118ECE908 AMDT 002 A111B REFLECTED CEILING PLAN AREA B.pdf

PDF 412 KB Posted

Attached to
DLA Fitness Center Renovation
Solicitation number
W9123620B2011
Issued by

About this file

This document contains a reflected ceiling plan amendment for the renovation of Building 32, Bays F-G at the Defense Supply Center Richmond in Virginia to relocate an existing fitness center, as well as a pre-solicitation notice for the construction project.

The reflected ceiling plan amendment provides details on the proposed ceiling finishes, fixtures, and equipment for the renovated fitness center spaces, including offices, a wellness center, racquetball courts, gymnasium, locker rooms, and support areas. The pre-solicitation notice indicates that the construction project is a 100% small business set-aside to be awarded via sealed bid as a firm-fixed-price contract between $5-10 million. The completion period is 450 days after notice to proceed. The solicitation will be issued on April 9, 2020 with proposals due on May 7, 2020. The work is being conducted by the U.S. Army Corps of Engineers Norfolk District on behalf of the Department of the Army.

View the file

Other files

File Type Posted
B.01.02_Abstract of Offers Page 2 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Revised Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Abstract of Offers Page 2 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
B.01.02_Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
118ECE908 AMDT 004 DRAWINGS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 21 13 dated 082017 updated 05142020 10 pages.pdf PDF
20-B-2011 Amend 0004.pdf PDF
118ECE908 AMDT 004 SPECIFICATIONS dated 05142020 1556 pages.pdf PDF
118ECE908 AMDT 004 A 401 ENLARGED LOCKER ROOM RESTROOM PLANS AND TYPICAL ELEVATIONS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 51 13 dated 05201 updated 05142020 1 6 pages.pdf PDF
Typed Site Visit Sign In Sheet for DLA Fitness Center 04222020.pdf PDF
W91236-20-B-2011 Amendment 3.pdf PDF
118ECE908 AMDT 002 11 66 23.pdf PDF
W9123620B0011 Amendment 2.pdf PDF
118ECE908 AMDT 002 DRAWINGS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111A REFLECTED CEILING PLAN AREA A.pdf PDF
118ECE908 AMDT 002 08 41 13.pdf PDF
118ECE908 AMDT 002 A111C REFLECTED CEILING PLAN AREA C.pdf PDF
118ECE908 AMDT 002 SPECIFICATIONS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111D REFLECTED CEILING PLAN AREA D.pdf PDF
118ECE908 AMDT 002 FF AND E BINDER 05MAY2020.pdf PDF
118ECE908 AMDT 002 I 101B FINISH PLAN AREA B.pdf PDF
118ECE908 AMDT 002 A002 PARTITION TYPES.pdf PDF
118ECE908 AMDT 002 A101B FLOOR PLAN AREA B.pdf PDF
118ECE908 AMDT 002 10 23 10.pdf PDF
118ECE908 AMDT 002 A101C FLOOR PLAN AREA C.pdf PDF
S-302 SECTIONS AND DETAILS -II.pdf PDF
S-201 FRAMING ELEVATIONS AND DETAILS.pdf PDF
S-301 SECTIONS AND DETAILS -I.pdf PDF
S-501 TYPICAL STRUCTURAL DETAILS -I.pdf PDF
S-001 GENERAL STRUCTURAL NOTES.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
S-121C TRUSS BOTTOM CHORD PLAN -AREA C.pdf PDF
S-101 OVERALL FOUNDATION PLAN.pdf PDF
A.01.13_118ECE908 AMDT 002 33 40 00 dated 022010 11 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 GC002 dated 04292020 1 page.pdf PDF
A.01.13_118ECE908 AMDT 002 01 11 00.00 50 dated 022013 14 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 CG 100 dated 04292020 1 page.pdf PDF
20-B-2011 Amendment 1.pdf PDF
A.01.13_118ECE908 AMDT 002 CU 101 dated 04292020 1 page.pdf PDF
A.01.13_118ECE908 AMDT 002 CG 102 dated 04292020 1 page.pdf PDF
G.01.47_PreBid Sign In Sheet for Fitness Center 04222020.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
I101C FLOOR FINISH PLAN -AREA C.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
Show 40 more

Latest 50 of 76 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

C

C

C

C

ET ET

C

C

C

C

C

C

C

C

C

C

C

C

1 2 3 4 5 6 7

H

I

J

EXISTING

TELECOM

F117

JANITOR

F118

LAUNDRY

F119

BREEZEWAY

F100

SAUNA

F116B

WOMEN LOCKER

F116C

MEN LOCKER

F115C

STEAM

F116D

MECH.

