This document package includes architectural drawings and plans for the Defense Logistics Agency Aviation Operations Center, Phase II project. Key details include the following:
The drawings cover first through fifth floor plans, reflected ceiling plans, elevations, sections, and details for the construction of a new five-story office building totaling approximately 237,000 square feet. Relevant construction areas include the main entry lobby, stairs, elevators, restrooms, and an enclosed loading dock. Additional areas of note are a metrology lab and mylar room. The solicitation is for construction services to be completed according to the specifications laid out in the architectural package. The federal agency overseeing the project is the Department of the Army Corps of Engineers Engineering District Norfolk.
View the file
Other files
Show 40 more
Latest 50 of 127 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A N
N
L O
C
E
Y B
Y D
Y A
Y
Y
Y
Y C
A
Y
Y
D
B C
A -2
D
A -2
D
V E
S T
IB
U
L E
1A
1B
1C
1D
O F
F
IC
E C
U B
IC
L E
S
L O
B B
Y
A -5
A
A -4
A
A -5
A
A -5
A
A -5
C
C W
W
W
S T
O R
W
W
W
W
W
W
A
A -3
A
A -3
A
A -3
A
A -3
S
IM
A -5
G
S
IM
A -5
G
S
IM
A -5
G
S
IM
A -5
G
S
IM
A -5
D
A -5
D
A
A
A
A
A
A6
A 4 A
A
A
A -5
D
A -5
D
A -5
F
A -5
F
S
IM
X C
.8
'-6
1'
-5
6' -7
9' -4
3' -4
C
B
'-2
'-4
/2
'-9
'-5
'-5
3' -0
/2
'-4
3' -1
3/
2' -1
0"
'-4
3'
-1 0"
2' -9
'-4
3' -1
0" 1'
-1 0"
5'-4 1/4" 16'-8" 7'-0 1/2" 16'-8"
6' -8
'-8
3' -4
8' -1
3/
4" 1' -0
'-1
1/
2"
1' -0
8' -1
1"
2' -2
A -5
G
S
IM
F E
C
W
W
2'-0"
6'-8" 1'-4"
2'-0"
17'-8"
2'-0"
1'-4" 6'-8"
2'-0"
1'-4"
C W
8' -0
9'-4 13/16"
A -2
E
A -2
E
A -2
B
W
1' -5
6' -7
9' -4
3' -4
1/ 2"
84" TV 84" TV
G E
N E
R A
L N
O T
E S
A
S E
E S
H E
E T
A -0
F O
R G
E N
E R
A L
N O
T E
S
B
S E
E S
H E
E T
A -1
F O
R P
A R
T
IT
IO
N
S C
H E
D U
L E
C
S E
E S
H E
E T
S A
-6
T
H R
O U
G H
A -6
F O
R A
L L
W
IN
D O
W C
U R
T A
IN
W
A L
L A
N D
T
O R
E F
R O
N T
E L
E V
A T
IO
N
S
D
S E
E S
H E
E T
S A
-7
T
H R
O U
G H
A -7
F O
R F
IN
IS
H S
C H
E D
U L
E S
D A V
ID
P
IS
B E L L
AINI
G
RI
V
F O
H T
L A
E W
NOMMOC
N o
A R C H T I E C T
U S
A rm y C o rp s o f
E n g in e e rs
H
E E
T O
F
S H
E E
T I
D
US ARMY CORPS OF ENGINEERS
DRAWN BY:
DESIGNED BY:
SUBMITTED BY:
SIZE:
CHECKED BY:
ANSI D
ISSUE DATE:
SOLICITATION NO.:
G
F E D C B A
DATE MARKDESCRIPTION
C Y
P R
E S
S A
V E
N U
E
V
IR
G
IN
IA
B
E A
C H
V
A
(7
CONTRACT NO.:
W91236-17-D-002
J A
N U
A R
Y
A -1
8FIRST FLOOR PLAN -AREA C1
DEFENSE SUPPLY CENTER RICHMOND (DSCR), RICHMOND, VIRGINIA
NORFOLK DISTRICT
803 FRONT ST. NORFOLK, VA. 23510
WALLER TODD & SADLER,
A WOOLPERT COMPANY
1909 CYPRESS AVENUE
VIRGINIA BEACH, VA 23451
DSR
MOH
DSR
DPI
10 JANUARY 2020
DLA OPERATIONS CENTER (PH-2)
DEFENSE LOGISTICS AGENCY -AVIATION
DSCR1901
8' 4'
/8
"G
R A
P H
IC
S
C A
LE
K E
Y P
L A
N N
O T
T O
S C
A L
E
A
B
C
D
E
F
G
/8
A -2
B
F
IR
S T
F L
O O
R P
L A
N
A R
E A
C
S H
E E
T K
E Y
N O
TE
S
F
IR
E
E X
T
IN
G U
IS
H
