Revised_Plumbing_Sheets_-_Inquiry__6793897.pdf
PDF 2 MB Posted
- Solicitation number
- W911KB-17-R-0010
About this file
Revised Plumbing Drawings: P-900121B, P-900122B, P-900123B, P-900124B, P-900402B, P-900606B, P-900607B, P-900701B
View the file
Other files
Show 40 more
Latest 50 of 128 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
C
D
E
E.2
F
G
H
1 2 3 4 5 6 7
MECH ROOM 1
PIPE ENTRY 3
SSUPS ROOM
IWH-90012002
ES-90012001
3/4"CA
1-1/2"CW
3/4"CA HOSE
REEL DN.
3/4"CA HOSE
REEL DN.
1-1/2"TW
MV-90012001
ELEC ROOM 1
LES LINK
S.O.V.
S.O.V.
BOILER ROOM
1-1/2"CW
CORR
BATTERY ROOM
1-1/2"CA
1-1/2"CA
1"ICW TO SERVE
BOILER SYSTEM
S.O.V.
S.O.V.
SEE SHEET P900123B
S E
E S
H E
E T
P B
SEE SHEET P900124B
S.O.V.
S.O.V.
S.O.V.
3/4"ICW
3/4"ICW
FOR WELL WATER PUMP SUPPLY
FOR CONT. REFER TO
MP900601B (TYP OF 3)
3/4"CA
3/4" ICW TO
CRAC-90041003A,
SEE MECH DWGS.
ES-90012002
A B
C D
E
LES
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/1
/2
:3 :1
P
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
P
L U
M B c h e ls e a .d e c a s tr o .r v t
RTA P-900121B
P L U
M B
IN
G
D O
M E
S T
I C W
A T
E R
A N
D C
O M
P R
E S
S E
D A
IR
F
L O
O R
P L A
N A
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P .W
U
K .M
A Y
O R
K .M
A Y
O R
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
:1
CL
R_
LR
DR
_M
CF
_P
LU
M B_
A F
-1
- 3
-0
1/8" = 1'-0"P-900121B
1 PLUMBING DOMESTIC WATER AND COMPRESSED AIR FLOOR PLAN A
GENERAL NOTES:
A. FOR GENERAL PLUMBING LEGEND AND
SYMBOLS, SEE SHEET P-900001B.
B. FOR CONTINUATION OF UTILITIES, SEE
CIVIL ENGINEER'S DRAWINGS.
C. SEE MECHANICAL DRAWINGS FOR
EXACT LOCATION AND MORE INFORMATION
FOR MECHANICAL UNITS.
D. REFER TO SHEET A-900008B FOR HEMP
SHIELD.
E. FACULTY COMPRESSED AIR SYSTEM
DESIGN IS TO PROVIDE OIL FACE SUPPLY
LOOP. OIL LUBRICATOR IF REQUIRED AT ANY
TOOL(S) AND EQUIPMENT SHALL BE
PROVIDED BY USER.
PLAN NORTH
SCALE:
0 8' 16'
1/8" = 1' - 0"
8' 16'
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUTS/NOTES ARE INCHES UNLESS OTHERWISE NOTED
KEYNOTES:
1/2"CA W/ S.O.V. INSIDE THE HEMP
TO HEMP DOOR CONTROLLER.
IWH-90012002 SHALL BE FREE STANDING
INSTALLATION AND MOUNTED ON THE FLOOR.
SPILL WATER HEATER DISCHARGE TO
NEAREST FLOOR SINK WITH MINIMUM 2"
AIR GAP.
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.1
B T
N
A
B
C
D
E
E.2
F
G
H
7 8 9 10 11 12 13 14
MECH ROOM 1
FUTURE LPP
CONN
PIPE ENTRY 2
RADAR
PROCESSING
ROOM
MECH ROOM 3
1-1/2"CW
1"CA, 2"CW & 1"ICW W/
S.O.V. CAPPED FOR
FUTURE LPP.
1-1/2"CA
1"CA
ES-90012002
1/2"CA
1"ICW
1"ICW
1-1/2"CW
2-1/2"CW
3/4"CA HOSE
REEL DN.
3/4"CA HOSE
REEL DN.
S-90012002
1/2"CW
3/4"HW
ELEC ROOM 1
CLEAN AGENT
DOCK VESTIBULE
MAINTENANCE
SHOP
FOM OFFICE
MAINT LIBRARY
PM/UO OFFICE
PARTS STORAGE
COMM CMC
CORR
MECH ROOM 2
SHUT-OFF VALVE
(TYPICAL)
HB-90012001
3/4"CW
3/4"ICW
3/4" ICW TO CRAC-90041001A,
CRAC-90041001B, &
CRAC-90041001C
SEE MECH DWGS.
