M-100502A_-_DETAILS_-_TEMPORARY_FUEL_TANK.pdf

PDF 63 KB Posted

Attached to
LRDR CP#1 Site Infrastructure, MCF, and Substation (CLR039a), Clear AFS, Alaska
Solicitation number
W911KB-17-R-0010
Issued by

About this file

M-100502A

View the file

Other files

File Type Posted
J&A_17-2_Edwards_EST3_Fire_Panel_Redacted.pdf PDF
J&A_Intrusion_Detection-Vindicator_Redacted.pdf PDF
J&A_Siemans_Apogee_BACnet_Redacted.pdf PDF
W911KB-17-R-0010_AM_14.pdf PDF
W911KB-17-R-0010_AM_13.pdf PDF
W911KB-17-R-0010_AM_12.pdf PDF
13_27_54.01_10_AM_11.pdf PDF
Bidder_Inquiry_Report_W911KB-17-R-0010.pdf PDF
33_20_00.01_00_AM_11.pdf PDF
31_00_00.01_00_AM_11_17y01m25d.pdf PDF
W911KB-17-R-0010_AM_11.pdf PDF
07_42_63.01_00_AM_10.pdf PDF
CLR_LRDR_MCF_S-900549B_AM_10.pdf PDF
09_97_13.01_17.pdf PDF
Mechanical_Amendment_10_-_Sheet_-_MP900402B.PDF PDF
M-100601A_-_SYSTEM_DIAGRAMS_-TEMPORARY_FUEL_TANK.pdf PDF
Mechanical_Amendment_10_-_Sheet_-_MP900401B.PDF PDF
CLR_LRDR_LSUB_M-907503H_-_AM10.PDF PDF
01_50_00.01_00.pdf PDF
33_52_80.01_00.pdf PDF
09_97_13.01_27.pdf PDF
01_91_19.01_00_Amendment_10.pdf PDF
CLR_LRDR_LSUB_M-907600H_-_AM10.PDF PDF
08_34_49.01_20_AM_10_(2).pdf PDF
Mechanical_Amendment_10_-_Sheet_-_MP900601B.PDF PDF
A-900005B_AM_10.pdf PDF
01_91_00.01_15_attachment_1_-_170123_LRDR_draft_CP-1_Cx_Master_Equipment_List.pdf PDF
CLR_LRDR_MCF_Z-900001B_AM_10.pdf PDF
W911KB-17-R-0010_AM_10.pdf PDF
33_52_10.01_00_-_AM10.pdf PDF
01_91_00.01_15_Amendment_10.pdf PDF
M-100301A_-_SECTIONS_-_TEMPORARY_FUEL_TANK.pdf PDF
A-900005B_AM_9.pdf PDF
23_05_93.01_00_AM_9.pdf PDF
06_20_00.01_00_AM_9.pdf PDF
22_05_48.00_20_AM_9.pdf PDF
Mechanical_Amendment_9_-_Sheet_-_MH900902B.pdf PDF
Revised_Plumbing_Sheets_-_Inquiry__6793897.pdf PDF
Mechanical_Amendment_9_-_Sheet_-_MP900703B.pdf PDF
26_08_01.01_00.pdf PDF
T-100601A_AM_09.pdf PDF
23_09_23.01_29_AM_9.pdf PDF
W911KB-17-R-0010_AM_9.pdf PDF
22_00_00.01_00_AM_9.pdf PDF
27_08_00.01_00.pdf PDF
33_20_01.01_00.pdf PDF
33_11_00.01_00_AM_9_17y01m18d.pdf PDF
09_97_13.01_17.pdf PDF
28_08_00.01_00.pdf PDF
E-100301A_Amendment__009.pdf PDF
Show 40 more

Latest 50 of 128 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

17" O.D., 7.5 GALLON

SPILL CONTAINER

THREADED ONTO 3" PIPE

3" FILL TUBE

OVERFILL PREVENTION VALVE. SHUT OFF

PUMPED FUEL FLOW AT 95% TANK LEVEL

DROP TUBE

TANK SHELL

HINGED LOCKABLE COVER

QUICK DISCONNECT

FUEL NOZZLE COUPLER

WITH DUST CAP

NOTES:

1. PROVIDE UNPOINTED GROUNDING STUD

AT PIPE CONNECTION.

