118ECE908 AMDT 002 A111C REFLECTED CEILING PLAN AREA C.pdf

PDF 573 KB Posted

Attached to
DLA Fitness Center Renovation
Solicitation number
W9123620B2011
Issued by

About this file

This pre-solicitation notice is for a firm-fixed-price design-bid-build construction contract to renovate Building 32, Bays F-G at the Defense Supply Center Richmond for a new fitness center. The project scope includes offices, a wellness center, racquetball courts, gymnasium with regulation basketball court and bleachers, locker rooms with showers and restrooms, and storage areas. The contract value is estimated between $5-10 million. The solicitation will be issued on April 9, 2020 with proposals due May 7, 2020. This is a 100% small business set-aside using NAICS 236220 and a size standard of $39.5 million. The Army Corps of Engineers Norfolk District will award a single contract with a 450-day period of performance and optional items included. Interested parties must register in SAM and check the website regularly for amendments to the solicitation issued only in beta.sam.gov.

View the file

Other files

File Type Posted
B.01.02_Abstract of Offers Page 2 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Revised Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Abstract of Offers Page 2 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
B.01.02_Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
118ECE908 AMDT 004 DRAWINGS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 21 13 dated 082017 updated 05142020 10 pages.pdf PDF
20-B-2011 Amend 0004.pdf PDF
118ECE908 AMDT 004 SPECIFICATIONS dated 05142020 1556 pages.pdf PDF
118ECE908 AMDT 004 A 401 ENLARGED LOCKER ROOM RESTROOM PLANS AND TYPICAL ELEVATIONS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 51 13 dated 05201 updated 05142020 1 6 pages.pdf PDF
Typed Site Visit Sign In Sheet for DLA Fitness Center 04222020.pdf PDF
W91236-20-B-2011 Amendment 3.pdf PDF
118ECE908 AMDT 002 11 66 23.pdf PDF
W9123620B0011 Amendment 2.pdf PDF
118ECE908 AMDT 002 DRAWINGS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111A REFLECTED CEILING PLAN AREA A.pdf PDF
118ECE908 AMDT 002 A111B REFLECTED CEILING PLAN AREA B.pdf PDF
118ECE908 AMDT 002 08 41 13.pdf PDF
118ECE908 AMDT 002 SPECIFICATIONS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111D REFLECTED CEILING PLAN AREA D.pdf PDF
118ECE908 AMDT 002 FF AND E BINDER 05MAY2020.pdf PDF
118ECE908 AMDT 002 I 101B FINISH PLAN AREA B.pdf PDF
118ECE908 AMDT 002 A002 PARTITION TYPES.pdf PDF
118ECE908 AMDT 002 A101B FLOOR PLAN AREA B.pdf PDF
118ECE908 AMDT 002 10 23 10.pdf PDF
118ECE908 AMDT 002 A101C FLOOR PLAN AREA C.pdf PDF
S-302 SECTIONS AND DETAILS -II.pdf PDF
S-201 FRAMING ELEVATIONS AND DETAILS.pdf PDF
S-301 SECTIONS AND DETAILS -I.pdf PDF
S-501 TYPICAL STRUCTURAL DETAILS -I.pdf PDF
S-001 GENERAL STRUCTURAL NOTES.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
S-121C TRUSS BOTTOM CHORD PLAN -AREA C.pdf PDF
S-101 OVERALL FOUNDATION PLAN.pdf PDF
A.01.13_118ECE908 AMDT 002 33 40 00 dated 022010 11 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 GC002 dated 04292020 1 page.pdf PDF
A.01.13_118ECE908 AMDT 002 01 11 00.00 50 dated 022013 14 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 CG 100 dated 04292020 1 page.pdf PDF
20-B-2011 Amendment 1.pdf PDF
A.01.13_118ECE908 AMDT 002 CU 101 dated 04292020 1 page.pdf PDF
A.01.13_118ECE908 AMDT 002 CG 102 dated 04292020 1 page.pdf PDF
G.01.47_PreBid Sign In Sheet for Fitness Center 04222020.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
I101C FLOOR FINISH PLAN -AREA C.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
Show 40 more

Latest 50 of 76 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

E

E

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

ET

SS

C

C

C C

SSSS

C

C

REFLECTED CEILING LEGEND

EXIT LIGHT - CEILING

2' x 2' SUSPENDED

ACOUSTIC CEILING TILES

GYPSUM BOARD CEILING

2 X 4 LIGHT FIXTURE

SUSPENDED LIGHT FIXTURE

RETURN AIR GRILLE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

CEILING HEIGHT TAG

SD

S

SMOKE DETECTOR

SPEAKER

8'-0"

