RTA Drawings Lee Vol 1_Part2.pdf

PDF 29 MB Posted

Attached to
Building 740, Lee Barracks and Building 738, Sherman Barracks Repair
Solicitation number
W912DS21B0004
Issued by

About this file

This document outlines a federal contract opportunity for building repair work at the United States Military Academy. The U.S. Army Corps of Engineers, New York District intends to issue a solicitation to award a firm-fixed price contract to repair Building 740 at Lee Barracks and Building 738 at Sherman Barracks at the United States Military Academy in West Point, New York. The repairs to Building 740 will fully renovate the facility and supporting site work, upgrading building systems, interiors, and adding a Cadet Health Clinic. Optional work includes fully renovating Building 738 and supporting site work. The period of performance is approximately 1,034 calendar days from notice to proceed. The estimated value of the construction is between $100 million and $200 million. The solicitation is anticipated to be posted on August 6, 2021 on SAM.gov with proposals due approximately 30 days later.

View the file

Other files

File Type Posted
Bid Abstract.pdf PDF
W912DS21B0004 Amendment 11.pdf PDF
Lee Barracks Electrical Drawings for Amendment.pdf PDF
Amendment 0010.pdf PDF
Amendment 0009.pdf PDF
Amendment 0008_Combined Drawings Final 9-10-21.pdf PDF
Amendment 0008_Combined Specifications 9-10-21.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007_LEE-SHERMAN SPECS rev.pdf PDF
Amendment 0007_Lee Sherman Section 01 32 00 Scheduling.pdf PDF
Amendment 0007_Dwgs_Sherman Barracks.pdf PDF
Amendment 0007_Building 740 Lee Barracks Site Walk through Sign in Sheet.pdf PDF
Amendment 0007.pdf PDF
Amendment 0007_Dwgs_Lee Barracks.pdf PDF
Amendment 0007_Sherman Barracks GER.pdf PDF
Amendment 0007_5.4 GER_West Point Lee Barracks signed.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0004_STEAM VAULT AMENDMENT DRAWINGS SHERMAN.pdf PDF
Amendment 0004_STEAM VAULT AMENDMENT DRAWINGS LEE.pdf PDF
Amendment 0004_Photos_Steam Vault F-4.pdf PDF
Amendment 0004_Photos_Steam Vault F-8.pdf PDF
Amendment 0004_WP Lee and Sherman Steam Vault Amendment SPECIFICATIONS 17 AUG 2021.pdf PDF
Amendment 0004_Photos_Steam Vault F-3.pdf PDF
Amendment 0003_RTA Drawings Lee Vol 1_Part3.pdf PDF
Amendment 0003_RTA Drawings Lee Vol 1_Part1.pdf PDF
Amendment 0003_RTA Drawings Lee Vol 1_Part2.pdf PDF
Amendment 0003_RTA Drawings Lee Vol 1_Part4.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
RTA Drawings Lee Vol 2.pdf PDF
RTA Drawings Lee Vol 3.pdf PDF
RTA Drawings Lee Vol 1_Part3.pdf PDF
RTA Drawings Lee Vol 1_Part1.pdf PDF
RTA Drawings Sherman Vol 2_Part2.pdf PDF
RTA Drawings Sherman Vol 2_Part1.pdf PDF
RTA Drawings Sherman Vol 1_Part2.pdf PDF
RTA Drawings Sherman Vol 1_Part1.pdf PDF
VOL 3 WP Lee and Sherman RTA Specs 23 JULY 2021.pdf PDF
VOL 2 WP Lee and Sherman RTA Specs 23 JULY 2021.pdf PDF
W912DS-21-B-0004_Solicitation.pdf PDF
VOL 4 WP Lee and Sherman RTA Specs 23 JULY 2021.pdf PDF
VOL 1 WP Lee and Sherman RTA Specs 23 JULY 2021.pdf PDF
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FLOOR DRAIN WITH

WEEPS

AND MEMBRANE CLAMPS

EXIST. CONC. SLAB, WIDEN

OPENING AS REQ. FOR

INSTALLATION OF NEW

FLOOR DRAIN

INFILL VOID WITH MORTAR

WATERPROOFING

MEMBRANE

FLOOR TILE ON THIN

SET

EPOXY GROUT

TAPERED MORTAR BED

(SLOPE TO DRAIN)

3 5/8" MET STUD

WATERPROOFING

MEMBRANE

FLEXIBLE SEALANT

TERRAZZO SHOWER BASE

CMU PARTITION, SEE PLANS

X X X X X X X

FLOOR TILE ON THIN SET

EPOXY GROUT, TYP.

TAPERED MORTAR BED

(SLOPE TO DRAIN)

WATER PROOFING

MEMBRANE

FLEXIBLE SEALANT

AGAINST TERRAZZO PAN

INTEGRAL DRAIN WITH

REMOVABLE GRID STRAINER

EXISTING FLOOR SLAB

M

IN

FILL VOID WITH MORTAR

1/2" CEMENT BACKER BD.

1/2" CORIAN PANEL, TYP.

MORTAR SETTING BED

FOR BASE

SEE PLANS FOR FLOOR DRAIN LOCATIONS

REINFORCED 1 1/2"

STRUCTURAL CONC.

INFILL, TYP.

X X XX X X X X X X X X X XXXXXXXXX XXXXX XXXX X

1' - 8" 1' - 8"

40" x 40" SQUARE TOPPING SLAB TAPPERED (1/8" SLOPE) TO DRAIN

PLUMBING IN CHASE

CORIAN PANEL EDGE

BEYOND

PARTITION BEYOND

SHOWER STALL LOCKER ROOMCORRIDOR

XXX

3 5/8" MET STUD

WATERPROOFING

MEMBRANE

FLEXIBLE SEALANT

TERRAZZO SHOWER BASE

X X X

INTEGRAL DRAIN WITH

REMOVABLE GRID STRAINER

M

IN

FILL VOID WITH

MORTAR

1/2" CEMENT BACKER BD.

1/2" CORIAN PANEL, TYP.

MORTAR SETTING BED

FOR BASE

X X X X X XXX XXXXX

SHOWER STALL

XXX XX XXXX

SHOWER STALL SHOWER STALL

XX

EQ EQ

XX X X X X X

F O

T

TILE AS SCHEDULED

MORTAR

5/8" BACKER BOARD

3 5/8" CFMF

1/2" BACKER BOARD

1/2" SOLID

SURFACE AS

SCHEDULED

SHOWER CURTAIN

ROD ABV

F O

S

S H

O W

E R

D E

P T

H

TA-32TA-32

FLEXIBLE SEALANT

SHOWER

STALL

SHOWER

STALL

TERRAZZO SHOWER BASE BELOW

2 1/2"

WATERPROOFING

MEMBRANE

SS CORNER STRIP

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

J K

J K

E W

E W

BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt

7/22/2021 12:52:40 PM

A-580

LEE

IN

T

E R

IO

R

D E

T A

IL

S

C

A D

E T

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

J

U L Y

W D

S D

RTA SUBMISSION

L E

E B

A R

R A

C K

S

W D

S F

P N

3" = 1'-0"A1

TERRAZZO PAN DETAIL @ SHOWER AND BATHROOM FL

3" = 1'-0"D1

TERRAZZO PAN DETAIL @ SHOWER

3" = 1'-0"D6

PLAN DETAIL - SHOWER PARTITION

CONTRACTOR TO COMPLETE BATHROOM FLOOD TEST PRIOR TO

INSTALLATION OF SHOWER BASES.

SCALE: 3" = 1'-0"

1/21/4

BASEMENT

-11' - 0" x7

ALUM BASE SHOE

2 1/2"

/2

STL ANGLE.