BASE PLATE

FUEL PIPE

1/8" GAP

PIPE STANCHION STEEL

SADDLE W/U BOLT

FORGED STEEL ADAPTER

PIPE STANCHION "A" (A53 OR B)

(T

YP

"E

"C" + 1/16" DIAMETER

HOLE, TYP

(TYP)

"D"

" M

IN

3/ 4"

G R

O U

T

"B" ADJUSTABLE NIPPLE (A53 OR B)

EM

BE

D M

EN

T

"G " M

IN

BASE PLATE "F"

THICKNESS

"C ø CONCRETE

ANCHOR, TYP

PIPE DIA

FUEL

PIPE DIA "A"

2-1/2"1/1/4"

"B"

2"

"C"

3/4"

"D"

12"

"E"

9-1/2"

"F"

1/2"

"G"

3-1/4"

1/4

DEPA

R

T M

E N

T O

F D

E F

E

NSE

MISSILE

DE

F E

N S

E

AGENCY

D ra w in g

Fi le

N am e:

D w g Sc al e:

P lo t S ca le

D at e:

D ra w n:

R

ES

I D

EN

T

EN

G

IN

E

ER

P R

IM

E

C O

N

TR

AC

TO

R

S ub m itt ed

D es ig ne d:

R ev ie w ed

U .S

. A R

M Y

E N

G

IN

EE

R

D

IS

TR

IC

T

A N

C H

O R

AG

E, A

LA

SK

A

C O

R

PS

O F

EN

G

IN

EE

R S

D at e:

S

TA

TE

C

IT

Y

C O

N T R

A C

TO

R

C O

N T R

A C

T N

O

R ec om m en de d:

A pp ro ve d:

Reference number:

HGFEDCBA

A S

N O

TE

D

PL

O

TT

ED

O N

US Army Corps of Engineers ®

Alaska District

M D

A6

C

LR

9a

N O

T F O

R C

O N

ST

R

U C

TI

O

N

P D

C

IN

C . E

N G

IN

E E

R S

G

AM

B

EL

L S

T S U

IT

E

A N

C H

O R

AG

E, A K

A

N C

-7

-3

| A

EC

C

1/

/2

1:

:0

PM

C :\U se rs

\m ic ha el ba rte ll\ D oc um en ts

\C

LR

_L R

D R

_F

SV

_M -D

M

_m ic ha el ba rte ll.

rv t

AM #10 M-100502A

D

ET

AI

LS

TE

M

PO

R A R

Y

FU

EL

T

A N K

LO

N

G R

AN

G

E D

IS

C

R

IM

IN

AT

I O N

R A D

AR

C

LE

AR

A

FS

, A

LA

SK

A C he c k er 1:

CL

R_

L R

DR

_F

SV

_M -D

M2

A ut ho r

D es ig ne r

W

1K B-

-R

-0

.1 1.

C O

N

ST

R U

C

TI

O N

P

AC

KA

G

E

- V O

LU

M

E

SM

T

AF

-1

-3

- 0

NOT TO SCALEM-100502A

1 FUEL FILL ASSEMBLY DETAIL

NOT TO SCALEM-100502A

2 PIPE STANCHION GUIDE

GENERAL NOTES

FOR MECHANICAL NOTES, LEGEND, AND

ABBREVIATIONS SEE SHEETS M1000001A, M1000002A,

& M1000003A.

1.

Sy m

A ct io n D es cr ip tio n D at e

A pp vd

A M

A M

M

EN

D M

EN

T

.0 1.

M

JL

Sheets
M-100502A - DETAILS - TEMPORARY FUEL TANK

File details come from the government source that posted it. Updated .