F116E

MECH.

F115E

STEAM

F115D

SAUNA

F115B

CORRIDOR

F101A

CORRIDOR

F101B

8' - 0"

8' - 0" 8' - 0"

8' - 0"

10' - 0"

10' - 0"

106 106

WOMEN

RESTROOM

F116AMEN RESTROOM

F115A

MEN SHOWERS

F115F

WOMEN SHOWERS

F116F

10' - 0" 10' - 0"

10' - 0"

10' - 0"

REFLECTED CEILING LEGEND

EXIT LIGHT - CEILING

2' x 2' SUSPENDED

ACOUSTIC CEILING TILES

GYPSUM BOARD CEILING

2 X 4 LIGHT FIXTURE

SUSPENDED LIGHT FIXTURE

RETURN AIR GRILLE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

CEILING HEIGHT TAG

SD

S

SMOKE DETECTOR

SPEAKER

8'-0"

2' x 2' SUSPENDED

CEILING CLOUD W/MESH

STROBE

WOOD CEILING

4' X 8' CEMENTITIOUS

WOOD FIBER ACOUSTICAL

CEILING PANELS

1 X 4 LIGHT FIXTURE

RECESSED LIGHT FIXTURE

RECESSED DOWN LIGHT

PORCELAIN TILE CEILING

CEILING FAN

4X8 T&G CEILING PANEL

A. CENTER CEILING GRID IN ROOM UNLESS SHOWN

OTHERWISE ON REFLECTED CEILING PLAN.

B. CENTER FIXTURES, MECHANICAL DIFFUSERS,

MECHANICAL GRILLES AND SPRINKLER HEADS IN

SUSPENDED ACOUSTICAL CEILING TILE SYSTEM

PANELS.

C. ALL CEILING MOUNTED ITEMS ARE SHOWN FOR

COORDINATION PURPOSES ONLY.

D. SEE ELECTRICAL DRAWINGS FOR LIGHT FIXTURE

AND SPECIAL SYSTEM TYPES.

E. SEE MECHANICAL DRAWINGS FOR DIFFUSER AND

GRILLE TYPES.

F. SEE FIRE PROTECTION FOR SPRINKLER TYPES.

SEE TELECOMMUNICATION AND FIRE PROTECTION

SYSTEMS FOR ADDITIONAL INFORMATION OF

CEILING MOUNTED DEVICES.

G. ALL RCP DIMENSIONS ARE CLEAR FINISHED

DIMENSIONS, UNLESS OTHERWISE NOTED.

H. REFER TO FINISH SCHEDULE FOR CEILING TYPES

AND HEIGHTS NOT INDICATED ON THE REFLECTED

CEILING PLANS.

I. ALL GYPSUM BOARD CEILING WITHIN 4'-0" OF

PERIMETER SHALL BE MOISTURE RESISTANT.

J. SMOKE AND HEAT DETECTORS TO BE GREATER

THAN 3'-0" FROM MECHANICAL DIFFUSERS.

RCP GENERAL NOTES:

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O L K

D

IS

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

E R

W -1

-R

-0

W -1

-R

-0

A-111B

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

B K

.F E

L T

O N

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

SCALE : 1/8" = 1'-0"A1 REFLECTED CEILING PLAN - AREA B

BAY GBAY F

KEY PLAN

B

REFERENCE KEYNOTES:

106 GYPSUM BOARD BULKHEAD, REFER TO CEILING

DETAILS

108 EXPOSED STRUCTURE ABOVE. PAINT ALL EXPOSED

STRUCTURE AND PIPES.

133 2'-0"X 2'-0" ACCESS PANEL. SEE DETAIL A1/A-511