HEAT EXCHANGER SYSTEM
FOR HVAC
CHILLER WATER SYSTEM
HEAT EXCHANGER SYSTEM
FOR EQUIPMENT
COOLING WATER SYSTEM
MODULAR
WATER FILTER
(TYP-2)
24" WWD
24" WWD
24" WWD
DISCHARGE TO STORM
WATER RETENTION BASIN
DISCHARGE TO LAKE
WELL PUMP COOLING TEMP
COLUMN LUBRICATION
3/4" ICW
3/4" ICW
3/4" ICW
3/4" ICW
3/4" ICW
3/4" ICW
12" WWC
W W
C
12" WWC
W W
C
12" WWC
20" WWD
W W
C
W W
C
W W
C
12" WWC
12" WWC
12" WWC
12" WWD
20" WWD (57°F MAX)
W W
C
20" WWC (40°F)
20"
W W
D
W W
C
14"
20"12"
BY RADAR PRIME LOCATED
IN ANTENNA COOLING
ROOM IN MCF
ISOLATION VALVE (TYP)
MAGNETIC FLOW
METER (TYP)
FOR THIS AREA REFER TO
PROCESS "D" SERIES
DRAWINGS
AIR/VACUUM
RELEASE VALVE
(TYP)
AIR/VACUUM
RELEASE VALVE
(TYP)
VARIABLE SPEED
DRIVE (TYP)
VARIABLE SPEED
DRIVE (TYP)
SOV
90016106
SOV
90016105
SOV
90016104
SOV
90016103
SOV
90016102
SOV
90016101
TT
90031102
PDIT
90031002B
PDIT
90031002A
TI
FM
90031001
PI
PI
PI
PI
PI
PI
PI
FOR THIS AREA REFER TO
PROCESS "D" SERIES
DRAWINGS
TT
90031101
HEMP SHIELD
WBC PIPE
MANIFOLD
FM
01-P-900606B
WELL PUMP COOLING TEMP
COLUMN LUBRICATION
WELL PUMP COOLING TEMP
COLUMN LUBRICATION
WELL PUMP COOLING TEMP
COLUMN LUBRICATION
WELL PUMP COOLING TEMP
COLUMN LUBRICATION
WELL PUMP COOLING TEMP
COLUMN LUBRICATION
TO BMS CONTROL SYSTEM
TO BMS CONTROL SYSTEM
TO BMS CONTROL SYSTEM
TO BMS CONTROL SYSTEM
TO BMS CONTROL SYSTEM
TO BMS CONTROL SYSTEM
01-MP900602B
DPT
90031001A
DPT
90031001B
P-90035001A
P-90035001B
P-90035001C
P-90035001D
P-90035001E
P-90035001F
C P
-B
R A
D A
R
C P
-B
C P
-A
C P
-B
C P
-A
C P
-B
R A
D A
R
TT
90031104
TT
90031103
30" WWD
30" WWD
M900101-15
M900116-30
02-MP900602B
MOV
90016101
PT
90016101
2" WWC
W W
C
W W
C
D900006
D900005
D900004
D900003
D900002
D900001
WWF-
90031002
WWF-
90031001
10"
(TYP)
N.C.
N.C.
02-P-900606B
03-P-900606B
04-P-900606B
05-P-900606B
06-P-900606B
07-P-900606B
FM
90035001A
FM
FM
90035001B
FM
GENERAL NOTES:
FOR MECHANICAL PIPING NOTES,
LEGENDS, AND ABBREVIATIONS, SEE
SHEETS M-900001B THRU M-900007B.
A.
KEYNOTES:
REFER TO SPECIFICATION SECTION 43
21 29. 01 00 FOR FLOW METER SIZE.
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/2
/2
:4 :5
A
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
M
E C
H c h e ls e a .d e c a s tr o .r v t
RTA MP900601B
M E
C H
A N
IC
A
L P
IP
IN
G D
IA
G
R A
M
C O
O L
IN
G W
A T
E R
S Y
S T
E M
S
H E
E T
O
F
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P .W
U
:1
C .D
E C
A S
T R
O
N .P
A T
E L
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
CL
R_
LR
DR
_M
CF
_M
EC
H_
A F
-1
-3 -0
NOT TO SCALEMP900601B
1 MECHANICAL PIPING DIAGRAM - COOLING WATER SYSTEM (1 OF 2)
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUTS/NOTES ARE INCHES UNLESS OTHERWISE NOTED
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.2
B T
N
File details come from the government source that posted it. Updated .