S.O.V.
S.O.V.
(TYP.)
S.O.V. 1"ICW
2"CW
1"ICW
CORR
LOADING DOCK
BATTERY ROOM
CORR
CORR
3/4"HW
3/4"HWR
S.O.V.
3/4"ICW7
1"ICW
SEE SHEET P900124B
SEE SHEET P900121B
S.O.V. S.O.V. S.O.V.
FOR WELL WATER
PUMP FOR SUPPLY.
FOR CONT. REFER TO
MP900601B (TYP OF 3)
3/4"ICW 3/4"ICW
3/4" CA
C P
-B
C P
-C
3/4" ICW TO
CRAC-90041003A,
SEE MECH DWGS.
3/4"
ES-90012002
P.O.C. 3/4" ICW W/ S.O.V. TO MECH EQUIPMENT.
SEE MECHANICAL DWGS
FOR CONTINUATION
MDCR
HB-90012002
5P900212
3/4" ICW
3/4"HW
3/4"HWR
3/4"HW
3/4"CW
A B
C D
E
LES
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/1
/2
:3 :2
P
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
P
L U
M B c h e ls e a .d e c a s tr o .r v t
RTA P-900122B
P L U
M B
IN
G
D O
M E
S T
I C W
A T
E R
A N
D C
O M
P R
E S
S E
D A
IR
F
L O
O R
P L A
N B
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P .W
U
K .M
A Y
O R
K .M
A Y
O R
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
:1
CL
R_
LR
DR
_M
CF
_P
LU
M B_
A F
-1
- 3
-0
1/8" = 1'-0"P-900122B
1 PLUMBING DOMESTIC WATER AND COMPRESSED AIR FLOOR PLAN B
GENERAL NOTES:
A. FOR GENERAL PLUMBING LEGEND AND
SYMBOLS, SEE SHEET P-900001B.
B. FOR CONTINUATION OF UTILITIES, SEE
CIVIL ENGINEER'S DRAWINGS.
C. SEE MECHANICAL DRAWINGS FOR
EXACT LOCATION AND MORE INFORMATION
FOR MECHANICAL UNITS.
D. REFER TO SHEET A-900008B FOR HEMP
SHIELD.
E. FACULTY COMPRESSED AIR SYSTEM
DESIGN IS TO PROVIDE OIL FACE SUPPLY
LOOP. OIL LUBRICATOR IF REQUIRED AT ANY
TOOL(S) AND EQUIPMENT SHALL BE PROVIDED
BY USER.
KEYNOTES:
1/2"CA W/ S.O.V. INSIDE THE HEMP
TO HEMP DOOR CONTROLLER.
BELOW FLOOR TILE IN
RECESSED FLOOR SPACE.
PLAN NORTH
SCALE:
0 8' 16'
1/8" = 1' - 0"
8' 16'
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUTS/NOTES ARE INCHES UNLESS OTHERWISE NOTED
OIL FREE COMPRESSED
AIR. OIL LUBRICATOR IF
REQUIRED AT TOOL(S)
SHALL BE PROVIDED BY
USER.
PIPE FOR FUTURE
CONNECTION PROVIDE 4-
WAY SEISMIC BRACE NEAR
END OF PIPE.
HEMP PENETRATION.5
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.1
B T
N
H
I
J
K
L
M
N
O
1 2 3 4 5 6 7
ANTENNA
COOLING SYS
MAIN ELEC ROOM
FIRE PUMP ROOM
AC-90011001A
AC-90011001B
AR-90011001
WEATHER VEST
PIPE ENTRY 1A
LES LINK
126 3/4" ICW TO
CRAC-90041003A,
SEE MECH DWGS.
S.O.V.
3/4"ICW DN W/ S.O.V. TO
CRAC-90041004A,
CRAC-90041004B,
SEE MECH DWGS.
CORR
PIPE ENTRY 1B
PARTS STORAGE
RADAR
MAINTENANCE
EMI TEST
ENCLOSURE
CORR
S.O.V.
3/4"CA 1-1/2"CA
1-1/2"CA
1-1/2"CA
1-1/2"CA W/ S.O.V.
FOR RADAR PRIME
FUTURE CONNECTION
S.O.V.
3/4"ICW
SEE SHEET P900124B
SEE SHEET P900121B
3/4"CA
1-1/2"CA
1-1/2"ICW TO LES
1"CW TO LES
CP1-B
RADAR
3/4" ICW TO
CRAC-90041003A,
SEE MECH DWGS.
