RTA Drawings Lee Vol 1_Part3.pdf
PDF 7 MB Posted
- Solicitation number
- W912DS21B0004
About this file
This document provides details for a construction project solicitation for repair work at two buildings on the United States Military Academy campus. The solicitation will include repair of Building 740, Lee Barracks, and repair of Building 738, Sherman Barracks, along with associated site work. Building 740 repairs will include interior renovations, hazardous material abatement, mechanical and electrical system replacements, and addition of a Cadet Health Clinic. Repairs to Building 738 are also outlined. The period of performance is estimated at 1034 calendar days. The NAICS code is 236220 and total project cost is estimated between $100-200 million. The solicitation is expected to be posted on August 6, 2021 on SAM.gov with proposals due approximately 30 days later.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEGEND
THIS ITEM IS PART OF THE CADET HEALTH
CLINIC SCOPE OF WORK.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:41:25 PM
I-300B
LEE
B A
S E
M E
N T
S
IG
N A
G E
S C
H E
D U
L E
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
STANDARD SIGNAGE SCHEDULE - BASEMENT
Sign Code Sign Type Room Number Room Name Message Count Comments
S-B-06b P LS-S-2 STAIR 2 - 1
S-B-06c M LS-S-2 STAIR 2 - 1
S-B-06d K LS-S-2 STAIR 2 - 1
S-B-20b O LS-B-1 STAIR 1 - 1
S-B-20c M LS-B-1 STAIR 1 - 1
S-B-20d K LS-B-1 STAIR 1 - 1
Grand total 6
CHC SIGNAGE SCHEDULE - BASEMENT
Sign Code Sign Type Room Number Room Name Message Count Comments
S-B-01 PR-1 LC018 STAFF LOUNGE LC018 / STAFF LOUNGE 1
S-B-02 10 LC019 TBI RESEARCH ANALYST LC019 / TBI RESEARCH ANALYST 1
S-B-03a PR-1 L001a MECHANICAL ROOM L001a / MECHANICAL ROOM 1
S-B-03b PR-1 L001a MECHANICAL ROOM L001a / MECHANICAL ROOM 1
S-B-04 PR-1 L001b ELEVATOR MACHINE ROOM L001b / ELEVATOR MACHINE ROOM 1
S-B-05a S-2 LE-B-1 ELEVATOR 1 - 1
S-B-05b EP-1 LE-B-1 ELEVATOR 1 - 1 COORDINATE MAP IMAGE WITH LEVEL
S-B-06a SF-1 LS-S-2 STAIR 2 STAIR 2 1
S-B-07 TF-HC LC017 SPECIMEN TOILET - 1
S-B-08 PR-1 LC015 BLOOD DRAW / LABORATORY LC015 / BLOOD DRAW / LABORATORY 1
S-B-09 R-DM LC01d WAITING ROOM - 1
S-B-10 TF-HC LC014 TOILET - TLTU1 1
S-B-11 PR-1 LC012 APPOINTMENT CLERK /
RECEPTION
LC012 / APPOINTMENT CLERK / RECEPION 1
S-B-12 PR-1 LC12c COPY/SUPPLY ROOM LC12c / SUPPLY ROOM 1
S-B-13a FDS-1 LC01 WAITING ROOM - 1
S-B-13b FDS-1 LC01 WAITING ROOM - 1
S-B-14 TF-HC SLC011b TOILET - TLTU1 - 1
S-B-15 PR-1 LC011a ISOLATION EXRG LC011a / ISOLATION EXRG 1
S-B-16a PR-1 LC030 SCREENING / TRIAGE ROOM LC030 / SCREENING / TRIAGE ROOM 1
S-B-16b PR-1 LC030 SCREENING / TRIAGE ROOM LC030 / SCREENING / TRIAGE ROOM 1
S-B-17a PR-1 LC032 SCREENING / TRIAGE ROOM LC032 / SCREENING / TRIAGE ROOM 1
S-B-17b PR-1 LC032 SCREENING / TRIAGE ROOM LC032 / SCREENING / TRIAGE ROOM 1
S-B-18 PR-1 LC009 SOILED LINEN - USCL1 LC009 / SOILED LINEN ROOM 1
S-B-19 PR-1 LC008 CONSULT (BH/NUTRITION) LC008 / BH/NUTRITION CONSULT 1
S-B-20a SF-1 LS-B-1 STAIR 1 STAIR 1 1
S-B-21 PR-1 LC004 ELECTRICAL LC004 / ELECTRICAL 1
S-B-22 PR-1 LC001 TEAM ROOM 3-4 LC001 / TEAM ROOM 3-4 1
S-B-23 TF-HC LC002 STAFF TOILET - 1
S-B-24 PR-1 LC003 EQUIPMENT STORAGE LC003 / EQUIPMENT STORAGE 1
S-B-25 PR-1 LC005 TEAM ROOM 2-1 LC005 / TEAM ROOM 2-1 1
S-B-27 PR-1 LC006 CLEAN - UCCL1 LC006 / CLEAN LINEN ROOM 1
S-B-28 TF-HC LC007 PATIENT TOILET - 1
S-B-29 PR-1 LC040 TEAM ROOM 1 LC040 / TEAM ROOM 1 1
S-B-30 PR-1 LC038 EXAM ROOM LC038 / EXAM ROOM 6 1
S-B-31 PR-1 LC039 EXAM ROOM LC039 / EXAM ROOM 7 1
S-B-32 PR-1 LC037 EXAM ROOM LC037 / EXAM ROOM 5 1
S-B-33 PR-1 LC036 EXAM ROOM LC036 / EXAM ROOM 4 1
S-B-34 PR-1 LC035 EXAM ROOM LC035 / EXAM ROOM 3 1
S-B-35 PR-1 LC034 SPECIALTY ROOM LC034 / SPECIALTY ROOM 1
S-B-36 PR-1 LC033 EXAM ROOM LC033 / EXAM ROOM 2 1
S-B-37 PR-1 LC031 EXAM ROOM LC031 / EXAM ROOM 1 1
S-B-38a DR-1 LE-B-2 ELEVATOR 2 - 1
S-B-38b S-2 LE-B-2 ELEVATOR 2 - 1
S-B-38c EP-1 LE-B-2 ELEVATOR 2 - 1 COORDINATE MAP IMAGE WITH LEVEL
S-B-39 PR-1 LC029 TREATMENT/IMMUNIZATION LC029 / TREATMENT / IMMUNIZATIONS 1
S-B-40 PR-1 LC028a NURSE STATION LC028a / NURSE STATION 1
S-B-41 PR-1 LC027 EVS JANC1 LC027 / EVS JANITOR CLOSET 1
S-B-42 CR-1 LC026 CONFERENCE ROOM LC026 / CONFERENCE ROOM 1
S-B-43 10 LC025 CARE COORDINATOR OFFICE LC025 / CARE COORDINATOR OFFICE / TBD 1
S-B-45 10 LC024 OIC/CHIEF OFFICE LC024 / OIC / CHIEF OFFICE / TBD 1
S-B-46 10 LC023 NCOIC/CNOC OFFICE LC023 / NCOIC / CNOC OFFICE / TBD 1
S-B-47 10 LC022 CADET SURGEON OFFICE LC022 / CADET SURGEON OFFICE / TBD 1
S-B-48 10 LC021 OFFICE CARE COORDINATOR LC021 / OFFICE CARE COORDINATOR 1
S-B-49 TF-HC LC020 STAFF TOILET - 1
S-B-50 FDS-1 LC01 WAITING ROOM - 1
Grand total 55
FEC
N
MECHANICAL
L001a
RECEPTION
LC012a
APPOINTMENT
CLERK
LC012b
WAITING ROOM
LC01d
ELEVATOR 2
LE-B-2
TREATMENT/IMMUNIZATION
- TRGM1/OPIR1