SEE STRU

LAMINATED SAFETY GLASS

W/ DECORATIVE PATTERN

INTERLAYER

AL REVEAL

STAINLESS STEEL TRIM (SCHLUTER

RENO-DECO OR EQUAL)

TERRAZZO - SEE FINISH PLAN

J BEAD TRIM

BRUSHED SST

ANODIZED CONCEALED

HEAD CHANNEL

1"

FINISH CEILING AS SCHEDULED

ABOVE CEILING BLOCKING

AS REQUIRED

DIAGONAL CFMF STUD

CROSS BRACING AS

REQUIRED

CONTINUOUS CFMF BOX

HEADER ENTIRE LENGTH OF

GLASS WALL

SEALANT JOINT TO MATCH HEADER,

ALIGN WITH CHANNEL LEGS

SHIM AS REQ'D

1/4" TEMPERED GLASS

FRAMELESS GLASS

SLIDING WINDOW

(SEE SPEC)

DIAGONAL CFMF STUD

CROSS BRACING AS

REQUIRED

CONTINUOUS CFMF BOX

HEADER ENTIRE LENGTH OF

WINDOW

2 cm QS

TRANSACTION

SHELF ON 3/4" MDF

3"X3" SUPPORT ANGLE

ROUTED IN MDF

LAMINATE

/4

QS COUNTER ON RAKKS

BRACKET (OR EQUAL)

COLOR MATCH SILICONE

LAMINATED FR-MDF

PANELS ON METAL CLEATS

2 CM QS

TRANSACTION

SHELF ON 3/4" MDF

1/4" TEMPERED GLASS

FRAMELESS GLASS

SLIDING WINDOW

(SEE SPEC)

4" @ RECEPTION

9"

FIRE / SECURITY

SHUTTER

2"

3"X3" SUPPORT

ANGLE ROUTED

IN MDF

AL TRIM AT SLOT

PERIMETER

DIAGONAL CFMF STUD

CROSS BRACING AS

REQUIRED

CONTINUOUS CFMF BOX

HEADER ENTIRE LENGTH OF

GLASS WALL

QS COUNTER ON RAKKS

BRACKET (OR EQUAL)

/8

LAMINATE

/4

SECURITY MESH

COLOR MATCH SILICONE

PAINT EXPOSED STEEL

TRACK TO MATCH

ADJACENT SURFACE

SOFFIT

5"

SLIDING

TRANSACTION

WINDOW TRACK

RECESSED INTO

SILL, PROVIDE

KEYED LOCK

FIRE RATED MINERAL CORE WIDTH PER SHUTTER MFR.

1/4" TEMPERED GLASS

FRAMELESS GLASS

SLIDING WINDOW

(SEE SPEC)

DIAGONAL CFMF STUD

CROSS BRACING AS

REQUIRED

CONTINUOUS CFMF BOX

HEADER ENTIRE LENGTH OF

WINDOW

2 cm QS

TRANSACTION

SHELF ON 3/4" MDF

/4

4"

SSUR COUNTER ON RAKKS

BRACKET (OR EQUAL)

COLOR MATCH SILICONE

2 cm QS

TRANSACTION

SHELF ON 3/4" MDF

3"X3" SUPPORT ANGLE

ROUTED IN MDF

LAMINATE

/4

4"

1/4" TEMPERED GLASS

FRAMELESS GLASS

SLIDING WINDOW

(SEE SPEC)

DIAGONAL CFMF STUD

CROSS BRACING AS

REQUIRED

CONTINUOUS CFMF BOX

HEADER ENTIRE LENGTH OF

WINDOW

1/2" AL REVEAL

BASEMENT

-11' - 0"

LAMINATED SAFETY GLASS

W/ DECORATIVE PATTERN

INTERLAYER

SHIM AS REQ'D

SEALANT TO MATCH BASE SHOE

TERRAZZO - SEE FINISH PLAN

J BEAD TRIM

BRUSHED SST

ANODIZED CONCEALED

HEAD CHANNEL

FINISH CEILING AS SCHEDULED

ABOVE CEILING BLOCKING

AS REQUIRED

DIAGONAL CFMF STUD

CROSS BRACING AS

REQUIRED

CONTINUOUS CFMF BOX

HEADER ENTIRE LENGTH OF

GLASS WALL

SEALANT JOINT TO MATCH HEADER,

ALIGN WITH CHANNEL LEGS

SHIM AS REQ'D

ALUM BASE SHOE: ATTACH W/

CONCRETE ANCHORS 12" O.C., TYP.

1/4" CLEAR SILICONE BUTT

JOINT AT CMU WALL

ALUM BASE SHOE

LAMINATED SAFETY GLASS

WITH DECORATIVE

INTERLAYER

1/4" CLEAR SILICONE BUTT

JOINT, TYP

ALIGN SEAMS OF GL SHOE

W/ JOINT, TYP

ALUM BASE SHOE

LAMINATED SAFETY GLASS

WITH DECORATIVE

INTERLAYERBASEMENT

-11' - 0" x14

SCHED BASE

EXISTING CONCRETE BEAM

3/4" SS ON 3/4" MDF; SS3

CFMF

1' - 6 3/4"

/2

/2

PAINTED PLASTER

JAMB OF SHUTTER

RECESSED INTO WALL

(ONE SIDE)

W A

L L

B L

W

QS TRANSACTION TOP

PAINT EXPOSED JAMB TO

MATCH WALL @ PIER

MISC. METAL SUPPORTS

SECURITY MESH

QS COUNTER TOP

SLIDING TRANSACTION

WINDOW TRACK

RECESSED INTO SILL,

PROVIDE KEYED LOCK

EX. PIER

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

LEE

BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt

7/22/2021 12:53:07 PM

A-590

IN

T

E R

IO

R

D E

T A

IL

S

C

H C

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

D e s ig n e r

A C

C h e c k e r

J

U L Y

W D

S D

RTA SUBMISSION

L E

E B

A R

R A

C K

S

W D

S F

P N

3" = 1'-0"A8

SECT DET @ GWS-1

3" = 1'-0"A5

WINDOW TYPE N @ CHC RECEPTION

3" = 1'-0"A1

WINDOW TYPE M @ CHC PHARMACY

3" = 1'-0"E8

WINDOW TYPE K DETAIL

3" = 1'-0"E6

WINDOW TYPE H - CHC APPT CLERK

3" = 1'-0"A7

ALT SECT DET @ GWS-1

3" = 1'-0"E4

PLAN DETAIL - GSW1 AT CMU

3" = 1'-0"F4

PLAN DETAIL - GSW1 TYP JOINT

1 1/2" = 1'-0"E1

SECTION DETAIL - BENCH AT UPTURNED BEAM

SCALE: 3" = 1'-0"

1/21/4

SCALE: 1 1/2" = 1'-0"

1 1/2" = 1'-0"G4

FIRE SHUTTER JAMB DETAILS

GENERAL PARTITION NOTES:

1. AT PARTITIONS TO RECEIVE CERAMIC TILE AND SHOWER STALL ASSEMBLIES (INCLUDING

CEILING OF SHOWER STALL) PROVIDE TYPE X GLASS MAT WATER-RESISTANT GYPSUM

TILE BACKING BOARD

2. WATER-RESISTANT GYPSUM BACKING BOARD MUST BE USED AT CEILINGS IN TOILET

ROOMS (EXCLUDING SHOWER CEILINGS), LOCKER ROOMS, LAUNDRY ROOMS, AND

JANITORIAL ROOMS

3. SEE FIN SCHED FOR FIN SUCH AS CERAMIC TILE, GLAZED OR POLISHED CMU TYPE,

PANELING, PAINT, ETC.

4. STANDARD CMU MUST BE 8" (NOM) THK UNO. NON-STANDARD CMU THK ARE INDICATED AS

FOLLOWS:

5. ALL PARTITIONS ARE TO EXTEND TO EXISTING STRUCTURE ABOVE, AND SEAL TO

STRUCTURE PER PARTITION TYPE REQUIREMENTS.

6. SLAB BETWEEN BASEMENT AND FL.1 IS A REQUIRED 2HR OCCUPANCY SEPARATION AND

MUST BE MAINTAINED AT ALL PENETRATIONS, FIRE-STOP AS REQUIRED TO MAINTAIN

RATING AT THIS EXISTING STRUCTURAL SLAB.