1-1/2"ICW TO LES
1"CW TO LES
1"ICW
3"CW
C P
-B
R A
D A
R
A B
C D
E
LES
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/1
/2
:3 :2
P
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
P
L U
M B c h e ls e a .d e c a s tr o .r v t
RTA P-900123B
P L U
M B
IN
G
D O
M E
S T
I C W
A T
E R
A N
D C
O M
P R
E S
S E
D A
IR
F
L O
O R
P L A
N C
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P .W
U
K .M
A Y
O R
K .M
A Y
O R
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
:1
CL
R_
LR
DR
_M
CF
_P
LU
M B_
A F
-1
- 3
-0
1/8" = 1'-0"P-900123B
1 PLUMBING DOMESTIC WATER AND COMPRESSED AIR FLOOR PLAN C
GENERAL NOTES:
A. FOR GENERAL PLUMBING LEGEND AND
SYMBOLS, SEE SHEET P-900001B.
B. FOR CONTINUATION OF UTILITIES, SEE
CIVIL ENGINEER'S DRAWINGS.
C. SEE MECHANICAL DRAWINGS FOR
EXACT LOCATION AND MORE INFORMATION
FOR MECHANICAL UNITS.
D. REFER TO SHEET A-900008B FOR HEMP
SHIELD.
E. FACULTY COMPRESSED AIR SYSTEM
DESIGN IS TO PROVIDE OIL FACE SUPPLY
LOOP. OIL LUBRICATOR IF REQUIRED AT ANY
TOOL(S) AND EQUIPMENT SHALL BE
PROVIDED BY USER.
KEYNOTES:
1/2"CA W/ S.O.V. INSIDE THE HEMP
TO HEMP DOOR CONTROLLER.
1"CW & 1-1/2"ICW W/ S.O.V FOR
RADAR PRIME CONNECTION.
PLAN NORTH
SCALE:
0 8' 16'
1/8" = 1' - 0"
8' 16'
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUTS/NOTES ARE INCHES UNLESS OTHERWISE NOTED
REFER TO DIAGRAM ON P-900605B
FOR PIPING AND
INSTRUMENTATION REQUIREMENT.
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.1
B T
N
9 9
H
I
J
K
K.5
L
M
N
O
7 8 9 10 11 12 13 14
MAIN ELEC ROOM
MECH ROOM 3
JAN STOR
LOCKERS 1
LOBBY
LOCKERS 2
WOMEN'S ROOM
MEN'S ROOM
MEN'S SHOWER
ELEC ROOM 2
OPEN OFFICE
GOV USER
QA/CM MANAGER
LRDR MANAGER
CO OFFICE
XO OFFICE
CO OFFICE
TECH LIBRARY
BREAK ROOM
WATER
TREATMENT
WEATHER
VESTIBULE
HEMP VESTIBULE
P-900401B
1"ICW
2-1/2"CW
1"ICW
2-1/2"CW
2-1/2"CW
2"ICW3/4"CW
S-90012001
3/4"HW
2"CW TO MF & ECF BLDG.
CAPPED FOR FUTURE
4"RW FROM DOMESTIC
WATER WELL.
CLEAN AGENT
PARTS STORAGE
COMM CMC
CORR
PIPE ENTRY 1A
CLOSET
COPY/ RECYCLE
WOMEN'S
SHOWER
MECH ROOM 2
CVTC CONF
1/2"CW
IMB-90012001
3/4"ICW DN. TO
CRAC-90041003B,
SEE MECH DWGS.
3/4" ICW DN. TO
CRAC-90041002B,
CRAC-90041002A,
SEE MECH DWGS.
S.O.V.
2"CW FOR LPP ONLY
1"ICW FOR LPP ONLY
BATTERY ROOM
PIPE ENTRY 1B
CORR
CORR
3/4"HWR
3/4"HWR
3/4"HWR
3/4"HWR
3/4"CA
1-1/2"CA
3/4"ICW7
1"ICW7
3/4"ICW7
1"ICW
ABV CEILING
1-1/2"CA
P900402 .2
SEE SHEET P900122B
S E
E S
H E
E T
P B
P-900402B
3/4"CA
2"RCW FR MF & ECF BLDG.
CAPPED FOR FUTURE
1/2"CA
1/2"CA
IE= -5' - 7" BFF
P-900503B
P-900505B
1-1/2"ICW TO LES
1"CW TO LES
IE= -5' - 6" BFF
IE= -5' - 6" BFF
3/4" ICW TO
CRAC-90041003A,
SEE MECH DWGS.