LC029
NURSE STATION -
NSTA1
LC028a
COPY SUPPLY
RPR01
LC12c
OFFICE NCOIC /
CNOC - OFA05
LC023
OBSERVATION /
HYDRATION -
OOHR1
LC028b
CHC STAIR 4
LS-B-4
WAITING
ANCILLARY
SERVICES
LC01c
CIRCULATION
LC03
SPECIMEN TOILET
- TLTU1
LC017
BLOOD DRAW -
LBVP1
LC015a
STAIR 2
LS-B-2
ELEV. 1
LE-B-1
STAFF LOUNGE -
SL001
LC018
STAFF TOILET -
TLTU1
LC020
OFFICE TBI
RESEARCH
ANALYST - OFA05
LC019
OFFICE CARE
COORDINATOR-
OFA04
LC025
OFFICE OIC/CHIEF
- OFA04
LC024
CONFERENCE
ROOM - CRA01
LC026
OFFICE CARE
COORDINATOR -
OFA04
LC021
LABORATORY -
LBPC1
LC015b
TOILET
TLTU1
LC014
CADET SURGEON
- OFA04
LC022
WHEELCHAIR
ALCOVE - SRLW1
LC013
KIOSK
LC01b
/A1 I-200BA /A1 I-200BB
EVS
JANC1
LC027
AED -
RCA01
LC016
ELEVATOR
MACHINE ROOM
L001b
S-B-02
S-B-01
S-B-03a S-B-04
S-B-10
S-B-03b
S-B-12
S-B-11
S-B-08
S-B-40S-B-41
S-B-07S-B-06aS-B-05b
S-B-43
S-B-46
S-B-45
S-B-47
S-B-48
S-B-49
S-B-39
S-B-38c
S-B-42
S-B-38a
ROOF ACCESS
STAIR 3
LS-B-3
DOWN TO FLOOR
SB TO EXIT
S-B-05a
S-B-38b
S-B-13b
S-B-06b
S-B-06c
S-B-06d
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
KEY PLAN PART A
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 5:02:38 PM
I-300BA
LEE
B A
S E
M E
N T
S
IG
N A
G E
P L A
N
P A
R T
A
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/4" = 1'-0"1A
BASEMENT - SIGNAGE PLAN - PART A
F E
C
N
N
STAIR 1
LS-B-1
ELECTRICAL
LC004
TEAM ROOM 1 -
WKTM1
LC040
STAFF TOILET -
TLTU1
LC002
SCREENING /
TRIAGE ROOM
EXRG4
LC030
PATIENT TOILET -
TLTU1
LC007
CLEAN - UCCL1
LC006
SCREENING /
TRIAGE ROOM
EXRG4
LC032
SPECIALTY ROOM
EXRG1
LC034
EXAM ROOM
EXRG1
LC036
EXAM ROOM
EXRG1
LC038
EQUIPMENT
STORAGE - SRE01
LC003
EXAM ROOM
EXRG1
LC039
EXAM ROOM
EXRG1
LC037
EXAM ROOM
EXRG1
LC035
EXAM ROOM
EXRG1
LC033
EXAM ROOM
EXRG1
LC031
CIRCULATION
LC02
ISOLATION
EXRG6
LC011a
TEAM ROOM 2 -
WKTM1
LC005
TOILET
TLTU1
LC011b
HEIGHT /
WEIGHT
LC010
CONSULT
(BH/NUTRITION)
OFDC2
LC008
SOILED LINEN -
USCL1
LC009
MECHANICAL
L001a
COPY SUPPLY
RPR01
LC12c
TEAM ROOM 3-4 -
WKTM1
LC001
/A1 I-200BA /A1 I-200BB
CIRCULATION
LC02
S-B-12
S-B-37
S-B-16b S-B-17b
S-B-36 S-B-34
S-B-35 S-B-33
S-B-32
S-B-30
S-B-31 S-B-29
S-B-27
S-B-25
S-B-24
S-B-22
S-B-21S-B-19S-B-18
S-B-15
S-B-16a S-B-17a
S-B-14
S-B-28
S-B-20a
S-B-23
S-B-13a
S-B-20b
S-B-20c
S-B-20d
S-B-09
S-B-50
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
PART BKEY PLAN
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 5:02:39 PM
I-300BB
LEE
B A
S E
M E
N T
S
IG
N A
G E
P L A
N
P A
R T
B
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
BASEMENT - SIGNAGE PLAN - PART B
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:41:47 PM
I-301
LEE
F
IR
S T
F L O
O R
S
IG
N A
G E
S C
H E
D U
L E
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
SIGNAGE SCHEDULE - FIRST FLOOR
Sign Code Sign Type Room Number Room Name Message Count Comments
S-1-01 B L109 EQUIPMENT CLEANING AREA L109 / EQUIPMENT CLEANING AREA 1
S-1-02a S-1 LE-1-1 ELEVATOR - 1
S-1-02b N LE-1-1 ELEVATOR - 1 COORDINATE MAP IMAGE WITH LEVEL
S-1-02c L LE-1-1 ELEVATOR - 1
S-1-03a J LS-1-2 STAIR 02 - 1
S-1-03b J LS-1-2 STAIR 02 - 1
S-1-03c M LS-1-2 STAIR 02 - 1
S-1-03d K LS-1-2 STAIR 02 - 1
S-1-03e P1 LS-1-2 STAIR 02 - 1
S-1-03f J LS-1-2 STAIR 02 - 1
S-1-04 B L110A MAIN TELECOM - CHC L110A / MAIN TELECOM 1
S-1-05 B L110B MAIN TELECOM - CADET L110B / MAIN TELECOM 1
S-1-06 B L111 TRUNK ROOM L111 / TRUNK ROOM 1
S-1-07 B L107 STORAGE L107 / STORAGE 1
S-1-08 B L112 ELEVATOR MACHINE ROOM L112 / ELEVATOR MACHINE ROOM 1
S-1-09 D L106 WOMENS ROOM L106 / WOMENS ROOM 1
S-1-10 B L113 TAC SUPPORT L113 / TAC SUPPORT 1
S-1-11a B L114 TRUNK ROOM L114 / TRUNK ROOM 1
S-1-11b B L114 TRUNK ROOM L114 / TRUNK ROOM 1
S-1-12 B L102 ELECTRICAL L102 / ELECTRICAL ROOM 1
S-1-13 B L101b JANITOR OFFICE L101b / JANITOR OFFICE 1
S-1-14 B L101a JANITOR BREAK ROOM L101A / JANITOR BREAK ROOM 1
S-1-15 B L104 STORAGE L104 / STORAGE ROOM 1
S-1-16 C L105 MENS ROOM L105 / MENS ROOM 1
S-1-17a J LS-1-1 STAIR 01 - 1
S-1-17b J LS-1-1 STAIR 01 - 1
S-1-17c M LS-1-1 STAIR 01 - 1
S-1-17d O1 LS-1-1 STAIR 01 - 1
S-1-17e K LS-1-1 STAIR 01 - 1
Grand total 29
STAIR 2
LS-1-2
ELEV.
LE-1-1
VESTIBULE
L108
STORAGE
L107
MAIN TELECOM -
CHC
L110A
MAIN TELECOM -
CADET
L110B
EQUIPMENT
CLEANING AREA
L109
TRUNK ROOM
L111
WOMEN'S ROOM
L106
TAC SUPPORT
L113
CORRIDOR
L100
/A1 I-201A /A1 I-201B
ELEVATOR
MACHINE ROOM
L112
S-1-02a S-1-02b S-1-02c
S-1-01
S-1-04
S-1-05
S-1-06
S-1-03f
S-1-03e
S-1-03c
S-1-03d
S-1-07
S-1-08
S-1-09
S-1-03b
S-1-03a
EXIT
THIS LEVEL
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
KEY PLAN PART A
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:41:50 PM
I-301A
LEE
F
IR
S T
F L O
O R
S
IG
N A
G E
P L A
N
P A
R T
A
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
FIRST FLOOR - SIGNAGE PLAN - PART A
CORRIDOR
L100
MEN'S ROOM
L105
TAC SUPPORT
L113
TRUNK ROOM
L114
JANITORS BREAK
ROOM
L101a
ELEC.
