I101D FLOOR FINISH PLAN -AREA D.pdf
PDF 204 KB Posted
- Attached to
- DLA Fitness Center Renovation
- Solicitation number
- W9123620B2011
About this file
This notice is for a pre-solicitation of a firm-fixed-price construction contract to renovate the Defense Supply Center Richmond Fitness Center. The renovation will include offices, wellness facilities, racquetball courts, a gymnasium, locker rooms, and storage areas. The contract is valued between $5-10 million and will be set aside for small businesses using NAICS code 236220 with a size standard of $39.5 million. The solicitation will be issued on April 9, 2020 with proposals due May 7, 2020. The selected contractor must furnish payment and performance bonds and will be responsible for obtaining necessary permits. The work will be performed at Defense Supply Center Richmond and managed by the US Army Corps of Engineers Norfolk District.
View the file
Other files
Show 40 more
Latest 50 of 76 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1985 SF
AEROBICS
G105
401 SF
MARTIAL ARTS
G104
1537 SF
SPINNING
G102
632 SF
STORAGE
G106
375 SF
STORAGE
G103
1181 SF
CORRIDOR
G101
46 SF
VEST.
G100A
137 SF
RISER ROOM
G100B
AWP-1
A W
P -1
FLOOR FINISH LEGEND
ART-1
CPT-1
PC-1
SC-1
TRF-1
WDF-3
TS-6A
TS-6A
TS-3
TS-8
TS-3
TS-3
TS-6A
WS-1
V.I.F.
10' - 0"
V.I.F.
10' - 0"
WS-1
1 1
ACCENT WALL LEGEND
P-X ACCENT WALL PAINT LOCATION
WITH PAINT COLOR CODE. SEE
FINISH LEGEND FOR PAINT COLOR
INFORMATION.
A. REFERENCE ARCHITECTURAL FLOOR PLANS FOR FLOOR
RAMP TRANSITIONS. SEE KEYNOTE 128.
B. REFERENCE SHEET I-601 FOR INTERIOR FINISH LEGEND,
SCHEDULE AND DETAILS.
C. MATCH FINISH OF COVERS FOR RETURN AIR DUCTS, VENTS, &
REGISTERS IN DRYWALL CEILINGS AND WALLS TO ADJACENT
SURFACES.
D. DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL
SURFACES, OPERATING PARTS, OR LABELS.
E. FLOOR FINISH TRANSITIONS TO OCCUR AT CENTERLINE OF
DOOR, UNLESS NOTED OTHERWISE.
F. RESTROOM SHOWERS ARE PRECAST UNITS. SEE FINISH
LEGEND, I-601.
G. WINDOW SILLS TO BE SS-2.
H. BULLNOSE ALL EXPOSED EDGES AND OUTSIDE CORNERS OF
WALL TILE AND BASE.
I. INSIDE MOUNT WS-1 ON ALL INTERIOR WINDOWS. ALL
WINDOWS SHALL RECEIVE SHADES.
J. SLOPE TILED FLOORS TO FLOOR DRAINS AS REQUIRED.
FINISH PLAN GENERAL NOTES:
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
I101D
F L O
O R
F
IN
IS
H
P L A
N
A R
E A
D K
.B A
R K
E R
C .C
O L E
B .F
O R
E T
B .F
O R
E T
SCALE : 1/8" = 1'-0"A1 FLOOR FINISH PLAN - AREA D
4'0 8' 16'
GRAPHIC SCALE
PLAN NORTH
BAY GBAY F
KEY PLAN
D
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
-2
-2
File details come from the government source that posted it. Updated .