2' x 2' SUSPENDED

CEILING CLOUD W/MESH

STROBE

WOOD CEILING

4' X 8' CEMENTITIOUS

WOOD FIBER ACOUSTICAL

CEILING PANELS

1 X 4 LIGHT FIXTURE

RECESSED LIGHT FIXTURE

RECESSED DOWN LIGHT

PORCELAIN TILE CEILING

CEILING FAN

4X8 T&G CEILING PANEL

A. CENTER CEILING GRID IN ROOM UNLESS SHOWN

OTHERWISE ON REFLECTED CEILING PLAN.

B. CENTER FIXTURES, MECHANICAL DIFFUSERS,

MECHANICAL GRILLES AND SPRINKLER HEADS IN

SUSPENDED ACOUSTICAL CEILING TILE SYSTEM

PANELS.

C. ALL CEILING MOUNTED ITEMS ARE SHOWN FOR

COORDINATION PURPOSES ONLY.

D. SEE ELECTRICAL DRAWINGS FOR LIGHT FIXTURE

AND SPECIAL SYSTEM TYPES.

E. SEE MECHANICAL DRAWINGS FOR DIFFUSER AND

GRILLE TYPES.

F. SEE FIRE PROTECTION FOR SPRINKLER TYPES.

SEE TELECOMMUNICATION AND FIRE PROTECTION

SYSTEMS FOR ADDITIONAL INFORMATION OF

CEILING MOUNTED DEVICES.

G. ALL RCP DIMENSIONS ARE CLEAR FINISHED

DIMENSIONS, UNLESS OTHERWISE NOTED.

H. REFER TO FINISH SCHEDULE FOR CEILING TYPES

AND HEIGHTS NOT INDICATED ON THE REFLECTED

CEILING PLANS.

I. ALL GYPSUM BOARD CEILING WITHIN 4'-0" OF

PERIMETER SHALL BE MOISTURE RESISTANT.

J. SMOKE AND HEAT DETECTORS TO BE GREATER

THAN 3'-0" FROM MECHANICAL DIFFUSERS.

RCP GENERAL NOTES:

7 8 9 10 11 12 13

A

B

C

D

E

F

G

10' - 0" 10' - 0"

10' - 0"

10' - 0"

10' - 0"10' - 0"

EXISTING BOILER

ROOM

G113

EXISTING

TELECOM

G110

EXISTING

MECHANICAL

G108

EXISTING

ELECTRICAL

G107

STORAGE

G106

GYMNASIUM

G111

WOMEN

G116

MEN

G118

JAN.

G117

THERAPY AREA

G121

STORAGE

G119

RELAXATION

ROOM

G123

PERSONAL

TRAINER

G124

RELAXATION

ROOM

G122

STORAGE

G120

MECHANICAL

G114

CORRIDOR

G112

VESTIBULE

G115

CORR.

G121A

STORAGE

G109

MECH

G127

MECH

G128

109109

12' - 0" 12' - 0" 10' - 0" 10' - 0"

112112

2' - 3" 12' - 0"

2' - 2"

6' - 4" 6' - 0" 21' - 0" 6' - 0" 22' - 7" 6' - 0" 32' - 5" 6' - 0" 13' - 0"

112112

10' - 0"

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O L K

D

IS

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

E R

W -1

-R

-0

W -1

-R

-0

A-111C

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

C K

.F E

L T

O N

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

SCALE : 1/8" = 1'-0"A1 REFLECTED CEILING PLAN - AREA C

BAY GBAY F

KEY PLAN

C

0 8' 16' 32'

GRAPHIC SCALE

PLAN NORTH

REFERENCE KEYNOTES:

108 EXPOSED STRUCTURE ABOVE. PAINT ALL

EXPOSED STRUCTURE AND PIPES.

109 STRUCTURE MOUNTED RETRACTABLE

BASKETBALL GOAL

112 BID OPTION: SUSPENDED CEILING CLOUD

W/MESH

122 EXISTING CEILING. NO WORK.

123 4'-0" X 8'-0" CEMENTITIOUS WOOD FIBER

ACOUSTICAL CEILING PANELS ATTACHED AT

EXISTING STEEL PURLINS. SEE DETAIL C1/A-511

126 ROLL UP GYM DIVIDER CURTAIN. SEE DETAIL

C1/A-521

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

-2

-2

A

M E

N D

M E

N T

-0

-2

File details come from the government source that posted it. Updated .