L102
JANITOR'S
OFFICE
L101b
STAIR 1
LS-1-1
VESTIBULE
L103STORAGE
L104
/A1 I-201A /A1 I-201B
S-1-09
S-1-10 S-1-11a
S-1-16 S-1-15 S-1-17a
S-1-11b
S-1-12
S-1-14
S-1-13
S-1-17c
S-1-17d
S-1-17e
S-1-17b EXIT THIS
LEVEL
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
PART BKEY PLAN
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:41:53 PM
I-301B
LEE
F
IR
S T
F L O
O R
S
IG
N A
G E
P L A
N
P A
R T
B
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
FIRST FLOOR - SIGNAGE PLAN - PART B
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:41:56 PM
I-302
LEE
S E
C O
N D
F L O
O R
S
IG
N A
G E
S C
H E
D U
L E
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
SIGNAGE SCHEDULE - SECOND FLOOR
Sign Code Sign Type Room Number Room Name Message Count Comments
S-2-01 A L2015 CADET ROOM L2015 1
S-2-02 A L2014 CADET ROOM L2014 1
S-2-03a N LE-2-1 ELEVATOR - 1 COORDINATE MAP IMAGE WITH LEVEL
S-2-03b S-2 LE-2-1 ELEVATOR - 1
S-2-03c L LE-2-1 ELEVATOR - 1
S-2-04 A L2013 CADET ROOM L2013 1
S-2-05 A L2012 CADET ROOM L2012 1
S-2-06a H LS-2-2 STAIR 2 - 1
S-2-06b K LS-2-2 STAIR 2 - 1
S-2-06c P2 LS-2-2 STAIR 2 - 1
S-2-06d M LS-2-2 STAIR 2 - 1
S-2-07 A L2011 CADET ROOM L2011 1
S-2-08 C L208 MENS ROOM L208 / MENS ROOM 1
S-2-09 E LS207 UNISEX TLT LS207 / UNISEX TOILET 1
S-2-10 B L206 TELECOM L206 / TELECOM 1
S-2-11 A L2010 CADET ROOM L2010 1
S-2-12a B L205 COLLABORATION ROOM L205 / COLLABORATION 1
S-2-12b B L205 COLLABORATION ROOM L205 / COLLABORATION 1
S-2-12c F L205 COLLABORATION ROOM 45 1
S-2-13 A L2009 TAC ROOM L2009 1
S-2-14 A L2008 TAC ROOM L2008 1
S-2-15 A L2007 TAC ROOM L2007 1
S-2-16 B L204 JANITOR L204 / JANITOR CLOSET 1
S-2-17 A L2006 CADET ROOM L2006 1
S-2-18 B L203 LAUNDRY L203 / LAUNDRY 1
S-2-19 A L2005 CADET ROOM L2005 1
S-2-20 D L202 WOMENS ROOM L202 / WOMENS ROOM 1
S-2-21 A L2004 CADET ROOM L2004 1
S-2-22a H LS-2-1 STAIR 1 - 1
S-2-22b K LS-2-1 STAIR 1 - 1
S-2-22c O2 LS-2-1 STAIR 1 - 1
S-2-22d M LS-2-1 STAIR 1 - 1
S-2-23 A L2003 CADET ROOM L2003 1
S-2-24 B L201 ELECTRICAL ROOM L201 / ELECTRICAL ROOM 1
S-2-25 A L2002 CADET ROOM L2002 1
S-2-26 A L2001 CADET ROOM L2001 1
Grand total 36
ELEV.
LE-2-1
STAIR 2
LS-2-2
CADET ROOM
L2015
CORRIDOR
L200
TAC
L2008
TAC
L2009
CADET ROOM
L2010
CADET ROOM
(ABA)
L2011
CADET ROOM
L2012
CADET ROOM
L2013
CADET ROOM
L2014
MEN'S ROOM
L208
TELECOM
L206
/A1 I-202A /A1 I-202B
ABA TOILET
ROOM
LS207
S-2-01
S-2-02
S-2-03a S-2-03b S-2-03c
S-2-04 S-2-05
S-2-06b
S-2-06c
S-2-06d
S-2-06a S-2-08 S-2-09
S-2-07
S-2-10
S-2-11 S-2-13
S-2-12a
S-2-14
S-2-12c
COLLABORATION
ROOM
L205
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
KEY PLAN PART A
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:41:59 PM
I-302A
LEE
S E
C O
N D
F L O
O R
S
IG
N A
G E
P L A
N
P A
R T
A
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
SECOND FLOOR - SIGNAGE PLAN - PART A
S3
STAIR 1
LS-2-1
LAUNDRY
L203
COLLABORATION
ROOM
L205
CADET ROOM
L2001
CADET ROOM
L2002
CADET ROOM
L2003
CADET ROOM
L2004
CADET ROOM
L2005
CADET ROOM
L2006
TAC
L2007
TAC
L2008
ELEC.
L201
WOMEN'S ROOM
L202
JANITOR
L204
CORRIDOR
L200
/A1 I-202A /A1 I-202B
(4)
S-2-14
S-2-12b
S-2-15
S-2-16
S-2-17 S-2-19
S-2-18
S-2-21
S-2-22a
S-2-22b
S-2-22c
S-2-22d
S-2-20
S-2-26S-2-24
S-2-25S-2-23
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
PART BKEY PLAN
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:03 PM
I-302B
LEE
S E
C O
N D
F L O
O R
S
IG
N A
G E
P L A
N
P A
R T
B
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
SECOND FLOOR - SIGNAGE PLAN - PART B
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:05 PM
I-303
LEE
T H
IR
D
F L O
O R
S
IG
N
A G
E S
C H
E D
U L E
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
SIGNAGE SCHEDULE - THIRD FLOOR
Sign Code Sign Type Room Number Room Name Message Count Comments
S-3-01 A L3015 CADET ROOM L3015 1
S-3-02 A L3016 CADET ROOM L3016 1
S-3-03a N LE-3-1 ELEVATOR - 1 COORDINATE MAP IMAGE WITH LEVEL
S-3-03b S-2 LE-3-1 ELEVATOR - 1
S-3-03c L LE-3-1 ELEVATOR - 1
S-3-04 A L3014 CADET ROOM L3014 1
S-3-05 A L3013 CADET ROOM L3013 1
S-3-06a H LS-3-2 STAIR 2 - 1
S-3-06b K LS-3-2 STAIR 2 - 1
S-3-06c P2 LS-3-2 STAIR 2 - 1
S-3-06d M LS-3-2 STAIR 2 - 1
S-3-07 C L308 MENS ROOM L308 / MENS ROOM 1
S-3-08 A L3012 CADET ROOM L3012 1
S-3-09 B L307 JANITOR L307 / JANITOR 1
S-3-10 A L3011 CADET ROOM L3011 1
S-3-11 B L306 TELECOM L306 / TELECOM 1
S-3-12 A L3010 CADET ROOM L3010 1
S-3-13 A L3009 CCQ L3009 1
S-3-14 A L3008 CADET ROOM L3008 1
S-3-15a B L305a COLLABORATION ROOM L305a / COLLABORATION ROOM 1
S-3-15b F L305a COLLABORATION ROOM L305a / COLLABORATION ROOM 1
S-3-16 B L305b COLLABORATION STORAGE ROOM L305b / COLLABORATION STORAGE ROOM 1
S-3-17 A L3007 CADET ROOM L3007 1
S-3-18 B L304 STORAGE L304 / STORAGE 1
S-3-19 A L3006 CADET ROOM L3006 1
S-3-20 B L303 LAUNDRY L303 / LAUNDRY 1
S-3-21 A L3005 CADET ROOM L3005 1
S-3-22 D L302 WOMENS ROOM L302 / WOMENS ROOM 1
S-3-23a H LS-3-1 STAIR 1 - 1
S-3-23b K LS-3-1 STAIR 1 - 1
S-3-23c O2 LS-3-1 STAIR 1 - 1
S-3-23d M LS-3-1 STAIR 1 - 1
S-3-24 A L3004 CADET ROOM L3004 1
S-3-25 A L3003 CADET ROOM L3003 1
S-3-26 B L301 ELECTRICAL L301 / ELECTRICAL 1
S-3-27 A L3002 CADET ROOM L3002 1
S-3-28 A L3001 CADET ROOM L3001 1
Grand total 37
CADET ROOM
L3015
CORRIDOR
L300
CADET ROOM
L3008
CADET ROOM
L3010
CADET ROOM
L3011
CADET ROOM
L3012
CADET ROOM
L3013
CADET ROOM
L3014
CADET ROOM
L3016
STAIR 2
LS-3-2
ELEV.
