
E
M
RECEPTACLE LOADS
100AF
30AT
2P
6(A)
DRYER
3W30
100AF
30AT
2P
6(B)
DRYER
3W30
100AF
30AT
2P
100AF
50AT
3P
100AF
50AT
3P
S P
A R
E
S P
A R
E
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
E-611
LEE
E L E
C T
R
IC
A L R
O O
M P
O W
E R
R
IS
E R
D
IA
G R
A M
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J A
K
B E
B
M M
B
J
U L Y
W D
S D
RTA SUBMISSION
C B
U P
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"E-611
F7 THIRD FLOOR ONE LINE DIAGRAM
1/8" = 1'-0"E-611
A1 FOURTH FLOOR ONE LINE DIAGRAM
1/8" = 1'-0"E-611
F1 SECOND FLOOR ONE LINE DIAGRAM
1. REFER TO SHEET E-001 GENERAL NOTES, ONE
LINE DIAGRAM SYMBOLS, AND FEEDER ID
SCHEDULE.
2. FOR TRANSFORMER'S PRIMARY & SECONDARY
CONDUIT SIZES, PHASE & NEUTRAL
CONDUCTORS, & GROUND/BONDING SIZES,
REFER TO LOW-VOLTAGE INDOOR DRY-TYPE
TRANSFORMER SCHEDULE ON SHEET E-601.
SHEET NOTES:
1/8" = 1'-0"E-611
A7 FIFTH FLOOR ONE LINE DIAGRAM
1. PROVIDE A C/T AND CONNECT TO NETWORKED ELECTRIC
SUBMETERING/MONITORING ENERGY PANEL WORKSTATION
IN COLLABORATION ROOMS. ENERGY MONITORING AND
DISPLAY SYSTEM SHALL BE PROVIDED IN COLLABORATION
ROOMS. THE SYSTEM SHALL INDIVIDUALLY MONITOR:
A. TOTAL ENERGY (MAIN SERVICE SHARK 200 METERS),
B. HVAC,
C. INTERIOR AND EXTERIOR LIGHTING AND,
D. RECEPTACLE LOADS ON A FLOOR-BY-FLOOR BASIS.
LOADS SHALL BE DISPLAYED ON MONITORS LOCATED IN
COLLABORATION ROOMS. THE MONITORING SYSTEM
SHALL BE CONNECTED TO THE DPW BASE-WIDE
CONTROL SYSTEM VIA THE BAS SYSTEM.
E. REFER TO SPEC SECTION 26 09 13 POWER MONITOR
SYSTEM FOR DETAILS. COORDINATE WITH BASE
FACILITY DPW.
KEYED NOTES:
SEAL
IS
S U
E D
B Y
A M
E N
D M
E N
T
/2
/2
IS
S U
E D
B Y
A M
E N
D M
E N
T
/1
/2
| Sheets |
| Lee Barracks - E-102 |
| Lee Barracks - E-103 - Elect Amemdment_20210914 |
| Lee Barracks - E-104 - Elect Amemdment_20210914 |
| Lee Barracks - E-105 - Elect Amemdment_20210914 |
| Lee Barracks - E-611 - Elect Amemdment_20210914 |
File details come from the government source that posted it. Updated .