A.01.13_118ECE908 AMDT 002 CG 102 dated 04292020 1 page.pdf

PDF 562 KB Posted

Attached to
DLA Fitness Center Renovation
Solicitation number
W9123620B2011
Issued by

About this file

This pre-solicitation notice is for a firm-fixed-price construction contract between $5-10 million to renovate the Defense Supply Center Richmond Fitness Center located in Richmond, Virginia. The U.S. Army Corps of Engineers Norfolk District intends to award a single contract with a performance period of 450 days after notice to proceed. The renovation work includes offices, wellness facilities, racquetball courts, a gymnasium, locker rooms, and storage areas. The solicitation will be issued on April 9, 2020 with proposals due on May 7, 2020. The solicitation and any amendments will be available through the SAM website. This is a 100% small business set-aside using sealed bids and definitive responsibility criteria.

View the file

Other files

File Type Posted
B.01.02_Abstract of Offers Page 2 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Revised Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 Revised (CONST) W9123620B2011 Fitness Center Bid Opening 07012020.pdf PDF
B.01.02_Abstract of Offers Page 2 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
B.01.02_Abstract of Offers Page 1 (CONST) W9123620B2011 Fitness Center Bid Opening 06012020.pdf PDF
B.01.02_Abstract of Offers Page 3 (CONST) W9123620B2011 Fitness Center Bid Opening 05282020.pdf PDF
118ECE908 AMDT 004 DRAWINGS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 21 13 dated 082017 updated 05142020 10 pages.pdf PDF
20-B-2011 Amend 0004.pdf PDF
118ECE908 AMDT 004 SPECIFICATIONS dated 05142020 1556 pages.pdf PDF
118ECE908 AMDT 004 A 401 ENLARGED LOCKER ROOM RESTROOM PLANS AND TYPICAL ELEVATIONS dated 05142020 1 page.pdf PDF
118ECE908 AMDT 004 10 51 13 dated 05201 updated 05142020 1 6 pages.pdf PDF
Typed Site Visit Sign In Sheet for DLA Fitness Center 04222020.pdf PDF
W91236-20-B-2011 Amendment 3.pdf PDF
118ECE908 AMDT 002 11 66 23.pdf PDF
W9123620B0011 Amendment 2.pdf PDF
118ECE908 AMDT 002 DRAWINGS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111A REFLECTED CEILING PLAN AREA A.pdf PDF
118ECE908 AMDT 002 A111B REFLECTED CEILING PLAN AREA B.pdf PDF
118ECE908 AMDT 002 08 41 13.pdf PDF
118ECE908 AMDT 002 A111C REFLECTED CEILING PLAN AREA C.pdf PDF
118ECE908 AMDT 002 SPECIFICATIONS 05MAY2020.pdf PDF
118ECE908 AMDT 002 A111D REFLECTED CEILING PLAN AREA D.pdf PDF
118ECE908 AMDT 002 FF AND E BINDER 05MAY2020.pdf PDF
118ECE908 AMDT 002 I 101B FINISH PLAN AREA B.pdf PDF
118ECE908 AMDT 002 A002 PARTITION TYPES.pdf PDF
118ECE908 AMDT 002 A101B FLOOR PLAN AREA B.pdf PDF
118ECE908 AMDT 002 10 23 10.pdf PDF
118ECE908 AMDT 002 A101C FLOOR PLAN AREA C.pdf PDF
S-302 SECTIONS AND DETAILS -II.pdf PDF
S-201 FRAMING ELEVATIONS AND DETAILS.pdf PDF
S-301 SECTIONS AND DETAILS -I.pdf PDF
S-501 TYPICAL STRUCTURAL DETAILS -I.pdf PDF
S-001 GENERAL STRUCTURAL NOTES.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
S-121C TRUSS BOTTOM CHORD PLAN -AREA C.pdf PDF
S-101 OVERALL FOUNDATION PLAN.pdf PDF
A.01.13_118ECE908 AMDT 002 33 40 00 dated 022010 11 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 GC002 dated 04292020 1 page.pdf PDF
A.01.13_118ECE908 AMDT 002 01 11 00.00 50 dated 022013 14 pages.pdf PDF
A.01.13_118ECE908 AMDT 002 CG 100 dated 04292020 1 page.pdf PDF
20-B-2011 Amendment 1.pdf PDF
A.01.13_118ECE908 AMDT 002 CU 101 dated 04292020 1 page.pdf PDF
G.01.47_PreBid Sign In Sheet for Fitness Center 04222020.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
I101C FLOOR FINISH PLAN -AREA C.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
Show 40 more

