B M-100301A
T-10003001
TANK END A
13.3 14
GRADE LEVEL
0"
PIPE WALL PENETRATION,
SEE CP1-B FOR HEMP
PENETRATION DETAIL
PIPE SUPPORTED 18"
ABOVE GRADE, TYP
1 1/4" FOS
SETBACK BETWEEN TANK AND WALL
5' - 0"
MANUFACTURER PROVIDED TANK
ACCESS LADDER AND WALKWAY
4 4
FOS VALVE
1'
0" 1
TRUCKFILL CONNECTION WITH
7.5 GALLON SPILL CONTAINMENT
A M-100301A
I
GRADE LEVEL
0"
1 1/4" FOS
1 1/4" FOR
TANK HAS 1% SLOPE
EMERGENCY VENT 22
TRUCKFILL
CONNECTION WITH
7.5 GALLON SPILL
CONTAINMENT
TANK VENT
36" ID MANHOLE TANK END A
36" ID MANHOLE
TANK END B
TANK INTERIOR
LADDER, TYP
FOS VALVE
TANK END B
TANK END A
1'
0"
DEPA
R
T M
E N
T O
F D
E F
E
NSE
MISSILE
DE
F E
N S
E
AGENCY
D ra w in g
Fi le
N am e:
D w g Sc al e:
P lo t S ca le
D at e:
D ra w n:
R
ES
I D
EN
T
EN
G
IN
E
ER
P R
IM
E
C O
N
TR
AC
TO
R
S ub m itt ed
D es ig ne d:
R ev ie w ed
U .S
. A R
M Y
E N
G
IN
EE
R
D
IS
TR
IC
T
A N
C H
O R
AG
E, A
LA
SK
A
C O
R
PS
O F
EN
G
IN
EE
R S
D at e:
S
TA
TE
C
IT
Y
C O
N T R
A C
TO
R
C O
N T R
A C
T N
O
R ec om m en de d:
A pp ro ve d:
Reference number:
HGFEDCBA
A S
N O
TE
D
PL
O
TT
ED
O N
US Army Corps of Engineers ®
Alaska District
M D
A6
C
LR
9a
N O
T F O
R C
O N
ST
R
U C
TI
O
N
P D
C
IN
C . E
N G
IN
E E
R S
G
AM
B
EL
L S
T S U
IT
E
A N
C H
O R
AG
E, A K
A
N C
-7
-3
| A
EC
C
1/
/2
1:
:2
PM
C :\U se rs
\m ic ha el ba rte ll\ D oc um en ts
\C
LR
_L R
D R
_F
SV
_M -D
M
_m ic ha el ba rte ll.
rv t
AM #10 M-100301A
SE
C
TI
O
N S
- T
EM
PO
R
AR
Y
F U
EL
T
AN
K
LO
N
G R
AN
G
E D
IS
C
R
IM
IN
AT
I O N
R A D
AR
C
LE
AR
A
FS
, A
LA
SK
A R
SW
1:
CL
R_
L R
DR
_F
SV
_M -D
M2
M
EB
M
JL
W
1K B-
-R
-0
.1 1.
C O
N
ST
R U
C
TI
O N
P
AC
KA
G
E
- V O
LU
M
E
SM
T
AF
-1
-3
- 0
1/2" = 1'-0"M-100301A
A TEMPORARY FUEL TANK - SECTION
1/2" = 1'-0"M-100301A
B TEMPORARY FUEL TANK - SECTION
SHEET NOTES
1 TANK SHALL BE SKID MOUNTED AND SUPPORTED SO THAT
THE BOTTOM OF THE TANK IS 12" ABOVE GRADE.
PRIMARY AND EMERGENCY FUEL VENTS SHALL DISCHARGE
TO APPROVED LOCATION, 12 FEET ABOVE GRADE
TANK SUPPORT CONCRETE FOUNDATION PAD. SEE
STRUCTURAL. TANK SHALL BE CONSTRUCTED WITH 1%
SLOPE FROM "A"END TO LOW SIDE AT "B" END.
FOR PIPE SUPPORT DETAIL, SEE 2/M-100502A.
FUEL ALARM PANELS SHALL BE MOUNTED 62" ABOVE GRADE,
TYP.
GENERAL NOTES
FOR MECHANICAL NOTES, LEGEND, AND ABBREVIATIONS
SEE SHEETS M1000001A, M1000002A, & M1000003A.
FOR FUEL SYSTEM DIAGRAM, SEE 1/M100601A.
ALL EQUIPMENT RESTRAINT, SUPPORT, AND ANCHORAGE
TO BE DESIGNED BY THE CONTRACTORS ENGINEER,
UNLESS OTHERWISE NOTED.
FUEL TANKS SHALL BE DESIGNED BY THE CONTRACTORS
ENGINEER.
1.
2.
3.
4.
Sy m
A ct io n D es cr ip tio n D at e
A pp vd
A M
A M
M
EN
D M
EN
T
.0 1.
M
JL
| Sheets |
| M-100301A - SECTIONS - TEMPORARY FUEL TANK |
| M-100502A - DETAILS - TEMPORARY FUEL TANK |
| M-100601A - SYSTEM DIAGRAMS -TEMPORARY FUEL TANK |