E R
C A
B
IN
E T
F
U L
L Y
R E
C E
S S
E D
R
A
IN
L E
A D
E R
T H
R U
W A
L L
W
IT
H S
P L
A S
H B
L O
C K
L
O C
A T
E L
A M
B S
T O
N G
U E
A .F
.F
W
A L
L H
Y D
R A
N T
S
E E
P L
U M
B
IN
G D
R A
W
IN
G S
1AMENDMENT NO. 106-22-20
| Sheets |
| A-101 - OVERALL FIRST FLOOR PLAN |
| A-102 - OVERALL SECOND FLOOR PLAN |
| A-103 - OVERALL THIRD FLOOR PLAN |
| A-104 - OVERALL FOURTH FLOOR PLAN |
| A-105 - OVERALL FIFTH FLOOR PLAN |
| A-106 - FIRST FLOOR PLAN - AREA A1 |
| A-107 - FIRST FLOOR PLAN - AREA B1 |
| A-108 - FIRST FLOOR PLAN - AREA C1 |
| A-109 - FIRST FLOOR PLAN - AREA D1 |
| A-110 - FIRST FLOOR PLAN - AREA E1 |
| A-111 - FIRST FLOOR PLAN - AREA F1 |
| A-112 - FIRST FLOOR PLAN - AREA G1 |
| A-113 - SECOND FLOOR PLAN - AREA A2 |
| A-114 - SECOND FLOOR PLAN - AREA D2 |
| A-115 - SECOND FLOOR PLAN - AREA F2 |
| A-116 - SECOND FLOOR PLAN - AREA G2 |
| A-117 - THIRD FLOOR PLAN - AREA A3 |
| A-118 - THIRD FLOOR PLAN - AREA D3 |
| A-119 - FOURTH FLOOR PLAN - AREA A4 |
| A-120 - FOURTH FLOOR PLAN - AREA D4 |
| A-121 - FIFTH FLOOR PLAN - AREA A5 |
| A-122 - FIFTH FLOOR PLAN - AREA D5 |
| A-123 - FIRST FLOOR OVERALL REFLECTED CEILING PLAN |
| A-124 - SECOND FLOOR OVERALL REFLECTED CEILING PLAN |
| A-125 - THIRD, FOURTH AND FIFTH FLOOR OVERALL REFLECTED CEILING PLANS |
| A-126 - FIRST FLOOR REFLECTED CEILING PLAN - AREA A1 |
| A-127 - FIRST FLOOR REFLECTED CEILING PLAN - AREA B1 |
| A-128 - FIRST FLOOR REFLECTED CEILING PLAN - AREA C1 |
| A-129 - FIRST FLOOR REFLECTED CEILING PLAN - AREA D1 |
| A-130 - FIRST FLOOR REFLECTED CEILING PLAN - AREA E1 |
| A-131 - FIRST FLOOR REFLECTED CEILING PLAN - AREA F1 |
| A-132 - FIRST FLOOR REFLECTED CEILING PLAN - AREA G1 |
| A-133 - SECOND FLOOR REFLECTED CEILING PLAN - AREA A2 |
| A-134 - SECOND FLOOR REFLECTED CEILING PLAN - AREA D2 |
| A-135 - SECOND FLOOR REFLECTED CEILING PLAN - AREA F2 |
| A-136 - SECOND FLOOR RELFECTED CEILING PLAN - AREA G2 |
| A-137 - THIRD FLOOR REFLECTED CEILING PLAN - AREA A3 |
| A-138 - THIRD FLOOR REFLECTED CEILING PLAN - AREA D3 |
| A-139 - FOURTH FLOOR REFLECTED CEILING PLAN - AREA A4 |
| A-140 - FOURTH FLOOR REFLECTED CEILING PLAN - AREA D4 |
| A-141 - FIFTH FLOOR REFLECTED CEILING PLAN - AREA A5 |
| A-142 - FIFTH FLOOR REFLECTED CEILING PLAN - AREA D5 |
| A-143 - OVERALL ROOF PLAN |
| A-144 - PARTIAL LOW LEVEL ROOF PLAN |
| A-145 - PARTIAL LOW LEVEL ROOF PLAN |
| A-146 - HIGH LEVEL ROOF PLAN |
| A-201 - NORTH AND SOUTH ELEVATIONS |
| A-202 - EAST AND WEST ELEVATIONS |
| A-203 - ENLARGED ELEVATIONS |
| A-204 - ENLARGED ELEVATIONS |
| A-205 - ENLARGED ELEVATIONS |
| A-206 - ENLARGED ELEVATIONS |
| A-207 - ENLARGED ELEVATIONS |
| A-208 - ENLARGED ELEVATIONS |
| A-209 - ENLARGED ELEVATIONS |
| A-301 - BUILDING CROSS SECTION |
| A-302 - BUILDING CROSS SECTION |
| A-303 - BUILDING CROSS SECTION |
| A-304 - BUILDING LONGITUDINAL SECTION |
| A-305 - BUILDING LONGITUDINAL SECTION |
| A-306 - BUILDING LONGITUDINAL SECTION |