7. FIRE RATED PTN'S ARE IDENTIFIED IN OVERALL PLANS BY KEY & POCHE AS FOLLOWS:

8. PROVIDE RATED PTD PLYWOOD IN TELECOM ROOM AS REQUIRED BY THE TELECOM

DRAWINGS. FIREPROOFING LABEL TO REMAIN EXPOSED. SEE TELECOM SPECIFICATIONS.

M4

PARTITIONS

NONRATED

1 HR FIRE RATED

2 HR FIRE RATED

(1/2 HR) CMU SMOKE PTN

M6

EXISTING CONC. SLAB ABV

RUNNER - MIN SSMA 362T 250-43

FOR STUDS FROM 12' TO 22' LONG

HEAD DETAIL

PLAN DETAIL

POWDER ACTUATED FASTENERS

8" OC STAGGERED 1" EMBED

ACOUSTIC SEALANT EACH

SIDE, TYP. UL-APPROVED

FIRE-CAULKING AT RATED

ASSEMBLIES

DETAIL @ FLR

SEAL AROUND PENETRATING

DEVICES W/ACOUS SL

5/8" TYPE X GWB EA SIDE.

5/8" ACOUSTICAL GWB EA SIDE @

(1) LAYER 5/8" TYPE X GWB ONE SIDE,

(2) LAYERS 5/8" GWB ONE SIDE @

1/32" LEAD LINING @

AT ALL BATHROOMS PROVIDE 5/8" TYPE X GLASS MAT

WATER-RESISTANT GYPSUM TILE BACKING BOARD3 1/2" SAFB (STC 40 INTENT) @ G4A

G4S

6" SAFB (STC 40 INTENT) @ G6A

3 1/2" SAFB (STC 50 INTENT) @ G4AA

3 1/2" SAFB (STC 50 INTENT) @ G4AA-L

6" SAFB (STC 50 INTENT) @ G6AA

6" SAFB (STC 50 INTENT) @ G6AA-L 3 5/8" SSMA 362 S 137-33 STUDS @ 16" OC,

OTHER STUDS INDICATED ON PLANS

G3 (2 1/2" STUD)

SCHED BASE

MET RUNNER

ACOUS SL EA SIDE

/4

1" CLEAR BETWEEN TOP OF

STUDS & RUNNER

1 1/2" X 2" 19 GA CLIP

1 1/2" COLD ROLLED CHANNEL BRIDGING

ATTACH CLIPS TO STUD &

BRIDGING W/FRAMING SCREWS

FLR

G6 (6" STUD)

SECURITY MESH SEE SPEC 09 29 00

G4S (SECURITY)

GXAA

GXAB

GXAA-L

AT LEAD LINED WALL:

• 1/32" LEAD SHEET

BONDED TO GWB

• LEAD PLUG @ FIXINGS

• 1/16" THICK LEAD STRIP

@ PNL JT

- NON-RATED - NOM 8"

SEE FULL HGT DET

FULL HGT CMU PTN CERTIFIED FOR FIRE

RATING:

-1 HR FIRE RATING - UL U905 - NOM 8"

-2 HR FIRE RATING - UL U905 - NOM 8"

-2 HR FIRE RATING - UL U906 - NOM 6"

ALL CMU PTN'S ARE FROM FLR TO

UNDERSIDE OF STR ABV

HORZ TRUSS TYPE MAS REINF 16"

OC ALL "M" WALL TYPES

C1

VERTICAL REINFORCING INFORMATION

1 M8

2 M8

M8

WALL THICKNESS (IN)

MAX WALL HEIGHT (FT)

VERT WALL REINF

6 8

10'

#4 @ 48" OC

16'

#5 @ 48" OC

- 1/2" GYPSUM PLASTER DIRECTLY APPLIED TO

FINISHED SIDE OF MASONRY WALL

- 1/2" GYPSUM PLASTER DIRECTLY APPLIED TO

BOTH SIDES OF MASONRY WALL

M4G - GLAZED AND/OR POLISHED CMU - NOM. 4"

(3 5/8") AT STAIRWELLS. SEE INTERIORS (I)

DRAWINGS FOR FINISH DESIGNATION

-1/2 HR FIRE RATING - SMOKE PARTITION - NOM 8"S M8

2 M6

STANDARD CMU SHALL BE 8" (NOM) THK

UNO. NON-STANDARD CMU THK ARE

INDICATED AS FOLLOWS:

M6

M8P

M8P

- NON-RATED - NOM 4"M4

M4

PROVIDE CONT BOND BM

W/ #5 CONT WITHIN 2

COURSES OF TOP OF WALL

& GROUT TOP COURSE AT

REINF LOC (TYP)

* NON RATED: PACK W/ MINERAL

WOOL INS W/ SL EA SIDE

* FIRE RATED: UL APPROVED

FIRE STOP SYS

MASONRY PARTITION TOP

ANCHOR 48" O.C. WITH

ISOLATION SLEEVE, EMBED INTO

SECOND COURSE/ BOND BEAM

ALIGN WITH VERT REINF

UNDERSIDE OF

CONC SLAB OR BM

1" MIN TO 1 1/2" MAX

DIM MAY VARY W/ UL

APPROVED SYS

FOR THK

SEE PLANS

CUT CMU AT TOP COURSE AS

REQUIRED

TOP SIDE OF

CONC SLAB

VINYL COVE BASE

DUCT

EGE OF SLAB OPENING

1 M6

S G3AS G3A

S G3P

2 G3A

PTN TYPE CONT BTWN

DOUBLE

ARROWHEADS

PTN CHANGES

TYPE WHERE

ARROWHEADS

MEET

M6

INDICATES PTN TYPE WHEN

TYPE IS CONSISTENT FOR

LENGTH OF WALL SEGMENT

2 M3PB

FIRE RATING

• NUMBER OF HOURS

• IF NO NUMBER PTN

IS NON-RATED

• S - SMOKE PTN

(1/2 HOUR)

STUD SIZE OR

FURRING/THICKNESS

MATERIAL

G - GWB STUD PTN

F - FURRING W/GWB

M - CMU

S - SHAFT WALL

T - TILE WALL

SPECIAL ATTRIBUTE

A - ACOUSTICAL

L - LEAD LINED

P - PLASTER

PB - PLASTER BOTH

SIDES OF WALL

G - GLAZED AND/OR

POLISHED CMU

LEAD THICKNESS

1/32" OF LEAD

NOTES:

1. FOR ALL FURRING TYPES GWB TO EXTEND TO

STRUCTURE ABV

2. FOR EXISTING EXTERIOR WALLS ISOLATE MET FURR FROM

CONC OR MASONRY WITH SPRAY-FOAM INSULATION

3. EXTEND ALL FURRING STUDS TO STRUCTURE ABV

4. ALL FURRING TYPES FXX-L TO HAVE 1/32" LEAD LINING

PLAN

PLAN

F4P

F4

F4A

F3

MET STUD BRACE @

4'-0" OC VERT

5/8" TYPE X GWB ON 3 5/8"

MET STUDS @ 1'-4" OC

SAFB @ F4A

POULTRY NETTING OR

EQUIVALENT AS REQUIRED

TO RETAIN INSULATION

3/4" FIRE RETARDANT

PLYWOOD SHEATHING

5/8" ABUSE RESISTANT GWB UNO.

