I101C FLOOR FINISH PLAN -AREA C.pdf
PDF 297 KB Posted
- Attached to
- DLA Fitness Center Renovation
- Solicitation number
- W9123620B2011
About this file
This document provides details for a federal construction contract opportunity to renovate the fitness center at the Defense Supply Center Richmond in Virginia. The renovation project includes offices, a wellness center, racquetball courts, fitness modules, a gymnasium with regulation basketball court and bleacher seating, men's and women's locker rooms with lockers, showers and restrooms, a steam room and sauna. The solicitation number is W9123620B2011 and will use sealed bids following FAR Part 14. The NAICS code is 236220 and size standard is $39.5 million. The period of performance is 450 days from notice to proceed. Bids are due on May 7, 2020 and the contract is valued between $5-10 million, requiring a payment and performance bond. The Army Corps of Engineers Norfolk District will administer the 100% small business set-aside contract.
View the file
Other files
Show 40 more
Latest 50 of 76 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1779 SF
EXISTING BOILER
ROOM
G113
110 SF
EXISTING
TELECOM
G110
440 SF
EXISTING
MECHANICAL
G108
113 SF
EXISTING
ELECTRICAL
G107
632 SF
STORAGE
G106
7010 SF
GYMNASIUM
G111
260 SF
WOMEN
G116
262 SF
MEN
G118
42 SF
JAN.
G117
698 SF
THERAPY AREA
G121
141 SF
STORAGE
G119
233 SF
RELAXATION
ROOM
G123
118 SF
PERSONAL
TRAINER
G124
230 SF
RELAXATION
ROOM
G122
140 SF
STORAGE
G120
799 SF
MECHANICAL
G114
1751 SF
CORRIDOR
G112
101 SF
VESTIBULE
G115
170 SF
CORR.
G121A
187 SF
STORAGE
G109
45 SF
EXISTING RISER
ROOM
G125
62 SF
EXISTING RISER
ROOM
G126
28 SF
MECH
G127
119' - 5 7/8"
MECH
G128
FLOOR FINISH LEGEND
ART-1
CPT-1
LVT-1
PC-1
PT-1
SC-1
TRF-1
WDF-1
WDF-2
P -4
P -3
P-3
P-3
P -3
P-3
P-3
P-3
TS-13
TS-3 TS-14
I-401
A1
TS-6
TS-6
WS-1WS-1 WS-1 WS-1 WS-1
V.I.F.
3' - 6"
V.I.F.
3' - 6"
V.I.F.
3' - 6"
V.I.F.
3' - 6"
A. REFERENCE ARCHITECTURAL FLOOR PLANS FOR FLOOR
RAMP TRANSITIONS. SEE KEYNOTE 128.
B. REFERENCE SHEET I-601 FOR INTERIOR FINISH LEGEND,
SCHEDULE AND DETAILS.
C. MATCH FINISH OF COVERS FOR RETURN AIR DUCTS, VENTS, &
REGISTERS IN DRYWALL CEILINGS AND WALLS TO ADJACENT
SURFACES.
D. DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL
SURFACES, OPERATING PARTS, OR LABELS.
E. FLOOR FINISH TRANSITIONS TO OCCUR AT CENTERLINE OF
DOOR, UNLESS NOTED OTHERWISE.
F. RESTROOM SHOWERS ARE PRECAST UNITS. SEE FINISH
LEGEND, I-601.
G. WINDOW SILLS TO BE SS-2.
H. BULLNOSE ALL EXPOSED EDGES AND OUTSIDE CORNERS OF
WALL TILE AND BASE.
I. INSIDE MOUNT WS-1 ON ALL INTERIOR WINDOWS. ALL
WINDOWS SHALL RECEIVE SHADES.
J. SLOPE TILED FLOORS TO FLOOR DRAINS AS REQUIRED.
FINISH PLAN GENERAL NOTES:
ACCENT WALL LEGEND
P-X ACCENT WALL PAINT LOCATION
WITH PAINT COLOR CODE. SEE
FINISH LEGEND FOR PAINT COLOR
INFORMATION.
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
I101C
F L O
O R
F
IN
IS
H
P L A
N
A R
E A
C K
.B A
R K
E R
C .C
O L E
B .F
O R
E T
B .F
O R
E T
SCALE : 1/8" = 1'-0"A1 FLOOR FINISH PLAN - AREA C
PLAN NORTH
4'0 8' 16'
BAY GBAY F
KEY PLAN
C
TS-5 TS-5TS-10
TS-12
TS-6
TS-6
TS-6
TS-6
TS-6
TS-6
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
-2
-2
File details come from the government source that posted it. Updated .