LE-3-1
MEN'S ROOM
L308
JANITOR
L307
TELECOM
L306
CCQ
L3009
/A1 I-203A /A1 I-203B
S-3-01
S-3-02 S-3-04
S-3-03a S-3-03b S-3-03c
S-3-05
S-3-06a
S-3-08
S-3-07 S-3-09
S-3-10
S-3-11
S-3-12
S-3-13 S-3-15a
S-3-14
S-3-06b
S-3-06c
S-3-06d
COLLABORATION
ROOM
L305a
S-3-15b
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
KEY PLAN PART A
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:09 PM
I-303A
LEE
T H
IR
D
F L O
O R
S
IG
N
A G
E P
L A
N
P A
R T
A
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
THIRD FLOOR - SIGNAGE PLAN - PART A
COLLABORATION
ROOM
L305a
CADET ROOM
L3001
CADET ROOM
L3002
CADET ROOM
L3003
CADET ROOM
L3004
CADET ROOM
L3005
CADET ROOM
L3006
CADET ROOM
L3007
CADET ROOM
L3008
STAIR 1
LS-3-1
WOMEN'S ROOM
L302
ELEC.
L301
STORAGE
L304
COLLABORATION
STORAGE ROOM
L305b
LAUNDRY
L303
(2)
CORRIDOR
L300
/A1 I-203A /A1 I-203B
S-3-15a
S-3-14 S-3-17 S-3-19
S-3-18 S-3-20
S-3-21
S-3-23a
S-3-24
S-3-22
S-3-25
S-3-26 S-3-28
S-3-27
S-3-23b
S-3-23c
S-3-23d
S-3-16
S-3-15b
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
PART BKEY PLAN
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:12 PM
I-303B
LEE
T H
IR
D
F L O
O R
S
IG
A
N G
E P
L A
N
P A
R T
B
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/4" = 1'-0"1B
THIRD FLOOR - SIGNAGE PLAN - PART B
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:15 PM
I-304
LEE
F O
U R
T H
F L O
O R
S
IG
N A
G E
S C
H E
D U
L E
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
SIGNAGE SCHEDULE - FOURTH FLOOR
Sign Code Sign Type Room Number Room Name Message Count Comments
S-4-01 A L4019 CADET ROOM L4019 1
S-4-02 A L4018 CADET ROOM L4018 1
S-4-03a N LE-4-1 ELEVATOR - 1 COORDINATE MAP IMAGE WITH LEVEL
S-4-03b S-2 LE-4-1 ELEVATOR - 1
S-4-03c L LE-4-1 ELEVATOR - 1
S-4-04 A L4017 CADET ROOM L4017 1
S-4-05 A L4016 CADET ROOM L4016 1
S-4-06a H LS-4-2 STAIR 2 - 1
S-4-06b K LS-4-2 STAIR 2 - 1
S-4-06c P2 LS-4-2 STAIR 2 - 1
S-4-06d M LS-4-2 STAIR 2 - 1
S-4-07 C L408 MENS ROOM L408 / MENS ROOM 1
S-4-08 A L4015 CADET ROOM L4015 1
S-4-09 B L407 JANITOR L407 / JANITOR 1
S-4-10 B L406 TELECOM L406 / TELECOM 1
S-4-11 A L4014 CADET ROOM L4014 1
S-4-12 A L4012 CADET ROOM L4012 1
S-4-13 A L4013 CADET ROOM L4013 1
S-4-14 A L4010 CADET ROOM L4010 1
S-4-15 A L4011 CADET ROOM L4011 1
S-4-16 A L4009 CADET ROOM L4009 1
S-4-17 A L4008 CADET ROOM L4008 1
S-4-18 B L404 STORAGE L404 /STORAGE 1
S-4-19 A L4006 CADET ROOM L4006 1
S-4-20 B L403 LAUNDRY L403 / LAUNDRY 1
S-4-21 A L4005 CADET ROOM L4005 1
S-4-22 A L4007 CADET ROOM L4007 1
S-4-23 D L402 WOMENS ROOM L402 / WOMENS ROOM 1
S-4-24a H LS-4-1 STAIR 1 - 1
S-4-24b K LS-4-1 STAIR 1 - 1
S-4-24c O2 LS-4-1 STAIR 1 - 1
S-4-24d M LS-4-1 STAIR 1 - 1
S-4-25 A L4004 CADET ROOM L4004 1
S-4-26 A L4003 CADET ROOM L4003 1
S-4-27 B L401 ELECTRICAL L401 / ELECTRICAL 1
S-4-28 A L4002 CADET ROOM L4002 1
S-4-29 A L4001 CADET ROOM L4001 1
Grand total 37
L4019
CADET ROOM
L4013
CORRIDOR
L400
CADET ROOM
L4010
CADET ROOM
L4012
CADET ROOM
L4014
CADET ROOM
L4015
CADET ROOM
L4016
CADET ROOM
L4017
CADET ROOM
L4018
TELECOM
L406
MEN'S ROOM
L408
STAIR 2
LS-4-2
JANITOR
L407
ELEV.
LE-4-1
/A1 I-204A /A1 I-204B
S-4-01
S-4-02
S-4-03a S-4-03b S-4-03c
S-4-04 S-4-05
S-4-06a
S-4-06b
S-4-06c
S-4-06d
S-4-07 S-4-09
S-4-08
S-4-10
S-4-11 S-4-12
S-4-13
S-4-14
S-4-15
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
KEY PLAN PART A
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:18 PM
I-304A
LEE
F O
U R
T H
F L O
O R
S
IG
N A
G E
P L A
N
P A
R T
A
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
FOURTH FLOOR - SIGNAGE PLAN - PART A
L4007
CADET ROOM
L4011
CADET ROOM
L4009
CADET ROOM
L4001
CADET ROOM
L4002
CADET ROOM
L4003
CADET ROOM
L4004
CADET ROOM
L4005
CADET ROOM
L4006
CADET ROOM
L4008
CADET ROOM
L4010
WOMEN'S ROOM
L402
LAUNDRY
L403
STAIR 1
LS-4-1
STORAGE
L404
CORRIDOR
CORRIDOR
L400
/A1 I-204A /A1 I-204B
ELECTRICAL
L401
S-4-15
S-4-14
S-4-16
S-4-17
S-4-18
S-4-19
S-4-20
S-4-21
S-4-24a
S-4-25 S-4-26 S-4-28
S-4-29S-4-27
S-4-22
S-4-23
S-4-24b
S-4-24c
S-4-24d
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
PART BKEY PLAN
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:22 PM
I-304B
LEE
F O
U R
T H
F L O
O R
S
IG
N A
G E
P L A
N
P A
R T
B
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
FOURTH FLOOR - SIGANGE PLAN - PART B
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:24 PM
I-305
LEE
F
IF
T H
F L O
O R
S
IG
N A
G E
S C
H E
D U
L E
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
SIGNAGE SCHEDULE - FIFTH FLOOR
Sign Code Sign Type Room Number Room Name Message Count Comments
S-5-01 A L5019 CADET ROOM L5019 1
S-5-02 A L5018 CADET ROOM L5018 1
S-5-03a N LE-5-1 ELEVATOR - 1 COORDINATE MAP IMAGE WITH LEVEL
S-5-03b S-2 LE-5-1 ELEVATOR - 1
S-5-03c L LE-5-1 ELEVATOR - 1
S-5-04 A L5017 CADET ROOM L5017 1
S-5-05 A L5016 CADET ROOM L5016 1
S-5-06a H LS-5-2 STAIR 2 - 1
S-5-06b K LS-5-2 STAIR 2 - 1
S-5-06c P2 LS-5-2 STAIR 2 - 1
S-5-06d M LS-5-2 STAIR 2 - 1
S-5-07 C L508 MENS ROOM L508 / MENS ROOM 1
S-5-08 B L507 JANITOR L507 / JANITOR 1
S-5-09 A L5015 CADET ROOM L5015 1
S-5-10 B L506 TELECOM L506 / TELECOM 1
S-5-11 A L5014 CADET ROOM L5014 1
S-5-12 A L5013 CADET ROOM L5013 1
S-5-13 A L5012 CADET ROOM L5012 1
S-5-14 A L5011 CADET ROOM L5011 1
S-5-15 A L5010 CADET ROOM L5010 1
S-5-16 A L5009 CADET ROOM L5009 1
S-5-17 A L5006 CADET ROOM L5006 1
S-5-18 B L504 STORAGE L504 / STORAGE 1
S-5-19 A L5006 CADET ROOM L5006 1
S-5-20 B L503 LAUNDRY L503 / LAUNDRY 1
S-5-21 A L5005 CADET ROOM L5005 1
S-5-22 D L502 WOMENS ROOM L502 / WOMENS ROOM 1
S-5-23a H LS-5-1 STAIR 1 - 1
S-5-23b K LS-5-1 STAIR 1 - 1
S-5-23c O2 LS-5-1 STAIR 1 - 1
S-5-23d M LS-5-1 STAIR 1 - 1
S-5-24 A L5004 CADET ROOM L5004 1
S-5-25 A L5003 CADET ROOM L5003 1
S-5-26 B L501 ELECTRICAL L501 / ELECTRICAL 1
S-5-27 A L5002 CADET ROOM L5002 1
S-5-28 A L5001 CADET ROOM L5001 1
S-5-29 A L5007 CADET ROOM L5007 1
Grand total
L5019
CADET ROOM
L5013
CADET ROOM
L5011
CADET ROOM
L5018
MEN'S ROOM
L508
TELECOM
L506
CADET ROOM
L5017
CADET ROOM
L5016
CADET ROOM
L5015
CADET ROOM
L5014
CADET ROOM
L5012
CADET ROOM
L5010
JANITOR
L507
ELEV.
