This document outlines a federal contract opportunity for building repair work at the United States Military Academy. The U.S. Army Corps of Engineers, New York District intends to issue a solicitation to award a firm-fixed price contract to repair Building 740 at Lee Barracks and Building 738 at Sherman Barracks at the United States Military Academy in West Point, New York. The repairs to Building 740 will fully renovate the facility and supporting site work, upgrading building systems, interiors, and adding a Cadet Health Clinic. Optional work includes fully renovating Building 738 and supporting site work. The period of performance is approximately 1,034 calendar days from notice to proceed. The estimated value of the construction is between $100 million and $200 million. The solicitation is anticipated to be posted on August 6, 2021 on SAM.gov with proposals due approximately 30 days later.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FLOOR DRAIN WITH
WEEPS
AND MEMBRANE CLAMPS
EXIST. CONC. SLAB, WIDEN
OPENING AS REQ. FOR
INSTALLATION OF NEW
FLOOR DRAIN
INFILL VOID WITH MORTAR
WATERPROOFING
MEMBRANE
FLOOR TILE ON THIN
SET
EPOXY GROUT
TAPERED MORTAR BED
(SLOPE TO DRAIN)
3 5/8" MET STUD
WATERPROOFING
MEMBRANE
FLEXIBLE SEALANT
TERRAZZO SHOWER BASE
CMU PARTITION, SEE PLANS
X X X X X X X
FLOOR TILE ON THIN SET
EPOXY GROUT, TYP.
TAPERED MORTAR BED
(SLOPE TO DRAIN)
WATER PROOFING
MEMBRANE
FLEXIBLE SEALANT
AGAINST TERRAZZO PAN
INTEGRAL DRAIN WITH
REMOVABLE GRID STRAINER
EXISTING FLOOR SLAB
M
IN
FILL VOID WITH MORTAR
1/2" CEMENT BACKER BD.
1/2" CORIAN PANEL, TYP.
MORTAR SETTING BED
FOR BASE
SEE PLANS FOR FLOOR DRAIN LOCATIONS
REINFORCED 1 1/2"
STRUCTURAL CONC.
INFILL, TYP.
X X XX X X X X X X X X X XXXXXXXXX XXXXX XXXX X
1' - 8" 1' - 8"
40" x 40" SQUARE TOPPING SLAB TAPPERED (1/8" SLOPE) TO DRAIN
PLUMBING IN CHASE
CORIAN PANEL EDGE
BEYOND
PARTITION BEYOND
SHOWER STALL LOCKER ROOMCORRIDOR
XXX
3 5/8" MET STUD
WATERPROOFING
MEMBRANE
FLEXIBLE SEALANT
TERRAZZO SHOWER BASE
X X X
INTEGRAL DRAIN WITH
REMOVABLE GRID STRAINER
M
IN
FILL VOID WITH
MORTAR
1/2" CEMENT BACKER BD.
1/2" CORIAN PANEL, TYP.
MORTAR SETTING BED
FOR BASE
X X X X X XXX XXXXX
SHOWER STALL
XXX XX XXXX
SHOWER STALL SHOWER STALL
XX
EQ EQ
XX X X X X X
F O
T
TILE AS SCHEDULED
MORTAR
5/8" BACKER BOARD
3 5/8" CFMF
1/2" BACKER BOARD
1/2" SOLID
SURFACE AS
SCHEDULED
SHOWER CURTAIN
ROD ABV
F O
S
S H
O W
E R
D E
P T
H
TA-32TA-32
FLEXIBLE SEALANT
SHOWER
STALL
SHOWER
STALL
TERRAZZO SHOWER BASE BELOW
2 1/2"
WATERPROOFING
MEMBRANE
SS CORNER STRIP
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/22/2021 12:52:40 PM
A-580
LEE
IN
T
E R
IO
R
D E
T A
IL
S
C
A D
E T
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
3" = 1'-0"A1
TERRAZZO PAN DETAIL @ SHOWER AND BATHROOM FL
3" = 1'-0"D1
TERRAZZO PAN DETAIL @ SHOWER
3" = 1'-0"D6
PLAN DETAIL - SHOWER PARTITION
CONTRACTOR TO COMPLETE BATHROOM FLOOD TEST PRIOR TO
INSTALLATION OF SHOWER BASES.
SCALE: 3" = 1'-0"
1/21/4
BASEMENT
-11' - 0" x7
ALUM BASE SHOE
2 1/2"
/2
STL ANGLE.
SEE STRU
LAMINATED SAFETY GLASS
W/ DECORATIVE PATTERN
INTERLAYER
AL REVEAL
STAINLESS STEEL TRIM (SCHLUTER
RENO-DECO OR EQUAL)
TERRAZZO - SEE FINISH PLAN
J BEAD TRIM
BRUSHED SST
ANODIZED CONCEALED
HEAD CHANNEL
1"
FINISH CEILING AS SCHEDULED
ABOVE CEILING BLOCKING
AS REQUIRED
DIAGONAL CFMF STUD
CROSS BRACING AS
REQUIRED
CONTINUOUS CFMF BOX
HEADER ENTIRE LENGTH OF
GLASS WALL
SEALANT JOINT TO MATCH HEADER,
ALIGN WITH CHANNEL LEGS
SHIM AS REQ'D
1/4" TEMPERED GLASS
FRAMELESS GLASS
SLIDING WINDOW
(SEE SPEC)
DIAGONAL CFMF STUD
CROSS BRACING AS
REQUIRED
CONTINUOUS CFMF BOX
HEADER ENTIRE LENGTH OF
WINDOW
2 cm QS
TRANSACTION
SHELF ON 3/4" MDF
3"X3" SUPPORT ANGLE
ROUTED IN MDF
LAMINATE
/4
QS COUNTER ON RAKKS
BRACKET (OR EQUAL)
COLOR MATCH SILICONE
LAMINATED FR-MDF
PANELS ON METAL CLEATS
2 CM QS
TRANSACTION
SHELF ON 3/4" MDF
1/4" TEMPERED GLASS
FRAMELESS GLASS
SLIDING WINDOW
(SEE SPEC)
4" @ RECEPTION
9"
FIRE / SECURITY
SHUTTER
2"
3"X3" SUPPORT
ANGLE ROUTED
IN MDF
AL TRIM AT SLOT
PERIMETER
DIAGONAL CFMF STUD
CROSS BRACING AS
REQUIRED
CONTINUOUS CFMF BOX
HEADER ENTIRE LENGTH OF
GLASS WALL
QS COUNTER ON RAKKS
BRACKET (OR EQUAL)
/8
LAMINATE
/4
SECURITY MESH
COLOR MATCH SILICONE
PAINT EXPOSED STEEL
TRACK TO MATCH
ADJACENT SURFACE
SOFFIT
5"
SLIDING
TRANSACTION
WINDOW TRACK
RECESSED INTO
SILL, PROVIDE
KEYED LOCK
FIRE RATED MINERAL CORE WIDTH PER SHUTTER MFR.
