Attachment 27b- CH50091-2P Attachment 5b Conceptual Construction Plans AD.pdf

PDF 276 KB Posted

Attached to
Fort Gordon MATOC IDIQ for Minor Construction, Repair and Alteration
Solicitation number
W9124920R0020
Issued by

About this file

This document includes a demolition plan and specifications for renovations at Building 14500 at Fort Gordon, Georgia, as well as details for a related solicitation.

The demolition plan outlines areas for removal including walls, windows, doors, flooring, casework and site elements to prepare the building for renovations. It provides notes on protection of existing structures, hazardous material abatement procedures, and coordination with ongoing building operations.

Solicitation W9124920R0020 is for an Indefinite-Delivery Indefinite-Quantity Multiple Award Task Order Contract for minor construction, repair and alteration projects at Fort Gordon. Offerors are invited to attend a site visit on July 28th or 29th 2020 with a maximum of two people per firm. The solicitation closes on August 14th 2020. The agency is the Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Eustis.

View the file

Other files

File Type Posted
ATTACHMENT 38 - CONTRACTOR SUBMITTED QUESTIONS AND GOVERNMENT PROVIDED ANSWERS LAST ROUND OF QUESTIONS.pdf PDF
ATTACHMENT 39 - Consolidated Copy of Solicitation through Amendment 5.pdf PDF
W9124920R0020 AMENDMENT 0006.pdf PDF
Attachment 24- CH50091-2P Attachment 4 Experience Information.doc DOC document
Attachment 20- CH50091-2P Renovate Expand Bldg-29608 SOW 20Aug20_.pdf PDF
Attachment 25 -CH50091-2P Attachment 5a Conceptual Design Analysis 20Aug....pdf PDF
Attachment 27g- CH50091-2P Attachment 5b Conceptual Construction Plans LS.pdf PDF
Attachment 26-CH50091-2P Attachment 5a Design Analysis 20Aug20.docx DOCX document
Attachment 27e- CH50091-2P Attachment 5b Conceptual Construction Plans I.pdf PDF
Attachment 11- Scope of Work_MATOC 17Aug20.pdf PDF
W9124920R0020 AMENDMENT 0005.pdf PDF
Attachment 27h- CH50091-2P Attachment 5b Conceptual Construction Plans M- (2).pdf PDF
Attachment 27c- CH50091-2P Attachment 5b Conceptual Construction Plans EP.pdf PDF
Attachment 27d- CH50091-2P Attachment 5b Conceptual Construction Plans FA.pdf PDF
Attachment 27i- CH50091-2P Attachment 5b Conceptual Construction Plans M-.pdf PDF
Attachment 36 - MATOC_Contractor Questions and Answers_FINAL.pdf PDF
Attachment 22-CH50091-2P Attachment 2 Proposal Format.docx DOCX document
Attachment 27f- CH50091-2P Attachment 5b Conceptual Construction Plans I-.pdf PDF
Attachment 37 - Site Visit sign in_Redacted.pdf PDF
Attachment 27a- CH50091-2P Attachment 5b Conceptual Construction Plans A.pdf PDF
Attachment 21- CH50091-2P Attachment 1 Task Order Price Schedule Rev1.docx DOCX document
Attachment 23- CH50091-2P Attachment 3 Experience Overview.doc DOC document
W9124920R0020 AMENDMENT 0004.pdf PDF
W9124920R0020 AMENDMENT 0003.pdf PDF
W9124920R0020 AMENDMENT 0002.pdf PDF
Attachment 17 - Past Performance Cover Letter and Assessment Questionnair-REV1.docx DOCX document
W9124920R0020 AMENDMENT 0001.pdf PDF
Attachment 5- Division 01 Specifications_MATOC 10Jun20.pdf PDF
Attachment 16- Example of Package 1.pdf PDF
Attachment 2-Davis-Bacon Act WD GA20200153 Building - Richmond County GA.pdf PDF
Attachment 4-01 33 00 attachment SF1413-13e.pdf PDF
Attachment 6- MATOC QA Plan with Appendices_10Jun20.pdf PDF
Attachment 8- FG Installation Planning Standards_PreFinal 061319.pdf PDF
Attachment 22-CH50091-2P Attachment 2 Proposal Format.docx DOCX document
Attachment 29- Draft RTOP Letter.pdf PDF
Attachment 25- CH50091-2P Attachment 5a Conceptual Design Analysis.pdf PDF
Attachment 1-Davis-Bacon Act WD GA20200275 Highway Georgia.pdf PDF
Attachment 3-01 08 00 Weighted Guidelines.xls XLS spreadsheet
Attachment 11- Scope of Work_MATOC 12Jun20.pdf PDF
Attachment 28- CH50091-2P Attachment 6 As-builts.pdf PDF
Attachment 12- Submital Register.pdf PDF
Attachment 10- Pre-Construction Safety Brief (Updated 2020).pdf PDF
Attachment 20- CH50091-2P Renovate Expand Bldg-29608 SOW Rev1.pdf PDF
Attachment 7- FG Storm Water Permitting Requirements.pdf PDF
Attachment 14- ufc_3_740_05_2010_c1 Construction Cost Est.pdf PDF
Attachment 27- CH50091-2P Attachment 5b Conceptual Construction Plans.pdf PDF
Attachment 19 - Consent Form for the Release of Past Performance.docx DOCX document
Attachment 18 - Specific Relevant Contract Reference Sheets.docx DOCX document
W9124920R0020 FORT GORDON MATOC.pdf PDF
Attachment 23- CH50091-2P Attachment 3 Experience Overview.doc DOC document
Show 40 more