TYPE X FIRE RATED GWB WHERE

REQUIRED FOR RATING

1/2" GYPSUM PLASTER (TWO-COAT)

MET STUDS @ 1'-4" OC

MET STUD BRACE @

4'-0" OC VERT

VARIES, SEE PLAN

AT ALL BATHROOMS PROVIDE 5/8"

TYPE X GLASS MAT WATER

RESISTANT GYPSUM TILE

BACKING BOARD

5/8" TYPE X GLASS MAT WATER

RESISTANT GYPSUM TILE BACKING

BOARD F1

HAT CHANNEL

F3P

F2A

F2A-L

PLAN

F6

F6-L

MET STUD BRACE @

4'-0" OC VERT

5/8" TYPE X GWB ON 6"

MET STUDS @ 1'-4" OC

PLAN @ WALL

PROVIDE FIRE RATED CABINET

WHERE SHOWN IN RATED WALL

CONSTRUCTION

CABINET FRAME

CABINET DOOR

/2

M A

X

FIRE EXTINGUISHER

TUB

MOUNTING SCREW

PLAN @ WALL

SECTION @ SLAB

UL APPROVED

2HR FIRESTOP

FIRESTOP ALL

PENETRATIONS

THROUGH RATED

CONSTRUCTION

OPENING AS REQ'D

LOCATE CJ 2'-0" FROM

"T" PTN JUNCTION

KEEP JT FREE

OF MORTAR

INTERRUPT HORZ TRUSS

TYPE REINF @ EJ

SHEAR KEY

3/8" JOINT W/ BACKER ROD & SL

(BOTH SIDES)

PROVIDE SHEAR KEY AT

PTN'S WHICH ARE NOM

6" WIDE AND WIDER

AT FIRE RATED PTN

PROVIDE FIRE STOP SYS

LOCATE CJ MIN 1'-0"

FROM ANY OPENINGS

EDGE OF SHAFT OPNG

HEAD DETAIL

PLAN DETAIL

FIRE & SMOKE SL

DETAIL @ FLR

SHAFT SIDE (UNFINISHED)

1" LINER PANEL

GWB CAT @ ELEVATOR SHAFT

ONLY, SCREW FIXED TO STUDS.

CANT NOT REQD @

PROJECTIONS OF 2" OR LESS

J RUNNER

RUNNER TRACK

FLR

5 1/4"

3 3/4"

MIN

@ 2 1/2" C-H STUDS

@ 4" C-H STUDS

ROOM SIDE (FINISHED)

2 1/2" C-H (212CH-34) MET

STUDS @ 2'-0" OC

4" C-H (400CH-34) MET STUDS @

2'-0" OC @ELEVATOR SHAFTS

2 LAYERS 5/8" TYPE X

FIRE RATED GWB

EDGE OF SHAFT OPNG

2 HR UL HW D 0603

2 HR UL DES U415

2 HR UL BW S 0016

SCHED BASE

FIRE & SMOKE SL

T-2 SCHEDULED TILE

MORTAR BED

3-COAT GYPSUM PLASTER

DIRECTLY APPLIED TO FINISHED

SIDE OF (E) STRUCTURE

NOTES:

1. EXPOSED EXISTING CONCRETE

STRUCTURE TO BE COATED IN 3/4"

PLASTER TO MAINTAIN 2HR RATING

& PROVIDE A FINISHED SURFACE.

WALL TILE ON THINSET

CEMENTITIOUS BOND

COAT

WATERPROOFING

MEMBRANE

T2

T1

SCALE: 1 1/2"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

J K

J K

E W

E W

BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt

7/22/2021 12:53:17 PM

A-600

LEE

P A

R T

IT

IO

N T

Y P

E S

D

E T

A

IL

S

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

J

U L Y

W D

S D

RTA SUBMISSION

L E

E B

A R

R A

C K

S

W D

S F

P N

3" = 1'-0"A3

GWB PARTITION TYPES G4(A)

3" = 1'-0"A1

CMU PARTITION TYPES M

1 1/2" = 1'-0"E1

FULL HEIGHT CMU PARTITION BRACING @

CONC. STRUC. & CMU @ SLAB OPENING

3" = 1'-0"D8

PARTITION LEGEND

3" = 1'-0"D6

FURRING PARTITION TYPES F

1 1/2" = 1'-0"F6

FIRE EXTINGUISHER CABINET DETAIL

1 1/2" = 1'-0"D3

FIRESTOP DETAIL

3" = 1'-0"F3

CONTROL JOINT @ INT. MASONRY PARTITION

3" = 1'-0"A6

SHAFTWALL PARTITION TYPE 2S3 - 2 HR

RATED - FINISHED 1 SIDE

3" = 1'-0"F8

MISC. PARTITION TYPES

6" STUDS AT ATFP FRAMING

FOR EXTERIOR OPENINGS,

3 5/8" STUDS AT ALL OTHER

EXTERIOR WALL FURRING

CONDITIONS

METAL LATH

3/4" FRT PLYWOOD

1 LAYER 5/8" IMPACT

RESISTANT GYPSUM

WALLBOARD

7/16" GYPSUM

PLASTER

6" CFMF STUD

6" CFMF STUD

3-5/8" CFMF STUD

EXISTING STRUCTURE

EXTERIOR INTERIOR

CLOSED-CELL SPRAY

FOAM

INSULATION/AVB,

R-25 MINIMUM

(WALLS)

F6P

F4P

2" +/- THERMAL BREAK2" +/- THERMAL BREAK

LEAD LINED GWB

FULL HGT X 2" WIDE LEAD

STRIP AT JT OF LEAD LINED

PNLS SAME THK AS GWB

LEAD LINING

SHIMS @ INTERMEDIATE

STUDS

3/8" Ø LEAD PLUGS SAME

THK AS GWB LINING @ ALL

FIXINGS

ROOM SIDECORRIDOR SIDE

SHEET LEAD LINING SAME

THK AS GWB LEAD LINING

UTILITY BOX

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

J K

J K

E W

E W

BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt

7/22/2021 12:53:27 PM

A-601

LEE

P A

R T

IT

IO

N S

C H

E D

U L E

D

E T

A

IL

S

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

J

U L Y

W D

S D

RTA SUBMISSION

L E

E B

A R

R A

C K

S

W D

S F

P N

PARTITION SCHEDULE

FIRE

RATING

WALL

TYPE DESCRIPTION WIDTH

FIRE

TEST

ASSEMBLY

CODE

STC

INTENT TOP OF WALL

HEAD

DETAIL

BASE

DETAIL TYPE COMMENTS

- F1 7/8" Furring w/ 5/8" GWB one side - Non Rated 1 1/2" - C1010145 - BTM OF SLB ABV - A3/A-600 -

- F2A 1 1/2" Z Furring w/ 5/8" GWB one side - Non Rated 2 1/4" - C1010145 - BTM OF SLB ABV - A3/A-600 -

- F2A-L 1 1/2" Z Furring w/ 5/8" GWB one side and 1/32" lead lining - Non Rated 2 1/4" - C1010145 - BTM OF SLB ABV - A3/A-600 -

- F3 2 1/2" stud w/ 5/8" GWB one side - Non Rated 3 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -

- F3P 2 1/2" stud w/ 7/16" Plaster one side - Non Rated 4 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -

- F4 3 5/8" stud w/ 5/8" GWB one side 4 1/2" - C1010145 BTM OF SLB ABV A3/A-600 A3/A-600 -

- F4 3 5/8" stud w/ 5/8" GWB one side - Non Rated 4 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -

- F4A 3 5/8" stud w/ 5/8" GWB one side w/ Acoustical Insulation - Non Rated 4 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -

- F4P 3 5/8" stud w/ 7/16" Plaster one side - Non Rated 5 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -

S F4P 3 5/8" stud w/ 7/16" Plaster one side - Smoke Rated 4 3/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -

- F6 6" stud w/ 5/8" GWB one side - Non Rated 6 3/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -

- F6-L 6" stud w/ 5/8" GWB one side and 1/32" lead lining - Non Rated 6 3/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -

- F6P 6" stud w/ 4" Spray Foam Insulation and 5/8" Plaster one side 9 3/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -

- G4 3 5/8" stud w/ 5/8" GWB ea side - Non Rated 5" - C1010145 37 BTM OF SLB ABV A3/A-600 A3/A-600 -

1 G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - 1HR Rated 5" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -

1 G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - 1HR Rated 5 1/2" - C1010145 45 BTM OF SLB ABV A6/A-600 A6/A-600 -

2 G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - 2HR Rated 5" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -

- G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 5" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -

- G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 5 1/2" - C1010145 45 BTM OF SLB ABV A6/A-600 A6/A-600 -

1 G4AA 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - 1 HR Rated 5" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -

- G4AA 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 5" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -

- G4AAL 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation and 1/32" lead lining - Non Rated 5" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -

1 G4S 3 5/8" stud w/ 5/8" GWB ea side w/ Security Mesh and Acoustical Insulation - 1HR Rated 5" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -

- G6 6" stud w/ 5/8" GWB ea side - Non Rated 7 1/4" - C1010145 37 BTM OF SLB ABV A3/A-600 A3/A-600 -

- G6A 6" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 7 1/4" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -

- G6A 6" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 8" - C1010145 45 BTM OF SLB ABV A3/A-600 A3/A-600 -

- G6AA 6" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 7 1/4" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -

- G6AAL 6" stud w/ 5/8" GWB ea side w/ Acoustical Insulation and 1/32" lead lining - Non Rated 7 1/4" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -

- GWS-1 1" Interior Glass Wall - - - - - - CHC SCOPE

- M4P 4" (nom) CMU partition w/ 7/16" Plaster one side - Non Rated 4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

S M4P 4" (nom) CMU partition w/ 7/16" Plaster one side - Smoke Rated 4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

2 M6 6" (nom) CMU partition - 2HR Rated 5 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

1 M6P 6" (nom) CMU partition w/ 7/16" Plaster one side - 1HR Rated 6" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

2 M6P 6" (nom) CMU partition w/ 7/16" Plaster one side - 2HR Rated 6" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

- M6P 6" (nom) CMU partition w/ 7/16" Plaster one side - Non Rated 6" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

1 M6PB 6" (nom) CMU partition w/ 7/16" of Plaster both sides - 1HR Rated 6 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -

2 M6PB 6" (nom) CMU partition w/ 7/16" of Plaster both sides - 2HR Rated 6 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -

- M6PB 6" (nom) CMU partition w/ 7/16" of Plaster both sides - Non Rated 6 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -

S M6PB 6" (nom) CMU partition w/ 7/16" Plaster both sides - Smoke Rated 6 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -

2 M8 8" (nom) CMU partition - 2HR Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

- M8 8" (nom) CMU partition - Non Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

S M8 8" (nom) CMU partition - Smoke Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

- M8G 8" (nom) Glaze-Face CMU partition - 2HR Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

2 M8G 8" (nom) Structural Glaze-Face CMU partition - 2HR Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 PLEASE SEE STRUCTURAL DRAWINGS

1 M8P 8" (nom) CMU partition w/ 7/16" Plaster one side - 1HR Rated 8" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

2 M8P 8" (nom) CMU partition w/ 7/16" Plaster one side - 2HR Rated 8" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

S M8P 8" (nom) CMU partition w/ 7/16" Plaster one side - Smoke Rated 8" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -

S M8PB 8" (nom) CMU partition w/ 7/16" Plaster both side - Smoke Rated 8 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -

1 M8PB 8" (nom) CMU partition w/ 7/16" Plaster both sides - 1HR Rated 8 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -

2 M8PB 8" (nom) CMU partition w/ 7/16" Plaster both sides - 2HR Rated 8 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -

2 S3 2 1/2" CH stud w/ liner panel and 5/8" GWB - 2HR Rated 4 3/4" U415 C1010145 43 BTM OF SLB ABV A6/A-600 A6/A-600 -

1 S3 4" CH stud w/liner panel and 1 layers 5/8" GWB - 1HR Rated 4 3/4" U415 C1010145 43 BTM OF SLB ABV A6/A-600 A6/A-600 -

2 S3P 2 1/2" CH stud w/liner panel and 5/8" GWB, 7/16" Plaster one side - 2HR Rated 5 1/4" U415 C1010145 43 BTM OF SLB ABV A6/A-600 A6/A-600 -

2 S4 4" CH stud w/liner panel and 1 layers 5/8" GWB - 1HR Rated 6 1/4" U415 C1010145 43 BTM OF SLB ABV A6/A-600 A6/A-600 -

3" = 1'-0"A7

TYP FURRING DETAIL AT EXT WALL

SCALE: 3" = 1'-0"

1/21/4

3" = 1'-0"D7

LEAD LINED PARTITION - DETAILS

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

J K

J K

E W

E W

BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt

7/22/2021 12:53:39 PM

A-610

LEE

D O

O R

S C

H E

D U

L E

E

X T

E R

IO

R

S

U B

-B A

S E

M E

N T

B A

S E

M E

N T

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T

F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

J

U L Y

W D

S D

RTA SUBMISSION

L E

E B

A R

R A

C K

S

W D

S F

P N

DOOR SCHEDULE - SUBBASEMENT

ROUGH

OPENING

DOOR SIZE DOOR FRAME

FIRE

RATING SMOKE HW

ELEC

REMARKSNUMBER WIDTH

LEAF

A

LEAF

B HEIGHT TYPE MATL GLAZ

UNDER

CUT TYPE MATL GLAZ P S F

LB001.1 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 05 AL TG G4 -- -- 0 X 0002 -- -- -- ALUM. STOREFRONT GLASS DOOR

LB001.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 07 WD FR PB6 -- -- 90 0025 -- -- -- --

LB001.3 5' - 4" 5' - 0" 2' - 6" 2' - 6" 7' - 0" 01 WD PB6 -- -- 20 X 0050 -- -- -- --

LB001.4 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD PB6 -- -- 20 X 0026 -- -- -- --

LB001.5 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD PB6 -- -- 20 X 0026 -- -- -- --

LB001.6 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD PB6 -- -- 20 X 0016 -- -- -- --

LB002 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 05 AL TG G4 -- -- 0 X 0002 -- -- -- ALUM. STOREFRONT GLASS DOOR

LB003.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 03 WD FP G4 -- -- 20 X 0021 -- -- -- --

LB003.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0019 -- -- -- --

LB004 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LB005.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --

LB005.2 3' - 4" 3' - 0" 7' - 0" -- -- G4 -- -- 0 -- -- -- -- CASED OPENING

LB006 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LB007 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LB008 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --

LB009 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --

LB010.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0016 -- -- -- --

LB010.2 5' - 4" 5' - 0" 2' - 6" 2' - 6" 7' - 0" 01 HM G4 -- -- 20 X 0015 -- -- -- --

LCS01 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 60 0051 -- CR -- PEEPHOLE, INTERCOM W/ DOOR RELEASE

LCS02 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0048.1 -- CR -- --

LCS05 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LCS07 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LCS08 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LCS09 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0036 -- CR -- --

LCS10 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LCS11 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LE-S-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"

LE-S-2 4' - 4" 4' - 0" 4' - 0" 7' - 0"

LE-S-3 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 HM P6 -- -- 90 0058 -- -- -- --

LS0.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 02 WD FP G4 -- -- 20 X 0013 -- CR -- --

LS0.2 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 02 WD FP PB6 -- -- 90 0024 -- CR -- --

LS0.3 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0052 -- -- -- --

LS01.1 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 HM PB6 -- -- 90 0022 -- -- -- --

LS01.2 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" PB6 -- -- 90 0023 -- CR -- --

LS02 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" P6 -- -- 90 0049 -- CR -- --

LS03 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" G4 -- -- 90 0006 -- CR -- --

LS05 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" PB6 -- -- 20 X 0009 -- CR -- --

LS06 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0016 -- -- -- --

LS07 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0048 -- CR -- --

LS09 6' - 4" 6' - 0" 3' - 0" 3' - 0" 8' - 0" 05 AL TG -- -- -- 0 0045 P CR -- ALUM. STOREFRONT GLASS DOOR, AUTO OPENER

LS-S-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT9 -- -- 90 0057 -- -- -- EXISTING OPENING V.I.F.

LS-S-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT9 -- -- 90 0046 -- -- -- EXISTING OPENING V.I.F.