LE-5-1
/A1 I-205A /A1 I-205B
CORRIDOR
L500
STAIR 2
LS-5-2
S-5-01
S-5-02
S-5-03a
S-5-04
S-5-03b S-5-03c
S-5-05
S-5-06a
S-5-06b
S-5-06c
S-5-06d
S-5-07
S-5-09
S-5-08
S-5-11
S-5-10 S-5-12
S-5-13
S-5-14
S-5-15
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
KEY PLAN PART A
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:28 PM
I-305A
LEE
F
IF
T H
F L O
O R
S
IG
N A
G E
P L A
N
P A
R T
A
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
FIFTH FLOOR - SIGNAGE PLAN - PART A
L5007
CADET ROOM
L5011
CADET ROOM
L5009
CADET ROOM
L5001
CORRIDOR
L500
ELEC.
L501
WOMEN'S ROOM
L502
LAUNDRY
L503
CADET ROOM
L5010
CADET ROOM
L5008
CADET ROOM
L5006
CADET ROOM
L5005
CADET ROOM
L5004
CADET ROOM
L5003
CADET ROOM
L5002
STORAGE
L504
CORRIDOR
L500b
STAIR 1
LS-5-1
/A1 I-205A /A1 I-205B
S-5-14
S-5-15 S-5-17
S-5-16 S-5-18
S-5-19
S-5-20
S-5-21 S-5-24
S-5-23a
S-5-23b
S-5-23c
S-5-23d
S-5-26
S-5-25 S-5-27
S-5-28
S-5-22
S-5-29
1. REFER TO SHEET I-300.1 - I-300.5 FOR SIGNAGE TYPES AND
DETAILS.
2. REFERT TO SHEETS I-3X0 FOR SIGNAGE SCHEDULE PER FLOOR.
3. ROOM NUMBERS AND TEXT OF ALL SIGNS MUST BE VERIFIED AND
COORDINATED WITH CONTRACTING OFFICER REPRESENTATIVE.
4. VERIFY LOCATIONS AND GRAPHICS ASSOCIATED WITH
EGRESS/FIRE SAFETY WITH FIRE MARSHAL.
SIGNAGE NOTES
SIGNAGE LEGEND
S-X-XXa
SIGNAGE
FLOOR NUMBER
SIGNAGE CODE # PER SPACE
LETTER SUFFIX FOR
MULTIPLES IN A SPACE
S - WALL MOUNTED SIGANGE (CFCI)
C - CEILING MOUNTED SIGNAGE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
PART BKEY PLAN
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:31 PM
I-305B
LEE
F
IF
T H
F L O
O R
S
IG
N A
G E
P L A
N
P A
R T
B
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
FIFTH FLOOR - SIGNAGE PLAN - PART B
UP FEC
SS
S
FEC
SSSSSS
S
GENERAL FLOOR PATTERN NOTES
1. REFER TO SHEET I-001 FOR FINISH SCHEDULE, GENERAL NOTES, AND MATERIAL
CODES.
2. REFER TO FINISH SCHEDULE ON I-001 FOR ADDITIONAL INFORMATION
REGARDING TERRAZZO ACCENT COLORS USED ON EACH FLOOR.
3. FIELD VERIFY DIMENSIONS PRIOR TO INSTALLATION OF FLOOR TILE.
4. ALL TRANSITIONS OF FLOOR MATERIALS SHALL TRANSITION AT THRESHOLD.
CENTERED BENEATH DOOR WHEN CLOSED. UNO
5. REFER TO I-500 SHEETS FOR TYP. FINISH DETAILS/TRANSITIONS
FLOOR PATTERN LEGEND
TZ1 - POURED TERRAZZO FIELD
TZ# - POURED TERRAZZO
ACCENT (SEE FINISH PLANS FOR
DEFINITION)
TZ5 / TZ12 - POURED TERRAZZO
TZ6 - POURED TERRAZZO
TZ7 - POURED TERRAZZO
TZ10 - POURED TERRAZZO
TZ13 - POURED TERRAZZO
TZ11 - POURED TERRAZZO
TOILET
LCS11
TOILET
LCS10
EYE LANE - EYEL1
LCS08
HEARING BOOTH -
PEHS2
LCS05
WAITING ROOM -
WRC01
LCS04
PLUMBING
LS01b
TELECOM
LS05
PLUMBING CLEAN
OUT ROOM
LB001c
STORAGE
LS07
VESTIBULE -
LOB02
LS09
CIRCULATION
LCS001
STAIR 2
LS-S-2
ELEVATOR 1
LE-S-1 STAIR 1
LS-S-1
BEAUTY
STORAGE
LB010
BEAUTY SHOP
LB003
LAUNDRY
LB009
AIR/VAC
LB001d
JANITOR CLOSET
LS06
BARBER SHOP
LB001a
CHC STAIR 4
LS-S-4
ELEVATOR 2
LE-S-2
OFFICE
LB004
CLINIC
PHARMACY -
PHOD1
LCS01
EXIT PASSAGE
LCS002
CIRCULATION
LCS003
MECHANICAL
LS03
BARBER
STORAGE
LB001e
ELECTRICAL
LS02
EYE VISION
SCREENING
DISPENSING -
EYVS1
LCS07
STORAGE
LCS09
RECEPTION
LCS02
WHEELCHAIR
ALCOVE
LCS06
KIOSK -
CLSC1
LCS04b
AED -
RCA01
LCS03
MEN'S ROOM
LB007
WOMEN'S ROOM
LB006
STAFF LOUNGE
LB005
CHECK-IN KIOSKS
LB002
STAFF SUPPORT
LB01
MIXING
LB008
VENDING AREA
LS04
VESTIBULE
LS10
STORAGE
LB001b
APRON & COAT
HOOKS
LB001f
ROOF ACCESS
STAIR 3
LS-S-3
I-405
A7
I-405
A1 I-405
E1
I-406
A1
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:35 PM
I-400
LEE
T Y
P
IC
A L F
L O
O R
P A
T T
E R
N P
L A
N
S U
B -B
A S
E M
E N
T
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"A1
OVERALL FLOOR PATTER PLAN -
SUB-BASEMENT
F E
C
N
S
N
SS
S
S
SD
S
N
FIRE PUMP ROOM
LB001
STAIR 2
LS-B-2
ELEV. 1
LE-B-1
STAIR 1
LS-B-1
ELECTRICAL
LC004
TEAM ROOM 1 -
WKTM1
LC040
STAFF TOILET -
TLTU1
LC002
SCREENING /
TRIAGE ROOM
EXRG4
LC030
LABORATORY -
LBPC1
LC015b
BLOOD DRAW -
LBVP1
LC015a
PATIENT TOILET -
TLTU1
LC007
CLEAN - UCCL1
LC006SCREENING /
TRIAGE ROOM
EXRG4
LC032
SPECIALTY ROOM
EXRG1
LC034
EXAM ROOM
EXRG1
LC036
EXAM ROOM
EXRG1
LC038