Latest 50 of 57 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F

IR

S T F

L O

O R P

L A

N

D E

M O

L

IT

IO

N

B E

H N

F E

L D

T

C U

R R

A N

B E

H N

F E

L D

T

-- G R

M A

D .d g n

/8

AD101

S Y

M B

O L

D E

S C

R I P

T I O

N B

Y D

A T

E

FORT GORDON, GA. 30905

BLDG. 14500, 527 15TH STREET

ENGINEERING DIVISION

R O

W

C

IL

BUPFO ETA

R

O T

C E

RI

D

S K

FO

RT GORDON, GEORGI

A

F I L

E N

A M

E

F I L

E N

A M

E

1 2 3 4 5 6 7 8

A

B

C

D

E

F

G

H

I V I L

SHEETNUMBER:

PLATE REFERENCE

DRAWING NUMBER:

D A

T E

P R

O J

E

T

N U

M B

E R

S O

L I C I T

A T I O

C O

N T

R A

S I Z

E

P L

S

A L

E

A

O W

N

A R

C H I T

E C

T

P R

O J

E

E

G

E L

E C

T R I C

A L

M E

C H

A N I C

A L

C A

D

20-XX

I

J

O B

R E

Q U I R

E M

E N

T

-J

B

Y A

G O

J

Y A

G O

G

O

D

E P

H E

R D

R E

N O

V A

X

P A

A U

G

C H

P

J

Y A

G O

X

A N

S I

D

(3

R

R D

O N

G A

D I R

E C

T O

R A

P

B L I

W

R K

S

I N

S T

A L

L A

T I

M

N A

G E

M E

M M

A N

D

R

M Y

R R I S

O N

LEGEND

A.

D02.

D01.

REMOVE EXISTING CMU WALL - SHORE EXISTING ROOF

FRAMING AS REQUIRED

D04.

REMOVE EXISTING DOOR AND FRAME

D03.

REMOVE EXISTING WINDOW AND SILL - PREP FOR INFILL

TO MATCH EXISTING

D05.

D06.

D07.

D08. EXISTING FAN COIL UNIT TO REMAIN - PROTECT DURING

DEMOLITION AND CONSTRUCTION

TYP

TYP

0 8 16FT

AD101

FIRST FLOOR PLAN - DEMOLITION

SCALE: 1/8" = 1'-0"

REMOVE EXISTING ACM FLOOR TILE

AND GYP BOARD CEILING

D09.

D10.

REMOVE EXISTING WINDOW , SILL AND PORTION OF WALL TO

ACCEPT NEW HM DOOR AND FRAME

D11.