LS-S-3 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 HM P8 -- -- 90 0008 -- -- -- --

DOOR SCHEDULE - BASEMENT

ROUGH

OPENING

DOOR SIZE DOOR FRAME

FIRE

RATING SMOKE HW

ELEC

REMARKSNUMBER WIDTH

LEAF

A

LEAF

B HEIGHT TYPE MATL GLAZ

UNDER

CUT TYPE MATL GLAZ P S F

L001.1 7' - 4" 7' - 0" 3' - 6" 3' - 6" 7' - 0" 01 HM 3/4" G4 -- -- 60 0029 -- CR -- --

L001.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM G4 -- -- 60 0011 -- -- -- --

L001.3 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" G4 -- -- 90 0028 -- -- -- --

LC001 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LC01.1 4' - 4" 4' - 0" 4' - 0" 7' - 0" 02 WD FP G4 -- -- 20 X 0020 -- CR FA HOLD OPEN

LC01.2 4' - 4" 4' - 0" 4' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0020 -- CR FA HOLD OPEN

LC01.3 4' - 4" 4' - 0" 4' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0013 -- CR -- --

LC002 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LC003 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 20 X 0016 -- CR -- --

LC004 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" P6 -- -- 60 0014 -- CR -- --

LC005 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LC006 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 20 X 0033 -- CR -- --

LC007 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LC008 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LC009 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 60 0016 -- -- -- --

LC011.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --

LC011.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LC012.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 03 WD FP G4 -- -- 20 X 0048.1 -- CR -- --

LC012.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0016 -- -- -- --

LC014 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LC015 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 20 X 0031 -- -- -- --

LC017 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LC018 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD G4 -- -- 20 X 0018 -- -- -- --

LC019 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LC020 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --

LC021 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LC022 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LC023 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LC024 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LC025 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LC026 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --

LC027 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0016 -- -- -- --

LC028 3' - 10" 3' - 6" 3' - 6" 7' - 0" 02 WD FP G4 -- -- 20 X 0018 -- -- -- --

LC029 4' - 4" 4' - 0" 4' - 0" 7' - 0" 02 WD FP G4 -- -- 20 X 0030 -- -- -- --

LC030.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC030.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC031 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC032.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC032.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC033 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC034 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC035 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC036 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC037 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC038 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC039 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --

LC040 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --

LE-B-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"

LE-B-2 4' - 4" 4' - 0" 4' - 0" 7' - 0"

LS-B-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0027 -- CR -- EXISTING OPENING V.I.F.

LS-B-2.1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0027 -- CR -- EXISTING OPENING V.I.F.

LS-B-2.2 3' - 5" 3' - 2" 3' - 2" 4' - 0" SST -- -- -- 0 0054 -- -- FA STAIR GATE. SEE SHEET A-501

DOOR SCHEDULE - EXTERIOR

ROUGH

OPENING

DOOR SIZE DOOR FRAME

FIRE

RATING SMOKE HW

ELEC

REMARKSNUMBER WIDTH

LEAF

A

LEAF

B HEIGHT TYPE MATL GLAZ

UNDER

CUT TYPE MATL GLAZ P S F

EX01 10' - 7" 6' - 0" 3' - 0" 3' - 0" 8' - 0" 05 AL TG -- -- -- 0 0002.1 P CR -- EXTERIOR ALUM. STOREFRONT GLASS DOOR, AUTO

OPENER

EX02 4' - 0" 3' - 8" 3' - 8" 7' - 0" 01 WD EX2 -- -- 90 0003 -- -- -- RESTORE EXISTING WOOD DOOR. SEE SHEET A-614

EX03 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 WD EX2 -- -- 90 0001 -- -- -- RESTORE EXISTING WOOD DOOR. SEE SHEET A-614

EX04 6' - 0" 5' - 8" 2' - 10" 2' - 10" 7' - 0" 01 HM ECM1 -- -- 90 0004 -- CR -- INSULATED EXTERIOR STEEL DOOR, FACTORY

FINISHED. EXISTING OPENING V.I.F.

EX05 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 HM ECM1 -- -- 0 0056 -- -- -- SEE SHEET A-511

EX06 4' - 4" 4' - 0" 4' - 0" 7' - 0" 01 SST ECM2 -- -- 90 0005 -- -- -- EXTERIOR ACCESSIBLE INSULATED STEEL DOOR. SEE

SHEET A-614

EX103 10' - 0" 6' - 1" 7' - 6"

EX108 10' - 0" 6' - 1" 7' - 6"

FA01 3' - 8" 3' - 8" 7' - 6" 01 HM -- -- -- 0 -- -- -- -- --

EX1

EX1

RESTORE EXISTING WOOD DOOR. SEE SHEET A-614

RESTORE EXISTING WOOD DOOR. SEE SHEET A-614

DOOR FRAME NOTES:

1. FRAME TYPES "EX" - AN EXISTING FRAME TO REMAIN IN PLACE FOR REPAIR AND REFINISHING. SEE SHEET A-614.

2. ELEVATOR DOOR FRAMES BY ELEVATOR MANUFACTURER

3. DOOR FRAMES AT INTEGRAL ROOF SCREEN DOOR ASSEMBLIES ARE CUSTOM FABRICATED

4. ALL EXISTING ROUGH OPENINGS MUST BE V.I.F.

3' - 0"

3' - 0"

3' - 0"

3' - 0"

WD

WD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

J K

J K

E W

E W

BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt

7/22/2021 12:53:53 PM

A-611

LEE

D O

O R

S C

H E

D U

L E

S

T

N

D

R D

T

H

T

H

R O

O F

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T

F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

J

U L Y

W D

S D

RTA SUBMISSION

L E

E B

A R

R A

C K

S

W D

S F

P N

DOOR SCHEDULE - FIRST FLOOR

ROUGH

OPENING

DOOR SIZE DOOR FRAME

FIRE

RATING SMOKE HW

ELEC

REMARKSNUMBER WIDTH

LEAF

A

LEAF

B HEIGHT TYPE MATL GLAZ

UNDER

CUT TYPE MATL GLAZ P S F

L101.1 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0048 -- CR -- --

L101.2 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD G4 -- -- 20 X 0012 -- -- -- --

L102 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" P8 -- -- 60 0017 -- CR -- --

L103 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 WD PB8 -- -- 90 0042 -- CR -- HOLD OPEN.

L104 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0044 -- -- -- --

L105 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --

L106 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --

L107 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0039 -- -- -- --

L108 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 WD PB8 -- -- 90 0042 -- CR -- HOLD OPEN.

L109.2 4' - 4" 4' - 0" 4' - 0" 7' - 0" 02 HM FP PB8 -- -- 20 X 0035 -- CR -- --

L110.1 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 60 0036 -- CR -- --

L110.2 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 20 0037 -- CR -- --

L111.1 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0038 -- CR -- --

L112 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 HM PB8 -- -- 90 0047 -- CR -- --

L113 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0043 -- CR -- --

L114.1 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0036 -- CR -- --

L114.2 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0036 -- CR -- --

LE-1-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"

LS-1-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

LS-1-2.1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

LS-1-2.2 3' - 5" 3' - 2" 3' - 2" 4' - 0" SST -- -- -- 0 0054 -- -- FA STAIR GATE. SEE SHEET A-501

DOOR SCHEDULE - SECOND FLOOR

ROUGH

OPENING

DOOR SIZE DOOR FRAME

FIRE

RATING SMOKE HW

ELEC

REMARKSNUMBER WIDTH

LEAF

A

LEAF

B HEIGHT TYPE MATL GLAZ

UNDER

CUT TYPE MATL GLAZ P S F

L201 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0017 -- CR -- --

L202 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0019 -- -- -- --

L203 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0018 -- -- -- --

L204 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0044 -- -- -- --

L205.1 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0048 -- CR -- --

L205.2 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0048 -- CR -- --

L206 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB6 -- -- 90 0017 -- CR -- --

L207 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0010 -- -- -- --

L208 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --

L2001 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2002 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2003 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2004 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2005 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2006 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2007 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2008 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2009 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2010 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2011 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2012 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2013 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2014 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L2015 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

LE-2-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"