1/4" TEMPERED GLASS
FRAMELESS GLASS
SLIDING WINDOW
(SEE SPEC)
DIAGONAL CFMF STUD
CROSS BRACING AS
REQUIRED
CONTINUOUS CFMF BOX
HEADER ENTIRE LENGTH OF
WINDOW
2 cm QS
TRANSACTION
SHELF ON 3/4" MDF
/4
4"
SSUR COUNTER ON RAKKS
BRACKET (OR EQUAL)
COLOR MATCH SILICONE
2 cm QS
TRANSACTION
SHELF ON 3/4" MDF
3"X3" SUPPORT ANGLE
ROUTED IN MDF
LAMINATE
/4
4"
1/4" TEMPERED GLASS
FRAMELESS GLASS
SLIDING WINDOW
(SEE SPEC)
DIAGONAL CFMF STUD
CROSS BRACING AS
REQUIRED
CONTINUOUS CFMF BOX
HEADER ENTIRE LENGTH OF
WINDOW
1/2" AL REVEAL
BASEMENT
-11' - 0"
LAMINATED SAFETY GLASS
W/ DECORATIVE PATTERN
INTERLAYER
SHIM AS REQ'D
SEALANT TO MATCH BASE SHOE
TERRAZZO - SEE FINISH PLAN
J BEAD TRIM
BRUSHED SST
ANODIZED CONCEALED
HEAD CHANNEL
FINISH CEILING AS SCHEDULED
ABOVE CEILING BLOCKING
AS REQUIRED
DIAGONAL CFMF STUD
CROSS BRACING AS
REQUIRED
CONTINUOUS CFMF BOX
HEADER ENTIRE LENGTH OF
GLASS WALL
SEALANT JOINT TO MATCH HEADER,
ALIGN WITH CHANNEL LEGS
SHIM AS REQ'D
ALUM BASE SHOE: ATTACH W/
CONCRETE ANCHORS 12" O.C., TYP.
1/4" CLEAR SILICONE BUTT
JOINT AT CMU WALL
ALUM BASE SHOE
LAMINATED SAFETY GLASS
WITH DECORATIVE
INTERLAYER
1/4" CLEAR SILICONE BUTT
JOINT, TYP
ALIGN SEAMS OF GL SHOE
W/ JOINT, TYP
ALUM BASE SHOE
LAMINATED SAFETY GLASS
WITH DECORATIVE
INTERLAYERBASEMENT
-11' - 0" x14
SCHED BASE
EXISTING CONCRETE BEAM
3/4" SS ON 3/4" MDF; SS3
CFMF
1' - 6 3/4"
/2
/2
PAINTED PLASTER
JAMB OF SHUTTER
RECESSED INTO WALL
(ONE SIDE)
W A
L L
B L
W
QS TRANSACTION TOP
PAINT EXPOSED JAMB TO
MATCH WALL @ PIER
MISC. METAL SUPPORTS
SECURITY MESH
QS COUNTER TOP
SLIDING TRANSACTION
WINDOW TRACK
RECESSED INTO SILL,
PROVIDE KEYED LOCK
EX. PIER
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
LEE
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/22/2021 12:53:07 PM
A-590
IN
T
E R
IO
R
D E
T A
IL
S
C
H C
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
D e s ig n e r
A C
C h e c k e r
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
3" = 1'-0"A8
SECT DET @ GWS-1
3" = 1'-0"A5
WINDOW TYPE N @ CHC RECEPTION
3" = 1'-0"A1
WINDOW TYPE M @ CHC PHARMACY
3" = 1'-0"E8
WINDOW TYPE K DETAIL
3" = 1'-0"E6
WINDOW TYPE H - CHC APPT CLERK
3" = 1'-0"A7
ALT SECT DET @ GWS-1
3" = 1'-0"E4
PLAN DETAIL - GSW1 AT CMU
3" = 1'-0"F4
PLAN DETAIL - GSW1 TYP JOINT
1 1/2" = 1'-0"E1
SECTION DETAIL - BENCH AT UPTURNED BEAM
SCALE: 3" = 1'-0"
1/21/4
SCALE: 1 1/2" = 1'-0"
1 1/2" = 1'-0"G4
FIRE SHUTTER JAMB DETAILS
GENERAL PARTITION NOTES:
1. AT PARTITIONS TO RECEIVE CERAMIC TILE AND SHOWER STALL ASSEMBLIES (INCLUDING
CEILING OF SHOWER STALL) PROVIDE TYPE X GLASS MAT WATER-RESISTANT GYPSUM
TILE BACKING BOARD
2. WATER-RESISTANT GYPSUM BACKING BOARD MUST BE USED AT CEILINGS IN TOILET
ROOMS (EXCLUDING SHOWER CEILINGS), LOCKER ROOMS, LAUNDRY ROOMS, AND
JANITORIAL ROOMS
3. SEE FIN SCHED FOR FIN SUCH AS CERAMIC TILE, GLAZED OR POLISHED CMU TYPE,
PANELING, PAINT, ETC.
4. STANDARD CMU MUST BE 8" (NOM) THK UNO. NON-STANDARD CMU THK ARE INDICATED AS
FOLLOWS:
5. ALL PARTITIONS ARE TO EXTEND TO EXISTING STRUCTURE ABOVE, AND SEAL TO
STRUCTURE PER PARTITION TYPE REQUIREMENTS.
6. SLAB BETWEEN BASEMENT AND FL.1 IS A REQUIRED 2HR OCCUPANCY SEPARATION AND
MUST BE MAINTAINED AT ALL PENETRATIONS, FIRE-STOP AS REQUIRED TO MAINTAIN
RATING AT THIS EXISTING STRUCTURAL SLAB.
7. FIRE RATED PTN'S ARE IDENTIFIED IN OVERALL PLANS BY KEY & POCHE AS FOLLOWS:
8. PROVIDE RATED PTD PLYWOOD IN TELECOM ROOM AS REQUIRED BY THE TELECOM
DRAWINGS. FIREPROOFING LABEL TO REMAIN EXPOSED. SEE TELECOM SPECIFICATIONS.
M4
PARTITIONS
NONRATED
1 HR FIRE RATED
2 HR FIRE RATED
(1/2 HR) CMU SMOKE PTN
M6
EXISTING CONC. SLAB ABV
RUNNER - MIN SSMA 362T 250-43
FOR STUDS FROM 12' TO 22' LONG
HEAD DETAIL
PLAN DETAIL
POWDER ACTUATED FASTENERS
8" OC STAGGERED 1" EMBED
ACOUSTIC SEALANT EACH
SIDE, TYP. UL-APPROVED
FIRE-CAULKING AT RATED
ASSEMBLIES
DETAIL @ FLR
SEAL AROUND PENETRATING
DEVICES W/ACOUS SL
5/8" TYPE X GWB EA SIDE.