Latest 50 of 76 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

K

S

T E

D M

A N

S

T

I N

I U

S

K

S

T E

D M

A N

K

S

T E

D M

A N

US Army Corps of Engineers ®

SHEET

ID

U S

A

R M

Y

C

O R

P

O

F

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

F I L E

N

A M

E

I S

S U

E

D

A T

E

C O

N T

R A

C T

S O

L I C

I T

A T

I O

N

N

O

F I

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

K

D

I S

T R

I C

T

N O

R F

O L K

V

I R

G I N

I A

READY TO ADVERTISE

D E

F E

N S

E

S

U P

P

Y

N

T E

R

R

I C

H M

O N

D

D

S C

R

V

I R

G I N

I A

C O

N V

E R

T

B

B

A Y

S

F

G

F

I T

N E

N

T E

R

P R

O J E

T

E

C E

N O

V E

M B

R

W R

W R

M A

R K

D E

S C

R I P

T I O

N D

A T

E

CG102

E R

O S

I O

N

C

O N

T R

D

T

A I L

S

NOT TO SCALE

DROP INLET PROTECTION (VA-3.07)

CONSTRUCTION ENTRANCE

NOT TO SCALE

SILT FENCE (VA 3.05)

NOT TO SCALE

PAINT

WASHOUT

0.5" LAG SCREWS

WASHOUT SIGN DETAIL

OR EQUIVALENT

CONCRETE

WASHOUT

0.5" LAG SCREWS

NOT TO SCALE

PAINT AND CONCRETE WASHOUT DETAIL

PLYWOOD 48" X 24" PAINTED

WHITE

BLACK LETTERS 3" HEIGHT

WOOD POST 3" X 3" X 8'

PLYWOOD 48" X 24"

PAINTED WHITE

BLACK LETTERS 3" HEIGHT

WOOD POST 3" X 3" X 8'

D7

D3

D1

A3

PLYWOOD OFFSET BY 2' FOR STAGGERED BUMPS

A A

A A

2"X4"X4'2"X6"X4'

3/4" PLYWOOD 4'X8'

NOTE:

CONTRACTOR TO PROVIDE CONSTRUCTION ENTRANCE(S) AS NECESSARY. CONSTRUCT ADDITIONAL BUMP

BOARDS AS NECESSARY IF WHEEL DEBRIS IS NOT KNOCKED OFF TIRES WITH ONE SET. SWEEP DEBRIS

COLLECTED BY BUMP BOARDS AS NECESSARY.

A M

E N

D M

E N

T

AutoCAD SHX Text

STAKE (TYP)

AutoCAD SHX Text

10 MIL PLASTIC LINING

AutoCAD SHX Text

TWO-STACKED 2X12 ROUGH WOOD FRAME

AutoCAD SHX Text

WOOD FRAME SECURELY FASTENED AROUND ENTIRE PERMIETER WITH TWO STAKES

AutoCAD SHX Text

10 MIL PLASTIC LINING

AutoCAD SHX Text

10 MIL PLASTIC LINING

AutoCAD SHX Text

SANDBAG

AutoCAD SHX Text

LATH & FLAGGING ON ALL SIDES

AutoCAD SHX Text

BERM

AutoCAD SHX Text

10 MIL PLASTIC LINING

AutoCAD SHX Text

SANDBAG

AutoCAD SHX Text

BERM

AutoCAD SHX Text

TYPE "BELOW GRADE"

AutoCAD SHX Text

TYPE "ABOVE GRADE"

AutoCAD SHX Text

PLAN NOT TO SCALE

AutoCAD SHX Text

SECTION B-B NOT TO SCALE

AutoCAD SHX Text

SECTION A-A NOT TO SCALE

AutoCAD SHX Text

PLAN NOT TO SCALE

AutoCAD SHX Text NOTES 1. ACTUAL LAYOUT DETERMINED IN FIELD. 2. THE CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30 FT. OF TEMPORARY CONCRETE WASHOUT FACILITY. 3. SEE SPECIFICATION 01 57 19

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text

File details come from the government source that posted it. Updated .