LS-2-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

LS-2-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

DOOR SCHEDULE - THIRD FLOOR

ROUGH

OPENING

DOOR SIZE DOOR FRAME

FIRE

RATING SMOKE HW

ELEC

REMARKSNUMBER WIDTH

LEAF

A

LEAF

B HEIGHT TYPE MATL GLAZ

UNDER

CUT TYPE MATL GLAZ P S F

L301 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0017 -- CR -- --

L302 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0019 -- -- -- --

L303 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0018 -- -- -- --

L304 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0044 -- -- -- --

L305.1 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0048 -- CR -- --

L305.2 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0016 -- -- -- --

L306 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB6 -- -- 90 0017 -- CR -- --

L307 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0039 -- -- -- --

L308 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --

L3001 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3002 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3003 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3004 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3005 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3006 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3007 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3008 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3009 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3010 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3011 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3012 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3013 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3014 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3015 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L3016 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

LE-3-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"

LS-3-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

LS-3-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

DOOR SCHEDULE - FOURTH FLOOR

ROUGH

OPENING

DOOR SIZE DOOR FRAME

FIRE

RATING SMOKE HW

ELEC

REMARKSNUMBER WIDTH

LEAF

A

LEAF

B HEIGHT TYPE MATL GLAZ

UNDER

CUT TYPE MATL GLAZ P S F

L401 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0017 -- CR -- --

L402 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0019 -- -- -- --

L403 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0018 -- -- -- --

L404 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0044 -- -- -- --

L406 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB6 -- -- 90 0017 -- CR -- --

L407 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0039 -- -- -- --

L408 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --

L4001 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4002 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4003 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4004 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4005 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4006 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4007 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0032 -- CR -- --

L4008 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4009 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4010 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4011 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4012 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4013 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4014 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4015 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4016 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4017 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4018 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L4019 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

LE-4-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"

LS-4-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

LS-4-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

DOOR SCHEDULE- FIFTH FLOOR

ROUGH

OPENING

DOOR SIZE DOOR FRAME

FIRE

RATING SMOKE HW

ELEC

REMARKSNUMBER WIDTH

LEAF

A

LEAF

B HEIGHT TYPE MATL GLAZ

UNDER

CUT TYPE MATL GLAZ P S F

L501 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0017 -- CR -- --

L502 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0019 -- -- -- --

L503 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0018 -- -- -- --

L504 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0044 -- -- -- --

L506 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB6 -- -- 90 0017 -- CR -- --

L507 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0039 -- -- -- --

L508 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --

L5001 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5002 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5003 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5004 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5005 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5006 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5007 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0032 -- CR -- --

L5008 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5009 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5010 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5011 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5012 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5013 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5014 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5015 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5016 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5017 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5018 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

L5019 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --

LE-5-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"

LS-5-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

LS-5-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.

DOOR SCHEDULE- ROOF LEVEL

ROUGH

OPENING

DOOR SIZE DOOR FRAME

FIRE

RATING SMOKE HW

ELEC

REMARKSNUMBER WIDTH

LEAF

A

LEAF

B HEIGHT TYPE MATL GLAZ

UNDER

CUT TYPE MATL GLAZ P S F

L601 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM ECM1 -- -- 90 0041 -- CR -- INSULATED EXTERIOR STEEL DOOR, FACTORY FINISHED

LR-1 6' - 4" 6' - 0" 3' - 0" 3' - 0" 11' - 0" 01 STL -- -- -- 0 0053 -- -- -- ROOF SCREEN DOOR ASSEMBLY, SEE A-512 / E1

LR-2 6' - 4" 6' - 0" 3' - 0" 3' - 0" 11' - 0" 01 STL -- -- -- 0 0053 -- -- -- ROOF SCREEN DOOR ASSEMBLY, SEE A-512 / E1

LR-3 6' - 4" 6' - 0" 3' - 0" 3' - 0" 11' - 0" 01 STL -- -- -- 0 0053 -- -- -- ROOF SCREEN DOOR ASSEMBLY, SEE A-512 / E1

LS-6-1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM ECM1 -- -- 90 0040 -- CR -- INSULATED EXTERIOR STEEL DOOR, FACTORY FINISHED.

EXISTING OPENING V.I.F. SEE SHEET A-520

LS-6-2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM ECM1 -- -- 90 0040 -- CR -- INSULATED EXTERIOR STEEL DOOR, FACTORY FINISHED.

EXISTING OPENING V.I.F. SEE SHEET A-520

DOOR FRAME NOTES:

1. FRAME TYPES "EX" - AN EXISTING FRAME TO REMAIN IN PLACE FOR REPAIR AND REFINISHING. SEE SHEET A-614.

2. ELEVATOR DOOR FRAMES BY ELEVATOR MANUFACTURER

3. DOOR FRAMES AT INTEGRAL ROOF SCREEN DOOR ASSEMBLIES ARE CUSTOM FABRICATED

4. ALL EXISTING ROUGH OPENINGS MUST BE V.I.F.

FIRST FLOOR

0" x2x3 3"

ROUGH OPENING

4' - 4"3"

6' - 6"22' - 0"

INSULATED

FACTORY-FINISHED

EXTERIOR STEEL

DOOR

NEW CAST-IN-PLACE

CONCRETE LANDING

NEW CAST-IN-PLACE

CONCRETE RAMP

EXTERIOR GUARD

AND HANDRAIL,

PAINTED BLACK

A3

A-614

D3

A-614

R4

4' - 0"

BASEMENT

-11' - 0"

SUB-BASEMENT

-22' - 0" x7 x8 V.I.F.

10' - 7"

2" 1' - 11 1/2" 2" 6' - 0" 2" 1' - 11 1/2" 2"

V .I

.F

6' - 0"

ALUMINUM

STOREFRONT AND

ENTRANCE DOORS

NEW CAST-IN-PLACE

CONCRETE STAIRS &

LANDING

MASONRY JOINT

CLEANING AND

RESTORATION

A7

A-615

D3

A-616

B3

A-616

A3

A-616

A1

A-616

B1

A-616

D1

A-616

D9

A-616

E9

A-616 6" SQUARE BOLLARD

WITH ADA PUSH

BUTTON

EXTERIOR SINGLE

PIPE HANDRAIL,

PAINTED BLACK

EQEQ EQEQ

FIRST FLOOR

0"

1' - 8"

3 1/2"

LEAF B

3' - 0"1"

LEAF A

3' - 0"

3 1/2"

1' - 8"

RESTORE HISTORIC

WOOD ENTRANCE

DOORS

REPAIR / RESTORE

WINDOWS IN

HISTORIC WOOD

ENTRANCE DOORS

RESTORE AND

REINSTALL BRONZE

RAILINGS

V .I

.F

V

IF6

REPAIR EXISTING

CONCRETE SURFACE

REPLACE REMOVABLE

MULLION (BEYOND)

EXISTING DOOR TRIM

TO BE REMOVED,

REFINISHED, AND

REINSTALLED

V.I.F.

10' - 0"

EXISTING STONE

LANDING TO REMAIN.

REPOINT JOINTS

6' - 1"

C6

A-614

EX04

5' - 8"

INSULATED

FACTORY-FINISHED

EXTERIOR STEEL

DOOR

V.I.F.

6' - 0"

V .I

.F

E3

A-614

7 1/2" 1 1/2" 7 1/2"

6' - 0"

V.I.F.

6' - 4"

V .I .F

EX03

A6

A-614

SIM

BASEMENT

-11' - 0"

7 1/2" 1 1/2" 7 1/2"

3' - 8"

RESTORE HISTORIC

WOOD ENTRANCE

DOORS

E1

A-590

V.I.F.

4' - 0"

V .I

.F

A6

A-614

SIM

1 2

WIDTH

LEAF A LEAF B

9" 3"

ALL FRAMES - HM, (SEE PARTITION TYPE TAGGED AT EACH DOOR FRAME)

GWB

GWB W/ PLASTER (BOTH SIDES)

GWB W/ PLASTER (ONE SIDE)

MASONRY W/ PLASTER (BOTH SIDES)

MASONRY W/ PLASTER (ONE SIDE)

(CERAMIC TILE AT BATHROOMS TO ABUT FRAME BACK-BEND)

6" 2'-0" 6"

GLAZING REQUIREMENTS:

1. ALL INTERIOR GLAZING MUST BE TEMPERED SAFETY GLASS

(TSG) UNO

2. GLAZING IN RATED DOORS TO BE FIRE PROTECTIVE

LAMINATED GLASS (FP)

9" 6"

1. DOOR SCHEDULE IS PART OF AN OVERALL DOOR SYSTEM; COORDINATE DOOR SCHEDULE WITH HARDWARE SCHEDULE, ACCESS

CONTROL, SECURITY, AND ELECTRICAL. PROVIDE COMPLETE AND OPERABLE SYSTEM.

