S-121C TRUSS BOTTOM CHORD PLAN -AREA C.pdf

PDF 162 KB Posted

Attached to
DLA Fitness Center Renovation
Solicitation number
W9123620B2011
Issued by

About this file

This pre-solicitation notice and related documents outline requirements for a firm-fixed-price construction contract to renovate the fitness center at the Defense Supply Center Richmond in Virginia. The project includes offices, wellness areas, racquetball courts, a gymnasium with regulation basketball court and bleachers, locker rooms with showers and amenities. The contract value is estimated between $5-10 million. The solicitation will be issued on April 9th, with proposals due May 7th and award by mid-June. This is a 100% small business set-aside using definitive responsibility criteria. The NAICS code is 236220 and size standard is $39.5 million. The period of performance is 450 days after notice to proceed. The contract will require payment and performance bonds. Options may be included. The Army Corps of Engineers Norfolk District will award a single contract.

View the file

Other files

File Type Posted
B.01.02_Abstract of Offers Page 2 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Revised Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Abstract of Offers Page 2 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
B.01.02_Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
118ECE908 AMDT 004 DRAWINGS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 21 13 dated 082017 updated 05142020 10 pages.pdf PDF
20-B-2011 Amend 0004.pdf PDF
118ECE908 AMDT 004 SPECIFICATIONS dated 05142020 1556 pages.pdf PDF
118ECE908 AMDT 004 A 401 ENLARGED LOCKER ROOM RESTROOM PLANS AND TYPICAL ELEVATIONS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 51 13 dated 05201 updated 05142020 1 6 pages.pdf PDF
Typed Site Visit Sign In Sheet for DLA Fitness Center 04222020.pdf PDF
W91236-20-B-2011 Amendment 3.pdf PDF
118ECE908 AMDT 002 11 66 23.pdf PDF
W9123620B0011 Amendment 2.pdf PDF
118ECE908 AMDT 002 DRAWINGS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111A REFLECTED CEILING PLAN AREA A.pdf PDF
118ECE908 AMDT 002 A111B REFLECTED CEILING PLAN AREA B.pdf PDF
118ECE908 AMDT 002 08 41 13.pdf PDF
118ECE908 AMDT 002 A111C REFLECTED CEILING PLAN AREA C.pdf PDF
118ECE908 AMDT 002 SPECIFICATIONS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111D REFLECTED CEILING PLAN AREA D.pdf PDF
118ECE908 AMDT 002 FF AND E BINDER 05MAY2020.pdf PDF
118ECE908 AMDT 002 I 101B FINISH PLAN AREA B.pdf PDF
118ECE908 AMDT 002 A002 PARTITION TYPES.pdf PDF
118ECE908 AMDT 002 A101B FLOOR PLAN AREA B.pdf PDF
118ECE908 AMDT 002 10 23 10.pdf PDF
118ECE908 AMDT 002 A101C FLOOR PLAN AREA C.pdf PDF
S-302 SECTIONS AND DETAILS -II.pdf PDF
S-201 FRAMING ELEVATIONS AND DETAILS.pdf PDF
S-301 SECTIONS AND DETAILS -I.pdf PDF
S-501 TYPICAL STRUCTURAL DETAILS -I.pdf PDF
S-001 GENERAL STRUCTURAL NOTES.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
S-101 OVERALL FOUNDATION PLAN.pdf PDF
A.01.13_118ECE908 AMDT 002 33 40 00 dated 022010 11 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 GC002 dated 04292020 1 page.pdf PDF
A.01.13_118ECE908 AMDT 002 01 11 00.00 50 dated 022013 14 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 CG 100 dated 04292020 1 page.pdf PDF
20-B-2011 Amendment 1.pdf PDF
A.01.13_118ECE908 AMDT 002 CU 101 dated 04292020 1 page.pdf PDF
A.01.13_118ECE908 AMDT 002 CG 102 dated 04292020 1 page.pdf PDF
G.01.47_PreBid Sign In Sheet for Fitness Center 04222020.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
I101C FLOOR FINISH PLAN -AREA C.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
Show 40 more

Latest 50 of 76 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

7 8 9 10 11 12 13

G

F

E

D

C

B

A

C1

S-301

C2

S-301

BASKETBALL GOAL SUPPORTS

E L

E V

A T

IO

N

F

.V

B /S

T L

E L

E V

A T

IO

N

F

.V

B /S

T L

M A

T C

H L

IN

E S

E E

/S

-1 A

MATCHLINE

SEE 1/S-111D

20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0"

