About this file

This package includes floor finish plans and specifications for renovating a fitness center at the Defense Supply Center Richmond in Virginia. The Army Corps of Engineers Norfolk District will award a fixed-price construction contract between $5-10 million to renovate Building 32 for the new fitness center. The relocation project scope includes offices, wellness areas, racquetball courts, gymnasium, locker rooms, and support spaces. The pre-solicitation notice states the 100% small business set-aside will use sealed bidding and definitive responsibility criteria. The solicitation will be issued on April 9th and bids are due by May 7th, with a notice to proceed of 450 days. Offerors must register in SAM and the IFB will be available at beta.sam.gov, where any amendments will also be posted.

View the file

Other files

File Type Posted
B.01.02_Abstract of Offers Page 2 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Revised Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Abstract of Offers Page 2 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
B.01.02_Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
118ECE908 AMDT 004 DRAWINGS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 21 13 dated 082017 updated 05142020 10 pages.pdf PDF
20-B-2011 Amend 0004.pdf PDF
118ECE908 AMDT 004 SPECIFICATIONS dated 05142020 1556 pages.pdf PDF
118ECE908 AMDT 004 A 401 ENLARGED LOCKER ROOM RESTROOM PLANS AND TYPICAL ELEVATIONS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 51 13 dated 05201 updated 05142020 1 6 pages.pdf PDF
Typed Site Visit Sign In Sheet for DLA Fitness Center 04222020.pdf PDF
W91236-20-B-2011 Amendment 3.pdf PDF
118ECE908 AMDT 002 11 66 23.pdf PDF
W9123620B0011 Amendment 2.pdf PDF
118ECE908 AMDT 002 DRAWINGS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111A REFLECTED CEILING PLAN AREA A.pdf PDF
118ECE908 AMDT 002 A111B REFLECTED CEILING PLAN AREA B.pdf PDF
118ECE908 AMDT 002 08 41 13.pdf PDF
118ECE908 AMDT 002 A111C REFLECTED CEILING PLAN AREA C.pdf PDF
118ECE908 AMDT 002 SPECIFICATIONS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111D REFLECTED CEILING PLAN AREA D.pdf PDF
118ECE908 AMDT 002 FF AND E BINDER 05MAY2020.pdf PDF
118ECE908 AMDT 002 A002 PARTITION TYPES.pdf PDF
118ECE908 AMDT 002 A101B FLOOR PLAN AREA B.pdf PDF
118ECE908 AMDT 002 10 23 10.pdf PDF
118ECE908 AMDT 002 A101C FLOOR PLAN AREA C.pdf PDF
S-302 SECTIONS AND DETAILS -II.pdf PDF
S-201 FRAMING ELEVATIONS AND DETAILS.pdf PDF
S-301 SECTIONS AND DETAILS -I.pdf PDF
S-501 TYPICAL STRUCTURAL DETAILS -I.pdf PDF
S-001 GENERAL STRUCTURAL NOTES.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
S-121C TRUSS BOTTOM CHORD PLAN -AREA C.pdf PDF
S-101 OVERALL FOUNDATION PLAN.pdf PDF
A.01.13_118ECE908 AMDT 002 33 40 00 dated 022010 11 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 GC002 dated 04292020 1 page.pdf PDF
A.01.13_118ECE908 AMDT 002 01 11 00.00 50 dated 022013 14 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 CG 100 dated 04292020 1 page.pdf PDF
20-B-2011 Amendment 1.pdf PDF
A.01.13_118ECE908 AMDT 002 CU 101 dated 04292020 1 page.pdf PDF
A.01.13_118ECE908 AMDT 002 CG 102 dated 04292020 1 page.pdf PDF
G.01.47_PreBid Sign In Sheet for Fitness Center 04222020.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
I101C FLOOR FINISH PLAN -AREA C.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
Show 40 more

Latest 50 of 76 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING

TELECOM

F117

JANITOR

F118

LAUNDRY

F119

SAUNA

F116B

WOMEN LOCKER

F116C

MEN LOCKER

F115C

STEAM

F116D

MECH.

F116E

MECH.

F115E

STEAM

F115D

SAUNA

F115B

CORRIDOR

F101B

AWP-1

FLOOR FINISH LEGEND

ART-1

EP-1

PC-1

PC-1/WM-1

PT-4

SC-1

WD-1

TS-11

TS-11

TS-10

TS-10TS-10 TS-7TS-7

TS-10

A3/I-602

P-1

P-1

P-1

A3/I-602

MEN RESTROOM

F115A

MEN SHOWERS

F115F

WOMEN SHOWERS

F116F

A3/I-602

A3/I-602

A3/ I-602

WOMEN

RESTROOM

F116A

P-1

A3/I-602P-1

P-1 A3/I-602

A3/I-602

(ALL WALLS)

P-1

A. REFERENCE ARCHITECTURAL FLOOR PLANS FOR FLOOR

RAMP TRANSITIONS. SEE KEYNOTE 128.

B. REFERENCE SHEET I-601 FOR INTERIOR FINISH LEGEND,

SCHEDULE AND DETAILS.

C. MATCH FINISH OF COVERS FOR RETURN AIR DUCTS, VENTS, &

REGISTERS IN DRYWALL CEILINGS AND WALLS TO ADJACENT

SURFACES.

D. DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL

SURFACES, OPERATING PARTS, OR LABELS.

E. FLOOR FINISH TRANSITIONS TO OCCUR AT CENTERLINE OF

DOOR, UNLESS NOTED OTHERWISE.

F. RESTROOM SHOWERS ARE PRECAST UNITS. SEE FINISH

LEGEND, I-601.

G. WINDOW SILLS TO BE SS-2.

H. BULLNOSE ALL EXPOSED EDGES AND OUTSIDE CORNERS OF

WALL TILE AND BASE.

I. INSIDE MOUNT WS-1 ON ALL INTERIOR WINDOWS. ALL

WINDOWS SHALL RECEIVE SHADES.

J. SLOPE TILED FLOORS TO FLOOR DRAINS AS REQUIRED.

FINISH PLAN GENERAL NOTES:

WALL FINISH LEGEND

P-X WALL FINISH LOCATION

WITH FINISH CODE. SEE

FINISH LEGEND FOR MORE

INFORMATION.

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O L K

D

IS

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

E R

W -1

-R

-0

W -1

-R

-0

I101B

F L O

O R

F

IN

IS

H

P L A

N

A R

E A

B K

.B A

R K

E R

C .C

O L E

B .F

O R

E T

B .F

O R

E T

SCALE : 1/8" = 1'-0"A1 FLOOR FINISH PLAN - AREA B

0 8' 16' 32'

GRAPHIC SCALE

PLAN NORTH

BAY GBAY F

KEY PLAN

B

M A

R K

D E

S C

R

IP

T I O

N D

A T

E

A

M E

N D

M E

N T

-0

-2

NOTE: TYP. RESTROOM

WALL FINISH PLAN

NOTE: REFERENCE MENS

AREA FOR TYP. WALL

FINISH PLAN

Sheets
I101B - FLOOR FINISH PLAN - AREA B

File details come from the government source that posted it. Updated .