This notice provides information on an upcoming federal construction contract opportunity for the renovation of a fitness center at the Defense Supply Center Richmond in Virginia. The U.S. Army Corps of Engineers Norfolk District intends to award a single firm-fixed-price contract between $5-10 million under a 100% small business set-aside. The solicitation will be issued on April 9th, 2020, with proposals due on May 7th, 2020. The work involves renovating Building 32, Bays F-G to relocate an existing fitness center and includes offices, a wellness center, racquetball courts, gymnasium, locker rooms, and other functional spaces. The period of performance is 450 days after notice to proceed. Interested parties must register in the System for Award Management and check the website regularly for any amendments, as notifications will only be posted electronically.
View the file
Other files
Show 40 more
Latest 50 of 76 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STANDARD CLEVIS
HANGER AND ROD
TREATED WOOD BLOCK SIZED TO
MATCH PIPE INSULATION
GROOVED RIGID COUPLINGS
GROOVED RIGID COUPLING
BUTTERFLY VALVE (TYP.)
GROOVED FLEXIBLE COUPLING (TYP.)
CHECK VALVE
GROOVED CONCENTRIC REDUCER WITH
FLANGE ADAPTER
ANCHOR PUMP BASE TO CONCRETE FLOOR.
GROUT PUMP BASE SOLID.
CONCRETE HOUSEKEEPING PAD.
DRAIN VALVE
SUCTION DIFFUSER WITH SUPPORT LEG. IF INLET
DOES NOT MATCH SYSTEM PIPE SIZE PROVIDE
FLANGED INCREASER.
RR
R R
R
F
F
F
F
F
F
GROOVED PIPE OPTION
BALANCING VALVE (ONLY REQUIRED IF PUMP
DOES NOT HAVE A VFD)
F
F
THREE PORT TRUMPET VALVE
SUCTION DIFFUSER WITH SUPPORT LEG. IF
INLET DOES NOT MATCH SYSTEM PIPE SIZE
PROVIDE FLANGED INCREASER.
DRAIN VALVE
CONCRETE HOUSEKEEPING PAD.
ANCHOR PUMP BASE TO
CONCRETE FLOOR. GROUT BASE
SOLID.
SINGLE GAGE WITH GAGE COCKS AND
UNION PIPED BETWEEN DISCHARGE AND
SUCTION TAPS ON PUMP
FLANGED INCREASER (TYP)
CHECK VALVE
PUMP SUCTION PIPE
DOUBLE, SPHERICAL NEOPRENE FLEXIBLE CONNECTION
WITH FLANGED ENDS (TYP). DO NOT ALLOW WEIGHT OF
PIPE TO BEAR ON FLEXIBLE CONNECTION. DO NOT USE
CONNECTION FOR PIPE MISALIGNMENT.
BUTTERFLY VALVE (TYP)
PUMP DISCHARGE PIPE
WOOD BLOCK SIZED TO MATCH PIPE
INSULATION
STANDARD CLEVIS
HANGER AND ROD
WELDED PIPE OPTION
BALANCING VALVE (ONLY REQUIRED IF THE
PUMP DOES NOT HAVE A VFD)
THREE PORT TRUMPET VALVE
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
M-503
M E
C H
A N
IC
A
L D
E T
A
IL
S K
M
IL
L E
R
A S
C H
N U
R
M B
E H
R M
A N
N
M B
E H
R M
A N
N
SCALE : NTSA1 BASE MOUNTED PUMP DETAIL-GROOVED
SCALE : NTSA2 BASE MOUNTED PUMP DETAIL-WELDED
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
-2