| A-307 - WALL SECTIONS |
| A-308 - WALL SECTIONS |
| A-309 - WALL SECTIONS |
| A-310 - WALL SECTIONS |
| A-311 - WALL SECTIONS |
| A-312 - WALL SECTIONS |
| A-313 - WALL SECTIONS |
| A-314 - WALL SECTIONS |
| A-315 - WALL SECTIONS |
| A-316 - WALL SECTIONS |
| A-317 - WALL SECTIONS |
| A-318 - WALL SECTIONS |
| A-319 - WALL SECTIONS |
| A-401 - ENLARGED MAIN ENTRY PLAN, ELEVATIONS AND DETAILS |
| A-402 - ENLARGED STAIR PLANS - AREA A |
| A-403 - ENLARGED STAIR PLANS - AREA D |
| A-404 - ENLARGED STAIR PLANS - AREA G |
| A-405 - STAIR SECTIONS - AREA A |
| A-406 - STAIR SECTIONS - AREA D |
| A-407 - STAIR SECTIONS - AREA G |
| A-408 - STAIR DETAILS |
| A-409 - STAIR DETAILS |
| A-410 - ENLARGED ELEVATOR PLANS, SECTIONS AND DETAILS - AREA D |
| A-411 - ENLARGED ELEVATOR PLANS, SECTIONS AND DETAILS - AREA F |
| A-412 - ENLARGED PLAZA PLANS AND DETAILS |
| A-413 - EXTERIOR RAMP PLANS, STAIR PLAN AND DETAILS |
| A-414 - ENLARGED LOADING DOCK PLAN AND DETAILS |
| A-415 - ENLARGED MAIN ENTRY PLAN, ELEVATIONS AND DETAILS |
| A-416 - ENLARGED TOILET PLANS AND MOUNTING SCHEDULE |
| A-417 - ENLARGED TOILET PLANS AND MOUNTING SCHEDULE |
| A-418 - ENLARGED COFFEE KIOSK AND SUNDRIES PLANS, ELEVATIONS AND DETAILS |
| A-419 - CASEWORK ELEVATIONS AND DETAILS |
| A-420 - ENLARGED TOILET PLANS |
| A-421 - ENLARGED METROLOGY LAB AND MYLAR ROOM PLAN |
| A-422 - EXTERIOR SIGNAGE PLAN, ELEVATIONS, SECTIONS AND DETAILS |
| A-423 - DUMPSTER PLAN, ELEVATION, SECTION AND DETAIL |
| A-501 - MISCELLANEOUS ROOF DETAILS |
| A-502 - ROOF DETAILS |
| A-503 - ROOF DETAILS |
| A-504 - ROOF DETAILS |
| A-505 - CANOPY DETAILS |
| A-506 - COLUMN DETAILS |
| A-507 - COLUMN DETAILS |
| A-508 - COLUMN DETAILS |
| A-509 - COLUMN DETAILS |
| A-510 - COLUMN DETAILS |
| A-511 - COLUMN DETAILS |
| A-512 - COLUMN DETAILS |
| A-513 - COLUMN DETAILS |
| A-514 - COLUMN DETAILS |
| A-515 - COLUMN DETAILS |
| A-516 - COLUMN DETAILS |
| A-517 - COLUMN DETAILS |
| A-518 - COLUMN DETAILS |
| A-519 - COLUMN DETAILS |
| A-520 - COLUMN DETAILS |
| A-521 - COLUMN DETAILS |
| A-522 - COLUMN DETAILS |
| A-523 - CEILING DETAILS |
| A-524 - CEILING DETAILS |
| A-525 - CEILING DETAILS |
| A-526 - MISCELLANEOUS DETAILS |
| A-527 - MISCELLANEOUS DETAILS |
| A-601 - DOOR SCHEDULE |
| A-602 - DOOR SCHEDULE |
| A-603 - DOOR SCHEDULE AND DETAILS |
| A-604 - DOOR DETAILS |
| A-605 - WINDOW AND CURTAIN WALL ELEVATIONS |
| A-606 - CURTAINWALL ELEVATIONS |
| A-607 - CURTAINWALL ELEVATIONS |
| A-608 - CURTAIN WALL ELEVATIONS |
| A-609 - CURTAIN WALL ELEVATIONS |
| A-610 - STOREFRONT ELEVATIONS |
| A-611 - WINDOW DETAILS |
| A-612 - CURTAIN WALL DETAILS |
| A-613 - CURTAIN WALL DETAILS |
| A-614 - CURTAIN WALL DETAILS |
| A-615 - CURTAIN WALL DETAILS |
| A-616 - CURTAIN WALL DETAILS |
| A-617 - CURTAIN WALL DETAILS |
| A-618 - CURTAIN WALL DETAILS |
| A-619 - CURTAIN WALL DETAILS |
File details come from the government source that posted it. Updated .