2-1/2" CW
3/4" HW
3/4" HWR
1-1/2" CW
1"ICW
3"CW 1"CW
2"CW
1-1/2"ICW
1"ICW
3/4"HWR
3/4"HW
C P
-B
C P
-E
CP1-B
CP1-A
P900401 2
P900403 .2
P900406 2
MDCR
EOC
P900404 2
A B
C D
E
LES
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/1
/2
:3 :3
P
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
P
L U
M B c h e ls e a .d e c a s tr o .r v t
RTA P-900124B
P L U
M B
IN
G
D O
M E
S T
I C W
A T
E R
A N
D C
O M
P R
E S
S E
D A
IR
F
L O
O R
P L A
N D
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P .W
U
K .M
A Y
O R
K .M
A Y
O R
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
:1
CL
R_
LR
DR
_M
CF
_P
LU
M B_
A F
-1
- 3
-0
1/8" = 1'-0"P-900124B
1 PLUMBING DOMESTIC WATER AND COMPRESSED AIR FLOOR PLAN D
GENERAL NOTES:
A. FOR GENERAL PLUMBING LEGEND AND
SYMBOLS, SEE SHEET P-900001B.
B. FOR CONTINUATION OF UTILITIES, SEE
CIVIL ENGINEER'S DRAWINGS.
C. SEE MECHANICAL DRAWINGS FOR
EXACT LOCATION AND MORE INFORMATION
FOR MECHANICAL UNITS.
D. REFER TO SHEET A-900008B FOR HEMP
SHIELD.
E. FACULTY COMPRESSED AIR SYSTEM DESIGN
IS TO PROVIDE OIL FACE SUPPLY LOOP. OIL
LUBRICATOR IF REQUIRED AT ANY TOOL(S) AND
EQUIPMENT SHALL BE PROVIDED BY USER.
KEYNOTES:
1/2"CA W/ S.O.V. INSIDE THE HEMP
TO HEMP DOOR CONTROLLER.
HEMP PENETRATION.
NOT USED.3
NOT USED.4
NOT USED.5
1"ICW DOWN ALONG COLUMN
INTO RECESSED FLOOR SPACE.
BELOW FLOOR TILE IN
RECESSED FLOOR SPACE.
PLAN NORTH
SCALE:
0 8' 16'
1/8" = 1' - 0"
8' 16'
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUTS/NOTES ARE INCHES UNLESS OTHERWISE NOTED
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.1
B T
N
R E
F
FD
O
2"
2"
2"
BFP-90012004
1" ICW TO MCF
3" CW TO MCF
BFP-90012001
BFP-90012002
BFP-90012003
4"
4"
4"
WM-90012001
1"3"
3"
WM-90012002
4" RAW WATER
2" CW SUPPLY
TO MCF & EF
WM-90012003
2" CW TO LPP
1" CW TO LES
1" ICW TO LPP
1-1/2" ICW TO LES
P-900501B
4" 4"
TP-90012001
1/2"TP
1/2"TP
1/2"TP
1/2"TP
1" WWC
1-1/2"WWC
1"WWC
2"WWC
2" RCW FROM
MCF & EF
CHECK VALVE
ES-90012002
FS-90017001
FS-90017002
FS-90017001
FS-90017001
IMB-90012001
3/4"
3/4"
3/4"
1/2"CW W/ S.O.V
TO COFFEEMAKER
FS-90017001
S-90012001
HB-90012002
PRV-90012001
(SET @ 115 PSI)
3/4"CW
3/4"HW
3/4"HWR
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/1
/2
:3 :3
P
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
P
L U
M B c h e ls e a .d e c a s tr o .r v t
RTA P-900402B
P L U
M B
IN
G
E N
L A
R G
E D
F L O
O R
P L A
N S
S
H E
E T
O
F
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P .W
U
K .M
A Y
O R
K .M
A Y
O R
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
:1
CL
R_
LR
DR
_M
CF
_P
LU
M B_
A F
-1
- 3
-0
1/4" = 1'-0"P-900402B
1 ENLARGED WATER TREATMENT ROOM WATER PLAN
PLAN NORTH
SCALE:
0 4' 8'
1/4" = 1' - 0"
4' 8'
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUTS/NOTES ARE INCHES UNLESS OTHERWISE NOTED
FCU-90041002
GENERAL NOTES:
A. FOR GENERAL PLUMBING LEGEND AND
SYMBOLS, SEE SHEET P-900001B.
B. FOR CONTINUATION OF UTILITIES, SEE
CIVIL ENGINEER'S DRAWINGS.
C. SEE MECHANICAL DRAWINGS FOR
EXACT LOCATION AND MORE INFORMATION
FOR MECHANICAL UNITS.
D. SEE DETAIL 7, SHEET P-900503B FOR
SCHEMATIC DIAGRAM OF THE WATER
TREATMENT PIPING LAYOUT.
E. REFER TO SHEET A-900008B FOR HEMP
SHIELD.
KEYNOTES:
P.O.C. 4" COLD WATER TO WATER
TREATMENT SYSTEM. FOR CONTINUATION
SEE SHEET D-900103B.
PROVIDE DRAIN PAN UNDERNEATH THE
OVERHEAD WATER PIPES. DRAIN SHALL
SPILL THRU WALL AND TERMINATE
OUTSIDE THE BUILDING.