STAFF LOUNGE -
SL001
LC018
STAFF TOILET -
TLTU1
LC020
OFFICE TBI
RESEARCH
ANALYST - OFA05
LC019
OFFICE CARE
COORDINATOR-
OFA04
LC025
OFFICE NCOIC /
CNOC - OFA05
LC023
OBSERVATION /
HYDRATION -
OOHR1
LC028b
ELEVATOR 2
LE-B-2
WAITING
ANCILLARY
SERVICES
LC01c
MECHANICAL
L001a EQUIPMENT
STORAGE - SRE01
LC003
EXAM ROOM
EXRG1
LC039
EXAM ROOM
EXRG1
LC037
EXAM ROOM
EXRG1
LC035
EXAM ROOM
EXRG1
LC033
EXAM ROOM
EXRG1
LC031
COPY SUPPLY
RPR01
LC12c
WAITING ROOM
LC01d
EVS
JANC1
LC027
CIRCULATION
LC03
CIRCULATION
LC02
ISOLATION
EXRG6
LC011a
CHC STAIR 4
LS-B-4
TEAM ROOM 2 -
WKTM1
LC005
TOILET
TLTU1
LC011b
HEIGHT /
WEIGHT
LC010
CONSULT
(BH/NUTRITION)
OFDC2
LC008
SOILED LINEN -
USCL1
LC009
OFFICE OIC/CHIEF
- OFA04
LC024
CONFERENCE
ROOM - CRA01
LC026
OFFICE CARE
COORDINATOR -
OFA04
LC021
AED -
RCA01
LC016
SPECIMEN TOILET
- TLTU1
LC017
RECEPTION
LC012a
APPOINTMENT
CLERK
LC012b
WHEELCHAIR
ALCOVE - SRLW1
LC013
TREATMENT/IMMUNIZATION
- TRGM1/OPIR1
LC029
NURSE STATION -
NSTA1
LC028a
TEAM ROOM 3-4 -
WKTM1
LC001
CADET SURGEON
- OFA04
LC022
TOILET
TLTU1
LC014
CIRCULATION
L101g
CIRCULATION
LC02
FLOOR PATTERN LEGEND
TZ1 - POURED TERRAZZO FIELD
TZ# - POURED TERRAZZO
ACCENT (SEE FINISH PLANS FOR
DEFINITION)
TZ5 / TZ12 - POURED TERRAZZO
TZ6 - POURED TERRAZZO
TZ7 - POURED TERRAZZO
TZ10 - POURED TERRAZZO
TZ13 - POURED TERRAZZO
TZ11 - POURED TERRAZZO
GENERAL FLOOR PATTERN NOTES
1. REFER TO SHEET I-001 FOR FINISH SCHEDULE, GENERAL NOTES, AND MATERIAL
CODES.
2. REFER TO FINISH SCHEDULE ON I-001 FOR ADDITIONAL INFORMATION
REGARDING TERRAZZO ACCENT COLORS USED ON EACH FLOOR.
3. FIELD VERIFY DIMENSIONS PRIOR TO INSTALLATION OF FLOOR TILE.
4. ALL TRANSITIONS OF FLOOR MATERIALS SHALL TRANSITION AT THRESHOLD.
CENTERED BENEATH DOOR WHEN CLOSED. UNO
5. REFER TO I-500 SHEETS FOR TYP. FINISH DETAILS/TRANSITIONS
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:40 PM
I-401
LEE
T Y
P
IC
A L F
L O
O R
P A
T T
E R
N P
L A
N
B A
S E
M E
N T
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"A1
OVERALL FLOOR PATTERN PLAN - BASEMENT
FECFEC
S3
FECFEC
I-403
A5
I-403
E6
I-404
A4
I-404
A1
I-403
E6
169' - 2 1/2"
GENERAL FLOOR PATTERN NOTES
1. REFER TO SHEET I-001 FOR FINISH SCHEDULE, GENERAL NOTES, AND MATERIAL
CODES.
2. REFER TO FINISH SCHEDULE ON I-001 FOR ADDITIONAL INFORMATION
REGARDING TERRAZZO ACCENT COLORS USED ON EACH FLOOR.
3. FIELD VERIFY DIMENSIONS PRIOR TO INSTALLATION OF FLOOR TILE.
4. ALL TRANSITIONS OF FLOOR MATERIALS SHALL TRANSITION AT THRESHOLD.
CENTERED BENEATH DOOR WHEN CLOSED. UNO
5. REFER TO I-500 SHEETS FOR TYP. FINISH DETAILS/TRANSITIONS
FLOOR PATTERN LEGEND
TZ1 - POURED TERRAZZO FIELD
TZ# - POURED TERRAZZO
ACCENT (SEE FINISH PLANS FOR
DEFINITION)
TZ5 / TZ12 - POURED TERRAZZO
TZ6 - POURED TERRAZZO
TZ7 - POURED TERRAZZO
TZ10 - POURED TERRAZZO
TZ13 - POURED TERRAZZO
TZ11 - POURED TERRAZZO
04 8 16268
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:45 PM
I-402
LEE
T Y
P
IC
A L F
L O
O R
P A
T T
E R
N P
L A
N
T Y
P
C O
R R
ID
O
R S
S
T A
IR
S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/8" = 1'-0"D1
TYPICAL FLOOR PATTERN PLAN - CORRIDOR & STAIR
1/8" = 1'-0"A1
TYPICAL FLOOR PATTERN PLAN - CORRIDOR & STAIR - FIRST FLOOR
GENERAL FLOOR PATTERN NOTES
1. REFER TO SHEET I-001 FOR FINISH SCHEDULE, GENERAL NOTES, AND MATERIAL
CODES.
2. REFER TO FINISH SCHEDULE ON I-001 FOR ADDITIONAL INFORMATION
REGARDING TERRAZZO ACCENT COLORS USED ON EACH FLOOR.
3. FIELD VERIFY DIMENSIONS PRIOR TO INSTALLATION OF FLOOR TILE.
4. ALL TRANSITIONS OF FLOOR MATERIALS SHALL TRANSITION AT THRESHOLD.
CENTERED BENEATH DOOR WHEN CLOSED. UNO
5. REFER TO I-500 SHEETS FOR TYP. FINISH DETAILS/TRANSITIONS
FLOOR PATTERN LEGEND
TZ1 - POURED TERRAZZO FIELD
TZ# - POURED TERRAZZO
ACCENT (SEE FINISH PLANS FOR
DEFINITION)
TZ5 / TZ12 - POURED TERRAZZO
TZ6 - POURED TERRAZZO
TZ7 - POURED TERRAZZO
TZ10 - POURED TERRAZZO
TZ13 - POURED TERRAZZO
TZ11 - POURED TERRAZZO
ALIGNALIGN
1' - 0"2' - 0" 1' - 0" EQ 1' - 0" 2' - 0" 1' - 0" EQ 1' - 0" 2' - 0" 1' - 0"
CL
EQ
OF WINDOW
EQ
ALIGN
TYP. CORRIDOR
1' - 0" A
L
IG
N
TYP.