REMOVE EXISTING CONCRETE STOOP AND STEP

- REFER TO CIVIL DRAWINGS

REMOVE EXISTING CONCRETE WALK

- REFER TO CIVIL DRAWINGS

REMOVE EXISTING CASEWORK AND ALL ATTACHED

COMPONENTS

REMOVE EXISTING 2' HIGH BRICK SITE WALL AND FOUNDATION

- REFER TO CIVIL DRAWINGS

REMOVE PORTION OF EXISTING EXTERIOR WALL - 6" CMU

WITH BRICK VENEER - COORDINATE OPENING SIZE WITH

NEW DOOR/LOUVER

D12. REMOVE ACCORDION OPERABLE PARTITION TRACK AND

HARDWARE

D13. REMOVE EXISTING DOWNSPOUT - PATCH GUTTER OPENING

WITH SIMILAR MATERIAL AND SEAL JOINT

REMOVE EXISTING CERAMIC TILE AT

FLOORING AND WALLS, PLUMBING

FIXTURES, TOILET PARTITIONS, TOILET

ACCESSORIES, AND EXISTING ACM GYP

BOARD CEILING. PREP CONCRETE SLAB

FOR FLOOR LEVELER.

DEMOLITION KEYNOTES

GENERAL NOTES

REFER TO CIVIL DRAWINGS FOR SITE ELEMENTS BEING

REMOVED.

REMOVE WOOD TRIM AT CEILING IN EXISTING CORRIDOR

AND ACTIVITY ROOM.

WOOD BASE IN CORRIDOR TO REMAIN WHERE FEASIBLE.

PROTECT FROM DAMAGE.

REFER TO SECIFICATION SECTION 02 82 14.00 10

"ASBESTOS HAZARD CONTROL ACTIVITIES" FOR REMOVAL

OF HAZARDOUS MATERIALS.

DIMENSIONS SHOWN ON DEMOLITION PLAN ARE APPROXIMATE

AND SHALL BE FIELD VERIFIED.

OWNER WILL OCCUPY PORTIONS OF BUILDING IMMEDIATELY

ADJACENT TO SELECTIVE DEMOLITION AREA. CONDUCT SELECTIVE

DEMOLITION SO OWNER'S OPERATIONS ARE NOT DISRUPTED.

NEATLY CUT OPENINGS & HOLES PLUMB, SQUARE, AND TRUE TO

DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO

DAMAGE CONSTRUCTION TO REMAIN OR ADJOINING CONSTRUCTION.

USE HAND TOOLS OR SMALL POWER TOOLS DESIGNED FOR SAWING

OR GRINDING.

CUT OR DRILL FROM THE EXPOSED OR FINISHED SIDE INTO

CONCEALED SURFACES TO AVOID MARRING EXISTING FINISHED

SURFACES.

VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED

BEFORE STARTING SELECTIVE DEMOLITION OPERATIONS.

EXIST SERVICES/SYSTEMS TO REMAIN: MAINTAIN SERVICES/

SYSTEMS INDICATED TO REMAIN & PROTECT THEM AGAINST

DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS.

TEMPORARY SHORING: PROVIDE & MAINTAIN SHORING, BRACING, &

STRUCTURAL SUPPORTS AS REQUIRED TO PRESERVE STABILITY AND

PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF

CONSTRUCTION AND FINISHES TO REMAIN.

REFER TO SECIFICATION SECTION 02 41 00 "SELECTIVE

DEMOLITION" FOR ADDITIONAL INFORMATION NOT

PROVIDED ON THIS SHEET.

REFER TO 06/A-401

EXISTING CONSTRUCTION TO BE REMOVED

EXISTING CONSTRUCTION TO REMAIN

D01

D01

D02

D03

D06

D06

D09

D04

D04

D07

D07

D05

D06D06

D08

N

4'-0"

9'-8" 8'-4"

D10 D10 D10

D10 D10

D11

D11

D10

90'-2" VIF

B.

C.

6'-8"+/- 7'-8"+/-

/- 6

5'-2"

6"

2'-0"

2'-4"

3'-4" 7'-8"

D.

D12

E.

D13

F.

G.

H.

I.

J.

K.

L.

21'-5 1/2 " +/-

D10 D10

D10 D10

D10

CARPET AND VCT TILES UNDER CARPET

CARPET AND VCT TILES UNDER CARPET

CARPET AND VCT TILES UNDER CARPET

CARPET AND

VCT TILES

UNDER

CARPET

CARPET AND

VCT TILES

UNDER

CARPET

CARPET AND

VCT TILES

UNDER

CARPET

CARPET AND

VCT TILES

UNDER

CARPET

CARPET AND

VCT TILES

UNDER

CARPET

CARPET AND

VCT TILES

UNDER

CARPET

CARPET AND VCT TILES UNDER CARPET

REMOVE EXISTING DOOR LEAF AND HARDWARE- PREP FOR

NEW DOOR LEAF AND HARDWARE.

File details come from the government source that posted it. Updated .