P.O.C. 2" CW TO SITE AND 2" CW FROM
SITE RECIRCULATION SYSTEM. SEE
MECHANICAL DRAWINGS FOR
CONTINUATION.
P.O.C. 4" WWC. SEE MECHANICAL
DRAWINGS FOR CONTINUATION.
HEMP PENETRATION.5
AECOM
700 G Street, Suite 500
Anchorage, Alaska 99501
907.562.3366 | AECC280
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.1
B T
N
FLOOR LEVEL
TO ECF/MF
RAW WATER
BFP-90012001
WATER TREATMENT
EQUIPMENT
WATER METER (TYP)
FLOOR LEVEL
CRAC-90041003B CRAC-90041002A CRAC-90041002B CRAC-90041003A CRAC-90041001A CRAC-90041001B 01-MP900604B 01-MP900601B 02-MP900601B 03-MP900601B 06-MP900601B 05-MP900601B 04-MP900601B
01-D900103B 02-D900103B
IC
W
COFFEE
MAKER HB-90012001 ES-90012002 S-90012002 ES-90012002
3" CW
2-1/2" CW
1-1/2" CW
2-1/2" CW
C P
-B
C P
-C
"C
W
C P
-B
C P
-C
HEMP SHIELD
ROOF
LEVEL
-1
/2
IC
W
"C
W
C P
-B
R A
D A
R
C P
-B
R A
D A
R
HEMP SHIELD
ROOF
LEVEL
M A
T C
H L
IN
E
M A
T C
H L
IN
E
1" ICW
1" ICW
IWH-90012002
ES-90012001
07-MP900601B
2" WWC
CRAC-90041004BCRAC-90041004A
01-MP900602B
BFP-90012005
BFP-90012003 BFP-90012004BFP-90012002
"I
C W
1" ICW
1-1/2" ICW
1" ICW
FROM ECF/MF
01-MP900607B
02-MP900607B
01-P900603B
02-P900603B
/4
IC
W
/4
IC
W
/4
IC
W
S-90012001
IMB-90012001
HB-90012002
1" ICW
CRAC-90041001C
PRV-90012001
1" ICW 1" ICW
1" ICW
M M M
ES-90012002
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/1
/2
:3 :3
P
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
P
L U
M B c h e ls e a .d e c a s tr o .r v t
RTA P-900606B
W A
T E
R P
IP
IN
G D
IA
G
R A
M
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P .W
U
K .M
A Y
O R
K .M
A Y
O R
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
:1
CL
R_
LR
DR
_M
CF
_P
LU
M B_
A F
-1
- 3
-0
NTSP-900606B
1 WATER PIPING DIAGRAM
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUTS/NOTES ARE INCHES UNLESS OTHERWISE NOTED
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.1
B T
N
9 9
HEMP SHIELD
FLOOR
M A
T C
H L
IN
E
M A
T C
H L
IN
E
HEMP SHIELD
FLOOR
8" S
4" S
4" S
4" FCO
FD-90017003 FD-90017003
4" FCO
4" FCO
FD-90017002
FD-90017002
FD-90017002
FD-90017002
FS-90017001FS-90017002
4" S
FD-90017003
FCO-90017002
6" S
FD-90017003
4"FCO
4" S
PULL BOX4" FCO
4" FCO
4" S
8" S
4" S
4" FCO PULL BOX
C P
-B
R A
D A
R
P900104 P900304 P900305
P900302 P900303P900101P900106
P900105
P900112
P900203
P900201
P900204
P900207
FD-90017002
4" FCO
P900206
P900212
P900213
P900214
STANDPIPE
DRAIN
S-90012001
ES-90012002
FD-900170024"S
FD-90017002
4" FCO
PULLBOXES
4" FCO
P900205
TD-90017001
P900210 P900209
HEMP SHIELD
ROOF
H E
M P
S H
IE
L D
H E
M P
S H
IE
L D
FD-90017002
P900211
2"V
2"V
2"V
3"V
4"VTR
P900503
"V
SEE ENLARGED
TOILET ROOM
ISOMETRIC
DIAGRAMS
4" FCO
FS-90017001
S-90012001
4" FCO4" FCO
FS-90017001
ES-90012002FS-90017001
COTG
6"S
2"V FROM BACKWASH
DRAIN
3"V
3"V
FIRE PUMP
ROOM DRAIN
FIRE PUMP
PIT DRAIN
2"V FROM
FIRE PUMP RM
3"V, SEE P-900601B
FOR CONTINUATION
3"V
HEMP SHIELD
ROOF
2"V, SEE P-900601B
FOR CONTINUATION3"V
P9002023 "V
3"V, SEE P-900601B
FOR CONTINUATION
WELL PUMP DRAIN
WELL PUMP
DRAIN
3"V