CORRIDOR
1' - 0" 2' - 0" 1' - 0"
VIF
13' - 2" 1' - 0" 2' - 0" 1' - 0"
VIF
11' - 11" 1' - 0" 2' - 0" 1' - 0"
ALIGN
CL
EQ
OF WINDOW
EQ
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:50 PM
I-403
LEE
E N
L A
R G
D
L O
O R
P A
T T
E R
N P
L A
N
C A
D E
T R
O O
M
C O
L L A
B O
R A
T
IO
N R
O O
M
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/4" = 1'-0"A5
FLOOR PATTERN PLAN - COLLABORATION ROOM (L205) - SECOND
FLOOR
1/4" = 1'-0"E6
FLOOR PATTERN PLAN - TYPICAL CADET,
TAC, CCQ & BATTALION RMS
1/4" = 1'-0"D1
FLOOR PATTERN PLAN - A-TYPICAL CADET ROOM
1/4" = 1'-0"A1
FLOOR PATTERN PLAN - COLLABORATION ROOM (L305) - THIRD
FLOOR
TILE PATTERN START POINT
I-404
F1
EQ EQ
CL
OF DOOR OPENING
TILE PATTERN START POINT
EQ EQ
CL
OF DOOR OPENING
I-404
F1
TILE PATTERN
START POINT
EQ EQ
CL
OF DOOR OPENING
FLOOR PATTERN LEGEND
TZ1 - POURED TERRAZZO FIELD
TZ# - POURED TERRAZZO
ACCENT (SEE FINISH PLANS FOR
DEFINITION)
TZ5 / TZ12 - POURED TERRAZZO
TZ6 - POURED TERRAZZO
TZ7 - POURED TERRAZZO
TZ10 - POURED TERRAZZO
TZ13 - POURED TERRAZZO
TZ11 - POURED TERRAZZO
GENERAL FLOOR PATTERN NOTES
1. REFER TO SHEET I-001 FOR FINISH SCHEDULE, GENERAL NOTES, AND MATERIAL
CODES.
2. REFER TO FINISH SCHEDULE ON I-001 FOR ADDITIONAL INFORMATION
REGARDING TERRAZZO ACCENT COLORS USED ON EACH FLOOR.
3. FIELD VERIFY DIMENSIONS PRIOR TO INSTALLATION OF FLOOR TILE.
4. ALL TRANSITIONS OF FLOOR MATERIALS SHALL TRANSITION AT THRESHOLD.
CENTERED BENEATH DOOR WHEN CLOSED. UNO
5. REFER TO I-500 SHEETS FOR TYP. FINISH DETAILS/TRANSITIONS
TILE WALL, TW1
ACCENT TILE WALL, TW2
(TO ALIGN GROUT JOINTS WITH TILE WALL)
TILE BASE, TB1
TILE WALL, TW1
/4
/4
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:54 PM
I-404
LEE
E N
L A
R G
D
L O
O R
P A
T T
E R
N P
L A
N
T O
IL
E
T R
O O
M S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/4" = 1'-0"D1
TYPICAL FLOOR PATTERN PLAN - WOMEN'S ROOM B
1/4" = 1'-0"A4
TYPICAL FLOOR PATTERN PLAN - MEN'S ROOM
1/4" = 1'-0"A1
TYPICAL FLOOR PATTERN PLAN - WOMEN'S ROOM A
1/2" = 1'-0"F1
TYPICAL TOILET ROOM ELEVATION - WALL TILE PATTERN
SSSSSS
S
E Q
E Q
V
IF
ALIGN
ALIGN
ALIGN
A L
IG
N
A L
IG
N
1/4" TRANSITION STRIPS
1/4" TRANSITION STRIPS
V
IF
/2
E Q
E Q
ALIGN
ALIGN
ALIGN
A L
IG
N
A L
IG
N
A L
IG
N
1/4" TRANSITION STRIP
I-405
C7
START TILE HERE
EQ EQ EQ EQ
GENERAL FLOOR PATTERN NOTES
1. REFER TO SHEET I-001 FOR FINISH SCHEDULE, GENERAL NOTES, AND MATERIAL
CODES.
2. REFER TO FINISH SCHEDULE ON I-001 FOR ADDITIONAL INFORMATION
REGARDING TERRAZZO ACCENT COLORS USED ON EACH FLOOR.
3. FIELD VERIFY DIMENSIONS PRIOR TO INSTALLATION OF FLOOR TILE.
4. ALL TRANSITIONS OF FLOOR MATERIALS SHALL TRANSITION AT THRESHOLD.
CENTERED BENEATH DOOR WHEN CLOSED. UNO
5. REFER TO I-500 SHEETS FOR TYP. FINISH DETAILS/TRANSITIONS
GENERAL WALL PATTERN NOTES
1. REFER TO SHEETS I-001 FOR FINISH SCHEDULE, GENERAL NOTES, AND MATERIAL
CODES.
2. FIELD VERIFY DIMENSIONS PRIOR TO INSTALLATION OF WALL TILE.
3. INSTALL PER MANUFACTURER'S INSTRUCTIONS.
4. OUTSIDE VERTICAL EDGE SHALL BE TERMINATED OR TURNED USING SCHLUTER
OR SIMILAR TRANSITION STRIPS IN BRUSHED STAINLESS STEEL FINISH.
FLOOR PATTERN LEGEND
TZ1 - POURED TERRAZZO FIELD
TZ# - POURED TERRAZZO
ACCENT (SEE FINISH PLANS FOR
DEFINITION)
TZ5 / TZ12 - POURED TERRAZZO
TZ6 - POURED TERRAZZO
TZ7 - POURED TERRAZZO
TZ10 - POURED TERRAZZO
TZ13 - POURED TERRAZZO
TZ11 - POURED TERRAZZO
TILE WALL,
TW5
TILE WALL,
TW5
TILE WALL ACCENT,
TW61
TILE BASE,
TB3
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:42:59 PM
I-405
LEE
E N
L A
R G
E D
F L O
O R
P A
T T
E R
N P
L A
N
B A
R B
E R
B
E A
U T
Y S
H O
P
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/4" = 1'-0"A1
B0_SUB-BASEMENT - BARBER SHOP
1/4" = 1'-0"E1
B0_SUB-BASEMENT - BEAUTY SHOP
1/4" = 1'-0"A7
ENLARGED FLOOR PATTERN PLAN -
INDIVIDUAL TOILET ROOMS
3/8" = 1'-0"C7
TYPICAL TOILET ROOM WALL PATTERN
PLAN - BARBER & BEAUTY SHOP
SS
S
ALIGN
3' - 0" 3' - 0"
V
IF
A L
IG
N I-300.5 A3
I-300.5
C5
I-300.5A1
FLOOR PATTERN LEGEND
TZ1 - POURED TERRAZZO FIELD
TZ# - POURED TERRAZZO
ACCENT (SEE FINISH PLANS FOR
DEFINITION)
TZ5 / TZ12 - POURED TERRAZZO
TZ6 - POURED TERRAZZO
TZ7 - POURED TERRAZZO
TZ10 - POURED TERRAZZO
TZ13 - POURED TERRAZZO
TZ11 - POURED TERRAZZO
GENERAL FLOOR PATTERN NOTES
1. REFER TO SHEET I-001 FOR FINISH SCHEDULE, GENERAL NOTES, AND MATERIAL
CODES.
2. REFER TO FINISH SCHEDULE ON I-001 FOR ADDITIONAL INFORMATION
REGARDING TERRAZZO ACCENT COLORS USED ON EACH FLOOR.
3. FIELD VERIFY DIMENSIONS PRIOR TO INSTALLATION OF FLOOR TILE.
4. ALL TRANSITIONS OF FLOOR MATERIALS SHALL TRANSITION AT THRESHOLD.
CENTERED BENEATH DOOR WHEN CLOSED. UNO
5. REFER TO I-500 SHEETS FOR TYP. FINISH DETAILS/TRANSITIONS
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
NORTH
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:43:03 PM
I-406
LEE
E N
L A
R G
E D
F L O
O R
P A
T T
E R
N P
L A
N
C A
D E
T H
E A
L T
H C
L
IN
IC
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
1/4" = 1'-0"A1
ENLARGED FLOOR PATTERN PLAN - SUB-BASEMENT - CADET HEALTH
CLINIC
FLOOR TILE ON THINSET
CEMENTITOUS BOND COAT
STRUCTURAL CONCRETE
FILL AT EXISTING
DEPRESSED SLAB
WATERPROOFING
MEMBRANE
EXISTING FLOOR SLAB
EPOXY GROUT
REINFORCED MESH MORTAR
BED (SLOPE TO DRAIN).