5/8" ACOUSTICAL GWB EA SIDE @
(1) LAYER 5/8" TYPE X GWB ONE SIDE,
(2) LAYERS 5/8" GWB ONE SIDE @
1/32" LEAD LINING @
AT ALL BATHROOMS PROVIDE 5/8" TYPE X GLASS MAT
WATER-RESISTANT GYPSUM TILE BACKING BOARD3 1/2" SAFB (STC 40 INTENT) @ G4A
G4S
6" SAFB (STC 40 INTENT) @ G6A
3 1/2" SAFB (STC 50 INTENT) @ G4AA
3 1/2" SAFB (STC 50 INTENT) @ G4AA-L
6" SAFB (STC 50 INTENT) @ G6AA
6" SAFB (STC 50 INTENT) @ G6AA-L 3 5/8" SSMA 362 S 137-33 STUDS @ 16" OC,
OTHER STUDS INDICATED ON PLANS
G3 (2 1/2" STUD)
SCHED BASE
MET RUNNER
ACOUS SL EA SIDE
/4
1" CLEAR BETWEEN TOP OF
STUDS & RUNNER
1 1/2" X 2" 19 GA CLIP
1 1/2" COLD ROLLED CHANNEL BRIDGING
ATTACH CLIPS TO STUD &
BRIDGING W/FRAMING SCREWS
FLR
G6 (6" STUD)
SECURITY MESH SEE SPEC 09 29 00
G4S (SECURITY)
GXAA
GXAB
GXAA-L
AT LEAD LINED WALL:
• 1/32" LEAD SHEET
BONDED TO GWB
• LEAD PLUG @ FIXINGS
• 1/16" THICK LEAD STRIP
@ PNL JT
- NON-RATED - NOM 8"
SEE FULL HGT DET
FULL HGT CMU PTN CERTIFIED FOR FIRE
RATING:
-1 HR FIRE RATING - UL U905 - NOM 8"
-2 HR FIRE RATING - UL U905 - NOM 8"
-2 HR FIRE RATING - UL U906 - NOM 6"
ALL CMU PTN'S ARE FROM FLR TO
UNDERSIDE OF STR ABV
HORZ TRUSS TYPE MAS REINF 16"
OC ALL "M" WALL TYPES
C1
VERTICAL REINFORCING INFORMATION
1 M8
2 M8
M8
WALL THICKNESS (IN)
MAX WALL HEIGHT (FT)
VERT WALL REINF
6 8
10'
#4 @ 48" OC
16'
#5 @ 48" OC
- 1/2" GYPSUM PLASTER DIRECTLY APPLIED TO
FINISHED SIDE OF MASONRY WALL
- 1/2" GYPSUM PLASTER DIRECTLY APPLIED TO
BOTH SIDES OF MASONRY WALL
M4G - GLAZED AND/OR POLISHED CMU - NOM. 4"
(3 5/8") AT STAIRWELLS. SEE INTERIORS (I)
DRAWINGS FOR FINISH DESIGNATION
-1/2 HR FIRE RATING - SMOKE PARTITION - NOM 8"S M8
2 M6
STANDARD CMU SHALL BE 8" (NOM) THK
UNO. NON-STANDARD CMU THK ARE
INDICATED AS FOLLOWS:
M6
M8P
M8P
- NON-RATED - NOM 4"M4
M4
PROVIDE CONT BOND BM
W/ #5 CONT WITHIN 2
COURSES OF TOP OF WALL
& GROUT TOP COURSE AT
REINF LOC (TYP)
* NON RATED: PACK W/ MINERAL
WOOL INS W/ SL EA SIDE
* FIRE RATED: UL APPROVED
FIRE STOP SYS
MASONRY PARTITION TOP
ANCHOR 48" O.C. WITH
ISOLATION SLEEVE, EMBED INTO
SECOND COURSE/ BOND BEAM
ALIGN WITH VERT REINF
UNDERSIDE OF
CONC SLAB OR BM
1" MIN TO 1 1/2" MAX
DIM MAY VARY W/ UL
APPROVED SYS
FOR THK
SEE PLANS
CUT CMU AT TOP COURSE AS
REQUIRED
TOP SIDE OF
CONC SLAB
VINYL COVE BASE
DUCT
EGE OF SLAB OPENING
1 M6
S G3AS G3A
S G3P
2 G3A
PTN TYPE CONT BTWN
DOUBLE
ARROWHEADS
PTN CHANGES
TYPE WHERE
ARROWHEADS
MEET
M6
INDICATES PTN TYPE WHEN
TYPE IS CONSISTENT FOR
LENGTH OF WALL SEGMENT
2 M3PB
FIRE RATING
• NUMBER OF HOURS
• IF NO NUMBER PTN
IS NON-RATED
• S - SMOKE PTN
(1/2 HOUR)
STUD SIZE OR
FURRING/THICKNESS
MATERIAL
G - GWB STUD PTN
F - FURRING W/GWB
M - CMU
S - SHAFT WALL
T - TILE WALL
SPECIAL ATTRIBUTE
A - ACOUSTICAL
L - LEAD LINED
P - PLASTER
PB - PLASTER BOTH
SIDES OF WALL
G - GLAZED AND/OR
POLISHED CMU
LEAD THICKNESS
1/32" OF LEAD
NOTES:
1. FOR ALL FURRING TYPES GWB TO EXTEND TO
STRUCTURE ABV
2. FOR EXISTING EXTERIOR WALLS ISOLATE MET FURR FROM
CONC OR MASONRY WITH SPRAY-FOAM INSULATION
3. EXTEND ALL FURRING STUDS TO STRUCTURE ABV
4. ALL FURRING TYPES FXX-L TO HAVE 1/32" LEAD LINING
PLAN
PLAN
F4P
F4
F4A
F3
MET STUD BRACE @
4'-0" OC VERT
5/8" TYPE X GWB ON 3 5/8"
MET STUDS @ 1'-4" OC
SAFB @ F4A
POULTRY NETTING OR
EQUIVALENT AS REQUIRED
TO RETAIN INSULATION
3/4" FIRE RETARDANT
PLYWOOD SHEATHING
5/8" ABUSE RESISTANT GWB UNO.
TYPE X FIRE RATED GWB WHERE
REQUIRED FOR RATING
1/2" GYPSUM PLASTER (TWO-COAT)
MET STUDS @ 1'-4" OC
MET STUD BRACE @
4'-0" OC VERT
VARIES, SEE PLAN
AT ALL BATHROOMS PROVIDE 5/8"
TYPE X GLASS MAT WATER
RESISTANT GYPSUM TILE
BACKING BOARD
5/8" TYPE X GLASS MAT WATER
RESISTANT GYPSUM TILE BACKING
BOARD F1
HAT CHANNEL
F3P
F2A
F2A-L
PLAN
F6
F6-L
MET STUD BRACE @
4'-0" OC VERT
5/8" TYPE X GWB ON 6"
MET STUDS @ 1'-4" OC
PLAN @ WALL
PROVIDE FIRE RATED CABINET
WHERE SHOWN IN RATED WALL
CONSTRUCTION
CABINET FRAME
CABINET DOOR
/2
M A
X
FIRE EXTINGUISHER
TUB
MOUNTING SCREW
PLAN @ WALL
SECTION @ SLAB
UL APPROVED
2HR FIRESTOP
FIRESTOP ALL
PENETRATIONS
THROUGH RATED
CONSTRUCTION
OPENING AS REQ'D
LOCATE CJ 2'-0" FROM
"T" PTN JUNCTION
KEEP JT FREE
OF MORTAR
INTERRUPT HORZ TRUSS
TYPE REINF @ EJ
SHEAR KEY
3/8" JOINT W/ BACKER ROD & SL
(BOTH SIDES)
PROVIDE SHEAR KEY AT
PTN'S WHICH ARE NOM
6" WIDE AND WIDER
AT FIRE RATED PTN
PROVIDE FIRE STOP SYS
LOCATE CJ MIN 1'-0"
FROM ANY OPENINGS
EDGE OF SHAFT OPNG
HEAD DETAIL
PLAN DETAIL
FIRE & SMOKE SL
DETAIL @ FLR
SHAFT SIDE (UNFINISHED)
1" LINER PANEL
GWB CAT @ ELEVATOR SHAFT
ONLY, SCREW FIXED TO STUDS.
CANT NOT REQD @
PROJECTIONS OF 2" OR LESS
J RUNNER
RUNNER TRACK
FLR
5 1/4"
3 3/4"
MIN
@ 2 1/2" C-H STUDS
@ 4" C-H STUDS
ROOM SIDE (FINISHED)
2 1/2" C-H (212CH-34) MET
STUDS @ 2'-0" OC
4" C-H (400CH-34) MET STUDS @
2'-0" OC @ELEVATOR SHAFTS
2 LAYERS 5/8" TYPE X
FIRE RATED GWB
EDGE OF SHAFT OPNG
2 HR UL HW D 0603
2 HR UL DES U415
2 HR UL BW S 0016
SCHED BASE
FIRE & SMOKE SL
T-2 SCHEDULED TILE
MORTAR BED
3-COAT GYPSUM PLASTER
DIRECTLY APPLIED TO FINISHED
SIDE OF (E) STRUCTURE
NOTES:
1. EXPOSED EXISTING CONCRETE
STRUCTURE TO BE COATED IN 3/4"
PLASTER TO MAINTAIN 2HR RATING
& PROVIDE A FINISHED SURFACE.