P900307
3"V 3"V
2"V
4"VTR
P900505
"V
2"V FR LES LINK
FLOOR DRAIN
SEE P-900601B FOR
CONTINUATION OF
LES LINK VENT
3"V
2"V
P900102
P900103
FD-90017003
3"V
3"V
SEE P-900601B FOR
CONTINUATION OF WELL
PUMP DRAIN VENT
"V
SEE P-900601B FOR
CONTINUATION AIR
COMPRESSOR DRAIN VENT
SEE THIS SHEET FOR CVTC
CONF DRAIN VENT
CONTINUATION
3"V FR CVTC CONF
DRAIN VENT
3"V
"V
2" S
6" S
8" S
ES-90012002
P900111
3"V, SEE P-900601B
FOR CONTINUATION
3"V
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/1
/2
:3 :4
P
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
P
L U
M B c h e ls e a .d e c a s tr o .r v t
RTA P-900607B
P L U
M B
IN
G
W A
S T
E D
IA
G
R A
M
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P W
U
K M
A Y
O R
K M
A Y
O R
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
:1
CL
R_
LR
DR
_M
CF
_P
LU
M B_
A F
-1
- 3
-0
NTSP-900607B
1 SANITARY WASTE/VENT DIAGRAM
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.1
B T
N
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/1
/2
:3 :4
P
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
P
L U
M B c h e ls e a .d e c a s tr o .r v t
RTA P-900701B
P L U
M B
IN
G
F
IX
T U
R E
S C
H E
D U
L E
S
S H
E E
T
O F
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P .W
U
K .M
A Y
O R
K .M
A Y
O R
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
:1
CL
R_
LR
DR
_M
CF
_P
LU
M B_
A F
-1
- 3
-0
------1"--BFP-90012002 REDUCED PRESSURE PRINCIPLE ASSEMBLY, CAST-IRON BODY, LEAD-FREE
BACKFLOW
PREVENTER
------4"--BFP-90012001 REDUCED PRESSURE PRINCIPLE ASSEMBLY, CAST-IRON BODY, LEAD-FREE
BACKFLOW
PREVENTER
2"2"2"----FD-90017002 HEAVY DUTY CAST IRON BODY, FLASHING COLLAR, ADJUSTABLE TOP, NICKEL BRONZE ROUND STRAINER. COMPLETE WITH "PROSET SYSTEMS" (OR EQUAL) TRAP SEAL DEVICE.FLOOR DRAIN
2"2"2"1/2"TP--FD-90017001 HEAVY DUTY CAST IRON BODY, FLASHING COLLAR, ADJUSTABLE TOP, NICKEL BRONZE ROUND STRAINER, AND WITH TRAP PRIMER CONNECTION.FLOOR DRAIN
2"2"2"1/2"--EWC-90012001
SELF-CONTAINED, HEAVY-DUTY, VANDAL RESISTANT BUBBLER HEADS, 14 GAUGE STAINLESS STEEL CABINET WITH FRONT ACCESS PANEL AND INTEGRAL BASIN, FRONT SELF- CLOSING PUSH BUTTON ACTIVATION WITH BOTTLE FILLER. UNIT SHALL MEET ADA GUIDELINES AND CERTIFIED TO NSF/ANSI 61. 115V / 60 Hz / 370 WATTS / 4.0 F.L.AMPS. (BASIS OF
DESIGN: ELKAY MODEL NO. LVRCHDTL8SC WITH BOTTLE FILLER)
ELECTRIC WATER
COOLER
2"3"3"3/4"3/4"SS-90012001
MOP SINK, CORNER FLOOR MOUNTED, COMPLETE WITH WALL MOUNTED FAUCET WITH VACUUM BREAKER, TRAP, VINYL GUARD LONG NECK SPOUT WITH SUPPORT
BRACKET, PALE HOOK.
SERVICE
SINK
------1/2"--IMB-90012001 POWDER COATED METAL BOX; 1/4 TURN BRASS BALL VALVE WITH WATER HAMMER ARRESTER.
ICE MACHINE
BOX
1-1/2"2"1-1/4" 1-1/4"
TW--
------1/2"--
------1-1/2"1-1/2"
ES-90012001
WHA-90012001
MV-90012001
TP-90012001
SH-90012001
UR-90012002
UR-90012001
WC-90012002
S-90012001
L-90012001
WC-90012001
MARK
COMBINATION DRENCH SHOWER AND EYE/FACE WASH, PLASTIC SHOWER HEAD AND BOWL WITH DUST COVER. COMPLETE WITH FLOOR DRAIN, ALARM, LIGHTING AND MONITOR.
EMERGENCY
EYEWASH/
SHOWER
PISTON TYPE, SHALL BE INSTALLED BEHIND ACCESS PANEL. SIZE SHALL BE SELECTED BY CONTRACTOR BASED ON CONNECTED DRAINAGE FIXTURE UNITS IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
WATER HAMMER
ARRESTER
------1/2"--
SHALL BE INSTALLED BEHIND ACCESS PANEL AND SHALL BE PROVIDED WITH DISTRIBUTION UNIT AS NEEDED TO SERVE UP TO FOUR FLOOR DRAINS
AND/OR FLOOR SINKS.
RECIRCULATION STATION CONSISTING OF HIGH-LOW THERMOSTATIC MIXING VALVE IN COMBINATION WITH PIPING ASSEMBLY, INLET/OUTLET SHUTOFF VALVES, PRESSURE/TEMPERATURE GAUGES, CIRCULATING PUMP, CIRCUIT SETTER BALANCING VALVE AND GFCI ELECTRICAL OUTLET. ALL COMPONENTS PRE-ASSEMBLED TO
ENAMEL COATED STRUT AND TESTED BY MANUFACTURER. HIGH-LOW THERMOSTATIC MIXING VALVE ASSEMBLY SHALL HAVE A LIQUID-FILLED THERMOSTAT AND
STAINLESS STEEL PISTON AND LINER ASSEMBLY, BRONZE BODY AND CAP WITH REPLACEABLE CORROSION RESISTANT COMPONENTS, WITH INTEGRAL CHECKSTOPS, REMOVABLE STRAINERS AND THERMOMETER. 1-1/2" INLETS & 1-1/2" OUTLET AND 3/4" RETURN LINE, 1.5 GPM MIN FLOW
CAPACITY, 17.0 GPM MAX FLOW CAPACITY AT 10 PSI PRESSURE DROP SET AT 120°F OUTLET TEMPERATURE.
TRAP PRIMER
(PRESSURE)
THERMOSTATIC
MIXING VALVE
MOLDED REINFORCED FIBERGLASS SHOWER ENCLOSURE WITH AN OUTSIDE DIMENSION OF 62"X33"X78-3/4" (1)36” 18 GAUGE STAINLESS STEEL GRAB BAR ON THE BACK WALL, (1) 24” 18 GAUGE STAINLESS STEEL GRAB BAR ON THE SIDE WALL, BOTH W/ 1-1/2” STATUTE CLEARANCE, SECURED FROM THE REAR W/ STAINLESS STEEL BOLTS AND 3”X3”X11 GAUGE METAL MOUNTING PLATES, 26”X21” FRAMELESS WOOD GRAIN PHENOLIC FOLD-UP SEAT, MOLDED CORNER SOAP LEDGES, 18 GAUGE STAINLESS STEEL CURTAIN ROD W/ RECEIVER DUPS, TRI CELL BACKING, SELF SUSTAINING BOTTOM AND ¾” THRESHOLD. COMPLETE W/ ACCESSIBLE SHOWER SYSTEM WITH PRESSURE-BALANCING MIXING VALVE WITH LEVER HANDLE, INTEGRAL SERVICE STOPS AND ADJUSTABLE STOP SCREW TO LIMIT HANDLE TURN, CAST BRASS ADJUSTABLE SPRAY 1.5 GPM SHOWER HEAD WITH ARM AND FLANGE, DUAL OUTLET LEVETROL DIVERTER VALVE WITH WALL/HAND SHOWER WITH 5-FOOT FLEXIBLE METAL HOSE IN-LINE VACUUM BREAKER AND WALL CONNECTION, 30-INCH SLIDE BAR FOR MOUNTING HAND SHOWER
SHOWER
ACCESSIBLE 2"2"2"3/4"3/4"
URINAL 1-1/2"2"INT3/4"--
URINAL 1-1/2"2"INT3/4"--
WALL MOUNTED, HIGH-EFFICIENCY, WHITE VITREOUS CHINA WITH WASHOUT FLUSHING ACTION AND TOP SPUD WATER CONNECTION. COMPLETE WITH HIGH-EFFICIENCY DIAPHRAGM-
TYPE FLUSH VALVE (1/8 GPF) & FLOOR MOUNTED CONCEALED URINAL CARRIER.
WATER
CLOSET
2"4"INT1"--
WALL MOUNTED, SIPHON JET, ELONGATED BOWL, WHITE VITREOUS CHINA. COMPLETE WITH DIAPHRAGM-TYPE FLUSH VALVE (1.28 GPF), HEAVY-DUTY SOLID PLASTIC WHITE
ELONGATED OPEN FRONT SEAT LESS COVER WITH STAINLESS STEEL SELF-SUSTAINING HINGE & HORIZONTAL OR VERTICAL ADJUSTABLE CONCEALED WATER CLOSET
CARRIER. MOUNT AT ACCESSIBLE HEIGHT.
WATER
CLOSET
22"X22", UNDERMOUNT SINGLE BOWL, 6-1/2" DEEP, MOUNT AT ADA HEIGHT, 18 GAUGE STAINLESS STEEL, EACH BASIN SINGLE DRAIN HOLE PUNCHED, SINGLE LEVER
FAUCET WITH (1.0 GPM) AERATOR. COMPLETE WITH GARBAGE DISPOSER, 3/4 HP, 120V, 1 PH, 60 HZ.
SINK
(BREAKROOM) 1-1/2"2"1-1/2"3/4"3/4"
COUNTERTOP LAVATORY, SEE SPECIFICATION 06 61 16.01 00 FOR LAVATOR INFORMATION, COMPLETE WITH METERED FAUCET SET @ 15 SECONDS WITH 0.35 GPM AERATOR AND
VANDAL RESISTANT COVER PLATE , 1-1/4" OUTLET OPEN GRID P.O. PLUG, SEAMLESS PRE-WRAPPED 1-1/4" L.A. PATTERN P-TRAP WITH GALVANIZED NIPPLE, CHROMIUM PLATED
BRASS CASING, LOOSE KEY STOPS WITH RIGID SUPPLIES, SEAMLESS SUPPLY RISER TUBE COVERS AND ANGLE STOP WHEEL HANDLE COVERS.
LAVATORY 1-1/2"2"1-1/4"1/2"1/2"
2"4"INT1"--
WALL MOUNTED, SIPHON JET, ELONGATED BOWL, WHITE VITREOUS CHINA. COMPLETE WITH DIAPHRAGM-TYPE FLUSH VALVE (1.28 GPF), HEAVY-DUTY SOLID PLASTIC WHITE
ELONGATED OPEN FRONT SEAT LESS COVER WITH STAINLESS STEEL SELF-SUSTAINING HINGE & HORIZONTAL OR VERTICAL ADJUSTABLE CONCEALED WATER CLOSET
CARRIER.
DESCRIPTION
VENTWASTETRAPCOLDHOT
SANITARYWATER
TYPE
PLUMBING FIXTURE SCHEDULE
2"4"4"----FD-90017003 HEAVY DUTY CAST IRON BODY, FLASHING COLLAR, ADJUSTABLE TOP, NICKEL BRONZE ROUND STRAINER. COMPLETE WITH "PROSET SYSTEMS" (OR EQUAL) TRAP SEAL DEVICE.FLOOR DRAIN
ES-90012002 EYE/FACE WASH, BOWL AND DUSTCOVER, BARRIER-FREE WALL MOUNTED. PROVIDED WITH EMERGENCY THERMOSTATIC MIXING VALVE.
EMERGENCY
EYEWASH
1-1/2"2"1-1/4"
3/4"
TW
S-90012002 SINK - WALL HUNG - 18 GAUGE STAINLESS STEEL - ADA COMPLIANT - EACH BASIN SINGLE DRAIN HOLE PUNCHED, SINGLE LEVER FAUCET WITH (1.0 GPM) AERATOR.
SINK
(MAINTENANCE
SHOP)
1-1/2"2"1-1/2"3/4"3/4"
*NOTE: ALL DIMENSIONS
AND/OR DIMENSIONS SHOWN
IN CALLOUTS/NOTES ARE
INCHES UNLESS OTHERWISE
NOTED
WALL MOUNTED, HIGH-EFFICIENCY, WHITE VITREOUS CHINA WITH WASHOUT FLUSHING ACTION AND TOP SPUD WATER CONNECTION. COMPLETE WITH HIGH-EFFICIENCY DIAPHRAGM- TYPE FLUSH VALVE (1/8 GPF) & FLOOR MOUNTED CONCEALED URINAL CARRIER. MOUNT AT ACCESSIBLE HEIGHT.
BFP-90012003 REDUCED PRESSURE PRINCIPLE ASSEMBLY, CAST-IRON BODY, LEAD-FREE
BACKFLOW
PREVENTER
BFP-90012004 REDUCED PRESSURE PRINCIPLE ASSEMBLY, CAST-IRON BODY, LEAD-FREE
BACKFLOW
PREVENTER
------1-1/2"--
------1"--
BFP-90012005 REDUCED PRESSURE PRINCIPLE ASSEMBLY, CAST-IRON BODY, LEAD-FREE
BACKFLOW
PREVENTER ------2"--
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.1
B T
N
| Plumbing Amendment 9 - Sheet - P-900121B |
| Plumbing Amendment 9 - Sheet - P-900122B |
| Plumbing Amendment 9 - Sheet - P-900123B |