HEIGHT TO ALIGN WITH
ADJACENT STRUCTURAL
CONCRETE FILL AT EXISTING
DEPRESSED SLABS
WATERPROOFING /
CRACK MEMBRANE
EXISTING FLOOR SLAB
FLOOR DRAIN,
REFER TO PLUMBING
FLOOR TILE ON THINSET
CEMENTITOUS BOND COAT
FLOOR TILE ON THINSET
CEMENTITIOUS BOND
COAT
WATERPROOFING/CRACK
ISOLATION MEMBRANE
EXISTING FLOOR SLAB
STAINLESS STEEL COVED
PROFILE (SCHLUTER
DILEX-EHK OR EQUAL)
WALL TILE ON THINSET
CEMENTITOUS BOND
COAT
WATERPROOFING
MEMBRANE
COATED GLASS MAT
WATER-RESISTANT
GYPSUM BACKER BOARD
STRUCTURAL CONCRETE
FILL AT EXISTING
DEPRESSED SLAB
EPOXY GROUT
STAINLESS STEEL ROUNDED
CORNER TRIM (SCHLUTER
RONDEC OR EQUAL)
WALL TILE
CEMENTITIOUS BOND COAT
WATERPROOFING MEMBRANE
COATED GLASS MAT WATER-
RESISTANT GYPSUM BACKER
BOARD
SCHEDULED PARTITION, SEE PLANS
EPOXY GROUT
FLOOR TILE ON THINSET
CEMENTITOUS BOND COAT
STRUCTURAL CONCRETE
FILL AT EXISTING
DEPRESSED SLAB
EDGE OF SLAB
DEPRESSION
EXISTING FLOOR SLAB
EPOXY GROUT
DOOR
ZINC DIVIDER STRIP
EPOXY SLOPE AND FILL
MORTAR
WATERPROOFING
MEMBRANE
EPOXY POURED
TERRAZZO
FLOOR TILE ON THINSET
CEMENTITOUS BOND COAT
STRUCTURAL CONCRETE
FILL AT EXISTING
DEPRESSED SLAB
EDGE OF SLAB
DEPRESSION
EXISTING FLOOR SLAB
EPOXY GROUT
DOOR
SINGLE PIECE, 1/2" TH SOLID SURFACE
THRESHOLD W/ 1/8" BEVELED EDGES,
BOTH SIDES; COLOR: AVONITE -
"SILVER COMET" 8585 OR SIMILAR
EPOXY SLOPE AND FILL
MORTAR
WATERPROOFING
MEMBRANE
EPOXY POURED
TERRAZZO
EPOXY SLOPE AND
FILL MORTAR
EXISTING FLOOR SLAB
EPOXY POURED
TERRAZZO
DOOR
STATIC DISSIPATIVE TILE
ON MANUFACTURER'S
RECOMMENDED
ADHESIVE
TAPERED STAINLESS
STEEL TRIM (SCHLUTER
RENO-U OR EQUAL)
EPOXY SLOPE AND
FILL MORTAR
EXISTING FLOOR SLAB
EPOXY POURED
TERRAZZO
DOOR
SEALED CONCRETE
TAPERED STAINLESS
STEEL TRIM (SCHLUTER
RENO OR EQUAL)
FLOOR TILE ON THINSET
CEMENTITOUS BOND COAT
WATERPROOFING
MEMBRANE
EXISTING FLOOR SLAB
EPOXY GROUT
DOOR
TAPERED STAINLESS
STEEL TRIM (SCHLUTER
RENO OR EQUAL)
RUBBER SHEET FLOORING
EXISTING FLOOR SLAB
DOOR
CARPET TILE
EPOXY SLOPE AND
FILL MORTAR
EPOXY POURED
TERRAZZO
TAPERED STAINLESS
STEEL TRIM (SCHLUTER
RENO-U OR EQUAL)
POURED EPOXY TERRAZZO
EXISTING FLOOR SLAB
SCHEDULED PARTITION;
SEE PARTITION TYPE FOR
MORE INFO.
FINISH TOP AND FACE OF
PRECAST TERRAZZO
COVE BASE
EPOXY SLOPE AND MORTER FILL
EPOXY SETTING BED
R 3 /4
1/2"
EXTRUDED END TRIM
4 INSERT ALUMINUM
RAIL
CONNECT TPE
/2
2 1/2" 1 1/2"3/4"
ABRASIVE CARPET
INSERT
POURED EPOXY TERRAZZO
EXISTING FLOOR SLAB
ALUMINUM TAPERED EDGE
BANDING
EPOXY SLOPE AND
FILL MORTAR
EXISTING FLOOR SLAB
EPOXY POURED
TERRAZZO
DOOR
STAINLESS STEEL TRIM
(SCHLUTER SCHIENE OR
EQUAL)
EPOXY POURED
TERRAZZO
EPOXY SLOPE AND FILL
MORTAR
EPOXY SLOPE AND
FILL MORTAR
EXISTING FLOOR SLAB
EPOXY POURED
TERRAZZO
DOOR
EPOXY RESINOUS FLOOR
TAPERED STAINLESS
STEEL TRIM (SCHLUTER
RENO-U OR EQUAL)
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
J K
J K
E W
E W
BIM 360://US-USACE-F5Y69202-Lee & Sherman Barracks Renovation/LB-81721A-18-CENTRAL.rvt
7/21/2021 3:43:04 PM
I-501
LEE
M
IS
C E
L L A
N E
O U
S D
E T
A
IL
S
W E
S T
P O
IN
T
N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N
E W
Y O
R K
N
Y
J
U L Y
W D
S D
RTA SUBMISSION
L E
E B
A R
R A
C K
S
W D
S F
P N
3" = 1'-0"1
TOILET ROOM FLOOR ASSEMBLY - TYPICAL
3" = 1'-0"2
TOILET ROOM FLOOR ASSEMBLY - AT DRAIN
3" = 1'-0"3
COVE TRIM AT TILE WALL & FLOOR
3" = 1'-0"4
OUTSIDE 90º CORNER TILE TRIM
3" = 1'-0"6
TILE (T) TO POURED TERRAZZO (TZ) - TOILET ROOMS
3" = 1'-0"7
TERRAZZO TILE (TZ) TO POURED TERRAZZO
(TZ) - SHOWER ROOMS
3" = 1'-0"8
POURED TERRAZZO (TZ) TO RESILIENT FLOOR (RF)
3" = 1'-0"9
POURED TERRAZZO (TZ) TO SEALED CONCRETE (SC)
3" = 1'-0"10
TILE (T) TO RESILIENT FLOOR (RF)
3" = 1'-0"12
POURED TERRAZZO (TZ) TO CARPET TILE (C)
3" = 1'-0"13
TERRAZZO COVE BASE @ POURED TERRAZZO
3" = 1'-0"14
DETAIL @ SURFACE MOUNTED WALK-OFF MAT
3" = 1'-0"5
POURED TERRAZZO (TZ) TO POURED TERRAZZO (TZ)
3" = 1'-0"11
POURED TERRAZZO (TZ) TO EPOXY RESINOUS FLOOR (E)
POURED EPOXY TERRAZZO
EXISTING FLOOR SLAB
SCHEDULED PARTITION;
SEE PARTITION TYPE FOR
MORE INFO.
PRECAST TERRAZZO
COVE BASE
RIGID SHEET INSTALLED
BUTT-JOINT AT TOP OF BASE.
SEAL WITH COLOR MATCHED
CAULK.
RIGID SHEET, AS SPECIFIED,
FULLY ADHERED TO GWB
FINISHED FLOOR.
SEE FINISH SCHED FOR MORE INFO.
EXISTING FLOOR SLAB
SCHEDULED PARTITION;
SEE PARTITION TYPE FOR
MORE INFO.
RESILIENT COVE BASE
1/4" OVERLAP
RIGID SHEET, AS SPECIFIED.
FULLY ADHERED TO GWB
/4
SCHEDULED PARTITION;
SEE PARTITION TYPE FOR
MORE INFO.
MIN. 20 GA. VERTICAL / HORIZONTAL
STEEL STUD AND STRAPPING
(BY OTHERS)
1/4-20 X 5" S/S RD HD BOLT
W/ TOGGLE AND LOCK WASHER
32" [812.8mm] O.C. MAX.
ALUMINUM RETAINER
HANDRAIL COVER
MOUNTING BRACKET
1 1/2"
3"
/4
/2
VINYL J-CAP, ALIGNED W/
TOP OF HANDRAIL
RIGID SHEET, AS SPECIFIED.
FULLY ADHERED TO GWB
STAINLESS STEEL
CORNER GUARD
NOSE RADIUS
FACTORY SUPPLIED
ADHESIVE
S…
This is the start of the file's text. The full file is on GovTribe.