WALL TILE ON THINSET
CEMENTITIOUS BOND
COAT
WATERPROOFING
MEMBRANE
T2
T1
SCALE: 1 1/2"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/22/2021 12:53:17 PM
A-600
LEE
P A
R T
IT
IO
N T
Y P
E S
D
E T
A
IL
S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
3" = 1'-0"A3
GWB PARTITION TYPES G4(A)
3" = 1'-0"A1
CMU PARTITION TYPES M
1 1/2" = 1'-0"E1
FULL HEIGHT CMU PARTITION BRACING @
CONC. STRUC. & CMU @ SLAB OPENING
3" = 1'-0"D8
PARTITION LEGEND
3" = 1'-0"D6
FURRING PARTITION TYPES F
1 1/2" = 1'-0"F6
FIRE EXTINGUISHER CABINET DETAIL
1 1/2" = 1'-0"D3
FIRESTOP DETAIL
3" = 1'-0"F3
CONTROL JOINT @ INT. MASONRY PARTITION
3" = 1'-0"A6
SHAFTWALL PARTITION TYPE 2S3 - 2 HR
RATED - FINISHED 1 SIDE
3" = 1'-0"F8
MISC. PARTITION TYPES
6" STUDS AT ATFP FRAMING
FOR EXTERIOR OPENINGS,
3 5/8" STUDS AT ALL OTHER
EXTERIOR WALL FURRING
CONDITIONS
METAL LATH
3/4" FRT PLYWOOD
1 LAYER 5/8" IMPACT
RESISTANT GYPSUM
WALLBOARD
7/16" GYPSUM
PLASTER
6" CFMF STUD
6" CFMF STUD
3-5/8" CFMF STUD
EXISTING STRUCTURE
EXTERIOR INTERIOR
CLOSED-CELL SPRAY
FOAM
INSULATION/AVB,
R-25 MINIMUM
(WALLS)
F6P
F4P
2" +/- THERMAL BREAK2" +/- THERMAL BREAK
LEAD LINED GWB
FULL HGT X 2" WIDE LEAD
STRIP AT JT OF LEAD LINED
PNLS SAME THK AS GWB
LEAD LINING
SHIMS @ INTERMEDIATE
STUDS
3/8" Ø LEAD PLUGS SAME
THK AS GWB LINING @ ALL
FIXINGS
ROOM SIDECORRIDOR SIDE
SHEET LEAD LINING SAME
THK AS GWB LEAD LINING
UTILITY BOX
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/22/2021 12:53:27 PM
A-601
LEE
P A
R T
IT
IO
N S
C H
E D
U L E
D
E T
A
IL
S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
PARTITION SCHEDULE
FIRE
RATING
WALL
TYPE DESCRIPTION WIDTH
FIRE
TEST
ASSEMBLY
CODE
STC
INTENT TOP OF WALL
HEAD
DETAIL
BASE
DETAIL TYPE COMMENTS
- F1 7/8" Furring w/ 5/8" GWB one side - Non Rated 1 1/2" - C1010145 - BTM OF SLB ABV - A3/A-600 -
- F2A 1 1/2" Z Furring w/ 5/8" GWB one side - Non Rated 2 1/4" - C1010145 - BTM OF SLB ABV - A3/A-600 -
- F2A-L 1 1/2" Z Furring w/ 5/8" GWB one side and 1/32" lead lining - Non Rated 2 1/4" - C1010145 - BTM OF SLB ABV - A3/A-600 -
- F3 2 1/2" stud w/ 5/8" GWB one side - Non Rated 3 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -
- F3P 2 1/2" stud w/ 7/16" Plaster one side - Non Rated 4 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -
- F4 3 5/8" stud w/ 5/8" GWB one side 4 1/2" - C1010145 BTM OF SLB ABV A3/A-600 A3/A-600 -
- F4 3 5/8" stud w/ 5/8" GWB one side - Non Rated 4 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -
- F4A 3 5/8" stud w/ 5/8" GWB one side w/ Acoustical Insulation - Non Rated 4 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -
- F4P 3 5/8" stud w/ 7/16" Plaster one side - Non Rated 5 1/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -
S F4P 3 5/8" stud w/ 7/16" Plaster one side - Smoke Rated 4 3/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -
- F6 6" stud w/ 5/8" GWB one side - Non Rated 6 3/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -
- F6-L 6" stud w/ 5/8" GWB one side and 1/32" lead lining - Non Rated 6 3/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -
- F6P 6" stud w/ 4" Spray Foam Insulation and 5/8" Plaster one side 9 3/4" - C1010145 - BTM OF SLB ABV A3/A-600 A3/A-600 -
- G4 3 5/8" stud w/ 5/8" GWB ea side - Non Rated 5" - C1010145 37 BTM OF SLB ABV A3/A-600 A3/A-600 -
1 G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - 1HR Rated 5" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -
1 G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - 1HR Rated 5 1/2" - C1010145 45 BTM OF SLB ABV A6/A-600 A6/A-600 -
2 G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - 2HR Rated 5" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -
- G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 5" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -
- G4A 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 5 1/2" - C1010145 45 BTM OF SLB ABV A6/A-600 A6/A-600 -
1 G4AA 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - 1 HR Rated 5" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -
- G4AA 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 5" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -
- G4AAL 3 5/8" stud w/ 5/8" GWB ea side w/ Acoustical Insulation and 1/32" lead lining - Non Rated 5" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -
1 G4S 3 5/8" stud w/ 5/8" GWB ea side w/ Security Mesh and Acoustical Insulation - 1HR Rated 5" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -
- G6 6" stud w/ 5/8" GWB ea side - Non Rated 7 1/4" - C1010145 37 BTM OF SLB ABV A3/A-600 A3/A-600 -
- G6A 6" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 7 1/4" - C1010145 40 BTM OF SLB ABV A3/A-600 A3/A-600 -
- G6A 6" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 8" - C1010145 45 BTM OF SLB ABV A3/A-600 A3/A-600 -
- G6AA 6" stud w/ 5/8" GWB ea side w/ Acoustical Insulation - Non Rated 7 1/4" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -
- G6AAL 6" stud w/ 5/8" GWB ea side w/ Acoustical Insulation and 1/32" lead lining - Non Rated 7 1/4" - C1010145 50 BTM OF SLB ABV A3/A-600 A3/A-600 -
- GWS-1 1" Interior Glass Wall - - - - - - CHC SCOPE
- M4P 4" (nom) CMU partition w/ 7/16" Plaster one side - Non Rated 4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
S M4P 4" (nom) CMU partition w/ 7/16" Plaster one side - Smoke Rated 4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
2 M6 6" (nom) CMU partition - 2HR Rated 5 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
1 M6P 6" (nom) CMU partition w/ 7/16" Plaster one side - 1HR Rated 6" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
2 M6P 6" (nom) CMU partition w/ 7/16" Plaster one side - 2HR Rated 6" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
- M6P 6" (nom) CMU partition w/ 7/16" Plaster one side - Non Rated 6" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
1 M6PB 6" (nom) CMU partition w/ 7/16" of Plaster both sides - 1HR Rated 6 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -
2 M6PB 6" (nom) CMU partition w/ 7/16" of Plaster both sides - 2HR Rated 6 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -
- M6PB 6" (nom) CMU partition w/ 7/16" of Plaster both sides - Non Rated 6 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -
S M6PB 6" (nom) CMU partition w/ 7/16" Plaster both sides - Smoke Rated 6 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -
2 M8 8" (nom) CMU partition - 2HR Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
- M8 8" (nom) CMU partition - Non Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
S M8 8" (nom) CMU partition - Smoke Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
- M8G 8" (nom) Glaze-Face CMU partition - 2HR Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
2 M8G 8" (nom) Structural Glaze-Face CMU partition - 2HR Rated 7 3/4" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 PLEASE SEE STRUCTURAL DRAWINGS
1 M8P 8" (nom) CMU partition w/ 7/16" Plaster one side - 1HR Rated 8" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
2 M8P 8" (nom) CMU partition w/ 7/16" Plaster one side - 2HR Rated 8" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
S M8P 8" (nom) CMU partition w/ 7/16" Plaster one side - Smoke Rated 8" - C1010120 - BTM OF SLB ABV E1/A-600 E1/A-600 -
S M8PB 8" (nom) CMU partition w/ 7/16" Plaster both side - Smoke Rated 8 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -
1 M8PB 8" (nom) CMU partition w/ 7/16" Plaster both sides - 1HR Rated 8 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -
2 M8PB 8" (nom) CMU partition w/ 7/16" Plaster both sides - 2HR Rated 8 1/2" - C1010120 50 BTM OF SLB ABV E1/A-600 E1/A-600 -
2 S3 2 1/2" CH stud w/ liner panel and 5/8" GWB - 2HR Rated 4 3/4" U415 C1010145 43 BTM OF SLB ABV A6/A-600 A6/A-600 -
1 S3 4" CH stud w/liner panel and 1 layers 5/8" GWB - 1HR Rated 4 3/4" U415 C1010145 43 BTM OF SLB ABV A6/A-600 A6/A-600 -
2 S3P 2 1/2" CH stud w/liner panel and 5/8" GWB, 7/16" Plaster one side - 2HR Rated 5 1/4" U415 C1010145 43 BTM OF SLB ABV A6/A-600 A6/A-600 -
2 S4 4" CH stud w/liner panel and 1 layers 5/8" GWB - 1HR Rated 6 1/4" U415 C1010145 43 BTM OF SLB ABV A6/A-600 A6/A-600 -
3" = 1'-0"A7
TYP FURRING DETAIL AT EXT WALL
SCALE: 3" = 1'-0"
1/21/4
3" = 1'-0"D7
LEAD LINED PARTITION - DETAILS
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/22/2021 12:53:39 PM
A-610
LEE
D O
O R
S C
H E
D U
L E
E
X T
E R
IO
R
S
U B
-B A
S E
M E
N T
B A
S E
M E
N T
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
DOOR SCHEDULE - SUBBASEMENT
ROUGH
OPENING
DOOR SIZE DOOR FRAME
FIRE
RATING SMOKE HW
ELEC
REMARKSNUMBER WIDTH
LEAF
A
LEAF
B HEIGHT TYPE MATL GLAZ
UNDER
CUT TYPE MATL GLAZ P S F
LB001.1 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 05 AL TG G4 -- -- 0 X 0002 -- -- -- ALUM. STOREFRONT GLASS DOOR
LB001.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 07 WD FR PB6 -- -- 90 0025 -- -- -- --
LB001.3 5' - 4" 5' - 0" 2' - 6" 2' - 6" 7' - 0" 01 WD PB6 -- -- 20 X 0050 -- -- -- --
LB001.4 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD PB6 -- -- 20 X 0026 -- -- -- --
LB001.5 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD PB6 -- -- 20 X 0026 -- -- -- --
LB001.6 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD PB6 -- -- 20 X 0016 -- -- -- --
LB002 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 05 AL TG G4 -- -- 0 X 0002 -- -- -- ALUM. STOREFRONT GLASS DOOR
LB003.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 03 WD FP G4 -- -- 20 X 0021 -- -- -- --
LB003.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0019 -- -- -- --
LB004 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LB005.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --
LB005.2 3' - 4" 3' - 0" 7' - 0" -- -- G4 -- -- 0 -- -- -- -- CASED OPENING
LB006 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LB007 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LB008 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --
LB009 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --
LB010.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0016 -- -- -- --
LB010.2 5' - 4" 5' - 0" 2' - 6" 2' - 6" 7' - 0" 01 HM G4 -- -- 20 X 0015 -- -- -- --
LCS01 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 60 0051 -- CR -- PEEPHOLE, INTERCOM W/ DOOR RELEASE
LCS02 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0048.1 -- CR -- --
LCS05 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LCS07 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LCS08 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LCS09 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0036 -- CR -- --
LCS10 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LCS11 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LE-S-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"
LE-S-2 4' - 4" 4' - 0" 4' - 0" 7' - 0"
LE-S-3 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 HM P6 -- -- 90 0058 -- -- -- --
LS0.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 02 WD FP G4 -- -- 20 X 0013 -- CR -- --
LS0.2 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 02 WD FP PB6 -- -- 90 0024 -- CR -- --
LS0.3 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0052 -- -- -- --
LS01.1 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 HM PB6 -- -- 90 0022 -- -- -- --
LS01.2 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" PB6 -- -- 90 0023 -- CR -- --
LS02 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" P6 -- -- 90 0049 -- CR -- --
LS03 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" G4 -- -- 90 0006 -- CR -- --
LS05 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" PB6 -- -- 20 X 0009 -- CR -- --
LS06 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0016 -- -- -- --
LS07 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0048 -- CR -- --
LS09 6' - 4" 6' - 0" 3' - 0" 3' - 0" 8' - 0" 05 AL TG -- -- -- 0 0045 P CR -- ALUM. STOREFRONT GLASS DOOR, AUTO OPENER
LS-S-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT9 -- -- 90 0057 -- -- -- EXISTING OPENING V.I.F.
LS-S-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT9 -- -- 90 0046 -- -- -- EXISTING OPENING V.I.F.
LS-S-3 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 HM P8 -- -- 90 0008 -- -- -- --
DOOR SCHEDULE - BASEMENT
ROUGH
OPENING
DOOR SIZE DOOR FRAME
FIRE
RATING SMOKE HW
ELEC
REMARKSNUMBER WIDTH
LEAF
A
LEAF
B HEIGHT TYPE MATL GLAZ
UNDER
CUT TYPE MATL GLAZ P S F
L001.1 7' - 4" 7' - 0" 3' - 6" 3' - 6" 7' - 0" 01 HM 3/4" G4 -- -- 60 0029 -- CR -- --
L001.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM G4 -- -- 60 0011 -- -- -- --
L001.3 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" G4 -- -- 90 0028 -- -- -- --
LC001 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LC01.1 4' - 4" 4' - 0" 4' - 0" 7' - 0" 02 WD FP G4 -- -- 20 X 0020 -- CR FA HOLD OPEN
LC01.2 4' - 4" 4' - 0" 4' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0020 -- CR FA HOLD OPEN
LC01.3 4' - 4" 4' - 0" 4' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0013 -- CR -- --
LC002 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LC003 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 20 X 0016 -- CR -- --
LC004 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM 3/4" P6 -- -- 60 0014 -- CR -- --
LC005 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LC006 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 20 X 0033 -- CR -- --
LC007 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LC008 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LC009 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 60 0016 -- -- -- --
LC011.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --
LC011.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LC012.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 03 WD FP G4 -- -- 20 X 0048.1 -- CR -- --
LC012.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0016 -- -- -- --
LC014 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LC015 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 WD G4 -- -- 20 X 0031 -- -- -- --
LC017 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LC018 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD G4 -- -- 20 X 0018 -- -- -- --
LC019 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LC020 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD 3/4" G4 -- -- 20 X 0010 -- -- -- --
LC021 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LC022 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LC023 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LC024 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LC025 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LC026 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0018 -- -- -- --
LC027 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0016 -- -- -- --
LC028 3' - 10" 3' - 6" 3' - 6" 7' - 0" 02 WD FP G4 -- -- 20 X 0018 -- -- -- --
LC029 4' - 4" 4' - 0" 4' - 0" 7' - 0" 02 WD FP G4 -- -- 20 X 0030 -- -- -- --
LC030.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC030.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC031 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC032.1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC032.2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC033 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC034 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC035 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC036 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC037 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC038 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC039 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0034 -- -- -- --
LC040 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 WD G4 -- -- 20 X 0012 -- -- -- --
LE-B-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"
LE-B-2 4' - 4" 4' - 0" 4' - 0" 7' - 0"
LS-B-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0027 -- CR -- EXISTING OPENING V.I.F.
LS-B-2.1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0027 -- CR -- EXISTING OPENING V.I.F.
LS-B-2.2 3' - 5" 3' - 2" 3' - 2" 4' - 0" SST -- -- -- 0 0054 -- -- FA STAIR GATE. SEE SHEET A-501
DOOR SCHEDULE - EXTERIOR
ROUGH
OPENING
DOOR SIZE DOOR FRAME
FIRE
RATING SMOKE HW
ELEC
REMARKSNUMBER WIDTH
LEAF
A
LEAF
B HEIGHT TYPE MATL GLAZ
UNDER
CUT TYPE MATL GLAZ P S F
EX01 10' - 7" 6' - 0" 3' - 0" 3' - 0" 8' - 0" 05 AL TG -- -- -- 0 0002.1 P CR -- EXTERIOR ALUM. STOREFRONT GLASS DOOR, AUTO
OPENER
EX02 4' - 0" 3' - 8" 3' - 8" 7' - 0" 01 WD EX2 -- -- 90 0003 -- -- -- RESTORE EXISTING WOOD DOOR. SEE SHEET A-614
EX03 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 WD EX2 -- -- 90 0001 -- -- -- RESTORE EXISTING WOOD DOOR. SEE SHEET A-614
EX04 6' - 0" 5' - 8" 2' - 10" 2' - 10" 7' - 0" 01 HM ECM1 -- -- 90 0004 -- CR -- INSULATED EXTERIOR STEEL DOOR, FACTORY
FINISHED. EXISTING OPENING V.I.F.
EX05 3' - 10" 3' - 6" 3' - 6" 7' - 0" 01 HM ECM1 -- -- 0 0056 -- -- -- SEE SHEET A-511
EX06 4' - 4" 4' - 0" 4' - 0" 7' - 0" 01 SST ECM2 -- -- 90 0005 -- -- -- EXTERIOR ACCESSIBLE INSULATED STEEL DOOR. SEE
SHEET A-614
EX103 10' - 0" 6' - 1" 7' - 6"
EX108 10' - 0" 6' - 1" 7' - 6"
FA01 3' - 8" 3' - 8" 7' - 6" 01 HM -- -- -- 0 -- -- -- -- --
EX1
EX1
RESTORE EXISTING WOOD DOOR. SEE SHEET A-614
RESTORE EXISTING WOOD DOOR. SEE SHEET A-614
DOOR FRAME NOTES:
1. FRAME TYPES "EX" - AN EXISTING FRAME TO REMAIN IN PLACE FOR REPAIR AND REFINISHING. SEE SHEET A-614.
2. ELEVATOR DOOR FRAMES BY ELEVATOR MANUFACTURER
3. DOOR FRAMES AT INTEGRAL ROOF SCREEN DOOR ASSEMBLIES ARE CUSTOM FABRICATED
4. ALL EXISTING ROUGH OPENINGS MUST BE V.I.F.
3' - 0"
3' - 0"
3' - 0"
3' - 0"
WD
WD
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/22/2021 12:53:53 PM
A-611
LEE
D O
O R
S C
H E
D U
L E
S
T
N
D
R D
T
H
T
H
R O
O F
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
DOOR SCHEDULE - FIRST FLOOR
ROUGH
OPENING
DOOR SIZE DOOR FRAME
FIRE
RATING SMOKE HW
ELEC
REMARKSNUMBER WIDTH
LEAF
A
LEAF
B HEIGHT TYPE MATL GLAZ
UNDER
CUT TYPE MATL GLAZ P S F
L101.1 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0048 -- CR -- --
L101.2 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD G4 -- -- 20 X 0012 -- -- -- --
L102 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" P8 -- -- 60 0017 -- CR -- --
L103 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 WD PB8 -- -- 90 0042 -- CR -- HOLD OPEN.
L104 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0044 -- -- -- --
L105 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --
L106 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --
L107 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0039 -- -- -- --
L108 6' - 4" 6' - 0" 3' - 0" 3' - 0" 7' - 0" 01 WD PB8 -- -- 90 0042 -- CR -- HOLD OPEN.
L109.2 4' - 4" 4' - 0" 4' - 0" 7' - 0" 02 HM FP PB8 -- -- 20 X 0035 -- CR -- --
L110.1 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 60 0036 -- CR -- --
L110.2 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 20 0037 -- CR -- --
L111.1 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0038 -- CR -- --
L112 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 HM PB8 -- -- 90 0047 -- CR -- --
L113 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0043 -- CR -- --
L114.1 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0036 -- CR -- --
L114.2 4' - 4" 4' - 0" 4' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0036 -- CR -- --
LE-1-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"
LS-1-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
LS-1-2.1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
LS-1-2.2 3' - 5" 3' - 2" 3' - 2" 4' - 0" SST -- -- -- 0 0054 -- -- FA STAIR GATE. SEE SHEET A-501
DOOR SCHEDULE - SECOND FLOOR
ROUGH
OPENING
DOOR SIZE DOOR FRAME
FIRE
RATING SMOKE HW
ELEC
REMARKSNUMBER WIDTH
LEAF
A
LEAF
B HEIGHT TYPE MATL GLAZ
UNDER
CUT TYPE MATL GLAZ P S F
L201 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0017 -- CR -- --
L202 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0019 -- -- -- --
L203 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0018 -- -- -- --
L204 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0044 -- -- -- --
L205.1 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0048 -- CR -- --
L205.2 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0048 -- CR -- --
L206 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB6 -- -- 90 0017 -- CR -- --
L207 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0010 -- -- -- --
L208 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --
L2001 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2002 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2003 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2004 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2005 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2006 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2007 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2008 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2009 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2010 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2011 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2012 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2013 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2014 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L2015 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
LE-2-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"
LS-2-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
LS-2-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
DOOR SCHEDULE - THIRD FLOOR
ROUGH
OPENING
DOOR SIZE DOOR FRAME
FIRE
RATING SMOKE HW
ELEC
REMARKSNUMBER WIDTH
LEAF
A
LEAF
B HEIGHT TYPE MATL GLAZ
UNDER
CUT TYPE MATL GLAZ P S F
L301 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0017 -- CR -- --
L302 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0019 -- -- -- --
L303 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0018 -- -- -- --
L304 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0044 -- -- -- --
L305.1 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD PB8 -- -- 20 X 0048 -- CR -- --
L305.2 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0016 -- -- -- --
L306 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB6 -- -- 90 0017 -- CR -- --
L307 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0039 -- -- -- --
L308 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --
L3001 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3002 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3003 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3004 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3005 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3006 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3007 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3008 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3009 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3010 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3011 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3012 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3013 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3014 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3015 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L3016 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
LE-3-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"
LS-3-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
LS-3-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
DOOR SCHEDULE - FOURTH FLOOR
ROUGH
OPENING
DOOR SIZE DOOR FRAME
FIRE
RATING SMOKE HW
ELEC
REMARKSNUMBER WIDTH
LEAF
A
LEAF
B HEIGHT TYPE MATL GLAZ
UNDER
CUT TYPE MATL GLAZ P S F
L401 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0017 -- CR -- --
L402 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0019 -- -- -- --
L403 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0018 -- -- -- --
L404 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0044 -- -- -- --
L406 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB6 -- -- 90 0017 -- CR -- --
L407 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0039 -- -- -- --
L408 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --
L4001 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4002 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4003 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4004 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4005 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4006 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4007 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0032 -- CR -- --
L4008 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4009 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4010 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4011 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4012 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4013 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4014 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4015 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4016 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4017 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4018 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L4019 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
LE-4-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"
LS-4-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
LS-4-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
DOOR SCHEDULE- FIFTH FLOOR
ROUGH
OPENING
DOOR SIZE DOOR FRAME
FIRE
RATING SMOKE HW
ELEC
REMARKSNUMBER WIDTH
LEAF
A
LEAF
B HEIGHT TYPE MATL GLAZ
UNDER
CUT TYPE MATL GLAZ P S F
L501 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 60 0017 -- CR -- --
L502 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0019 -- -- -- --
L503 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0018 -- -- -- --
L504 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0044 -- -- -- --
L506 3' - 4" 3' - 0" 3' - 0" 6' - 10" 01 WD 3/4" PB6 -- -- 90 0017 -- CR -- --
L507 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD 3/4" PB8 -- -- 20 X 0039 -- -- -- --
L508 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0018 -- -- -- --
L5001 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5002 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5003 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5004 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5005 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5006 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5007 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB6 -- -- 20 X 0032 -- CR -- --
L5008 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5009 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5010 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5011 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5012 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5013 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5014 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5015 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5016 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5017 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5018 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
L5019 3' - 2" 2' - 10" 2' - 10" 6' - 10" 01 WD PB8 -- -- 20 X 0032 -- CR -- --
LE-5-1 4' - 4" 4' - 0" 4' - 0" 7' - 0"
LS-5-1 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
LS-5-2 3' - 10" 3' - 6" 3' - 6" 6' - 10" 02 HM FR ECT8 -- -- 90 0007 -- -- -- HOLD OPEN. EXISTING OPENING V.I.F.
DOOR SCHEDULE- ROOF LEVEL
ROUGH
OPENING
DOOR SIZE DOOR FRAME
FIRE
RATING SMOKE HW
ELEC
REMARKSNUMBER WIDTH
LEAF
A
LEAF
B HEIGHT TYPE MATL GLAZ
UNDER
CUT TYPE MATL GLAZ P S F
L601 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM ECM1 -- -- 90 0041 -- CR -- INSULATED EXTERIOR STEEL DOOR, FACTORY FINISHED
LR-1 6' - 4" 6' - 0" 3' - 0" 3' - 0" 11' - 0" 01 STL -- -- -- 0 0053 -- -- -- ROOF SCREEN DOOR ASSEMBLY, SEE A-512 / E1
LR-2 6' - 4" 6' - 0" 3' - 0" 3' - 0" 11' - 0" 01 STL -- -- -- 0 0053 -- -- -- ROOF SCREEN DOOR ASSEMBLY, SEE A-512 / E1
LR-3 6' - 4" 6' - 0" 3' - 0" 3' - 0" 11' - 0" 01 STL -- -- -- 0 0053 -- -- -- ROOF SCREEN DOOR ASSEMBLY, SEE A-512 / E1
LS-6-1 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM ECM1 -- -- 90 0040 -- CR -- INSULATED EXTERIOR STEEL DOOR, FACTORY FINISHED.
EXISTING OPENING V.I.F. SEE SHEET A-520
LS-6-2 3' - 4" 3' - 0" 3' - 0" 7' - 0" 01 HM ECM1 -- -- 90 0040 -- CR -- INSULATED EXTERIOR STEEL DOOR, FACTORY FINISHED.
EXISTING OPENING V.I.F. SEE SHEET A-520
DOOR FRAME NOTES:
1. FRAME TYPES "EX" - AN EXISTING FRAME TO REMAIN IN PLACE FOR REPAIR AND REFINISHING. SEE SHEET A-614.
2. ELEVATOR DOOR FRAMES BY ELEVATOR MANUFACTURER
3. DOOR FRAMES AT INTEGRAL ROOF SCREEN DOOR ASSEMBLIES ARE CUSTOM FABRICATED
4. ALL EXISTING ROUGH OPENINGS MUST BE V.I.F.
FIRST FLOOR
0" x2x3 3"
ROUGH OPENING
4' - 4"3"
6' - 6"22' - 0"
INSULATED
FACTORY-FINISHED
EXTERIOR STEEL
DOOR
NEW CAST-IN-PLACE
CONCRETE LANDING
NEW CAST-IN-PLACE
CONCRETE RAMP
EXTERIOR GUARD
AND HANDRAIL,
PAINTED BLACK
A3
A-614
D3
A-614
R4
4' - 0"
BASEMENT
-11' - 0"
SUB-BASEMENT
-22' - 0" x7 x8 V.I.F.
10' - 7"
2" 1' - 11 1/2" 2" 6' - 0" 2" 1' - 11 1/2" 2"
V .I
.F
6' - 0"
ALUMINUM
STOREFRONT AND
ENTRANCE DOORS
NEW CAST-IN-PLACE
CONCRETE STAIRS &
LANDING
MASONRY JOINT
CLEANING AND
RESTORATION
A7
A-615
D3
A-616
B3
A-616
A3
A-616
A1
A-616
B1
A-616
D1
A-616
D9
A-616
E9
A-616 6" SQUARE BOLLARD
WITH ADA PUSH
BUTTON
EXTERIOR SINGLE
PIPE HANDRAIL,
PAINTED BLACK
EQEQ EQEQ
FIRST FLOOR
0"
1' - 8"
3 1/2"
LEAF B
3' - 0"1"
LEAF A
3' - 0"
3 1/2"
1' - 8"
RESTORE HISTORIC
WOOD ENTRANCE
DOORS
REPAIR / RESTORE
WINDOWS IN
HISTORIC WOOD
ENTRANCE DOORS
RESTORE AND
REINSTALL BRONZE
RAILINGS
V .I
.F
V
IF6
REPAIR EXISTING
CONCRETE SURFACE
REPLACE REMOVABLE
MULLION (BEYOND)
EXISTING DOOR TRIM
TO BE REMOVED,
REFINISHED, AND
REINSTALLED
V.I.F.
10' - 0"
EXISTING STONE
LANDING TO REMAIN.
REPOINT JOINTS
6' - 1"
C6
A-614
EX04
5' - 8"
INSULATED
FACTORY-FINISHED
EXTERIOR STEEL
DOOR
V.I.F.
6' - 0"
V .I
.F
E3
A-614
7 1/2" 1 1/2" 7 1/2"
6' - 0"
V.I.F.
6' - 4"
V .I .F
EX03
A6
A-614
SIM
BASEMENT
-11' - 0"
7 1/2" 1 1/2" 7 1/2"
3' - 8"
RESTORE HISTORIC
WOOD ENTRANCE
DOORS
E1
A-590
V.I.F.
4' - 0"
V .I
.F
A6
A-614
SIM
1 2
WIDTH
LEAF A LEAF B
9" 3"
ALL FRAMES - HM, (SEE PARTITION TYPE TAGGED AT EACH DOOR FRAME)
GWB
GWB W/ PLASTER (BOTH SIDES)
GWB W/ PLASTER (ONE SIDE)
MASONRY W/ PLASTER (BOTH SIDES)
MASONRY W/ PLASTER (ONE SIDE)
(CERAMIC TILE AT BATHROOMS TO ABUT FRAME BACK-BEND)
6" 2'-0" 6"
GLAZING REQUIREMENTS:
1. ALL INTERIOR GLAZING MUST BE TEMPERED SAFETY GLASS
(TSG) UNO
2. GLAZING IN RATED DOORS TO BE FIRE PROTECTIVE
LAMINATED GLASS (FP)
9" 6"
1. DOOR SCHEDULE IS PART OF AN OVERALL DOOR SYSTEM; COORDINATE DOOR SCHEDULE WITH HARDWARE SCHEDULE, ACCESS
CONTROL, SECURITY, AND ELECTRICAL. PROVIDE COMPLETE AND OPERABLE SYSTEM.
2. COORDINATE CARD READER AND SECURITY WITH ALL DISCIPLINES. PROVIDE ALL CARD READERS INDICATED ON CONTRACT DOCUMENTS AND PROVIDE ALL NECESSARY COMPONENTS AND INFRASTRUCTURE FOR A COMPLETE AND OPERABLE SYSTEM
INTEGRATED INTO CAMPUS CONTROL SYSTEM.
3. COORDINATE ALL ELECTRIFIED AND LOW-VOLTAGE DEVICES WITH ALL DISCIPLINES. PROVIDE ALL NECESSARY POWER, COMPONENTS AND INFRASTRUCTURE FOR A COMPLETE AND OPERABLE SYSTEM.
4. WHERE DOORS HAVE LOUVERS REFERENCE MECHANICAL FOR CFM REQUIREMENTS
5. WHERE RATED DOORS HAVE VISION PANELS, VISION PANELS TO HAVE RATING TO MATCH DOOR AND BE PROVIDED WITH LABEL
INDICATING COMPLIANCE.
6. UNDERCUT BOTTOM OF RATED DOORS 3/4" MAXIMUM PER NFPA 80, 4.8.4.1
7. DOORS IN 1/2HR. SMOKE PARTITIONS TO BE 20 MINUTE RATED.
8. ALL DOORS TO BE EXTRA HEAVY DUTY DOORS.
GENERAL DOOR NOTES:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/22/2021 12:54:10 PM
A-612
LEE
D O
O R
T Y
P E
S
D E
T A
IL
S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/2" = 1'-0"A1
WEST FACADE NEW RAMP AND ENTRANCE TO EQUIP CLEANING
1/2" = 1'-0"A7
EAST FACADE SUBBASEMENT STOREFRONT ENTRY DOORS
1/2" = 1'-0"D7
WEST FACADE MAIN ENTRY WOOD DOORS
1/2" = 1'-0"D3
SOUTH RAMP DOOR ELEVATION - 3
1/2" = 1'-0"D5
SOUTH RAMP DOOR ELEVATION - 1
1/2" = 1'-0"D1
NORTH RAMP DOOR ELEVATION
1/4" = 1'-0"F1
INTERIOR DOOR TYPES
EXISTING EXTERIOR WOOD DOORS & FRAMES:
1. ALL EXISTING EXTERIOR WOOD DOORS AT EXIT LEVEL TO RE REMOVED BEFORE GENERAL DEMO BEGINS AND PROTECTED.
2. REPAIR & REFINISH TO MATCH ORIGINAL FINISH, PREPARE FOR NEW HARDWARE.
3. AFTER DOORS ARE REMOVED PROTECT EXISTING FRAMES BEFORE GENERAL DEMO BEGINS, EXISTING PARTITION ADJACENT TO
EXISTING DOOR SUPPORTING THE EXISTING DOOR FRAME TO REMAIN.
4. REPAIR AND REFINISH EXISTING FRAME IN-PLACE.
5. EXTERIOR HISTORICAL FRAMES TO BE REPLACED TO MATCH EXISTING WHERE CONDITION IS NOT SUITABLE FOR REPAIR AND
REINSTALLATION.
1 2 42
SCALE: 1/2" = 1'-0"
02 4 8134
SCALE: 1/4" = 1'-0"
#4 REINF IN EA CORE
1" BACK-BEND @
MET DR FRAME
10 1/4"
/8
DR THK+3/16 VARIES DR THK +3/16
FILL CMU CORES SOLID
W/GROUT
MAS ANCHORS NOT
MORE THAN 18" FROM
TOP & BOT OF FRAME &
@ 32" OC MAX
J-BEAD
1/2" GYPSUM PLASTER
OR CERAMIC TILE ON
MORTAR. SEE PLANS.
1"1 1/2"
1/8" SEALANT
(CONTINUES AS 1/2"
CONTROL JOINT ABOVE
DOOR BETWEEN STUD WALL
AND MASONRY WALL
FILL JAMB SOLID
W/GROUT
CORRIDOR SIDE ROOM SIDE
1/2" TERRAZZO WALL BASE
#4 REINF IN EA CORE
MET DR FRAME
FILL CMU CORES SOLID
W/GROUT
MAS ANCHORS NOT
MORE THAN 18" FROM
TOP & BOT OF FRAME &
@ 32" OC MAX
PTD CMU
1/2" GYPSUM PLASTER
OR CERAMIC TILE ON
MORTAR. SEE PLANS.
J-BEAD
1" 1/2"
9 1/4"
1/8" SEALANT
(CONTINUES AS 1/2"
CONTROL JOINT ABOVE
DOOR BETWEEN STUD
WALL AND MASONRY WALL
FILL JAMB SOLID
W/GROUT
/8
ACOUSTICAL BATT
MET DOOR FRAME1"
2" VARIES 2"
9 3/4"
SEALANT EACH
SIDE, TYP.
CADET
ROOM SIDE
CORRIDOR
SIDE
1"
GYP BOARD CEILING
6" METAL STUD
FRAMING
MATCH CMU WALL ASSEMBLY ADJACENT
1 LAYER 5/8"
1 LAYER 1/2"
GYP BOARD
3 LAYERS 1/2"
GYP BOARD
@ SMOKE PARTITION UL
APPROVED 1/2HR. FIRE-
CAULK SEALANT EACH
SIDE, TYP.
EXISTING
STRUCTURAL
SLAB
CRIPPLE STUDS
20 GA STL RUNNER
MET DOOR HEAD FRAME
HEAD DETAIL
(SECT)
PTN AS SCHED
BOXED 3 5/8" 20 GA SSMA
362 S 137-33 STUDS
20 GA MET "U" STRAP @ 24" OC
SL EA SIDE
MET DOOR FRAME
ANCHORS @ JAMBS
JAMB DETAIL
(PLAN)
ACTUAL PTN THK
1/2" TYP
2" VARIES 2"
ACTUAL PTN THK +1"
/8
FIRE RATED PTN'S REQUIRE
1/2" PENETRATION OF GWB
INTO THE FRAME
CERAMIC TILE
WHERE INDICATED
O P
N G
S
IZ
E
#4 REINF IN EA CORE
1" BACK-BEND @
MET DR FRAME
7 3/4"
/8
DR THK+3/16 VARIES DR THK +3/16
FILL CMU CORES SOLID
W/GROUT
MAS ANCHORS NOT
MORE THAN 18" FROM
TOP & BOT OF FRAME &
@ 32" OC MAX
J-BEAD
1/2" GYPSUM PLASTER
1/2"1/2"
1/8" SEALANT
(CONTINUES AS 1/2" CONTROL
JOINT ABOVE DOOR BETWEEN
STUD WALL AND MASONRY WALL)
FILL JAMB SOLID
W/GROUT
#4 REINF IN EA CORE
1" BACK-BEND @
MET DR FRAME
7 1/4"
/8
DR THK+3/16 VARIES DR THK +3/16
FILL CMU CORES SOLID
W/GROUT
MAS ANCHORS NOT
MORE THAN 18" FROM
TOP & BOT OF FRAME &
@ 32" OC MAX
J-BEAD
1/2" GYPSUM PLASTER
1/2"1/2"
1/8" SEALANT
(CONTINUES AS 1/2"
CONTROL JOINT ABOVE
DOOR BETWEEN STUD WALL
AND…