2. COORDINATE CARD READER AND SECURITY WITH ALL DISCIPLINES. PROVIDE ALL CARD READERS INDICATED ON CONTRACT DOCUMENTS AND PROVIDE ALL NECESSARY COMPONENTS AND INFRASTRUCTURE FOR A COMPLETE AND OPERABLE SYSTEM

INTEGRATED INTO CAMPUS CONTROL SYSTEM.

3. COORDINATE ALL ELECTRIFIED AND LOW-VOLTAGE DEVICES WITH ALL DISCIPLINES. PROVIDE ALL NECESSARY POWER, COMPONENTS AND INFRASTRUCTURE FOR A COMPLETE AND OPERABLE SYSTEM.

4. WHERE DOORS HAVE LOUVERS REFERENCE MECHANICAL FOR CFM REQUIREMENTS

5. WHERE RATED DOORS HAVE VISION PANELS, VISION PANELS TO HAVE RATING TO MATCH DOOR AND BE PROVIDED WITH LABEL

INDICATING COMPLIANCE.

6. UNDERCUT BOTTOM OF RATED DOORS 3/4" MAXIMUM PER NFPA 80, 4.8.4.1

7. DOORS IN 1/2HR. SMOKE PARTITIONS TO BE 20 MINUTE RATED.

8. ALL DOORS TO BE EXTRA HEAVY DUTY DOORS.

GENERAL DOOR NOTES:

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

J K

J K

E W

E W

BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt

7/22/2021 12:54:10 PM

A-612

LEE

D O

O R

T Y

P E

S

D E

T A

IL

S

W E

S T

P O

IN

T

N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

J

U L Y

W D

S D

RTA SUBMISSION

L E

E B

A R

R A

C K

S

W D

S F

P N

1/2" = 1'-0"A1

WEST FACADE NEW RAMP AND ENTRANCE TO EQUIP CLEANING

1/2" = 1'-0"A7

EAST FACADE SUBBASEMENT STOREFRONT ENTRY DOORS

1/2" = 1'-0"D7

WEST FACADE MAIN ENTRY WOOD DOORS

1/2" = 1'-0"D3

SOUTH RAMP DOOR ELEVATION - 3

1/2" = 1'-0"D5

SOUTH RAMP DOOR ELEVATION - 1

1/2" = 1'-0"D1

NORTH RAMP DOOR ELEVATION

1/4" = 1'-0"F1

INTERIOR DOOR TYPES

EXISTING EXTERIOR WOOD DOORS & FRAMES:

1. ALL EXISTING EXTERIOR WOOD DOORS AT EXIT LEVEL TO RE REMOVED BEFORE GENERAL DEMO BEGINS AND PROTECTED.

2. REPAIR & REFINISH TO MATCH ORIGINAL FINISH, PREPARE FOR NEW HARDWARE.

3. AFTER DOORS ARE REMOVED PROTECT EXISTING FRAMES BEFORE GENERAL DEMO BEGINS, EXISTING PARTITION ADJACENT TO

EXISTING DOOR SUPPORTING THE EXISTING DOOR FRAME TO REMAIN.

4. REPAIR AND REFINISH EXISTING FRAME IN-PLACE.

5. EXTERIOR HISTORICAL FRAMES TO BE REPLACED TO MATCH EXISTING WHERE CONDITION IS NOT SUITABLE FOR REPAIR AND

REINSTALLATION.

1 2 42

SCALE: 1/2" = 1'-0"

02 4 8134

SCALE: 1/4" = 1'-0"

#4 REINF IN EA CORE

1" BACK-BEND @

MET DR FRAME

10 1/4"

/8

DR THK+3/16 VARIES DR THK +3/16

FILL CMU CORES SOLID

W/GROUT

MAS ANCHORS NOT

MORE THAN 18" FROM

TOP & BOT OF FRAME &

@ 32" OC MAX

J-BEAD

1/2" GYPSUM PLASTER

OR CERAMIC TILE ON

MORTAR. SEE PLANS.

1"1 1/2"

1/8" SEALANT

(CONTINUES AS 1/2"

CONTROL JOINT ABOVE

DOOR BETWEEN STUD WALL

AND MASONRY WALL

FILL JAMB SOLID

W/GROUT

CORRIDOR SIDE ROOM SIDE

1/2" TERRAZZO WALL BASE

#4 REINF IN EA CORE

MET DR FRAME

FILL CMU CORES SOLID

W/GROUT

MAS ANCHORS NOT

MORE THAN 18" FROM

TOP & BOT OF FRAME &

@ 32" OC MAX

PTD CMU

1/2" GYPSUM PLASTER

OR CERAMIC TILE ON

MORTAR. SEE PLANS.

J-BEAD

1" 1/2"

9 1/4"

1/8" SEALANT

(CONTINUES AS 1/2"

CONTROL JOINT ABOVE

DOOR BETWEEN STUD

WALL AND MASONRY WALL

FILL JAMB SOLID

W/GROUT

/8

ACOUSTICAL BATT

MET DOOR FRAME1"

2" VARIES 2"

9 3/4"

SEALANT EACH

SIDE, TYP.

CADET

ROOM SIDE

CORRIDOR

SIDE

1"

GYP BOARD CEILING

6" METAL STUD

FRAMING

MATCH CMU WALL ASSEMBLY ADJACENT

1 LAYER 5/8"

1 LAYER 1/2"

GYP BOARD

3 LAYERS 1/2"

GYP BOARD

@ SMOKE PARTITION UL

APPROVED 1/2HR. FIRE-

CAULK SEALANT EACH

SIDE, TYP.

EXISTING

STRUCTURAL

SLAB

CRIPPLE STUDS

20 GA STL RUNNER

MET DOOR HEAD FRAME

HEAD DETAIL

(SECT)

PTN AS SCHED

BOXED 3 5/8" 20 GA SSMA

362 S 137-33 STUDS

20 GA MET "U" STRAP @ 24" OC

SL EA SIDE

MET DOOR FRAME

ANCHORS @ JAMBS

JAMB DETAIL

(PLAN)

ACTUAL PTN THK

1/2" TYP

2" VARIES 2"

ACTUAL PTN THK +1"

/8

FIRE RATED PTN'S REQUIRE

1/2" PENETRATION OF GWB

INTO THE FRAME

CERAMIC TILE

WHERE INDICATED

O P

N G

S

IZ

E

#4 REINF IN EA CORE

1" BACK-BEND @

MET DR FRAME

7 3/4"

/8

DR THK+3/16 VARIES DR THK +3/16

FILL CMU CORES SOLID

W/GROUT

MAS ANCHORS NOT

MORE THAN 18" FROM

TOP & BOT OF FRAME &

@ 32" OC MAX

J-BEAD

1/2" GYPSUM PLASTER

1/2"1/2"

1/8" SEALANT

(CONTINUES AS 1/2" CONTROL

JOINT ABOVE DOOR BETWEEN

STUD WALL AND MASONRY WALL)

FILL JAMB SOLID

W/GROUT

#4 REINF IN EA CORE

1" BACK-BEND @

MET DR FRAME

7 1/4"

/8

DR THK+3/16 VARIES DR THK +3/16

FILL CMU CORES SOLID

W/GROUT

MAS ANCHORS NOT

MORE THAN 18" FROM

TOP & BOT OF FRAME &

@ 32" OC MAX

J-BEAD

1/2" GYPSUM PLASTER

1/2"1/2"

1/8" SEALANT

(CONTINUES AS 1/2"

CONTROL JOINT ABOVE

DOOR BETWEEN STUD WALL

AND…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .