CLR_LRDR_LSUB_M-907503H_-_AM10.PDF

PDF 86 KB Posted

Attached to
LRDR CP#1 Site Infrastructure, MCF, and Substation (CLR039a), Clear AFS, Alaska
Solicitation number
W911KB-17-R-0010
Issued by

About this file

M-907503H

View the file

Other files

File Type Posted
J&A_17-2_Edwards_EST3_Fire_Panel_Redacted.pdf PDF
J&A_Intrusion_Detection-Vindicator_Redacted.pdf PDF
J&A_Siemans_Apogee_BACnet_Redacted.pdf PDF
W911KB-17-R-0010_AM_14.pdf PDF
W911KB-17-R-0010_AM_13.pdf PDF
W911KB-17-R-0010_AM_12.pdf PDF
13_27_54.01_10_AM_11.pdf PDF
Bidder_Inquiry_Report_W911KB-17-R-0010.pdf PDF
33_20_00.01_00_AM_11.pdf PDF
31_00_00.01_00_AM_11_17y01m25d.pdf PDF
W911KB-17-R-0010_AM_11.pdf PDF
07_42_63.01_00_AM_10.pdf PDF
CLR_LRDR_MCF_S-900549B_AM_10.pdf PDF
09_97_13.01_17.pdf PDF
Mechanical_Amendment_10_-_Sheet_-_MP900402B.PDF PDF
M-100601A_-_SYSTEM_DIAGRAMS_-TEMPORARY_FUEL_TANK.pdf PDF
Mechanical_Amendment_10_-_Sheet_-_MP900401B.PDF PDF
01_50_00.01_00.pdf PDF
33_52_80.01_00.pdf PDF
09_97_13.01_27.pdf PDF
M-100502A_-_DETAILS_-_TEMPORARY_FUEL_TANK.pdf PDF
01_91_19.01_00_Amendment_10.pdf PDF
CLR_LRDR_LSUB_M-907600H_-_AM10.PDF PDF
08_34_49.01_20_AM_10_(2).pdf PDF
Mechanical_Amendment_10_-_Sheet_-_MP900601B.PDF PDF
A-900005B_AM_10.pdf PDF
01_91_00.01_15_attachment_1_-_170123_LRDR_draft_CP-1_Cx_Master_Equipment_List.pdf PDF
CLR_LRDR_MCF_Z-900001B_AM_10.pdf PDF
W911KB-17-R-0010_AM_10.pdf PDF
33_52_10.01_00_-_AM10.pdf PDF
01_91_00.01_15_Amendment_10.pdf PDF
M-100301A_-_SECTIONS_-_TEMPORARY_FUEL_TANK.pdf PDF
A-900005B_AM_9.pdf PDF
23_05_93.01_00_AM_9.pdf PDF
06_20_00.01_00_AM_9.pdf PDF
22_05_48.00_20_AM_9.pdf PDF
Mechanical_Amendment_9_-_Sheet_-_MH900902B.pdf PDF
Revised_Plumbing_Sheets_-_Inquiry__6793897.pdf PDF
Mechanical_Amendment_9_-_Sheet_-_MP900703B.pdf PDF
26_08_01.01_00.pdf PDF
T-100601A_AM_09.pdf PDF
23_09_23.01_29_AM_9.pdf PDF
W911KB-17-R-0010_AM_9.pdf PDF
22_00_00.01_00_AM_9.pdf PDF
27_08_00.01_00.pdf PDF
33_20_01.01_00.pdf PDF
33_11_00.01_00_AM_9_17y01m18d.pdf PDF
09_97_13.01_17.pdf PDF
28_08_00.01_00.pdf PDF
E-100301A_Amendment__009.pdf PDF
Show 40 more

Latest 50 of 128 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

17" O.D., 7.0 GALLON SPILL

CONTAINER THREADED ONTO

3" PIPE WITH INTEGRAL DRAIN

VALVE

3" FILL TUBE

OVERFILL PREVENTION VALVE SHUT OFF

PUMPED FUEL FLOW AT 95% TANK LEVEL

DROP TUBE

TANK SHELL

HINGED LOCKABLE COVER

3" TRUCK UNLOADING QUICK

DISCONNECT DRY-BREAK COUPLER

WITH DUST CAP

NOTES 1

NOTE:

1. PROVIDE UNPAINTED GROUNDING STUD.

6" 6"

1/2"

3/8"

UNION PSV

(SEE NOTE A)

FOS, FOM

(SEE NOTE A)

DIRECTION OF RELIEF

TO STORAGE TANKS

BALL OR PLUG

VALVE

(AS INDICATED)

NOTES:

A. VALVE SHALL HAVE REMOVABLE

HANDLE.

NO NO

"D"

M

IN

"A" "B" "C" "D" "E"

2 1/2" 2 1/2" 2"

BASE PLATE

"F"

1/8" GAPPIPE DIA

1/4

"C" ø CONCRETE

ANCHOR (TYP)

"G" MIN

EMBEDMENT

3/4" GROUT

3/4" 1/2"

"G"

12" 3 1/4"

BASE PLATE "F"

THICKNESS

C PROCESS PIPE

PIPE STANCHION

STEEL

SADDLE w/U-BOLT

ADJUSTABLE NIPPLE (A53 A OR B)

FORGED STEEL ADAPTER

"C" + 1/16" DIAMETER HOLE

(TYP)

PROCESS

PIPE DIA

9 1/2"

PIPE STANCHION "A" (A53 A OR B)

"E" (TYP)

(TYP)

"B"

L

PIPE FLANGE, TYP

FF

ROTARY PUMP

BALL VALVE, TYP.

PRIMING TEECONTROL

PANEL

10 MICRON FILTER

1 MICRON

ELEMENT & WATER

SEPARATOR

SITE GLASS

SWITCH GAUGE PANEL

WIRE MESH STRAINER

WALL PANEL ENCLOSURE

LEAK DETECTOR

1" FOS

1" FOR

3 MICRON FILTER

D E

P

A R

T M

E N

T O

F D

E F

E

N S

E

MISSIL

E D

E F

E N

S E

A

G

ENCY

D ra w in g

F ile

N a m e

D w g S c a le

P lo t S c a le

D a te

D ra w n

R E

S

ID

E N

T E

N G

IN

E

E R

P R

IM

E

C O

N T

R A

C T

O R

S u b m it te d

D e s ig n e d

R e v ie w e d

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

A N

C H

O R

A G

E A

L A

S K

A

C O

R P

S O

F E

N G

IN

E

E R

S

D a te

S T

A T

E C

IT

Y

C O

N T

R A

C T

O R

C O

N T

R A

C T

N O

R e c o m m e n d e d

A p p ro v e d

Reference number:

HGFEDCBA

A S

N O

T E

D

P L O

T T

E D

O N

US Army Corps of Engineers ®

Alaska District

M D

A

C L R a

N O

T F

O R

C O

N S

T R

U C

T

IO

N

A F

-1

- 3

-0

A S

N O

T E

D

:1

C

LR

_L R

D R

_L

SU

B_ M

-D M

B L A

C K

V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P W

T

H S

T

S U

IT

E

O V

E R

L A

N D

P A

R K

K

S

.4

.2

B

V S

P C

J R

H

.1

.1

C O

N S

T R

U C

T

IO

N

P

A C

K A

G E

V O

L U

M E

/2

/2

:3 :3

P

M C

P ro g ra m D a ta

\A u to d e s k \R

V T

\U s e rD a ta

C a c h e \C

L R

L R

D R

L S

U B

M

-D M m c k .r v t

RTA M-907503H

D E

T A

IL

S

S

U B

S T

A T

IO

N

F U

E L

T A

N K

S H

E E

T

L O

N G

R A

N G

E D

IS

C

R

IM

IN

A

T

IO

N R

A D

A R

C L

E A

R A

F S

A

L A

S K

A

R R

M

M S

A

K L H

W K

B -1

-R

-0

C L R

L R

D R

M

-9 H

SCALE:

DETAIL

NTSM-907503H

FUEL FILL ASSEMBLY

SCALE:

DETAIL

NTSM-907503H

FUEL OIL THERMAL RELIEF PIPING

SCALE:

DETAIL

NTSM-907503H

PIPE STANCHION GUIDE

SCALE:

DETAIL

NTSM-907503H

FUEL POLISHING ENCLOSURE

1. FOR GENERAL NOTES , LEGEND AND ABBREVIATIONS

SEE SHEETS M-907001H THRU M-907004H.

FOR CLARITY, EQUIPMENT TAGS ON THIS

SHEET ARE GENERALLY ABBREVIATED.

UNLESS NOTED OTHERWISE. THE BUILDING

NUMBER (907) MUST BE ADDED TO COMPLETE

EACH TAG.

SHEET NOTES

S y m

A c ti o n

D e s c ri p ti o n

D a te

A p p v d

A M

F L O

W M

E T

E R

R E

M O

V E

D F

R O

M D

E T

A

IL

/2

/1

K L H

CLR_LRDR_LSUB_M-DM2015_mck57888
M-907503H - DETAILS - SUBSTATION FUEL TANK SHEET 3

File details come from the government source that posted it. Updated .