E X

IS

T

H

IG

H R

O O

F S

T L T

R U

S S

T

Y P

S

E E

N O

T E

C

TYP

E X

IS

T

L O

W R

O O

F S

T L T

R U

S S

T

Y P

EXIST STL ANGLE

HORIZ. X-BRACING,

TYP

E X

IS

T

L O

W R

O O

F S

T L T

R U

S S

T

Y P

EXIST STL TRUSS EXIST STL TRUSS EXIST STL TRUSS

EXIST STL TRUSS EXIST STL TRUSS EXIST STL TRUSS

EXIST 2L BRACE EXIST 2L BRACE EXIST 2L BRACE EXIST 2L BRACE

EXIST 2L BRACE EXIST 2L BRACE EXIST 2L BRACE EXIST 2L BRACE

EXIST STL TRUSS EXIST STL TRUSS EXIST STL TRUSS EXIST STL TRUSS EXIST STL TRUSS EXIST STL TRUSS

EXIST 2L BRACEEXIST 2L BRACEEXIST 2L BRACE EXIST 2L BRACEEXIST 2L BRACE EXIST 2L BRACE

EXIST STL ANGLE

HORIZ. X-BRACING,

TYP

EXIST 2L BRACE

EXIST 2L BRACE

EXIST 2L BRACE

EXIST 2L BRACE

E X

IS

T

L O

W R

O O

F S

T L T

R U

S S

T

Y P

E X

IS

T

L O

W R

O O

F S

T L T

R U

S S

T

Y P

E X

IS

T

W X

T O

P C

H O

R D

E X

IS

T

W X

T O

P C

H O

R D

E X

IS

T

W X

T O

P C

H O

R D

E X

IS

T

W X

T O

P C

H O

R D

E X

IS

T

W X

T O

P C

H O

R D

W 8X

W 8X

W 8X

W 8X

W 8X

W8X18

W8X18

W8X18

W8X18

W 8X

W 8X

W 8X

5' - 4 3/4" 6' - 2 3/4"

4' - 4 1/8" 5' - 10 3/4" 5' - 4 3/4" 4' - 4 1/4"

C1

S-301

C2

S-301

B3

S-201

TYP

A. ALL EXISTING CONSTRUCTION SHALL BE FIELD

VERIFIED PRIOR TO CONSTRUCTION. CONTACT

EOR PRIOR TO BEGINNING CONSTRUCTION IF

CONDITIONS VARY FROM DRAWINGS.

B. ALL LOADS SHALL BE HUNG FROM WITHIN SIX

INCHES OF TRUSS PANEL POINTS OR FROM

ROOF CHANNELS, UNO. DO NOT HANG LOADS

FROM EXISTING HORIZONTAL BRACING

MEMBERS.

C. EXISTING HIGH ROOF TRUSS BOTTOM CHORD

IS A 2L4 X 3 X 5/16 X 3/8 GAP (OVERALL

HORIZONTAL WIDTH = 8 3/8"). FIELD VERIFY

PRIOR TO GIRDER CLAMP FABRICATION.

D. * INDICATES DIMENSIONS TO BE VERIFIED W/

MANUFACTURER OF EQUIPMENT PROVIDED.

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O L K

D

IS

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

E R

W -1

-R

-0

W -1

-R

-0

S-121C

T R

U S

S B

O T

T O

M C

H O

R D

P L A

N

A R

E A

C

F

IL

E N

U M

B E

R

P G

IE

S

S E

L

K P

E R

E Z

P M

U L L

P M

U L L

BAY GBAY F

KEY PLAN

C

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

SCALE: 1/8" = 1'-0"

A1

TRUSS BOTTOM CHORD PLAN - AREA C

REFERENCE KEYNOTES:

GENERAL NOTES:

014 EXISTING BRICK WALL TO REMAIN.

015 EXISTING STEEL ROOF FRAMING TO REMAIN.

021 DIVIDER CURTAIN SUSPENDED FROM EXISTING

ROOF CHANNEL FRAMING, SEE ARCH.

022 BASKETBALL GOALS SUSPENDED FROM

EXISTING FRAMING, SEE ARCH.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

-2

-2

File details come from the government source that posted it. Updated .